01 ZXSDR NodeB Structure and Principle_PPT-45
-
Upload
nnaji-maurice -
Category
Documents
-
view
142 -
download
12
description
Transcript of 01 ZXSDR NodeB Structure and Principle_PPT-45
ZXSDR NodeB Structure and Principle
ZTE University
ZXSDR Overview
B8200 Hardware System Structure
R8840/RSU40 Hardware System Structure
Introduction of SDR 8000 Series Products
Cable Connection and Networking
Content
Main Functions of Node B
Connect with RNC through Iub interface to fulfill the following functions:1. Reporting Node B measurement information
2.Forwarding system information broadcast provided by RNC
3. Performing access control, mobility management, radio resource management, and control command delivered by RNC
Fulfill local environment monitoring
Fulfill radio link transmission with UE at Uu interface
Software Defined Radio (SDR) Base Station
Features of SDR base station:
The 2G-3G base stations share baseband modules.
The 2G-3G base stations share radio frequency
modules.
The 2G-3G base stations share antenna feeder systems.
The 2G-3G base stations share network management.
Software Defined Radio (SDR) Base Station
Based on the SDR platform. It centers on the baseband pool
unit B8200, and consists of
BS8800 series for indoor macro site.
BS8900 series for outdoor macro site.
BS8700 series for flexible distribute.
Module Composition – BaseBand Unit(BBU)
Iub interfacemodule
RRU interface
module
Main control module (CPU)
BBU
Iub interface RRU interface
RNC RRUBaseband
processing
module
Module Composition – Radio Module
Typical Applications of SDR Base Station
Macro base stationLocal coverage
Macro base stationRemote coverage
Micro base stationIndoor coverage
Distributed base stationcoverage
circuitbearer networkcircuit
BBU+RRU System Overview
B8200 Hardware System Structure
R8840/RSU40 Hardware System Structure
Introduction of SDR 8000 Series Products
Cable Connection and Networking
Content
ZXWR B8200 Hardware Structure
Network switching module (FS)
Power module (PM) Baseband processing board (BPC)
Fan module (FA)Control and clock module (CC)
Site alarm module (SA)
ZXWR B8200 Hardware Structure
Mechanical dimensions:
88.4×482.6×197mm (H×W×D)
Weight (full configuration): 8.75kg
Typical power consumption: 75W
Power supply: -48V DC
Temperature range: -15℃~ +50℃
Humidity range: 5% ~ 95%
2U
482.6mm
88.4mm
UL: 192CE
DL: 192CE
HSDPA: 43.2Mbps
HSUPA: 15Mbps
BPC processing
capability
Sector configurations:
WCDMA: 30CS
Baseband capacity: 960CE
Data processing capability:
HSDPA: 216Mbps
HSUPA: 75Mbps
Abis/Iub interface: 2*STM-1; 16*E1/T1; 2*FE/GE
Baseband RF interface: 12*1.25Gbps optical interface
Performance IndicesPerformance Indices
Physical IndicesPhysical Indices
Interface IndicesInterface Indices
ZXWR B8200 Hardware Structure
FP processing
Baseband encoding/ decoding
processing
Baseband modulation/
demodulation
Baseband IQ switch
processing
RF unit
Transmission protocol
processing
Signaling processing Clock module
Operation/maintenance Power moduleExternal power input
ZXWR B8200 Hardware Structure--Cards
Power module (PM): -48VDC power module.
Site alarm board (SA): It provides
eight ways of E1/T1 interfaces,
RS485/232 interfaces,
eight dry contact interfaces (six input interfaces and two dual-
way interfaces).
Control and clock board (CC):
baseband unit controller management
provides self-adaptive Abis/Iub IP interface GE/FE (optical or
electrical interface).
ZXWR B8200 Hardware Structure--Cards
Fiber switch board (FS): to switch IQ signals.
It supports six fiber interfaces
is used for connection with RRU or RSU module.
WCDMA baseband processing board (BPC):
It supports 6CS and uplink or downlink 192CE.
It also supports a 43.2Mbps downlink or 15Mbps uplink data
processing capability.
ZXWR B8200 Hardware Structure--Cards
STM-1 network interface board (NIS): It provides two STM-1
interfaces.
Site alarm extension board (SE): As an extension board of SA, it
provides the same interfaces as the SA board does.
Control & Clock & Switch Board (CC)
Interface Name Description
ETH0 An Ethernet interface that is used between BBU and RNC or BSC. There are two types of ETH0 interfaces on the panel, that is, optical interface and electrical interface (10M/100M/1000M self-adaptive).
ETH1 It is used for BBU cascade, debugging or local maintenance. Ethernet electrical interface (10M/100M/1000M self-adaptive).
EXT An external communication interface that connects with external receivers. It mainly includes 485 and PP1S+/2M+ interfaces.
REF An SMA (F) interface that externally connects with GPS antenna.
Fiber Switch Board (FS)
Interface introduction: Tx0/Rx0 - Tx5/Rx5: It provides the optical interface that
connects with RRU. Board functions: It switches baseband I/Q data. It provides the interface between BBU and RRU.
Baseband processing board (BPC)
BPC fulfills the physical layer protocol and frame protocol specified by 3GPP. It performs such functions as downlink service
data encoding/multiplexing, rate matching, channel mapping, spread scrambling,power weighting, and channel synthesis.
It fulfills RAKE reception and channel decoding of uplink signals.
Baseband processing board (BPC)
It synchronizes radio links and processes transmission frames.
It measures the parameters required for power control and handover.
It has softer handover and diversity reception/transmission functions.
SA Panel Cables
Connect with E1/T1 cable
Connect with RS232 and
RS485 debugging serial
ports
Connect with dry contact signal
cable
Grounding
Connect with SA board panel
socket
Site Alarm Board (SA)
SA Board functions: It supports alarm control and speed control of up to nine fans. It provides signal monitoring and interface lightning protection
for the shelf at which it is located. It provides six input dry contact interfaces and two input/output
dry contact interfaces. It provides eight E1/T1 interfaces.
BBU+RRU System Overview
B8200 Hardware System Structure
R8840/RSU40 Hardware System Structure
Introduction of SDR 8000 Series Products
Cable Connection and Networking
Content
R8840/RSU40 Hardware Structure
The R8840 is a high-power outdoor remote RF unit and the RSU40 is a high-power indoor RF module from ZTE.
R8840/R8860RSU40
R8840/RSU40 Hardware Structure
The R8840 is a high-power outdoor remote RF unit and the RSU40 is a high-power indoor RF module from ZTE.
The R8840 and RSU40 mainly differ in the physical structure.
R RRU 8 WCDMA8 Outdoor 40 40 W
R8840/RSU40 Hardware Structure
Small and light
36
0 m
m320 mm 165 mmZXSDR R8840: outdoor macro RRU
Sector configurations
1C1S to 4C1S
Transmit power: 40 W/60 W
Receive sensitivity
-129.2 dBm@dual antennas
Performance IndicesPerformance Indices
Baseband RF interface: 2 x 1.25 GHz
optical interface
Interface IndicesInterface Indices
Dimensions: 370 mm x 320 mm x 160 mm
Weight: 16.5 Kg
Standard power consumption: 140 W
Power supply: -48 V DC, 220 V AC
Temperature range: -40oC to +55oC
Protection class: IP65
Physical IndicesPhysical Indices
R8840/RSU40 Hardware Structure
Transceiver Unit – RTR
Provides two receiving and one transmitting signal channels.
Amplifies and filters signals and coverts A/D and D/A Retrieves clock reference signals through the Ir
interface and provides clock reference for inner modules
Provides digital intermediate frequency, despiker, and digital predistortion (DPD)
Measures and reports RTWP and TSSI
Transceiver Unit – RTR
Measures and reports VSWR Self-checks and reports hardware failure Monitors the environment Provides tow CPRI ports Inputs external alarms
Power Amplifier Unit – HPA
Amplifies RF signals Reports temperature Provides overcurrent, over temperature, overpower,
and over standing wave protections
Duplex Filter Unit – DFL
Provides transmission/reception combination and dividing/splitting functions for RF signals
Provides transmit/receive RF channel filtering Provides the low noise amplifier (LNA) function Provides transceiver unit with the LNA alarm
reporting function
Power Module – RPW
Power modules can be divided into AC and DC power modules, that is, RPW AC/DC. If AC power supply is used, the RPW AC is configured. If DC power supply is used, the RPW DC is configured. The RPW provides the following functions:
Coverts AC/DC power supply Provides the transceiver unit with undervoltage,
overvoltage, and overcurrent alarms
Ports on the R8840
ANT2Receiver diversity
RF cable port
ANT1Transmit/receive main set
RF cable port
RxInfrequency point extension port
RxOutfrequency point extension port
BBU and RRU portor
cascading RRU port
BBU and RRU portor
cascading RRU port
AISG portAntenna tuning port
Monitoring port Power portAC or DC
Grounding
Ports on the RSU40ANT2
Receiver diversityRF cable port
ANT1Transmit/receive main set
RF cable port
BBU与 RRU的接口
RRU级联接口
BBU and RRU portCascading RRU port
Commission network portRJ45
Frequency point extension port
Test port
Power supply port
External equipment monitoring portDB15 connector
AISG equipment portRET antenna port
BBU+RRU System Overview
B8200 Hardware System Structure
R8840/RSU40 Hardware System Structure
Introduction of SDR 8000 Series Products
Cable Connection and Networking
Content
Indoor SDR Macro BTS in Dual Mode – ZXSDR BS8800
RF layerRF unit configuration
portRSU40
Cabling troughSupports in-cabinet cabling
PDMPower distribution
Fan moduleHeat dissipation unit
of the RF unit
Air ventilationHeat dissipation unit of
the RF unit
导风插箱射频单元散热处理
导风插箱射频单元散热处理
Baseband layerBaseband unit
configuration portB8200
BasebandUnit
Radio Unit Sector configurations:
WCDMA single mode: 30 CS
Baseband capacity: 960 CE
Transmit power: 60 W
Receive sensitivity
-129.2 dBm@dual antennas
Performance IndicesPerformance Indices
Iub interface
2 x STM-1; 16 x E1/T1; 2 x FE/GE
Interface IndicesInterface Indices
Indoor SDR Macro BTS in Dual Mode – ZXSDR BS8800
BasebandUnit
Radio Unit Dimensions950 mm x 600 mm x 450 mm
Weight (full configuration) 150kg
Typical power consumption 425 W in S1/1/1 configuration
Power supply -48 V DC
Physical IndicesPhysical Indices
60 W HPA providing sufficient power and performance
40% HPA reducing power
Indoor SDR Macro BTS in Dual Mode – ZXSDR BS8800
Outdoor SDR Macro BTS in Dual Mode – ZXSDR BS8900
Sector configurations:
WCDMA single mode: 30 CS
Baseband capacity: 960 CE
Transmit power:60 W
Receive sensitivity
-129.2 dBm@dual antennas
Dimensions
1900 x 950 x 600mm
Outdoor SDR Macro BTS in Dual Mode – ZXSDR BS8900
Weight (full configuration): 410 kg
Typical power consumption: 565
W in S1/1/1 configuration Power supply: -48 V DC, 220 V AC
Standby batteries: 2 groups of
150 AH batteries
BS8700
馈线馈线Jumper (coaxial
Remote optical cable
BS8700
2U
48.26 cm
BBUBBU: : B8200B8200 RRURRU
R8840R8840
4 carriers
Transmit power: 40 W/60 W
Size: 19 L
Weight: 16.5 Kg
BBU+RRU System Overview
B8200 Hardware System Structure
R8840/RSU40 Hardware System Structure
Introduction of SDR 8000 Series Products
Cable Connection and Networking
Content
Typical Networking Modes
Maximum levels of cascading: 4 Maximal transmission distance of each
level: 40 km Total maximum transmission distance: 10
0 km Maximum number of RRUs: 12
BBURRU RRU RRU RRU
Chain
RRU BBU RRU
RRU
Star
Node B Device Cable Connections