PXVISION BROWSER

The contained information in this handbook are only informative and they can being change without warning and they must not being understandings with some engagement from Promax srl. Promax srl does not assume responsibility or obligates for errors or

inaccuracies that can be found in this handbook. Except how much granted from the license, no part of this publication can be

reproduced, saved in a recording system or transmitted in whatever form or with any means, electronic, mechanical or recording system or otherwise without Promax srl authorization. Any reference to names of society or products have only demonstrative scope and it does not allude to some real organization.

Rev. 1.0.4 © Promax srl

Page 3: Á Á Á.proma Æ

3

PXVISION BROWSER

1 PREFACE This document describes the “PxVisionBrowser” application, that allows to configure PxVision system by Promax srl. PxVisionBrowser is only a configurator therefor it has not a real use in the applications. It allows to have a direct vision for parameters setting in the PxVision.

Page 4: Á Á Á.proma Æ

4

PXVISION BROWSER

2 Field Of View (FOV) Field Of View identifies angle of view horizontally and vertically seen from the camera.it depends of working distance and focal length of lens. Smaller fields, larger definitions.

2.1 PxVision/02-12 Manual Focus – focal length 12 mm. Minimum distance of focus 65 mm – FOV 27x20 mm

X Direction

Y Direction

Page 5: Á Á Á.proma Æ

5

PXVISION BROWSER

2.2 PxVision/02-16 Manual Focus – focal length 16 mm. Minimum distance of focus 16 mm Standard 95 mm – FOV 33.5x25.1 mm Minimum distance of focus 16 mm IR MEGA 55 mm – FOV 17.5x13.1 mm

X Direction

Y Direction

Page 6: Á Á Á.proma Æ

6

PXVISION BROWSER

2.3 PxVision/02-25 Manual Focus – focal length 25 mm. Minimum distance of focus 25 mm Standard 155 mm – FOV 29x21.7 mm

X Direction

Y Direction

Page 7: Á Á Á.proma Æ

7

PXVISION BROWSER

2.4 PxVision/01-0 Autofocus 85 Drg. Minimum distance of focus 90 mm – FOV 110x61.8 mm

X Direction

Y Direction

Page 8: Á Á Á.proma Æ

8

PXVISION BROWSER

2.5 PxVision/01-1 Autofocus 50 Drg. Minimum distance of focus 40 mm – FOV 42x33.6 mm

X Direction

Y Direction

Page 9: Á Á Á.proma Æ

9

PXVISION BROWSER

3 PxVisionBrowser Execution After installed the product (download setup from this Link) run PxVisionBrowser.exe that it is found in the PxVisonBrowser folder. Is recommended to install the product in the different folder of Windows Program Files.

3.1 Execution At start up PxVisionBrowser show a window that allows to use or create the new configurations.

PxVisionBrowser can use different configuration files. By this window can create new configuration files. The default configuration file is “PxVision.cfg”. The configuration files are in XML format and are found in the PxVisonBrowser folder.

3.2 Choice of Startup configuration In the combo box Current Configuration, are listed all configuration founded, so choose the desired configuration and press button “start”.

3.3 Create a new configuration In the TextBox New configuration, write the name of new configuration without extension and press button OK.

Will be create a new configuration file with the same parameters of default (PxVision.cfg). This new file will be added to configuration file list. Press button “start” for run the application with the new configuration file.

3.4 Delete a Configuration Press button “Del” for delete the configuration file selected. Isn’t possible delete the default configuration file PxVision.cfg.

3.5 Run by command line and arguments PxVisionBrowser like all Windows application, can be executed by command line with arguments. Can be used two arguments , where the first is the name of configuration file to use (with extension) and the second is the Server Ethernet state: PxVisionBrowser.exe PxVision.cfg 0 Run PxVisionBrowser with configuration PxVision.cfg and server ethernet disabled (See the chap. server ethernet)

Page 10: Á Á Á.proma Æ

10

PXVISION BROWSER

3.6 Check Updates From Button “Check Updates” is possible to check if are Updates for the PxVision system. For use this function, is necessary an Internet connection. Will be activated an external application that will check if updates are available.

If a new version is available, the Update is proposed. Before the updating, the system will generate a backup of current version. Press the button Update to proceed at the new package installation. During the installation, PxVisonBrowser will be closed and reopened when installation is finished. By button Restore is possible to restore a previous version.

Select the Backup to restore. The backup file is saved in the format: Year Month Day By button Del Zip is possible to delete a previous backup. The function is used like to Restore

3.7 Run without Camera PxVision By Button “No Cam” is possible to execute PxVisionBrowser without camera, using the images saved.

Use the button Load Image

Enable the function All functions are available excluded the camera controls.

Page 11: Á Á Á.proma Æ

11

PXVISION BROWSER

4 Unlock Windows Firewall If the Windows Firewall is enabled, at first execution of PxVisionBrowser, could be shown the following message:

See the following instructions for disable the Firewall on PxVisionBrowser: Enable the two checkbox

Press the button Allow access

Now PxVisionBrowser will be enabled to firewall The message will no longer be shown

For enable PxVisionBrowser without the above operations, see the following instructions: Open the Windows menu “Windows Security” - Firewall and Network protection

Click

Page 12: Á Á Á.proma Æ

12

PXVISION BROWSER

1) Click on “Allow an app through firewall”

2) Find the name “PxVisionBrowser”

Page 13: Á Á Á.proma Æ

13

PXVISION BROWSER

3) Press Button “Change settings”

4) Enable all check

5) Press Ok

Page 14: Á Á Á.proma Æ

14

PXVISION BROWSER

5 Home Screen

By home screen is possible use all PxVisionBrowser functions. The button Menu allows to open the functions list

Area camera image

Menù Bar

Camera Parameters, Filter etc.

Area functions data

Software Version and camera Firmware version

Page 15: Á Á Á.proma Æ

15

PXVISION BROWSER

6 Camera Calibration For a correct uses of PxVision is necessary a correct camera calibration, Focus,Brightness, Contrast etc. Normally is used the default parameters and isn’t necessary any correction. Only the correct focus is necessary. In the PxVision document is explained this procedure.

6.1 Camera Setting For check the camera parameters use the procedure: camera setting: Menù->Camera Setting

This function show the camera setting page. First to all is necessary to insert a sample image in the filed of view of the camera at the same distance of the objects that we want acquired. After that select the check Multi Frame and press button Start Test. The camera will capture the images and showed these in the window

Page 16: Á Á Á.proma Æ

16

PXVISION BROWSER

If the focus and the parameters are correct, the image will be show like above image.

6.2 General Parameters In the General Parameters section there are the parameters for setting special features of camera. Normally these parameters are not setted.

6.2.1 New Camera IP Address The PC IP address must be the same family of PxVision system, therefore if PxVision is IP: 10.0.0.82 the Pc must have for example IP STATIC 10.0.0.80. For setting a new IP address in PxVision, is necessary know the current IP Adrress, if it is unknow see the procedure for Reset parameters in the technical documentation PxVision Run PxVisionBrowser:

Press

Insert the new IP Address for PxVision and press SAVE.

The new IP Address will be activated at the new PxVisionBrowser StartUp

WARNING SELECT ALWAYS THE DLL PxPlusCamera.dll BEFORE SAVE

Page 17: Á Á Á.proma Æ

17

PXVISION BROWSER

6.2.2 Camera Rotation Angle Correction Is always advisable mounted the camera in a perfect angle with axes machine, however is possible correct the Angle by sliders: Rotation Angle Rotation X Center Rotation Y Center Rotation Angle Allows to rotate the image

Value 0 (ZERO), disabled Rotation X Center Allows to change the rotation Center X

Value -1 disabled Rotation Y Center Allows to change the rotation Center Y

Value -1 disabled Normally the Center X,Y are referred to Left up corner of camera For rotate the image to center camera insert:

Rotation X Center=Camera X Resolution/2 Rotation Y Center=Camera Y Resolution/2

Ex. For resolution 1600,1200 X Center=800 Y Center=600

6.2.3 Save Parameters By button SAVE the parameters are stored in the current configuration file.

6.2.4 Default Parameters By button Default are insert the default parameters

6.2.5 Camera Parameters Normally the default parameters are good but is possible change these by the following procedure Select “Par Camera” for main parameters

Isn’t explained the function for single parameter Use the sliders for adapting the image

Page 18: Á Á Á.proma Æ

18

PXVISION BROWSER

Select “Par Camera 2” for secondary parameters

ManualFocus Enabled only for AutoFocus Camera.

For use ManualFocus, disable the AutoFocus function and use the slider for adapting the focus

Auto Focus Enabled only for AutoFocus Camera If checked the AutoFocus function is enabled Power line Frequency Allows to select the Power Line Frequency for filtering the noise (OFF-50Hz-60Hz) AutoExposure Value Auto Exposure image (normally is used the default value) Gain Camera Gain (normally is used the default value) WhiteBalance White Balance (normally is used the default value) White Auto Balance If Checked the automatic white balance is activated (normally is used the default value)

6.2.6 Filterings Visualization The filters are essentials for images elaboration. Is by these that is possible to detected the objects. The filters are explained in the chapter.

Enable the check for see the image with filtering effects Is possible to change the filtering sequence, but normally isn’t necessary. By button Filter Def the default sequence is set. Select the Filter for changing by double click

Select the new filter position with double click (the filters will be change by position)

Page 19: Á Á Á.proma Æ

19

PXVISION BROWSER

6.2.7 Camera Colors Correction Normally almost all functions of PxVision aren’t need the colors images but is possible to correct the colors of camera. Select Color Correction

Enable Color Correction Enable the color correction function

Red channel correction Green channel correction Blue channel correction

Page 20: Á Á Á.proma Æ

20

PXVISION BROWSER

7 Image Source The image source can be the PxVison Camera or an image from file. Press button “Load Image” for load an image from file.

Activating the check “From File” the image will be get from file and not from camera. The check “Multi Frame” must be activated.

Page 21: Á Á Á.proma Æ

21

PXVISION BROWSER

8 Image Filtering Almost all PxVision function, works with image in black and white that are transformed from a color image by filtering process. In this chapter is explained the various effects all filters on an image.

The goal is to transform a COLOR image in a BLACK/WHITE image with defined contours.

Does not exist a specific rule of filtering, because the result depend from many factors (Quality of image, ambient light etc.). However the BINARY THRESHOLD gives almost always good results.

Button allows to reset the filter parameters by default

ORIGINAL IMAGE IN GRAY MODE FILTERING IMAGE BLACK/WHITE

The filters are in 3 tables

Page 22: Á Á Á.proma Æ

22

PXVISION BROWSER

8.1 Binary Threshold Is the main filter, it allows to set a Binary threshold on image, therefore the values above or below the threshold will be or BLACK or WHITE. This cause that the image will be contrasted and clear, and the functions can work optimally. Normally this filter isn’t combined with others filter but is in any case possible.

This filter can work on image Gray or color . However the best results are with Gray image

Treshold Threshold type

OFF None

0 Binary Threshold. The values of gray image less than Tl are converted in the Th value. The values greater or equal Tl are converted in BLACK value (0)

Image with Tl=116 Th=255

Page 23: Á Á Á.proma Æ

23

PXVISION BROWSER

1 Inverted Binary Threshold. Like Type 0 but are inverted BLACK and WHITE

Image with Tl=116 Th=255

2 Binary Threshold Fixed. The Tl value isn’t considered because is used a Fixed level value

Image with Th=255

3 Binary Threshold to Zero. The values less Tl are converted in BLACK (0) Th isn’t used

Image with Th=158

Page 24: Á Á Á.proma Æ

24

PXVISION BROWSER

4 Binary Threshold to Zero Inverted. The values less Tl are converted in WHITE (255) Th isn’t used

Image with Th=158

5 Binary Threshold Triangular. Is choosen a special algorithm for calculate the Tl parameter Image with Th=255

6 Binary Threshold Truncated. If the value is greater to Tl the value is converted in Tl. Th isn’t used

Image with Tl=96

Page 25: Á Á Á.proma Æ

25

PXVISION BROWSER

7-8 Gaussian Adaptive Threshold. All three parameters are activated Th,Tl,P1. A special algorithm search the contours of image

Image with Tl=254 – Th=18 – P1=9

9-10 Gaussian Adaptive Threshold. All three parameters are activated Th,Tl,P1. A special algorithm search the contours of image

Image with Tl=254 – Th=18 – P1=9

Page 26: Á Á Á.proma Æ

26

PXVISION BROWSER

8.2 Color Threshold RGB or HSV Is possible define the Binary threshold in the color models RGB or HSV. The image will be filter by the threshold color set. The results for RGB or HSV are the same, only the color model is different. Origina image

The Th HSV

By button acquire a “Rectangular area” that contains the color to filtering.

All parameters are set automatically.

The final result of filtering will be the following

Page 27: Á Á Á.proma Æ

27

PXVISION BROWSER

For set manually the values: move by mouse the bars Min Max

Page 28: Á Á Á.proma Æ

28

PXVISION BROWSER

8.3 Blur Filters Could be a paradox, but the images blur makes the contours more visible. The blur eliminate the noise of an image. The Blur filters are present in the table FILTER and they are GAUSSIAN, BLUR, MEDIAN, EROSION, DILATATION. The Blur Filters can combined

Image Without Blur Border aren’t defined cause noise

Image With Blur Border are good defined

Page 29: Á Á Á.proma Æ

29

PXVISION BROWSER

GAUSSIAN GAUSSIAN.

BLUR BLUR.

MEDIAN MEDIAN BLUR.

EROSION EROSION (Normally combined with DILITATION).

EROSION Type Erosion Type

EROSION Cp If Enabled will made EROSION/DILATATION of same value

DILATATION DILITATION (Normally combined with EROSION).

DILATATION Type Dilatation Type

DILATATION Cp If Enabled will made DILATATION/EROSION of same value

MORPHO MORPHOLOGY filter with parameters M. Size and M. Iterat.

Page 30: Á Á Á.proma Æ

30

PXVISION BROWSER

8.4 Filters for find contours These filters find the contours of image. LAPLACIAN and CANNY (C1 C2). They could be combined with others blur filters and Binary Threshold

LAPLACIAN LAPLACE algorithm

Threshold=OFF – GAUSSIAN=7 – LAPLACIAN=3

CANNY (C1 -C2) CANNY algorithm

Threshold=OFF – GAUSSIAN=5 – BLUR=6 – C1=120 – C2=81

Page 31: Á Á Á.proma Æ

31

PXVISION BROWSER

8.5 Brightness and Contrast filters These filters are similar to BRIGHTNESS and CONTRAST of the CAMERA Are in the table FILTER 2, GAMMA, ALPHA, BETA, Eq. Hist. Original Image Image with GAMMA=3.5 – ALPHA=1.8 – BETA=-4

Page 32: Á Á Á.proma Æ

32

PXVISION BROWSER

9 Region and Border image In some situation is better analyze an image portion instead of the whole image, that allow to exclude all pixels out side the Region. The region is defined by table REGION and works only if the function is enabled to use the Region (not all functions are enabled to use the region). The BORDER can define a rectangular Border with specific color and dimensions around the image, this allows to separate the image from the camera limits Up, Down, Left and Right.

9.1 Capture a Region For capture a REGION, is necessary to use a function enabled for the region use Ex: Marker Detection -> Marker Circular Start the images acquisition by START TEST for capture an image frame and press Stop Test (if Multi Frame is checked) Open REGION tab

The REGION is active if W (Width) parameter is different to -1 By TextBox X ,Y, W, H is possible to insert the values (Pixel). After insert the values press button SET REGION for REGION activation. For disable the region insert W=-1 (and press Set Region) or press button DISABLE REGION Is possible set a REGION by MOUSE. Press button By Mouse, and after click and hold with Left mouse button in an corner of desired region, drag the mouse pointer until desired region (a rectangular image will be showed) and release the left button. During the images acquisition, if a region is activated, a rectangular YELLOW border will be showed

X,Y

W (Width)

H (Height)

Page 33: Á Á Á.proma Æ

33

PXVISION BROWSER

9.2 Border Definition The BORDERS are defined as RECTANGULAR contour of image inside the REGION (if it is activated). Normally the BORDERS have to of Color how the background, that allows to separate the image with background. The use of Borders is useful when some particulars of image are outside the camera limits.

The BORDER definition separates the objects from camera limits

For define a BORDER set the parameters LEFT, RIGHT, TOP, BOTTOM they are the width in PIXEL of the BORDER in the four sides. The BORDER color is defined by parameters R,G,B (from 0 to 255) BLACK 0,0,0 – WHITE 255,255,255 Is important to set the color of border like background color, for see the background color use camera setting and capture an image without filters (real image), move the mouse pointer on the background an read the RGB values in the window:

The values read are the color of border The BORDER is disabled with LEFT = -1

In the image, the Black Lines are outside the left and right limits of camera. In this case some algorithms could not work good

Left Right

Top

Bottom

Page 34: Á Á Á.proma Æ

34

PXVISION BROWSER

10 Mask Definition The MASKS can be used for removing the background from an image. The MASK is defined as capture image of background without any object.

10.1 Mask Capture Start Camera Setting and Start Test with background image.

Open the TAB MaskImage, insert the Mask name in the field Mask File Name with extension .Jpg or without any extension.

Press button Acq Image and check the message box is ok

Now the background image is saved in the Test Mask Image. Enable the Check Enable Mask and Mask Mode AbsDiff , start new test

Page 35: Á Á Á.proma Æ

35

PXVISION BROWSER

If the Mask works good the image will be BLACK.

Inserting an object , this will be separate from the background.

Page 36: Á Á Á.proma Æ

36

PXVISION BROWSER

10.2 Region Definition for Mask Like CAMERA REGION is possible enable a MASK REGION. Press button SET for enable a MASK REGION

10.3 Mode Frame Mode Frame defines the mode of use the background image as MASK. Disable Disable.

The image capture with ACQ IMAGE is used as MASK

Continous At each frame capture by camera will be use sas MASK IMAGE Single The Background image will be captured only to first frame

(parameter FrameWork UseImageMaskLastFrame=2 for new acquisition)

10.4 Mask Mode Defines the algorithm used for separating the background from image. For a total elimination use AbsDiff.

10.4.1 AbsDiff Subtraction with absolute values from MASK and current FRAME.

Page 37: Á Á Á.proma Æ

37

PXVISION BROWSER

10.4.2 Add Sum with absolute values from MASK and current FRAME.

10.4.3 BitwiseAnd Bit AND from MASK and current FRAME.

10.4.4 BitwiseOr Bit OR from MASK and current FRAME.

10.4.5 BitwiseXor Bit XOR from MASK and current FRAME.

Page 38: Á Á Á.proma Æ

38

PXVISION BROWSER

10.4.6 BitwiseNot Bit NOT from MASK and current FRAME.

10.4.7 Max Max Values from MASK and current FRAME.

10.4.8 Min Min Values from MASK and current FRAME.

10.4.9 Subract Subract Values from MASK and current FRAME.

Page 39: Á Á Á.proma Æ

39

PXVISION BROWSER

10.4.10 CompareEqual Compare Equal from MASK and current FRAME.

10.4.11 CompareGreaterEqual,CompareGreaterThan,CompareLessEqual,CompareLessThan,CompareNotEqual

Compare from MASK and current FRAME.

Page 40: Á Á Á.proma Æ

40

PXVISION BROWSER

11 Illumination LED Not always the LED illumination help the images acquisition, in some situations, when the material is reflective, the LED can generate areas of reflected light that disturb the camera sensor.

11.1 S.O.

How can see in the two images, the image b) there are more areas of reflected light. This can cause erroneous acquisitions. The best solution is use a diffuse external light or natural illumination.

11.2 LED On From TAB LEDSTATUS is possible define how many and which LED must be lit during the Frame acquisition, is also possible to set the Power of Led.

Pressing the buttons from 1 to 8 the single LED is set On or Off (On button Red)

From Buttons ON - OFF the LED will be lit immediately for check the result Use slider POWER for power setting from 0 to 100%. The field Delay Led On is a time in Milliseconds, it defines the DELAY from LED ON and image acquisition, insert the value and press button SET. A value of -1 always keeps LED ON. The Delay Led On must be > of 500 Ms, this allow to adapting the camera at the Led Light. For testing the Delay Led

On use START TEST with check SINGLE FRAME activated

a) image with LED OFF b) image with LED ON

Reflecetd light

Example Lit LED 1,3,5,7

Page 41: Á Á Á.proma Æ

41

PXVISION BROWSER

12 Conversion Factor Pixel mm Normally the camera values are PIXEL, but is possible to set a conversion factor for transforming the PIXEL in mm. This allows to get the real measures of images.

12.1 Get the Conversion Factor For get the conversion factor use the following procedure. Insert an image with the known references with a distance enough high.

Activating the test from CAMERA SETTING, get an VALID IMAGE and stop the TEST Open the TAB CONVERSION FACTOR

Click on button By Mouse, move the mouse pointer in the FIRST reference and press and hold the left mouse button, drag the mouse (with left button pressed) in the SECOND reference and when the pointer is accurate on the SECOND reference, release the left mouse button (during the mouse drag will be show a line). If the references are at angle known like to 0,90 degree, during the drag use the shift key button for snap the line at angle.

Distance from center 60 mm

Page 42: Á Á Á.proma Æ

42

PXVISION BROWSER

After the following window will shown

In the text box insert the real measure in mm and press button Ok The conversion factor will be shown in the field:

Press SET activate it.

By buttons – and + is possible correct the conversion factor

Page 43: Á Á Á.proma Æ

43

PXVISION BROWSER

13 Utility From PxVisionBrowser is possible use the following system utility

Grid Capture Measure Zoom

13.1 Grid Draw a Grid over the images, it allows to get references for camera setting.

13.1.1 Center Circular Grid Normally used for verify Circular Marker Acquisition, the grid diameter is the same of Marker set. The grid is draw in the camera center.

By the slider is possible change the grid step:

13.1.2 Mobile Circular Grid Like Center Circular Grid, but the grid is draw in the center of marker capture

Page 44: Á Á Á.proma Æ

44

PXVISION BROWSER

13.1.3 Linear Grid Normal grid. The step is in PIXEL.

13.1.4 Square Grid Normally used for check Square Marker. The grid is draw from down right corner of marker captured. The STEP defines the grid angle

Page 45: Á Á Á.proma Æ

45

PXVISION BROWSER

13.2 Capture Allows to capture an image from camera and save it in JPG format.

13.2.1 Crop Image Allows to capture a RECTANGULAR image portion and save it in JPG format.

1) Move the mouse pointer in the first corner of image 2) Press and hold the left mouse button 3) Drag the mouse pointer (with left button pressed) in the second corner of image 4) Release the left button and save the image portion by name

13.2.2 Full Image Save the full image

13.3 Measure Allows to get measures from image captured

13.3.1 Line Line measures in Pixel, mm (the conversion factor must be correct) and angle in degrees.

1) Move the mouse pointer in the first point of image 2) Press and hold the left mouse button 3) Drag the mouse pointer (with left button pressed) in the second point of image

During all drag, a line will be drawn 4) Use the Shift key for snap line to angle

The results are showed in the field:

Length in Pixel (mm) Angle in degrees

13.3.2 Rectangle Rectangle measures in Pixel, mm (the conversion factor must be correct) Width and Height.

1) Move the mouse pointer in the first corner of image 2) Press and hold the left mouse button 3) Drag the mouse pointer (with left button pressed) in the second corner of image

During all drag, a rectangle will be drawn The results are showed in the field:

Width in Pixel (mm) Height in Pixel (mm)

Page 46: Á Á Á.proma Æ

46

PXVISION BROWSER

13.3.3 Circle Circular measures in Pixel, mm (the conversion factor must be correct) Radius and Diameter.

1) Move the mouse pointer in the center of circle to measure 2) Press and hold the left mouse button 3) Drag the mouse pointer (with left button pressed) to desired diameter

During all drag, a circle will be drawn The results are showed in the field:

Radius in Pixel (mm) Diameter in Pixel (mm)

13.4 Image Zoom Zoom image

13.4.1 From Mouse Wheel Move the mouse pointer in the center of image portion to zoom and rotate the mouse wheel for Zoom in or Zoom out

13.4.2 By Menù Open the menù Zoom and set the desired Zoom

13.5 Show Image Data Moving the mouse on image is possible to get the following image data:

X,Y Position in Pixel RGB Pixel Value

Gray Value if the image is captured in Gray

Page 47: Á Á Á.proma Æ

47

PXVISION BROWSER

14 Ethernet Server PxVisionBrowser allows to use a SERVER ETHERNET for connect external devices and use all PxVision functions. See the document for more informations

14.1 Server Parameters For activate the server must be set the parameters in the TAB ETH SERVER

IP ADDR Must be the same STATIC IP on the PC connect at PxVision SERVER MODE

Disable Server not enable Enable Browser Mode Server Enabled with PxVisionBrowser. The server monitor is in the TAB Enable Monitor Mode Server Enabled but PxVisionBrowser not activated. Only the monitor window is

visible Enable Mute Mode Server Enabled PxVisionBrowser and MONITOR not activated

The SERVER can be used by command line: 0 Disable 1 Enable Browser Mode 2 Enable Monitor Mode 3 Enable Mute Mode Ex: PxVisioneBrowser.exe PxVsion.cfg 2 Run PxVisioneBrowser with configuration file PxVision.cfg and server in Monitor Mode

Page 48: Á Á Á.proma Æ

48

PXVISION BROWSER

15 PxVision functions available Many functions are in PxVision system for system vision applications. PxVisionBrowser is used only for a correct setting of the functions and put in the configuration the parameters set. The functions available are divided by categories: MARKER DETECTION Marker recognition MEASURES Objects measures PROBE Point acquisition by probe DETECTOR Objects position and dimension detection FIND CONTOURS Find Contours and path conversion in Gcode or DXF BAR CODER READER Bar code and QrText reader OCR Reader Text reader

Page 49: Á Á Á.proma Æ

49

PXVISION BROWSER

16 Marker Detection It contains all functions for Marker Detection. PxVision use the predefined MARKER with known geometric shape. The MARKER normally is used for get a references like positions X,Y and Angle (ex: cut plotter machines) These are the precise detection, so the camera must be near to objects for use the max definition possible. Ex: Camera Resolution 1600,1200 Pixel FOV 50mm x 37.5mm Pixel Definition 0,031 mm x pixel The Markers detections are the following types:

Circular Marker Square Marker Type 1 Marker Hole Marker Find Match

Page 50: Á Á Á.proma Æ

50

PXVISION BROWSER

16.1 Circular Marker Detection of CENTER and ANGLE of CIRCULAR markers. The absolute value of Angle depends by marker used. The shape of Marker must have the following features: 0 DEGREES 45 DEGREES 89 DEGREES -45 DEGREES -89 DEGREES

0 DEGREES +44.9 DEGREES -44.9 DEGREES

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4,8 Fps

2048x1536 Pixel 6.9 Fps

1920x1080 Pixel 10 Fps

1600x1200 Pixel 7.2 Fps

1280x1024 Pixel 7,2 Fps

1280x720 Pixel 14.1 Fps

1024x768 Pixel 15.1 Fps

800x600 Pixel 16.3 Fps

1 Color BLACK on WHITE Angle detection from +89.9 to -89.9 Degrees Recommended size minimum Diameter 5 mm

2 Color BLACK on WHITE Angle detection from +44.9 to -44.9 Degrees Recommended size minimum Diameter 5 mm

Page 51: Á Á Á.proma Æ

51

PXVISION BROWSER

16.1.1 Parameters For a correct Marker detection is necessary to set the right Parameters

16.1.2 Marker Diameter Diameter Marker in Pixel, it is can get by mouse:

1) Capture an image with Marker, 2) Stop the continuous acquisition 3) Move the mouse pointer in the center of Marker 4) Press and hold the Left mouse button 5) Drag the mouse (with Left button pressed) on diameter desired 6) Release the Left Button mouse

16.1.3 Tolerance Percentage tolerance of diameter inserted. Set a low as possible

16.1.4 Accuracy This parameter normally is not changed. Defines the accuracy for Angle detection. Decrease the value if the angle isn’t detected right.

Page 52: Á Á Á.proma Æ

52

PXVISION BROWSER

16.1.5 Diameter % Parameter for angle detection, indicates the percentage of marker diameter where are detected the guidelines for angle calculation. The percentage is necessary for remaining outside or inside of MARKER:

16.1.6 Pixel Noise Parameter for Angle detection, it indicates the number of pixels as noise. If the image is well defined set the value to 1, otherwise set the value to number grater to pixel noise.

Image with Pixel noise

16.1.7 Pixel Pressure Parameter for Angle detection, it indicates the number of pixels of pressure on guidelines. Increase only if the angle isn’t detected regularly

In this MARKER type, the percentage must be lower to 100% for guidelines detection

Percentage 100% - not correct Percentage 90% Ok

Marker Border

In this MARKER type, the percentage can be lower or higher to 100% for guidelines detection

Percentage 110% - corretta

Percentage 90% Corretta

Page 53: Á Á Á.proma Æ

53

PXVISION BROWSER

16.1.8 Black Value Parameter for Angle detection, it indicates the limit value below which the pixel as BLACK and it is belonging to guidelines. To get the value, move the mouse on BLACK area of marker and reads the value in the field GRAY

16.1.9 White Value Parameter for Angle detection, it indicates the limit value above which the pixel as WHITE and it isn’t belonging to guidelines. To get the value, move the mouse on WHITE area of marker and reads the value in the field GRAY

Black Value

White Value

Page 54: Á Á Á.proma Æ

54

PXVISION BROWSER

16.1.10 Test Start test and check if the data acquired are corrected.

Marker Ok

All data are Pixel or mm if the button PIXEL is pressed W,H Width, Height Marker Cx,Cy Marker Center X,Y referred to up left corner of camera Dw,Dh Deviation error detected on W,H (if continuous frame) Dx,Dy Deviation error detected on Cx,Cy (if continuous frame) Angle Angle detected in degrees DAngle Deviation error detected on Angle (if continuous frame) Acq Acquisitions number Err Number of errors (Marker not detected) Sec Total time Fps Frames per second RESET Reset statistic data DEV Off/ON Show the center deviation on image Pixel/MM PIXEL/MM

Page 55: Á Á Á.proma Æ

55

PXVISION BROWSER

16.2 Square Marker Detection of CENTER and ANGLE of SQUARED markers. The absolute value of Angle depends by marker used RECTANGULAR or SQUARED. 0 DEGREES +44.9 DEGREES -44.9 DEGREES

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4,8 Fps

2048x1536 Pixel 6.9 Fps

1920x1080 Pixel 10 Fps

1600x1200 Pixel 7.2 Fps

1280x1024 Pixel 7,2 Fps

1280x720 Pixel 14.1 Fps

1024x768 Pixel 15.1 Fps

800x600 Pixel 16.3 Fps

Squared/Rectangular Color FULL BLACK (preferred) or BLACK only border Angle detection from +44.9 to -44.9 Degrees Recommended size minimum Size 5 mm

Page 56: Á Á Á.proma Æ

56

PXVISION BROWSER

16.2.1 Parameters For a correct Marker detection is necessary to set the right Parameters.

16.2.2 Width/Heigth Width and Height in Pixels of Marker it is can get by mouse:

1) Capture an image with Marker, 2) Stop the continuous acquisition 3) Move the mouse pointer in the first corner of marker 4) Press and hold the Left mouse button 5) Drag the mouse (with Left button pressed) on the second corner 6) Release the Left Button mouse

16.2.3 Tolerance Percentage tolerance of Width/Height inserted. Set a low as possible

16.2.4 Accuracy This parameter normally is not changed. Defines the accuracy for Angle detection. Decrease the value if the angle isn’t detected right.

Page 57: Á Á Á.proma Æ

57

PXVISION BROWSER

16.2.5 Test Start test and check if the data acquired are corrected.

Marker Ok

All data are Pixel or mm if the button PIXEL is pressed W,H Width, Height Marker Cx,Cy Marker Center X,Y referred to up left corner of camera Dw,Dh Deviation error detected on W,H (if continuous frame) Dx,Dy Deviation error detected on Cx,Cy (if continuous frame) Angle Angle detected in degrees DAngle Deviation error detected on Angle (if continuous frame) Acq Acquisitions number Err Number of errors (Marker not detected) Sec Total time Fps Frames per second RESET Reset statistic data DEV Off/ON Show the center deviation on image Pixel/MM PIXEL/MM Use Bounding Box If checked, for center detection, is used a special algorithm but in this case isn’t possible to

get the angle. This parameter is used only if the marker isn’t RECTANGULAR or SQUARED. Is necessary increase the TOLERANCE value up to the marker isn’t detection

Page 58: Á Á Á.proma Æ

58

PXVISION BROWSER

16.3 Type 1 Marker Detection of CENTER and ANGLE of CIRCULAR markers. The absolute value of Angle depends by marker used. The shape of Marker must have the following features: 0 DEGREES 90 DEGREES 180 DEGREES -90 DEGREES -10 DEGREES 0 DEGREES +89.9 DEGREES -89.9 DEGREES -45 DEGREES

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4,8 Fps

2048x1536 Pixel 6.9 Fps

1920x1080 Pixel 10 Fps

1600x1200 Pixel 7.2 Fps

1280x1024 Pixel 7,2 Fps

1280x720 Pixel 14.1 Fps

1024x768 Pixel 15.1 Fps

800x600 Pixel 16.3 Fps

1 Color BLACK on WHITE Angle detection from 0 to 360 Degrees Recommended size minimum Diameter 5 mm

2 Color BLACK on WHITE Angle detection from +179.9 to -179.9 Degrees Recommended size minimum Diameter 5 mm

Page 59: Á Á Á.proma Æ

59

PXVISION BROWSER

16.3.1 Parameters For a correct Marker detection is necessary to set the right Parameters.

16.3.2 Marker Diameter Diameter Marker in Pixel, it is can get by mouse: See Circular Marker

16.3.3 Tolerance See Circular Marker

16.3.4 Accuracy See Circular Marker

16.3.5 Diameter % See Circular Marker

16.3.6 Pixel Noise See Circular Marker

16.3.7 Pixel Pressure See Circular Marker

16.3.8 Black Value See Circular Marker

16.3.9 White Value See Circular Marker

Page 60: Á Á Á.proma Æ

60

PXVISION BROWSER

16.3.10 Test Start test and check if the data acquired are corrected.

Marker Ok

All data are Pixel or mm if the button PIXEL is pressed W,H Width, Height Marker Cx,Cy Marker Center X,Y referred to up left corner of camera Dw,Dh Deviation error detected on W,H (if continuous frame) Dx,Dy Deviation error detected on Cx,Cy (if continuous frame) Angle Angle detected in degrees DAngle Deviation error detected on Angle (if continuous frame) Acq Acquisitions number Err Number of errors (Marker not detected) Sec Total time Fps Frames per second RESET Reset statistic data DEV Off/ON Show the center deviation on image Pixel/MM PIXEL/MM

Page 61: Á Á Á.proma Æ

61

PXVISION BROWSER

16.4 Hole Marker Detection ONLY CENTER of circular marker. This function can detection all circular shape

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4,8 Fps

2048x1536 Pixel 6.9 Fps

1920x1080 Pixel 10 Fps

1600x1200 Pixel 7.2 Fps

1280x1024 Pixel 7,2 Fps

1280x720 Pixel 14.1 Fps

1024x768 Pixel 15.1 Fps

800x600 Pixel 16.3 Fps

Type Color FULL BLACK (preferred) or BLACK only border Angle not detected Recommended size minimum Diameter 5 mm

Page 62: Á Á Á.proma Æ

62

PXVISION BROWSER

16.4.1 Parameters For a correct Marker detection is necessary to set the right Parameters.

16.4.2 Hole Diameter Diameter Marker in Pixel, it is can get by mouse: See Circular Marker

16.4.3 Tolerance See Circular Marker

Page 63: Á Á Á.proma Æ

63

PXVISION BROWSER

16.4.4 Test Start test and check if the data acquired are corrected. The example test detects the HOLE on sheet metal.

HOLE Ok

All data are Pixel or mm if the button PIXEL is pressed W,H Width, Height Marker Cx,Cy Marker Center X,Y referred to up left corner of camera Dw,Dh Deviation error detected on W,H (if continuous frame) Dx,Dy Deviation error detected on Cx,Cy (if continuous frame) Angle Not Detected DAngle Not Detected Acq Acquisitions number Err Number of errors (Marker not detected) Sec Total time Fps Frames per second RESET Reset statistic data DEV Off/ON Show the center deviation on image Pixel/MM PIXEL/MM

Page 64: Á Á Á.proma Æ

64

PXVISION BROWSER

16.5 Find Match Detection of IMAGE PORTION on OBJECT. This function detects a portion of image previously saved in the file. The image to be detected can have the INCLINATION DIFFERENT to sample image. Is recommended the REGION use.

16.5.1 Capture a Sample image The sample image is acquired from PxVisionBrowser and saved in the file. The sample image must have the same colors and brightness of image in the object to detect, so this function not use any filtering process, but a real image. See the following steps for capture the sample image:

1) From CAMERA SETTING capture a camera FRAME of object that contains the image to find

2) By function CAPTURE→CROP cut the desired rectangular portion of image (ex: numbers from 1 to 0) And save it with name ex: TestFindMatch

16.5.2 Capture a Sample image By Mouse 3) From CAMERA SETTING capture a camera FRAME of object that contains the image to find 1) Press button “By Mouse” 2) Move the Selection Rectangle around the desired object

3) Press button SET

Page 65: Á Á Á.proma Æ

65

PXVISION BROWSER

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel

DATA NOT AVAILABLE

2048x1536 Pixel

1920x1080 Pixel

1600x1200 Pixel

1280x1024 Pixel

1280x720 Pixel

1024x768 Pixel

800x600 Pixel

Page 66: Á Á Á.proma Æ

66

PXVISION BROWSER

16.5.3 Parameters For a correct Marker detection is necessary to set the right Parameters.

16.5.4 Model Image By button LOAD open the sample image, By Mouse allows to select the image directly. Ex: “TestFindMatch.jpg”

16.5.5 Region Ok Is recommended use the REGION for this function, so define a CAMERA REGION from TAB REGION. If the region is defined, Region OK is the Width and Height for the MATCH acquired in proper way. Normally is set equal to camera region but can have different values for exclude false positive match. When the Match is detected, is tested the Bounding Box for the Match detected, if this is out of the tolerance defined in Region Ok, the match is discarded.

16.5.6 Score Ok The Match detected, is TRUE only if the score is valid. The score is shown in the data area during the marker detection, When the match is detected good set the Score Ok at value to Score shown

16.5.7 Type Search Selects the search mode, use the mode for max score.

Page 67: Á Á Á.proma Æ

67

PXVISION BROWSER

16.5.8 Multi Obj %

If the check is activated, defines the objects distance tolerance

16.5.9 Detect Angle If the value is > to 0, the angle of object will be detected. The system try to find the better correspondence from the values between: -DetectAngle and +DetectAngle, i.e. DetectAngle=30, the values to search are from -30 to+30 drg. When DetectAngle is used, set the Score lower values, this for ensure that the object will be found also at different angles. For a correct degrees values detected is necessary to store the object at 0 DRG. Insert a value max for an admissible object rotation. The max value is 35 Drg

16.5.10 Step Angle Step for search angle if DetecrtAngle>0, lower Step higher precision but more time needed.

16.5.11 Filter Angle LAPLACIAN filter for search angle. Normally use a value of 3.

Page 68: Á Á Á.proma Æ

68

PXVISION BROWSER

16.5.12 Test Start test and check if the data acquired are corrected.

Find Match Ok

All data are Pixel or mm if the button PIXEL is pressed W,H Width, Height Bounding Box Cx,Cy Centroid X,Y referred to up left corner of camera DCx,DCy Deviation error detected on Cx,Cy (if continuous frame) Angle Angle value detected in Drg Acq Acquisitions number Err Number of errors (Marker not detected) Sec Total time Fps Frames per second Score Score detected RESET Reset statistic data

Page 69: Á Á Á.proma Æ

69

PXVISION BROWSER

17 Measures It contains all functions for objects measure. About the camera mounting see MARKER DETECTION. The measures are the following types:

Cross Section Calliper Fit Line

Fit Circle Gap Cross Section

17.1 Common Parameters Some parameters are common for all measure functions, and they have the same usage.

17.1.1 DARK If ACTIVATED, the PROBE will moving in the direction set up to find a PIXEL VALUE <= GRAY VALUE. It is used when the PROBE start from WHITE POINT up to find BLACK POINT. If not ACTIVATED the PROBE will moving in the direction set up to find a PIXEL VALUE >= GRAY VALUE. It is used when the PROBE start from BLACK POINT up to find WHITE POINT. .

17.1.2 Inside It defines the PROBE DIRECTION (see above pictures)

Page 70: Á Á Á.proma Æ

70

PXVISION BROWSER

17.1.3 Pixel Noise Number of PIXEL as NOISE. The noise is defined some PIXELS of the same value of GRAY VALUE, but not belonging to Object to measure.

17.1.4 Pressure High/Low Number of PIXEL of PRESSURE must do the PROBE on the OBJECT when it has detected the right PIXEL. The pressure is necessary for detecting the object in a safety region.

17.1.5 Gray Value Value of PIXEL for REFERENCE. If DARK activated the PIXEL VALUE must be <= GRAY VALUE If DARK NOT activated the PIXEL VALUE must be >= GRAY VALUE

Pressure=1 Pressure=2

NOISE

Page 71: Á Á Á.proma Æ

71

PXVISION BROWSER

17.2 Cross Section Function that allows to measure Object Section. Is like to Calliper but has ONLY CONTACT POINT. The cross section can be measured CLOSING the TONGS (external measures) or OPENING the TONGS (internal measures). The measurement is made starting from a POSITION, and opening or closing, both Tongs until each Tongs will detect the right PIXEL (including Noise, Pressure). Ex: if the Tongs are starting from White Area, they will open or close until each will detect a black area. The distance from two points of contact is the measure detect. Can be insert up to 20 PROBES for a single section

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4,8 Fps

2048x1536 Pixel 6.9 Fps

1920x1080 Pixel 10 Fps

1600x1200 Pixel 7.2 Fps

1280x1024 Pixel 7,2 Fps

1280x720 Pixel 11.2 Fps

1024x768 Pixel 13.1 Fps

800x600 Pixel 15.4 Fps

EXTERNAL Closing Tongs Pinze

INTERNAL Opening Tongs

Page 72: Á Á Á.proma Æ

72

PXVISION BROWSER

17.2.1 Parameters The parameters can set for a maximum of 20 probes

17.2.2 Probe Add/Remove Press button ADD for add a new probe. Press button REMOVE, for remove the selected probe

17.2.3 Select a Probe By Combo Box “Cross Section Selected” is selected a PROBE for show the parameters.

17.2.4 Probe Position In the fields Position, are represented the position parameters of PROBE selected. The position parameters are in PIXEL and referred to Camera view. The probe is composed of two Tongs.

StartX,StartY

EndX,EndY

1

1

Page 73: Á Á Á.proma Æ

73

PXVISION BROWSER

INSIDE PROBE (Inside checked), it closes the Tongs until the max excursion defined by both tongs both in contact EXTERNAL PROBE (Inside unchecked), it opens the Tongs until the max excursion defined by one or both the tongs are outside the camera limits. By button SET are validated the positions insert manually. By button MOVE is possible positioner the PROBE by mouse, will activate the handles by through which is possible manipulate the PROBE (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a PROBE from START point to END point like a LINE. From field Angle is possible set the Probe angle manually (press button SET for validated the value).

Page 74: Á Á Á.proma Æ

74

PXVISION BROWSER

17.2.5 Test Start the test for check the acquired values

Correct Values acquired for 3 PROBE (2 Inside and 1 Outside)

Data show for selected Probe Measure Pixel Measure detected in PIXEL (Distance from two tongs) Measure mm Measure detected in mm (Distance from two tongs) Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Page 75: Á Á Á.proma Æ

75

PXVISION BROWSER

17.3 Gap Cross Section Function that allows to measure a Gap (min value and Max value) from Object Section. The cross section can be measured CLOSING the TONGS (external measures) or OPENING the TONGS (internal measures). The measure will be getting from START POINT, for a total programmed LENGTH, the min value and max value will saved. Can be insert up to 20 PROBES for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.7 Fps

2048x1536 Pixel 5 Fps

1920x1080 Pixel 9.4 Fps

1600x1200 Pixel 7 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.3 Fps

1024x768 Pixel 13 Fps

800x600 Pixel 15 Fps

Start Point

INTERNAL Opening Tongs

End Point

EXTERNAL Closing Tongs

Page 76: Á Á Á.proma Æ

76

PXVISION BROWSER

17.3.1 Parameters The parameters can set for a maximum of 20 probes

17.3.2 Probe Add/Remove Press button ADD for add a new probe. Press button REMOVE, for remove the selected probe

17.3.3 Select a Probe By Combo Box “Cross Section Selected” is selected a PROBE for show the parameters.

17.3.4 Probe Position In the fields Position, are represented the position parameters of PROBE selected. The position parameters are in PIXEL and referred to Camera view. The probe is composed of two cursors. The inside parameter determinate if the cursor will be opening or closing. StartX,StartY and EndX,EndY is the field of MISURATION for detect MINUM and MAXIMUM GAP

StartX,StartY

EndX,EndY

Opening

Page 77: Á Á Á.proma Æ

77

PXVISION BROWSER

The INSIDE PROBE (Inside checked), closes the cursors for all length and get the min/max value detected. The OUTSIDE PROBE (Inside unchecked), Opens the cursors for all length and get the min/max value detected. By button SET are validated the positions insert manually. By button MOVE is possible positioner the PROBE by mouse, will activate the handles by through which is possible manipulate the PROBE (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a PROBE from START point to END point like a LINE. From field Angle is possible set the Probe angle manually (press button SET for validated the value).

17.3.5 Min Gap Minimum value in PIXEL detectable, smaller values aren’t read

Page 78: Á Á Á.proma Æ

78

PXVISION BROWSER

17.3.6 Test Start the test for check the acquired values

Correct Values acquired for 1 PROBE (1 Inside and 1 Outside)

Data show for selected Probe Measure Pixel Measure detected in PIXEL (Dmin Min Delta error – Dmax Max Delta error) Measure mm Measure detected in mm (Dmin Min Delta error – Dmax Max Delta error) Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Inside

Outside

Page 79: Á Á Á.proma Æ

79

PXVISION BROWSER

17.4 Cross Lines This function allows to detect the ORIGIN and INCLINATION of a RECTANGULAR OBJECT For a correct detection, the OBJECT must be positioned in the following mode in the AREA SEARCH: Serach Area 0 Dgr Serach Area 90 Dgr

Edge of Object in Upper Right Corner of search area. Max Inclination +/- 45 dgr

Edge of Object in Bottom Right Corner of search area. Max Inclination +/- 45 dgr

Page 80: Á Á Á.proma Æ

80

PXVISION BROWSER

Serach Area 180 Dgr Serach Area 270 Dgr

Edge of Object in Bottom Left Corner of search area. Max Inclination +/- 45 dgr

Edge of Object in Upper Left Corner of search area. Max Inclination +/- 45 dgr

Page 81: Á Á Á.proma Æ

81

PXVISION BROWSER

The result will be the ORIGIN POINT Ox,Oy of the EDGE and INCLINATION Alpha 1,Alpha 2 of the OBJECT Can be insert up to 5 SEARCH AREAS

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel Fit Mode 1.3 Fps – Lines Mode 4.8 Fps – Probe Mode 1.6 Fps

2048x1536 Pixel Fit Mode 1.8 Fps – Lines Mode 5.4 Fps – Probe Mode 2.8 Fps

1920x1080 Pixel Fit Mode 3.1 Fps – Lines Mode 9.6 Fps – Probe Mode 4.2 Fps

1600x1200 Pixel Fit Mode 2.4 Fps – Lines Mode 7.1 Fps – Probe Mode 4.3 Fps

1280x1024 Pixel Fit Mode 3.1 Fps – Lines Mode 7.2 Fps – Probe Mode 4.7 Fps

1280x720 Pixel Fit Mode 5.6 Fps – Lines Mode 11.1 Fps – Probe Mode 7.9 Fps

1024x768 Pixel Fit Mode 6.3 Fps – Lines Mode 12.5 Fps – Probe Mode 10.4 Fps

800x600 Pixel Fit Mode 7.6 Fps – Lines Mode 14.1 Fps – Probe Mode 11.7 Fps

Ox,Oy

Page 82: Á Á Á.proma Æ

82

PXVISION BROWSER

17.4.1 Parameters The parameters can set for a maximum of 5 Cross Lines

17.4.2 Cross Lines Add/Remove Press button ADD for add a Cross Lines. Press button REMOVE, for remove the selected Cross Lines 17.4.3 Cross Lines Selection By Combo Box “CrossLines Index Selected” is selected a CROSSLINES for show the parameters.

17.4.4 Cross Lines Position

In the fields Position, are represented the position parameters of CROSSLINES selected. The position parameters are in PIXEL. The CROSSLINES is an RECTANGULAR AREA that can be positioned in FOUR ANGLES 0-90-180-270 Dgr. By Button SET all position parameters are inserted MANUALLY. By button MOVE is possible positioner the CROSS LINES by mouse, will activate the handles by through which is possible manipulate the CROSS LINES Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a PROBE from START point to END point like a LINE.

Click 0

Gradi

Click 90

Gradi

Click 180

Gradi

Click 270

Gradi

Page 83: Á Á Á.proma Æ

83

PXVISION BROWSER

17.4.5 Drg Select in the Combo Box Drg the angle of SEARCH AREA. 17.4.6 Dark Search on BLACK or WHITE OBJECTS. 17.4.7 Min Area Clean When is activated, the outside and inside region of Search Area will be cleaned of noise.

Page 84: Á Á Á.proma Æ

84

PXVISION BROWSER

17.4.8 Mode There are 3 different mode of search used according to the background and object contrast. 17.4.9 Mode Fit Line Uses a Fit Line combination for detect the TWO SIDES of object, after will be detect the ORIGIN POINT and Angle. This mode is suitable for objects without a perfect separation with background. The object must be well defined.

Enable 1 - Enable 2 Enable or Disable one of two Sides. Only if the Two sides are enabled the Origin Point will be detected Grip Step Grip open FIT LINE. Small values for Objects with Higher contour noise. Great values for Objects Lower contour noise. Step Definition Step. Lower values great definition. Example of Use Image with background noise

Page 85: Á Á Á.proma Æ

85

PXVISION BROWSER

17.4.10 Mode Lines Detects the contour lines of the object. This function is suitable also for objects with not separate background.

Near Cross Tolerance on the intersection points. Set the value by the best result. Angle % Angles tolerance. Small values, great precision. Duplicate % Duplicate lines tolerance. Line Def. Lines search definition. Example of Use Image with background noise and not defined,

Page 86: Á Á Á.proma Æ

86

PXVISION BROWSER

17.4.11 Mode Probe Uses a PROBE for detect the Object side. Suitable for FILLED OBJECT with great background noise. Force the Min Area Clean

Noise Pixel Noise Step PROBE Step. Small Values, Great precision. Angle % Angles tolerance. Small Values, Great precision. Example of Use Image with background noise.

ù

Page 87: Á Á Á.proma Æ

87

PXVISION BROWSER

17.4.12 Test Start the test for check the acquired values

Correct Values acquired for 1 CrossLines

Data show for selected Cross Lines Angle 1 Angle in Drg for LINE GREEN (Da Delta Error) Angle 2 Angle in Drg for LINE BLUE (Da Delta Error) Cross Point (Px) Origin Point in Pixel (Dx,Dy Delta Error) Cross Point (mm) Origin Point in mm (Dx,Dy Delta Erroe) Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET DATA Reset statistic data

Page 88: Á Á Á.proma Æ

88

PXVISION BROWSER

17.5 Calliper Objects measures like to CALIPER. The measure is made starting from the POSITION of TWO TONGS and opening or closing the tongs until BOTH detected a contact point with value GRAY set in the PARAMETERS. Ex: if the tongs are starting from the WHITE AREA (like to above example), the both tongs will opening or closing until to detect a BLACK AREA, the distance from the two contact points is the measure detected. Can be insert up to 10 CALLIPERS for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.7 Fps

2048x1536 Pixel 4.9 Fps

1920x1080 Pixel 9.3 Fps

1600x1200 Pixel 7.1 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.3 Fps

1024x768 Pixel 12 Fps

800x600 Pixel 14.8 Fps

Start Point

INTERNAL Opens Tongs

End Point

EXTERNAL Close Tongs

Base Width

Page 89: Á Á Á.proma Æ

89

PXVISION BROWSER

17.5.1 Parameters The parameters can set for a maximum of 10 Callipers

17.5.2 Calliper Add/Remove Press button ADD for add a new Calliper. Press button REMOVE, for remove the selected Calliper

17.5.3 Select a Calliper By Combo Box “Calliper Index Selected”” is selected a CALLIPER for show the parameters.

17.5.4 Calliper Position In the fields Position, are represented the position parameters of CALLIPER selected. The position parameters are in PIXEL and referred to Camera view. The calliper is composed of two cursors. The inside parameter determinate if the cursor will be opening or closing. StartX,StartY and EndX,EndY is the field of MISURATION for detect the measure

EndX,EndY

StartX,StartY

Page 90: Á Á Á.proma Æ

90

PXVISION BROWSER

The INTERNAL CALLIPER (Inside checked) closes the tongs and detect the first contact point for each tong The EXTERNAL CALLIPER (Inside unchecked) opens the tongs and detect the first contact point for each tong By button SET are validated the positions insert manually. By button MOVE is possible positioner the CALLIPER by mouse, will activate the handles by through which is possible manipulate the CALLIPER (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a CALLIPER from START point to END point like a LINE. From field Angle is possible set the Calliper angle manually (press button SET for validated the value).

Page 91: Á Á Á.proma Æ

91

PXVISION BROWSER

17.5.5 Test Start the test for check the acquired values

Correct Values acquired for 2 CALLIPERS (1 Inside and 1 Outside)

Data show for selected Calliper Measure Pixel Measure detected in PIXEL (D Min Delta error) Measure mm Measure detected in mm (D Min Delta error) Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Internal External

Page 92: Á Á Á.proma Æ

92

PXVISION BROWSER

17.6 Fit Line Function that allows to find a BEST LINE from a Object profile. Is possible to use up to four algorithms for find a line: Least Square Find a BEST LINE from a points cloud First End LINE from FIRST and LAST point detected First Middle LINE from FIRST and MIDDLE point detected Middle End LINE from MIDDLE and LAST point detected Results from four algorithms on IRREGULAR path, YELLOW LINE is the best line found

The measure is made starting from StartX,StartY up to EndX,EndY Can be insert up to 10 FIT LINE for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.7 Fps

2048x1536 Pixel 4.9 Fps

1920x1080 Pixel 9.2 Fps

1600x1200 Pixel 7 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.6 Fps

1024x768 Pixel 12.4 Fps

800x600 Pixel 15 Fps

Least Square

First End

First Middle

Middle End

Page 93: Á Á Á.proma Æ

93

PXVISION BROWSER

17.6.1 Parameters The parameters can set for a maximum of 10 Fit Line

17.6.2 Fit Line Add/Remove Press button ADD for add a new Fit Line. Press button REMOVE, for remove the selected Fit Line

17.6.3 Select a Fit Line By Combo Box “FitLine Index Selected is selected a Fit Line for show the parameters.

17.6.4 Fit Line Position In the fields Position, are represented the position parameters of Fit Line selected. The position parameters are in PIXEL and referred to Camera view. The Fit Line is composed of one rectangle where Width and Height defines the field of measurement.

StartX,StartY 1

1 EndX,EndY

Page 94: Á Á Á.proma Æ

94

PXVISION BROWSER

The points for LINE detect are found from Start X,Y and End X,Y, this length is interpolated by STEP for all WIDTH. Is important that the rectangle not exceeds the profile to measure. By button SET are validated the positions insert manually. By button MOVE is possible positioner the FIT LINE by mouse, will activate the handles by through which is possible manipulate the Fit Line (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a Fit Line from START point to END point like a LINE. From field Angle is possible set the Fit Line angle manually (press button SET for validated the value).

17.6.5 Select a Find Mode Open the Combo Box and select the desired mode for a best result

17.6.6 Step Interpolation STEP for find points of the LINE Lower values higher points definition

NOT CORRECT

CORRECT

Page 95: Á Á Á.proma Æ

95

PXVISION BROWSER

17.6.7 Test Start the test for check the acquired values

Values acquired for 2 FIT LINES

Data show for selected Fit Line Fit Line Angle Fit Line Angle Detected Probe Acq Measure in Pixel and mm of line Detected Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Page 96: Á Á Á.proma Æ

96

PXVISION BROWSER

17.7 Fit Circle Function that allows to find a BEST CIRCLE from a Object profile. Is possible to use up to two algorithms for find a circle: Least Square Find a BEST CIRCLE from a points cloud 3 Points Circle from 3 POINTS (First, Middle and Last) Results from 2 Algorithms on IRREGULAR PROFILE, the YELLOW CIRCLE is the circle found

The measure is made starting from a Start Angle up to End Angle Can be insert up to 10 FIT CIRCLE for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.7 Fps

2048x1536 Pixel 5 Fps

1920x1080 Pixel 9.5 Fps

1600x1200 Pixel 7 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.2 Fps

1024x768 Pixel 12.3 Fps

800x600 Pixel 15.4 Fps

Least Square

3 Points

Page 97: Á Á Á.proma Æ

97

PXVISION BROWSER

17.7.1 Parameters The parameters can set for a maximum of 10 Fit Line

17.7.2 Fit Circle Add/Remove Press button ADD for add a new Fit Circle. Press button REMOVE, for remove the selected Fit Circle

17.7.3 Select a Fit Circle By Combo Box “FitCircle Index Selected is selected a Fit Circle for show the parameters.

17.7.4 Fit Circle Position In the fields Position, are represented the position parameters of Fit Circle selected. The position parameters are in PIXEL and referred to Camera view. The Start Angle and End Angle define the field of measurement. The measurement is made from External Radius to Internal Radius or Vice versa. External Radius

Internal Radius

Start Angle End Angle

Step

Page 98: Á Á Á.proma Æ

98

PXVISION BROWSER

The points for CIRCLE detect are found from Start Angle and End Angle, this length is interpolated by STEP Is important that the arc not exceeds the profile to measure. By button SET are validated the positions insert manually. By button MOVE is possible positioner the FIT CIRCLE by mouse, will activate the handles by through which is possible manipulate the Fit Circle (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a Fit Circle from START point to END point like a CIRCLE. From fields S Angle and E Angle is possible to set the Fit Circle Start/End Angle manually (press button SET for validated the value ). From fields R Ext and R int is possible to set the Fit Circle External/Internal Radius manually (press button SET for validated the value ).

NOT CORRECT

CORRECT

Page 99: Á Á Á.proma Æ

99

PXVISION BROWSER

17.7.5 Select a Find Mode Open the Combo Box and select the desired mode for a best result

17.7.6 Step Interpolation STEP for find points of the CIRCLE Lower values higher points definition

Page 100: Á Á Á.proma Æ

100

PXVISION BROWSER

17.7.7 Test Start the test for check the acquired values

Values acquired for 2 FIT CIRCLES

Data show for selected Fit Circle Circle Center Circle Center (pixel e mm) Dx,Dy Delta Error Cx,Cy Circle Radius Circle Radius (pixel e mm) Dr Delta Error Radius Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Page 101: Á Á Á.proma Æ

101

PXVISION BROWSER

18 Probe It contains all functions for objects Position. About the camera mounting see MARKER DETECTION. The probes are like to sensor that allow to acquire Objects Position The measures are the following types:

Probe Single Point Probe Line

18.1 Common Parameters Some parameters are common for all measure functions, and they have the same usage.

18.1.1 DARK If ACTIVATED, the PROBE will moving in the direction set up to find a PIXEL VALUE <= GRAY VALUE. It is used when the PROBE start from WHITE POINT up to find BLACK POINT. If not ACTIVATED the PROBE will moving in the direction set up to find a PIXEL VALUE >= GRAY VALUE. It is used when the PROBE start from BLACK POINT up to find WHITE POINT .

18.1.2 Pixel Noise See Pixel Noise

18.1.3 Pressure See Pressure

18.1.4 Gray Value See Gray Value.

Pressure=1 Pressure=2

Page 102: Á Á Á.proma Æ

102

PXVISION BROWSER

18.2 Probe Single Point Probe for contact on SINGLE POINT The probe start from Start X,Y to End X,Y. Can be insert up to 20 PROBE for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.6 Fps

2048x1536 Pixel 5 Fps

1920x1080 Pixel 9.4 Fps

1600x1200 Pixel 7.1 Fps

1280x1024 Pixel 7.1 Fps

1280x720 Pixel 11.8 Fps

1024x768 Pixel 13.2 Fps

800x600 Pixel 15.3 Fps

Page 103: Á Á Á.proma Æ

103

PXVISION BROWSER

18.2.1 Parameters The parameters can set for a maximum of 20 Probes

18.2.2 Probe Add/Remove Press button ADD for add a new Probe. Press button REMOVE, for remove the selected Probe

18.2.3 Select a Probe By Combo Box “Probe Index Selected is selected a Probe for show the parameters.

18.2.4 Probe Position In the fields Position, are represented the position parameters of Probe selected. The position parameters are in PIXEL and referred to Camera view. The Probe start from StartX,StartY to EndX,EndY.

StartX,StartY

EndX,EndY

Page 104: Á Á Á.proma Æ

104

PXVISION BROWSER

By button BY MOUSE is possible to draw a Probe from START point to END point like a LINE. From fields StartX,StartY,EndX,Endy is possible to set parameters manually (press button SET for validated the value ). By button MOVE is possible positioner the PROBE by mouse, will activate the handles by through which is possible manipulate the Fit Circle (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a Probe from START point to END point like a LINE. From field Angle is possible to set the Probe Angle manually (press button SET for validated the value ).

Page 105: Á Á Á.proma Æ

105

PXVISION BROWSER

18.2.5 Test Start the test for check the acquired values

Values acquired for 3 Probes

Data show for selected Probe Probe Acq Pixel X,Y Point in Pixel (Dx,Dy Delta Error) Probe Acq mm X,Y Point in mm (Dx,Dy Delta Error) Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Page 106: Á Á Á.proma Æ

106

PXVISION BROWSER

18.3 Probe Line Probe with contact on a LINE The probe start from Start X,Y to End X,Y and will finish on first contact point detected. Can be insert up to 20 PROBE for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.7 Fps

2048x1536 Pixel 4.9 Fps

1920x1080 Pixel 9.3 Fps

1600x1200 Pixel 7 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.1 Fps

1024x768 Pixel 12.5 Fps

800x600 Pixel 14.9 Fps

Page 107: Á Á Á.proma Æ

107

PXVISION BROWSER

18.3.1 Parameters The parameters can set for a maximum of 20 Probes

18.3.2 Probe Add/Remove Press button ADD for add a new Probe. Press button REMOVE, for remove the selected Probe

18.3.3 Select a Probe By Combo Box “Probe Index Selected is selected a Probe for show the parameters.

18.3.4 Probe Position In the fields Position, are represented the position parameters of Probe selected. The position parameters are in PIXEL and referred to Camera view. The Probe start from StartX,StartY to EndX,EndY.

StartX,StartY

EndX,EndY

Page 108: Á Á Á.proma Æ

108

PXVISION BROWSER

By button BY MOUSE is possible to draw a Probe from START point to END point like a LINE. From fields StartX,StartY,EndX,Endy is possible to set parameters manually (press button SET for validated the value ). By button MOVE is possible positioner the PROBE by mouse, will activate the handles by through which is possible manipulate the Fit Circle (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a Probe from START point to END point like a LINE. From field Angle is possible to set the Probe Angle manually (press button SET for validated the value ).

Page 109: Á Á Á.proma Æ

109

PXVISION BROWSER

18.3.5 Test Start the test for check the acquired values

Values acquired for 2 Probes

Data show for selected Probe Probe Acq Pixel X,Y Point in Pixel (Dx,Dy Delta Error) Probe Acq mm X,Y Point in mm (Dx,Dy Delta Error) Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Page 110: Á Á Á.proma Æ

110

PXVISION BROWSER

18.4 Probe Angle Probe for Angle detection

The probe start from Start X,Y to End X,Y and will finish on two contact points From two contacts points will be detected the Line Angle Can be insert up to 20 PROBE for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 6.9 Fps

2048x1536 Pixel 7.1 Fps

1920x1080 Pixel 11.5 Fps

1600x1200 Pixel 7.1 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 14.3 Fps

1024x768 Pixel 15.3 Fps

800x600 Pixel 16 Fps

Contact Points

Angle Detected

Page 111: Á Á Á.proma Æ

111

PXVISION BROWSER

18.4.1 Parameters The parameters can set for a maximum of 20 Probes

18.4.2 Probe Add/Remove Press button ADD for add a new Probe. Press button REMOVE, for remove the selected Probe

18.4.3 Select a Probe By Combo Box “Probe Index Selected is selected a Probe for show the parameters.

18.4.4 Probe Position In the fields Position, are represented the position parameters of Probe selected. The position parameters are in PIXEL and referred to Camera view. The Probe start from StartX,StartY to EndX,EndY.

StartX,StartY

EndX,EndY

Page 112: Á Á Á.proma Æ

112

PXVISION BROWSER

By button BY MOUSE is possible to draw a Probe from START point to END point like a LINE. From fields StartX,StartY,EndX,Endy is possible to set parameters manually (press button SET for validated the value ). By button MOVE is possible positioner the PROBE by mouse, will activate the handles by through which is possible manipulate the Fit Circle (dimensions, position. Angle etc.) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically. By button BY MOUSE is possible to draw a Probe from START point to END point like a LINE. From field Angle is possible to set the Probe Angle manually (press button SET for validated the value ).

Page 113: Á Á Á.proma Æ

113

PXVISION BROWSER

18.4.5 Test Start the test for check the acquired values

Values acquired for 2 Probes

Data show for selected Probe Angle Angle Detected (Da Delta Error) Probe Acq Pixel X,Y – X1,Y1 Contact Points in Pixel Probe Acq mm X,Y – X1,Y1 Contact Points in mm Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

Page 114: Á Á Á.proma Æ

114

PXVISION BROWSER

19 Detector Contains all functions for OBJECTS detection. The detectors are the following types:

Gray Detector Contrast Detector

Brightness Detector Objects Color Detector Objects Area Detector

19.1 Common Parameters Some parameters are common for all detector functions, and they have the same usage.

19.1.1 Region for Gray – Contrast - Brightness Region MANDATORY area where is check the OBJECT. The Region can be RECTANGULAR or CIRCULAR and is get by combo box Region

The button RECT defines a RECTANGULAR region, the button CIRCLE defines a CIRCULAR region

The data can be modified MANUALLY and activated by button SET.

19.1.2 Region for Objects Color – Objects Area Region NOT MANDATORY area where is check the OBJECTS. The region can be ONLY RECTANGULAR.

Page 115: Á Á Á.proma Æ

115

PXVISION BROWSER

19.1.3 Invalid Region for Gray – Contrast - Brightness Is possible invalidate a portion of region, this area will not checked for object detection. INVALID REGION is a POINTS X,Y sequence (Poly Line) and can be set only by MOUSE. Can be set up to 5 INVALID REGION.

In Select a INVALID REGION Add Add a new INVALID REGION Remove Remove INVALID REGION selected By Mouse Draw by mouse a INVALID REGION

Move the mouse cursor on the first point of invalidated region and click with left mouse button for draw a closed poly line

19.1.4 RGB Channel for Gray – Contrast - Brightness Indicates which CHANNEL of color is used for getting the comparison data Normally is used the GRAY channel

19.1.5 Detector Add/Remove Press button ADD for add a new detector. Press button REMOVE, for remove the selected detector

19.1.6 Select a Detector By Combo Box “Detector Index Selected” is selected a DETECTOR for show the parameters.

Start Point

Points Sequence

Close

Page 116: Á Á Á.proma Æ

116

PXVISION BROWSER

19.1.7 Detector position for Gray – Contrast - Brightness In the fields Region, are present all parameters for the REGION position to analyse. The Region can be RECTANGULAR or CIRCULAR. By button SET is validated the data insert. By button MOVE is possible to move the REGION by mouse, will activate the handles by through which is possible manipulate the REGION (dimensions, position) Press the left mouse button on the handle and drag it in the desired position. The values will update automatically.

19.1.8 Type Area for Objects Color – Objects Area Defines the type of AREA for object detection, so the object shape. The data acquired must satisfy the parameters for the type of area selected.

Free Area Free shape object: Min Area Minimum area detectable in PIXEL. Values less are excluded Max Area Maximum area detectable in PIXEL. Values greater are excluded Rectangle Area Rectangle shape object: Width Width in PIXEL. Height Height in PIXEL. Tolerance Tolerance on Width, Height. Values outside are excluded By button RECT is possible to acquire the region by MOUSE. Circle Area Circular shape object: Diameter Diameter in PIXEL. Tolerance Tolerance on Diameter. Values outside are excluded By button CIRCLE is possible to acquire the region by MOUSE.

Page 117: Á Á Á.proma Æ

117

PXVISION BROWSER

19.2 Gray Detector Search in a REGION a quantity of PIXEL that satisfy the parameters set. Normally used for detecting a presence of OBJECTS. The algorithm is based on compare the PIXELS in GRAY VALUE from 0 to 255, the final result is validated by a percentage of valid pixels. This function doesn’t detect the object position, but only the object presence. Can be insert up to 20 GRAY DETECTOR for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.6 Fps

2048x1536 Pixel 5 Fps

1920x1080 Pixel 9.4 Fps

1600x1200 Pixel 7 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.5 Fps

1024x768 Pixel 13 Fps

800x600 Pixel 15.1 Fps

Page 118: Á Á Á.proma Æ

118

PXVISION BROWSER

19.2.1 Parameters The parameters can set for a maximum of 20 Gray Detector

19.2.2 Gray Min MINIMUM value of PIXEL for the CHANNEL Setted Values less this are excluded.

19.2.3 Gray Max – Gray Detector MAXIMUM value of PIXEL for the CHANNEL Setted Values greater this are excluded.

19.2.4 ThMin - ThMax PERCENTAGE interval for final data VALID. The calculation is made on all PIXELS of REGION, the INVALID REGION PIXELS will be excluded, the PIXELS of the area that are in the interval of GRAY MIN and GRAY MAX, are pixels valid. The percentage of VALID PIXELS must be inside the interval of TH MIN and TH MAX. VALID PIXEL = GRAY Min <= PIXEL <= GRAY MAX PIXEL%= VALID PIXEL *100/TOTAL PIXEL OF REGION DATA OK=TH MIN <= PIXEL% <= TH MAX

Page 119: Á Á Á.proma Æ

119

PXVISION BROWSER

19.2.5 Test Start the test for check the acquired values

Values acquired for 3 Objects (in violet the invalid region)

Data show for selected Detector Pixel Detected Number of Valid Pixel detected in the region Pixel % Percentage Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

OBJECT TO DETECT

Page 120: Á Á Á.proma Æ

120

PXVISION BROWSER

19.3 Contrast Detector Search in a REGION a quantity of PIXEL that satisfy the parameters set. Normally used for detecting a presence of OBJECTS. The algorithm is based on compare the PIXELS CONTRAST. The contrast is calculated by Pixels quantity DARK (value <=127) and BRIGHT (value >127) and not from their position in the area. This function doesn’t detect the object position, but only the object presence. Contrast 100% Contrast 100% Contrast 20% Can be insert up to 20 CONTRAST DETECTOR for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.7 Fps

2048x1536 Pixel 5 Fps

1920x1080 Pixel 9.5 Fps

1600x1200 Pixel 6.9 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.6 Fps

1024x768 Pixel 12.6 Fps

800x600 Pixel 15 Fps

Page 121: Á Á Á.proma Æ

121

PXVISION BROWSER

19.3.1 Parameters The parameters can set for a maximum of 20 Contrast Detector

19.3.2 ThMin - ThMax PERCENTAGE interval for final data VALID. The calculation is made on all PIXELS of REGION counting the PIXELS DARK (value<=127) and the PIXELS BRIGHT (value>127), the INVALID REGION PIXELS will be excluded. CONTRAST%=VAL%(TOT DARK/TOT BRIGHT) DATA OK=TH MIN <= CONTRAST % <= TH MAX

Page 122: Á Á Á.proma Æ

122

PXVISION BROWSER

19.3.3 Test Start the test for check the acquired values

Values acquired for 3 Objects (1-2 Valid 3 not valid)

Data show for selected Detector Contrast CONTRAST value Dark Value Total of DARK pixels Bright Value Total of BRIGHT Pixels Pixel % Percentage Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

OBJECTS TO DETECT

Page 123: Á Á Á.proma Æ

123

PXVISION BROWSER

19.4 Brightness Detector Search in a REGION a quantity of PIXEL BRIGHT that satisfy the parameters set. Normally used for detecting a presence of OBJECTS. The algorithm is based on quantity of PIXELS BRIGHT, more pixels bright are detected, higher is the value. This function doesn’t detect the object position, but only the object presence. Can be insert up to 20 BRIGHTNESS DETECTOR for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.7 Fps

2048x1536 Pixel 4.9 Fps

1920x1080 Pixel 9.5 Fps

1600x1200 Pixel 7 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 11.8 Fps

1024x768 Pixel 12.5 Fps

800x600 Pixel 15 Fps

Page 124: Á Á Á.proma Æ

124

PXVISION BROWSER

19.4.1 Parameters The parameters can set for a maximum of 20 Brightness Detector

19.4.2 ThMin - ThMax PERCENTAGE interval for final data VALID. The calculation is made on all PIXELS of REGION, the INVALID REGION PIXELS will be excluded.

BRIGHTNESS=∑𝒏𝟎 BRIGHTNESS%=VAL%( BRIGHTNESS/TOT PIXEL) DATA OK=TH MIN <= BRIGHTNESS % <= TH MAX

Page 125: Á Á Á.proma Æ

125

PXVISION BROWSER

19.4.3 Test Start the test for check the acquired values

Values acquired for 3 Objects (1-2 Valid 3 not valid)

Data show for selected Detector Brightness % Brightness Percentage Pixel Detected Total of Pixels Acq Ok Number of valid acquisition Acq Err Number of invalid acquisition Sec Total time Fps Frames per second RESET Reset statistic data

OBJECTS TO DETECT

Page 126: Á Á Á.proma Æ

126

PXVISION BROWSER

19.5 Objects Color Detector Search in a REGION the OBJECTS from color. The search returns a list of objects detected. The color of object is set by HSV model or RGB model The HSV model is near to Human perception of color instead of RGB model. H HUE 0° RED 120° GREEN 240° BLUE 360° RED S SATURATION V VALUE

Can be insert up to 10 DETECTOR for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 3.6 Fps

2048x1536 Pixel 4.6 Fps

1920x1080 Pixel 8.1 Fps

1600x1200 Pixel 5.6 Fps

1280x1024 Pixel 7 Fps

1280x720 Pixel 10.7 Fps

1024x768 Pixel 11.8 Fps

800x600 Pixel 15.1 Fps

Page 127: Á Á Á.proma Æ

127

PXVISION BROWSER

19.5.1 Parameters The parameters can set for a maximum of 10 Color Detector

19.5.2 H-R H or R value min and max. By the two SLIDERS is possible set the interval value from MIN and MAX.

The values can be set manually by the fields MIN and MAX and activated by button SET. By buttons FROM - TO can be acquired the color value from MOUSE Press the button, move the mouse cursor on the color of image and press left button mouse

19.5.3 S-G S or G value MIN and MAX.

19.5.4 V-B V or B value MIN and MAX.

19.5.5 From mouse By Button “Mouse” acquire a rectangular region of image where there are the colour desired, automatically all parameters are set.

MIN MAX

Page 128: Á Á Á.proma Æ

128

PXVISION BROWSER

19.5.6 Check Color If it is checked the REAL image will be shown. If it is unchecked will be shown an image in BLACK and WHITE relative to the result of HSV values set. The OBJECTS detected will be of WHITE COLOR. This allows to set the parameters HSV because the results are visible.

19.5.7 Show Contour Show objects contours.

19.5.8 Show Rect Show the RECTANGLE of containment of object. By center of gravity is detected the angle of object

19.5.9 RGB-HSV

By checkbox is possible to set the model RGB or HSV

OBJECT DETECTED ON RED COLOR As see the objects not detected aren’t visible

Page 129: Á Á Á.proma Æ

129

PXVISION BROWSER

19.5.10 Test Start the test for check the acquired values

Values acquired for 3 DETECTOR 1 on RED 2 on GREEN 3 on BLUE

Data show for selected Detector Cx,Cy,Angle Objects List - Center X,Y and Angle Area Objects List - Area W,H Objects List – Width,Heght Acq Err Number of invalid acquisitions Sec Total time Fps Frames per second RESET Reset statistic data PIXEL PIXEL/MM

Page 130: Á Á Á.proma Æ

130

PXVISION BROWSER

19.6 Objects Area Detector Search in a REGION the OBJECTS from area value. The search returns a list of objects detected. Can be insert up to 10 DETECTOR for a single section.

Fps – Frames per second (the data could change by camera parameters settings)

Camera Resolution Fps

2592x1944 Pixel 4.8 Fps

2048x1536 Pixel 6.3 Fps

1920x1080 Pixel 9.6 Fps

1600x1200 Pixel 7.6 Fps

1280x1024 Pixel 7.2 Fps

1280x720 Pixel 14 Fps

1024x768 Pixel 16.1 Fps

800x600 Pixel 16.3 Fps

Page 131: Á Á Á.proma Æ

131

PXVISION BROWSER

19.6.1 Parameters The parameters can set for a maximum of 10 Area Detector

19.6.2 Show Contour Show objects contours.

19.6.3 Show Rect Show the RECTANGLE of containment of object.

Page 132: Á Á Á.proma Æ

132

PXVISION BROWSER

19.6.4 Test Start the test for check the acquired values

Values acquired for 2 DETECTOR 1 RECTANGLE AREA - 2 FREE AREA

Data show for selected Detector Cx,Cy,Angle Objects List - Center X,Y and Angle Area Objects List - Area W,H Objects List – Width,Heght Acq Err Number of invalid acquisitions Sec Total time Fps Frames per second RESET Reset statistic data PIXEL PIXEL/MM

Page 133: Á Á Á.proma Æ

133

PXVISION BROWSER

20 Find Contours This function allows to detect the Objects CONTOURS and convert the paths in Gcode or DXF. This function use many parameters for get the best contours of the objects. The paths found are immediately visible for check the final result. The process is starting from an IMAGE ACQUISITION up to the best algorithm for generate the final path The FILTERS are mandatory for get a good result.

Page 134: Á Á Á.proma Æ

134

PXVISION BROWSER

20.1 Parameters

20.1.1 Image Acquisition After starting TEST capture an image by button ACQ IMAGE. Immediately the path contours are visible.

20.1.2 Continous Update If checked the path contours are generated in Real time each time the parameters are changed. If the paths are complex, is advisable uncheck this parameter because it could slowly of system. The button REFRESH allows to see the results if the parameter is unchecked.

Page 135: Á Á Á.proma Æ

135

PXVISION BROWSER

20.1.3 Show Hierarchy If checked the HIERARCHY of paths found is shown. The HIERARCHY start from external paths and continue to internal paths. The following example show the HIERARCHY: ROSSO HIERARCHY 1 BLU HIERARCHY 2 VERDE HIERARCHY 3 By the HIERARCHY is possible eliminate some paths from final result.

20.1.4 Show Only Path If checked are shown ONLY PATHS FOUND without background image.

20.1.5 I/O Remove Mode Allows to remove the EXTERNAL or INTERNAL paths by some algorithms. Sample Image

Page 136: Á Á Á.proma Æ

136

PXVISION BROWSER

Internal % Min All path CHILD of a HIERARCHY (i.e. 2 with father 1) that have a percentage length <= to parameter In/Out Tolerance are removed

In Out Tolerance=38 the paths 5,4,2 have been removed

Internal % Max All path FATHER of a HIERARCHY (i.e. 2 with father 1) that have a percentage length <= to

parameter In/Out Tolerance are removed In Out Tolerance=38 the paths 1,3 have been removed

Page 137: Á Á Á.proma Æ

137

PXVISION BROWSER

All Internal All paths CHILDS will be removed

HierarchyInterval Will be removed all paths outside the interval set in From H To H From H=1 To H=3

None Any Path will be not removed

Page 138: Á Á Á.proma Æ

138

PXVISION BROWSER

20.1.6 Chain Mode Defines the algorithm for found the paths. Normally is set to SIMPLE for get the best results.

20.1.7 Refresh Image Button for refresh the paths founded.

20.1.8 Edit Image Allows to remove manually some paths. After selected click with left button mouse on the path to REMOVE

20.1.9 Del Path Remove the selected paths.

20.1.10 Undo Undelete the paths removed.

20.1.11 Min Length All paths with LENGTH less to MIN LENGTH (PIXEL) are EXCLUDED Min Length=724 the paths 5,4,3 have been removed

Page 139: Á Á Á.proma Æ

139

PXVISION BROWSER

20.1.12 Max Length All paths with LENGTH greater to MAX LENGTH (PIXEL) are EXCLUDED Max Length=3000 the paths 1,2, have been removed

20.1.13 Nurbs Res N.U.R.B.S. (Non Uniform Rational Basis-Splines) Allows to convert the path segments in B Spline for smoothing the edges. Nurbs Res=0

Nurbs Res=3.8

20.1.14 Spline Order Defines the B SPLINE order for N.U.R.B.S. Higher values greater smoothing. Nurbs Res=3.8 Spline Order=3

Nurbs Res=3.8 Spline Order=7

Page 140: Á Á Á.proma Æ

140

PXVISION BROWSER

20.1.15 PolyLine Res Defines the POLYLINE RESOLUTION for paths find. Lower is the resolution, greater is the path definition. PolyLine Res=0.00038

PolyLine Res=0.002

20.1.16 Smoothing Allows the SMOOTHING of the paths. Eliminates noise peaks Works with low value of PolyLine Res. Lower values greater smoothing. Smoothing=0FF

Smoothing=0.094

20.1.17 Angle Line Reduction Allows to reduce the segments number based on Angle get from two consecutive segments. If the Angle is <= Angle Line Red the two segments will reduced in one only. The parameter value is in DEGREES Angle Line Red=0FF

Angle Line Red=26 Degrees

Page 141: Á Á Á.proma Æ

141

PXVISION BROWSER

20.1.18 Length Line Reduction Allows to reduce the segments number based on Line length. If the Line Length is <= Length Line Red the segment will be removed. Length Line Red=0FF

Length Line Red=11

Page 142: Á Á Á.proma Æ

142

PXVISION BROWSER

20.2 Gcode Converter Configuration First to use, the Gcode Converter is necessary configure it for adapting to NC machine used. Isn’t explained the Gcode file processing, but only the parameters setting. Open the Tab Gcode Convert.

20.2.1 Invert X-Y Axis If checked the relative values of Axis will be inverted.

20.2.2 Gcode Start Gcode instructions that will be inserted to START the file.

20.2.3 Gcode End Gcode instructions that will be inserted to END the file.

20.2.4 Gcode Tool Up Gcode instructions that will be inserted each TOOL UP - PATH CHANGED

20.2.5 Gcode Tool Down Gcode instructions that will be inserted each TOOL DOWN – WORK NEW PATH

20.2.6 Export Button for Export the paths in a Gcode file.

Page 143: Á Á Á.proma Æ

143

PXVISION BROWSER

20.3 DXF Converter Configuration There aren’t parameters for configure the DXF Converter.

20.3.1 Invert X-Y Axis If checked the relative values of Axis will be inverted.

20.3.2 Export Button for Export the paths in a DXF file.

Page 144: Á Á Á.proma Æ

144

PXVISION BROWSER

20.4 Test After start Test press button ACQ IMAGE for capture a valid image Select the parameters for check the paths conversion.

Page 145: Á Á Á.proma Æ

145

PXVISION BROWSER

21 BarCode Reader Allows to read BarCode and QrCode. Normally for this function isn’t necessary any filter. The BarCode or QrCode to read must have a good visbility The BarCode must have an alignament of 0 or 90 degrees referred to camera view

The QrCode can be in any position.

The BarCode and QrCode detection is automatically.

Page 146: Á Á Á.proma Æ

146

PXVISION BROWSER

21.1 Parameters For this function only parameter is present AutoRotate, if checked allows to find the BarCode with orientation to 0 or 90 Degrees. Is advisable the REGION definition.

21.1.1 Test Start the test

Code Code read from BarCode or QrCode Format Code Code Format Additional Data Additional data ex. Country, Orientation etc. (if available)

Page 147: Á Á Á.proma Æ

147

PXVISION BROWSER

22 OCR Reader Allows to read TEXT. Can be used the FILTERS for contrast increase.

PROMAX SRL VIA NEWTNO,5G CASTELFIORENTINO (FI) ITALY PHONE: (+39) 0571684620 WWW.PROMAX.IT [email protected]

Page 148: Á Á Á.proma Æ

148

PXVISION BROWSER

22.1 Parameters The results of reader is based on a SCORE from 0 to 100. Values >= 85 means a good text read. Is advisable the REGION definition.

22.1.1 Language Is referred to language of text to read. Can be set always to eng”.

22.1.2 Engine Mode Defines the algorithm for text search. Select the Engine Mode that produce a higher SCORE%. Normally TESSERACTONLY is the best

22.1.3 Score Ok Insert the SCORE value % for accepting the data Ok. Values of SCORE lower this means the read text not Ok

22.1.4 Test Start the test

Testo rilevato correttamente

Page 149: Á Á Á.proma Æ

149

PXVISION BROWSER

The text read is shown in the field

Score % SCORE percentage for the text read Acq Ok Number of valid acquisitions Acq Err Number of invalid acquisitions Sec Total time Fps Frames per second

Page 150: Á Á Á.proma Æ

150

PXVISION BROWSER

23 JOBS The JOBS are the PXVISION CONFIGURATIONS that can loaded in run time during process acquisition. All Jobs derive from a base configuration “PxVision.cfg” and after saved in a file name. When a JOB is loaded, the Camera parameters aren’t changed (Brightness, Resolution etc.), but only the functions parameters, Filters etc. are changed. So is possible parametrization for the functions.

23.1 Save a JOB From Menu JOBS choose Save Job File . Insert the JOB name without any extension and press button OK.

The JOBS are saved in the folder PxVisionJobs

23.2 Load a JOB From Menu JOBS choose Load Job File . Insert the JOB name and press button OK. The new parametrization will be activated.

Page 151: Á Á Á.proma Æ

151

PXVISION BROWSER

24 Camera Correction This function is very complex to use. Allows to correct the LENS distortions (ex. FishEye). By this function can correct some distortions not BIG. Normally the distortions are present in the camera borders The following image is made with LENS 8mm, distance 8 Cm from the object

Page 152: Á Á Á.proma Æ

152

PXVISION BROWSER

24.1 Parameters There are many parameters and of complex use.

Page 153: Á Á Á.proma Æ

153

PXVISION BROWSER

24.1.1 Enable Camera Correction If checked the correction is enabled. The image could be deformed and no visble.

24.1.2 Parameters setting First to all can be insert the known parameters. Ex: Camera used resolution 1600x1200 pixel. The parameters can insert in the field and activated by button CR of key board.

In the field INC can insert the increment value for the buttons - and +

The SKEW parameter is used only for correction the CAMERA mounting FX Insert the resolution PIXEL X CAMERA 1600 FY Insert the resolution PIXEL Y CAMERA 1200 CX Insert the center of CAMERA PIXEL X 800 CY Insert the center of CAMERA PIXEL Y 600

Now is possible to set the PARAMETERS K1,K2,K3,P1,P2 for correct the image. Enable the grid view as help to align the image

In the border there is a low distortion, but generally the image has been corrected

Page 154: Á Á Á.proma Æ

154

PXVISION BROWSER

Index 1 PREFACE .................................................................................................................................... 3

2 PxVisionBrowser Execution ........................................................................................................ 9

2.1 Execution ............................................................................................................................... 9

2.2 Choice of Startup configuration ............................................................................................ 9

2.3 Create a new configuration.................................................................................................... 9

2.4 Delete a Configuration .......................................................................................................... 9

2.5 Run by command line and arguments ................................................................................... 9

2.6 Check Updates ..................................................................................................................... 10

3 Unlock Windows Firewall ......................................................................................................... 11

4 Home Screen .............................................................................................................................. 14

5 Camera Calibration .................................................................................................................... 15

5.1 Camera Setting .................................................................................................................... 15

5.2 General Parameters.............................................................................................................. 16

5.2.1 New Camera IP Address .............................................................................................. 16

5.2.2 Camera Rotation Angle Correction .............................................................................. 17

5.2.3 Save Parameters ........................................................................................................... 17

5.2.4 Default Parameters ....................................................................................................... 17

5.2.5 Camera Parameters ...................................................................................................... 17

5.2.6 Filterings Visualization ................................................................................................ 18

5.2.7 Camera Colors Correction ........................................................................................... 19

6 Image Source.............................................................................................................................. 20

7 Image Filtering ........................................................................................................................... 21

7.1 Binary Threshold ................................................................................................................. 22

7.2 Blur Filters ........................................................................................................................... 28

7.3 Filters for find contours ....................................................................................................... 30

7.4 Brightness and Contrast filters ............................................................................................ 31

8 Region and Border image .......................................................................................................... 32

8.1 Capture a Region ................................................................................................................. 32

8.2 Border Definition ................................................................................................................ 33

9 Mask Definition ......................................................................................................................... 34

9.1 Mask Capture ...................................................................................................................... 34

9.2 Region Definition for Mask ................................................................................................ 36

9.3 Mode Frame ........................................................................................................................ 36

9.4 Mask Mode .......................................................................................................................... 36

9.4.1 AbsDiff ......................................................................................................................... 36

Page 155: Á Á Á.proma Æ

155

PXVISION BROWSER

9.4.2 Add ............................................................................................................................... 37

9.4.3 BitwiseAnd................................................................................................................... 37

9.4.4 BitwiseOr ..................................................................................................................... 37

9.4.5 BitwiseXor ................................................................................................................... 37

9.4.6 BitwiseNot ................................................................................................................... 38

9.4.7 Max .............................................................................................................................. 38

9.4.8 Min ............................................................................................................................... 38

9.4.9 Subract ......................................................................................................................... 38

9.4.10 CompareEqual .............................................................................................................. 39

9.4.11

CompareGreaterEqual,CompareGreaterThan,CompareLessEqual,CompareLessThan,

CompareNotEqual ...................................................................................................................... 39

10 Illumination LED ....................................................................................................................... 40

10.1 S.O. .................................................................................................................................. 40

10.2 LED On ............................................................................................................................ 40

11 Conversion Factor Pixel mm...................................................................................................... 41

11.1 Get the Conversion Factor ................................................................................................... 41

12 Utility ......................................................................................................................................... 43

12.1 Grid .................................................................................................................................. 43

12.1.1 Center Circular Grid..................................................................................................... 43

12.1.2 Mobile Circular Grid .................................................................................................... 43

12.1.3 Linear Grid ................................................................................................................... 44

12.1.4 Square Grid .................................................................................................................. 44

12.2 Capture ............................................................................................................................. 45

12.2.1 Crop Image ................................................................................................................... 45

12.2.2 Full Image .................................................................................................................... 45

12.3 Measure ............................................................................................................................ 45

12.3.1 Line .............................................................................................................................. 45

12.3.2 Rectangle ...................................................................................................................... 45

12.3.3 Circle ............................................................................................................................ 46

12.4 Image Zoom ..................................................................................................................... 46

12.4.1 From Mouse Wheel ...................................................................................................... 46

12.4.2 By Menù ....................................................................................................................... 46

12.5 Show Image Data ............................................................................................................. 46

13 Ethernet Server ........................................................................................................................... 47

13.1 Server Parameters ............................................................................................................ 47

14 PxVision functions available ...................................................................................................... 48

Page 156: Á Á Á.proma Æ

156

PXVISION BROWSER

15 Marker Detection ....................................................................................................................... 49

15.1 Circular Marker ............................................................................................................... 50

15.1.1 Parameters .................................................................................................................... 51

15.1.2 Marker Diameter .......................................................................................................... 51

15.1.3 Tolerance ...................................................................................................................... 51

15.1.4 Accuracy ...................................................................................................................... 51

15.1.5 Diameter % .................................................................................................................. 52

15.1.6 Pixel Noise ................................................................................................................... 52

15.1.7 Pixel Pressure ............................................................................................................... 52

15.1.8 Black Value .................................................................................................................. 53

15.1.9 White Value .................................................................................................................. 53

15.1.10 Test ........................................................................................................................... 54

15.2 Square Marker ................................................................................................................. 55

15.2.1 Parameters .................................................................................................................... 56

15.2.2 Width/Heigth ................................................................................................................ 56

15.2.3 Tolerance ...................................................................................................................... 56

15.2.4 Accuracy ...................................................................................................................... 56

15.2.5 Test ............................................................................................................................... 57

15.3 Type 1 Marker .................................................................................................................. 58

15.3.1 Parameters .................................................................................................................... 59

15.3.2 Marker Diameter .......................................................................................................... 59

15.3.3 Tolerance ...................................................................................................................... 59

15.3.4 Accuracy ...................................................................................................................... 59

15.3.5 Diameter % .................................................................................................................. 59

15.3.6 Pixel Noise ................................................................................................................... 59

15.3.7 Pixel Pressure ............................................................................................................... 59

15.3.8 Black Value .................................................................................................................. 59

15.3.9 White Value .................................................................................................................. 59

15.3.10 Test ........................................................................................................................... 60

15.4 Hole Marker ..................................................................................................................... 61

15.4.1 Parameters .................................................................................................................... 62

15.4.2 Hole Diameter .............................................................................................................. 62

15.4.3 Tolerance ...................................................................................................................... 62

15.4.4 Test ............................................................................................................................... 63

15.5 Find Match ....................................................................................................................... 64

15.5.1 Capture a Sample image .............................................................................................. 64

15.5.2 Parameters .................................................................................................................... 66

Page 157: Á Á Á.proma Æ

157

PXVISION BROWSER

15.5.3 Model Image ................................................................................................................ 66

15.5.4 Region Ok .................................................................................................................... 66

15.5.5 Delta Region Ok.................................................. Errore. Il segnalibro non è definito.

15.5.6 Score Ok ....................................................................................................................... 66

15.5.7 Delta Score Ok .................................................... Errore. Il segnalibro non è definito.

15.5.8 Test ............................................................................................................................... 68

16 Measures .................................................................................................................................... 69

16.1 Common Parameters ........................................................................................................ 69

16.1.1 DARK .......................................................................................................................... 69

16.1.2 Inside ............................................................................................................................ 69

16.1.3 Pixel Noise ................................................................................................................... 70

16.1.4 Pressure High/Low ....................................................................................................... 70

16.1.5 Gray Value .................................................................................................................... 70

16.2 Cross Section ................................................................................................................... 71

16.2.1 Parameters .................................................................................................................... 72

16.2.2 Probe Add/Remove ...................................................................................................... 72

16.2.3 Select a Probe ............................................................................................................... 72

16.2.4 Probe Position .............................................................................................................. 72

16.2.5 Test ............................................................................................................................... 74

16.3 Gap Cross Section ............................................................................................................ 75

16.3.1 Parameters .................................................................................................................... 76

16.3.2 Probe Add/Remove ...................................................................................................... 76

16.3.3 Select a Probe ............................................................................................................... 76

16.3.4 Probe Position .............................................................................................................. 76

16.3.5 Min Gap ....................................................................................................................... 77

16.3.6 Test ............................................................................................................................... 78

16.4 Calliper ............................................................................................................................ 88

16.4.1 Parameters .................................................................................................................... 89

16.4.2 Calliper Add/Remove ................................................................................................... 89

16.4.3 Select a Calliper ........................................................................................................... 89

16.4.4 Calliper Position ........................................................................................................... 89

16.4.5 Test ............................................................................................................................... 91

16.5 Fit Line ............................................................................................................................. 92

16.5.1 Parameters .................................................................................................................... 93

16.5.2 Fit Line Add/Remove ................................................................................................... 93

16.5.3 Select a Fit Line ........................................................................................................... 93

16.5.4 Fit Line Position ........................................................................................................... 93

Page 158: Á Á Á.proma Æ

158

PXVISION BROWSER

16.5.5 Select a Find Mode ...................................................................................................... 94

16.5.6 Step............................................................................................................................... 94

16.5.7 Test ............................................................................................................................... 95

16.6 Fit Circle .......................................................................................................................... 96

16.6.1 Parameters .................................................................................................................... 97

16.6.2 Fit Circle Add/Remove ................................................................................................ 97

16.6.3 Select a Fit Circle ......................................................................................................... 97

16.6.4 Fit Circle Position ........................................................................................................ 97

16.6.5 Select a Find Mode ...................................................................................................... 99

16.6.6 Step............................................................................................................................... 99

16.6.7 Test ............................................................................................................................. 100

17 Probe ........................................................................................................................................ 101

17.1 Common Parameters ...................................................................................................... 101

17.1.1 DARK ........................................................................................................................ 101

17.1.2 Pixel Noise ................................................................................................................. 101

17.1.3 Pressure ...................................................................................................................... 101

17.1.4 Gray Value .................................................................................................................. 101

17.2 Probe Single Point ......................................................................................................... 102

17.2.1 Parameters .................................................................................................................. 103

17.2.2 Probe Add/Remove .................................................................................................... 103

17.2.3 Select a Probe ............................................................................................................. 103

17.2.4 Probe Position ............................................................................................................ 103

17.2.5 Test ............................................................................................................................. 105

17.3 Probe Line ...................................................................................................................... 106

17.3.1 Parameters .................................................................................................................. 107

17.3.2 Probe Add/Remove .................................................................................................... 107

17.3.3 Select a Probe ............................................................................................................. 107

17.3.4 Probe Position ............................................................................................................ 107

17.3.5 Test ............................................................................................................................. 109

18 Detector .................................................................................................................................... 114

18.1 Common Parameters ...................................................................................................... 114

18.1.1 Region for Gray – Contrast - Brightness ................................................................... 114

18.1.2 Region for Objects Color – Objects Area .................................................................. 114

18.1.3 Invalid Region for Gray – Contrast - Brightness ....................................................... 115

18.1.4 RGB Channel for Gray – Contrast - Brightness ........................................................ 115

18.1.5 Detector Add/Remove ................................................................................................ 115

18.1.6 Select a Detector ........................................................................................................ 115

Page 159: Á Á Á.proma Æ

159

PXVISION BROWSER

18.1.7 Detector position for Gray – Contrast - Brightness ................................................... 116

18.1.8 Type Area for Objects Color – Objects Area ............................................................. 116

18.2 Gray Detector ................................................................................................................. 117

18.2.1 Parameters .................................................................................................................. 118

18.2.2 Gray Min .................................................................................................................... 118

18.2.3 Gray Max – Gray Detector ......................................................................................... 118

18.2.4 ThMin - ThMax ......................................................................................................... 118

18.2.5 Test ............................................................................................................................. 119

18.3 Contrast Detector ........................................................................................................... 120

18.3.1 Parameters .................................................................................................................. 121

18.3.2 ThMin - ThMax ......................................................................................................... 121

18.3.3 Test ............................................................................................................................. 122

18.4 Brightness Detector ....................................................................................................... 123

18.4.1 Parameters .................................................................................................................. 124

18.4.2 ThMin - ThMax ......................................................................................................... 124

18.4.3 Test ............................................................................................................................. 125

18.5 Objects Color Detector .................................................................................................. 126

18.5.1 Parameters .................................................................................................................. 127

18.5.2 H ................................................................................................................................. 127

18.5.3 S ................................................................................................................................. 127

18.5.4 V ................................................................................................................................. 127

18.5.5 Check Color ............................................................................................................... 128

18.5.6 Show Contour ............................................................................................................ 128

18.5.7 Show Rect .................................................................................................................. 128

18.5.8 Test ............................................................................................................................. 129

18.6 Objects Area Detector .................................................................................................... 130

18.6.1 Parameters .................................................................................................................. 131

18.6.2 Show Contour ............................................................................................................ 131

18.6.3 Show Rect .................................................................................................................. 131

18.6.4 Test ............................................................................................................................. 132

19 Find Contours ........................................................................................................................... 133

19.1 Parameters ...................................................................................................................... 134

19.1.1 Image Acquisition ...................................................................................................... 134

19.1.2 Continous Update ....................................................................................................... 134

19.1.3 Show Hierarchy.......................................................................................................... 135

19.1.4 Show Only Path ......................................................................................................... 135

19.1.5 I/O Remove Mode ...................................................................................................... 135

Page 160: Á Á Á.proma Æ

160

PXVISION BROWSER

19.1.6 Chain Mode ................................................................................................................ 138

19.1.7 Refresh Image ............................................................................................................ 138

19.1.8 Edit Image .................................................................................................................. 138

19.1.9 Del Path ...................................................................................................................... 138

19.1.10 Undo ....................................................................................................................... 138

19.1.11 Min Length ............................................................................................................. 138

19.1.12 Max Length ............................................................................................................ 139

19.1.13 Nurbs Res ............................................................................................................... 139

19.1.14 Spline Order ........................................................................................................... 139

19.1.15 PolyLine Res .......................................................................................................... 140

19.1.16 Smoothing .............................................................................................................. 140

19.1.17 Angle Line Reduction ............................................................................................ 140

19.1.18 Length Line Reduction ........................................................................................... 141

19.2 Gcode Converter Configuration .................................................................................... 142

19.2.1 Invert X-Y Axis .......................................................................................................... 142

19.2.2 Gcode Start ................................................................................................................. 142

19.2.3 Gcode End .................................................................................................................. 142

19.2.4 Gcode Tool Up ........................................................................................................... 142

19.2.5 Gcode Tool Down ...................................................................................................... 142

19.2.6 Export ......................................................................................................................... 142

19.3 DXF Converter Configuration ....................................................................................... 143

19.3.1 Invert X-Y Axis .......................................................................................................... 143

19.3.2 Export ......................................................................................................................... 143

19.4 Test ................................................................................................................................. 144

20 BarCode Reader ....................................................................................................................... 145

20.1 Parameters ...................................................................................................................... 146

20.1.1 Test ............................................................................................................................. 146

21 OCR Reader ............................................................................................................................. 147

21.1 Parameters ...................................................................................................................... 148

21.1.1 Language .................................................................................................................... 148

21.1.2 Engine Mode .............................................................................................................. 148

21.1.3 Score Ok ..................................................................................................................... 148

21.1.4 Test ............................................................................................................................. 148

22 JOBS ........................................................................................................................................ 150

22.1 Save a JOB ..................................................................................................................... 150

22.2 Load a JOB .................................................................................................................... 150

23 Camera Correction ................................................................................................................... 151

Page 161: Á Á Á.proma Æ

161

PXVISION BROWSER

23.1 Parameters ...................................................................................................................... 152

23.1.1 Enable Camera Correction ......................................................................................... 153

23.1.2 Parameters setting ...................................................................................................... 153