· product dimensions performances DER3/0I 96x96x51 1 intervention threshold - control of opening...
Transcript of · product dimensions performances DER3/0I 96x96x51 1 intervention threshold - control of opening...
product dimensions performancesDER3/0I 96x96x51 1 intervention threshold - control of opening coil - auto-diagnostic by led
DER3/0E 48x48x94 1intervention threshold - control of opening coil - auto-dignostic by led
DER3/1I 96x96x51 digital display - 1intervention threshold - 2contemporary contacts NO-C-NC - control of opening coil - auto-diagnostic by display - limit time of no-intervention 10 sec
DER3/2I 96x96x51 digital display - 2 thresholds:intervention + alarm - 2 contacts NO-C-NC - control of opening coil - auto-diagnostic by display - test without intervention of opening coil - limit time of no-intervention 10 sec
DER3/2IRS 96x96x51 digital display - 2 thresholds:intervetnion+alarm - 2 contacts NO-C-NC - control of opening coiL - auto-diagnostic by display - test without intervention of opening coil - serial outputs: RS232 or RS485 - limit time of no-intervention 10 sec
DER3/2IM 96x96x51 display - 2 thresholds: intervention +alarm - 2 contacts NO-C-NC - intervention memory - control of opening coil - auto-diagnostic by display - test without intervention of opening coil - limit time of no-intervention 10 sec
DER3/2IMRS 96x96x51 digital display - 2 thresholds: intervention +alarm - 2 contacts NO-C-NC - intervention memory - control of opening coil - auto-diagnostic by display - test without intervention of opening coil - serial outputs: RS232 or RS485 - limit time of no-intervention 10 sec
product dimensions performancesDER3/0D 2 DIN 1 intervention threshold - control of opening coil - auto-diagnostic by led
DER3/1D 3 DIN display - 1 intervention threshold - 2 contemporary contacts NO-C-NC control of opening coil - auto-diagnostic by display - limit time of no-intervention 10 sec
DER3/1DL 3 DIN display - 1 intervention threshold - 2 indipendent contacts NO-C-NC - 3 times automatic reset - control of opening coil - auto-diagnostic by display - limit time of no-intervention 10 sec
DER3/2D 3 DIN display - 2 thresholds: intervention+alarm - 2 contacts NO-C-NC - control of opening coil - auto-diagnostic by display - test without intervention of coil - limit time of no-intervention 10 sec
DER3/2DRS 3 DIN display - 2 thresholds : intervention+alarm - 2 contacts NO-C-NC - control of opening coil - auto-diagnostic by display - test without intervention of opening coil - serial output: RS232 or RS485 - limit time of no-intervention 10 sec
Type DER3/0D DER3/1DAuxiliary voltage (Vac) 48÷230 Vac / 400 Vac (-15% / +10%) cod.9DER3/0D cod.9DER3/1DAuxiliary voltage (Vdc) 24÷230 Vdc (-15% / +10%) cod.9DER3/0DCC cod.9DER3/1DCCToroidal transducers series D (opened and closed) • •Overall dimensions --- 2 DIN modules 3 DIN modulesWeight --- 200 gr 250 grCalibration Field IΔn from 0,03 A to 30 A • •Intervention Field IΔn from 80% IΔn to 100% IΔn • •Calibration Field Δt instantaneous and from 0,06 sec to 5 sec
instantaneous and from 0,06 sec to 10 sec•
------•
Regulation Method continuous • •Operational Elements buttons and potentiometers
buttons and display•
------•
Visualization led e indicatorsdisplay dots matrix
•---
---•
Visualization Mode of differential current measurement (only for type with display)
Numeric Visualization from 0,03 A to 30 AVisualization with bargraph in percentage from 0 to 100% IΔn
------
•---
Output contacts n° 1 NO-C-NC 5A 250 Vacn° 2 NO-C-NC 5A 250 Vac
•---
---•
Intervention Mode of output contacts final trip (single contact)final trip (double contact)alarm3 times automatic reset
•---------
---•
------
Alarm calibration field from 20%IΔn to 80%IΔn --- ---Test criteria simulation of max. IΔn thanks to additional excitation
winding present into toroidal transducer • •
Test and Reset test of trip relay and opening of circuit breaker Reset- manual or automaticspecial test with simulation of tripping without opening of relay and switch
•
---
•
---
Serial output (option) RS232 / RS485 --- --- Intervention Memory visualization by display --- ---Self-control of connections and inboard electronics
permanent verification of: connection, orientation and windings of toroidal transducer, inboard electronics, voltage presence
• •
Self-control of opening coil continuity and electric wiring of opening coil • •Self-control of auxiliary voltage Permanent (positive safe selectionable) • •Networks to be controlled BT< 1000V 50/60 Hz • •Distribution system TT, TN • •Class A, AC • •Standards reference IEC 60947-2 :2006 annexM ed4°
CEI-EN 60947-2 annex. M - edition 8°• •
Measurement Mode RMS • •Max Consumption 3 VA • •Insulation Class (front) II • •Degree of protection IP50 (frontal), IP20 (terminals) • •Self- Extinguishing case cl. V0 • •Conversion Table: Previous Models and Codes (AC Voltage) DER2/D2B cod.9DR60NB DER2/D2B cod.9DR60NB
DER2/DCS cod.9DR110N
DER3/1DL DER3/2D DER3/0E DER3/0I DER3/1I DER3/2I DER3/2IMcod.9DER3/1DL cod.9DER3/2D cod.9DER3/0E cod.9DER3/0I cod.9DER3/1I cod.9DER3/2I cod.9DER3/2IM
cod.9DER3/1DLCC cod.9DER3/2DCC cod.9DER3/0ECC cod.9DER3/0ICC vcod.9DER3/1ICC cod.9DER3/2ICC cod.9DER3/2IMCC• • • • • • •
3 DIN modules 3 DIN modules 48x48x94 96x96x51 96x96x51 96x96x51 96x96x51250 gr 250 gr 200 gr 200 gr 250 gr 250 gr 250 gr
• • • • • • •• • • • • • •
---•
---•
•---
•---
---•
---•
---•
• • • • • • •---•
---•
•---
•---
---•
---•
---•
---•
---•
•---
•---
---•
---•
---•
••
••
------
------
•---
••
••
---•
---•
•---
•---
---•
---•
---•
---------•
---••
---
•---------
•---------
---•
------
---••
---
---••
------ • --- --- --- • •• • • • • • •
•
---
•
•
•
---
•
---
•
---
•
•
•
•
--- cod. +RS485 or RS232 --- --- --- cod. +RS485 or RS232 cod. +RS485 or RS232--- --- --- --- --- --- •
• • • • • • •
• • • • • • •--- • • • • • •• • • • • • •• • • • • • •• • • • • • •• • • • • • •
• • • • • • •• • • • • • •• • • • • • •• • • • • • •• • • • • • •
DER2/D3LB cod.9DR48NLB
DER2/D2B cod.9DR60NBDER2/DCS cod.9DR11ONDER2/D3B cod.9DR65NB
DER2/E cod.9DR80N DER2/I cod.9DR70N DER2/I cod.9DR70NDER2/ICS cod.9DR115N
DER2/I cod.9DR70NDER2/ICS cod.9DR115NDER2/K cod.9DR90NDER2/V cod.9DR100N
DER2/I cod.9DR70NDER2/ICS cod.9DR115NDER2/K cod.9DR90NDER2/V cod.9DR100NDER2/KM cod.9DR95NDER2/VM cod.9DR105N
product ordering code description
DRFILTRO 9DRFILTRO Filter for earth differential relay network disturbances (series DER3 )
D80S 9D80S Adder toroidal transducer for DER of CT present in line - see on pag. 12
D300M 9D300M Multiplier toroidal transducer: calibration field of DER from 0,03/30A to 0,30/300A - see on pag. 12
MULTILOG 9MULTILOG Datalogger that records informations of DER operation - see on pag. 46
DER3/0E 9DER3/0E
9DER3/0ECC
48x48x94
48x48x94
48÷230Vac / 400 Vac
24÷230Vdc
product ordering code dimensions auxiliary power supply voltage
DER3/0I 9DER3/0I
9DER3/0ICC
96x96x51
96x96x51
48÷230Vac / 400 Vac
24÷230Vdc
DER3/1DL 9DER3/1DL
9DER3/1DLCC
3 DIN
3 DIN
48÷230Vac / 400 Vac
24÷230Vdc
DER3/1D 9DER3/1D
9DER3/1DCC
3 DIN
3 DIN
48÷230Vac / 400 Vac
24÷230Vdc
DER3/1I 9DER3/1I
9DER3/1ICC
96x96x51
96x96x51
48÷230Vac / 400 Vac
24÷230Vdc
DER3/2IM 9DER3/2IM
9DER3/2IMRS232
9DER3/2IMRS485
9DER3/2IMCC
9DER3/2IMCCRS232
9DER3/2IMCCRS485
96x96x51
96x96x51
96x96x51
96x96x51
96x96x51
96x96x51
48÷230Vac / 400 Vac
48÷230Vac / 400 Vac
48÷230Vac / 400 Vac
24÷230Vdc
24÷230Vdc
24÷230Vdc
DER3/2D 9DER3/2D
9DER3/2DRS232
9DER3/2DRS485
9DER3/2DCC
9DER3/2DCCRS232
9DER3/2DCCRS485
3 DIN
3 DIN
3 DIN
3 DIN
3 DIN
3 DIN
48÷230Vac / 400 Vac
48÷230Vac / 400 Vac
48÷230Vac / 400 Vac
24÷230Vdc
24÷230Vdc
24÷230Vdc
DER3/2I 9DER3/2I
9DER3/2IRS232
9DER3/2IRS485
9DER3/2ICC
9DER3/2ICCRS232
9DER3/2ICCRS485
96x96x51
96x96x51
96x96x51
96x96x51
96x96x51
96x96x51
48÷230Vac / 400 Vac
48÷230Vac / 400 Vac
48÷230Vac / 400 Vac
24÷230Vdc
24÷230Vdc
24÷230Vdc
DER3/0D 9DER3/0D
9DER3/0DCC
2 DIN
2 DIN
48÷230Vac / 400 Vac
24÷230Vdc