MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3
Transcript of MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3
![Page 1: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/1.jpg)
Enclosure Drip shield
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 3A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 94.0%
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure
11"
11"
11
1
2
"
11"
FRONT VIEW
SIDE VIEW
3
8
1
4
"
9
1
2
"
600
208Y / 120
220°C
150°C
55 / 25
(%z)
- CSA certified / UL listed
5.1
Dyn1(TT-1)
10KV
180W
24W
45dB
K.O.'S Ø1"
1"
14
1
2
"
![Page 2: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/2.jpg)
Enclosure Drip shield
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 3B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 94.0%
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- CSA enclosure: ventilated painted ASA 61gray
- Copper windings
- Copper ground strap between core/coil and enclosure
11"
11"
11
1
2
"
11"
FRONT VIEW
SIDE VIEW
3
8
1
4
"
9
1
2
"
480
208Y / 120
220°C
150°C
55 / 25
(%z)
- CSA certified / UL listed
5.1
Dyn1(TT-1)
10KV
180W
24W
45dB
K.O.'S Ø1"
1"
14
1
2
"
![Page 3: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/3.jpg)
MARCUS
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
13
1
16
"
21"18
3
16
" 18"
13
3
16
"
21"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 6A1-PTECHNICAL DATA
3-PHASE ISOLATING
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Impedance
Contractor
BIL.
6
10
1
2
"
19
1
4
"
FRONT VIEW SIDE VIEW
600
208Y / 120
220°C
150°C
85 / 39
Connection
(%z)
10KV
5.5
16
11
16
"
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"(TYP)
10
1
2
"
5
1
4
"
3
8
"
3
8
"
Dyn1(TT-1)
335W
35W
45dB
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
Efficiency = 94.1%
![Page 4: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/4.jpg)
MARCUS
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
13
1
16
"
21"18
3
16
" 18"
13
3
16
"
21"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 6B1-PTECHNICAL DATA
3-PHASE ISOLATING
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Impedance
Contractor
BIL.
6
10
1
2
"
19
1
4
"
FRONT VIEW SIDE VIEW
480
208Y / 120
220°C
150°C
85 / 39
Connection
(%z)
10KV
5.5
16
11
16
"
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"(TYP)
10
1
2
"
5
1
4
"
3
8
"
3
8
"
Dyn1(TT-1)
335W
35W
45dB
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
Efficiency = 94.1%
![Page 5: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/5.jpg)
13
1
16
"
21"18
3
16
" 18"
13
3
16
"
21"
10
1
2
"
19
1
4
"
FRONT VIEW SIDE VIEW
16
11
16
"
MOUNTING HOLE
Ø
3
4
(TYP)
Ø1"(TYP)
10
1
2
"
5
1
4
"
3
8
"
3
8
"
MARCUS
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 10A1-PTECHNICAL DATA
3-PHASE ISOLATING
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 94.8%
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Impedance
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
10
600
208Y / 120
220°C
150°C
110 / 50
Connection
(%z)
10KV
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
5.6
Dyn1(TT-1)
520W
42W
45dB
![Page 6: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/6.jpg)
13
1
16
"
21"18
3
16
" 18"
13
3
16
"
21"
10
1
2
"
19
1
4
"
FRONT VIEW SIDE VIEW
16
11
16
"
MOUNTING HOLE
Ø
3
4
(TYP)
Ø1"(TYP)
10
1
2
"
5
1
4
"
3
8
"
3
8
"
MARCUS
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 10B1-PTECHNICAL DATA
3-PHASE ISOLATING
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 94.8%
Primary connectors per phase : #14-#4
Secondary connectors per phase: #14-#4
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Impedance
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
10
480
208Y / 120
220°C
150°C
110 / 50
Connection
(%z)
10KV
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
5.6
Dyn1(TT-1)
520W
42W
45dB
![Page 7: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/7.jpg)
13
1
16
"
21"18
3
16
" 18"
13
3
16
"
21"
10
1
2
"
19
1
4
"
FRONT VIEW SIDE VIEW
16
11
16
"
MOUNTING HOLE
Ø
3
4
(TYP)
Ø1"
10
1
2
"
5
1
4
"
3
8
"
5
1
4
"
MARCUS
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 15A1-PTECHNICAL DATA
3-PHASE ISOLATING
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 97.48%
NEMA TP-1)
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Impedance
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
15
600
208Y / 120
220°C
150°C
170 / 78
Connection
(%z)
10KV
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
5.3
Dyn1(TT-1)
- Copper windings
861W
55W
45dB
![Page 8: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/8.jpg)
13
1
16
"
21"18
3
16
" 18"
13
3
16
"
21"
10
1
2
"
19
1
4
"
FRONT VIEW SIDE VIEW
16
11
16
"
MOUNTING HOLE
Ø
3
4
(TYP)
Ø1"
10
1
2
"
5
1
4
"
3
8
"
5
1
4
"
MARCUS
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight (LBS/KG)
MODEL: MT 15B1-PTECHNICAL DATA
3-PHASE ISOLATING
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 97.48%
NEMA TP-1)
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0
PHYSICAL DIMENSIONS
MOUNTING: WALL
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Impedance
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
15
480
208Y / 120
220°C
150°C
170 / 78
Connection
(%z)
10KV
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
5.3
Dyn1(TT-1)
- Copper windings
861W
55W
45dB
![Page 9: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/9.jpg)
22
1
2
"
14
1
4
"
12
3
4
"
21"
22
1
2
"
18
3
4
"
FRONT VIEW SIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"
17
3
4
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 30A1TECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure NEMA 2
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
30
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG) 250 / 140
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
5.1
Open Delta auto
10KV
1250W
106W
45dB
- Copper windings
1
1
8
"
3
4
"1
1
8
"
3
4
"
Efficiency = 97.56%
( As per CSA C802.2 &
NEMA TP-1)
![Page 10: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/10.jpg)
22
1
2
"
14
1
4
"
12
3
4
"
21"
22
1
2
"
18
3
4
"
FRONT VIEW SIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"
17
3
4
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 30B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 97.56%
NEMA TP-1)
Primary connectors per phase : #14-#4
Secondary connectors per phase: #8-2/0
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
30
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)250 / 140
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
5.1
Dyn1(TT-1)
10KV
1664W
106W
45dB
- Copper windings
1
1
8
"
3
4
"1
1
8
"
3
4
"
![Page 11: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/11.jpg)
FRONT VIEWSIDE VIEW
25
1
2
"
27"
16
3
8
"
23"15
3
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"
19
7
8
"
1
1
4
"
1
2
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 45A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 97.98%
NEMA TP-1)
Primary connectors per phase : #14-#4
Secondary connectors per phase: #6-250MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
45
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG) 370 / 169
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.8
Dyn1(TT-1)
10KV
2000W
137W
45dB
- Copper windings
![Page 12: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/12.jpg)
FRONT VIEWSIDE VIEW
25
1
2
"
27"
16
3
8
"
23"15
3
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"
19
7
8
"
1
1
4
"
1
2
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 45B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 97.98%
NEMA TP-1)
Primary connectors per phase : #14-#4
Secondary connectors per phase: #6-250MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
45
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG) 370 / 169
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.8
Dyn1(TT-1)
10KV
2000W
137W
45dB
- Copper windings
![Page 13: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/13.jpg)
FRONT VIEWSIDE VIEW
25
1
2
"
27"
16
3
8
"
23"15
3
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"
19
7
8
"
1
1
4
"
1
2
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 50A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 97.98%
NEMA TP-1)
Primary connectors per phase : #14-#4
Secondary connectors per phase: #6-250MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
50
PHYSICAL DIMENSIONS
MOUNTING: WALL / FLOOR
600
208Y / 120
220°C
(LBS/KG)425 / 193
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.8
Dyn1(TT-1)
10KV
2080W
45dB
137W
- Copper windings
![Page 14: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/14.jpg)
FRONT VIEWSIDE VIEW
25
1
2
"
27"
16
3
8
"
23"15
3
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
Ø1"
19
7
8
"
1
1
4
"
1
2
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 50B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 97.98%
NEMA TP-1)
Primary connectors per phase : #14-#4
Secondary connectors per phase: #6-250MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
50
PHYSICAL DIMENSIONS
MOUNTING: WALL / FLOOR
480
208Y / 120
220°C
(LBS/KG)425 / 193
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.8
Dyn1(TT-1)
10KV
2080W
45dB
137W
- Copper windings
![Page 15: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/15.jpg)
FRONT VIEW SIDE VIEW
25
1
2
"
27"
16
3
8
"
23"15
3
8
"
MOUNTING HOLE Ø
3
4
"(TYP)
Ø1"
19
7
8
"
1
1
4
"
1
2
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 75A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.27%
NEMA TP-1)
Primary connectors per phase : #6-2/0
Secondary connectors per phase: #6-250MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
75
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG)520 / 237
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
4.7
Dyn1(TT-1)
10KV
2800W
50dB
200W
![Page 16: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/16.jpg)
FRONT VIEW SIDE VIEW
25
1
2
"
27"
16
3
8
"
23"15
3
8
"
MOUNTING HOLE Ø
3
4
"(TYP)
Ø1"
19
7
8
"
1
1
4
"
1
2
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 75B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.27%
NEMA TP-1)
Primary connectors per phase : #6-2/0
Secondary connectors per phase: #6-250MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
75
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)520 / 237
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
4.7
Dyn1(TT-1)
10KV
2800W
50dB
200W
![Page 17: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/17.jpg)
FRONT VIEW SIDE VIEW
30
3
8
"
20"
36
1
4
"
27
1
2
" 15
5
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
23
1
2
"
1
3
8
"2"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 112.5A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.35%
NEMA TP-1)
Primary connectors per phase : #8-250MCM
Secondary connectors per phase: #2/0-600MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
112.5
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG)820 / 375
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
3.8
Dyn1(TT-1)
10KV
- Copper windings
3438W
350W
50dB
1
3
8
"2"
![Page 18: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/18.jpg)
FRONT VIEW SIDE VIEW
30
3
8
"
20"
36
1
4
"
27
1
2
" 15
5
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
23
1
2
"
1
3
8
"2"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 112.5B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.35%
NEMA TP-1)
Primary connectors per phase : #8-250MCM
Secondary connectors per phase: #2/0-600MCM
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
112.5
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)820 / 375
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
3.8
Dyn1(TT-1)
10KV
- Copper windings
3438W
350W
50dB
1
3
8
"2"
![Page 19: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/19.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 150A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.53%
NEMA TP-1)
Primary connectors per phase : #4-250MCM
Secondary connectors per phase: #2/0-350MCM(D)
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
150
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG) 995 / 451
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.0
Dyn1(TT-1)
10KV
4042W
422W
50dB
- Copper windings
FRONT VIEW SIDE VIEW
30
3
8
"
20"
36
1
4
"
27
1
2
" 15
5
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
23
1
2
"
1
3
8
"2"
1
3
8
"2"
![Page 20: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/20.jpg)
FRONT VIEW SIDE VIEW
35" 24
1
2
"
46
3
4
"
28"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 225A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.55%
NEMA TP-1)
Primary connectors per phase : 2/0-350MCM
Secondary connectors per phase: 4/0-600MCM(D)
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
225
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG)1450 / 658
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
33"21
1
4
"
4.1
Dyn1(TT-1)
10KV
6058W
610W
55dB
- Copper windings
7
8
"
7
8
"
1
1
2
" 1
1
2
"
MOUNTING HOLE Ø
3
4
"
![Page 21: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/21.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 150B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.53%
NEMA TP-1)
Primary connectors per phase : #4-250MCM
Secondary connectors per phase: #2/0-350MCM(D)
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
150
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG) 995 / 451
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.0
Dyn1(TT-1)
10KV
4042W
422W
50dB
- Copper windings
FRONT VIEW SIDE VIEW
30
3
8
"
20"
36
1
4
"
27
1
2
" 15
5
8
"
MOUNTING HOLE
Ø
3
4
"(TYP)
23
1
2
"
1
3
8
"2"
1
3
8
"2"
![Page 22: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/22.jpg)
FRONT VIEW SIDE VIEW
35" 24
1
2
"
46
3
4
"
28"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 225B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.55%
NEMA TP-1)
Primary connectors per phase : 2/0-350MCM
Secondary connectors per phase: 4/0-600MCM(D)
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
225
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)1450 / 658
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
33"21
1
4
"
4.1
Dyn1(TT-1)
10KV
6058W
610W
55dB
- Copper windings
7
8
"
7
8
"
1
1
2
" 1
1
2
"
MOUNTING HOLE Ø
3
4
"
![Page 23: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/23.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 300A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.6%
NEMA TP-1)
Primary connectors per phase : 4/0-350MCM(S)
Secondary connectors per phase: 4/0-750MCM(D)
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
300
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG)1810 / 821
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.0
Dyn1(TT-1)
10KV
- Copper windings
7790W
790W
55dB
FRONT VIEW SIDE VIEW
35" 24
1
2
"
46
3
4
"
28"
33"21
1
4
"
7
8
"
7
8
"
1
1
2
" 1
1
2
"
MOUNTING HOLE Ø
3
4
"
![Page 24: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/24.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 300B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.6%
NEMA TP-1)
Primary connectors per phase : 4/0-350MCM(S)
Secondary connectors per phase: 4/0-750MCM(D)
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
300
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)1810 / 821
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
4.0
Dyn1(TT-1)
10KV
- Copper windings
7790W
790W
55dB
FRONT VIEW SIDE VIEW
35" 24
1
2
"
46
3
4
"
28"
33"21
1
4
"
7
8
"
7
8
"
1
1
2
" 1
1
2
"
MOUNTING HOLE Ø
3
4
"
![Page 25: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/25.jpg)
FRONT VIEWSIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
36
1
2
"30
3
4
"
51
5
8
"
34
1
4
"30
1
4
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 450A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.68%
NEMA TP-1)
Primary connectors per phase : N/A
Secondary connectors per phase: N/A
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
450
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG)2550 / 1157
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
Dyn1(TT-1)
10KV
4.3
10,100W
1100W
55dB
1"1"
1
8
"
1
8
"
36"
![Page 26: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/26.jpg)
FRONT VIEWSIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
36
1
2
"30
3
4
"
51
5
8
"
34
1
4
"30
1
4
"
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 450B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.68%
NEMA TP-1)
Primary connectors per phase : N/A
Secondary connectors per phase: N/A
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
450
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)2550 / 1157
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
Dyn1(TT-1)
10KV
4.3
10,100W
1100W
55dB
1"1"
1
8
"
1
8
"
36"
![Page 27: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/27.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 500A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.69%
NEMA TP-1)
Primary connectors per phase : N/A
Secondary connectors per phase: N/A
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
500
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG)2760 / 1252
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
Dyn1(TT-1)
10KV
4.1
10,220W
1200W
55dB
FRONT VIEWSIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
36
1
2
"30
3
4
"
51
5
8
"
34
1
4
"30
1
4
"
1"1"
1
8
"
1
8
"
36"
![Page 28: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/28.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 500B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.69%
NEMA TP-1)
Primary connectors per phase : N/A
Secondary connectors per phase: N/A
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
500
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)2760 / 1252
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
Dyn1(TT-1)
10KV
4.1
10,220W
1200W
55dB
FRONT VIEWSIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
36
1
2
"30
3
4
"
51
5
8
"
34
1
4
"30
1
4
"
1"1"
1
8
"
1
8
"
36"
![Page 29: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/29.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 600A1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.8%
NEMA TP-1)
Primary connectors per phase : N/A
Secondary connectors per phase: N/A
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
600
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
600
208Y / 120
220°C
(LBS/KG)3150 / 1429
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
4.1
Dyn1(TT-1)
10KV
10,300W
1280W
55dB
FRONT VIEWSIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
36
1
2
"30
3
4
"
51
5
8
"
34
1
4
"30
1
4
"
1"1"
1
8
"
1
8
"
36
![Page 30: MARCUS · Enclosure Drip shield KVA Primary (Volts) Secondary (Volts) Phase 3](https://reader031.fdocuments.in/reader031/viewer/2022022109/5c06c10a09d3f2987a8c5701/html5/thumbnails/30.jpg)
KVA
Primary (Volts)
Secondary (Volts)
Phase 3
Temperature Rise
Insulation Class
Frequency 60Hz
DESCRIPTION
Type DRY TYPE DISTRIBUTION (ANN)
Weight
MODEL:MT 600B1-PTECHNICAL DATA
MARCUS
3-PHASE ISOLATING
Marcus Transformer LTD
Phone: 1-800-267-7376
Fax: 1-866-205-7526
Email: [email protected]
Enclosure Drip shield
PERFORMANCE
No load loss
Total loss
Noise level
EFFICIENCY
Efficiency = 98.8%
NEMA TP-1)
Primary connectors per phase : N/A
Secondary connectors per phase: N/A
Customer / PO
COMMENTS
Project
Engineer
Revision Date
Connection
Impedance (%z)
Contractor
BIL.
FEATURES:
- Anti-vibration pads installed between the core/coil and
the enclosure
- Ground lug provided
- Leads brought-up and solidly positioned into separate
terminal boards
- Transformer meets the efficiency values as per CSA
C802.2 / NEMA TP-1
(As per CSA C802.2 &
600
PHYSICAL DIMENSIONS
MOUNTING: FLOOR
480
208Y / 120
220°C
(LBS/KG)3150 / 1429
150°C
- CSA enclosure: ventilated painted ASA 61gray
- Copper ground strap between core/coil and enclosure
- CSA certified / UL listed
- Copper windings
4.1
Dyn1(TT-1)
10KV
10,300W
1280W
55dB
FRONT VIEWSIDE VIEW
MOUNTING HOLE
Ø
3
4
"(TYP)
36
1
2
"30
3
4
"
51
5
8
"
34
1
4
"30
1
4
"
1"1"
1
8
"
1
8
"
36