Post on 09-Oct-2020
Z-MAX 45 Termination Instructions
1A
Tools
1B 1C Remove center spline
Flush Cutters
JacketStripper
ZMAX45Termination tool(p/n: Z-TOOL-45)
!
F/UTP shown here
See back page for othercable types.
Drain wire& foil
InvertFoil
WrapDrainwire
RemoveMylar Wrap
2
RemoveJacket
~ 2.5 in. (64 mm)
3
UTP (skip to step 1C)
TerminationModule Outlet Body
Hybrid Version
Rearcover
Zip Tie
FlatScrewdriver
Outlet BodyKeystone Version
Mount lacing module in toolhandle facing front
Optional:For large O.D.cables, pliersmay be helpfulwhen lacing
Back
Front
OR
Cable Jacketstop
Lace all four pairswith lacing modulesupported in toolhandle.Pin#s:
1 2 3 6 5 4 7 8
Z-MAX 45 Termination Instructions
4
87
10
FlushCuttersonly
OR
Ensure outlet is fully seatedonto base of tool duringtermination.
!
Front view
Remove
1
Cut flush
2
5
+90◦
6
Keying features for properorientation
9
1
2
3
-90◦
OR
OR
Drain wireTie-wrap
12
Z-MAX 45 Termination Instructions
13
14
12
1
2
Tip: Squeeze outletagainst lip on toolto secure whenpulling apart
Pull apart by hand or use tool
1
1
2
11
Faceplate mountfrom rear asshown:
Faceplate Mounting:
3
Disassembly:
©2
01
8S
iem
on
Re
v.B
12
/18
10
0.2
5197
.00
To assist safe installations, comply with the following:A. Use caution when installing or modifying telecommunications circuits.B. Never touch uninsulated wire terminals unless the circuit has been disconnected.C. Never install this device in a wet location.D. Never install wiring during a lightning storm.
Lors de l'installation, respectez les consignes de sécurité suivantes:A. Utiliser avec prudence lors de l'installation ou de la modification circuits detélécommunications.B. Ne jamais toucher les bornes de fil métallique non isolés sauf si le circuit a été débranché.C. Ne jamais installer cet appareil dans un endroit humide.D. Ne jamais installer pendant un orage.
To ensure you have the latestrevision to this document, please visit:
Z-MAX 45 Termination – Alternate Cable types
S/FTPStranded(26 AWG)
Co
ntin
ue
To
Ste
p2
!
4X (Foil)1A 1B 1C 1D 1E
~38 mm(1.5 in)
~13 mm(0.5 in)
~13 mm(0.5 in)
Co
ntin
ue
To
Ste
p2
!
U/FTPSolid
1A 1B
~70 mm(2.75 in)
≤ 6.35 mm(.25 in)
1X(foil)
DrainWire
3X
(foil)
360°2X
*Note for OSP Category 6A shielded cable w/double jacket:Please refer to the supplemental cable preparation instructionsavailable at: www.siemon.com/us/download/installation.aspxand click on WORK AREA.
www.siemon.com
S/FTPandF/FTPSolid(23 AWG)
Co
ntin
ue
To
Ste
p2
!
1A 1B 1C
~64 mm(2.5 in)
F/FTP & S/FTP
F/FTP S/FTP
6.35 mm(.25 in)
6.35 mm(.25 in)
4X(Foil)
F/FTP & S/FTP
S/FTPSolid(22 AWG)
4X (Foil)
~51 mm(2 in)
1A 1B 1C 1D
360°
Note braidwrap direction
Co
ntin
ue
To
Ste
p2
!
~10-12 mm(.4-.5 in)
~13 mm(~.5 in)
~13 mm(~.5 in)
~13 mm(~.5 in)