Working safely above the foramen

Post on 28-Mar-2016

222 views 1 download

Tags:

description

48 year old female with failed abutment molar. Molar removed and site grafted. Mandibular canal and foramen are visible on simple PA radiograph. 8 mm implants should just work. Precise depth drilling with confirmation at reduced drill depth allow secure operation above critical structures. No need for CBCT. At placement additional grafting allow for increase of keratinized tissues.

Transcript of Working safely above the foramen

Copyright © 2012 Idondivi, Inc. All rights reserved.

Categories ; Posterior, Grafting, Multiple implants, Blue Sky Bio

2 Copyright © 2012 Idondivi, Inc. All rights reserved

Failing abutment molar

3 Copyright © 2012 Idondivi, Inc. All rights reserved

Failing abutment molar

4 Copyright © 2012 Idondivi, Inc. All rights reserved

Extraction, non resorbable PTFE membrane

5 Copyright © 2012 Idondivi, Inc. All rights reserved

At 3 weeks

6 Copyright © 2012 Idondivi, Inc. All rights reserved

At 3 weeks

7 Copyright © 2012 Idondivi, Inc. All rights reserved

At 3 months post extraction, cast based planning

8 Copyright © 2012 Idondivi, Inc. All rights reserved

Screw retained crown setup

9 Copyright © 2012 Idondivi, Inc. All rights reserved

Perfect but tight fit for two 4 mm impants

10 Copyright © 2012 Idondivi, Inc. All rights reserved

Cross bars removed

11 Copyright © 2012 Idondivi, Inc. All rights reserved

Two 8 mm implants planned. Note close proximation to mental foramen on X ray

12 Copyright © 2012 Idondivi, Inc. All rights reserved

No need for rotational adjustment, so use green 0 degree rotation blocks

13 Copyright © 2012 Idondivi, Inc. All rights reserved

Flapped access allowing for grafting hard and soft tissue

14 Copyright © 2012 Idondivi, Inc. All rights reserved

18.7 mm drill shortened with green flexistop to evaluate distance to foramen

15 Copyright © 2012 Idondivi, Inc. All rights reserved

Length pins used to evaluate that indeed an 8 mm implant is OK, prep not yet to

full length

16 Copyright © 2012 Idondivi, Inc. All rights reserved

Additional 1.5 mm OK to prep deeper at # 29 implant above foramen. Check

twice drill once

17 Copyright © 2012 Idondivi, Inc. All rights reserved

Prep now to full length

18 Copyright © 2012 Idondivi, Inc. All rights reserved

Nobel Biocare starter drill used to flatten top of ridge.

19 Copyright © 2012 Idondivi, Inc. All rights reserved

3.2 mm Astra facilitate drill

20 Copyright © 2012 Idondivi, Inc. All rights reserved

3.7 MM Astra facilitate drill reduced length with 3 mm flexistop for stepped back

preparation. 18 – 3 – 10 = 5 mm

21 Copyright © 2012 Idondivi, Inc. All rights reserved

Confirmation

22 Copyright © 2012 Idondivi, Inc. All rights reserved

Gentamycin antibiotic eyedrops

23 Copyright © 2012 Idondivi, Inc. All rights reserved

Blue Sky Bio Conus implant 8 x 4 mm. Carrier set for guided depth control

24 Copyright © 2012 Idondivi, Inc. All rights reserved

Implants placed as planned, note local buccal tread exposed on # 29 implant

25 Copyright © 2012 Idondivi, Inc. All rights reserved

Bone chip harvest

26 Copyright © 2012 Idondivi, Inc. All rights reserved

Bone chip placed

27 Copyright © 2012 Idondivi, Inc. All rights reserved

Protected with non resorbing bio-oss

28 Copyright © 2012 Idondivi, Inc. All rights reserved

Mucograft to increase keratinized tissue

29 Copyright © 2012 Idondivi, Inc. All rights reserved

Implants placed as planned

30 Copyright © 2012 Idondivi, Inc. All rights reserved

Implants placed as planned

31 Copyright © 2012 Idondivi, Inc. All rights reserved

3 weeks post placement, note increase in buccal attached tissues