Transcript of Updates for B&W Tek’s Mobile Molecular Spectroscopy September 24, 2013 B&W Tek, Inc Copyright 2013...
- Slide 1
- Updates for B&W Teks Mobile Molecular Spectroscopy
September 24, 2013 B&W Tek, Inc Copyright 2013 B&W Tek,
Inc.www.bwtek.com1
- Slide 2
- Whats New New software release for NanoRam NOS/NID 4.20 Updated
Manual Release Notes Installation and Upgrade instructions
Additional Application Support Documents for NanoRam Copyright 2013
B&W Tek, Inc.www.bwtek.com2
- Slide 3
- NanoRam Software Highlights ver 4.20 Library transfer available
for user-defined libraries Export of NanoRam results reports for
integration with LIMS Removed Device Manager function in NOS
simplify number of logins Update User interface for NanoRam
single/batch Identification testing Remove Archive/Retrieve from
NID- possibility of too many copies of data on PC Full details in
Release Notes available along with software and updated manual from
Distributor portal; Copyright 2013 B&W Tek,
Inc.www.bwtek.com3
- Slide 4
- Library Transfer Synchronize library to NOS After
synchronization libraries are resident in NID Software Choose
samples of library to transfer (can only transfer user-defined
libraries) Connect destination NanoRam to NID Transfer selected
sample spectra to another NanoRam Unit Copyright 2013 B&W Tek,
Inc.www.bwtek.com4
- Slide 5
- Copyright 2013 B&W Tek, Inc.www.bwtek.com5 1. Select
Library 2. Select Sample Spectra 3. Transfer to a connected
unit
- Slide 6
- Copyright 2013 B&W Tek, Inc.www.bwtek.com6
- Slide 7
- Library Transfer Screen in NID Copyright 2013 B&W Tek,
Inc.www.bwtek.com7 Transferred library name prefixed with T Must
synchronize from ->Device->Sync to complete the Library
transfer process
- Slide 8
- Audit Trail after Synchronize NanoRam Copyright 2013 B&W
Tek, Inc.www.bwtek.com8
- Slide 9
- Information on Transfer included as Note with Library Spectrum
Copyright 2013 B&W Tek, Inc.www.bwtek.com9
- Slide 10
- LIMS Export At time of synchronizing NanoRam unit with NID All
csv files sent to folder: ProgramLocation\BWTEK\NID\DataBase\NID
Report Copyright 2013 B&W Tek, Inc.www.bwtek.com10
- Slide 11
- LIMS Export at later time Copyright 2013 B&W Tek,
Inc.www.bwtek.com11
- Slide 12
- Example csv file from LIMS Export Copyright 2013 B&W Tek,
Inc.www.bwtek.com12 First line indicates report type All the
information that is included in pdf reports is included in the csv
file
- Slide 13
- Updated Functions for ADMIN user Create calibration file
(factory-set Polystyrene file can no longer be overwritten) Set
system clock Set password expiration Define sample information
fields Copyright 2013 B&W Tek, Inc.www.bwtek.com13
- Slide 14
- Setting of User-defined Fields Sample information fields now
include 2 required: Run Name and Product Name and three optional
user-defined fields Only the 2 required and any UDF will appear in
testing interface Copyright 2013 B&W Tek, Inc.www.bwtek.com14
Customizable fields (by ADMIN user)
- Slide 15
- Updated Identification Mode Interface Removed terminology for
Single Mode/Batch Mode Now define how many samples in a run; if =
1, this is the single mode When # of samples in run > 1, must
enter Run Name Copyright 2013 B&W Tek, Inc.www.bwtek.com15
- Slide 16
- Multiple Samples in Run Define number of samples in Run
(formerly Batch Mode) If a sample fails, user is asked if wants to
run another sample: must enter Note if chooses Yes Continue Run
until reach end Can Pause the Run, and return to it at a later time
Copyright 2013 B&W Tek, Inc.www.bwtek.com16
- Slide 17
- Documentation and Services User Manuals Quick Start Manual for
Operator-level users DQ/IQ/OQ/PQ Software release notes
Identification Method Development Guidelines for the NanoRam Method
Validation Report SOP for Operation of NanoRam IQ/OQ implementation
and user training Method Development and Validation On-site Support
Customized On-site training Copyright 2013 B&W Tek,
Inc.www.bwtek.com17
- Slide 18
- THANK YOU ! www.bwtek.com18 Dr. Katherine A. Bakeev B&W Tek
Inc. 19 Shea Way Newark, DE 19713, USA support@bwtek.com Copyright
2013 B&W Tek, Inc.
- Slide 19
- Updates to Raman Price List Added prices for ST Japan Spectral
Libraries Performance testing kit for iRaman instruments included
with IQ/OQ and as standalone offering Copyright 2013 B&W Tek,
Inc.www.bwtek.com19 Part NumberModel NumberDescription
810000710BAC151BVideo microscope sampling system for use with
B&W Tek's lab and industrial Raman probes. Dual wavelength
available for 532, 785 or 1064nm laser excitation. 840000287NR-LVH
Liquid vial holder adaptor for use with the BAC100 Lab Grade Raman
Probe with shaft diameter of 9.5 mm. Compatible with 15mm- diameter
vial. 6-pack of 15mm borosilicate glass vials included
810000738RSK001 Raman Sample Kit for BWTek Raman systems. Kit
includes:Pouch for samples, Powder Cellulose, Powder Methocel MC,
Powder Calcium carbonate, Powder Potassium carbonate, Liquid
Glycerin, Liquid Ethanol, Liquid Methanol, Tablet Tylenol, Tablet
Aspirin,. User instructions
- Slide 20
- Upcoming IQ/OQ certification October 8-10, 2013 at the B&W
Tek corporate headquarters in Newark, DE, USA The third day is
focusing on the training for our portable Raman systems, including
the i-Raman Plus and i-Raman EX. November 6-7, 2013 in Hamburg,
Germany Copyright 2013 B&W Tek, Inc.www.bwtek.com20