Post on 26-Jun-2020
DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE
©
OW
NE
R: J
AY
L. B
AIR
PH
ON
E: (
435)
770-
8636
EM
AIL
: jay
@ba
irdes
igns
.com
WE
B: b
aird
esig
ns.c
om33
6 S
UN
BU
RS
T LN
.R
ICH
MO
ND
, UT,
843
33
2/14/2019
TIT
LE:
NE
IGH
BO
RH
OO
D N
ON
-PR
OF
ITH
OU
SIN
G C
OR
PO
RA
TIO
NC
OV
ER
PA
GE
THE ASPENNEIGHBORHOOD NON-PROFIT HOUSING CORPORATION
CONTENTS:1. COVER PAGE2. FOUNDATION / BASEMENT FLOOR PLAN3. MAIN FLOOR PLAN4. ELEVATIONS5. FRAMING PLANS & DETAILS6. ELECTRICAL PLANS
PR
OJE
CT
FO
R:
PAGE #
1
DATE:
S
S
S
S
SS
WH
3068
4040LS
4040LS 4040LS 4040LS
4068
2868
4068
2868
4068
2868
2868
3068
2468
2868
5068
4068
2868
UP
A5
A5
A5
A5
5'-4"6'-4" 6'-3"17'-7"
5'-9 1/2" 5'-7"
4'-2 1/4"
6'-8
1/4
"
12'-0 1/2" 12'-1"
24'-1 1/2" 20'-6" 11'-4 1/2"
56'
13'-2
"3
1/2"
8'-4
"3
1/2"
2'-1
" 3 1/
2"11
'-10"
36'-3
1/2
"
1'
6'-1"5'-1"
11'-2"3 1/2"
6'-1"3 1/2"
23'-10"3 1/2"
2'-1"3 1/2"
11'-8"
56'
18'
5'-9
1/2
"
11'-1
0"8"
23'-9
1/2
"
36'-3
1/2
"
1'
3'-5
"3'
3 1/
2"4'
-5 1
/2"
13'-5
1/4
"
3 1/
2"
3'-5
"3
1/2"
7'-9
"3
1/2"
3'-8
"
9'-2
"5
1/2"
3'-1
1"3
1/2"
3'-3
3/4
"3
1/2"
11'-8
1/2
"
5'-5"1'-5"
3 1/2"3'-4"
3 1/2"8'-1"
3 1/2"2'-1"
3 1/2"3'-5" 3 1/2"
4 1/2"
3 1/2"5'-4"
3'-9"3 1/2"
6'-5 1/2"
22'-10" x 23'-2"
23'-9" x 13'
20'-6" x 4'-2"
9'-4" x 12'-1"
6'-5" x 11'-4"8' x 11'-4"
2' x 6'
10'-7" x 10'-5"
2' x 6'-3"
6'-1" x 2'
2' x 4'-8"
5'-7" x 8'-3"
10'-1" x 10'-9"
6' x 8'-9"
6' x 3'-10"
Unexcavated Garage
Bedroom #6
Cold Storage
Closet
Bedroom #4
Laundry
Storage
Closet
Bath
Closet
Bedroom #5
Craft / Office
Living
Mech.
2x6 WALL
Closet
GENERAL NOTES:1. ALL CONSTRUCTION AND DETAILSSHALL COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE AND STATE AND LOCAL CODES.2.CONTRACTOR SHALL BERESPONSIBLE FOR THE ACCURATEPLACEMENT OF THE BUILDING ONTHE SITE. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELDBEFORE ANY WORK PROCEEDS.3. GAS/PROPANE FORCED AIRHEAT THRU-OUT. SUBCONTRACTOR TO SUPPLY GENERAL CONTRACTORWITH COMPLETE SHOP DRAWINGSAND HEAT LOSS CALCULATIONS.ALL WARM AIR DUCTS AND COLDAIR RETURNS SHOWN ARE FOR REFERENCE ONLY.4. FLOOR JOISTS ARE TO BE AS PER FRAMING PLAN OR COMPATIBLE.FLOOR DEFLECTION MUST BEL/480 OR BETTER.5. CONTRACTOR SHALL VERIFYAND BE RESPONSIBLE FORALL CONSTRUCTION DETAILS.6. 5/8" TYPE "X" SHEET ROCK AT GARAGEWALLS CEILING AND BEARING WALLSCOMMON TO HOUSE. INSULATE HOUSE WALLS.7. WIRE FOR TELEPHONE AND TELEVISIONJACKS (UL LISTED) GENERAL CONTRACTORTO COORDINATE LOCATIONS WITH OWNER.ALL ELECTRICAL PARTS SHOWN ARE FOR REFERENCE ONLY. CHECK WITH OWNER FOREXACT LOCATION.8. CONTRACTOR SHALL VERIFY ALL BEAMAND JOISTS SIZES AND SPACING.9. GENERAL CONTRACTOR TO VERIFY WITHOWNER ON ALL EXTERIOR DOOR AND WINDOW TYPES AND MANUFACTURER PRIORTO THE STARTING OF ANY FRAMING.10. SEE FOUNDATION PLAN FOR LOCATIONSOF FOUNDATION STRAPS.11. ALL HEADERS & BEAMS ARE TO BE 2X10DF #2 BTR UNLESS NOTED OTHER WISE.12. ALL WINDOWS TO BE DOUBLE PANELOW-E GRADE13. ALL EXTERIOR BASEMENT WALLS TO HAVEA MINIMUM OF R-11 INSULATIONS14. ALL EXTERIOR ABOVE GRADE WALLS TOHAVE A MINIMUM OF R-21 INSULATION UNLESSNOTED OTHER WISE.15. ALL ATTIC SPACES TO HAVE A MINIMUMOF R-50 INSULATION UNLESS NOTED OTHER16. ALL DOORS SEPARATING GARAGE FROMLIVING SPACE AND FURNACE ROOM TO MEETOR EXCEED CODE R302.5.1. (20-MINUTE FIRE-RATED DOORS, EQUIPPED WITH A SELF-CLOSING DEVICE.)17. COMBUSTION AIR FOR FURNACE ANDWATER HEATERS TO MEET OR EXCEED G240718. CLOTHES DRYER EXHAUST VENTS TOMEET OR EXCEED M1502 (VENTING CANNOTPENETRATE FIRE RATED CONSTRUCTIONMATERIALS).19. ARC FAULT PROTECTION TO BE PROVIDEDAS PER 3802.12, AND BE COMBINATION TYPE.20. TAMPER RESISTANT OUTLETS ARE TO BEINSTALLED THROUGHOUT THE ENTIREPROJECT.21. EXTERIOR OUTLETS WILL BE REQUIRED TOHAVE COVERS OVER THEM TO CONFORMWITH SECTION E3902.8 THROUGH E3902.10
GUARDRAIL NOTES:1. 36" (MIN) HIGH GUARDRAILS AREREQUIRED FOR UNENCLOSED FLOORAND ROOF OPENINGS, OPEN ANDGLAZED SIDES OF STAIRWAYS,LANDINGS, DECKS, RAMPS, ANDPORCHES, WHICH ARE MORE THAN 30INCHES ABOVE GRADE OR A FLOOR OROTHER SURFACE BELOW.2. OPEN GUARDRAILS SHALL HAVEINTERMEDIATE RAIL SPACING ORPATTERN SUCH THAT A 4-INCH SPHERECANNOT PASS THROUGH AND THETRIANGULAR AREA FORMED BY TREAD,RISER AND GUARDRAIL SO THAT A 4-INCH SPHERE CANNOT PASS THR0UGH.3. HAND RAIL REQUIRED WHEN (40 ORMORE RISERS ARE USED PER IRC311.7.8
DN
CONC. PATIO12' x 12'
(2) 2X4 W
ALLS
FO
R F
LUE
CH
AS
E
SYMBOLS:
HEAT VENT
WATER FAUCETW
FLOOR DRAIN
BEARING WALLS2" X 4" BOTTOM PLATE
INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE
DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE
©
OW
NE
R: J
AY
L. B
AIR
PH
ON
E: (
435)
770-
8636
EM
AIL
: jay
@ba
irdes
igns
.com
WE
B: b
aird
esig
ns.c
om33
6 S
UN
BU
RS
T LN
.R
ICH
MO
ND
, UT,
843
33
2/14/2019
TIT
LE:
NE
IGH
BO
RH
OO
D N
ON
-PR
OF
ITH
OU
SIN
G C
OR
PO
RA
TIO
N
PR
OJE
CT
FO
R:
PAGE #
2
1432 SQ.FT. UNFINISHED BASEMENTFOUNDATION & BASEMENT FLOOR PLAN
SCALE: 1/4" = 1'
FO
UN
DA
TIO
N &
BA
SE
ME
NT
FLO
OR
PLA
N
DOORS ARE TO BE CENTERED IN HALLWAYS & CLOSETS.DOORS NOT CENTERED WILL BE 5" (ROUGH OPENING EDGE)
FROM NEAREST WALL AND 9" FROM NEAREST FOUNDATION WALL.
DATE:
GENERAL NOTES:1. ALL CONSTRUCTION AND DETAILSSHALL COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE AND STATE AND LOCAL CODES.2.CONTRACTOR SHALL BERESPONSIBLE FOR THE ACCURATEPLACEMENT OF THE BUILDING ONTHE SITE. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELDBEFORE ANY WORK PROCEEDS.3. GAS/PROPANE FORCED AIRHEAT THRU-OUT. SUBCONTRACTOR TO SUPPLY GENERAL CONTRACTORWITH COMPLETE SHOP DRAWINGSAND HEAT LOSS CALCULATIONS.ALL WARM AIR DUCTS AND COLDAIR RETURNS SHOWN ARE FOR REFERENCE ONLY.4. FLOOR JOISTS ARE TO BE AS PER FRAMING PLAN OR COMPATIBLE.FLOOR DEFLECTION MUST BEL/480 OR BETTER.5. CONTRACTOR SHALL VERIFYAND BE RESPONSIBLE FORALL CONSTRUCTION DETAILS.6. 5/8" TYPE "X" SHEET ROCK AT GARAGEWALLS CEILING AND BEARING WALLSCOMMON TO HOUSE. INSULATE HOUSE WALLS.7. WIRE FOR TELEPHONE AND TELEVISIONJACKS (UL LISTED) GENERAL CONTRACTORTO COORDINATE LOCATIONS WITH OWNER.ALL ELECTRICAL PARTS SHOWN ARE FOR REFERENCE ONLY. CHECK WITH OWNER FOREXACT LOCATION.8. CONTRACTOR SHALL VERIFY ALL BEAMAND JOISTS SIZES AND SPACING.9. GENERAL CONTRACTOR TO VERIFY WITHOWNER ON ALL EXTERIOR DOOR AND WINDOW TYPES AND MANUFACTURER PRIORTO THE STARTING OF ANY FRAMING.10. SEE FOUNDATION PLAN FOR LOCATIONSOF FOUNDATION STRAPS.11. ALL HEADERS & BEAMS ARE TO BE 2X10DF #2 BTR UNLESS NOTED OTHER WISE.12. ALL WINDOWS TO BE DOUBLE PANELOW-E GRADE13. ALL EXTERIOR BASEMENT WALLS TO HAVEA MINIMUM OF R-11 INSULATIONS14. ALL EXTERIOR ABOVE GRADE WALLS TOHAVE A MINIMUM OF R-21 INSULATION UNLESSNOTED OTHER WISE.15. ALL ATTIC SPACES TO HAVE A MINIMUMOF R-50 INSULATION UNLESS NOTED OTHER16. ALL DOORS SEPARATING GARAGE FROMLIVING SPACE AND FURNACE ROOM TO MEETOR EXCEED CODE R302.5.1. (20-MINUTE FIRE-RATED DOORS, EQUIPPED WITH A SELF-CLOSING DEVICE.)17. COMBUSTION AIR FOR FURNACE ANDWATER HEATERS TO MEET OR EXCEED G240718. CLOTHES DRYER EXHAUST VENTS TOMEET OR EXCEED M1502 (VENTING CANNOTPENETRATE FIRE RATED CONSTRUCTIONMATERIALS).19. ARC FAULT PROTECTION TO BE PROVIDEDAS PER 3802.12, AND BE COMBINATION TYPE.20. TAMPER RESISTANT OUTLETS ARE TO BEINSTALLED THROUGHOUT THE ENTIREPROJECT.21. EXTERIOR OUTLETS WILL BE REQUIRED TOHAVE COVERS OVER THEM TO CONFORMWITH SECTION E3902.8 THROUGH E3902.10
GUARDRAIL NOTES:1. 36" (MIN) HIGH GUARDRAILS AREREQUIRED FOR UNENCLOSED FLOORAND ROOF OPENINGS, OPEN ANDGLAZED SIDES OF STAIRWAYS,LANDINGS, DECKS, RAMPS, ANDPORCHES, WHICH ARE MORE THAN 30INCHES ABOVE GRADE OR A FLOOR OROTHER SURFACE BELOW.2. OPEN GUARDRAILS SHALL HAVEINTERMEDIATE RAIL SPACING ORPATTERN SUCH THAT A 4-INCH SPHERECANNOT PASS THROUGH AND THETRIANGULAR AREA FORMED BY TREAD,RISER AND GUARDRAIL SO THAT A 4-INCH SPHERE CANNOT PASS THR0UGH.3. HAND RAIL REQUIRED WHEN (40 ORMORE RISERS ARE USED PER IRC311.7.8
DN
CONC. PATIO12' x 12'
(2) 2X4 W
ALLS
FO
R F
LUE
CH
AS
E
SYMBOLS:
HEAT VENT
WATER FAUCETW
FLOOR DRAIN
BEARING WALLS2" X 4" BOTTOM PLATE
INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE
DN
D/W
REF.
16080
5040LS2630FX3068
5040LS
2228
LS
2868
40682868
2468
4068
3068
2868
2468
3068
2468
3630LS
6068
5050LS 5040LS
2068
3868
2668
DNA
TT
ICA
CC
ES
S 2
2"X
30"
A5
A5
A5
A5
6'-7"12'14'-6"4'-11 1/2"5 1/2"
5'-1" 4'-11"5 1/2"
5'-1" 5'-1"5 1/2"
2'-2"
2'-2
"
3'-0 1/16"
2'-5
"
3 1/2"11'-8 1/2" 11'-6 1/2"
3 1/2"2'-4" 6'-4 1/2" 2'
23'-10" 10'-8 1/2"3 1/2"
10'5 1/2"
10'-2"5 1/2"
55'-11"
18'
5'-3
"3
1/2"
5 1/
2"7'
-3"
3 1/
2"4'
5 1/
2"23
'-3"
3 1/
2"
36'
6'
3'-1
0"4'
-7"
5 1/
2"10
'-1"
3 1/
2"2'
-1" 3
1/2"
8'-5
"3
1/2"
13'-7
1/2
"5
1/2"
36'
6'
5 1/2"5'-6"5'-7"
5 1/2"11'-1"
3 1/2"5'
7"38'-0 1/2"
5 1/2"55'-11"
4'-2"3 1/2"
8'-4"3 1/2"
2'-6" 7'-8"
6'-11"3 1/2"
3'-4" 3 1/2" 4'-7"3 1/2"
5'-3 1/2"3 1/2"
3'-5"3 1/2"
6'-5 1/2"
3'-5"3 1/2"
1'-2"
3 1/2"5'
2'-1
"3
1/2"
9'-1
"
5'-2
"3'
-2"
3 1/
2"5'
3 1/
2"3'
-5"
3 1/
2"7'
-1"
3 1/
2"4'
-1"
5 1/
2"5'
-6 1
/2"
17'-4
"3
1/2"
2'-1
"3
1/2"
5'-8
"3'
-5"
135°
135°
20'-6" x 5'-1"
4'-6" x 2'
14'-5" x 17'-3"
1'-1" x 4'-7"
6'-5" x 8'-4"
4'-11" x 2'
23'-2" x 23'-2"
11' x 13'-7"
10'-1" x 10'
12'-10" x 11'-6"
5' x 9'
4'-11" x 8'-3"
10'-1" x 11'-5"
10'-8" x 11'-6"
3'-11" x 3'-11"
4'-11" x 4'-11"
7'-3" x 11'-9"
3'-3" x 2'
Stairwell
Garage
Bedroom #3
Linen
FamilyMaster Bdrm
Pantry
W.I.C.
Closet
Closet
Bedroom #2
Closet
Porch
Kitchen
Entry
Dining
Bath
MasterBath
CONC. PATIO12' x 12'
(2) 2X4 W
ALLS
FO
R F
LUE
CH
AS
E
W
W
DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE
©
OW
NE
R: J
AY
L. B
AIR
PH
ON
E: (
435)
770-
8636
EM
AIL
: jay
@ba
irdes
igns
.com
WE
B: b
aird
esig
ns.c
om33
6 S
UN
BU
RS
T LN
.R
ICH
MO
ND
, UT,
843
33
2/14/2019
TIT
LE:
NE
IGH
BO
RH
OO
D N
ON
-PR
OF
ITH
OU
SIN
G C
OR
PO
RA
TIO
N
PR
OJE
CT
FO
R:
PAGE #
3
1321 SQ.FT.MAIN FLOOR PLAN
SCALE: 1/4' = 1'
MA
IN F
LOO
R P
LAN
DOORS ARE TO BE CENTERED IN HALLWAYS & CLOSETS.DOORS NOT CENTERED WILL BE 5" (ROUGH OPENING EDGE)
FROM NEAREST WALL AND 9" FROM NEAREST FOUNDATION WALL.
DATE:
6126
12
6123
12
18" O.H. TYP.
ALUMINUM SOFFIT& FASCIA TYP.
3-1/2" CORNERBOARD TYP.
3-1/2" TRIM BOARD TYP.
CULTURED STONE
VINYL SIDING
VINYL VERTICAL SIDING
CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE
PROPOSED GRADEVINYL RAILING
VINYL VERTICAL SIDING
VINYL SIDING
MIN. 30 YEAR ASPHALT SHINGLES
BOTTOM OF FOOTINGS TO BE AMIN. OF 30" BELOW FINISHED GRADE
INSTALL EGRESS WINDOW WELL& WINDOW WELL COVER
(NOT SHOWN)
VINYL SIDING
18" O.H. TYP.
3-1/2" CORNERBOARD TYP.
3-1/2" TRIM BOARD TYP.
CULTUREDSTONE
612
312
612
CONC. STEPS
CONC. DRIVEWAY
18" O.H. TYP.
ALUMINUM SOFFIT& FASCIA TYP.
3-1/2" CORNERBOARD TYP.
CONC. SIDEWALK
VINYL SIDING
CULTURED STONE
CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE
PROPOSED GRADE
MIN. 30 YEAR ASPHALT SHINGLES
BOTTOM OF FOOTINGS TO BE AMIN. OF 30" BELOW FINISHED GRADE
18" O.H. TYP.
3-1/2" CORNERBOARD TYP.
12'x12" CONC. PATIO
612
INSTALL EGRESS WINDOW WELL& WINDOW WELL COVER
(NOT SHOWN)
18" O.H. TYP.
INSTALL EGRESS WINDOW WELL& WINDOW WELL COVER
(NOT SHOWN)
12'x12" CONC. PATIO
3-1/2" CORNERBOARD TYP.
ALUMINUM SOFFIT& FASCIA TYP.
CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE
PROPOSED GRADE
VINYL SIDING
MIN. 30 YEAR ASPHALT SHINGLES
VINYL SIDING
612
612
612
312
CONC. STEPS
CONC. DRIVEWAY
18" O.H. TYP.
ALUMINUM SOFFIT& FASCIA TYP.
3-1/2" CORNERBOARD TYP.
VINYL SIDING
CULTURED STONE
CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE
PROPOSED GRADE
MIN. 30 YEAR ASPHALT SHINGLES
18" O.H. TYP.
3-1/2" CORNERBOARD TYP.
12'x12" CONC. PATIO
DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE
©
OW
NE
R: J
AY
L. B
AIR
PH
ON
E: (
435)
770-
8636
EM
AIL
: jay
@ba
irdes
igns
.com
WE
B: b
aird
esig
ns.c
om33
6 S
UN
BU
RS
T LN
.R
ICH
MO
ND
, UT,
843
33
2/14/2019
TIT
LE:
NE
IGH
BO
RH
OO
D N
ON
-PR
OF
ITH
OU
SIN
G C
OR
PO
RA
TIO
N
PR
OJE
CT
FO
R:
PAGE #
4
FRONT ELEVATIONSCALE: 1/4" = 1'
LEFT ELEVATIONSCALE: 1/4" = 1'
REAR ELEVATIONSCALE: 1/4" = 1'
RIGHT ELEVATIONSCALE: 1/4" = 1'
ELE
VA
TIO
NS
DATE:
S
S
S
S
SS
WH
3068
4040LS
4040LS 4040LS 4040LS
4068
2868
4068
2868
4068
2868
2868
3068
2468
2868
5068
4068
2868
UP
2x6 WALL
FLOOR JOISTS @ 16" O.C.
SPECIFIED BY OTHERS
DN
REF.
16080
5040LS2630FX3068
5040LS
2228
LS
2868
40682868
2468
4068
3068
2868
2468
3068
2468
3630LS
6068
5050LS 5040LS
2068
3868
2668
DN
AT
TIC
AC
CE
SS
22"
X30
"
CONC. PATIO12' x 12'
(2) 2X4 W
ALLS
FO
R F
LUE
CH
AS
E
W
W
ENGINEERED TRUSSES @ 24" O.C.
SPECIFIED BY OTHERS
LOCATION OF FALSE DORMER
T
126
T
2x TREATED MUDSILL
SILL SEALER
CONCRETE FOUNDATION8" MIN. THICKNESS
HORIZONTAL REBAR #4@24" O.C. W/FIRST BARPLACED 4" ABOVE FOOTING& LAST BAR 4" BELOW TOPOF FOUNDATION WALL.
20" x 10" CONCRETE FOOTING
GRADE
2 #4 BARS CONTINUOUS
5/8" OSB
2" X 4" STUDS @ 16" O.C.
RAIN GUTTER
4" CONC. SLAB
4" GRAVEL
1/2" SHEET ROCK
5/8" DRYWALL
TYVEK HOUSE WRAP, SEAL TAPED AT ALL OPENINGS AND SEAMS
6" FASCIA
PRE- ENGINEEREDROOF TRUSSES
ALUMINUM SOFFIT & FASCIA
7/16" OSB. SHEATHING
TYP. GARAGE WALL DETAILNOT TO SCALE
J-BAR DOWELS & VERTICAL REBAR @ 24" O.C SPACING,EXTEND DOWELS 24" MIN. INTOFOUNDATION WALL, WITH6" MIN. HOOK
30# FELT
SIDINGR-15INSULATION
R-39 FIB. INSUL.
30 YEAR FIBERGLASSSHINGLES
2" X 4" DOUBLE TOP PLATE
2" X 4" BOTTOM PLATE
INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE
1/2" X 10" FOUNDATION BOLTS@32" MAX. SPACING, BOLTSSHALL BE EMBEDDED 7" MIN.
2" X 4" BOTTOM PLATE
INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE 2" X 6" DOUBLE TOP PLATE
1/2" SHEET ROCK
R-50 INSUL.
R-22 FIBERGLASSBLOWN-IN INSULATION
2" X 6" STUDS @ 16" O.C.
1/2" SHEET ROCK
3/4" T&G OSB
FLOOR JOISTS(SEE FRAMING PLAN)
TYP. WALL DETAILNOT TO SCALE
2" X 4" STUDS @ 16" O.C.
PRE- ENGINEEREDROOF TRUSSES
RAIN GUTTER
5/8" OSB
30# FELT30 YEAR ASPHALTSHINGLES
INSTALL 1 ROW OF ICE& WATER SHIELD ON ALLCONDITIONED SPACES
2" X 6" BOTTOM PLATE
VINYL SIDING
ALUMINUM SOFFIT & FASCIA
6" FASCIA
7/16" OSB. SHEATHING
2" X 6" PRESS. TREATED SEAL PLATE
1" OSB RIM BOARD CONTINUOUS
1/2" SHEET ROCK
2" X 4" DOUBLE TOP PLATE
R-11 FIBERGLASS INSULATION
2" X 4' PRESSURETREATED SEAL PLATE
GRADE
8" MIN. THICKNESS 2 COATS ASPHALTDAMP PROOFING
HORIZONTAL REBAR
CONC. FOOTING
VERTICAL REBAR
4" GRAVEL
4" CONC. SLAB
FOAM SEALER
2- #4 REBAR CONTINUOUS
TYVEK HOUSE WRAP, SEAL TAPED AT ALL OPENINGS AND SEAMS
126
8'-11 3/4"
11'-4 1/4"
10 1/2"
7 5/
8" 8'-1
1/2
"
1'-0
5/8
"
8'-1
1/8
"8'
-11
1/4"
6'-8
"
A5A5
BUILDING SECTIONSCALE: 3/8" = 1'
DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE
©
OW
NE
R: J
AY
L. B
AIR
PH
ON
E: (
435)
770-
8636
EM
AIL
: jay
@ba
irdes
igns
.com
WE
B: b
aird
esig
ns.c
om33
6 S
UN
BU
RS
T LN
.R
ICH
MO
ND
, UT,
843
33
2/14/2019
TIT
LE:
NE
IGH
BO
RH
OO
D N
ON
-PR
OF
ITH
OU
SIN
G C
OR
PO
RA
TIO
N
PR
OJE
CT
FO
R:
PAGE #
5
MAIN FLOOR FRAMING PLANSCALE: 1/4" = 1'
ROOF FRAMING PLANSCALE: 1/4" = 1'
FR
AM
ING
PLA
NS
&D
ETA
ILS
DATE:
S
S
S
S
SS
WH
UP
E10E10
3E11E11
E07E07
E10E10
E10E10
E10E10
E10E10
E06E06 E07E07E07E07
E08E08
E05E05
E05E05
E05E05E05E05
E05E05
E05E05 E05E05
E05E05
E05E05
E05E05
E05E05
CO/SD
E02E02
E01E01 E01E01
Unexcavated Garage
Bedroom #6
Cold Storage
Closet
Bedroom #4
Laundry
Storage
Closet
Bath
Closet
Bedroom #5
Craft / Office
Living
Mech.
2x6 WALL
Closet
DN
D/W
REF.
DN
AT
TIC
AC
CE
SS
22"
X30
"
E22E22
E22E22E22E22
E22E22
E21E21E21E21
3
E31E31
3
E31E31E27E27E22E22 E22E22
3E31E31
WP
E23E23
E22E22 E22E22
GFCI
E25E25
E26E26
E22E22
E22E22
E22E22
E22E22
E22E22
E22E22
E20E20
E27E27
3E31E31
E22E22
E22E22
E22E22
E27E27
GFCI
E25E25
E26E26
E22E22
TVE29E29
E28E28
E27E27E22E22
E27E27
E27E27
E27E27
E22E22
3E31E31
4
E24E24
4E24E24
3
E31E31
4
E24E24
4E24E24
E22E22E22E22 E22E22E28E28
3E31E31
E22E22
E22E22
3 E31E31
E27E27
E27E27
E22E22
TV E29E29
E28E28
4
E24E24
4
E24E24
3
E31E31E22E22
E22E22
T
E30E30
E22E22
E22E22
3 E31E31
E27E27
E21E21
WPE23E23
E27E27E27E27E27E27
E27E27 E27E274
E24E24
4
E24E24GFCI
E25E25 E22E22 E22E22 E22E22E22E22E22E22E22E22 E22E22E22E22
E21E21
WP
E23E23
3E31E31
4E24E244
E24E24
E19E19
E19E19
SD
E18E18
SD
E18E18
SD
E18E18
RE17E17
RE17E17
RE17E17
RE17E17
RE17E17
E19E19
E19E19
E19E19
E19E19
E19E19
RE17E17
RE17E17
E19E19
RE17E17
RE17E17
RE17E17
RE17E17
RE17E17
RE17E17
RE17E17
E16E16
E16E16
CO/SD E13E13
E15E15
E15E15
E14E14
E12E12E12E12
Stairwell
Garage
Bedroom #3
Linen
FamilyMaster Bdrm
Pantry
W.I.C.
Closet
Closet
Bedroom #2
Closet
Porch
Kitchen
Entry
Dining
Bath
MasterBath
CONC. PATIO12' x 12'
(2) 2X4 W
ALLS
FO
R F
LUE
CH
AS
E
W
W
SWITCH CONTROLS LIGHTAT BOTTOM OF THE STAIRS
SD
44
3TV
FLUORESCENT LIGHTS(SEE PLAN FOR SIZE)
R
T
C5/TV CAT5 w/ TV
SYMBOL DESCRIPTION
ELECTRICAL LEGEND
THREE WAY SWITCH
THERMOSTAT
LIGHT BAR W/MIRROR
FOUR WAY SWITCH
LIGHT FIXTURE
EXTERIOR LIGHT
SMOKE DETECTOR
SINGLE POLE SWITCH
DUPLEX (WEATHERPROOF)
GFCI OUTLET
110V /DUPLEX OUTLET
220V OUTLET
BREAKER PANEL
110V /FLOOR DUPLEX OUTLET
LIGHT HALF CONE
EYEBALL (ROTATED)
CEILING FAN (LIGHTS)
110V /QUADRUPLEX
RECESSED LIGHT
TELEVISION
TELEPHONE
BATHROOM EXHAUST FAN
CHANDELIER
DUAL SPOTLIGHT
WP
GFC
I
INTERCOM
MASTER ELECTRICAL SCHEDULENUMBER QTY FLOOR ATTACHED TO DESCRIPTIONE01 2 0 CEILING BARE BULBE02 1 0 CEILING CO/SMOKE DETECTORE05 11 0 CEILING TRADITIONAL FLUSH DOMEE06 1 0 WALL 220VE07 3 0 WALL DUPLEXE08 1 0 WALL ELECTRICAL PANELE10 5 0 WALL SINGLE POLEE11 1 0 WALL THREE WAYE12 2 1 CEILING BARE BULBE13 1 1 CEILING CO/SMOKE DETECTORE14 1 1 CEILING CEILING DUPLEXE15 2 1 CEILING CEILING FAN (LIGHTS)E16 2 1 CEILING EXHAUSTE17 14 1 CEILING RECESSED DOWN LIGHTE18 3 1 CEILING SMOKE DETECTORE19 8 1 CEILING TRADITIONAL FLUSH DOMEE20 1 1 WALL 220VE21 4 1 WALL CAGED LANTERNE22 38 1 WALL DUPLEXE23 3 1 WALL DUPLEX (WEATHERPROOF)E24 10 1 WALL FOUR WAYE25 3 1 WALL GFCIE26 2 1 WALL LIGHT BAR (MIRROR)E27 15 1 WALL SINGLE POLEE28 3 1 WALL TELEPHONE JACKE29 2 1 WALL TELEVISION JACKE30 1 1 WALL THERMOSTATE31 11 1 WALL THREE WAY
DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE
©
OW
NE
R: J
AY
L. B
AIR
PH
ON
E: (
435)
770-
8636
EM
AIL
: jay
@ba
irdes
igns
.com
WE
B: b
aird
esig
ns.c
om33
6 S
UN
BU
RS
T LN
.R
ICH
MO
ND
, UT,
843
33
2/14/2019
TIT
LE:
NE
IGH
BO
RH
OO
D N
ON
-PR
OF
ITH
OU
SIN
G C
OR
PO
RA
TIO
N
PR
OJE
CT
FO
R:
PAGE #
6
BASEMENT FLOOR ELECTRICAL PLANSCALE: 1/4" = 1'
MAIN FLOOR ELECTRICAL PLANSCALE: 1/4" = 1'
ELE
CT
RIC
AL
PLA
NS
DATE: