THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit...

6
D O N O T S C A L E 1 1 " X 1 7 " P R I N T S T H E Y A R E N O T T O S C A L E © OWNER: JAY L. BAIR PHONE: (435)770-8636 EMAIL: [email protected] WEB: bairdesigns.com 336 SUNBURST LN. RICHMOND, UT, 84333 2/14/2019 T I T L E : NEIGHBORHOOD NON-PROFIT HOUSING CORPORATION COVER PAGE THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING CORPORATION C O N T E N T S : 1. COVER PAGE 2. FOUNDATION / BASEMENT FLOOR PLAN 3. MAIN FLOOR PLAN 4. ELEVATIONS 5. FRAMING PLANS & DETAILS 6. ELECTRICAL PLANS P R O J E C T F O R : P A G E # 1 D A T E :

Transcript of THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit...

Page 1: THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit housing corporation contents: 1. cover page 2. ... all construction and details shall

DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE

©

OW

NE

R: J

AY

L. B

AIR

PH

ON

E: (

435)

770-

8636

EM

AIL

: jay

@ba

irdes

igns

.com

WE

B: b

aird

esig

ns.c

om33

6 S

UN

BU

RS

T LN

.R

ICH

MO

ND

, UT,

843

33

2/14/2019

TIT

LE:

NE

IGH

BO

RH

OO

D N

ON

-PR

OF

ITH

OU

SIN

G C

OR

PO

RA

TIO

NC

OV

ER

PA

GE

THE ASPENNEIGHBORHOOD NON-PROFIT HOUSING CORPORATION

CONTENTS:1. COVER PAGE2. FOUNDATION / BASEMENT FLOOR PLAN3. MAIN FLOOR PLAN4. ELEVATIONS5. FRAMING PLANS & DETAILS6. ELECTRICAL PLANS

PR

OJE

CT

FO

R:

PAGE #

1

DATE:

Page 2: THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit housing corporation contents: 1. cover page 2. ... all construction and details shall

S

S

S

S

SS

WH

3068

4040LS

4040LS 4040LS 4040LS

4068

2868

4068

2868

4068

2868

2868

3068

2468

2868

5068

4068

2868

UP

A5

A5

A5

A5

5'-4"6'-4" 6'-3"17'-7"

5'-9 1/2" 5'-7"

4'-2 1/4"

6'-8

1/4

"

12'-0 1/2" 12'-1"

24'-1 1/2" 20'-6" 11'-4 1/2"

56'

13'-2

"3

1/2"

8'-4

"3

1/2"

2'-1

" 3 1/

2"11

'-10"

36'-3

1/2

"

1'

6'-1"5'-1"

11'-2"3 1/2"

6'-1"3 1/2"

23'-10"3 1/2"

2'-1"3 1/2"

11'-8"

56'

18'

5'-9

1/2

"

11'-1

0"8"

23'-9

1/2

"

36'-3

1/2

"

1'

3'-5

"3'

3 1/

2"4'

-5 1

/2"

13'-5

1/4

"

3 1/

2"

3'-5

"3

1/2"

7'-9

"3

1/2"

3'-8

"

9'-2

"5

1/2"

3'-1

1"3

1/2"

3'-3

3/4

"3

1/2"

11'-8

1/2

"

5'-5"1'-5"

3 1/2"3'-4"

3 1/2"8'-1"

3 1/2"2'-1"

3 1/2"3'-5" 3 1/2"

4 1/2"

3 1/2"5'-4"

3'-9"3 1/2"

6'-5 1/2"

22'-10" x 23'-2"

23'-9" x 13'

20'-6" x 4'-2"

9'-4" x 12'-1"

6'-5" x 11'-4"8' x 11'-4"

2' x 6'

10'-7" x 10'-5"

2' x 6'-3"

6'-1" x 2'

2' x 4'-8"

5'-7" x 8'-3"

10'-1" x 10'-9"

6' x 8'-9"

6' x 3'-10"

Unexcavated Garage

Bedroom #6

Cold Storage

Closet

Bedroom #4

Laundry

Storage

Closet

Bath

Closet

Bedroom #5

Craft / Office

Living

Mech.

2x6 WALL

Closet

GENERAL NOTES:1. ALL CONSTRUCTION AND DETAILSSHALL COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE AND STATE AND LOCAL CODES.2.CONTRACTOR SHALL BERESPONSIBLE FOR THE ACCURATEPLACEMENT OF THE BUILDING ONTHE SITE. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELDBEFORE ANY WORK PROCEEDS.3. GAS/PROPANE FORCED AIRHEAT THRU-OUT. SUBCONTRACTOR TO SUPPLY GENERAL CONTRACTORWITH COMPLETE SHOP DRAWINGSAND HEAT LOSS CALCULATIONS.ALL WARM AIR DUCTS AND COLDAIR RETURNS SHOWN ARE FOR REFERENCE ONLY.4. FLOOR JOISTS ARE TO BE AS PER FRAMING PLAN OR COMPATIBLE.FLOOR DEFLECTION MUST BEL/480 OR BETTER.5. CONTRACTOR SHALL VERIFYAND BE RESPONSIBLE FORALL CONSTRUCTION DETAILS.6. 5/8" TYPE "X" SHEET ROCK AT GARAGEWALLS CEILING AND BEARING WALLSCOMMON TO HOUSE. INSULATE HOUSE WALLS.7. WIRE FOR TELEPHONE AND TELEVISIONJACKS (UL LISTED) GENERAL CONTRACTORTO COORDINATE LOCATIONS WITH OWNER.ALL ELECTRICAL PARTS SHOWN ARE FOR REFERENCE ONLY. CHECK WITH OWNER FOREXACT LOCATION.8. CONTRACTOR SHALL VERIFY ALL BEAMAND JOISTS SIZES AND SPACING.9. GENERAL CONTRACTOR TO VERIFY WITHOWNER ON ALL EXTERIOR DOOR AND WINDOW TYPES AND MANUFACTURER PRIORTO THE STARTING OF ANY FRAMING.10. SEE FOUNDATION PLAN FOR LOCATIONSOF FOUNDATION STRAPS.11. ALL HEADERS & BEAMS ARE TO BE 2X10DF #2 BTR UNLESS NOTED OTHER WISE.12. ALL WINDOWS TO BE DOUBLE PANELOW-E GRADE13. ALL EXTERIOR BASEMENT WALLS TO HAVEA MINIMUM OF R-11 INSULATIONS14. ALL EXTERIOR ABOVE GRADE WALLS TOHAVE A MINIMUM OF R-21 INSULATION UNLESSNOTED OTHER WISE.15. ALL ATTIC SPACES TO HAVE A MINIMUMOF R-50 INSULATION UNLESS NOTED OTHER16. ALL DOORS SEPARATING GARAGE FROMLIVING SPACE AND FURNACE ROOM TO MEETOR EXCEED CODE R302.5.1. (20-MINUTE FIRE-RATED DOORS, EQUIPPED WITH A SELF-CLOSING DEVICE.)17. COMBUSTION AIR FOR FURNACE ANDWATER HEATERS TO MEET OR EXCEED G240718. CLOTHES DRYER EXHAUST VENTS TOMEET OR EXCEED M1502 (VENTING CANNOTPENETRATE FIRE RATED CONSTRUCTIONMATERIALS).19. ARC FAULT PROTECTION TO BE PROVIDEDAS PER 3802.12, AND BE COMBINATION TYPE.20. TAMPER RESISTANT OUTLETS ARE TO BEINSTALLED THROUGHOUT THE ENTIREPROJECT.21. EXTERIOR OUTLETS WILL BE REQUIRED TOHAVE COVERS OVER THEM TO CONFORMWITH SECTION E3902.8 THROUGH E3902.10

GUARDRAIL NOTES:1. 36" (MIN) HIGH GUARDRAILS AREREQUIRED FOR UNENCLOSED FLOORAND ROOF OPENINGS, OPEN ANDGLAZED SIDES OF STAIRWAYS,LANDINGS, DECKS, RAMPS, ANDPORCHES, WHICH ARE MORE THAN 30INCHES ABOVE GRADE OR A FLOOR OROTHER SURFACE BELOW.2. OPEN GUARDRAILS SHALL HAVEINTERMEDIATE RAIL SPACING ORPATTERN SUCH THAT A 4-INCH SPHERECANNOT PASS THROUGH AND THETRIANGULAR AREA FORMED BY TREAD,RISER AND GUARDRAIL SO THAT A 4-INCH SPHERE CANNOT PASS THR0UGH.3. HAND RAIL REQUIRED WHEN (40 ORMORE RISERS ARE USED PER IRC311.7.8

DN

CONC. PATIO12' x 12'

(2) 2X4 W

ALLS

FO

R F

LUE

CH

AS

E

SYMBOLS:

HEAT VENT

WATER FAUCETW

FLOOR DRAIN

BEARING WALLS2" X 4" BOTTOM PLATE

INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE

DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE

©

OW

NE

R: J

AY

L. B

AIR

PH

ON

E: (

435)

770-

8636

EM

AIL

: jay

@ba

irdes

igns

.com

WE

B: b

aird

esig

ns.c

om33

6 S

UN

BU

RS

T LN

.R

ICH

MO

ND

, UT,

843

33

2/14/2019

TIT

LE:

NE

IGH

BO

RH

OO

D N

ON

-PR

OF

ITH

OU

SIN

G C

OR

PO

RA

TIO

N

PR

OJE

CT

FO

R:

PAGE #

2

1432 SQ.FT. UNFINISHED BASEMENTFOUNDATION & BASEMENT FLOOR PLAN

SCALE: 1/4" = 1'

FO

UN

DA

TIO

N &

BA

SE

ME

NT

FLO

OR

PLA

N

DOORS ARE TO BE CENTERED IN HALLWAYS & CLOSETS.DOORS NOT CENTERED WILL BE 5" (ROUGH OPENING EDGE)

FROM NEAREST WALL AND 9" FROM NEAREST FOUNDATION WALL.

DATE:

Page 3: THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit housing corporation contents: 1. cover page 2. ... all construction and details shall

GENERAL NOTES:1. ALL CONSTRUCTION AND DETAILSSHALL COMPLY WITH THE INTERNATIONAL RESIDENTIAL CODE AND STATE AND LOCAL CODES.2.CONTRACTOR SHALL BERESPONSIBLE FOR THE ACCURATEPLACEMENT OF THE BUILDING ONTHE SITE. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELDBEFORE ANY WORK PROCEEDS.3. GAS/PROPANE FORCED AIRHEAT THRU-OUT. SUBCONTRACTOR TO SUPPLY GENERAL CONTRACTORWITH COMPLETE SHOP DRAWINGSAND HEAT LOSS CALCULATIONS.ALL WARM AIR DUCTS AND COLDAIR RETURNS SHOWN ARE FOR REFERENCE ONLY.4. FLOOR JOISTS ARE TO BE AS PER FRAMING PLAN OR COMPATIBLE.FLOOR DEFLECTION MUST BEL/480 OR BETTER.5. CONTRACTOR SHALL VERIFYAND BE RESPONSIBLE FORALL CONSTRUCTION DETAILS.6. 5/8" TYPE "X" SHEET ROCK AT GARAGEWALLS CEILING AND BEARING WALLSCOMMON TO HOUSE. INSULATE HOUSE WALLS.7. WIRE FOR TELEPHONE AND TELEVISIONJACKS (UL LISTED) GENERAL CONTRACTORTO COORDINATE LOCATIONS WITH OWNER.ALL ELECTRICAL PARTS SHOWN ARE FOR REFERENCE ONLY. CHECK WITH OWNER FOREXACT LOCATION.8. CONTRACTOR SHALL VERIFY ALL BEAMAND JOISTS SIZES AND SPACING.9. GENERAL CONTRACTOR TO VERIFY WITHOWNER ON ALL EXTERIOR DOOR AND WINDOW TYPES AND MANUFACTURER PRIORTO THE STARTING OF ANY FRAMING.10. SEE FOUNDATION PLAN FOR LOCATIONSOF FOUNDATION STRAPS.11. ALL HEADERS & BEAMS ARE TO BE 2X10DF #2 BTR UNLESS NOTED OTHER WISE.12. ALL WINDOWS TO BE DOUBLE PANELOW-E GRADE13. ALL EXTERIOR BASEMENT WALLS TO HAVEA MINIMUM OF R-11 INSULATIONS14. ALL EXTERIOR ABOVE GRADE WALLS TOHAVE A MINIMUM OF R-21 INSULATION UNLESSNOTED OTHER WISE.15. ALL ATTIC SPACES TO HAVE A MINIMUMOF R-50 INSULATION UNLESS NOTED OTHER16. ALL DOORS SEPARATING GARAGE FROMLIVING SPACE AND FURNACE ROOM TO MEETOR EXCEED CODE R302.5.1. (20-MINUTE FIRE-RATED DOORS, EQUIPPED WITH A SELF-CLOSING DEVICE.)17. COMBUSTION AIR FOR FURNACE ANDWATER HEATERS TO MEET OR EXCEED G240718. CLOTHES DRYER EXHAUST VENTS TOMEET OR EXCEED M1502 (VENTING CANNOTPENETRATE FIRE RATED CONSTRUCTIONMATERIALS).19. ARC FAULT PROTECTION TO BE PROVIDEDAS PER 3802.12, AND BE COMBINATION TYPE.20. TAMPER RESISTANT OUTLETS ARE TO BEINSTALLED THROUGHOUT THE ENTIREPROJECT.21. EXTERIOR OUTLETS WILL BE REQUIRED TOHAVE COVERS OVER THEM TO CONFORMWITH SECTION E3902.8 THROUGH E3902.10

GUARDRAIL NOTES:1. 36" (MIN) HIGH GUARDRAILS AREREQUIRED FOR UNENCLOSED FLOORAND ROOF OPENINGS, OPEN ANDGLAZED SIDES OF STAIRWAYS,LANDINGS, DECKS, RAMPS, ANDPORCHES, WHICH ARE MORE THAN 30INCHES ABOVE GRADE OR A FLOOR OROTHER SURFACE BELOW.2. OPEN GUARDRAILS SHALL HAVEINTERMEDIATE RAIL SPACING ORPATTERN SUCH THAT A 4-INCH SPHERECANNOT PASS THROUGH AND THETRIANGULAR AREA FORMED BY TREAD,RISER AND GUARDRAIL SO THAT A 4-INCH SPHERE CANNOT PASS THR0UGH.3. HAND RAIL REQUIRED WHEN (40 ORMORE RISERS ARE USED PER IRC311.7.8

DN

CONC. PATIO12' x 12'

(2) 2X4 W

ALLS

FO

R F

LUE

CH

AS

E

SYMBOLS:

HEAT VENT

WATER FAUCETW

FLOOR DRAIN

BEARING WALLS2" X 4" BOTTOM PLATE

INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE

DN

D/W

REF.

16080

5040LS2630FX3068

5040LS

2228

LS

2868

40682868

2468

4068

3068

2868

2468

3068

2468

3630LS

6068

5050LS 5040LS

2068

3868

2668

DNA

TT

ICA

CC

ES

S 2

2"X

30"

A5

A5

A5

A5

6'-7"12'14'-6"4'-11 1/2"5 1/2"

5'-1" 4'-11"5 1/2"

5'-1" 5'-1"5 1/2"

2'-2"

2'-2

"

3'-0 1/16"

2'-5

"

3 1/2"11'-8 1/2" 11'-6 1/2"

3 1/2"2'-4" 6'-4 1/2" 2'

23'-10" 10'-8 1/2"3 1/2"

10'5 1/2"

10'-2"5 1/2"

55'-11"

18'

5'-3

"3

1/2"

5 1/

2"7'

-3"

3 1/

2"4'

5 1/

2"23

'-3"

3 1/

2"

36'

6'

3'-1

0"4'

-7"

5 1/

2"10

'-1"

3 1/

2"2'

-1" 3

1/2"

8'-5

"3

1/2"

13'-7

1/2

"5

1/2"

36'

6'

5 1/2"5'-6"5'-7"

5 1/2"11'-1"

3 1/2"5'

7"38'-0 1/2"

5 1/2"55'-11"

4'-2"3 1/2"

8'-4"3 1/2"

2'-6" 7'-8"

6'-11"3 1/2"

3'-4" 3 1/2" 4'-7"3 1/2"

5'-3 1/2"3 1/2"

3'-5"3 1/2"

6'-5 1/2"

3'-5"3 1/2"

1'-2"

3 1/2"5'

2'-1

"3

1/2"

9'-1

"

5'-2

"3'

-2"

3 1/

2"5'

3 1/

2"3'

-5"

3 1/

2"7'

-1"

3 1/

2"4'

-1"

5 1/

2"5'

-6 1

/2"

17'-4

"3

1/2"

2'-1

"3

1/2"

5'-8

"3'

-5"

135°

135°

20'-6" x 5'-1"

4'-6" x 2'

14'-5" x 17'-3"

1'-1" x 4'-7"

6'-5" x 8'-4"

4'-11" x 2'

23'-2" x 23'-2"

11' x 13'-7"

10'-1" x 10'

12'-10" x 11'-6"

5' x 9'

4'-11" x 8'-3"

10'-1" x 11'-5"

10'-8" x 11'-6"

3'-11" x 3'-11"

4'-11" x 4'-11"

7'-3" x 11'-9"

3'-3" x 2'

Stairwell

Garage

Bedroom #3

Linen

FamilyMaster Bdrm

Pantry

W.I.C.

Closet

Closet

Bedroom #2

Closet

Porch

Kitchen

Entry

Dining

Bath

MasterBath

CONC. PATIO12' x 12'

(2) 2X4 W

ALLS

FO

R F

LUE

CH

AS

E

W

W

DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE

©

OW

NE

R: J

AY

L. B

AIR

PH

ON

E: (

435)

770-

8636

EM

AIL

: jay

@ba

irdes

igns

.com

WE

B: b

aird

esig

ns.c

om33

6 S

UN

BU

RS

T LN

.R

ICH

MO

ND

, UT,

843

33

2/14/2019

TIT

LE:

NE

IGH

BO

RH

OO

D N

ON

-PR

OF

ITH

OU

SIN

G C

OR

PO

RA

TIO

N

PR

OJE

CT

FO

R:

PAGE #

3

1321 SQ.FT.MAIN FLOOR PLAN

SCALE: 1/4' = 1'

MA

IN F

LOO

R P

LAN

DOORS ARE TO BE CENTERED IN HALLWAYS & CLOSETS.DOORS NOT CENTERED WILL BE 5" (ROUGH OPENING EDGE)

FROM NEAREST WALL AND 9" FROM NEAREST FOUNDATION WALL.

DATE:

Page 4: THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit housing corporation contents: 1. cover page 2. ... all construction and details shall

6126

12

6123

12

18" O.H. TYP.

ALUMINUM SOFFIT& FASCIA TYP.

3-1/2" CORNERBOARD TYP.

3-1/2" TRIM BOARD TYP.

CULTURED STONE

VINYL SIDING

VINYL VERTICAL SIDING

CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE

PROPOSED GRADEVINYL RAILING

VINYL VERTICAL SIDING

VINYL SIDING

MIN. 30 YEAR ASPHALT SHINGLES

BOTTOM OF FOOTINGS TO BE AMIN. OF 30" BELOW FINISHED GRADE

INSTALL EGRESS WINDOW WELL& WINDOW WELL COVER

(NOT SHOWN)

VINYL SIDING

18" O.H. TYP.

3-1/2" CORNERBOARD TYP.

3-1/2" TRIM BOARD TYP.

CULTUREDSTONE

612

312

612

CONC. STEPS

CONC. DRIVEWAY

18" O.H. TYP.

ALUMINUM SOFFIT& FASCIA TYP.

3-1/2" CORNERBOARD TYP.

CONC. SIDEWALK

VINYL SIDING

CULTURED STONE

CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE

PROPOSED GRADE

MIN. 30 YEAR ASPHALT SHINGLES

BOTTOM OF FOOTINGS TO BE AMIN. OF 30" BELOW FINISHED GRADE

18" O.H. TYP.

3-1/2" CORNERBOARD TYP.

12'x12" CONC. PATIO

612

INSTALL EGRESS WINDOW WELL& WINDOW WELL COVER

(NOT SHOWN)

18" O.H. TYP.

INSTALL EGRESS WINDOW WELL& WINDOW WELL COVER

(NOT SHOWN)

12'x12" CONC. PATIO

3-1/2" CORNERBOARD TYP.

ALUMINUM SOFFIT& FASCIA TYP.

CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE

PROPOSED GRADE

VINYL SIDING

MIN. 30 YEAR ASPHALT SHINGLES

VINYL SIDING

612

612

612

312

CONC. STEPS

CONC. DRIVEWAY

18" O.H. TYP.

ALUMINUM SOFFIT& FASCIA TYP.

3-1/2" CORNERBOARD TYP.

VINYL SIDING

CULTURED STONE

CONC. STEPS, NUMBER OF RISERS & TREADSTO BE DETERMINED BY FINAL GRADE

PROPOSED GRADE

MIN. 30 YEAR ASPHALT SHINGLES

18" O.H. TYP.

3-1/2" CORNERBOARD TYP.

12'x12" CONC. PATIO

DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE

©

OW

NE

R: J

AY

L. B

AIR

PH

ON

E: (

435)

770-

8636

EM

AIL

: jay

@ba

irdes

igns

.com

WE

B: b

aird

esig

ns.c

om33

6 S

UN

BU

RS

T LN

.R

ICH

MO

ND

, UT,

843

33

2/14/2019

TIT

LE:

NE

IGH

BO

RH

OO

D N

ON

-PR

OF

ITH

OU

SIN

G C

OR

PO

RA

TIO

N

PR

OJE

CT

FO

R:

PAGE #

4

FRONT ELEVATIONSCALE: 1/4" = 1'

LEFT ELEVATIONSCALE: 1/4" = 1'

REAR ELEVATIONSCALE: 1/4" = 1'

RIGHT ELEVATIONSCALE: 1/4" = 1'

ELE

VA

TIO

NS

DATE:

Page 5: THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit housing corporation contents: 1. cover page 2. ... all construction and details shall

S

S

S

S

SS

WH

3068

4040LS

4040LS 4040LS 4040LS

4068

2868

4068

2868

4068

2868

2868

3068

2468

2868

5068

4068

2868

UP

2x6 WALL

FLOOR JOISTS @ 16" O.C.

SPECIFIED BY OTHERS

DN

REF.

16080

5040LS2630FX3068

5040LS

2228

LS

2868

40682868

2468

4068

3068

2868

2468

3068

2468

3630LS

6068

5050LS 5040LS

2068

3868

2668

DN

AT

TIC

AC

CE

SS

22"

X30

"

CONC. PATIO12' x 12'

(2) 2X4 W

ALLS

FO

R F

LUE

CH

AS

E

W

W

ENGINEERED TRUSSES @ 24" O.C.

SPECIFIED BY OTHERS

LOCATION OF FALSE DORMER

T

126

T

2x TREATED MUDSILL

SILL SEALER

CONCRETE FOUNDATION8" MIN. THICKNESS

HORIZONTAL REBAR #4@24" O.C. W/FIRST BARPLACED 4" ABOVE FOOTING& LAST BAR 4" BELOW TOPOF FOUNDATION WALL.

20" x 10" CONCRETE FOOTING

GRADE

2 #4 BARS CONTINUOUS

5/8" OSB

2" X 4" STUDS @ 16" O.C.

RAIN GUTTER

4" CONC. SLAB

4" GRAVEL

1/2" SHEET ROCK

5/8" DRYWALL

TYVEK HOUSE WRAP, SEAL TAPED AT ALL OPENINGS AND SEAMS

6" FASCIA

PRE- ENGINEEREDROOF TRUSSES

ALUMINUM SOFFIT & FASCIA

7/16" OSB. SHEATHING

TYP. GARAGE WALL DETAILNOT TO SCALE

J-BAR DOWELS & VERTICAL REBAR @ 24" O.C SPACING,EXTEND DOWELS 24" MIN. INTOFOUNDATION WALL, WITH6" MIN. HOOK

30# FELT

SIDINGR-15INSULATION

R-39 FIB. INSUL.

30 YEAR FIBERGLASSSHINGLES

2" X 4" DOUBLE TOP PLATE

2" X 4" BOTTOM PLATE

INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE

1/2" X 10" FOUNDATION BOLTS@32" MAX. SPACING, BOLTSSHALL BE EMBEDDED 7" MIN.

2" X 4" BOTTOM PLATE

INSTALL ICE & WATER SHIELDON ALL CONDITIONED SPACESMUST EXTEND 24" INSIDETHE EXTERIOR WALL LINE 2" X 6" DOUBLE TOP PLATE

1/2" SHEET ROCK

R-50 INSUL.

R-22 FIBERGLASSBLOWN-IN INSULATION

2" X 6" STUDS @ 16" O.C.

1/2" SHEET ROCK

3/4" T&G OSB

FLOOR JOISTS(SEE FRAMING PLAN)

TYP. WALL DETAILNOT TO SCALE

2" X 4" STUDS @ 16" O.C.

PRE- ENGINEEREDROOF TRUSSES

RAIN GUTTER

5/8" OSB

30# FELT30 YEAR ASPHALTSHINGLES

INSTALL 1 ROW OF ICE& WATER SHIELD ON ALLCONDITIONED SPACES

2" X 6" BOTTOM PLATE

VINYL SIDING

ALUMINUM SOFFIT & FASCIA

6" FASCIA

7/16" OSB. SHEATHING

2" X 6" PRESS. TREATED SEAL PLATE

1" OSB RIM BOARD CONTINUOUS

1/2" SHEET ROCK

2" X 4" DOUBLE TOP PLATE

R-11 FIBERGLASS INSULATION

2" X 4' PRESSURETREATED SEAL PLATE

GRADE

8" MIN. THICKNESS 2 COATS ASPHALTDAMP PROOFING

HORIZONTAL REBAR

CONC. FOOTING

VERTICAL REBAR

4" GRAVEL

4" CONC. SLAB

FOAM SEALER

2- #4 REBAR CONTINUOUS

TYVEK HOUSE WRAP, SEAL TAPED AT ALL OPENINGS AND SEAMS

126

8'-11 3/4"

11'-4 1/4"

10 1/2"

7 5/

8" 8'-1

1/2

"

1'-0

5/8

"

8'-1

1/8

"8'

-11

1/4"

6'-8

"

A5A5

BUILDING SECTIONSCALE: 3/8" = 1'

DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE

©

OW

NE

R: J

AY

L. B

AIR

PH

ON

E: (

435)

770-

8636

EM

AIL

: jay

@ba

irdes

igns

.com

WE

B: b

aird

esig

ns.c

om33

6 S

UN

BU

RS

T LN

.R

ICH

MO

ND

, UT,

843

33

2/14/2019

TIT

LE:

NE

IGH

BO

RH

OO

D N

ON

-PR

OF

ITH

OU

SIN

G C

OR

PO

RA

TIO

N

PR

OJE

CT

FO

R:

PAGE #

5

MAIN FLOOR FRAMING PLANSCALE: 1/4" = 1'

ROOF FRAMING PLANSCALE: 1/4" = 1'

FR

AM

ING

PLA

NS

&D

ETA

ILS

DATE:

Page 6: THE ASPEN NEIGHBORHOOD NON-PROFIT HOUSING … · 2019-04-24 · the aspen neighborhood non-profit housing corporation contents: 1. cover page 2. ... all construction and details shall

S

S

S

S

SS

WH

UP

E10E10

3E11E11

E07E07

E10E10

E10E10

E10E10

E10E10

E06E06 E07E07E07E07

E08E08

E05E05

E05E05

E05E05E05E05

E05E05

E05E05 E05E05

E05E05

E05E05

E05E05

E05E05

CO/SD

E02E02

E01E01 E01E01

Unexcavated Garage

Bedroom #6

Cold Storage

Closet

Bedroom #4

Laundry

Storage

Closet

Bath

Closet

Bedroom #5

Craft / Office

Living

Mech.

2x6 WALL

Closet

DN

D/W

REF.

DN

AT

TIC

AC

CE

SS

22"

X30

"

E22E22

E22E22E22E22

E22E22

E21E21E21E21

3

E31E31

3

E31E31E27E27E22E22 E22E22

3E31E31

WP

E23E23

E22E22 E22E22

GFCI

E25E25

E26E26

E22E22

E22E22

E22E22

E22E22

E22E22

E22E22

E20E20

E27E27

3E31E31

E22E22

E22E22

E22E22

E27E27

GFCI

E25E25

E26E26

E22E22

TVE29E29

E28E28

E27E27E22E22

E27E27

E27E27

E27E27

E22E22

3E31E31

4

E24E24

4E24E24

3

E31E31

4

E24E24

4E24E24

E22E22E22E22 E22E22E28E28

3E31E31

E22E22

E22E22

3 E31E31

E27E27

E27E27

E22E22

TV E29E29

E28E28

4

E24E24

4

E24E24

3

E31E31E22E22

E22E22

T

E30E30

E22E22

E22E22

3 E31E31

E27E27

E21E21

WPE23E23

E27E27E27E27E27E27

E27E27 E27E274

E24E24

4

E24E24GFCI

E25E25 E22E22 E22E22 E22E22E22E22E22E22E22E22 E22E22E22E22

E21E21

WP

E23E23

3E31E31

4E24E244

E24E24

E19E19

E19E19

SD

E18E18

SD

E18E18

SD

E18E18

RE17E17

RE17E17

RE17E17

RE17E17

RE17E17

E19E19

E19E19

E19E19

E19E19

E19E19

RE17E17

RE17E17

E19E19

RE17E17

RE17E17

RE17E17

RE17E17

RE17E17

RE17E17

RE17E17

E16E16

E16E16

CO/SD E13E13

E15E15

E15E15

E14E14

E12E12E12E12

Stairwell

Garage

Bedroom #3

Linen

FamilyMaster Bdrm

Pantry

W.I.C.

Closet

Closet

Bedroom #2

Closet

Porch

Kitchen

Entry

Dining

Bath

MasterBath

CONC. PATIO12' x 12'

(2) 2X4 W

ALLS

FO

R F

LUE

CH

AS

E

W

W

SWITCH CONTROLS LIGHTAT BOTTOM OF THE STAIRS

SD

44

3TV

FLUORESCENT LIGHTS(SEE PLAN FOR SIZE)

R

T

C5/TV CAT5 w/ TV

SYMBOL DESCRIPTION

ELECTRICAL LEGEND

THREE WAY SWITCH

THERMOSTAT

LIGHT BAR W/MIRROR

FOUR WAY SWITCH

LIGHT FIXTURE

EXTERIOR LIGHT

SMOKE DETECTOR

SINGLE POLE SWITCH

DUPLEX (WEATHERPROOF)

GFCI OUTLET

110V /DUPLEX OUTLET

220V OUTLET

BREAKER PANEL

110V /FLOOR DUPLEX OUTLET

LIGHT HALF CONE

EYEBALL (ROTATED)

CEILING FAN (LIGHTS)

110V /QUADRUPLEX

RECESSED LIGHT

TELEVISION

TELEPHONE

BATHROOM EXHAUST FAN

CHANDELIER

DUAL SPOTLIGHT

WP

GFC

I

INTERCOM

MASTER ELECTRICAL SCHEDULENUMBER QTY FLOOR ATTACHED TO DESCRIPTIONE01 2 0 CEILING BARE BULBE02 1 0 CEILING CO/SMOKE DETECTORE05 11 0 CEILING TRADITIONAL FLUSH DOMEE06 1 0 WALL 220VE07 3 0 WALL DUPLEXE08 1 0 WALL ELECTRICAL PANELE10 5 0 WALL SINGLE POLEE11 1 0 WALL THREE WAYE12 2 1 CEILING BARE BULBE13 1 1 CEILING CO/SMOKE DETECTORE14 1 1 CEILING CEILING DUPLEXE15 2 1 CEILING CEILING FAN (LIGHTS)E16 2 1 CEILING EXHAUSTE17 14 1 CEILING RECESSED DOWN LIGHTE18 3 1 CEILING SMOKE DETECTORE19 8 1 CEILING TRADITIONAL FLUSH DOMEE20 1 1 WALL 220VE21 4 1 WALL CAGED LANTERNE22 38 1 WALL DUPLEXE23 3 1 WALL DUPLEX (WEATHERPROOF)E24 10 1 WALL FOUR WAYE25 3 1 WALL GFCIE26 2 1 WALL LIGHT BAR (MIRROR)E27 15 1 WALL SINGLE POLEE28 3 1 WALL TELEPHONE JACKE29 2 1 WALL TELEVISION JACKE30 1 1 WALL THERMOSTATE31 11 1 WALL THREE WAY

DO NOT SCALE 11"X17" PRINTSTHEY ARE NOT TO SCALE

©

OW

NE

R: J

AY

L. B

AIR

PH

ON

E: (

435)

770-

8636

EM

AIL

: jay

@ba

irdes

igns

.com

WE

B: b

aird

esig

ns.c

om33

6 S

UN

BU

RS

T LN

.R

ICH

MO

ND

, UT,

843

33

2/14/2019

TIT

LE:

NE

IGH

BO

RH

OO

D N

ON

-PR

OF

ITH

OU

SIN

G C

OR

PO

RA

TIO

N

PR

OJE

CT

FO

R:

PAGE #

6

BASEMENT FLOOR ELECTRICAL PLANSCALE: 1/4" = 1'

MAIN FLOOR ELECTRICAL PLANSCALE: 1/4" = 1'

ELE

CT

RIC

AL

PLA

NS

DATE: