Light Green International Co.Ltd Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME: LED Panel Light
DIM.:
MFR.: Light-green
TYPE:cool white
SPEC.:
SUR.:0.262m*0.563m
WEIGHT:1.5KGTest:U:230.2V I:0.2310A P:26.70W PF:0.5010 Lamp Flux:1454.34x1 lm
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
UNIT:cdC90/270,115.3°
AVERAGE BEAM ANGLE(50%):115.3 DEG
0
110
220
330
440
550
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)
14
18
22
26
30
34
38
42
46
0.0 17.0 34.0S(m)3.00
2.502.001.501.00
0.51000.40000.25000.20000.1500
DATA OF LAMP PHOTOMETRIC DATA Eff: 54.47 lm/WMODELNOMINAL POWER(W)RATED VOLTAGE(V)NOMINAL FLUX(lm)LAMPS INSIDETEST VOLTAGE(V)
Imax(cd)LOR(%)TOTAL FLUX(lm)CIE CLASS up(%) down(%)η
η
S/MH(C0/180)S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360)CIBSE SHR NOMCIBSE SHR MAX
η
η
LGI-C0306WDA-Q282301454.341230.2
505.2100.01454.3DIRECT0.0100.0
1.261.340.0,51.60.0,48.41.251.35
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000] Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 2 Of 12
ZONAL FLUX DIAGRAMAND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM:
γ 5 0- 5 10 5- 10 15 10- 15 20 15- 20 25 20- 25 30 25- 30 35 30- 35 40 35- 40 45 40- 45 50 45- 50 55 50- 55 60 55- 60 65 60- 65 70 65- 70 75 70- 75 80 75- 80 85 80- 85 90 85- 90 95 90- 95 100 95-100 105 100-105 110 105-110 115 110-115 120 115-120 125 120-125 130 125-130 135 130-135 140 135-140 145 140-145 150 145-150 155 150-155 160 155-160 165 160-165 170 165-170 175 170-175 180 175-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp γ Φ Φ
DEG LUMINOUS INTENSITY:cd UNIT:lm
502.9 503.8 504.9 504.3 503.4 503.0 502.8 502.5 12.06 12.06 0.83,0.83496.7 499.7 502.5 500.5 498.0 497.7 498.6 496.8 35.85 47.91 3.29,3.29486.5 492.4 497.3 493.4 488.2 488.9 490.5 487.6 58.69 106.6 7.33,7.33471.8 480.8 489.3 482.4 474.0 475.6 478.9 473.8 79.84 186.4 12.8,12.8452.6 465.2 476.0 466.9 455.0 457.5 461.5 455.3 98.55 285.0 19.6,19.6428.6 444.5 458.5 446.4 431.2 434.3 439.7 431.8 114.0 398.9 27.4,27.4400.0 419.0 434.4 420.9 402.7 406.1 411.4 403.5 125.4 524.4 36.1,36.1367.5 388.7 405.8 390.3 370.1 373.1 379.0 370.7 132.3 656.6 45.1,45.1331.4 353.7 371.5 355.4 334.2 336.3 341.5 333.7 134.3 790.9 54.4,54.4292.8 315.7 333.6 317.2 295.6 296.8 301.4 294.2 131.4 922.3 63.4,63.4252.3 274.5 291.9 276.4 255.4 255.0 259.1 252.2 124.0 1046 71.9,71.9210.8 232.1 248.3 233.9 213.8 212.2 216.9 209.3 112.4 1159 79.7,79.7168.5 188.3 203.3 190.4 171.5 168.9 173.5 165.9 97.41 1256 86.4,86.4126.1 144.2 157.7 146.4 128.9 126.0 128.6 122.9 79.42 1336 91.8,91.884.57 100.7 112.5 102.7 87.06 83.80 84.23 80.54 59.25 1395 95.9,95.945.69 59.42 68.84 61.33 47.91 45.09 43.00 41.93 38.26 1433 98.5,98.513.27 24.79 19.29 26.16 14.20 16.84 10.57 14.71 18.93 1452 99.8,99.81.485 0 0 0 0.3774 0 0 0 2.386 1454 100,100
LUMINANCE LIMITATION CURVESGLARE CLASS ILLUMINANCE (lx)1.15 A 2000 1000 500 <=3001.50 B 2000 1000 500 <=3001.85 C 2000 1000 500 <=3002.20 D 2000 1000 500 <=3002.55 E 2000 1000 500 <=300
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 4 1
2
3468
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)G(DEG) C0/180 C90/27085 1028 149580 1778 267975 2208 293670 2492 311565 2694 325060 2848 335655 2972 343950 3078 350645 3166 3550
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
cc w fc
ρ
ρ
ρ
RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
1.191.04.91.80.71.63.57.51.47.43.40
1.19.00.84.72.62.54.48.43.38.35.32
1.19.96.78.65.55.47.41.36.33.29.26
1.161.02.89.78.69.62.56.51.46.42.39
1.16.98.83.71.61.53.47.42.38.35.32
1.16.95.77.65.55.47.41.36.32.29.26
1.11.98.85.75.67.60.54.49.45.41.38
1.11.95.80.69.60.52.46.42.37.34.31
1.11.92.76.63.54.47.41.36.32.29.26
1.06.94.82.72.64.58.52.48.44.40.37
1.06.91.78.67.58.51.46.41.37.34.31
1.06.89.74.62.53.46.40.36.32.29.26
1.02.90.79.70.62.56.51.46.42.39.36
1.02.88.75.65.57.50.45.40.36.33.30
1.02.86.72.61.53.46.40.36.32.29.26
.00
.84
.70
.59
.50
.43
.38
.34
.30
.27
.24
AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k2
3
4
56789
10
20
30
40
50LAMPS LUMINAIRE BUDGETARY DIAGRAM
2
3
4
H=5H=5
55
66
77
H=8H=8
CONDITIONSFLUX 1000lm
FACTOR 0.70Hdown 0.00mHwork 0.80m
Ework(AVE) 100lxρ (%) cc w fc
70 50 3050 30 20
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 4 Of 12
WEC AND CCEC
cc w fc
ρ
ρ
ρ
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.304
.288
.268
.247
.229
.213
.198
.185
.174
.163
.173
.158
.142
.129
.117
.107
.098
.090
.084
.078
.055
.048
.043
.038
.034
.031
.028
.025
.023
.022
.297
.282
.262
.243
.225
.209
.195
.182
.171
.161
.169
.155
.140
.127
.115
.106
.097
.090
.083
.078
.054
.048
.042
.038
.034
.030
.028
.025
.023
.022
.283
.270
.252
.233
.217
.202
.188
.176
.166
.156
.163
.150
.136
.124
.113
.103
.095
.088
.082
.077
.052
.047
.041
.037
.033
.030
.027
.025
.023
.022
.271
.259
.242
.225
.209
.195
.182
.171
.161
.152
.156
.146
.133
.121
.110
.101
.093
.087
.081
.075
.050
.046
.041
.036
.033
.030
.027
.025
.023
.021
.260
.249
.233
.217
.202
.189
.177
.166
.156
.148
.151
.141
.129
.118
.108
.099
.092
.085
.079
.074
.049
.044
.040
.036
.032
.029
.027
.025
.023
.021
cc w fc
ρ
ρ
ρ
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.190
.180
.172
.164
.156
.149
.142
.135
.129
.123
.117
.190
.156
.132
.114
.101
.091
.082
.075
.069
.065
.060
.190
.135
.098
.075
.059
.047
.039
.033
.029
.025
.022
.163
.154
.147
.141
.134
.128
.122
.116
.111
.106
.101
.163
.134
.114
.099
.087
.078
.071
.065
.060
.056
.052
.163
.116
.085
.065
.051
.041
.034
.029
.025
.022
.020
.111
.105
.101
.097
.092
.088
.084
.080
.077
.073
.070
.111
.092
.079
.068
.061
.055
.050
.046
.042
.039
.037
.111
.080
.059
.045
.036
.029
.024
.021
.018
.016
.014
.064
.061
.058
.056
.053
.051
.049
.047
.045
.043
.041
.064
.053
.046
.040
.036
.032
.029
.027
.025
.023
.022
.064
.047
.035
.027
.021
.017
.014
.012
.011
.009
.008
.020
.019
.019
.018
.017
.016
.016
.015
.014
.014
.013
.020
.017
.015
.013
.012
.010
.010
.009
.008
.008
.007
.020
.015
.011
.009
.007
.006
.005
.004
.004
.003
.003
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 5 Of 12
Uncorrected UGR Table
ceiling/cavitywalls
working planeRoom dimensions Viewed crosswise Viewed endwise
0.7 0.70.5 0.50.2 0.2
0.7 0.70.3 0.30.2 0.2
0.5 0.50.5 0.50.2 0.2
0.5 0.50.3 0.30.2 0.2
0.3 0.30.3 0.30.2 0.2
x = 2H y = 2H 3H 4H 6H 8H 12H
4H 2H 3H 4H 6H 8H 12H
8H 4H 6H 8H 12H
12H 4H 6H 8H
16.7 17.4 18.2 18.9 17.0 17.7 18.4 19.1 18.6 19.3 18.1 19.0 19.5 20.4 18.4 19.3 19.7 20.6 20.0 20.9 18.6 19.7 19.9 21.0 18.9 20.0 20.2 21.2 20.4 21.5 18.9 20.1 20.2 21.4 19.3 20.5 20.4 21.7 20.7 21.9 19.0 20.3 20.2 21.5 19.3 20.6 20.5 21.8 20.8 22.1 19.0 20.4 20.2 21.5 19.3 20.7 20.4 21.8 20.8 22.1
17.4 17.9 18.7 19.3 17.7 18.3 19.0 19.5 19.2 19.8 19.0 19.7 20.1 20.9 19.3 20.1 20.4 21.2 20.7 21.5 19.6 20.5 20.7 21.6 20.0 20.9 21.0 21.9 21.3 22.2 20.0 21.1 21.0 22.1 20.4 21.5 21.3 22.4 21.7 22.8 20.1 21.4 21.0 22.2 20.6 21.8 21.4 22.6 21.8 23.0 20.2 21.5 21.0 22.3 20.6 21.9 21.4 22.7 21.8 23.1
19.9 20.7 20.8 21.6 20.3 21.1 21.2 22.0 21.6 22.4 20.5 21.5 21.2 22.2 20.9 21.9 21.6 22.6 22.1 23.1 20.7 21.8 21.3 22.5 21.1 22.3 21.7 22.9 22.2 23.3 20.8 22.0 21.3 22.6 21.2 22.5 21.8 23.0 22.2 23.5
20.0 20.7 20.8 21.5 20.4 21.2 21.1 21.9 21.6 22.3 20.6 21.5 21.2 22.2 21.0 22.0 21.6 22.6 22.1 23.1 20.8 21.9 21.3 22.4 21.3 22.4 21.8 22.9 22.3 23.4
Variations with the observer position at spacings:S = 1.0H + 0.2 / - 0.2 + 0.1 / - 0.2 1.5H + 0.2 / - 0.4 + 0.2 / - 0.3 2.0H + 0.2 / - 0.3 + 0.2 / - 0.3
CIE Pub.117 Corrected 1454 lm Total Lamp Luminous Flux.(8log(F/F0) = 1.3)
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 58 46 39 57 46 39 56 45 39 33
0.80 68 56 49 67 56 49 65 55 48 42
1.00 76 65 58 75 65 58 73 66 57 50
1.25 83 73 66 82 72 66 79 71 65 58
1.50 88 79 72 87 78 71 84 76 70 63
2.00 95 87 81 93 86 80 90 83 78 70
2.50 99 92 86 97 90 85 93 87 83 75
3.00 103 96 90 100 94 89 96 91 87 79
4.00 107 101 96 104 99 95 100 96 92 83
5.00 109 104 100 106 102 99 102 99 96 86
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 7 Of 12
ISOCANDELA DIAGRAM
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90HORIZONTAL(DEG)
VERT
ICAL
(DEG
)
Imax:505.2(H0.0,V0.0) (At:C=0.0,Gamma=0.0)
UNIT: cd
10% 50.5220% 101.030% 151.640% 202.150% 252.660% 303.170% 353.780% 404.290% 454.7
MAX = 505.25 MIN = 240.00 AVG = 417.77 AVG/MAX = 0.83MIN/MAX = 0.48
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 8 Of 12
AAI Figure
1m3.281ft
287.07cm9.418ft
159.1,505.2lx14.78,46.94fc
2m6.562ft
574.13cm18.84ft
39.77,126.3lx3.695,11.73fc
3m9.843ft
861.20cm28.25ft
17.68,56.14lx1.642,5.215fc
4m13.12ft
1148.26cm37.67ft
9.943,31.58lx0.9237,2.934fc
5m16.4ft
1435.33cm47.09ft
6.363,20.21lx0.5912,1.878fc
Height Eavg,Emax DiameterAngle:110.27deg
Flux out:1058 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 9 Of 12
ISOLUX DIAGRAM
131.2' 40.00m
105.0' 32.00m
32.00m
105.0'
78.7' 24.00m
52.5' 16.00m
16.00m
52.5'
26.2' 8.00m
0.0' 0.00m
0.00m
0.0'
26.2' 8.00m
52.5' 16.00m
16.00m
52.5'
78.7' 24.00m
105.0' 32.00m
32.00m
105.0'
131.2' 40.00m
MOUNTING HEIGHT: 33'(10.0m)
3% 0.1514lx 0.01407fc 5% 0.2524lx 0.02345fc 10% 0.5048lx 0.0469fc 30% 1.514lx 0.1407fc 50% 2.524lx 0.2345fc 60% 3.029lx 0.2814fc 70% 3.534lx 0.3283fc 80% 4.038lx 0.3752fc 90% 4.543lx 0.4221fc
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 10 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 1454.34 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.148 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
297260 284865 269470 249275 220880 177885 1028
103008288927452546227518661202
203061294828052621236419791413
303124301628832709246821091584
403196309429672805257622451827
503270317330522895268023782007
603339324631312979277724921997
703389330331943050285625821733
803424334032333096291526541555
903439335632503115293626791495
1003433334932453110293226741575
1103404331832113071288426241777
1203354326531533010281725512073
1303289319830822934272924482106
1403220312330052848263323231935
1503153304929232761253121941706
1603094298328482672242920661533
1703043292827892605234019451302
1803008288927422547227318641101
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories
CIBSECategory
Gamma(deg)
Average Luminancemaximum
calculatedspecifiedmaximum
Patch Luminancemaximummeasured
specifiedmaximum
Category 1Category 2Category 3
55 to 9065 to 9075 to 90
343932502936
200200200
---------
500500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 11 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 1454.34 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.148 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
297260 284865 269470 249275 220880 177885 1028
103008288927452546227518661202
203061294828052621236419791413
303124301628832709246821091584
403196309429672805257622451827
503270317330522895268023782007
603339324631312979277724921997
703389330331943050285625821733
803424334032333096291526541555
903439335632503115293626791495
1003433334932453110293226741575
1103404331832113071288426241777
1203354326531533010281725512073
1303289319830822934272924482106
1403220312330052848263323231935
1503153304929232761253121941706
1603094298328482672242920661533
1703043292827892605234019451302
1803008288927422547227318641101
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits
Average Luminance(cd/sq.m)Maximum limit for screen type & software category usedrange
(deg)
55 to 9065 to 90
Maximummeasured
34393250
Type I,II screenSome neg.s'ware
10001000
Type I,II screenOnly pos.s'ware
15001500
Type III screenSome neg.s'ware
200200
Type III screenOnly pos.s'ware
500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25Distance(m)
0
0.55
1.1
1.65
2.2
2.75
3.3
3.85
4.4
4.95
5.5E(lx) MH = 10 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.6DEG Humidity:60%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-12 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME: LED Panel Light
DIM.:
MFR.: Light Green International Co.,Ltd
TYPE:natrual white
SPEC.:
SUR.:1.164*0.265
WEIGHT:5KGTest:U:228.8V I:0.3230A P:38.30W PF:0.5180 Lamp Flux:2278.36x1 lm
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,111.0°
UNIT:cd
C30/210,110.8°
UNIT:cd
C60/240,111.6°
UNIT:cd
C90/270,111.9°AVERAGE BEAM ANGLE(50%):111.3 DEG
0
170
340
510
680
850
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)
8
10
13
15
18
20
23
25
28
0.0 10.5 21.0S(m)20.0
16.013.09.806.50
3.302.601.601.30
0.9800
DATA OF LAMP PHOTOMETRIC DATA Eff: 59.49 lm/WMODELNOMINAL POWER(W)RATED VOLTAGE(V)NOMINAL FLUX(lm)LAMPS INSIDETEST VOLTAGE(V)
Imax(cd)LOR(%)TOTAL FLUX(lm)CIE CLASS up(%) down(%)η
η
S/MH(C0/180)S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360)CIBSE SHR NOMCIBSE SHR MAX
η
η
LGI-C0312WBA-Q382302278.361229.0
813.9100.02278.4DIRECT0.0100.0
1.251.300.0,52.20.0,47.81.251.35
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000] Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 2 Of 12
ZONAL FLUX DIAGRAMAND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM:
γ 5 0- 5 10 5- 10 15 10- 15 20 15- 20 25 20- 25 30 25- 30 35 30- 35 40 35- 40 45 40- 45 50 45- 50 55 50- 55 60 55- 60 65 60- 65 70 65- 70 75 70- 75 80 75- 80 85 80- 85 90 85- 90 95 90- 95 100 95-100 105 100-105 110 105-110 115 110-115 120 115-120 125 120-125 130 125-130 135 130-135 140 135-140 145 140-145 150 145-150 155 150-155 160 155-160 165 160-165 170 165-170 175 170-175 180 175-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp γ Φ Φ
DEG LUMINOUS INTENSITY:cd UNIT:lm
810.2 809.9 811.0 810.2 810.6 806.2 805.3 805.9 19.38 19.38 0.85,0.85799.4 802.4 808.0 802.9 799.9 794.8 796.7 794.5 57.51 76.89 3.37,3.37781.7 789.5 793.1 790.2 782.4 777.9 775.2 777.5 93.84 170.7 7.49,7.49756.7 766.1 778.1 767.1 757.5 750.2 753.7 749.4 127.1 297.8 13.1,13.1725.0 739.3 748.0 740.5 726.2 717.0 716.1 718.0 156.1 453.9 19.9,19.9686.3 703.2 717.8 703.0 685.2 676.3 678.4 677.0 179.4 633.3 27.8,27.8641.4 659.6 673.9 660.4 640.4 628.7 627.7 628.6 196.7 830.0 36.4,36.4591.3 612.7 629.9 614.3 589.8 578.1 576.9 577.3 206.9 1037 45.5,45.5536.0 556.8 573.6 558.4 534.4 518.4 515.4 517.7 210.0 1247 54.7,54.7476.9 500.5 517.2 502.3 474.6 458.8 454.0 458.0 205.6 1452 63.8,63.8414.4 436.4 451.9 437.6 411.8 391.9 385.9 391.1 194.4 1647 72.3,72.3349.4 372.5 386.7 373.1 346.3 325.3 317.9 324.6 176.4 1823 80,80281.2 303.5 316.6 304.0 278.9 255.2 247.0 254.4 152.8 1976 86.7,86.7213.2 234.5 246.5 234.9 210.0 186.0 176.2 185.1 124.1 2100 92.2,92.2145.4 165.0 176.7 165.3 141.6 117.5 113.3 116.9 92.12 2192 96.2,96.279.63 99.58 106.8 99.50 75.81 60.28 50.36 60.00 58.95 2251 98.8,98.819.86 25.59 0 25.47 16.39 11.67 0 11.61 25.13 2276 99.9,99.92.652 0 0 0 0.7370 0 0 0 2.008 2278 100,100
LUMINANCE LIMITATION CURVESGLARE CLASS ILLUMINANCE (lx)1.15 A 2000 1000 500 <=3001.50 B 2000 1000 500 <=3001.85 C 2000 1000 500 <=3002.20 D 2000 1000 500 <=3002.55 E 2000 1000 500 <=300
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 4 1
2
3468
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)G(DEG) C0/180 C90/27085 739 080 1486 199475 1821 221370 2021 233665 2157 242860 2265 250755 2342 255450 2405 260845 2457 2629
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
cc w fc
ρ
ρ
ρ
RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
1.191.04.91.80.71.63.57.52.47.43.40
1.191.00.84.72.62.54.48.43.39.35.32
1.19.96.79.65.55.48.42.37.33.29.27
1.161.02.89.78.70.62.56.51.46.43.39
1.16.98.83.71.61.54.48.43.38.35.32
1.16.95.78.65.55.47.41.37.33.29.27
1.11.98.86.75.67.60.54.49.45.41.38
1.11.95.80.69.60.53.47.42.38.34.31
1.11.92.76.64.54.47.41.36.32.29.27
1.06.94.82.73.65.58.53.48.44.40.37
1.06.91.78.67.59.52.46.41.37.34.31
1.06.89.74.63.54.46.41.36.32.29.26
1.02.90.79.70.63.56.51.46.43.39.37
1.02.88.76.65.57.50.45.40.37.33.31
1.02.86.73.61.53.46.40.36.32.29.26
1.00.84.70.59.51.44.38.34.30.27.25
AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k2
3
4
56789
10
20
30
40
50LAMPS LUMINAIRE BUDGETARY DIAGRAM
2
3
4
H=5H=5
55
66
77
H=8H=8
CONDITIONSFLUX 1000lm
FACTOR 0.70Hdown 0.00mHwork 0.80m
Ework(AVE) 100lxρ (%) cc w fc
70 50 3050 30 20
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 4 Of 12
WEC AND CCEC
cc w fc
ρ
ρ
ρ
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.300
.286
.266
.246
.228
.212
.198
.185
.173
.163
.171
.157
.142
.128
.116
.106
.098
.090
.084
.078
.054
.048
.042
.038
.034
.030
.028
.025
.023
.022
.293
.280
.261
.242
.224
.208
.194
.182
.170
.160
.167
.154
.140
.126
.115
.105
.097
.089
.083
.078
.053
.047
.042
.037
.033
.030
.028
.025
.023
.022
.280
.268
.250
.232
.216
.201
.188
.176
.165
.156
.161
.149
.136
.123
.112
.103
.095
.088
.082
.076
.051
.046
.041
.037
.033
.030
.027
.025
.023
.021
.268
.257
.241
.224
.208
.194
.182
.170
.160
.151
.154
.144
.132
.120
.110
.101
.093
.086
.080
.075
.050
.045
.040
.036
.033
.030
.027
.025
.023
.021
.257
.247
.232
.216
.201
.188
.176
.165
.156
.147
.149
.140
.128
.117
.108
.099
.091
.085
.079
.074
.048
.044
.040
.036
.032
.029
.027
.025
.023
.021
cc w fc
ρ
ρ
ρ
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.190
.180
.171
.164
.156
.149
.142
.135
.129
.122
.117
.190
.156
.132
.114
.101
.091
.082
.075
.069
.064
.060
.190
.135
.099
.075
.059
.047
.039
.033
.029
.025
.022
.163
.154
.147
.140
.134
.128
.122
.116
.111
.106
.101
.163
.134
.114
.099
.087
.078
.071
.065
.060
.056
.052
.163
.116
.085
.065
.051
.041
.034
.029
.025
.022
.020
.111
.105
.101
.096
.092
.088
.084
.080
.077
.073
.070
.111
.092
.079
.068
.061
.055
.050
.046
.042
.039
.037
.111
.080
.060
.046
.036
.029
.024
.021
.018
.016
.014
.064
.061
.058
.056
.053
.051
.049
.047
.045
.043
.041
.064
.053
.046
.040
.036
.032
.029
.027
.025
.023
.022
.064
.047
.035
.027
.021
.017
.014
.012
.011
.009
.008
.020
.019
.019
.018
.017
.016
.016
.015
.014
.014
.013
.020
.017
.015
.013
.012
.010
.010
.009
.008
.008
.007
.020
.015
.011
.009
.007
.006
.005
.004
.004
.003
.003
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 5 Of 12
Uncorrected UGR Table
ceiling/cavitywalls
working planeRoom dimensions Viewed crosswise Viewed endwise
0.7 0.70.5 0.50.2 0.2
0.7 0.70.3 0.30.2 0.2
0.5 0.50.5 0.50.2 0.2
0.5 0.50.3 0.30.2 0.2
0.3 0.30.3 0.30.2 0.2
x = 2H y = 2H 3H 4H 6H 8H 12H
4H 2H 3H 4H 6H 8H 12H
8H 4H 6H 8H 12H
12H 4H 6H 8H
16.0 16.4 17.5 17.9 16.2 16.7 17.7 18.1 17.9 18.3 17.4 18.0 18.8 19.4 17.7 18.3 19.1 19.6 19.3 19.9 18.0 18.7 19.3 20.0 18.3 19.0 19.6 20.2 19.8 20.5 18.3 19.1 19.6 20.4 18.7 19.5 19.8 20.7 20.1 20.9 18.4 19.2 19.6 20.4 18.7 19.6 19.9 20.7 20.2 21.0 18.4 19.2 19.5 20.4 18.7 19.6 19.8 20.7 20.1 21.0
16.7 17.0 18.0 18.3 17.0 17.3 18.2 18.6 18.5 18.8 18.3 18.8 19.5 19.9 18.7 19.1 19.8 20.2 20.1 20.5 19.0 19.6 20.0 20.6 19.4 19.9 20.4 20.9 20.7 21.3 19.4 20.2 20.4 21.1 19.8 20.6 20.7 21.5 21.1 21.8 19.5 20.3 20.4 21.2 20.0 20.7 20.8 21.6 21.2 21.9 19.6 20.3 20.4 21.1 20.0 20.7 20.8 21.5 21.2 21.9
19.3 19.8 20.2 20.7 19.7 20.2 20.5 21.1 20.9 21.4 19.9 20.6 20.6 21.3 20.4 21.0 21.0 21.7 21.5 22.1 20.1 20.8 20.7 21.4 20.6 21.2 21.2 21.8 21.6 22.3 20.2 20.8 20.7 21.3 20.7 21.3 21.2 21.8 21.7 22.3
19.3 19.8 20.1 20.6 19.7 20.3 20.5 21.0 20.9 21.4 20.0 20.6 20.6 21.3 20.4 21.1 21.0 21.7 21.5 22.1 20.2 20.9 20.8 21.4 20.7 21.3 21.2 21.8 21.7 22.3
Variations with the observer position at spacings:S = 1.0H + 0.2 / - 0.2 + 0.1 / - 0.2 1.5H + 0.2 / - 0.3 + 0.2 / - 0.3 2.0H + 0.2 / - 0.3 + 0.2 / - 0.3
CIE Pub.117 Corrected 2278 lm Total Lamp Luminous Flux.(8log(F/F0) = 2.9)
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 NA NA NA NA NA NA NA NA NA NA
0.80 NA NA NA NA NA NA NA NA NA NA
1.00 83 74 68 82 73 67 80 74 67 61
1.25 89 80 74 88 80 74 86 78 73 67
1.50 94 86 80 93 85 80 90 83 79 72
2.00 100 92 87 98 91 86 95 89 85 78
2.50 103 96 91 101 95 90 97 92 88 81
3.00 105 100 95 103 98 94 99 95 92 84
4.00 108 103 99 106 102 98 102 98 95 87
5.00 110 106 102 108 104 101 103 100 98 89
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 2.00Suspended
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 7 Of 12
ISOCANDELA DIAGRAM
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90HORIZONTAL(DEG)
VERT
ICAL
(DEG
)
Imax:813.9(H0.0,V0.0) (At:C=0.0,Gamma=0.0)
UNIT: cd
10% 81.3920% 162.830% 244.240% 325.650% 407.060% 488.370% 569.780% 651.190% 732.5
MAX = 813.90 MIN = 385.39 AVG = 660.79 AVG/MAX = 0.81MIN/MAX = 0.47
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 8 Of 12
AAI Figure
1m3.281ft
290.73cm9.538ft
250.4,813.9lx23.26,75.61fc
2m6.562ft
581.46cm19.08ft
62.60,203.5lx5.816,18.90fc
3m9.843ft
872.18cm28.61ft
27.82,90.43lx2.585,8.402fc
4m13.12ft
1162.91cm38.15ft
15.65,50.87lx1.454,4.726fc
5m16.4ft
1453.64cm47.69ft
10.02,32.56lx0.9305,3.025fc
Height Eavg,Emax DiameterAngle:110.95deg
Flux out:1665 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 9 Of 12
ISOLUX DIAGRAM
65.6' 20.00m
52.5' 16.00m
16.00m
52.5'
39.4' 12.00m
26.2' 8.00m
8.00m
26.2'
13.1' 4.00m
0.0' 0.00m
0.00m
0.0'
13.1' 4.00m
26.2' 8.00m
8.00m
26.2'
39.4' 12.00m
52.5' 16.00m
16.00m
52.5'
65.6' 20.00m
MOUNTING HEIGHT: 16'(5.0m)
3% 0.9767lx 0.09074fc 5% 1.628lx 0.1512fc 10% 3.256lx 0.3025fc 30% 9.767lx 0.9074fc 50% 16.28lx 1.512fc
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 10 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 2278.36 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.3085 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
234260 226565 215770 202175 182180 148685 739
10235222802185204718571504951
202382231722182098192616461245
302412235422652149198517331340
402451239123082203203918261101
50248624272351224220951886795
60251924552384228021471932488
70253524812406230821811962230
8025492499242223292205198760
902554250724282336221319940
10025502502242423322207198760
110253924852411231521851961229
120252424602390228521501929487
130249224312356224721001887793
1402459239623112207204218241094
1502419236122672149198417281326
1602384232022212096191416371232
170235422782185204018411472901
180232722452139199117731415610
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories
CIBSECategory
Gamma(deg)
Average Luminancemaximum
calculatedspecifiedmaximum
Patch Luminancemaximummeasured
specifiedmaximum
Category 1Category 2Category 3
55 to 9065 to 9075 to 90
255424282213
500500500
100020003000
150015001500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 11 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 2278.36 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.3085 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
234260 226565 215770 202175 182180 148685 739
10235222802185204718571504951
202382231722182098192616461245
302412235422652149198517331340
402451239123082203203918261101
50248624272351224220951886795
60251924552384228021471932488
70253524812406230821811962230
8025492499242223292205198760
902554250724282336221319940
10025502502242423322207198760
110253924852411231521851961229
120252424602390228521501929487
130249224312356224721001887793
1402459239623112207204218241094
1502419236122672149198417281326
1602384232022212096191416371232
170235422782185204018411472901
180232722452139199117731415610
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits
Average Luminance(cd/sq.m)Maximum limit for screen type & software category usedrange
(deg)
55 to 9065 to 90
Maximummeasured
25542428
Type I,II screenSome neg.s'ware
10001000
Type I,II screenOnly pos.s'ware
15001500
Type III screenSome neg.s'ware
200200
Type III screenOnly pos.s'ware
500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25Distance(m)
0
3.5
7
10.5
14
17.5
21
24.5
28
31.5
35E(lx) MH = 5 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:20.8DEG Humidity:36%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2011-01-11 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME: LED Panel Light
DIM.:
MFR.: Light-green
TYPE:cool white
SPEC.:
SUR.:0.563m*0.563m
WEIGHT:5KGTest:U:229.1V I:0.3240A P:38.70W PF:0.5200 Lamp Flux:2197.17x1 lm
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,111.1°
UNIT:cd
C30/210,112.5°
UNIT:cd
C60/240,115.3°
UNIT:cd
C90/270,116.6°AVERAGE BEAM ANGLE(50%):113.9 DEG
0
160
320
480
640
800
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)
14
18
22
26
30
34
38
42
46
0.0 17.0 34.0S(m)4.50
3.803.002.301.50
0.76000.61000.38000.30000.2300
DATA OF LAMP PHOTOMETRIC DATA Eff: 56.77 lm/WMODELNOMINAL POWER(W)RATED VOLTAGE(V)NOMINAL FLUX(lm)LAMPS INSIDETEST VOLTAGE(V)
Imax(cd)LOR(%)TOTAL FLUX(lm)CIE CLASS up(%) down(%)η
η
S/MH(C0/180)S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360)CIBSE SHR NOMCIBSE SHR MAX
η
η
LGI-C0606WDA-Q402302197.171229.2
756.9100.02197.2DIRECT0.0100.0
1.271.340.0,50.60.0,49.41.251.35
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000] Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 2 Of 12
ZONAL FLUX DIAGRAMAND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM:
γ 5 0- 5 10 5- 10 15 10- 15 20 15- 20 25 20- 25 30 25- 30 35 30- 35 40 35- 40 45 40- 45 50 45- 50 55 50- 55 60 55- 60 65 60- 65 70 65- 70 75 70- 75 80 75- 80 85 80- 85 90 85- 90 95 90- 95 100 95-100 105 100-105 110 105-110 115 110-115 120 115-120 125 120-125 130 125-130 135 130-135 140 135-140 145 140-145 150 145-150 155 150-155 160 155-160 165 160-165 170 165-170 175 170-175 180 175-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp γ Φ Φ
DEG LUMINOUS INTENSITY:cd UNIT:lm
754.0 754.5 755.4 754.6 754.0 754.4 755.0 754.3 18.06 18.06 0.82,0.82745.4 747.9 751.0 747.9 745.5 747.2 749.7 747.0 53.73 71.80 3.27,3.27730.9 736.7 742.6 736.6 731.2 734.9 738.9 734.5 87.99 159.8 7.27,7.27708.9 719.7 730.6 719.2 710.3 715.6 723.7 715.6 119.8 279.6 12.7,12.7680.8 695.5 709.9 696.0 682.4 690.3 698.6 689.0 148.0 427.6 19.5,19.5645.7 664.4 683.7 665.3 647.3 657.2 668.3 655.3 171.3 598.9 27.3,27.3603.9 626.3 647.4 626.9 605.4 616.6 628.6 614.8 188.8 787.7 35.8,35.8556.0 581.0 604.4 581.5 557.2 569.5 583.0 567.8 199.5 987.2 44.9,44.9502.6 528.7 552.1 529.1 504.0 516.3 529.6 514.6 203.1 1190 54.2,54.2445.0 471.8 494.6 471.9 446.4 459.0 472.2 457.4 199.3 1390 63.2,63.2384.0 409.7 431.1 410.0 386.0 397.5 411.6 395.6 188.6 1578 71.8,71.8321.1 345.3 364.8 345.5 322.9 333.9 349.6 331.9 171.5 1750 79.6,79.6256.9 278.5 295.7 279.2 258.9 269.6 277.0 266.9 148.8 1898 86.4,86.4192.4 211.1 225.9 212.0 194.4 203.0 206.7 199.3 121.0 2020 91.9,91.9129.1 144.5 156.7 145.7 130.8 135.8 137.4 132.0 89.92 2109 96,9670.02 82.02 90.80 83.34 71.24 73.78 71.75 70.13 57.45 2167 98.6,98.621.69 31.13 23.26 32.22 21.81 25.23 16.22 23.04 27.12 2194 99.9,99.92.057 0 0 0 0.7576 0 0 0 3.172 2197 100,100
LUMINANCE LIMITATION CURVESGLARE CLASS ILLUMINANCE (lx)1.15 A 2000 1000 500 <=3001.50 B 2000 1000 500 <=3001.85 C 2000 1000 500 <=3002.20 D 2000 1000 500 <=3002.55 E 2000 1000 500 <=300
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 4 1
2
3468
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)G(DEG) C0/180 C90/27085 785 84280 1272 165075 1573 191070 1774 208365 1917 220760 2026 230155 2112 237150 2184 242745 2242 2463
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
cc w fc
ρ
ρ
ρ
RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio
80%50% 30% 10%
30%
70%50% 30% 10%
30%
50%50% 30% 10%
30%
30%50% 30% 10%
30%
10%50% 30% 10%
30%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
1.321.13.97.84.74.65.59.53.48.44.40
1.321.08.89.75.64.55.49.43.39.35.32
1.321.03.82.67.56.48.42.37.33.29.27
1.271.09.94.82.72.64.57.52.47.43.40
1.271.04.87.73.63.55.48.43.39.35.32
1.271.00.81.66.56.48.42.37.33.29.26
1.181.02.89.78.69.61.55.50.46.42.39
1.18.99.83.71.61.53.47.42.38.34.31
1.18.95.78.65.55.47.41.36.32.29.26
1.10.97.84.74.66.59.53.48.44.41.38
1.10.94.79.68.59.52.46.41.37.34.31
1.10.91.75.63.54.46.41.36.32.29.26
1.03.91.80.71.63.57.51.47.43.40.37
1.03.89.76.66.57.51.45.40.37.33.30
1.03.87.73.61.53.46.40.36.32.29.26
1.00.84.70.59.50.43.38.33.30.27.24
AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k2
3
4
56789
10
20
30
40
50LAMPS LUMINAIRE BUDGETARY DIAGRAM
2
3
4
H=5H=5
55
66
77
H=8H=8
CONDITIONSFLUX 1000lm
FACTOR 0.70Hdown 0.00mHwork 0.80m
Ework(AVE) 100lxρ (%) cc w fc
70 50 3050 30 20
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 4 Of 12
WEC AND CCEC
cc w fc
ρ
ρ
ρ
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%50% 30% 10%
30%
70%50% 30% 10%
30%
50%50% 30% 10%
30%
30%50% 30% 10%
30%
10%50% 30% 10%
30%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.355
.327
.298
.271
.248
.228
.211
.196
.183
.171
.201
.178
.157
.139
.125
.113
.103
.095
.088
.081
.063
.054
.047
.041
.036
.032
.029
.026
.024
.022
.343
.317
.290
.265
.243
.224
.207
.192
.180
.168
.194
.173
.154
.137
.123
.112
.102
.094
.087
.081
.061
.053
.046
.040
.036
.032
.029
.026
.024
.022
.320
.299
.275
.252
.232
.215
.199
.186
.174
.163
.183
.165
.148
.133
.120
.109
.100
.092
.085
.079
.058
.051
.045
.039
.035
.032
.029
.026
.024
.022
.301
.283
.262
.241
.223
.206
.192
.179
.168
.158
.173
.158
.143
.129
.117
.106
.098
.090
.084
.078
.055
.049
.043
.039
.034
.031
.028
.026
.024
.022
.283
.269
.250
.231
.214
.198
.185
.173
.163
.153
.164
.152
.138
.125
.114
.104
.096
.088
.082
.077
.053
.048
.042
.038
.034
.031
.028
.026
.024
.022
cc w fc
ρ
ρ
ρ
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%50% 30% 10%
30%
70%50% 30% 10%
30%
50%50% 30% 10%
30%
30%50% 30% 10%
30%
10%50% 30% 10%
30%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.316
.273
.242
.217
.198
.181
.168
.156
.146
.137
.129
.316
.241
.191
.156
.132
.114
.100
.089
.080
.073
.067
.316
.213
.149
.109
.083
.065
.052
.043
.036
.031
.027
.266
.231
.205
.185
.169
.155
.144
.134
.125
.118
.111
.266
.205
.163
.134
.114
.098
.086
.077
.070
.064
.059
.266
.181
.128
.094
.072
.056
.045
.038
.032
.027
.024
.176
.155
.138
.125
.115
.106
.099
.092
.086
.081
.077
.176
.138
.111
.092
.079
.068
.060
.054
.049
.045
.041
.176
.123
.088
.065
.050
.040
.032
.027
.022
.019
.017
.099
.087
.079
.072
.066
.061
.057
.053
.050
.047
.045
.099
.079
.064
.053
.046
.040
.035
.032
.029
.026
.024
.099
.071
.051
.038
.030
.023
.019
.016
.013
.011
.010
.031
.028
.025
.023
.021
.020
.018
.017
.016
.015
.014
.031
.025
.020
.017
.015
.013
.011
.010
.009
.009
.008
.031
.022
.017
.012
.010
.008
.006
.005
.004
.004
.003
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 5 Of 12
Uncorrected UGR Table
ceiling/cavitywalls
working planeRoom dimensions Viewed crosswise Viewed endwise
0.7 0.70.5 0.50.2 0.2
0.7 0.70.3 0.30.2 0.2
0.5 0.50.5 0.50.2 0.2
0.5 0.50.3 0.30.2 0.2
0.3 0.30.3 0.30.2 0.2
x = 2H y = 2H 3H 4H 6H 8H 12H
4H 2H 3H 4H 6H 8H 12H
8H 4H 6H 8H 12H
12H 4H 6H 8H
15.5 16.0 17.0 17.6 15.7 16.3 17.2 17.8 17.4 18.0 16.9 17.6 18.3 19.0 17.2 17.9 18.5 19.2 18.7 19.4 17.4 18.2 18.7 19.5 17.7 18.5 19.0 19.8 19.2 20.0 17.7 18.6 18.9 19.8 18.0 18.9 19.2 20.1 19.5 20.4 17.7 18.7 18.9 19.9 18.1 19.0 19.2 20.2 19.5 20.5 17.7 18.7 18.9 19.9 18.1 19.1 19.2 20.2 19.5 20.5
16.1 16.6 17.5 17.9 16.5 16.9 17.7 18.2 18.0 18.4 17.7 18.3 18.9 19.5 18.1 18.7 19.2 19.8 19.5 20.1 18.3 19.0 19.4 20.1 18.7 19.4 19.7 20.4 20.1 20.7 18.7 19.6 19.7 20.5 19.1 20.0 20.0 20.8 20.4 21.2 18.8 19.7 19.7 20.6 19.2 20.1 20.1 21.0 20.5 21.4 18.8 19.8 19.6 20.6 19.3 20.2 20.0 21.0 20.4 21.4
18.6 19.2 19.5 20.1 19.0 19.6 19.9 20.5 20.3 20.9 19.2 19.9 19.9 20.6 19.6 20.3 20.3 21.0 20.7 21.5 19.3 20.2 20.0 20.8 19.8 20.6 20.4 21.2 20.8 21.7 19.4 20.3 19.9 20.8 19.8 20.8 20.4 21.3 20.8 21.8
18.6 19.2 19.4 20.0 19.1 19.7 19.8 20.4 20.2 20.8 19.2 19.9 19.9 20.6 19.7 20.4 20.3 21.0 20.7 21.5 19.4 20.2 20.0 20.8 19.9 20.7 20.4 21.2 20.9 21.7
Variations with the observer position at spacings:S = 1.0H + 0.2 / - 0.2 + 0.2 / - 0.2 1.5H + 0.2 / - 0.3 + 0.2 / - 0.3 2.0H + 0.2 / - 0.3 + 0.2 / - 0.3
CIE Pub.117 Corrected 2197 lm Total Lamp Luminous Flux.(8log(F/F0) = 2.7)
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 58 46 39 57 46 39 56 45 39 32
0.80 68 56 49 67 56 49 65 55 48 41
1.00 76 65 58 75 65 58 73 66 57 50
1.25 83 73 66 82 72 65 79 71 65 57
1.50 88 79 72 87 78 71 84 76 70 63
2.00 95 87 80 93 86 80 90 83 78 70
2.50 99 92 86 97 90 85 93 87 83 75
3.00 103 96 90 100 94 89 96 91 87 79
4.00 107 101 96 104 99 95 100 96 92 83
5.00 109 104 100 106 102 99 102 99 96 86
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 7 Of 12
ISOCANDELA DIAGRAM
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90HORIZONTAL(DEG)
VERT
ICAL
(DEG
)
Imax:756.9(H-0.5,V0.0) (At:C=180.0,Gamma=0.5)
UNIT: cd
10% 75.6920% 151.430% 227.140% 302.850% 378.560% 454.170% 529.880% 605.590% 681.2
MAX = 756.92 MIN = 371.68 AVG = 629.64 AVG/MAX = 0.83MIN/MAX = 0.49
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 8 Of 12
AAI Figure
1m3.281ft
291.33cm9.558ft
233.7,756.9lx21.72,70.32fc
2m6.562ft
582.65cm19.12ft
58.43,189.2lx5.429,17.58fc
3m9.843ft
873.98cm28.67ft
25.97,84.10lx2.413,7.813fc
4m13.12ft
1165.30cm38.23ft
14.61,47.31lx1.357,4.395fc
5m16.4ft
1456.63cm47.79ft
9.350,30.28lx0.8686,2.813fc
Height Eavg,Emax DiameterAngle:111.06deg
Flux out:1614 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 9 Of 12
ISOLUX DIAGRAM
131.2' 40.00m
105.0' 32.00m
32.00m
105.0'
78.7' 24.00m
52.5' 16.00m
16.00m
52.5'
26.2' 8.00m
0.0' 0.00m
0.00m
0.0'
26.2' 8.00m
52.5' 16.00m
16.00m
52.5'
78.7' 24.00m
105.0' 32.00m
32.00m
105.0'
131.2' 40.00m
MOUNTING HEIGHT: 33'(10.0m)
3% 0.2269lx 0.02108fc 5% 0.3782lx 0.03513fc 10% 0.7564lx 0.07027fc 30% 2.269lx 0.2108fc 50% 3.782lx 0.3513fc
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 10 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 2197.17 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.317 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
211260 202665 191770 177475 157380 127285 785
10212520381934179015931244633
20215020691964182716341344894
30218821092006187216841402976
402231215420551924173614611088
502274220021021971178715221157
602314224021462017183515741130
70234322712178205318741613981
80236322932199207519011641879
90237123012207208319101650842
100236622962202207919061646883
110234822762182205518781621994
1202316224321472021184415891156
1302276220121061979179915441194
1402232215720611933175214871130
1502192211420151886170114291019
160215620761976184216531372939
170213220491946181016131234670
180212320371933179315941294789
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories
CIBSECategory
Gamma(deg)
Average Luminancemaximum
calculatedspecifiedmaximum
Patch Luminancemaximummeasured
specifiedmaximum
Category 1Category 2Category 3
55 to 9065 to 9075 to 90
237122071910
200200200
---------
500500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 11 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 2197.17 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.317 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
211260 202665 191770 177475 157380 127285 785
10212520381934179015931244633
20215020691964182716341344894
30218821092006187216841402976
402231215420551924173614611088
502274220021021971178715221157
602314224021462017183515741130
70234322712178205318741613981
80236322932199207519011641879
90237123012207208319101650842
100236622962202207919061646883
110234822762182205518781621994
1202316224321472021184415891156
1302276220121061979179915441194
1402232215720611933175214871130
1502192211420151886170114291019
160215620761976184216531372939
170213220491946181016131234670
180212320371933179315941294789
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits
Average Luminance(cd/sq.m)Maximum limit for screen type & software category usedrange
(deg)
55 to 9065 to 90
Maximummeasured
23712207
Type I,II screenSome neg.s'ware
10001000
Type I,II screenOnly pos.s'ware
15001500
Type III screenSome neg.s'ware
200200
Type III screenOnly pos.s'ware
500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25Distance(m)
0
0.8
1.6
2.4
3.2
4
4.8
5.6
6.4
7.2
8E(lx) MH = 10 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:24.6DEG Humidity:53%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME: LED Panel Light
DIM.:
MFR.: Light-green
TYPE:natural white
SPEC.:
SUR.:1.164m*0.265m
WEIGHT:5KGTest:U:230.1V I:0.5750A P:72.80W PF:0.5500 Lamp Flux:4112.89x1 lm
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,113.2°
UNIT:cd
C30/210,114.5°
UNIT:cd
C60/240,116.8°
UNIT:cd
C90/270,117.9°AVERAGE BEAM ANGLE(50%):115.6 DEG
0
300
600
900
1200
1500
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)
14
18
22
26
30
34
38
42
46
0.0 17.0 34.0S(m)8.30
6.905.604.202.80
1.401.10
0.69000.56000.4200
DATA OF LAMP PHOTOMETRIC DATA Eff: 56.50 lm/WMODELNOMINAL POWER(W)RATED VOLTAGE(V)NOMINAL FLUX(lm)LAMPS INSIDETEST VOLTAGE(V)
Imax(cd)LOR(%)TOTAL FLUX(lm)CIE CLASS up(%) down(%)η
η
S/MH(C0/180)S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360)CIBSE SHR NOMCIBSE SHR MAX
η
η
LGI-C0612WBA-Q762304112.891230.3
1390100.04112.9DIRECT0.0100.0
1.271.370.0,51.90.0,48.11.251.35
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000] Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 2 Of 12
ZONAL FLUX DIAGRAMAND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM:
γ 5 0- 5 10 5- 10 15 10- 15 20 15- 20 25 20- 25 30 25- 30 35 30- 35 40 35- 40 45 40- 45 50 45- 50 55 50- 55 60 55- 60 65 60- 65 70 65- 70 75 70- 75 80 75- 80 85 80- 85 90 85- 90 95 90- 95 100 95-100 105 100-105 110 105-110 115 110-115 120 115-120 125 120-125 130 125-130 135 130-135 140 135-140 145 140-145 150 145-150 155 150-155 160 155-160 165 160-165 170 165-170 175 170-175 180 175-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp γ Φ Φ
DEG LUMINOUS INTENSITY:cd UNIT:lm
1384 1387 1390 1388 1386 1384 1384 1383 33.18 33.18 0.81,0.811368 1377 1386 1380 1371 1370 1373 1368 98.72 131.9 3.21,3.211341 1359 1375 1363 1346 1348 1353 1344 161.8 293.7 7.14,7.141303 1332 1358 1336 1310 1314 1325 1309 220.6 514.3 12.5,12.51254 1294 1328 1298 1261 1267 1281 1262 273.1 787.4 19.1,19.11193 1243 1288 1248 1200 1208 1226 1202 317.2 1105 26.9,26.91120 1179 1229 1184 1128 1135 1153 1129 350.9 1456 35.4,35.41035 1102 1157 1107 1043 1049 1069 1043 372.4 1828 44.4,44.4941.0 1011 1067 1016 949.3 951.0 968.4 944.1 380.7 2209 53.7,53.7838.4 909.9 964.1 915.2 846.4 844.8 859.5 837.7 375.3 2584 62.8,62.8729.2 797.5 848.0 803.0 735.3 729.7 738.6 721.7 356.4 2940 71.5,71.5613.2 678.3 724.5 684.3 619.0 608.9 612.6 600.8 324.7 3265 79.4,79.4494.4 553.8 594.2 559.0 498.8 482.1 482.5 476.4 281.8 3547 86.2,86.2373.6 426.3 459.9 431.1 376.5 355.5 351.4 349.8 229.8 3777 91.8,91.8253.2 299.2 325.7 302.7 254.6 230.8 224.6 226.2 170.7 3947 96,96138.7 177.0 195.7 180.4 139.2 117.7 106.9 113.2 108.6 4056 98.6,98.638.97 73.78 52.77 76.89 35.45 33.06 20.02 31.16 50.88 4107 99.9,99.94.235 0 0 0 1.922 0 0 0 6.046 4113 100,100
LUMINANCE LIMITATION CURVESGLARE CLASS ILLUMINANCE (lx)1.15 A 2000 1000 500 <=3001.50 B 2000 1000 500 <=3001.85 C 2000 1000 500 <=3002.20 D 2000 1000 500 <=3002.55 E 2000 1000 500 <=300
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 4 1
2
3468
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)G(DEG) C0/180 C90/27085 1449 196380 2588 365375 3171 407970 3541 435865 3792 455760 3975 469755 4121 479250 4228 486245 4314 4890
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
cc w fc
ρ
ρ
ρ
RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
1.191.04.91.80.70.63.56.51.47.43.39
1.19.00.84.71.62.54.47.42.38.34.31
1.19.96.78.65.55.47.41.36.32.29.26
1.161.02.89.78.69.62.55.50.46.42.39
1.16.98.83.70.61.53.47.42.38.34.31
1.16.95.77.64.54.47.41.36.32.29.26
1.11.98.85.75.67.60.54.49.45.41.38
1.11.94.80.68.59.52.46.41.37.34.31
1.11.92.75.63.54.46.40.36.32.29.26
1.06.94.82.72.64.58.52.47.43.40.37
1.06.91.78.67.58.51.45.40.37.33.30
1.06.89.74.62.53.46.40.35.32.28.26
1.02.90.79.70.62.56.50.46.42.39.36
1.02.88.75.65.57.50.44.40.36.33.30
1.02.86.72.61.52.45.40.35.31.28.26
1.00.84.70.59.50.43.38.33.30.26.24
AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k2
3
4
56789
10
20
30
40
50LAMPS LUMINAIRE BUDGETARY DIAGRAM
2
3
4
H=5H=5
55
66
77
H=8H=8
CONDITIONSFLUX 1000lm
FACTOR 0.70Hdown 0.00mHwork 0.80m
Ework(AVE) 100lxρ (%) cc w fc
70 50 3050 30 20
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 4 Of 12
WEC AND CCEC
cc w fc
ρ
ρ
ρ
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.305
.289
.269
.249
.230
.214
.199
.186
.174
.164
.173
.159
.143
.129
.117
.107
.098
.091
.084
.079
.055
.049
.043
.038
.034
.031
.028
.026
.024
.022
.298
.283
.263
.244
.226
.210
.196
.183
.172
.161
.170
.156
.141
.128
.116
.106
.097
.090
.084
.078
.054
.048
.042
.038
.034
.031
.028
.025
.023
.022
.284
.271
.253
.235
.218
.203
.189
.177
.166
.157
.163
.151
.137
.124
.113
.104
.096
.088
.082
.077
.052
.047
.042
.037
.033
.030
.028
.025
.023
.022
.272
.261
.243
.226
.210
.196
.183
.172
.161
.152
.157
.146
.133
.121
.111
.102
.094
.087
.081
.076
.050
.046
.041
.037
.033
.030
.027
.025
.023
.022
.261
.251
.235
.218
.203
.190
.177
.167
.157
.148
.151
.142
.130
.119
.109
.100
.092
.085
.080
.075
.049
.045
.040
.036
.033
.030
.027
.025
.023
.021
cc w fc
ρ
ρ
ρ
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.190
.180
.172
.164
.157
.149
.142
.135
.129
.123
.117
.190
.156
.132
.114
.101
.091
.082
.075
.070
.065
.060
.190
.135
.098
.074
.058
.047
.039
.033
.029
.025
.022
.163
.154
.147
.141
.134
.128
.122
.117
.111
.106
.101
.163
.134
.114
.099
.087
.078
.071
.065
.060
.056
.052
.163
.116
.085
.065
.051
.041
.034
.029
.025
.022
.020
.111
.105
.101
.097
.092
.088
.084
.081
.077
.073
.070
.111
.092
.079
.068
.061
.055
.050
.046
.042
.039
.037
.111
.080
.059
.045
.036
.029
.024
.020
.018
.016
.014
.064
.061
.058
.056
.054
.051
.049
.047
.045
.043
.041
.064
.053
.046
.040
.036
.032
.029
.027
.025
.023
.022
.064
.047
.035
.027
.021
.017
.014
.012
.011
.009
.008
.020
.019
.019
.018
.017
.016
.016
.015
.014
.014
.013
.020
.017
.015
.013
.012
.010
.010
.009
.008
.008
.007
.020
.015
.011
.009
.007
.006
.005
.004
.003
.003
.003
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 5 Of 12
Uncorrected UGR Table
ceiling/cavitywalls
working planeRoom dimensions Viewed crosswise Viewed endwise
0.7 0.70.5 0.50.2 0.2
0.7 0.70.3 0.30.2 0.2
0.5 0.50.5 0.50.2 0.2
0.5 0.50.3 0.30.2 0.2
0.3 0.30.3 0.30.2 0.2
x = 2H y = 2H 3H 4H 6H 8H 12H
4H 2H 3H 4H 6H 8H 12H
8H 4H 6H 8H 12H
12H 4H 6H 8H
17.9 18.6 19.5 20.2 18.2 18.9 19.7 20.4 19.9 20.6 19.4 20.3 20.8 21.7 19.7 20.6 21.0 21.9 21.3 22.1 19.9 20.9 21.3 22.2 20.2 21.2 21.5 22.5 21.8 22.7 20.2 21.4 21.5 22.6 20.6 21.7 21.8 22.9 22.0 23.2 20.3 21.5 21.5 22.7 20.6 21.9 21.8 23.0 22.1 23.3 20.3 21.6 21.4 22.8 20.6 21.9 21.7 23.1 22.0 23.4
18.7 19.2 20.0 20.5 19.0 19.5 20.2 20.8 20.5 21.0 20.3 21.0 21.5 22.2 20.6 21.4 21.8 22.5 22.1 22.8 20.9 21.8 22.0 22.8 21.3 22.2 22.3 23.2 22.7 23.5 21.3 22.4 22.3 23.3 21.7 22.8 22.6 23.7 23.0 24.0 21.4 22.6 22.3 23.5 21.8 23.0 22.7 23.8 23.1 24.2 21.4 22.7 22.2 23.5 21.9 23.1 22.6 23.9 23.0 24.3
21.3 22.0 22.1 22.9 21.7 22.4 22.5 23.3 22.9 23.6 21.8 22.8 22.5 23.5 22.3 23.2 23.0 23.9 23.4 24.3 22.0 23.1 22.6 23.7 22.4 23.5 23.0 24.1 23.5 24.6 22.0 23.2 22.6 23.8 22.5 23.7 23.0 24.2 23.5 24.7
21.3 22.0 22.1 22.8 21.7 22.4 22.5 23.2 22.9 23.6 21.9 22.8 22.5 23.4 22.4 23.3 23.0 23.9 23.4 24.3 22.1 23.1 22.6 23.7 22.6 23.6 23.1 24.1 23.6 24.6
Variations with the observer position at spacings:S = 1.0H + 0.2 / - 0.2 + 0.1 / - 0.2 1.5H + 0.2 / - 0.3 + 0.2 / - 0.3 2.0H + 0.2 / - 0.3 + 0.2 / - 0.3
CIE Pub.117 Corrected 4113 lm Total Lamp Luminous Flux.(8log(F/F0) = 4.9)
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 57 46 39 57 45 39 55 45 38 32
0.80 67 56 48 66 55 48 65 55 48 41
1.00 76 65 58 75 64 57 73 66 57 50
1.25 83 73 66 82 72 65 79 71 64 57
1.50 88 78 71 87 77 71 84 76 70 62
2.00 95 87 80 93 85 79 90 83 78 70
2.50 99 91 85 97 90 84 93 87 83 74
3.00 102 96 90 100 94 89 96 91 87 78
4.00 106 101 96 104 99 95 100 96 92 83
5.00 109 104 100 106 102 99 102 99 95 86
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 7 Of 12
ISOCANDELA DIAGRAM
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90HORIZONTAL(DEG)
VERT
ICAL
(DEG
)
Imax:1390(H0.0,V-4.0) (At:C=90.0,Gamma=4.0)
UNIT: cd
10% 139.020% 278.030% 417.140% 556.150% 695.160% 834.170% 973.280% 111290% 1251
MAX = 1390.2 MIN = 689.22 AVG = 1165.3 AVG/MAX = 0.84MIN/MAX = 0.50
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 8 Of 12
AAI Figure
1m3.281ft
303.20cm9.947ft
412.8,1390lx38.35,129.1fc
2m6.562ft
606.39cm19.89ft
103.2,347.5lx9.587,32.28fc
3m9.843ft
909.59cm29.84ft
45.86,154.4lx4.261,14.35fc
4m13.12ft
1212.78cm39.79ft
25.80,86.87lx2.397,8.070fc
5m16.4ft
1515.98cm49.74ft
16.51,55.60lx1.534,5.165fc
Height Eavg,Emax DiameterAngle:113.18deg
Flux out:3075 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 9 Of 12
ISOLUX DIAGRAM
131.2' 40.00m
105.0' 32.00m
32.00m
105.0'
78.7' 24.00m
52.5' 16.00m
16.00m
52.5'
26.2' 8.00m
0.0' 0.00m
0.00m
0.0'
26.2' 8.00m
52.5' 16.00m
16.00m
52.5'
78.7' 24.00m
105.0' 32.00m
32.00m
105.0'
131.2' 40.00m
MOUNTING HEIGHT: 33'(10.0m)
3% 0.4167lx 0.03871fc 5% 0.6944lx 0.06452fc 10% 1.389lx 0.129fc 30% 4.167lx 0.3871fc 50% 6.944lx 0.6452fc
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 10 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 4112.89 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.3085 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
412160 397565 379270 354175 317180 258885 1449
104175404338773643323424121399
204258413539763752334427261916
304353423540823867353930402299
404454434241933984368632312643
504556445042994098380633762816
604652454443974199390934912723
704723461744774280399035732322
804773466945324334405036272050
904792469745574358407936531963
1004781468645454349407136552079
1104738463945034309403236282379
1204672457344344243396135532816
1304584448143424143385334402929
1404487438342324027373032982762
1504392427641163902357530992422
1604297417340053756334727652002
1704216407839073654317223781400
1804155401338263569318825981318
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories
CIBSECategory
Gamma(deg)
Average Luminancemaximum
calculatedspecifiedmaximum
Patch Luminancemaximummeasured
specifiedmaximum
Category 1Category 2Category 3
55 to 9065 to 9075 to 90
479245574079
200200200
---------
500500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 11 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 4112.89 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.3085 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
412160 397565 379270 354175 317180 258885 1449
104175404338773643323424121399
204258413539763752334427261916
304353423540823867353930402299
404454434241933984368632312643
504556445042994098380633762816
604652454443974199390934912723
704723461744774280399035732322
804773466945324334405036272050
904792469745574358407936531963
1004781468645454349407136552079
1104738463945034309403236282379
1204672457344344243396135532816
1304584448143424143385334402929
1404487438342324027373032982762
1504392427641163902357530992422
1604297417340053756334727652002
1704216407839073654317223781400
1804155401338263569318825981318
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits
Average Luminance(cd/sq.m)Maximum limit for screen type & software category usedrange
(deg)
55 to 9065 to 90
Maximummeasured
47924557
Type I,II screenSome neg.s'ware
10001000
Type I,II screenOnly pos.s'ware
15001500
Type III screenSome neg.s'ware
200200
Type III screenOnly pos.s'ware
500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25Distance(m)
0
1.5
3
4.5
6
7.5
9
10.5
12
13.5
15E(lx) MH = 10 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:25.2DEG Humidity:66%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-11-10 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 1 Of 12
LUMINAIRE PHOTOMETRIC TEST REPORT
DIM.:
MFR.: Light-green
SPEC.:
SUR.:0.27m*0.27m
030
60
90
120
150-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,112.8°
UNIT:cd
C30/210,111.9°
UNIT:cd
C60/240,110.7°
UNIT:cd
C90/270,109.8°AVERAGE BEAM ANGLE(50%):111.3 DEG
0
90
180
270
360
450
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM C0 PLANE ISOLUX DIAGRAM (UNIT:lx)MH(m)
14
18
22
26
30
34
38
42
46
0.0 17.0 34.0S(m)2.40
2.001.601.20
0.8100
0.40000.32000.20000.16000.1200
DATA OF LAMP PHOTOMETRIC DATA Eff: 56.56 lm/W
NOMINAL POWER(W)RATED VOLTAGE(V)NOMINAL FLUX(lm)LAMPS INSIDETEST VOLTAGE(V)
LOR(%)TOTAL FLUX(lm)CIE CLASS up(%) down(%)η
η
S/MH(C90/270) UP,DN(C0-180) UP,DN(C180-360)CIBSE SHR NOMCIBSE SHR MAX
η
η
202121131.191212.4
100.01131.2DIRECT0.0100.0
1.270.0,51.60.0,48.41.251.35
AAAAAAAAAAAAAAAAAAAAAAAAAAA
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000] Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Test:U:212.0V I:0.1830A P:20.00W PF:0.6130 Lamp Flux:1131.19x1 lmNAME: LED Plane Light TYPE:warm white WEIGHT:5KG
MODEL LGI-C3030IDA-Q Imax(cd) 403.3 S/MH(C0/180) 1.28
Light Green International Co.Ltd Page 2 Of 12
ZONAL FLUX DIAGRAMAND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM:
γ 5 0- 5 10 5- 10 15 10- 15 20 15- 20 25 20- 25 30 25- 30 35 30- 35 40 35- 40 45 40- 45 50 45- 50 55 50- 55 60 55- 60 65 60- 65 70 65- 70 75 70- 75 80 75- 80 85 80- 85 90 85- 90 95 90- 95 100 95-100 105 100-105 110 105-110 115 110-115 120 115-120 125 120-125 130 125-130 135 130-135 140 135-140 145 140-145 150 145-150 155 150-155 160 155-160 165 160-165 170 165-170 175 170-175 180 175-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp γ Φ Φ
DEG LUMINOUS INTENSITY:cd UNIT:lm
401.8 400.9 401.0 401.1 402.1 399.2 398.4 399.1 9.598 9.598 0.85,0.85397.7 397.2 398.7 397.5 398.2 393.8 393.5 393.5 28.48 38.08 3.37,3.37390.7 391.1 389.2 391.5 391.4 385.9 381.4 385.5 46.50 84.57 7.48,7.48380.5 379.4 379.7 379.8 381.3 372.4 369.3 371.7 62.98 147.5 13,13366.7 366.0 363.0 366.6 367.6 357.2 349.9 356.4 77.41 225.0 19.9,19.9349.2 348.3 346.3 348.8 350.0 337.6 330.5 336.8 89.12 314.1 27.8,27.8327.8 326.8 323.1 327.3 328.2 314.3 305.2 313.5 97.76 411.8 36.4,36.4303.1 303.5 300.0 303.8 302.6 289.1 280.0 288.6 102.8 514.7 45.5,45.5275.3 275.4 272.0 275.3 274.2 259.4 250.6 259.5 104.3 619.0 54.7,54.7244.8 246.9 244.0 246.3 243.2 229.4 221.2 230.1 102.1 721.0 63.7,63.7212.0 214.8 212.7 213.7 210.4 196.2 189.3 197.5 96.41 817.4 72.3,72.3177.6 182.6 181.5 181.1 176.2 163.2 157.5 164.9 87.46 904.9 80,80142.4 148.0 148.5 146.7 141.1 129.0 124.4 130.3 75.71 980.6 86.7,86.7106.8 113.5 115.4 112.5 105.6 95.14 91.24 96.01 61.52 1042 92.1,92.171.85 79.02 82.57 78.17 70.69 61.71 60.70 62.16 45.74 1088 96.2,96.239.28 47.02 49.73 46.47 38.00 33.23 30.16 33.37 29.40 1117 98.8,98.812.77 11.84 0 11.68 11.56 7.096 0 7.079 12.83 1130 99.9,99.91.149 0 0 0 0.2930 0 0 0 1.075 1131 100,100
LUMINANCE LIMITATION CURVESGLARE CLASS ILLUMINANCE (lx)1.15 A 2000 1000 500 <=3001.50 B 2000 1000 500 <=3001.85 C 2000 1000 500 <=3002.20 D 2000 1000 500 <=3002.55 E 2000 1000 500 <=300
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 4 1
2
3468
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)G(DEG) C0/180 C90/27085 2010 080 3103 392975 3808 437670 4284 462965 4621 481960 4873 497955 5070 508750 5223 520645 5340 5276
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 3 Of 12
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
cc w fc
ρ
ρ
ρ
RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
1.191.04.91.80.71.63.57.52.47.43.40
1.191.00.84.72.62.54.48.43.39.35.32
1.19.96.79.65.55.48.42.37.33.29.27
1.161.02.89.78.70.62.56.51.46.43.39
1.16.98.83.71.61.54.48.43.38.35.32
1.16.95.78.65.55.47.41.37.33.29.27
1.11.98.86.75.67.60.54.49.45.41.38
1.11.95.80.69.60.53.47.42.38.34.31
1.11.92.76.64.54.47.41.36.32.29.27
1.06.94.82.73.65.58.53.48.44.40.37
1.06.91.78.67.58.52.46.41.37.34.31
1.06.89.74.63.53.46.41.36.32.29.26
1.02.90.79.70.62.56.51.46.43.39.37
1.02.88.76.65.57.50.45.40.37.33.31
1.02.86.72.61.53.46.40.36.32.29.26
.00
.84
.70
.59
.51
.44
.38
.34
.30
.27
.25
AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k2
3
4
56789
10
20
30
40
50LAMPS LUMINAIRE BUDGETARY DIAGRAM
2
3
4
H=5H=5
55
66
77
H=8H=8
CONDITIONSFLUX 1000lm
FACTOR 0.70Hdown 0.00mHwork 0.80m
Ework(AVE) 100lxρ (%) cc w fc
70 50 3050 30 20
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 4 Of 12
WEC AND CCEC
cc w fc
ρ
ρ
ρ
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.301
.286
.266
.246
.228
.212
.198
.185
.173
.163
.171
.157
.142
.128
.116
.106
.098
.090
.084
.078
.054
.048
.042
.038
.034
.030
.028
.025
.023
.022
.294
.280
.261
.242
.224
.208
.194
.182
.170
.160
.167
.154
.140
.126
.115
.105
.097
.089
.083
.078
.053
.048
.042
.037
.033
.030
.028
.025
.023
.022
.280
.268
.250
.232
.216
.201
.188
.176
.165
.156
.161
.149
.136
.123
.112
.103
.095
.088
.082
.076
.051
.046
.041
.037
.033
.030
.027
.025
.023
.021
.268
.258
.241
.224
.208
.194
.182
.170
.160
.151
.155
.144
.132
.120
.110
.101
.093
.086
.080
.075
.050
.045
.040
.036
.033
.030
.027
.025
.023
.021
.257
.248
.232
.216
.201
.188
.176
.165
.156
.147
.149
.140
.128
.117
.108
.099
.091
.085
.079
.074
.048
.044
.040
.036
.032
.029
.027
.025
.023
.021
cc w fc
ρ
ρ
ρ
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%50% 30% 10%
20%
70%50% 30% 10%
20%
50%50% 30% 10%
20%
30%50% 30% 10%
20%
10%50% 30% 10%
20%
000
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.010.0
.190
.180
.171
.164
.156
.149
.142
.135
.129
.123
.117
.190
.156
.132
.114
.101
.091
.082
.075
.069
.064
.060
.190
.135
.099
.075
.059
.047
.039
.033
.029
.025
.022
.163
.154
.147
.140
.134
.128
.122
.116
.111
.106
.101
.163
.134
.114
.099
.087
.078
.071
.065
.060
.056
.052
.163
.116
.085
.065
.051
.041
.034
.029
.025
.022
.020
.111
.105
.101
.096
.092
.088
.084
.080
.077
.073
.070
.111
.092
.079
.068
.061
.055
.050
.046
.042
.039
.037
.111
.080
.060
.046
.036
.029
.024
.021
.018
.016
.014
.064
.061
.058
.056
.053
.051
.049
.047
.045
.043
.041
.064
.053
.046
.040
.036
.032
.029
.027
.025
.023
.022
.064
.047
.035
.027
.021
.017
.014
.012
.011
.009
.008
.020
.019
.019
.018
.017
.016
.016
.015
.014
.014
.013
.020
.017
.015
.013
.012
.010
.010
.009
.008
.008
.007
.020
.015
.011
.009
.007
.006
.005
.004
.004
.003
.003
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 5 Of 12
Uncorrected UGR Table
ceiling/cavitywalls
working planeRoom dimensions Viewed crosswise Viewed endwise
0.7 0.70.5 0.50.2 0.2
0.7 0.70.3 0.30.2 0.2
0.5 0.50.5 0.50.2 0.2
0.5 0.50.3 0.30.2 0.2
0.3 0.30.3 0.30.2 0.2
x = 2H y = 2H 3H 4H 6H 8H 12H
4H 2H 3H 4H 6H 8H 12H
8H 4H 6H 8H 12H
12H 4H 6H 8H
18.7 18.7 20.2 20.2 18.9 19.0 20.4 20.4 20.6 20.6 20.1 20.3 21.5 21.7 20.4 20.6 21.7 21.9 22.0 22.1 20.7 20.9 22.0 22.2 21.0 21.2 22.2 22.5 22.5 22.7 21.0 21.4 22.2 22.6 21.3 21.7 22.5 22.9 22.8 23.2 21.1 21.5 22.3 22.7 21.4 21.8 22.5 22.9 22.8 23.2 21.1 21.4 22.2 22.6 21.4 21.8 22.5 22.9 22.8 23.2
19.3 19.3 20.6 20.6 19.6 19.6 20.9 20.9 21.1 21.2 20.9 21.1 22.1 22.2 21.3 21.4 22.4 22.5 22.7 22.8 21.6 21.8 22.6 22.9 22.0 22.2 23.0 23.2 23.3 23.6 22.0 22.4 23.0 23.4 22.4 22.8 23.3 23.7 23.7 24.1 22.2 22.6 23.0 23.4 22.6 23.0 23.4 23.8 23.8 24.2 22.2 22.5 23.0 23.3 22.6 23.0 23.4 23.7 23.8 24.1
21.9 22.1 22.7 23.0 22.3 22.5 23.1 23.3 23.5 23.7 22.5 22.8 23.2 23.6 22.9 23.3 23.6 24.0 24.0 24.4 22.7 23.0 23.3 23.7 23.1 23.5 23.7 24.1 24.2 24.5 22.8 23.0 23.3 23.6 23.2 23.5 23.8 24.0 24.2 24.5
21.9 22.1 22.7 22.9 22.3 22.5 23.1 23.3 23.5 23.7 22.5 22.9 23.2 23.5 23.0 23.3 23.6 23.9 24.0 24.4 22.8 23.1 23.3 23.6 23.2 23.6 23.7 24.1 24.2 24.6
Variations with the observer position at spacings:S = 1.0H + 0.2 / - 0.2 + 0.1 / - 0.2 1.5H + 0.2 / - 0.3 + 0.2 / - 0.3 2.0H + 0.2 / - 0.3 + 0.2 / - 0.3
CIE Pub.117 Corrected 1131 lm Total Lamp Luminous Flux.(8log(F/F0) = 0.4)
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 6 Of 12
UTILIZATION FACTORS TABLE
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 58 46 39 57 46 39 56 46 39 33
0.80 68 57 49 67 56 49 65 55 49 42
1.00 77 66 58 75 65 58 73 66 58 50
1.25 84 73 66 82 73 66 80 71 65 58
1.50 89 79 72 87 78 72 84 76 70 63
2.00 95 87 81 94 86 80 90 84 79 71
2.50 99 92 86 97 90 85 94 88 83 75
3.00 103 96 91 101 94 90 97 92 87 79
4.00 107 101 97 104 99 95 100 96 93 84
5.00 109 104 100 107 102 99 102 99 96 87
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 7 Of 12
ISOCANDELA DIAGRAM
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90HORIZONTAL(DEG)
VERT
ICAL
(DEG
)
Imax:403.3(H-1.0,V0.0) (At:C=0.0,Gamma=0.0)
UNIT: cd
10% 40.3320% 80.6530% 121.040% 161.350% 201.660% 242.070% 282.380% 322.690% 362.9
MAX = 403.26 MIN = 192.46 AVG = 330.78 AVG/MAX = 0.82MIN/MAX = 0.48
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 8 Of 12
AAI Figure
1m3.281ft
284.83cm9.345ft
127.6,403.3lx11.85,37.47fc
2m6.562ft
569.67cm18.69ft
31.89,100.8lx2.963,9.367fc
3m9.843ft
854.50cm28.03ft
14.17,44.81lx1.317,4.163fc
4m13.12ft
1139.34cm37.38ft
7.973,25.21lx0.7408,2.342fc
5m16.4ft
1424.17cm46.72ft
5.103,16.13lx0.4741,1.499fc
Height Eavg,Emax DiameterAngle:109.85deg
Flux out:817.4 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 9 Of 12
ISOLUX DIAGRAM
131.2' 40.00m
105.0' 32.00m
32.00m
105.0'
78.7' 24.00m
52.5' 16.00m
16.00m
52.5'
26.2' 8.00m
0.0' 0.00m
0.00m
0.0'
26.2' 8.00m
52.5' 16.00m
16.00m
52.5'
78.7' 24.00m
105.0' 32.00m
32.00m
105.0'
131.2' 40.00m
MOUNTING HEIGHT: 33'(10.0m)
3% 0.1210lx 0.01124fc 5% 0.2016lx 0.01873fc 10% 0.4032lx 0.03746fc 30% 1.210lx 0.1124fc 50% 2.016lx 0.1873fc
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 10 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 1131.19 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.0729 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
507060 487365 462170 428475 380880 310385 2010
105092490446804340389132052209
205122496147144412399133522477
305137498547604475407834782568
405145499747934535415836562147
505136499948224571422737561560
60512849894833460343053821958
70510249824825462443543880453
80508849774818462743753931118
905087497948194629437639290
100509149794819462543663907117
110510649844818459743143830447
120512549704799455842543773945
1305115496447794526418137111539
1405115495647504495411436192115
1505100494847204436404434472527
1605082492146794376394433072436
1705051486646474297383531402126
1805031483345794235374630021820
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories
CIBSECategory
Gamma(deg)
Average Luminancemaximum
calculatedspecifiedmaximum
Patch Luminancemaximummeasured
specifiedmaximum
Category 1Category 2Category 3
55 to 9065 to 9075 to 90
514548334376
200200200
---------
500500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 11 Of 12
Average Luminance Table(CIBSE)
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
Parameter description for average Luminance Symbol Value UnitLuminance in Azimuth Plane Bc refer Table 2 cd/sq.m.Intensity at angle Gamma in given azimuth plane I from data cd/klmNumber of lamps N 1Output of each lamp(initial lumens as specified) F 1131.19 lmMultiplying factor K 1Luminous area in horizontal plane used in calculations A 0.0729 sq.m.Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
Gdeg
C plane(deg)
550
507060 487365 462170 428475 380880 310385 2010
105092490446804340389132052209
205122496147144412399133522477
305137498547604475407834782568
405145499747934535415836562147
505136499948224571422737561560
60512849894833460343053821958
70510249824825462443543880453
80508849774818462743753931118
905087497948194629437639290
100509149794819462543663907117
110510649844818459743143830447
120512549704799455842543773945
1305115496447794526418137111539
1405115495647504495411436192115
1505100494847204436404434472527
1605082492146794376394433072436
1705051486646474297383531402126
1805031483345794235374630021820
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits
Average Luminance(cd/sq.m)Maximum limit for screen type & software category usedrange
(deg)
55 to 9065 to 90
Maximummeasured
51454833
Type I,II screenSome neg.s'ware
10001000
Type I,II screenOnly pos.s'ware
15001500
Type III screenSome neg.s'ware
200200
Type III screenOnly pos.s'ware
500500
No match
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树
Light Green International Co.Ltd Page 12 Of 12
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25Distance(m)
0
0.45
0.9
1.35
1.8
2.25
2.7
3.15
3.6
4.05
4.5E(lx) MH = 10 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 5.0DEG
Range: 0 - 90DEG Interval: 0.5DEGγγ
Test Speed: LOW Test System:EVERFINE GO-2000A_V1 SYSTEM V2.0.261Temperature:23.1DEG Humidity:40%
Test Distance:5.400m [K=1.0000]Operators:王林飞Test Date:2010-12-16 Remarks:
Checker: Assessor: 张树