Post on 30-May-2015
Series RSM Room Status Monitor
The materials included in this compilation are for the use of Dwyer Instruments, Inc. potential customers and current employees as a resource only. They may not be reproduced, published, or transmitted electronically for commercial purposes. Furthermore, the Company’s name, likeness, product names, and logos, included within these compilations may not be used without specific, written prior permission from Dwyer Instruments, Inc.
©Copyright 2011 Dwyer Instruments, Inc
Room Status Monitor
Monitors Pressure in critical Positive or Negative Isolation Rooms and Environments
Key Features
+/- 0.5% F.S. AccuracyPositive and Negative monitoringRanges as low as +/- 12.5 PaField Selectable 4-20 mA, 0-10 or 0-5 VDC120 VAC or 24 VAC powered modelsOptional BACnet® communication
Key Features
Local Red / Green LED Status IndicatorsLocal Audible Alarm (max 85 dB @ 10 cm)SPDT relay for remote alarm notificationBacklit Color LCD DisplayTouch-screen User InterfaceDoor Status Monitor (digital input)
Key Benefits
Resolution of 0.025 Pa!
High accuracy room-to-room pressure monitoring
Local verification of pressure condition in target area (Safe/Unsafe)
LED Indicator Lights – Quick Verification
Normal
Alarm
Instant “Safe/Unsafe” Validation
Key Benefits
Key Benefits
Color-Coded LCD Display – Indicates Condition
If Pressure is Normal, the screen is GREEN
Key Benefits
Color-Coded LCD Display – Indicates Condition
If Pressure is Normal, and the Door is Open, the screen is YELLOW
+
Key Benefits
Door Status Monitor – Digital Input
Door Closed – Closed CircuitDoor Open – Open Circuit
Installed in Door Installed in Frame
To RSM
Key Benefits
Color-Coded LCD Display – Indicates Condition
OR+
If Pressure falls outside the preset limits (Alarmed State),
the screen is RED
Typical Installation
Applications
Clean RoomsPharmaceuticalSemiconductor
Hospital RoomsResearch Labs
Applications
Clean RoomsAn area with a controlled level of particulate contaminationPositively Pressurized : In case of leaks, clean air leaks out instead of dirty air rushing in.Common in manufacturing facilities
Pharmaceutical, semiconductor
Applications
Clean Rooms
Applications
Hospitals – Airborne Infectious Isolation Rooms
Negatively PressurizedLimit the movement of germs from the patient room to other areas in the building
Tuberculosis, influenza patients
Applications
Hospitals – Operating Rooms
Positively PressurizedLimit the movement of airborne germs into the operating room
Applications
Hospitals – Protective Environment Rooms
Positively PressurizedProtects patients from germs elsewhere in the building
Applications
Research LabsNegatively PressurizedEnsures proper airflow, temperature and humidity in lab areaConfines hazardous materials to the lab area
Ways to Sell
Excellent Monitor for Building ManagementAt-A-Glance Verification of Room ConditionSimple Touchscreen Setup and Calibration
Questions
To order a free catalog or for more information contact;Dwyer Instruments, Inc., P.O. Box 373,
Michigan City, IN., 46361Telephone: (800) 872-9141 or (219) 879-8000
Fax: (219) 872-9057Internet address: www.dwyer-inst.com
E-mail: info@dwyer-inst.com