Process controllerdTRON 316 in Rittal-cabinetwith current loop sensor input for controlling pneumatic and electric actuators with a position controller via the 4-20 mA output
••
Process controllerfor pneumatic and electric actuators
Process controller 110-240V
Features Rittal cabinet RAL 7035dTRON 316 process controllerSensor input for current loopPower supply 110 V-240 VACOn / off switchOptions: -Profibus card
••••••
Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com! Data sheet 000023 englisch
2
Process controllerdTRON 316
Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!
Working principle The controller has two four-digit, 7-segment displays for process values (red) and setpoints (green). The displays can be used to add comments when you program your inputs. The controller has one analog input for any common transducer type, two relay outputs, two combined binary inputs / logic outputs and one 4-20 mA analog output for controlling actuators.One free slot is provided to allow an additional option, such as a Profibus card, to be retrofitted if required. The controller is also equipped with four limit comparators that can be assigned to the source signals. You can choose between eight different limit comparator functions. One program function with eight program segments and two autotuning (self-optimization) methods (oscillation and step response) are provided as standard.
Key features - Programmable analog input- 2 autotuning methods- Program function with 8 segments or ramp function- 2 timer functions- 4 limit comparators- Key and level inhibit- 4 programmable setpoints, 2 parameter sets- 4-digit resolution (max. 2 decimal places)- Controller structures: P, PD, PI or PID- Process value inputs for all common transducer types (see technical data)- 2 relay outputs 230 V / 3 A (NO)- 2 combinable binary inputs / logic outputs- Analog output 4-20 mA
Function diagram
Input resistance thermometer Resistance- transmitter
Thermo- couple
Current 0(4)...20mA
Voltage 0(2)...10V
4 .... 20 mA
or
3
Process controllerTechnical data
Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!
Inside view
Power supply unit for current loopFuse holder (current loop)
Power input4-20 mA output for actuator
Sensor inputs- Resistance thermometer- Thermocouples- Standard signals
If sensors are clamped here, please remove the 6,3x32 mm / 0,05 A medium-slow microfuse for the current loop!
Sensor input for 4-20 mA current loope.g. pressure sensors in two-wire
circuit
Technical data: GeneralType Process controllerSupply voltage VAC 110-240 VACOvercurrent protection (current loop) Microfuse 6,3 x 32 mm 0,05 A MTOvercurrent protection (customer) A max. 6 APower consumption VA max. 8 VAProtection to DIN 60529 IP65 (controller)Storage temperature °C -30 …+70 °CMax. ambient temperature °C 0 ... +55 °CDimensions B x H x T mm 200 mm x 300 mm x 155 mmPainting RAL 7035 powder coating
Relais2 x normally open contact (NO) Contact rating: 3 A, 250 V AC at resistive load, contact life: > 350.000 operations at 1A
Max. conductor cross-section mm2 2,5 mm2
Cable glands 2 x M20x1,5, 2 x M16x1,5Weight kg 5,2 kgNote: If sensors are clamped to terminals 1 to 4, the 6,3x32 mm / 0,05 A medium-slow microfuse for the current loop must be removed.
4
Process controllerTechnical data dTRON 316
Thermocouple input Designation Measuring range Measuring accuracy Ambient temperature error Fe-CuNi „L“ -200 … +900°C ≤0,25% 100 ppm/K
Fe-CuNi „J“ DIN EN 60584 -200 … +1200°C ≤0,25% 100 ppm/K
Cu-CuNi „U“ -200 … +600°C ≤0,25% 100 ppm/K
Cu-CuNi „T“ DIN EN 60584 -200 … +400°C ≤0,25% 100 ppm/K
NiCr-Ni „K“ DIN EN 60584 -200 … +1372°C ≤0,25% 100 ppm/K
NiCr-CuNi „E“ DIN EN 60584 -200 … +1000°C ≤0,25% 100 ppm/K
NiCrSi-NiSi „N“ DIN EN 60584 -100 … +1300°C ≤0,25% 100 ppm/K
Pt10Rh-Pt „S“ DIN EN 60584 0 … +1768°C ≤0,25% 100 ppm/K
Pt13Rh-Pt „R“ DIN EN 60584 0 … +1768°C ≤0,25% 100 ppm/K
Pt30Rh-Pt6Rh „B“ DIN EN 60584 0 … +1820°C ≤0,25% (in the range +300…+1820°C 100 ppm/K
W5Re-W26Re „C“ 0 … +2320 °C ≤0,25% 100 ppm/K
W3Re-W25Re „D“ 0 … +2495 °C ≤0,25% 100 ppm/K
W3Re-W26Re 0 … +2400 °C ≤0,25% 100 ppm/K
Cold junction Pt 100 internal
Input for resistance thermometer
Designation Connection Measuring range Measuring accuracy Ambient
temperature error 3-wire 2-wire
Pt100 (standard) DIN EN 60751 2-Leiter / 3-Leiter -200 ... +850°C ≤0,05% ≤0,4% 50 ppm/K
Pt500 DIN EN 60751 2-Leiter / 3-Leiter -200 ... +850°C ≤0,2% ≤0,4% 100 ppm/K
Pt1000 DIN EN 60751 2-Leiter / 3-Leiter -200 ... +850°C ≤0,1% ≤0,2% 50 ppm/K
KTY11-6 2-Leiter -50 ... +150°C -- ≤2,0% 50 ppm/K
Sensor lead resistance max. 30 Ω per lead for 3-wire circuit
Measuring current ca. 250 µA
Lead compensation Not required for 3-wire circuit. With a 2-wire circuit, the lead resistance can be compensated in software by a correction of the process value.
Input for standard signals
Designation Measuring range Measuring accuracy Ambient temperature error
Voltage 0(2) … 10V Input resistance RE > 100kΩ ≤0,05% 100 ppm/K
Current 0(4) … 20mA, voltage drop ≤ 1,5V ≤0,05% 100 ppm/K
Logic inputsFloating contacts
Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!
5
Process controllerTechnical data dTRON 316
Measuring circuit monitoringIn the event of a fault, the outputs move to a defined (configurable) status.
Sensor Overrange / underrange Probe or lead short-circuit Probe or lead breakThermocouple • -- • Resistance thermometer • • •
Voltage 2…10V • • • 0…10V • -- --
Current 4…20mA • • • 0…20mA • -- --
• = recognized / -- = not recognized
Outputs
Relay (make) contact rating 3 A at 230 V AC resistive load
contact life 150.000 operations at rated load / 350,000 at 1A
Logic output 0/12 V / 30 mA max. (sum of all output currents)
ControllerController type continuous
Controller structures P/PD/PI/PID
A/D converter dynamic resolution up to 16-bit
Sampling time 250 ms
Electrical data Supply voltage (switchmode PSU) AC 110 … 240 V -15/+10%, 48 … 63 Hz
Electrical safetyacc. to DIN EN 61010, part 1
overvoltage category III, pollution degree 2 Power consumption Type 703041: max. 8 VA
Data backup EEPROM
Electrical connection
at the back, via screw terminals,, conductor cross-section up to max. 2,5 mm2
with core ferrules (length: 10 mm)
Conductor cross-sections and core-end ferrules for installationminimum cross-sectional
maximum cross-sectional
Min. length of core-end ferrule
without ferrule 0,34 mm2 2,5 mm2 10 mm (stripped)
Ferrule, no lip 0,25 mm2 2,5 mm2 10 mm
Ferrule, with lip up to 1,5mm2 0,25 mm2 1,5 mm2 10 mm
Ferrule, with lip above 1,5mm2 1,5 mm2 2,5 mm2 12 mm
Twin ferrule, with lip 0,25 mm2 1,5 mm2 12 mm
Electromagnetic compatibility DIN EN 61 326
Interference emission Classe B
Interference immunity to industrial requirements
Housing Housing type plastic housing for panel mounting to DIN 43700
Depth behind panel 90 mm
Ambient/storage temperature range 0 ... +55 °C / -30…+70 °C
Climatic conditions rel. humidity ≤ 90% annual mean, no condensation
Operating position horizontal
Protection acc. to DIN EN 60529, front IP 65, back IP 20
Weight (fully fitted) Typ 703041: ca. 220 g
Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!
6
Process controllerAccessories
Pressure transmitter MIDAS S05
Measuring ranges: 1 bar to 100 bar (relative pressure)1 bar to 25 bar (absolute pressure)
Pressure types: Relative or absolute pressure
Measuring system: Silicon sensor with stainless steel separating diaphragm
Accuracy levels: From 0,2% of final value of measuring range
Outputs: 4...20 mA, DC 0,5...4,5 V, DC 0...10 V, DC 1...5 V, DC 1...6 V
Temperatures of measured media: -40 ... +125 °C
Protection class acc. to DIN EN 60529:
Fixed cable (standard) - Measuring range IP66 (relative pressure) - Measuring range IP67 (absolute pressure)
Electrical connections: Round plug, M12 x 1
Pressure connections: Large number of threadsAreas of application: - HVAC (Heating, Ventitating and Airconditioning)
- Compressure construction- Packaging industry- Industrial pneumatic uses- Level
Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!
7Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!
Process controllerCircuit diagram
Note
: If s
enso
rs ar
e clam
ped t
o ter
mina
ls 1 t
o 4, th
e 6,3
x32 m
m / 0
,05 A
mediu
m-slo
w mi
crofus
e for
the
curre
nt loo
p mus
t be r
emov
ed.
Limit v
iolati
onflo
ating
3 A
/ 230
V ou
tput
Sens
or br
eak
floati
ng 3
A / 2
30 V
outpu
t Analo
g outp
ut
- 4 ...
. 20 m
A Se
nsor
inpu
t for 4
...20 m
A cu
rrent
loop
+ 4 .
... 20
mA
Sens
or in
put fo
r 4...2
0 mA
curre
nt loo
p
6,3 x
32 m
m 24
V 0,
05 A
fuse
LED
lights
whe
n fus
e blow
s
Note
: Pr
otec
t the
pow
er in
put
with
a 6 A
fuse
!
ON-O
FF sw
itch
90°
Cut o
ff cab
les 5
+ 6 y
ellow
/ gre
en
Cove
r gro
und
Bina
ry inp
ut 2
Bina
ry inp
ut 1
4 x 0,
5 mm
2 o. y
ellow
/ gre
en
12 x
0,5 m
m2
0,5 mm2 core (red)
Technik mit Zukunft.DEUTSCHE QUALITÄTSARMATUREN
ARI-ArmaturenAlbertRichterGmbH&Co.KG,D-33750SchloßHolte-Stukenbrock,Tel.+49(0)5207/994-0,Telefax+49(0)5207/994-297oder298Internet:http://www.ari-armaturen.comE-mail:info.vertrieb@ari-armaturen.com
8 Edition03/12-Datasubjecttoalteration-Regularlyupdateddataonwww.ari-armaturen.com!
Process controllerDimensions
Technology for the Future.G E R M A N Q U A L I T Y V A L V E S