Process controller - ARI Armaturen

8
Process controller dTRON 316 in Rittal-cabinet with current loop sensor input for controlling pneumatic and electric actuators with a position controller via the 4-20 mA output Process controller for pneumatic and electric actuators Process controller 110-240V Features Rittal cabinet RAL 7035 dTRON 316 process controller Sensor input for current loop Power supply 110 V-240 VAC On / off switch Options: -Profibus card Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com! Data sheet 000023 englisch

Transcript of Process controller - ARI Armaturen

Page 1: Process controller - ARI Armaturen

Process controllerdTRON 316 in Rittal-cabinetwith current loop sensor input for controlling pneumatic and electric actuators with a position controller via the 4-20 mA output

••

Process controllerfor pneumatic and electric actuators

Process controller 110-240V

Features Rittal cabinet RAL 7035dTRON 316 process controllerSensor input for current loopPower supply 110 V-240 VACOn / off switchOptions: -Profibus card

••••••

Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com! Data sheet 000023 englisch

Page 2: Process controller - ARI Armaturen

2

Process controllerdTRON 316

Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

Working principle The controller has two four-digit, 7-segment displays for process values (red) and setpoints (green). The displays can be used to add comments when you program your inputs. The controller has one analog input for any common transducer type, two relay outputs, two combined binary inputs / logic outputs and one 4-20 mA analog output for controlling actuators.One free slot is provided to allow an additional option, such as a Profibus card, to be retrofitted if required. The controller is also equipped with four limit comparators that can be assigned to the source signals. You can choose between eight different limit comparator functions. One program function with eight program segments and two autotuning (self-optimization) methods (oscillation and step response) are provided as standard.

Key features - Programmable analog input- 2 autotuning methods- Program function with 8 segments or ramp function- 2 timer functions- 4 limit comparators- Key and level inhibit- 4 programmable setpoints, 2 parameter sets- 4-digit resolution (max. 2 decimal places)- Controller structures: P, PD, PI or PID- Process value inputs for all common transducer types (see technical data)- 2 relay outputs 230 V / 3 A (NO)- 2 combinable binary inputs / logic outputs- Analog output 4-20 mA

Function diagram

Input resistance thermometer Resistance- transmitter

Thermo- couple

Current 0(4)...20mA

Voltage 0(2)...10V

4 .... 20 mA

or

Page 3: Process controller - ARI Armaturen

3

Process controllerTechnical data

Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

Inside view

Power supply unit for current loopFuse holder (current loop)

Power input4-20 mA output for actuator

Sensor inputs- Resistance thermometer- Thermocouples- Standard signals

If sensors are clamped here, please remove the 6,3x32 mm / 0,05 A medium-slow microfuse for the current loop!

Sensor input for 4-20 mA current loope.g. pressure sensors in two-wire

circuit

Technical data: GeneralType Process controllerSupply voltage VAC 110-240 VACOvercurrent protection (current loop) Microfuse 6,3 x 32 mm 0,05 A MTOvercurrent protection (customer) A max. 6 APower consumption VA max. 8 VAProtection to DIN 60529 IP65 (controller)Storage temperature °C -30 …+70 °CMax. ambient temperature °C 0 ... +55 °CDimensions B x H x T mm 200 mm x 300 mm x 155 mmPainting RAL 7035 powder coating

Relais2 x normally open contact (NO) Contact rating: 3 A, 250 V AC at resistive load, contact life: > 350.000 operations at 1A

Max. conductor cross-section mm2 2,5 mm2

Cable glands 2 x M20x1,5, 2 x M16x1,5Weight kg 5,2 kgNote: If sensors are clamped to terminals 1 to 4, the 6,3x32 mm / 0,05 A medium-slow microfuse for the current loop must be removed.

Page 4: Process controller - ARI Armaturen

4

Process controllerTechnical data dTRON 316

Thermocouple input Designation Measuring range Measuring accuracy Ambient temperature error Fe-CuNi „L“ -200 … +900°C ≤0,25% 100 ppm/K

Fe-CuNi „J“ DIN EN 60584 -200 … +1200°C ≤0,25% 100 ppm/K

Cu-CuNi „U“ -200 … +600°C ≤0,25% 100 ppm/K

Cu-CuNi „T“ DIN EN 60584 -200 … +400°C ≤0,25% 100 ppm/K

NiCr-Ni „K“ DIN EN 60584 -200 … +1372°C ≤0,25% 100 ppm/K

NiCr-CuNi „E“ DIN EN 60584 -200 … +1000°C ≤0,25% 100 ppm/K

NiCrSi-NiSi „N“ DIN EN 60584 -100 … +1300°C ≤0,25% 100 ppm/K

Pt10Rh-Pt „S“ DIN EN 60584 0 … +1768°C ≤0,25% 100 ppm/K

Pt13Rh-Pt „R“ DIN EN 60584 0 … +1768°C ≤0,25% 100 ppm/K

Pt30Rh-Pt6Rh „B“ DIN EN 60584 0 … +1820°C ≤0,25% (in the range +300…+1820°C 100 ppm/K

W5Re-W26Re „C“ 0 … +2320 °C ≤0,25% 100 ppm/K

W3Re-W25Re „D“ 0 … +2495 °C ≤0,25% 100 ppm/K

W3Re-W26Re 0 … +2400 °C ≤0,25% 100 ppm/K

Cold junction Pt 100 internal

Input for resistance thermometer

Designation Connection Measuring range Measuring accuracy Ambient

temperature error 3-wire 2-wire

Pt100 (standard) DIN EN 60751 2-Leiter / 3-Leiter -200 ... +850°C ≤0,05% ≤0,4% 50 ppm/K

Pt500 DIN EN 60751 2-Leiter / 3-Leiter -200 ... +850°C ≤0,2% ≤0,4% 100 ppm/K

Pt1000 DIN EN 60751 2-Leiter / 3-Leiter -200 ... +850°C ≤0,1% ≤0,2% 50 ppm/K

KTY11-6 2-Leiter -50 ... +150°C -- ≤2,0% 50 ppm/K

Sensor lead resistance max. 30 Ω per lead for 3-wire circuit

Measuring current ca. 250 µA

Lead compensation Not required for 3-wire circuit. With a 2-wire circuit, the lead resistance can be compensated in software by a correction of the process value.

Input for standard signals

Designation Measuring range Measuring accuracy Ambient temperature error

Voltage 0(2) … 10V Input resistance RE > 100kΩ ≤0,05% 100 ppm/K

Current 0(4) … 20mA, voltage drop ≤ 1,5V ≤0,05% 100 ppm/K

Logic inputsFloating contacts

Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

Page 5: Process controller - ARI Armaturen

5

Process controllerTechnical data dTRON 316

Measuring circuit monitoringIn the event of a fault, the outputs move to a defined (configurable) status.

Sensor Overrange / underrange Probe or lead short-circuit Probe or lead breakThermocouple • -- • Resistance thermometer • • •

Voltage 2…10V • • • 0…10V • -- --

Current 4…20mA • • • 0…20mA • -- --

• = recognized / -- = not recognized

Outputs

Relay (make) contact rating 3 A at 230 V AC resistive load

contact life 150.000 operations at rated load / 350,000 at 1A

Logic output 0/12 V / 30 mA max. (sum of all output currents)

ControllerController type continuous

Controller structures P/PD/PI/PID

A/D converter dynamic resolution up to 16-bit

Sampling time 250 ms

Electrical data Supply voltage (switchmode PSU) AC 110 … 240 V -15/+10%, 48 … 63 Hz

Electrical safetyacc. to DIN EN 61010, part 1

overvoltage category III, pollution degree 2 Power consumption Type 703041: max. 8 VA

Data backup EEPROM

Electrical connection

at the back, via screw terminals,, conductor cross-section up to max. 2,5 mm2

with core ferrules (length: 10 mm)

Conductor cross-sections and core-end ferrules for installationminimum cross-sectional

maximum cross-sectional

Min. length of core-end ferrule

without ferrule 0,34 mm2 2,5 mm2 10 mm (stripped)

Ferrule, no lip 0,25 mm2 2,5 mm2 10 mm

Ferrule, with lip up to 1,5mm2 0,25 mm2 1,5 mm2 10 mm

Ferrule, with lip above 1,5mm2 1,5 mm2 2,5 mm2 12 mm

Twin ferrule, with lip 0,25 mm2 1,5 mm2 12 mm

Electromagnetic compatibility DIN EN 61 326

Interference emission Classe B

Interference immunity to industrial requirements

Housing Housing type plastic housing for panel mounting to DIN 43700

Depth behind panel 90 mm

Ambient/storage temperature range 0 ... +55 °C / -30…+70 °C

Climatic conditions rel. humidity ≤ 90% annual mean, no condensation

Operating position horizontal

Protection acc. to DIN EN 60529, front IP 65, back IP 20

Weight (fully fitted) Typ 703041: ca. 220 g

Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

Page 6: Process controller - ARI Armaturen

6

Process controllerAccessories

Pressure transmitter MIDAS S05

Measuring ranges: 1 bar to 100 bar (relative pressure)1 bar to 25 bar (absolute pressure)

Pressure types: Relative or absolute pressure

Measuring system: Silicon sensor with stainless steel separating diaphragm

Accuracy levels: From 0,2% of final value of measuring range

Outputs: 4...20 mA, DC 0,5...4,5 V, DC 0...10 V, DC 1...5 V, DC 1...6 V

Temperatures of measured media: -40 ... +125 °C

Protection class acc. to DIN EN 60529:

Fixed cable (standard) - Measuring range IP66 (relative pressure) - Measuring range IP67 (absolute pressure)

Electrical connections: Round plug, M12 x 1

Pressure connections: Large number of threadsAreas of application: - HVAC (Heating, Ventitating and Airconditioning)

- Compressure construction- Packaging industry- Industrial pneumatic uses- Level

Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

Page 7: Process controller - ARI Armaturen

7Edition 03/12 - Data subject to alteration - Regularly updated data on www.ari-armaturen.com!

Process controllerCircuit diagram

Note

: If s

enso

rs ar

e clam

ped t

o ter

mina

ls 1 t

o 4, th

e 6,3

x32 m

m / 0

,05 A

mediu

m-slo

w mi

crofus

e for

the

curre

nt loo

p mus

t be r

emov

ed.

Limit v

iolati

onflo

ating

3 A

/ 230

V ou

tput

Sens

or br

eak

floati

ng 3

A / 2

30 V

outpu

t Analo

g outp

ut

- 4 ...

. 20 m

A Se

nsor

inpu

t for 4

...20 m

A cu

rrent

loop

+ 4 .

... 20

mA

Sens

or in

put fo

r 4...2

0 mA

curre

nt loo

p

6,3 x

32 m

m 24

V 0,

05 A

fuse

LED

lights

whe

n fus

e blow

s

Note

: Pr

otec

t the

pow

er in

put

with

a 6 A

fuse

!

ON-O

FF sw

itch

90°

Cut o

ff cab

les 5

+ 6 y

ellow

/ gre

en

Cove

r gro

und

Bina

ry inp

ut 2

Bina

ry inp

ut 1

4 x 0,

5 mm

2 o. y

ellow

/ gre

en

12 x

0,5 m

m2

0,5 mm2 core (red)

Page 8: Process controller - ARI Armaturen

Technik mit Zukunft.DEUTSCHE QUALITÄTSARMATUREN

ARI-ArmaturenAlbertRichterGmbH&Co.KG,D-33750SchloßHolte-Stukenbrock,Tel.+49(0)5207/994-0,Telefax+49(0)5207/994-297oder298Internet:http://www.ari-armaturen.comE-mail:[email protected]

8 Edition03/12-Datasubjecttoalteration-Regularlyupdateddataonwww.ari-armaturen.com!

Process controllerDimensions

Technology for the Future.G E R M A N Q U A L I T Y V A L V E S

ARI-ArmaturenAlbertRichterGmbH&Co.KG,D-33750SchloßHolte-Stukenbrock,Tel.+49(0)5207/994-0,Telefax+49(0)5207/994-297oder298Internet:http://www.ari-armaturen.comE-mail:[email protected]