PROCEDUREMPLS Aggregation Network

PTN

CONFIGURATION MANAGEMENT CSG&MASG

1 Document Control

Version History

This table shows a record of significant changes to the document.

Version Date Who Description of ChangeV1.0 2010-04-13 OUDDANI MustaphaV1.2 2010-06-23 DEVOS Marc LSR ID declaration

Contact Ericsson: Marc Devos Contact Mobistar : Mohamed Amraoui

2 CONFIGURATION CSG

2.1 Connection CSG

Step 1: Connect SHDSL links on the SHDSL Board of the CSG. Same for ADSL.

Step 2: Connect your PC on the ETH/OAM port of the CXPA Board with RJ45 cable

The following indicators are present on the front panel of the CXPA: STAT indicator, red or green, which indicates the board working status PROG indicator, red or green, which indicates the running status of the program SYNC indicator, red or green, which indicates the clock synchronization status SRV indicator, red, yellow or green, which indicates the service status CRIT indicator, red, which indicates critical alarms MAJ indicator, orange, which indicates major alarms MIN indicator, yellow, which indicates minor alarms LINK indicator, green, which indicates the port connection status ACT indicator, yellow, which indicates the data transceiving status of the port

Step 3: Start U 2000 server and after all the processes are started, start U2000 Web LCT

The default IP of NE PTN910 is 129.9.X.X/255.255.0.0Your laptop must have an IP on this range.In case that the PTN910 was already configured, be sure that you have an IP Address in its range.For U2000 Web LCT starts use the following:

User: adminPassword: admin123

Step 4: Click Auto Discovery NextThe system will start to search the NE

Step 5: When the NE is found Click stopCreate

The NE will be created on U2000LCT

Use the following:

User: lctPassword: password

Step 6: Click right on the NEConfigurationupload

The configuration of the NE will be uploaded on U2000LCT

Step 7: Click right NEOpen Slot Diagram

Click right on the SHDSL board and ADSL boardAdd physical board

Step 8: Click right NE NE explorer

Step 9: ConfigurationNE Attribute Modify NE IDEnter the values given by engineer

Step 10: Communication Communication ParametersConfigure the Management IP address

IP Address: Management IP of the CSGSubnet Mask: 255.255.224.0Gateway IP address: Management IP of the MASG (Primary GNE IP Address: 10.35.63.254)

You will loose the connectivity after configuring the management IP.You need to configure your laptop with an IP on the same range of the management IP.Then you can start to configure interface and management tunnel.

Step 11: Change the LSR ID

Function Tree -> Configuration -> MPLS Management -> Basic Configuration

Note: If the LSR ID is not blank, after you modify the LSRID the softwar of PTN910 will reboot. Wait until the PTN910 software startup completely, and then do the other configuration.

2.2 Configuration Interface

2.1.1 G.SHDSL Link

Step 1:Set G.shdsl bound mode is EFM

Interface Management—》DSL Interface—》G.shdsl Interfaces—Bound Mode

Step 2:Check G.shdsl link statusPort state = Data OKPort state = IDLE NOK

Interface Management—》DSL Interface—》G.shdsl InterfacesGenernal AttributesClick on “Query” button

Step 3:Set G.shdsl link port mode is Layer Mix

Interface Management—》Ethernet Virtual Interface—》Genernal Attributes

Step 4:Create sub-Interface on G.shdsl link

Interface Management—》Ethernet Virtual Interface—》Genernal Attributes—》NEW

Port : 50Name : Sub-1050Port Type : VLAN Sub interface

Board : Virtual PortPort : choose the port where the 4-SDH4 board is connected VLAN : 1050Specify IP Address: ManuallyIP address: set IP primary addressIP Mask : 255.255.254.0Enable tunnel : Enabled

Step 5:Check subInterface

Interface Management—》Ethernet Virtual Interface—》Layer 3 Attributes

2.2.2 ADSL Link

Step 1:Set ADSL link VPC list that include DSLAM VPC configuration

Interface Management—》DSL Interface—》ADSL Interfaces—》VPI/VPC Configuration—》Configure VPI/VCI

8/35 should be there

Step 2:Set ADSL link port mode is Layer MixInterface Management—》Ethernet Virtual Interface—》Genernal Attributes

Step 3:Creat subInterface on ADSL linkInterface Management—》Ethernet Virtual Interface—》Genernal Attributes—》NEW

Port : 51Name : Sub-1051Port Type : VLAN Sub interfaceBoard : Virtual PortPort : choose the port where the 3-ADS2A-1 is connected VLAN : 1051Specify IP Address: ManuallyIP address: set IP offload addressIP Mask : 255.255.254.0Enable tunnel : Enabled

Step 4:Check subInterface Interface Management—》Ethernet Virtual Interface—》Layer 3 Attributes

2.2 Configuration Management

Step 1:Create Static Route for IP TunnelConfiguration—》Control Plan Configuration—》Static Route Management —》Create

Two routes are needed:

Route List ID: 1 Board: Virtual EthernetPort: 50Next Hop IP Address: IP Primary of MASGDestination Node IP Address : IP Primary of MASGDestination Node Subnet Mask: 255.255.255.255

Route List ID: 2Board: Virtual EthernetPort: 50Next Hop IP Address: IP Primary of MASGDestination Node IP Address: LSR IP of MASGDestination Node Subnet Mask: 255.255.255.255

Step 2:Create LDP PeerConfiguration—》Control Plan Configuration—》MPLS-LDP Configuration —》Create

Opposite IP Address: LSR IP of MASG

Step 3:Create IP TunnelIP/GRE Tunnel Management—》IP Tunnel Management —》New

Tunnel ID : automaticSource Board: Virtual EthernetSource Port: 50Destination IP Address: IP Primary of MASG

Step 4:Enable IP Tunnel for DCN

Communication --》DCN Management —》Tunnel Settings—》IP Tunnel—》Enabled

3 CONFIGURATION MASG

3.1 Basic configuration

This part should be done during the commissioning

3.1.1 MASG NNI Side

Step 1:Set GE port mode is Layer MixInterface Management—》Ethernet Interface—》Port Mode

Step 2:Creat VLAN subinterface with IP MASG primary and offloadInterface Management—》Ethernet Virtual Interface—》General AttributesNew

Step 3:Check VLAN subinterfaceInterface Management—》Ethernet Virtual Interface—》Layer3 Attributes

3.1.2 UNI Side

Step 1:Change MASG GE port Attribute:Encapsulation Type :QinQ;MAX Frame Length:9000Function Tree—》Configuration—》Interface ManagementEthernet Interface—》General Attributes

Step 2:Change MASG GE port Layer 2 Attribute:Tag:81 00

Function Tree—》Configuration—》Interface ManagementEthernet Interface—》Layer 2 Attributes

Step 3:Create QinQ Link that means create S_VLAN we need:Function Tree—》Configuration—》Ethernet Service ManagementQinQ Link—》New

Step 4:Create E_Lan service that means add S_VLAN to service:Function TreeConfigurationEthernet Service ManagementE_Lan serviceNew

3.2 Configuration Management

Step 1:Create Static Route for IP TunnelConfiguration—》Control Plan Configuration—》Static Route Management —》Create

Two routes are needed:

Route List ID: follow the orderBoard: Virtual EthernetPort: 50Next Hop IP Address: IP Primary of CSGDestination Node IP Address : IP Primary of CSGDestination Node Subnet Mask: 255.255.255.255

Route List ID: follow the orderBoard: Virtual EthernetPort: 50Next Hop IP Address: IP Primary of CSGDestination Node IP Address: LSR IP of CSGDestination Node Subnet Mask: 255.255.255.255

Step 2:Create LDP Peer

Configuration—》Control Plane Configuration—》MPLS-LDP Configuration —》Create

Opposite IP Address: LSR IP of CSG

Step 3:Create IP TunnelIP/GRE Tunnel Management—》IP Tunnel Management —》New

Tunnel ID : AutomaticSource Board: Virtual EthernetSource Port: 50Destination IP Address: IP Primary of CSG

Step 4:Enable IP Tunnel for DCN (search by tunnel ID)Communication --》DCN Management —》Tunnel Settings—》IP Tunnel—》Enabled

4 CHECKING

4.1 ADD NE ON U2000

When the CSG and MASG is configured, you can ADD the CSG on NMS

Step 1: FileDiscoveryNE

Step 2: FileTransport NE search Add Select IP Address of GNEEnter IP Mngt of MASGClick OKStart search

Step 3: Click Stop when he found the NE ID of the CSGSelect the GNE ID (ID of MASG) and then create

When the NE is created: double-click on NEuploadThe configuration of CSG will be uploaded on the NMS. Then change the name of the CSG: ConfigurationAttribute

4.2 CHECK THE MANAGEMENT

Step 1 : Click right on the CSG and then login to check the management

Step 2 : Click right on the CSG on then do a ping to test the connectivity between the CSG and MASG

5 Backup/Recover Configuration

5.1 Backup Configuration

Step 1: Administration NE Software Management NE Data Backup/Restoration

Step 2: choose the NE to backup and click “backup”

You have all the backup history on “backup information”

5.2 Recover configuration

Step 1: Administration NE Software Management NE Data Backup/Restoration

Step2: choose NE to recover and click “Recover”

Step 3: Click Start and click Yes in the displayed Operation Confirmation dialog box. The processing information is displayed in the Device View area.NOTEWhen the restoration is complete, the following information will be displayed in the Device View area.

Step 4: Right-click the device icon and click Activation Database to activate the database file whichis just restored.