Ordering infOrmatiOn

CATALOG # C3 SYSTEM QTY

mrC3S01US naVigatiOn SYStem WitH iPad® 1/bOx

mrC3S02US naVigatiOn SYStem WitHOUt iPad® 1/bOx

Includes: (1) C3 manual (1) Charger base (1) Power Supply (1) Hub(1) eCg Snap Lead (1) iPad Case (Only for system with iPad)(1) remote

CATALOG # SYSTEM ACCESSORIES QTY

mrC3Sd90 Patient HUb 1/bOx

mrC3S91 remOte 1/bOx

mrC3S92 HUb batterY (aaa mediCaL grade) 1/bOx

mrC3S93 LabeL Printer 1/bOx

mrC3S95 iPad CaSe 1/bOx

mrC3S96 HUb CHarger baSe 1/bOx

mrC3S97 remOte batterY 1/bOx

mrC3S911 iPad POWer COrd 1/bOx

mrC3S915 C3 WaVe CaSe 1/bOx

mrC3S916 POLe mOUnt Kit fOr iPad 1/bOx

mrC3S94 POLe mOUnt fOr CHarger baSe 1/bOx

mrC3S920 HUb POWer COrd 1/bOx

mrC3S921 eCg Lead Set (USa) 1/bOx

mrC3rd000eCg CabLe aCCeSSOrY PaCK (eCg CLiP, remOte COVer & WindOW draPe)

12/bOx

mrC3rd001eLeCtrOdeS & PreP PadS aCCeSSOrY PaCK (eLeCtrOdeS, SKin PreP PadS)

25/bOx

mrC3rd003eCg CabLe aCCeSSOrY PaCK (eCg CLiP, remOte COVer)

25/bOx

mrC3rd004eCg CabLe aCCeSSOrY PaCK (max barrier draPe)

5/bOx

Pn2606-r rev. C 10/19

iPad® and apple® are registered trademarks

of apple inc.Medical Components, Inc. 1499 delp dr., Harleysville, Pa 19438, U.S.a. P: 215.256.4201 F: 215.256.1787 www.medcompnet.com

ECG Based Appfeaturing advanced, yet easy-to-use, software.

tHe innOVatOrS at medCOmP® are proud to introduce you to the next generation of eCg PiCC placement with the C3 Wave. the C3 Wave can now be used for tip confirmation as an alternative to x-ray. C3 Wave is an easy to use, app-based wireless eCg system designed to free up clini-cians hands by removing excess wires and allow-ing more focus on patient care.

Features & Benefits ➤ easy and intuitive from the very beginning

➤ easily correlate catheter depth with P wave activity

➤ Seamlessly transition between extracavitary and intracavitary waveforms

➤ intraprocedural system settings enable a stable and clear waveform

➤ Capture & compare multiple snapshots

➤ Store them all, but print or save to emr only what is necessary

wirElEss pAtiEnt huB

wirElEss rEmotE

ChArGinG BAsE

The use of Bluetooth technology eliminates the need to have cables running from the patient to the monitor.

www.medcompnet.com

C3 system integrationthe charging base was designed not only to charge the patient hub, but to offer additional functionality to meet the clinicians’ needs. the charging base allows the user to store all wireless components in one location. depending on preference, the charging base acts as a table top, or mounts to a pole. the two front spools allow the user to wrap the eCg leads when not in use. the remote is propped up to allow the user to easily place it in its sterile cover.

use ECG wirelessly the eCg waveform is wirelessly transmitted to a tablet which allows the operator to view and record changes to the eCg waveform as the tip of the catheter approaches the heart. as the PiCC approaches the atrium of the heart, the P wave in the eCg waveform shows substantial changes. this system is designed to aid the visualization of changes in P wave amplitude.

tm