Eclipse Node Installation and Commissioning FormsRev 2 June 06
Introduction
Purpose is to provide: A prompt for preparing data for new installations. A datapack for installers. A data entry form to capture additional as-built data. An as-built record with sign-off.
Associated forms included in this file are: Installation Inspection Form Customer Acceptance Form Remedial Action Form
Navigation: The Master Site Data column lists entries required. Click on a
‘+’ tab at the far left of the screen to open up required links andmodules for the Node. Click ‘–’ tab to close.
The Build / As-Built Data column is for data entry. Build data is data to be entered at the planning (datapack prep) stage. As-built data is data to be entered at site, mostly from Portal.
The Portal column highlights the data to be entered and data to be entered from Portal.
The Comments column is to capture any additional data.
See the Example Form for additional guidance.
Forms can be printed.
Important! Please provide feedback on the use of these forms. Feedback is needed to provide guidance on what improvements should be made to assist the application and usability of these forms. Please send feedback to:
Stratex Networks
Eclipse I+C Form: V1.3 June06 Commercial-In-Confidence 2
Eclipse Node Installation and Configuration Form For Site:
Installer: INUInstaller Contact Details:Scheduled Start Date:Scheduled Completion Date:New or Existing Site: INUeElectrical Supply OK yes/no:Site Grounding OK yes/no:Antenna Mounts OK yes/no:Site Security OK yes/no:Site Plans Included yes/no:
Master Site Data Comments
NodeNode Type INU or INUe ToNode Name ToSite Name ToSite Grid Reference ToTech Services contact details ToNOC contact detailsSite locationSite access See attached mapRack number/nameINU location in rackChassis serial number (All serial numbers begin with three letters)NCC serial numberFAN serial number(s)License serial number (Enter from NCC FlashCard label)Licensed capacityLicense capacity checked From-48Vdc power supply connection
NetworkingTerminal IP Address ToSubnet Mask ToStatic or dynamic routing ToStatic routing dataDHCP yes/no; address range ToTrap destinations To
Link 1
Link 2
Link 3
Link 4
DAC 16x
DAC 16x
DAC 4x
DAC 155o / 2x155o
DAC 2x155e
DAC ES
DAC GE
DAC 155oM
DAC 3xE3/DS3
DAC 3xE3/DS3M
Traffic CircuitsBus configuration ToCircuit connections ToCircuit naming To
AUX
NPC
Build / As-Built Data Portal Entry To /
Record
(Each circuit in a network should have a unique name, and that name should be entered at all Nodes that carry that circuit. Trib names should also relate to its circuit name to permit easy association of trib with circuit when setting a DAC BER test using the circuit loopback feature.)
General Instructions:
Slot Allocations1= 2= 3= 4= 5= 6= 7= 8= 9= 10=
To = Enter into Portal
From = Enter from Portal
Stratex Networks
Eclipse I+C Form: V1.3 June06 Commercial-In-Confidence 3
Date/Time(Specify Date/Time setting) To
BER Circuit Checks From
Alarms exit check Active alarms yes/no From
Ground checksSingle point bldg ground y/nMaster Ground Bar resistanceRack to MGB resistance-48V PSU to MGB resistanceTower ground resistance(s)Other resistance readingsMeter used
Hardware Installation completed
Name:Signature:Date:
Name:Signature:Date:
Completion Comments
Trib-trib BER check(Specify the tri/cct[s] and period)
Site Inspection Report completed yes/no
Node Installation & Tests completed
Stratex Networks
Eclipse I+C Form V1.3 June06 Commercial-In-Confidence 4
Eclipse Node Installation and Configuration Form
Installer: Joeseph Brown INUInstaller Contact Details: 021 362 700Scheduled Start Date: 10-Sep-05Scheduled Completion Date: 14-Sep-05New or Existing Site: Existing INUeElectrical Supply OK yes/no: YesSite Grounding OK yes/no: YesAntenna Mounts OK yes/no: YesSite Security OK yes/no: YesSite Plans Included yes/no: Yes
Master Site Data Comments
NodeNode Type INU or INUe INU ToTerminal Name E101 ToSite Name Lakeside ToSite Grid Reference Eastxxx Southxxx ToTech Services contact details 021 362 701 ToNOC contact details 021 362 702Site location 10km west of EkatahunaSite access Via Ridge road at first bridge See attached mapRack number/name 2BINU location in rack Directly under terminal E104Chassis serial number LES00934567 (All serial numbers begin with three letters)NCC serial number LEX00099997 FromFAN serial number(s) LER00094564License serial number SNI35435 FromLicensed capacity 40xE1 for slot 1, 40xE1 for slot 2.License capacity checked From
-48Vdc power supply connection
NetworkingTerminal IP Address 192.168.10.1 ToSubnet Mask 225.225.255.0. ToStatic or dynamic routing RIP 2 ToStatic routing data N/ADHCP yes/no; address range Yes, 192.168.10.2 to 192.168.10.10 ToTrap destinations N/A To
Link 1Link name/number Lakeside-Belmont ToRemote end site name Belmont ToRemote end node/terminal name E103 ToLocal antenna type(s) VHLP2-180-EXLocal antenna diameter(s) 0.6MAntenna serial number(s) AN35235Height on tower / pole mount ID 21M `Initial pointing (compass/map ref) 74 degreesPolarization VerticalProtected yes/no No ToProtection type N/A ToODU(s) direct mounting, yes/no YesODU type ODU 300hpODU serial number SNA7687988 FromODU cable length(s) required 35mLocation of RAC in INU Slot 1 ToRAC type RAC 30RAC serial number LEA00878770 FromTx frequency 17.85 GHz ToRx frequency 18.25 GHz ToT/R spacing 400 MHz ToTx power 17 dBm ToDetected forward power 17.1 dBm FromCapacity 32xE1 ToModulation 16QAM To
For Site: Lakeside
Build / As-Built Data Portal Entry To /
Record
40xE1 for slot 1, 40xE1 for slot 2.10xE1 for slots 3 & 4.
Provide and install 12A Cct Breaker on supply panel at top of rack
General Instructions: 4-wheel drive access only. This time of the year the track will be wet and slippery. Please do a battery check and run the back-up diesel generator for about 30 mins and check associated panel lights. Should all be green.
Slot Allocations1= RAC 302= RAC 303= Aux4= DAC 16x5= 6= 7= 8= 9= 10=
To = Enter into Portal
From = Enter from Portal
Stratex Networks
Eclipse I+C Form V1.3 June06 Commercial-In-Confidence 5
Master Site Data CommentsBuild / As-Built Data Portal Entry To /
Record
ATPC yes/no No ToATPC dataExpected RSL -51 dBmIndicated RSL -50 dBm FromExpected RSSI 1.25Indicated RSSI 1.27 FromExpected fade margin 35 dBMeasured fade margin 37 dB FromG.826 link check Zero errors over 14 hours FromAlarms check No active alarms from Link 1 FromPerformance check All indications normal FromLink 1
Link 2Link name/number Lakeside to Pine Hill ToRemote end site name Pine Hill ToRemote end node/terminal name E102 ToLocal antenna type(s) VHLP2-180-EXLocal antenna diameter(s) 0.6MAntenna serial number(s) SN12495Height on tower / pole mount ID 21MInitial pointing (compass/map ref) 178 degreesPolarization VerticalProtected yes/no No ToProtection type N/A ToODU(s) direct mounting, yes/no YesODU type ODU 300hpODU serial number SNBO93859 FromODU cable length(s) required 38mLocation of RAC in INU Slot 2 ToRAC type RAC 30RAC serial number LEN00243551 FromTx frequency 17.95 GHz ToRx frequency 18.35 GHz ToT/R spacing 400 MHz ToTx power 22dBm ToDetected forward power 21.5 dBm FromCapacity 32xE1 ToModulation 16QAM ToATPC yes/no No ToATPC dataExpected RSL -53 dBmMeasured RSL -52 dBm FromExpected RSSI 1.3vIndicated RSSI 1.35v FromExpected fade margin 33 dBMeasured fade margin 32 dB FromG.826 link check Zero errors over 14 hours FromAlarms check No active alarms from Link 2 FromPerformance check All indications normal FromLink 2
Link 3
Link 4
DAC 16xDAC location in INU Slot 4 ToSerial number LEX00234567 FromE1 or DS-1 E1 ToBal or Unbal Unbal To DS1 encoding N/A To DS1 line length N/A ToPort / trib names Lak 1 to 8 ToConnect to Rack BNC panel: ports 1 to 8DAC 16x
DAC 16x
DAC 4x
DAC 155o / 2x155o
DAC 2x155e
Stratex Networks
Eclipse I+C Form V1.3 June06 Commercial-In-Confidence 6
Master Site Data CommentsBuild / As-Built Data Portal Entry To /
Record
DAC ES
DAC GE
DAC 155oM
DAC 3xE3/DS3
DAC 3xE3/DS3M
Traffic CircuitsBus configuration E1 ToCircuit connections To
Circuit naming To
AUXAUX location in INU Slot 3 ToSerial number LEA05090295 FromAuxiliary ports
Data, sync, P1, default, Aux Bel/Lak To
To
To
Auxiliary portsAuxiliary circuitsPort 1: to/circuit name Port 1 to Link 1 port 1, Bel/Lak ToPort 1: to/circuit name ToPort 1: to/circuit name ToAuxiliary circuits ToAlarm I/OPort layout 4xin, 2xout ToPort 1, type, active condition Digital input, active high To
Port 2, type, active condition ToPort 3, type, active condition ToPort 4, type, active condition ToPort 5, type, active condition ToPort 6, type, active condition ToAlarm I/OAlarm actions
To
To
To
To
To
Alarm actionsAUX
NPC
Date/Time(Specify Date/Time setting) Sync to Portal PC Date/Time To
BER Circuit ChecksFrom
Alarms exit check Active alarms yes/no No active alarms From
Link 1 ports 1-8 to DAC 16x, slot 4, ports 1-8.Link 1 ports 9 to 32 to Link 2, slot 2, ports 1 to 24.
Link 1 ports 1-8: Bel/Lak 1 to Bel/Lak 8.Link 1 ports 9-24: Bel/Pin 1 to Bel/Pin 16.Link 1 ports 25-32: Bel/Wel 1 to Bel/Wel 8.
Port 1: function, type, port settings, name
Port 2: function, type, port settings, name
Port 3: function, type, port settings, name
Wire to intruder alarm: alarm is active when circuit is broken.
Destination IP address, slot, and output. Trigger(s).
192.168.2.1, slot 4, output 1.AUX alarm input 1.
At commissioning check that the destination output (bell) at Belmont activates when the intruder alarm is activated. Also check that the alarm event is raised at the NOC.
Destination IP address, slot, and output. Trigger(s).
Destination IP address, slot, and output. Trigger(s).
Destination IP address, slot, and output. Trigger(s).
Destination IP address, slot, and output. Trigger(s).
Trib-trib BER check(Specify the trib/cct[s] and period)
BER check completed on trib 1 Lakeside to Belmont.
Tribs from Belmont through to Pine Hill will be checked during Pine Hill commissioning.
Stratex Networks
Eclipse I+C Form V1.3 June06 Commercial-In-Confidence 7
Master Site Data CommentsBuild / As-Built Data Portal Entry To /
Record
Ground checksSingle point bldg ground y/n YesMaster Ground Bar resistance 0.62 ohmsRack to MGB resistance 0.15 ohms-48V PSU to MGB resistance 0.27 ohmsTower ground resistance(s)
Other resistance readingsMeter used Prova clamp-on, model DX Serial number 00458
Yes. Attached.
Hardware Installation completed
Name: Joe BrownSignature:Date: 14 September 2005
Name: Joesphine BrownSignature:Date: 14 September 2005
Completion Comments The second farm gate is almost off its hinges.One of the two tower-top warning lights is out.Diesel generator checked out OK
Not possible to measure. Cannot get meter jaws around the ground straps.
Site Inspection Report completed yes/no
Node Installation & Tests completed
Stratex Networks
Inst. Insp. Report: V1.2 Mar04 Commercial-In-Confidence 8
Eclipse Node Installation Inspection Report For Site:
Check for correct and complete installation of:
Item Pass Fail Comments
Antenna Mounting
Antenna side support (if used)
ODU fastening
ODU grounding
ODU connector weatherproofing
ODU cable fastening
ODU cable grounding
Lightning surge suppressor(s)
RAC to surge suppressor jumper cable
INU location in rack
INU is labelled (if required)
INU grounding
INU power supply wiring
INU cards are correctly secured
Unused slots have blank plates fitted
Trib cables are correctly and neatly installed
Trib cables are numbered (if required)
Alarms all-clear
Site left clean and tidy
Site photos taken (if required)
Site ground measurements (if required)
Checked by:
Name:
Signature:
Date:
Additional Comments:
Stratex Networks
Acceptance Form V.1.2 Mar04 Commercial-In-Confidence 9
Eclipse Node Customer Acceptance Form
Site Name:
Eclipse Node Name:
Related documents Received Yes/No
Eclipse Installation and Commissioning Form:
Eclipse Installation Inspection Report:
Acceptance Category* Category
Accepted / Conditionally Accepted / Not Accepted:
Signed By:
Customer
Name:
Signature:
Title:
Date:
Stratex Networks
Name:
Signature:
Title:
Date:
*If conditionally accepted or not accepted, the action required to achieve acceptance must be detailed in a Remedial Action Form
Stratex Networks
Acceptance Form V.1.2 Mar04 Commercial-In-Confidence 10
Stratex Networks
Remedial Action Form V1.2 Mar04 Commercial-In-Confidence 11
Eclipse Node Remedial Action Form
Site Name:
Eclipse Node Name:
Item No. Description of Remedial Action Required Responsibility
Signed As Completed
Customer
Name:
Signature:
Title:
Date:
Stratex Networks
Name:
Signature:
Title:
Date: