Post on 03-Jul-2020
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
Baugruppen / assemblies
A 1 Gehäuse - housing
B 2 Außenleiter - outer conductor
C 2 Isolierteil - insulator
D 2 Kontakt-Pin - contact pinEinzelteile / single parts
E 2 Kabel - cable
F 2 Dichtung - seal
G 2 Abdeckkappe - cap
H 2 Stützhülse - carrying tube
I 2 Schutzkappe - protective cap
---
---
4:5 (1:2) --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 1 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
Gesamtbaugruppe HPKassembly HPK
Einzel-Baugruppensubassembly overview
Farbdarstellung muss nicht den Bauteilen entsprechen.Colors are not necessarily corresponding with parts.
EG
F
HA
B
1:2
D
C
I
A
C
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
Zuschnittzugabe Kabellänge
cable length
350+50
Zuschnittzugabe für Adapterplatten / Adding blank for adaptor platesKabelquerschnitt
Wire Size(mm²)
Herstellermanufacturer
Teile-Nummerpart number
ZuschnittzugabeAdding blank
( 1mm)16 Coroplast FHLR2GCB2G 16 mm² 45
25Coroplast FHLR2GCB2G 25 mm² 45Kroschu FHLALR2GCB2G 25 mm² 45
35Coroplast FHLR2GCB2G 35 mm² 45Kroschu FHLALR2GCB2G 35 mm² 45
Leoni FHLR2GCB2G 35 mm² 45
50
Coroplast FHLR2GCB2G 50 mm² 45Kroschu FHLALR2GCB2G 50 mm² 45
Leoni FHLR2GCB2G 50 mm² 45Huber und Suhner FHLR4GC13X 50mm² 45
---
---
4:5 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 2 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
1) Kabel "E" auf Länge schneiden / Cut cable "E" into length Zuschnittzugabe für Kuppler / Adding blank for jack
2) Abdeckkappe "G" und Dichtung "F" auf Kabel "E" montieren. Slide cap "G" and seal "F" on cable "E".
E
adding blank
G F E
400
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
Y Schirmschnitt
Z Mantelschnitt
Abstand
KabelquerschnittWire size
(mm²) LV_216-1Teile-Nummerpart number
Z*mm
( 0.5)
Y*mm
( 0.5)16 FHLR2GCB2G 16 mm² 21.5 10.5
25 FHLR2GCB2G 25 mm² 21.5 10.5FHLALR2GCB2G 25 mm² 20.5 9.5
35 FHLR2GCB2G 35 mm² 21.5 10.5FHLALR2GCB2G 35 mm² 20.5 9.5
50FHLR2GCB2G 50 mm² 21.5 10.5
FHLALR2GCB2G 50 mm² 20.5 9.5FHLR4GC13X 50mm² 21.5 10.5
Teile-Nummerpart number
Abstand*spacing
(mm 0.5)FHLR2GCB2G 16 mm² 20.75FHLR2GCB2G 25 mm² 20.75
FHLALR2GCB2G 25 mm² 20.75FHLR2GCB2G 35 mm² 20.75
FHLALR2GCB2G 35 mm² 19.75FHLR2GCB2G 50 mm² 20.75
FHLALR2GCB2G 50 mm² 19.75FHLR4GC13X 50mm² 20.75
---
---
1:2 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 3 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
3) Mantel (Z) und Schirm (Y) von Kabel "E" nach Tabelle abisolieren. Insulate coat (Z) and shielding (Y) of cable "E" acc. to table.
4a) Stützhülse "H" auf Kabel "E" aufschieben. Orientierung der Stützhülse beachten. Schirmgeflecht muss flach anliegen und darf nicht zerstört werden. Abstand nach Tabelle. Move carrying tube "H" on cable "E". Observe orientation of carrying tube Make sure the braided shielding is flat and is not destroyed. For spacing see table.
4b) Schirmfolie entfernen Remove shielding foil
* Prozessbedingte Abweichungen der Abisoliermaße, z.B. durch Schweißen (Längung, Einlegetiefe), sind zulässig und auszugleichen process-related differences of stripping dimensions e.g. by welding (elongation, insertion depth) are allowed and have to corrected
E
shielding cut
insulate jacked cut
HE spacing
400
400
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
Schnitt Dielektrikum X
max. 15
Teile-Nummerpart number
X*(mm)
( 0.5)FHLR2GCB2G 16 mm² 12FHLR2GCB2G 25 mm² 12
FHLALR2GCB2G 25 mm² 12FHLR2GCB2G 35 mm² 12
FHLALR2GCB2G 35 mm² 12FHLR2GCB2G 50 mm² 12
FHLALR2GCB2G 50 mm² 12FHLR4GC13X 50mm² 12
---
---
1:1 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 4 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
5) Schirmgeflecht gleichmäßig über Stützhülse "H" umlegen. Überlappung min. 70%. Nicht auskämmen. Move the braided shielding equally over carrying tube "H". Overlap min. 70%. Do not comb out the wire.
6) Isolierung (X) nach Tabelle abisolieren. Remove insulation (X) acc. to table.
* Prozessbedingte Abweichungen der Abisoliermaße, z.B. durch Schweißen (Längung, Einlegetiefe), sind zulässig und auszugleichen process-related differences of stripping dimensions e.g. by welding (elongation, insertion depth) are allowed and have to corrected
H
dielectricum cut X300
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
min. 6
W
V
W
Teile-Nummerpart number
"W" Winkel-abweichung
angle deviationmax.
Kontrollmass nachSchweißencontrol after
weldingV mm (+1
-0.5)
FHLR2GCB2G 16 mm² 3° 49.0FHLR2GCB2G 25 mm² 3° 50.5
FHLALR2GCB2G 25 mm² 3° 50.5FHLR2GCB2G 35 mm² 3° 50.5
FHLALR2GCB2G 35 mm² 3° 50.5FHLR2GCB2G 50 mm² 3° 51.0
FHLALR2GCB2G 50 mm² 3° 51.0FHLR4GC13X 50mm² 3 51.0
---
---
1:1 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 5 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
7) Kabeldielektrikum abziehen, Kabelinnenleiter "E" an Kontakt-Pin "D" anschweißen nach RN_087-14. Winkelabweichung beachten! Remove cable dielectric, weld cable inner conductor "E" to contact pin "D" acc. to RN_087-14. Note angular deviation!
E D
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
35+0.2-0.2
---
---
4:5 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 6 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
8) Kunststoffgehäuse "A " auf Kabel "E" montieren. Gehäuseausrichtung und Pinbelegung beachten! Mounting plastic housing "A " on cable "E". Observe plastic housing orientation and pin assignment!
9) Isolierteil "C " auf Anschlag in Außenleiter "B" montieren. Kontrolle der Verrastung. Kontrolle Isolierteil "C " im Außenleiter "B" frei drehbar. Mount insulator "C " into the outer contact "B". Control of locking. Control that insulator "C" is freely rotatable in the outer conductor "B".
A E
B C
400
A A
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
(19.7)
---
---
4:5 (1:2) --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 7 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
10) Innenleiterbaugruppe bis Anschlag in Aussenleiterbaugruppe einschieben. Kontrolle der Verrastung. Pinbelegung beachten! Insert center contact assembly into the outer contact assembly. Control of locking. Observe pin assignment!
Kodierung BCoding B
Kodierung CCoding C
Gemessen mit Messwerkzeug H4W025-000measured with tool H4W025-000
1:22
1
2
1
2
1
2
1
1:2
Optional / Optional
A-A
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
CH
CB
Crimpbereich
0+0.5
1+0.5-0.5
KabelquerschnittWire Size
(mm²)Hersteller / Werkzeugnummer
manufacturer part numberCBmm
( 0.2)
CHmm
( 0.1)
Auszugskrafttensile strength
min. (N)
16Hanke
925-06287-301-xxx*926-06287-301-xxx**
18.90 18.90 150
25Hanke
925-06287-301-xxx*926-06287-301-xxx**
18.90 18.90 300
35Hanke
925-06287-301-xxx*926-06287-301-xxx**
18.90 18.90 300
50Hanke
925-06902-301-xxx*926-06902-301-xxx**
20.85 20.85 300
---
---
7:10 ( ) --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 8 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
11) Vor dem Crimpen darauf achten, dass der Innenleiter "D" in dem Isolierteil "C" eingerastet ist. Die Stützhülse "H" muss vollständig innerhalb des Crimpbereiches liegen. Before crimping make sure, that inner conductor "D" is locked into the insulator "C". Ensure that carrying tube "H" is completely inserted into the crimping area.
Außenleiter "B" crimpen.Crimp outer conductor "B"
* Einlegen von rechts / engaged from right** Einlegen von vorn / engaged from front
1:1crimping area
B C
A-A2:1
Außenleiter "B"outer contductor "B"
Stützhülse "H"carrying tube "H"
400
200
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
---
---
1:1 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 9 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
12) Litzen dürfen nicht überstehen! Überstehende Litzen müssen entfernt werden! Wires must not overlap! Supernatant wires must be removed!
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
69+0.4-0.4
---
---
1:1 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 10 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
13) Außenleiterbaugruppe bis zum Anschlag in Gehäuse "A" einschieben. Kontrollmass beachten! Install outer conductor assembly until stop into housing "A". Check dimension!
A
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
---
---
1:1 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 11 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
14) Abdeckkappe "G" und Dichtung "F" bis Gehäuseaussenkante in Gehäuse "A" einschieben. Slide cap "G" and seal "F" into housing "A" until stop.
Orientierung beachten. Abdeckkappe "G" einrastenNote orientation. Snap cap "G" into place
G
FA
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
---
---
1:1 --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 12 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
Endzustand Konfektionierter Stecker
final condition Pre-wired plug
15) (optional / optional) Schutzkappe "I " auf konfektionierten Stecker montieren. Mount protective cap "I " on pre-wired plug.
I
400
scale:
title:
drawing-no.:
ISO
-Pro
jekt
ion
Met
hode
1
series:
assembly instr.:
panel piercing:
crimpinsert:cable:
PD_F
B_01
generaltolerance
1 2 3 4
A
B
C
D
E
F
A
B
C
D
E
F
1 2 3 4
-MET
RIC
-
AaBbCcDdEeFfGgHhIiJjKkLlMmNnOoPpQqRrSsTtUuVvWwXxYyZzÄäÖöÜüß1234567890
vertraulich / confidential
© R
OSE
NBE
RG
ER H
OC
HFR
EQU
ENZT
ECH
NIK
GM
BH &
Co.
KG
or T
HIR
D P
ARTY
The
repr
oduc
tion,
dis
tribu
tion
and
utiliz
atio
n of
this
doc
umen
t as
wel
l as
the
com
mun
icat
ion
of it
s co
nten
ts to
oth
ers
with
out e
xpre
ss a
utho
rizat
ion
by th
e ow
ner o
r rig
hts-
hold
er is
pro
hibi
ted.
Offe
nder
s ca
n be
hel
d lia
ble.
All
right
s re
serv
ed in
the
even
t of t
he g
rant
of p
aten
t, ut
ility
mod
el o
r des
ign.
---
---
4:5 (1:1) --- --- ---
--- ---
Montageanleitung 2-Pol HPK 16-50mm²assembly instruction 2-pol HPK 16-50mm²
. .
MA_HV0105 sheet: 13 of: 13
remarks: . rev. change-no name date100 18-0862 T_Pscheiden 30.05.2018200 18-1282 S_Keiner 25.07.2018300 18-1600 M2_Mamou 30.08.2018400 19-2256 U_Chung 05.12.2019
appr. 05.12.2019 C_Hartensteicheck. 05.12.2019 M_Hellwigdrawn 16.05.2018 T_Pscheiden
date name
Zust. / Rev. Änderung / Change200 -min. Abzugskraft Schritt 11 von Laborangaben zu LV215
step 11 min. tensile strength from laboratory information to LV215300 -Schitt Dielektrikum :länge X von 11 auf 12
Dielectricum cut :length X from 11 to 12400 -Huber und Suhner Kabel hinzugefügt
Huber and Suhner cable added -Generaltoleranz gelöschtgeneral tolerance removed