FLEX ENERGY STORAGE SYSTEMTM BMT-ESS2KW/5KWH/R

Nominal Input/Output VoltageAC FrequencyMax. AC Input CurrentMax. AC Continuous Output CurrentMax. AC Continuous Output PowerDC Charging Range

120Vac 1F50/60Hz

22.7 A ac16.7 A ac

2000VA/1600W48-54Vdc

Safety CertificationCell TypeNominal VoltageMaximum CapacityTotal Battery Power CapacityOver voltage Detecting pointUnder Voltage Detecting PointMax. Charging CurrentMax. Discharging Current

UL1973LiFePO4 / Lithium-ion Battery (UL certified)

51.2Vdc100Ah

5120Wh54.25 Vdc47.25 Vdc

30A40A

Safety CertificationOperating Temperature RangeStorage temperature

UL17410°C to 55°C-15°C~ 60°C

BATTERY ENERGY STORAGE (BMT-ES5000R)

GENERAL SPECIFICATIONS:

GENERAL SPECIFICATIONS:Nominal Input VoltageMax. Input CurrentMax. Input Branch Circuit overcurrent protectionMin. Interrupting Rating of DC overcurrent protectionRated Output PowerOutput Power FactorOutput Phase ConfigurationOutput Voltage WaveformNominal Output VoltageOutput FrequencyOutput CurrentMax. Output Branch Circuit overcurrent protection

48Vdc33A

50 A dc10 KA

2000VA/1600W0.8

Single PhasePure Sine Wave

120Vac 1F50/60Hz16.7A ac30 A ac

INVERTER MODE:

System VoltageMax. Solar Voltage (Open circuit voltage)Range of Input VoltageMax. Input Branch Circuit overcurrent protectionMin. Interrupting Rating of DC overcurrent protectionDC Charging VoltageMax. Input CurrentMax. Input Short Circuit Current

145Vdc145Vdc

60 ~115Vdc80 A dc

10 KA48Vdc

45 A50A

SOLAR CHARGER MODE:

AC Input /Output RatingAC Input /Output CurrentAC FrequencyRelay Response timeOperating Temperature

120Vac, 50~60HZ15A

50/60Hz10msec

0°C~45°C

AUTOMATIC TRANSFER SWITCH (BMT-ATS20)

CONTROL UNIT INVERTER (BMT-CU2000R)

Max. Solar Voltage (Open circuit voltage)Range of DC PV Input VoltageMax. PV Input CurrentBattery CapacityAmbient Temperature RangeEnvironmental Rating

145Vdc60 ~115Vdc

45 A5120WH

0°C~ 45°CIn-door use, IP20

Battery Serial/Parallel numberOver Temperature Detecting PointCharging TemperatureDischarging Temperature

16S/2P70°C

0~+45°C-10~+50°C

Control UnitBattery Energy Storage (X2)Automatic Transfer Switch

Control UnitBattery Energy Storage (X2)Automatic Transfer Switch

DIMENSIONS WEIGHT

U L F i l e N u m b e r : E 4 9 1 0 6 8A S S E M B L E D I N U S A

6” x 12” x 19”27.5” x 13.5” x 8.3”

10” x 10” x 4”

25.4 lbs132.3 lbs

8.2 lbs

Control UnitBattery Energy Storage (X2)Automatic Transfer SwitchCombiner Box

Control UnitBattery Energy Storage (X2)Automatic Transfer SwitchCombiner Box

DIMENSIONS WEIGHT

U L F i l e N u m b e r : E 4 9 1 0 6 8A S S E M B L E D I N U S A

Energy Storage NumberEnergy Storage Nominal VoltageEnergy Storage Maximum CapacityDC VoltageDC CurrentTotal Battery Power CapacityAmbient Temperature Range

COMBINER BOX (BMT-CNR2-R)AUTOMATIC TRANSFER SWITCH (BMT-ATS20)

2 BATTERY OPTION: FLEX ENERGY STORAGE SYSTEMTM

Nominal Input/Output VoltageAC FrequencyMax. AC Input CurrentMax. AC Continuous Output CurrentMax. AC Continuous Output PowerDC Charging Range

120Vac 1F50/60Hz

22.7 A ac16.7 A ac

2000VA/1600W48-54Vdc

Safety CertificationCell TypeNominal VoltageMaximum CapacityTotal Battery Power CapacityOver voltage Detecting pointUnder Voltage Detecting PointMax. Charging CurrentMax. Discharging Current

UL1973LiFePO4 / Lithium-ion Battery (UL certified)

51.2Vdc100Ah

5120Wh54.25 Vdc47.25 Vdc

30A40A

Safety CertificationOperating Temperature RangeStorage temperature

UL17410°C to 55°C-15°C~ 60°C

BATTERY ENERGY STORAGE X2 (BMT-ES5000R)

GENERAL SPECIFICATIONS:

GENERAL SPECIFICATIONS:Nominal Input VoltageMax. Input CurrentMax. Input Branch Circuit overcurrent protectionMin. Interrupting Rating of DC overcurrent protectionRated Output PowerOutput Power FactorOutput Phase ConfigurationOutput Voltage WaveformNominal Output VoltageOutput FrequencyOutput CurrentMax. Output Branch Circuit overcurrent protection

48Vdc33A

50 A dc10 KA

2000VA/1600W0.8

Single PhasePure Sine Wave

120Vac 1F50/60Hz16.7A ac30 A ac

251.2Vdc

100Ah54.25Vdc

35A5120Wh X20°C~45°C

INVERTER MODE:

System VoltageMax. Solar Voltage (Open circuit voltage)Range of Input VoltageMax. Input Branch Circuit overcurrent protectionMin. Interrupting Rating of DC overcurrent protectionDC Charging VoltageMax. Input CurrentMax. Input Short Circuit Current

145Vdc145Vdc

60 ~115Vdc80 A dc

10 KA48Vdc

45 A50A

SOLAR CHARGER MODE:

AC Input /Output RatingAC Input /Output CurrentAC FrequencyRelay Response timeOperating Temperature

120Vac, 50~60HZ15A

50/60Hz10msec

0°C~45°C

6” x 12” x 19”27.5” x 13.5” x 8.3”

10” x 10” x 4”3.3” x 5.5” x 11.3”

25.4 lbs132.3 lbs

8.2 lbs4.0 lbs

CONTROL UNIT INVERTER (BMT-CU2000R)

Max. Solar Voltage (Open circuit voltage)Range of DC PV Input VoltageMax. PV Input CurrentBattery CapacityAmbient Temperature RangeEnvironmental Rating

145Vdc60 ~115Vdc

45 A5120WH

0°C~ 45°CIn-door use, IP20

Battery Serial/Parallel numberOver Temperature Detecting PointCharging TemperatureDischarging Temperature

16S/2P70°C

0~+45°C-10~+50°C