Post on 20-Mar-2018
Build Fast. Build Green. Build Hebel.
- Up to 4 times lighter than concrete- Recyclable, inert, non-toxic- Structural & fire resistant building block- Thermal insulator; reduces thermal bridging- Sound insulator up to STC 50- Improves building operating costs- Contractor-friendly installation
F E A T U R E S & B E N E F I T S
Block
- Residential - Commercial - Manufacturing - School & Public - Heathcare
A P P L I C A T I O N S
manufactured by:HBDS-2010
Rev. 6.15.14
hebel-usa@xella.com
Hebel Block Nominal Dimensions
Material Properties
Mortar
AAC-2/400 AAC-4/500 AAC-4/600
*LEED Credits
*All credits are subject to USGBC interpretation and the appropriate use on the specific building project.
Physical Data / Footnotes
Product Literature: Data Sheet HBDS-2010, ASTM C 1386Mortar: Thick-Bed Mortar ASTM C 270 (3/4” max) Thin- Bed Mortar ASTM C 1660Finishes: Plaster, Stucco, Paint w/ perm rating >5 (ASTM C 1692, 9.2)Other Finishes: Tile, Thin Stone/Brick, Spray-on Siding, Acrylic, Drywall (furred out) See Technical Manual and / or Coating Manufacturers recommendations
Footnotes: 1. Hebel Product is not suitable for ground contact applications where water and freezing are possible.
2. Proper dust protection is recommended when cutting Hebel.
Ancillary Products Reference
EA Prereq 2EA Credit 1
MR Credits1.1, 2, 5
EQ Credit 4.6 ID Credits EA1, MR2, MR5
24”
8”
1”, 2”, 3”, 4”, 6”, 8”, 10”, 12”
38 44
524437
30
32 3725
195 296
0.25
0.80 0.92 1.03
6.52 5.83
10.00
7.50
12.50 10.90
15.00 13.04 11.65
9.71
7.778.70
n/a n/a42
4Hr 4Hr4Hr
4Hr 4Hr4Hr
4Hr 4Hr4Hr
4Hr 4Hr4Hr
n/a n/a46
n/a n/a48
n/a n/an/a
Thickness:
Height:
Length:
Compressive Strength (psi)
Dry Bulk Density (pcf)
Design Density (pcf)
Shipping Density (pcf)
Modulus of Elasticity (ksi)
Specific Heat
Thermal Conductivity (Btu in/h ft² °F)
Thermal Resistance (h ft² °F/Btu)
6”
8”
10”
12”
Sound Transmission Class (db)
6”
8”
10”
12”
UL CertificationsFire Rating: ANSI / UL 263
Design No. U916 (min 8” Block)
Design No. U917 (min 6” Block)
Design No. U919 (min 4” Block)
Design No. U921 (min 6” Block)
Thick Bed Mortar ASTM C270 (base = 3/4” max.)
Thin Bed Mortar ASTM C1660
Energy & Atmosphere Materials & Resources Indoor Environment Quality Innovations in Design
290 580
HJBDS-2010 Hebel Jumbo / Mini JumboHUBDS-2010 Hebel U-BlockHCBDS-2010 Hebel Cored BlockHLBDS-2010 Hebel Lintel BlockHM-2010 Hebel MortarHT-2010 Hebel Tools
To order samples or literature, contact customer service at:
T
H
L
Xella ® and Hebel ® are registered trademarks of the Xella Group.
Toll Free:
T:F:
1-888-SA-XELLA (72-93552)Xella Aircrete North America, Inc.900 Schneider Dr.Cibolo, Texas 78108210/402-3223210/402-6390
Build Fast. Build Green. Build Hebel.
Cored Block
- Up to 4 times lighter than concrete- Recyclable, inert, non-toxic- Structural & fire resistant building block- Thermal insulator; reduces thermal bridging- Sound insulator up to STC 50- Improves building operating costs- Contractor-friendly installation
F E A T U R E S & B E N E F I T S
- Residential - Commercial - Manufacturing - School & Public - Heathcare
A P P L I C A T I O N S
manufactured by:HCBDS-2010
Rev. 6.15.14
Hebel Cored Block Nominal Dimensions
Material Properties
Mortar
AAC-2/400 AAC-4/500 AAC-4/600
*LEED Credits
*All credits are subject to USGBC interpretation and the appropriate use on the specific building project.
Physical Data / Footnotes
Ancillary Products Reference
Product Literature: Data Sheet HCBDS-2010, ASTM C 1386Mortar: Thick-Bed Mortar ASTM C 270 (3/4” max) Thin- Bed Mortar ASTM C 1660Finishes: Plaster, Stucco, Paint w/ perm rating >5 (ASTM C 1692, 9.2)Other Finishes: Tile, Thin Stone/Brick, Spray-on Siding, Acrylic, Drywall (furred out) See Technical Manual and / or Coating Manufacturers recommendations
Footnotes: 1. Hebel Product is not suitable for ground contact applications where water and freezing are possible.
2. Proper dust protection is recommended when cutting Hebel.
Energy & Atmosphere Materials & Resources Innovations in Design
HJBDS-2010 Hebel Jumbo / Mini JumboHUBDS-2010 Hebel U-BlockHBDS-2010 Hebel BlockHLBDS-2010 Hebel Lintel BlockHM-2010 Hebel MortarHT-2010 Hebel Tools
8”
8”, 10”, 12”
38 44
524437
30
32 3725
195 296
0.25
0.92 1.03
n/a n/an/a
4Hr 4Hr4Hr
4Hr 4Hr4Hr
4Hr 4Hr4Hr
4Hr 4Hr4Hr
n/a n/a46
n/a n/a48
n/a n/an/a
Thickness:
Height:
Length:
Compressive Strength (psi)
Dry Bulk Density (pcf)
Design Density (pcf)
Shipping Density (pcf)
Modulus of Elasticity (ksi)
Specific Heat
Thermal Resistance (h ft² °F/Btu)
6”
8”
10”
12”
Sound Transmission Class (db)
6”
8”
10”
12”
UL CertificationsFire Rating: ANSI / UL 263
Design No. U916 (min 8” Block)
Design No. U917 (min 6” Block)
Design No. U919 (min 4” Block)
Design No. U921 (min 6” Block)
Thick Bed Mortar ASTM C270 (base = 3/4” max.)
Thin Bed Mortar ASTM C1660
290 580
n/a n/a
10.00
n/a
12.50 10.90
15.00 13.04 11.65
9.71
7.778.70
0.80Thermal Conductivity (Btu in/h ft² °F)
Indoor Environment Quality
24”
EA Prereq 2EA Credit 1
MR Credits1.1, 2, 5
EQ Credit 4.6 ID Credits EA1, MR2, MR5
T
H
L
To order samples or literature, contact customer service at:
Xella ® and Hebel ® are registered trademarks of the Xella Group.
Toll Free:
T:F:
1-888-SA-XELLA (72-93552)Xella Aircrete North America, Inc.900 Schneider Dr.Cibolo, Texas 78108210/402-3223210/402-6390
hebel-usa@xella.com
Build Fast. Build Green. Build Hebel.
U Block
- Up to 4 times lighter than concrete- Recyclable, inert, non-toxic- Structural & fire resistant building block- Thermal insulator; reduces thermal bridging- Sound insulator up to STC 50- Improves building operating costs- Contractor-friendly installation
F E A T U R E S & B E N E F I T S
- Residential - Commercial - Manufacturing - School & Public - Heathcare
A P P L I C A T I O N S
manufactured by:HUBDS-2010
Rev. 6.15.14
Hebel U Block Nominal Dimensions
Material Properties
Mortar
AAC-2/400
*LEED Credits
*All credits are subject to USGBC interpretation and the appropriate use on the specific building project.
AAC-4/500 AAC-4/600
Physical Data / Footnotes
Ancillary Products Reference
Energy & Atmosphere Materials & Resources Innovations in Design
HBDS-2010 Hebel BlockHLDS-2010 Hebel Lintel BlockHCBDS-2010 Hebel Cored BlockHJBDS-2010 Hebel Jumbo / Mini JumboHM-2010 Hebel MortarHT-2010 Hebel Tools
8”
8”, 10”, 12”
38 44
524437
30
32 3725
195 296
0.25
0.92 1.03
n/a n/a
10
12.5
15 11.65
9.71
7.77
n/a n/a42
4Hr 4Hr4Hr
4Hr 4Hr4Hr
4Hr 4Hr4Hr
4Hr 4Hr4Hr
n/a n/a46
n/a n/a48
n/a n/an/a
Thickness:
Height:
Length:
Compressive Strength (psi)
Dry Bulk Density (pcf)
Design Density (pcf)
Shipping Density (pcf)
Modulus of Elasticity (ksi)
Specific Heat
Thermal Resistance (h ft² °F/Btu)
6”
8”
10”
12”
Sound Transmission Class (db)
6”
8”
10”
12”
UL CertificationsFire Rating: ANSI / UL 263
Design No. U916 (min 8” Block)
Design No. U917 (min 6” Block)
Design No. U919 (min 4” Block)
Design No. U921 (min 6” Block)
Thick Bed Mortar ASTM C270 (base = 3/4” max.)
Thin Bed Mortar ASTM C1660
290 580
0.80
n/a
10.90
13.04
8.70
To order samples or literature, contact customer service at:
Xella ® and Hebel ® are registered trademarks of the Xella Group.
Thermal Conductivity (Btu in/h ft² °F)
Indoor Environment Quality
Product Literature: Data Sheet HUBDS-2010, ASTM C 1386Mortar: Thick-Bed Mortar ASTM C 270 (3/4” max) Thin- Bed Mortar ASTM C 1660Finishes: Plaster, Stucco, Paint w/ perm rating >5 (ASTM C 1692, 9.2)Other Finishes: Tile, Thin Stone/Brick, Spray-on Siding, Acrylic, Drywall (furred out) See Technical Manual and / or Coating Manufacturers recommendations
Footnotes: 1. Hebel Product is not suitable for ground contact applications where water and freezing are possible.
2. Proper dust protection is recommended when cutting Hebel.
EA Prereq 2EA Credit 1
MR Credits1.1, 2, 5
EQ Credit 4.6 ID Credits EA1, MR2, MR5
24”
T
H
L
Toll Free:
T:F:
1-888-SA-XELLA (72-93552)Xella Aircrete North America, Inc.900 Schneider Dr.Cibolo, Texas 78108210/402-3223210/402-6390
hebel-usa@xella.com