Post on 01-Mar-2022
C1
A3
A3
C1
Learning HUB
Existing
Rustic St.
Red
wood
St.
Palmetto St.
1 Story Stucco Bldg.
+ +
+
+
+
Angela Morales Bldg.
Existing
Felix Morales Bldg.
Existing
++
4"
Oak
24" Oak
R.O.W.
Asphalt
Conc.
A/
C on Conc.
8" Pecan
+ ++
+
+
+ Fence
Fence
Fence
Fence
Fence
Fence
++
256 sf
WM
WM
WM
PKL
4-SPV
WM PKL
PKL
WM
4-SPV
Fence
GVCO
+
WM
PKL
SPV
SPVPKL
+
+
+
+
PKLPKL
Grease Trap
+
PKL
SPV
SPV
SPV
Top=35.21
Workforce Building
Existing
WM
4-SPV
WM
4-SPV
CO
FL 8" S 28.95
Rim 34.49
FL 8" NW 30.44
Stm. MH
FL 15" E 27.81
Ramp
SEATING WALL
1’-4"
R32’-
0"
+
R.O.W.R.O.W.
R.O.W.
R.O.W.
R.O.W.R.O.W.
R.O.W.
R.O.W.
R.O.W.
R.O.W.
R.O.W.
R.O.W.
12" Oak
30" Oak
18" Oak
36" Oak
30" Oak
36" Oak 24" Oak
24" Oak
24" Oak
30" Oak
18" Oak
10" Oak
24" Oak
24" Oak
12" Oak
18" Oak
24" Oak
24" Oak
18" Oak
18" Oak
18" Oak
24" Oak
18" Oak
24" Oak
12" Pecan
36" Oak
24" Oak
30" Oak
24" Oak
4" Tree
24" Oak
4" Tree
4" Tree
4" Tree 6" Tree
24" Oak
12" Oak
Fence
Fence
26’-8 1/2"
24’-0"
11’-
4"
28’-2"
8’-
0"
Dumpster
6’x6’
Dumpster
6’x6’
Dumpster
6’x6’
TIME WARNER CABLE
Tim
e
Warner
Cable
Time Warner Cable
Tim
e
Warner
Cable
Time Warner Cable
Time Warner Cable
Tim
e
Warner
Cable
Time Warner Cable
Time Warner Cable
Time Warner Cable
Time Warner Cable
Time Warner Cable
S.W.B.T. PED.
GW
GW
Time Warner Cable
GWS.W.B.T. PED.
PP
PP
PP
GW
GW
Speed Bump
PP
PP
GW
PP GW
PP
H.L.& P. BoxH.L.& P. Box
3-H.L.& P. Box
PP
PPPP
PP
GW PP
PP
PP
PPPP
SBC Buried Cable
SBC Buried CableSBC Buried Cable
SB
C
Buried
Cable
SBC Buried Cable
SBC Telephone Conduit
Phone Mkr.
PPPP
PP
PP
PP
PP
PP GW GWPP
PP
GW
PP PP
PP
PP
FLDLT
FLDLT
FLDLT
PP
EB
GW
PP
PP
GW
SB
C
Buried
Cable
1LEA
1HEA
EDP1
DP2
1LA
1LB
DP1
MS
B
ATS
C
XFMR
45KVA
T1-1
XFMR
15KVA
T1-3
L1A
SE200
SITE PLAN POWERELECTRICAL
MHS
TJB
MHS
2670.00
SCALE: 1"=40’-0"
ELECTRICAL SITE PLAN POWER1
SCALE: 1/4"=1’-0"
FIRST FLOOR ELECTRICAL ROOM2
CONTACTORS
NEW LIGHTINGNEW PANEL SL
1010
2
SE200
4
PP
PP
4
6
7
12
5
3 2
11
13
4
4
4
9
1
8
4
XFMR.
PAD MOUNTED
EXISTING
XFMR.
PAD MOUNTED
EXISTING
16
14
17
18
415
17
1919
POLE #444369 POLE #284344
21
21
20
22
SINGLE AND THREE DUCT DUCTBANKS
SECTIONS ARE SIMILAR
CONDUIT SPACERS
ON 10’ CENTERS
ENCASEMENT
#3 REINFORCING ROD W/ #3 TIES
WHERE SPECIFIED
CONDUIT
O.D.
30"
MINIMUM
CO
ND
UI
T
O.
D.
CO
ND
UI
T
O.
D.
NOT TO SCALE
SECTION
3" 3"*
PVC CONDUIT
* = 7.5"-CONDUIT O.D.
TYPICAL TWO DUCT DUCTBANK
3"
3"
EACH DIRECTION @ 5’-0" O.C.,
CONCRETE
4
CO
ND
UI
T
O.
D.
CO
ND
UI
T
O.
D.
CO
ND
UI
T
O.
D.
30"
MINIMUM
CONDUIT
O.D.
CONDUIT
O.D.RED CONCRETE
ENCASEMENT
CONDUIT SPACERS
ON 10’ CENTERS
FOUR AND EIGHT DUCT DUCTBANK
SECTIONS ARE SIMILAR
#3 REINFORCING ROD W/ #3 TIES
WHERE SPECIFIED
3NOT TO SCALE
SECTION
TYPICAL SIX DUCT DUCTBANK
3" 3"* *
*
PVC CONDUIT
* = 7.5"-CONDUIT O.D.
3"
3"
(TYP)EACH DIRECTION @ 5’-0" O.C.,
AND SANITARY PIPING. REFER TO CIVIL PLANS FOR ADDITIONAL INFORMATION.
22 COORDINATE ROUTING OF NEW ELECTRICAL SECONDARY DUCT BANK WITH THE EXISTING WATER
21 EXISTING SERVICE CONDUITS, FIELD VERIFY EXACT ROUTING.
20 EXISTING MAIN SWITCHBOARD LOCATION.
19 EXISTING OVERHEAD 120V LIGHTING POWER TO BE REMOVED BY CENTERPOINT.
18 EXISTING UNDERGROUND 120V POWER SERVING LIGHT POLE TO REMAIN.
17 EXISTING OVERHEAD PRIMARY TO REMAIN.
FOR POLE LIGHT TO BE RELOCATED BY POWER COMPANY.
16 EXISTING TRANSFORMER POLE WITH LIGHT TO REMAIN TRANSFORMER IS SERVING 120V POWER
WORK FORCE AND LEARNING HUB BUILDINGS TO REMAIN.
15 EXISTING PRIMARY TERMINAL POLES SERVING CENTERPOINT PAD MOUNTED TRANSFORMERS FOR
EXISTING POLE. COORDINATE EXACT REQUIREMENTS WITH TELEPHONE PROVIDER.
ARE BACKFED. PROVIDE IN GROUND SPLICE BOX AND EXTEND (2) 4" EMPTY CONDUITS TO
14 EXISTING PRIMARY POWER AND TELEPHONE SERVICE POLE TO BE REMOVED AFTER SERVICES
MOUNTED CENTERPOINT TRANSFORMER, RE: SE300.
UNDERGROUND FEEDER TO THE FELIX MORALES BUILDING AND BACKFEED FROM THE NEW PAD
13 NEW TRAFFIC RATED PULL BOX, 36"X36" BY DEPTH AS REQUIRED. CAPTURE THE EXISTING
MOUNTED CENTERPOINT TRANSFORMER, RE: SE300.
UNDERGROUND FEEDER TO THE ANGELA MORALES BUILDING AND BACKFEED FROM THE NEW PAD
12 NEW TRAFFIC RATED PULL BOX, 36"X36" BY DEPTH AS REQUIRED. CAPTURE THE EXISTING
INSTALLED.
11 EXISTING BUSSED WEATHER HEADS SERVING BUILDINGS TO BE REMOVED AFTER NEW SERVICE IS
PER CENTERPOINT STANDARDS.
UNDERGROUND, RE: NOTE 9. PROVIDE 2" CONDUIT (SCHEDULE 40, SCHEDULE 80 UNDER DRIVES)
A NEW STEEL POLE PROVIDED BY CENTERPOINT. BACKFEED THIS POLE FROM THE EXISTING POLE
10 COORDINATE WITH CENTERPOINT TO REPLACE THE EXISTING WOODEN POLE STREET LIGHT WITH
9 EXISTING CENTERPOINT POLE STREET LIGHT FED UNDERGROUND TO REMAIN.
ROUTING WITH HCC.
THE OVERHEAD UTILITIES TO UNDERGROUND WITH THE LOW VOLTAGE VENDORS, ALSO COORDINATE
8 INSTALL (4) 4" EMPTY CONDUITS WITH PULLSTRINGS AND COORDINATE THE RELOCATION OF
7 EXISTING CENTERPOINT POLE TO REMAIN.
6 NEW CENTERPOINT PAD MOUNTED SERVICE TRANSFORMER. REFER TO SE300 FOR DETAILS.
ARCHITECT PRIOR TO INSTALLATION.
5 NEW CONCRETE PULL BOX, 36"X36" BY DEPTH AS REQUIRED. STAKE LOCATION FOR REVIEW BY
AND ALL LOW VOLTAGE VENDORS CABLING HAS BEEN RELOCATED.
CENTERPOINT ENERGY AFTER THE PERMANENT UNDERGROUND SERVICE HAS BEEN INSTALLED
4 COORDINATE THE REMOVAL OF THE OVERHEAD SERVICE AND SERVICE POLES WITH
3 NEW UNDERGROUND DUCTBANK PER CENTERPOINT ENERGY STANDARDS.
2 NEW CENTERPOINT TERMINAL POLE.
1 EXISTING CENTERPOINT POWER POLE TO REMAIN.
DRAWING NOTES:
BY HOUSTON COMMUNITY COLLEGE, IN WRITING. LIMIT THE DURATION OF SHUT DOWNS.
OF 30 DAYS PRIOR TO SHUT DOWN. ALL SHUT DOWNS WILL BE DONE AFTER HOURS OR AS APPROVED
C. SCHEDULE ALL SHUT DOWNS WITH HOUSTON COMMUNITY COLLEGE FACILITIES GROUP A MINIMUM
AND HCC PROJECT MANAGER PRIOR TO INSTALLING MANHOLES OR PULLBOXES.
B. ALL MANHOLE AND PULL BOX LOCATIONS SHALL BE STAKED AND REVIEWED BY THE ARCHITECT,
A. RE: SE.000 FOR ADDITIONAL GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
GENERAL NOTES:
1
1
1
1
1
3-26-12 ADD #11
(8 CONDUITS)
3SE200
(8 CONDUITS)
3SE2001
1
(3 CONDUITS)
4SE200
(5 COND)
3SE200
Scale:
Issue:
E&C Project No.:
A/E Project No.:
Drawn By:
Checked By:
CAD File:
Houston Community
College System
Ownership of Instruments of Service:
All reports, plans, specifications, computer files, field data,
notes & other documents and instruments prepared for
Houston Community College System as instruments of
service shall become the property of Houston Community
College System. Houston Community College System
shall gain all common law, statutory and other reserved
rights, including the copyright thereto.
Hccs-Construction Department
3100 Main, 12th Floor
Houston, Texas, 77002
Voice: 713.718.5168
reynaldo.pradia@hccs.edu
Eastside Campus
Houston, TX 77087
6815 Rustic
As Noted
5120 Woodway, Suite 8010
Houston, TX 77056
p: 713.850.1500
f: 713.850.1023
e: info@theldnet.com
As Noted
E&CEngineers & Consultants Inc.
1010 Lamar, Suite 650
Houston, Texas 77002
Tel 713/580-8800
Fax 713/580-8888
www.eceng.com
E&C State of TexasRegistration No. F-003068
3/2
8/2
012
I:\2
650\2
670\m\2
670E site.d
gn
8:5
8:1
8 A
M
3-02-12 Issued for Bid and Construction
C1
A3
A3
C1
Rustic St.
Red
wood
St.
Palmetto St.
1 Story Stucco Bldg.
Bldg.
+
+ +
+
+
+
Angela Morales Bldg.
Existing
Felix Morales Bldg.
Existing
++
4"
Oak
24" Oak
R.O.W.
+
+
+
+
Fence
Fence
Fence
++
256 sf
+
Grease Trap
+
Top=35.21
Workforce Building
Existing
Ramp
SEATING WALLSEATING WALL
+
ELECTRICAL SITE PLAN LIGHTING1 SCALE: 1"=40’-0"
1Ca,c
1Ca,b
2Ca,c
2Cb,c2Ca,b
2Cb,c
2Ca,b
1Ca,c
2Ca,b 2Cb,c
1Cb,c
2Ca,c1Cb,c
2Cb,c
1Ca,b
1Ca,b
1Ca,c
1Cb,c
1Ca,b
3Ca,c
3Ca,b
1Ca,c 1Cb,c
1Ca,b
1Ca,c
1Cb,c
1Ca,c
2Ca,c
2Ca,b
2Ca,b
2Cb,c
1Ca,c
3Ca,b 3Cb,c 3Ca,c1Ca,b 1Cb,c 1Ca,c1Ca,b
2Ca,b
2Ca,c
1Cb,c
TYP
TYP
1Cb,c1Ca,c 1Ca,b 1Cb,c
1Ca,b 3Ca,b
1Cb,c
1Ca,b
1Ca,c
3Cb,c
1Ca,c 1Cb,c 1Ca,c3Ca,b 3Cb,c 3Ca,c
2
2
TYP
1
1
TYP
SE201
PLAN LIGHTINGELECTRICAL SITE
2670.00
4#10,#10G,1"C 5#10,#10G,1"C
6#10,#10G,1"C6#10,#10G,1"C
1"C
2#10,#10G,
1"C
4#10,#10G,
1"C
5#10,#10G,
1"C
6#10,#10G,
1"C
6#10,#10G,
5#10,#10G,1"C 5#10,#10G,1"C
6#10,#10G,1"C
6#10,#10G,1"C8#10,#10G,1"C
1"C
9#10,#10G,
9#10,#10G,1"C
9#10,#10G,1"C
9#10,#10G,1"C
2
SE200
1"C
9#10,#10G,
1"C
3#10,#10G,
1"C
3#10,#10G,
1"C
2#10,#10G,
1"C
6#10,#10G,
1"C
4#10,#10G, 1"C
2#10,#10G,
1"C
2#10,#10G,
1"C
4#10,#10G,
1"C
5#10,#10G,
1"C
6#10,#10G,
1"C
6#10,#10G,
MHS
TJB
MHS
1"C
2#10,#10G,
1"C
9#10,#10G,
1"C
6#10,#10G,
2Ca,b
6#10,#10G,1"C
6#10,#10G,1"C
2Cb,c
1"C
4#10,#10G,
2Ca,c
1"C
5#10,#10G,
2Ca,b
2Cb,c
2Ca,c
SCHEDULE FIXTURELIGHT
PLANS LIGHTING SITE WITH TYPES COORDINATE PROJECT THE ON USED NECESSARILY NOT ARE SHOWN FIXTURES LIGHTALL
TYPE DESCRIPTIONLuminaire
Watts/
A1
MOUNTING. ARM ARCHITECTURAL 49/80180-C), #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITEDISTRIBUTION,
CUT-OFF FULL IES SYMMETRICAL LENS, GLASS FLAT TEMPERED BALLAST, LOSS LOW SAVING ENERGY PHASE, SINGLE 480V, LAMP, HALIDEMETAL
START PULSE 400W VERTICAL (1) MOUNTING. LINK SITE FOR SUITABLE ARM ARCHITECTURAL INTEGRAL WITH LIGHT AREA PARKINGMOONGOOSE FIXTURE:
509STL23000D5P0-SPCL-HCCA+STL2POLEKITD5P0+AB-27-4+TMP40000A
SITELINK ARM+(4)TNUT3/8-10TPD5+(1)EC-1197+(1) ARCHITECTURAL WITH MONGOOSE G40LPM48LSFAA-SL-HCCA HOLOPHANE (1)MANUFACTURER:
SET. BOLT ANCHOR WITH 49/80180-C), #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITE SCREWS, TAMPER-RESISTANTSTEEL
STAINLESS WITH HOLE HAND COVERS, NUT WITH BASE AND TOP POLE ALLOY ALUMINUM SHAFT, ALUMINUM EXTRUDED HIGH, 30’ POLE, DUTY MEDIUMPOLE:
MS400/PS/BU-ONLY/BT28 - LAMP 64189 SYLVANIA(1)LAMP:
A2
MOUNTING. ARM ARCHITECTURAL 49/80180-C), #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITEDISTRIBUTION,
CUT-OFF FULL IES SYMMETRICAL LENS, GLASS FLAT TEMPERED BALLAST, LOSS LOW SAVING ENERGY PHASE, SINGLE 480V, LAMP, HALIDEMETAL
START PULSE 400W VERTICAL (2) MOUNTING. LINK SITE FOR SUITABLE ARM ARCHITECTURAL INTEGRAL WITH LIGHT AREA PARKINGMOONGOOSE FIXTURE:
1018STL23000D5P0-SPCL-HCCA+STL2POLEKITD5P0+AB-27-4+TMP40000A
SITELINK ARM+(4)TNUT3/8-10TPD5+(2)EC-1197+(1) ARCHITECTURAL WITH MONGOOSE G40LPM48LSFAA-SL-HCCA HOLOPHANE (2)MANUFACTURER:
SET. BOLT ANCHOR WITH 49/80180-C), #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITE SCREWS, TAMPER-RESISTANTSTEEL
STAINLESS WITH HOLE HAND COVERS, NUT WITH BASE AND TOP POLE ALLOY ALUMINUM SHAFT, ALUMINUM EXTRUDED HIGH, 30’ POLE, DUTY MEDIUMPOLE:
MS400/PS/BU-ONLY/BT28 - LAMP 64189 SYLVANIA(2)LAMP:
A3
MOUNTING. ARM ARCHITECTURAL 49/80180-C), #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITEDISTRIBUTION,
CUT-OFF FULL IES SYMMETRICAL LENS, GLASS FLAT TEMPERED BALLAST, LOSS LOW SAVING ENERGY PHASE, SINGLE 480V, LAMP, HALIDEMETAL
START PULSE 400W VERTICAL (3) MOUNTING. LINK SITE FOR SUITABLE ARM ARCHITECTURAL INTEGRAL WITH LIGHT AREA PARKINGMOONGOOSE FIXTURE:
1527STL23000D5P0-SPCL-HCCA+STL2POLEKITD5P0+AB-27-4+TMP40000A
SITELINK ARM+(4)TNUT3/8-10TPD5+(3)EC-1197+(1) ARCHITECTURAL WITH MONGOOSE G40LPM48LSFAA-SL-HCCA HOLOPHANE (3)MANUFACTURER:
SET. BOLT ANCHOR WITH 49/80180-C), #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITE SCREWS, TAMPER-RESISTANTSTEEL
STAINLESS WITH HOLE HAND COVERS, NUT WITH BASE AND TOP POLE ALLOY ALUMINUM SHAFT, ALUMINUM EXTRUDED HIGH, 30’ POLE, DUTY MEDIUMPOLE:
MS400/PS/BU-ONLY/BT28 - LAMP 64189 SYLVANIA(3)LAMP:
C1
PHASE. 1 480V, 49/80180-C), #P5 METALLIC DRYLAC (TIGER COATPOWDER
GRAPHITE DISTRIBUTION, CUT-OFF FULL IES SYMETRICAL REFRACTOR, BOWL GLASS PRISMATIC FIXTURE, WALKWAY MOUNTED POLE HALIDEMETAL
START PULSE WATT 175 VERTICAL MOUNTING, SITELINK FOR SUITABLE ARM, PENDANT CROOK BISHOP’S WITH FIXTURE PEDESTRIAN HALLBROOK FIXTURE:
240 COVER. BOLT WITH 49/80180-C) #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITE SCREWS. RESISTANT TAMPER SSWITH
HOLE HAND BASE. STYLE SALEM 13" AND TOP POLE ALLOY 356 CAST SHAFT. SQUARE 4.5" ALUMINUM HIGH,EXTRUDED 16’-0" POLE, TRACK FLUTEDPOLE:
SL4S131600D5PO-SPCL-HCCC+AB-31-4+TMP400006
SLHLB01F4D5+(2)TNUT3/8-10SL4/5D5+(1)SLGAGMKIT-SPCL+(1)SITELINK HALLBROOK+(1)SITELINK GS175PM482AS75N HOLOPHANE (1):MANUFACTURER
MVR175/VBU/PA LAMP 12622 GE(1)LAMP:
PHASE. 1 480V, 49/80180-C), #P5 METALLIC DRYLAC (TIGER COAT POWDER GRAPHITE DISTRIBUTION, CUT-OFFFULL
IES SYMETRICAL LENS, GLASS SAG PRISMATIC LAMP, LIGHT,VERTICAL POLE METROVUE MOUNTED YOLK HALIDE METAL START PULSE WATT W175FIXTURE:
240 COVER. BOLT WITH 49/80180-C) #P5 METALLIC DRYLAC(TIGER
COAT POWDER GRAPHITE SCREWS. RESISTANT TAMPER SS WITH HOLE HAND BASE. STYLE SALEM 13" AND TOP POLE ALLOY 356 CAST FACTOR. GUST1.3
TIME LOAD WIND MPH 90 SHAFT, ALLOY ALUMINUM FLUTED 4.5" 6061-T6, EXTRUDED WITH HIGH 14’-0" TRACKS, MOUNTING 4 POLE, LOCK TRACK FLUTEDPOLE:
SL4S131400D5P3-AB-31-4. (1)EYP-175PM-48-H-6-A-N+(1)SITELINK YOKE METROVUE PEDESTRIAN HOLOPHANE SINGLE:MANUFACTURER
MVR175/VBU/PA GE(1)LAMP:
Panel SL -Project EASTSIDE COLLEGESOUTHEAST
-Location ROOMELECTRICAL No.E&C 2670
InformationPanel LoadsPanel APhase BPhase CPhase Total
Voltage 4W 3P,277/480V, VA LightingPanel 7190 6730 6517 20437
TypePanel Panelboard VA ReceptaclePanel 0 0 0 0
AmpsBus Neutral 100%100A, VA EquipmentPanel 0 0 0 0
TypeBus Copper/65,000AIC VAFTL 0 0 0 0
MainsPanel MLO100A VA ConnectedTotal 7190 6730 6517 20437
MtgBreaker Bolt-In Amps ConnectedTotal 26 24 24 25
Enclosure Surface 1NEMA VANEC 8988 8413 8146 25546
Accessories BusGround AmpsNEC 32 30 29 31
Ckt. Bkr. UseCircuit Load Type Ph. Ckt. Bkr. UseCircuit Load Type
1 - -- 4021 2 A 2 - -- 639 2
3 30/3 (Security) 1C Contactor LtgSite 3791 2 B 4 30/3 3C Contactor LtgSite 639 2
5 - -- 3808 2 C 6 - -- 639 2
7 - -- 2530 2 A 8 Space
9 30/3 2C Contactor LtgSite 2300 2 B 10 Space
11 - -- 2070 2 C 12 Space
13 Space 2 A 14 Space
15 Space 2 B 16 Space
17 Space 2 C 18 Space
19 Space A 20 Space
21 Space B 22 Space
23 Space C 24 Space
25 Space A 26 Space
27 Space B 28 Space
29 Space C 30 Space
NEC) (per Equip. Kitchen = 6 (125%), Motor Lgst. = 5 (100%), Heating = 4 (100%), A/C = 3 (125%), Lighting = 2 (100%), Equip. = 1 NEC), (per Recepts = 0 Types:Load
Notes:
L1
4
4
3
3 3
3
4 BORE CONDUIT UNDER THE EXISTING SIDEWALK.
3 STUB CONDUIT UP POLE FOR FUTURE COMMUNICATIONS, REFER TO POLE BASE DETAIL, 1/SE300.
INFORMATION.
2 INDICATES CONTACTOR NUMBER, SMALL LETTERS INDICATE PHASE, RE: 2/SE300 FOR ADDITIONAL
TRAFFIC RATED COVER WHEN INSTALLED IN TRAFFIC AND PARKING AREAS.
MAKE ALL CONNECTIONS WATERTIGHT. PROVIDE STEEL COVER WITH ELECTRICAL ON COVER, PROVIDE
1 PROVIDE IN-GROUND PRECAST CONCRETE PULL BOX MANUFACTURED BY BROOKS. 24"X24"BY 12"DEEP.
DRAWING NOTES:
B. SCHEDULE ALL WORK ON THE SITE WITH HOUSTON COMMUNITY COLLEGE PRIOR TO SCHEDULING.
A. REFER TO SE000 FOR ADDITIONAL GENERAL NOTES AND SYMBOLS AND ABBREVIATIONS.
GENERAL NOTES:
3
3 3
1
1
1 3-26-12 ADD #1
A3 A3 A3 A3A3A2
A3A3
A1
A1
C1 C1C1
L1
L1 L1 L1 L1 L1 L1
C1
C1
A1
C1 C1C1C1C1 C1
C1C1
A2
A2
L1
L1
L1
L1
C1
A2
A2
A3
Scale:
Issue:
E&C Project No.:
A/E Project No.:
Drawn By:
Checked By:
CAD File:
Houston Community
College System
Ownership of Instruments of Service:
All reports, plans, specifications, computer files, field data,
notes & other documents and instruments prepared for
Houston Community College System as instruments of
service shall become the property of Houston Community
College System. Houston Community College System
shall gain all common law, statutory and other reserved
rights, including the copyright thereto.
Hccs-Construction Department
3100 Main, 12th Floor
Houston, Texas, 77002
Voice: 713.718.5168
reynaldo.pradia@hccs.edu
Eastside Campus
Houston, TX 77087
6815 Rustic
As Noted
5120 Woodway, Suite 8010
Houston, TX 77056
p: 713.850.1500
f: 713.850.1023
e: info@theldnet.com
As Noted
E&CEngineers & Consultants Inc.
1010 Lamar, Suite 650
Houston, Texas 77002
Tel 713/580-8800
Fax 713/580-8888
www.eceng.com
E&C State of TexasRegistration No. F-003068
3/2
6/2
012
I:\2
650\2
670\m\2
670E
L.d
gn
9:5
7:3
9 A
M
3-02-12 Issued for Bid and Construction
1600A
TVSS
MSB
3 SPACES125A300A225A90A100A100A
1600A, 480Y/277V, 3PH, 4W, 1/2 NEUTRAL 100,000 A.I.C. SYM.
2"C
3#4/0, #4 GND,
1 1/4"C
4#3, #8 GND,
300A 150A1000A
1 1/4"C
4#3, #8 GND, 3#4, #8 GND, 1"C
#4 GND, 2"C
3-250KCMIL,
#4 GND, 2"C
3-250KCMIL,
1 1/2"C
3#2/0, #6 GND,
1 1/2"C
3#1/0, #6 GND,
1 2 3 4 5 6
EXISTING SWITCHBOARD - MDP 1200A, 480/277, 3PH, 41 & GND 100,000 AIC RMS SYM
SPARESPARE
BUS
GROUND
60
0/
3
60
0/
3
22
5/
3
12
5/
3
60
0/
3
TVSS
SPARESPARE
MHS
TJB
MHS
2670.00
M
NOT TO SCALE
ELECTRICAL ONE LINE DIAGRAM3
SL
PNL
NEW
TERMINAL POLE
NEW CENTERPOINT
1C 2C 3C
CONTROL PANEL
NEW LIGHTING
REFER TO 2/E200
MOUNT ABOVE THE PANEL
LIGHTING CONTACTORS
WITH PILOT LIGHT
C
O
M
M
O
N
O
F
F
L
I
G
H
T
O
N
WIRING
CLASS 2 LOW VOLTAGE
WIRING
CLASS 2 LOW VOLTAGE
C
AUX
COPEN
CLOSE
OFF
ON
C
AUX
COPEN
CLOSE
OFF
ON
SITE LIGHTING
SITE LIGHTING
LIGHTING BRANCH CIRCUIT
LIGHTING BRANCH CIRCUIT
PILOT LIGHTS
ON/OFF
PILOT LIGHTS
ON/OFF
1C
2C
LIGHTING CONTROL PANEL. (TYPICAL)
AUXILIARY CONTACT FOR MONITORING BY
MOMENTARY ON/OFF PUSHBUTTONS AND
CONTACTORS WITH 277 VOLT COIL,
30AMP/3P/480V, MECHANICALLY-HELD LIGHTING
GROUND
NEUTRAL
277V
MOMENTARY SWITCH
DOUBLE THROW CENTER OFF
LOW VOLTAGE SINGLE POLE
2#14
S
T
U
P
N
I
S
T
U
P
T
U
OR
R
R
R
REQUIRED.
SUPPLY SIZE AS
AND POWER
TRANSFORMER
120V TO 24VAC
PAIR PLENUM RATED
SHIELD TWISTED
RS 485
BOARD ANDOVER PSR-1-T
PHOTO CELL TRANSMITTER
RATED
4#18 PLENUM
RATED
2#18AWG PLENUM
CONTROLLER
EXISTING
NEAREST
#14
NOT TO SCALE 2LIGHTING CONTROL WIRING DIAGRAM
CONTROL OF CONTACTORS)
(QUANTITY AS REQUIRED FOR
INTERFACE RELAY 1DEC RR SERIES
THE OUTPUT
WITH FUSES ON
SIZE AS REQUIRED
TRANSFORMER
CONTROL POWER
277V TO 120VAC
ACCESSIBLE CEILINGS. PROVIDE CONDUIT WHERE EXPOSED.
2. PLENUM RATED WIRING MAY BE USED FOR LOW VOLTAGE WIRING ABOVE
TO ADD NEW POINTS INDICATING RELAYS CONTROLLING LIGHTING LEVELS.
PROGRAM LIGHTING SCHEDULES AND UPDATE EXISTING GRAPHIC PACKAGE
(832)-724-8168). CONTROLS CONTRACTOR SHALL PROVIDE ALL COMPONENTS,
CONTROLS CONTRACTOR, KRATOS SOUTHEAST LP (CONTACT ROBERT OLDROYD
1. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR HIRING THE BUILDING
NOTES:
ANALOG PHOTOCELL ANDOVER PSR-1
CONTROL PANEL
FEEDBACK TO LIGHTING
DETAILSDIAGRAM AND ELECTRICAL RISER
SE300
20/1 BREAKER
3#12 TO EXISTING
L1A-42
RATED
100,000AIC
100A/3P
NEW
4#3,#8G,1-1/4"C
FOR CONTROL OF THE LIGHTING CONTACTORS)
(QUANTITY OF CONTROLLERS AS REQUIRED
WITH 8 INPUT/ OUTPUT POINTS
CONTINUM INFINET 11 2810 CONTROLLER
NEMA 1 ENCLOSURE WITH (2) ANDOVER
20/1 BREAKER
EXISTING
E#12 TO
L1A-42
WIRING TYPICAL TO THE ABOVE SHOWN FOR CONTACTORS 1C & 2C.
PROVIDE ADDITIONAL 30AMP CONTACTORS AS SHOWN ON THE PLANS
65,000ASC
TRANSFORMER
CENTERPOINT
NEW PAD MOUNTED
CENTERPOINT
METER BY
EXISTING SWITCHBOARD
PULL NEW FEEDER TO THE
ANGELA MORALES BUILDING
SECONDARY FEEDER TO
EXISTING UNDERGROUND
INSTALL SPLIT PULLBOX OVER
REMOVE FEEDER.
WITH 4-300MCM,
(6) EXISTING 3"C EACH
SWITCHBOARD)
(100,000AIC RATED
BUILDING
TO ANGELA MORALES SWITCHBOARD)
(100,000AIC RATED
BUILDING
TO FELIX MORALES
WITH 4#500MCM
(3) 4"C EACH
WITH 4#400MCM
(5) 3"C EACH
RE: SE400
POWER COMPANY STANDARDS,
2-6"PVC UP POLE PER
4ELECTRICAL PARTIAL ONE LINE DIAGRAM (ANGELA BLDG.)NOT TO SCALE
SERVICE
AND COLD WATER
BUILDING STEEL
#3/0 TO GND ROD
EXTEND
5ELECTRICAL PARTIAL ONE LINE DIAGRAM (FELIX BLDG.)NOT TO SCALE
AND CENTERPOINT.
TO BE DOWN ON WEEKENDS, COORDINATE WITH HCC
ALL SHUT DOWN REQUIRED TO INSTALL NEW FEEDERS
NOTE:
TO REMAIN
EXISTING 4/0
CODE BLUE STATIONS
FOR FUTURE
PROVIDE INPUT
Analysis LoadPreliminary
Ave Rustic 6815 Campus SoutheastHCC
kVA Amps
CenterPoint from Demand PeakExisting 652kVA 652 785
Demand NEC+25% 163 196
Lighting SiteNew 20 25
Duty Continuous+25% 5 6
Total kVA841 A1011
ANCHOR BOLTS FURNISHED
WITH LIGHTING POLE.
RE: APPROVED LIGHT
FIXTURE SUBMITTAL FOR
BOLT PATTERN
ROUND POURED
CONCRETE BASE
NOT TO SCALE
LIGHTING POLE
FINISHED GRADE
POLE BASE COVER
BASE DETAIL
3|4"CHAMFERED CORNER
UPPER AND LOWER
LEVELING NUTS
TYPICAL SITE LIGHTING POLE
HAND HOLE
FOR EACH FIXTURE AT
FUSES IN THE POLE BASE
PROVIDE DUAL IN-LINE
36" AFG IN PARKING AREAS (NOT WITHIN ISLAND)
30" AFG IN PARKING AREA (WITHIN ISLAND)
24" MIN BELOW GRADE
CONDUIT FOR LIGHTING POWER
4" AFG IN LANDSCAPE AND GRASS AREAS
INFORMATION
DETAILS FOR ADDITIONAL
REFER TO STRUCTURAL
REINFORCING:
RE: STRUCTURAL DETAIL
1
WIRE TO GROUND ROD
CADWELD GROUND
FROM POLE GROUND WG
#8 COPPER WIRE
3/4" X 10’ GROUND ROD
BUSHING (TYP)
PROVIDE 1" DIAMETER
GREATER THAN POLE
BASE BOLT CIRCLE.
J-BOLT ANCHORS SECURELY
VERTICAL REINFORCING BARS
TIED OR WELDED TO
24" MIN BELOW GRADE
WHERE SHOWN ON THE PLANS
2 - 1" EMPTY CONDUIT FOR COMM
PAD MOUNTED TRANSFORMER
4-#400kCMIL TO NEW CNP
EXTEND 5-3" CONDUITS WITH
PAD MOUNTED TRANSFORMER
4-#500kCMIL TO NEW CNP
EXTEND 3-4" CONDUITS WITH
1-3"CONDUIT
kCMIL AND SPARE
AND PULL IN 4-400
REUSE 5-CONDUITS
CONDUITS.
6-3"EXISTING
W/4-500MCM
3-EXISTING 4"C EA
NEW FEEDER
REPULL
WITH 4-500MCM,
(3) EXISTING 4"C EACH
FOR SPLICE AND SEAL WATER TIGHT.
COMPRESSION BARREL CONNECTORS
THE EXISTING CONDUITS. USE INLINE
TO THE EXISTING SWITCHBOARD VIA
TO THE EXISTING FEEDER
SPLICE THE NEW FEEDER
FELIX MORALES BUILDING
SECONDARY FEEDER TO
EXISTING UNDERGROUND
INSTALL SPLIT PULLBOX OVER
1
ADD #13-26-12 1
Scale:
Issue:
E&C Project No.:
A/E Project No.:
Drawn By:
Checked By:
CAD File:
Houston Community
College System
Ownership of Instruments of Service:
All reports, plans, specifications, computer files, field data,
notes & other documents and instruments prepared for
Houston Community College System as instruments of
service shall become the property of Houston Community
College System. Houston Community College System
shall gain all common law, statutory and other reserved
rights, including the copyright thereto.
Hccs-Construction Department
3100 Main, 12th Floor
Houston, Texas, 77002
Voice: 713.718.5168
reynaldo.pradia@hccs.edu
Eastside Campus
Houston, TX 77087
6815 Rustic
As Noted
5120 Woodway, Suite 8010
Houston, TX 77056
p: 713.850.1500
f: 713.850.1023
e: info@theldnet.com
As Noted
E&CEngineers & Consultants Inc.
1010 Lamar, Suite 650
Houston, Texas 77002
Tel 713/580-8800
Fax 713/580-8888
www.eceng.com
E&C State of TexasRegistration No. F-003068
3/2
6/2
012
I:\2
650\2
670\m\2
670erisr.dgn
9:5
8:1
0 A
M
3-02-12 Issued for Bid and Construction