CITY OF HOUSTON - C-AIR-S Mechanical INC. · for the city of houston ... ffa fire alarm fc fire...
Transcript of CITY OF HOUSTON - C-AIR-S Mechanical INC. · for the city of houston ... ffa fire alarm fc fire...
10
SUBMITTAL
NOVEMBER 30, 2015
PROJECT LOCATION
PROJECT LOCATION
N
N
VICINITY MAP
LOCATION MAP
CONTRACTING AUTHORITY
FOR THE CITY OF HOUSTON
GENERAL SERVICES DEPARTMENT
SCOTT MINNIX DIRECTOR
ADMINISTRATION & REGULATORY AFFAIRS
ALFRED J. MORAN Jr., DIRECTOR
DISTRICT COUNCIL MEMBERS COUNCIL MEMBERS AT-LARGE
JOLANDA "JO" JONES
POSITION 5
SUE LOVELL
POSITION 2
C.O. "BRAD" BRADFORD
POSITION 4
STEPHEN COSTELLO
POSITION 1
MELISSA NORIEGA
POSITION 3
ANNE CLUTTERBUCK
DISTRICT C
AL HOANG
DISTRICT F
JAMES G. RODRIGUEZ
DISTRICT I
JARVIS JOHNSON
DISTRICT B
MIKE SULLIVAN
DISTRICT E
EDWARD GONZALEZ
DISTRICT H
BRENDA STARDIG
DISTRICT A
WANDA ADAMS
DISTRICT D
OLIVER PENNINGTON
DISTRICT G
MAYOR
ANNISE D. PARKER
CONTROLLER
RONALD C. GREEN
CITY OF HOUSTON
GENERAL SERVICES DEPARTMENT
TEAGUE ADMINISTRATION BUILDING INTERIOR RENOVATIONS DESIGN
5900 TEAGUE, HOUSTON, TEXAS
WBS NO.: S-000020-0007-3-01-02
610
610
610
610
288
I-45
I-10
I-10
SAM HOUSTON PKWY
SAM HOUSTON PKWY
SA
M H
OU
ST
ON
P
KW
Y
S
A
M
H
O
U
S
T
O
N
P
K
W
Y
5
9
5
9
I
-
4
5
PROGRAM / PROJECT MANAGER
GENERAL SERVICES DEPARTMENT
100% CD REVIEW
PROZIGN701 Shepherd, Suite 200 | Houston, TX 77007P ( 7 1 3 ) 9 7 7 - 6 0 6 0 | F ( 7 1 3 ) 9 7 7 - 6 0 8 6
A R C H I T E C T S2
9
0
SA
M H
OU
ST
ON
P
KW
Y
2
9
0
Username:
ALEX MARTINEZ
Date/Time:
11/15/2015 3:19 PM
Filename:
P:\41136\[projects]\1449.15 Teague Admin. Bldg Interior Inprovements\Drawings\CDs\A00.dwg
@ AT& AND/ PER℄ CENTER LINE∠ ANGLEØ ROUND / DIAMETER
CHANNELPLATESQUARE FOOT (FEET)
A ACOUS ACOUSTICALAJUST ADJUSTABLEADJ ADJACENTAD ACCESS DOORAFF ABOVE FINISH FLOORAGG AGGREGATEAHU AIR HANDLING UNITALT ALTERNATEALUM ALUMINUMANOD ANODIZEDAPPROX APPROXIMATELYAP ACCESS PANELARCH ARCHITECT/ARCHITECTURALASPH ASPHALTATN ATTENUATION/ATTENUATINGAUTO AUTOMATICAUX AUXILIARYAVE AVENUEAVG AVERAGEA/C AIR CONDITIONINGA/V AUDIO VISUAL
B BD BOARDBLDG BUILDINGBLKG BLOCKINGBLK BLOCKBM BEAMBOT BOTTOMBRG BEARINGBRKT BRACKETBSMT BASEMENTBTW BETWEENBUR BUILT UP ROOFINGB&B BALLED & BURLAPPEDB-B BACK TO BACKB.M. BENCH MARKB/F BOTH FACES
C CAB CABINETCB CATCH BASINCCTV CLOSED CIRCUIT TELEVISIONCEM CEMENTCER CERAMICCFMF COLD FORMED METAL
FRAMINGCIP CAST IN PLACECI PIPE CAST IRON PIPECJ CONTROL JOINTCKBD CHALKBOARDCLG CEILINGCLR CLEAR/CLEARANCECL CLOSETCMU CONCRETE MASONRY UNITCNTR COUNTERCOL COLUMNCOMPRES COMPRESSIBLECOMP COMPOSITIONCONC CONCRETECOND CONDITIONCONF CONFERENCECONST CONSTRUCTIONCONTR CONTRACTORCONT CONTINUOUSCORRU CORRUGATEDCORR CORRIDORCG CORNER GUARDCSMT CASEMENTCTR CENTERCTSK COUNTERSUNKCT CERAMIC TILECU FT CUBIC FOOT (FEET)CU YD CUBIC YARDC CURBC-C CENTER TO CENTERC.O. CASED OPENING
D DBL DOUBLEDEFL DEFLECTIONDF DRINKING FOUNTAINDIAG DIAGONALDIA DIAMETERDIM DIMENSIONDISC DISCONNECTDISP DISPENSERDL DEAD LOADDMPFG DAMPPROOFINGDN DOWNDOOR DOORDS DOWNSPOUTDTL DETAILDWC DRYWALL FURRING
CHANNELDWG DRAWINGD DEPTH
E EA EACHEFOB EXTERIOR FACE OF BUILDINGEJ EXPANSION JOINTELAS ELASTIC (ELASTOMERIC)ELEC ELECTRICALELEV ELEVATOREL ELEVATIONEM EMERGENCYEP EXPLOSION PROOFEQUIP EQUIPMENTEQ EQUALESR ELASTIC SHEET ROOFINGEWC ELECTRONIC WATER
COOLEREWH ELECTRIC WATER HEATEREW EACH WAYEXH EXHAUSTEXIST EXISTINGEXPAN EXPANSIONEXP EXPOSEDEXT EXTERIOR
F FA FIRE ALARMFC FIRE CODEFD FLOOR DRAINFEC FIRE EXTINGUISHER CABINETFHC FIRE HOSE CABINETFH FIRE HYDRANTFIN FINISH/FINISHEDFIXT FIXTUREFLRG FLOORINGFLR FLOORFLSHG FLASHINGFLUOR FLUORESCENTFPW FLOOD PROTECTION WALLFL FLOW LINEFM FACTORY MUTUAL
FRPF FIREPROOFFRTW FIRE RESISTANT TREATED
WOODFSEC FOOD SERVICE EQUIPMENT
CONTRACTORFS FULL SIZEFTG FOOTINGFT FOOT (FEET)FURN FURNISHFURR FURRED/FURRINGFV FIELD VERIFYFVC FIRE VALVE CABINET
G GALV GALVANIZEDGAL GALLONGA GAGEGC GENERAL CONTRACTORGD GUARDGEN GENERALGI GALVANIZED IRONGL GLASS, GLAZINGGMP GUARANTEED MAXIMUM
PRICEGR GRADE, GRADINGGYP GYPSUM, GYP BD,GWB GYPSUM WALLBOARD
H HB HOSE BIBBHC HOLLOW COREHDCP HANDICAPPEDHDWD HARDWOODHDWR HARDWAREHD HEADHFS HALF FULL SIZEHM HOLLOW METALHORIZ HORIZONTALHP HORSE POWERHR HOURHT HEIGHTHVAC HEATING/VENTILATION AIR
CONDITIONINGHYD HYDRANT
I ID INSIDE DIAMETERINCAND INCANDESCENTINCL INCLUDEINFO INFORMATIONINSUL INSULATION/INSULATINGINT INTERIORIN INCHIPS INSIDE PIPE SIZE
J JAN JANITORJST JOISTJT JOINT
L LAM LAMINATELAV LAVATORYLGTH LENGTHLH LEFT HANDLV LEVELLIN LINEARLL LIVE LOADLT LIGHTLWT LIGHTWEIGHT
M MACH MACHINEMAINT MAINTENANCEMAS MASONRYMATL MATERIALMAX MAXIMUMMECH MECHANICALMEMB MEMBRANEMEP MECHANICAL, ELECTRICAL,
PLUMBINGMFR MANUFACTURERMH MANHOLEMIN MINIMUMMISC MISCELLANEOUSML METAL LATHMO MASONRY OPENINGMR MOISTURE RESISTANTMTD MOUNTEDMTG MOUNTINGMTL METALMULL MULLION
N NIC NOT IN CONTRACTNOM NOMINALNO.or # NUMBERNRC NOISE REDUCTION
COEFFICIENTNTS NOT TO SCALE
O OA OVERALLOC ON CENTER(S)OD OUTSIDE DIAMETEROFCI OWNER FURNISHED /
CONTRACTOR INSTALLEDOFF OFFICEOFOI OWNER FURNISHED /
OWNER INSTALLEDOH OVERHEADOP OPERABLE PARTITIONOPH, OPP HD OPPOSITE HANDOPNG OPENINGOPP OPPOSITEORD OVERFLOW ROOF DRAINO/A OUTSIDE AIR
P PART PARTITIONPCF POUNDS PER CUBIC FOOTPCP PORTLAND CEMENT PLASTERPCT PORCELIAN CERMIC TILEPERF PERFORATEDPLAST PLASTERPLAS PLASTICPLBG PLUMBINGPLWD PLYWOODPNL PANELPOL POLISHEDPRKG PARKINGPR PAIRPSF POUNDS PER SQUARE FOOTPSI POUNDS PER SQUARE INCHPTD PAINTEDPVC POLYVINYL CHLORIDEPVG PAVINGPVMT PAVEMENT PROPERTY LINEP/C PRECASTPFP PREFINISHED PANEL
Q QT QUARRY TILE
R RCP REINFORCED CONCRETEPIPERD ROOF DRAINREBAR REINFORCING BARRECEPT RECEPTIONRECOM RECOMMENDATIONREC RECESSEDREF:, RE: REFER TO (DRAWING)REG REGULATIONREINF REINFORCED
REQD REQUIREDRES RESILIENTRET RETURNREV REVISIONRE REFER TORFG ROOFINGRH RIGHT HANDR RISERRM ROOMROW RIGHT OF WAYRAD RADIUSR/AG RETURN AIR GRILLER/A RETURN AIR
S SCHED SCHEDULESC SOLID CORESECT SECTIONSF SQUARE FEETSHLV SHELVES/SHELVINGSHTHG SHEATHINGSHT SHEETSIM SIMILARSPEC SPECIFICATIONSQ SQUARESSTL STAINLESS STEELSSR STANDING SEAM METAL
ROOFSTAB STABILIZE(D)STA STATIONSTC SOUND TRANSMISSION
COEFFICIENTSTD STANDARDSTL STEELSTOR STORAGESTRUCT STRUCTURE/STRUCTURALSUSP SUSPENDEDSW SWITCHSYN SYNTHETICS/AD SUPPLY AIR DIFFUSER
T TCOC TEXTURE COATINGTC TOP OF CURBTEL TELEPHONETEMP TEMPEREDTHK THICK(NESS)THRES THRESHOLDTKBD TACKBOARDTOS TOP OF STEELTOSS TOP OF STRUCTURAL STEELTRANS TRANSFORMERTRZO TERRAZZOT TREADTTC TELEPHONE TERMINAL
CABINETTV TELEVISIONTYP TYPICAL
U UL UNDERWRITERSLABORATORY
UNO UNLESS NOTED OTHERWISEUR URINAL
V VAC VACUUMVCT VINYL COMPOSITION TILEVERT VERTICALVEST VESTIBULEVIF VERIFY IN FIELDVWC VINYL WALLCOVERING
W WC WATER CLOSETWDW WINDOWWD WOODWF WIDE FLANGEWH WALL HUNGWI WROUGHT IRONWP WATERPROOF/
WATERPROOFINGWR WATER RESISTANTWT WEIGHTWWF WELDED WIRE FABRIC
WORK POINTW/I WITHINW/O WITHOUTW/ WITH
X XFMR TRANSFORMER
ABBREVIATIONS GENERAL NOTES1. UNDERGROUND UTILITIES TIE-IN LOCATIONS ACCORDING TO COUNTY'S RECORD
DRAWINGS. ANY DEVIATION FROM THESE RECORDS SHALL BE VERIFIED ANDLOCATED BY THE GENERAL CONTRACTOR.
2. THESE CONSTRUCTION DOCUMENTS ARE THE DIAGRAMMATIC EXPRESSION OF THEARCHITECT'S DESIGN INTENTIONS. CONTRACTORS SHALL NEVER SCALE THEDOCUMENTS FOR MEASUREMENTS.
3. CONTRACTORS SHALL ABIDE BY ALL APPLICABLE FEDERAL, STATE AND LOCAL CODESAND ORDINANCES, AND REFER ANY CONFLICTING REQUIREMENTS OF REFERENCEDCODES, STANDARDS AND PRACTICES OR INTERPRETATION OF SUCH REQUIREMENTSTO THE ARCHITECT FOR DECISION BEFORE PROCEEDING WITH THE WORK.
4. CONTRACTOR SHALL NOTIFY THE ARCHITECT ANY OF DISCREPANCIES BETWEENDRAWINGS, SPECIFICATIONS AND SITE CONDITIONS IMMEDIATELY.
5. ALL SUBCONTRACTORS SHALL DO THEIR BEST TO PROFESSIONALLY COORDINATE THEIRWORK WITH EACH OTHER, NOTIFY THE GENERAL CONTRACTOR OF ANYDISCREPANCIES AND DIFFICULTIES.
6. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS AND SHALLOBTAIN THE ARCHITECT'S APPROVAL FOR ANY CHANGES.
7. ALL OTHER WORK REQUIRED BUT NOT SPECIFIED IN THESE DOCUMENTS, SHALL BEPERFORMED BY CONTRACTORS TO MEET THE GENERAL PRACTICING STANDARDS,BUILDING CODES, AND MANUFACTURERS' INSTRUCTIONS AND SPECIFICATIONS.
8. THE GENERAL CONTRACTOR SHALL SUBMIT COLOR SAMPLES ON ALL FINISHMATERIALS FOR APPROVAL BEFORE ORDERING.
9. ALL INTERIOR DIMENSIONS ARE MEASURED FROM FINISH FACE TO FINISH FACE, UNLESSOTHERWISE NOTED.
10. ALL INTERIOR PARTITIONS SHALL BE BRACED TO THE FLOOR/ROOF STRUCTURALMEMBERS, UNLESS OTHERWISE NOTED.
11. EACH DESIGN DISCIPLINE WILL BE THE PRIMARY SOURCE FOR INFORMATIONREGARDING THAT SUBJECT (ARCHITECTURAL, STRUCTURAL, MECHANICAL,ELECTRICAL, ETC.) HOWEVER, IT WILL NOT BE THE ONLY SOURCE OF COORDINATION,INFORMATION OF DIMENSIONS, DETAILING AND FINISHED APPEARANCE, OR TRIMFEATURES. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW AND COORDINATION OFRELATED DESIGN DOCUMENTATION.
12. REFER TO GENERAL NOTES TO EACH SERIES (FLOOR PLAN, ELEVATIONS, ETC.)CONTAINED IN SET SERIES.
13. ALL PIPE WORK AND CONDUIT PENETRATING FLOOR SLABS AND WALLS SHALL BESLEEVED EXCEPT WHERE SHAFTS OR OPENINGS ARE PROVIDED. VOIDS WITHINSLEEVES SHALL BE FIRE STOPPED AS SPECIFIED.
14. MECHANICAL ELECTRICAL AND PLUMBING TRADES SHALL BE RESPONSIBLE FORPROPER SETTING OF SLEEVES AND BOXES FOR THEIR RESPECTIVE WORK IN FLOORS ORWALLS SQUARE AND FLUSH.
15. LOCATE SUSPENDED CEILING HANGERS AND CHANGES TO AVOID CONFLICT WITHOTHER TRADES. PROVIDE PROPER SPACE FOR RECESSED LIGHT FIXTURES, SPRINKLERLINES, DUCTWORK, TECHNOLOGY AND WIRING RUNS, ETC. SEE REFLECTED CEILINGPLANS, MECHANICAL AND ELECTRICAL DRAWINGS FOR LOCATION OF AFFECTEDDEVICES. CEILING LAYOUT FOR FINISHED SUSPENDED CEILINGS ARE SHOWN ONREFLECTED CEILING PLANS AND SHALL GOVERN THE LOCATION OF LIGHT FIXTURESDIFFUSERS, SPRINKLER HEADS, ETC.
16. REVIEW ALL INFORMATION FOR EACH AREA OF WORK BEFORE PROCEEDING.
17. ALL FLOOR DRAINS SHALL BE LOCATED AT THE LOWEST POINT IN THE AREA ANDSHALL ALLOW FOR POSITIVE DRAINAGE OF THE SURROUNDING AREA.
18. ALL PIPING AND CONDUIT ARE TO BE CONTAINED WITHIN PARTITIONS UNLESS NOTEDOTHERWISE IN THE DOCUMENTS. IF ADDITIONAL FURROUTS ARE REQUIRED THEY WILLBE LOCATED IN THE NEAREST INSIDE CORNER.
19. THE DOCUMENTS ARE ADDRESSED TO THE GENERAL CONTRACTOR AND ITS WORKREGARDLESS OF THE EXTENT OF THE SUBCONTRACTOR OR DIVISION OF THE WORK BYSUBCONTRACTOR OR TRADES.
20. THE DRAWINGS ARE DIAGRAMMATIC AND ARE INTENDED TO DEFINE THE EXTENT OFTHE RELOCATION OF THE VARIOUS PARTS OF WORK TO EACH OTHER AND PROVIDE AWHOLE AND OPERATIONAL SYSTEM.
21. INFORMATION SHOWN ON THESE DOCUMENTS SHOULD BE SUPPORTED BY THECORRESPONDING ENGINEER'S DOCUMENTS. IF DISCREPANCIES OCCUR BETWEENDOCUMENTS AND EXISTING CONDITIONS, THE CONTRACTOR IS RESPONSIBLE FORVERIFYING WITH THE ARCHITECT BEFORE PROCEEDING WITH PRICING OR WORK.
22. IF ANY FIXTURES CANNOT BE INSTALLED AS SHOWN ON PLANS DUE TO CONFLICTSWITH STRUCTURE, MECHANICAL OR ELECTRICAL EXISTING BUILDING ELEMENTS, VERIFYCONDITION WITH THE ARCHITECT BEFORE PROCEEDING.
23. LOCATE ELECTRICAL RECEPTACLES AT LEAST 15" A.F.F. IN COMPLIANCE WITH TEXASACCESSIBILITY STANDARDS. LOCATE CONTROLS AND SWITCHES AT MOST 48" A.F.F.,OR AT MOST 44" A.F.F. WHEN LOCATED OVER AN OBSTRUCTION.
24. ALL NEW CONTROL DEVICES AND OPERATING MECHANISMS MUST BE FURNISHEDAND INSTALLED IN CONFORMANCE WITH REQUIREMENTS OF THE AMERICANS WITHDISABILITIES ACT ACCESSIBILITY GUIDELINES AND THE TEXAS ACCESSIBILITYSTANDARDS.
25. CONTRACTOR SHALL INCLUDE ALL BACKING AND REINFORCEMENT NECESSARY INTHE PARTITION FOR SCHEDULED FIXTURES, MILLWORK, ETC.
INDEX OF DRAWINGSGENERAL
COVER SHEETA0.0 INDEX OF DRAWINGS, GENERAL NOTES, KEY TO SYMBOLS, ABBREVIATIONSA0.1 ADA DETAILSA0.2 CODE REVIEW SHEET, EGRESS PLAN
LEGEND
ARCHITECTURAL
A1.1 DEMOLITION PLANA1.2 RCP DEMOLITIONA2.1 NEW FLOOR PLAN AND FINISH SCHEDULEA2.2 ENLARGED PLANSA2.3 NEW RCPA5.1 PARTITION TYPES AND DETAILSA6.1 INTERIOR ELEVATIONSA9.1 MILLWORK SECTION AND DETAILS
MECHANICAL
M-001 SCHEDULES, NOTES AND LEGENDSM-101 DEMOLITION FLOOR PLANM-201 PROPOSED FLOOR PLAN
PLUMBING
P-1.1 SCHEDULES, NOTES AND LEGENDP-2.1 DEMOLITION FLOOR PLANEP-3.1 PROPOSED FLOOR PLAN
4'-0"SLAB
ENLARGED DETAIL REFERENCE
DOOR NUMBER (SAME NUMBER AS ROOMWITH LETTER FOR MULTIPLE DOORS)
NORTH ARROW
ELEVATION REFERENCE BUILDING SECTION, SECTION DETAIL
XAX.XX
X/A
XXX
REF: AX.XX FOR CONTINUATIONREF: AX.XX FOR CONTINUATION
MATCH LINE
REVISION NUMBER AND AFFECTED AREA
STRUCTURAL SLAB / FIN. FLR. ELEVATION VERTICAL ELEVATION
REFERENCE TO NOTES TO DRAWINGDIMENSION LINES
555
ROOM NUMBERS & NUMBERWINDOW TYPE
P ROOM NAMERM #
PARTITION TYPE
A101A 3
TOILET ACCESSORY
A
N (PLAN NORTH )TN (TRUE NORTH )
X/A3.20 SIM.
4'-0"
DATE
ISSUE LOG
DESCRIPTIONNO.
CONSULTANT:
SEAL:
5900 TEAGUE RD.
PROJECT NAME :
TEAGUE
ADMINISTRATION BUILDING
DEPARTMENT
CITY OF HOUSTON
GENERAL SERVICES
DATE :
SCALE :
DRAWN BY :
CHECKED BY :
SHEET TITLE :
SHEET NO. :
PROJECT NO.:
AM
[0"=0'-0" / AS SHOWN]
[10/26/15]
AS
WBS NO:S-000020-0007-3-01-02
1 10/05/15 DESIGN PHASE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
PLANNING & DEVELOPMENT
WATER ENGINEERING
WASTEWATER ENGINEERING
APPROVALS
STORMWATER ENGINEERING
TRAFFIC AND TRANSPORTATION
STREET, BRIDGE & ROW ENG.
1449.15
INTERIOR RENOVATIONS
2 10/27/15 95% CD REVIEW
PROZIGN701 Shepherd, Suite 200 | Houston, TX 77007P ( 7 1 3 ) 9 7 7 - 6 0 6 0 | F ( 7 1 3 ) 9 7 7 - 6 0 8 6
A R C H I T E C T S
MEP:INFRASTRUCTURE ASSOCIATES
Firm No. F-4506
6 1 1 7 R i c h m o n d A v e . , S u i t e 2 0 0H o u s t o n , T X 7 7 0 0 7P ( 7 1 3 ) 6 2 2 - 0 1 2 0 | F ( 7 1 3 ) 6 2 2 - 0 5 5 7
DESIGN
3 11/30/15 100% CD REVIEW
INDEX OF DRAWINGS
GENERAL NOTES
A0.0
LEGEND
ABBREVIATIONS
XA.XX
XX
XX
XX
XX
4
1
2
3
3
3
3
3
3
3
3
3 3
3
3
3
3
3
3
3
3
4
4
4
4
44
4 4
4
4
4
4
4
4
4
4
4
3
6
5
5
5
5
6
3
DATE
ISSUE LOG
DESCRIPTIONNO.
CONSULTANT:
SEAL:
5900 TEAGUE RD.
PROJECT NAME :
TEAGUE
ADMINISTRATION BUILDING
DEPARTMENT
CITY OF HOUSTON
GENERAL SERVICES
DATE :
SCALE :
DRAWN BY :
CHECKED BY :
SHEET TITLE :
SHEET NO. :
PROJECT NO.:
AM
[0"=0'-0" / AS SHOWN]
[10/26/15]
AS
WBS NO:S-000020-0007-3-01-02
1 10/05/15 DESIGN PHASE
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
PLANNING & DEVELOPMENT
WATER ENGINEERING
WASTEWATER ENGINEERING
APPROVALS
STORMWATER ENGINEERING
TRAFFIC AND TRANSPORTATION
STREET, BRIDGE & ROW ENG.
1449.15
INTERIOR RENOVATIONS
2 10/27/15 95% CD REVIEW
PROZIGN701 Shepherd, Suite 200 | Houston, TX 77007P ( 7 1 3 ) 9 7 7 - 6 0 6 0 | F ( 7 1 3 ) 9 7 7 - 6 0 8 6
A R C H I T E C T S
MEP:INFRASTRUCTURE ASSOCIATES
Firm No. F-4506
6 1 1 7 R i c h m o n d A v e . , S u i t e 2 0 0H o u s t o n , T X 7 7 0 0 7P ( 7 1 3 ) 6 2 2 - 0 1 2 0 | F ( 7 1 3 ) 6 2 2 - 0 5 5 7
DESIGN
3 11/30/15 100% CD REVIEW
KEY NOTES
GENERAL NOTES
1. NEW NON-POROUS CEILING TILES AND CEILING GRID.2. RELOCATED LIGHT FIXTURE.3. NEW RETURNS AND SUPPLY GRILLS, TYP., RE: MEP4. EXISTING LIGHTING TO REMAIN UNLESS OTHERWISE NOTED, TYP.5. NEW FURRDOWN6. EXISTING FURRDOWN TO REMAIN.
1. ALL SURFACES TO BE PATCHED IN DAMAGED AREAS,CLEANED AND PREPARED FOR NEW FINISHES.
Username:
ALEX MARTINEZ
Date/Time:
11/25/2015 2:30 PM
Filename:
P:\41136\[projects]\1449.15 Teague Admin. Bldg Interior Inprovements\Drawings\CDs\A20_1NC Plan.dwg
01OVERALL NEW RCP1/16"=1'-0"
NEW RCP
A2.3
02 ENLARGED - NEW RCP 1/4"=1'-0"