Space available: 115,656 RSF (divisible). 1st floor: 64,487 RSF; 2nd floor: 51,169 RSF
Year completed: 1981 Site area: 34.4 acres
Building size: 437,715 RSF Floors: Two floors and partial basement
Parking: Currently 627 stalls. Potential parking revision (see page 5) will provide an estimated 4 stalls per 1000 RSF.
Ceiling heights: Office area and conference rooms are typically 9’6”. Lab spaces are typically 9’0”.
Loading docks: Two loading docks with 18 grade level bays
Foundation and frame: Concrete with concrete columns and beams
Exterior walls: Floor-to-ceiling glass window walls of 4’ x 12’ panes
HVAC: Offices & Common Areas: Two VAV main supply air fan systems serving VAV terminal zones with re-heat in each office area, associated exhaust/return air fans controlled by Metasys building management system computer.
Chillers: Three total. One 600-ton Trane chiller model CVHF 640 (R-123), and one 600-ton York chiller model HT K2 E3-ECBS (R-11), and one 300-ton Trane chiller model CVHE 320 (R-123). All are centrifugal chillers serving R&D special systems as well as mechanical system needs.
Boilers: Two total. One 600HP, 25MM BTU/hour Cleaver Brooks model CB-200-600; one 300HP, 12.5 MM BUT/hour Thomasville Boiler, model IR 3WB 300 G02, providing up to 200 psi steam for R&D use and building mechanical system needs.
Mechanical System Operations:
Building mechanical systems are controlled by a seven-day time program via a Metasys building management system and an occupied schedule. The two main office area supply and exhaust fan systems are VFD controlled, VAV with terminal reheat zones, and operate on a start/stop schedule five days per week, and utilize mixing dampers for “free cooling” to the extent possible.
Electrical System: • Six 1,500 KVA 12,470V - 277/480V transformers and one 2,500 KVA 12,470V - 1,386/2,400V transformer serving various loads and areas of the facility.
• One 1,250KVA Caterpillar 3508 generator serving life safety systems and standby power needs
Elevators: Five elevators, all Montgomery hydraulic. • One passenger elevator (basement to roof ): 5,250 lbs. capacity• One passenger elevator (basement to second floor): 5,250 lbs. capacity• One passenger elevator (basement to first floor): 5,250 lbs. capacity• Two large (12’ x 12’) freight elevators (basement to second floor): 7,500 lbs capacity
Fire alarm & sprinklers: • Cerebus Pyrotronics model MXL fire alarm panel with PA functions• Fully sprinkled building with wet and dry systems, one electric fire pump, one diesel
fire pump
East Campus tECh CEntEr32901 Weyerhaeuser Way s Federal Way, Washington
East Campus tECh CEntEr FaCt shEEt
East Campus tECh CEntEr
32901 Weyerhaeuser Way S • Federal Way, WA 98001
L EASED
First Floor
64,487 RSF available
32901 Weyerhaeuser Way S • Federal Way, WA 98001
East Campus tECh CEntEr
L EASED
Second Floor
51,169 RSFAvailable
East Campus tECh CEntEr32901 Weyerhaeuser Way s Federal Way, Washington
Potential Parking reconfiguration
GREENLINE*
TECHCENTER
* Former Weyerhaeuser headquarters
FederalWay
TransitCenter
Park&
Ride
North Lake
Federal WayCrossings
RhododendronSpecies Garden
Paci�cBonsai
Museum
Celebration Park
Park&
Ride
5
1818
S 320th Street
S 317th Street
Paci
fc H
ighw
ay S
S 320th Street
Military Road S
99
Weyerh
aeus er W
ay S
99
Weyerh
aeuser Way S
S 336th Street
S 348th Street
East Campus tECh CEntEr32901 Weyerhaeuser Way s Federal Way, Washington
East Campus tECh CEntEr ViCinity map
For further information or to schedule a tour, please contact our exclusive leasing agents:
Michael Hemphill206-336-5325mhemphill@andoverco.com
Jim Bisset206-336-5334jbisset@andoverco.com
Brian Bruininks, CCIM206-336-5324bbruininks@andoverco.com
THE ANDOVER COMPANY, INC.C O R F A C I N T E R N A T I O N A L