East Campus ECh CEntEr - seaofficespaces.com

7
E AST C AMPUS T ECH C ENTER THE ANDOVER COMPANY, INC. C O R FA C I N T E R N AT I O N A L

Transcript of East Campus ECh CEntEr - seaofficespaces.com

East Campus

tECh CEntEr

THE ANDOVER COMPANY, INC.C O R F A C I N T E R N A T I O N A L

Space available: 115,656 RSF (divisible). 1st floor: 64,487 RSF; 2nd floor: 51,169 RSF

Year completed: 1981 Site area: 34.4 acres

Building size: 437,715 RSF Floors: Two floors and partial basement

Parking: Currently 627 stalls. Potential parking revision (see page 5) will provide an estimated 4 stalls per 1000 RSF.

Ceiling heights: Office area and conference rooms are typically 9’6”. Lab spaces are typically 9’0”.

Loading docks: Two loading docks with 18 grade level bays

Foundation and frame: Concrete with concrete columns and beams

Exterior walls: Floor-to-ceiling glass window walls of 4’ x 12’ panes

HVAC: Offices & Common Areas: Two VAV main supply air fan systems serving VAV terminal zones with re-heat in each office area, associated exhaust/return air fans controlled by Metasys building management system computer.

Chillers: Three total. One 600-ton Trane chiller model CVHF 640 (R-123), and one 600-ton York chiller model HT K2 E3-ECBS (R-11), and one 300-ton Trane chiller model CVHE 320 (R-123). All are centrifugal chillers serving R&D special systems as well as mechanical system needs.

Boilers: Two total. One 600HP, 25MM BTU/hour Cleaver Brooks model CB-200-600; one 300HP, 12.5 MM BUT/hour Thomasville Boiler, model IR 3WB 300 G02, providing up to 200 psi steam for R&D use and building mechanical system needs.

Mechanical System Operations:

Building mechanical systems are controlled by a seven-day time program via a Metasys building management system and an occupied schedule. The two main office area supply and exhaust fan systems are VFD controlled, VAV with terminal reheat zones, and operate on a start/stop schedule five days per week, and utilize mixing dampers for “free cooling” to the extent possible.

Electrical System: • Six 1,500 KVA 12,470V - 277/480V transformers and one 2,500 KVA 12,470V - 1,386/2,400V transformer serving various loads and areas of the facility.

• One 1,250KVA Caterpillar 3508 generator serving life safety systems and standby power needs

Elevators: Five elevators, all Montgomery hydraulic. • One passenger elevator (basement to roof ): 5,250 lbs. capacity• One passenger elevator (basement to second floor): 5,250 lbs. capacity• One passenger elevator (basement to first floor): 5,250 lbs. capacity• Two large (12’ x 12’) freight elevators (basement to second floor): 7,500 lbs capacity

Fire alarm & sprinklers: • Cerebus Pyrotronics model MXL fire alarm panel with PA functions• Fully sprinkled building with wet and dry systems, one electric fire pump, one diesel

fire pump

East Campus tECh CEntEr32901 Weyerhaeuser Way s Federal Way, Washington

East Campus tECh CEntEr FaCt shEEt

East Campus tECh CEntEr

32901 Weyerhaeuser Way S • Federal Way, WA 98001

L EASED

First Floor

64,487 RSF available

32901 Weyerhaeuser Way S • Federal Way, WA 98001

East Campus tECh CEntEr

L EASED

Second Floor

51,169 RSFAvailable

East Campus tECh CEntEr32901 Weyerhaeuser Way s Federal Way, Washington

Potential Parking reconfiguration

GREENLINE*

TECHCENTER

* Former Weyerhaeuser headquarters

FederalWay

TransitCenter

Park&

Ride

North Lake

Federal WayCrossings

RhododendronSpecies Garden

Paci�cBonsai

Museum

Celebration Park

Park&

Ride

5

1818

S 320th Street

S 317th Street

Paci

fc H

ighw

ay S

S 320th Street

Military Road S

99

Weyerh

aeus er W

ay S

99

Weyerh

aeuser Way S

S 336th Street

S 348th Street

East Campus tECh CEntEr32901 Weyerhaeuser Way s Federal Way, Washington

East Campus tECh CEntEr ViCinity map

For further information or to schedule a tour, please contact our exclusive leasing agents:

Michael [email protected]

Jim [email protected]

Brian Bruininks, [email protected]

THE ANDOVER COMPANY, INC.C O R F A C I N T E R N A T I O N A L