Post on 28-Jul-2018
DO
CU
ME
NT
November 2016Application Ref: EN020017
Design Drawings
4.14(B)
National Grid (Richborough Connection Project) OrderRegulation 5(2)(o) of the Infrastructure Planning(Applications: Prescribed Forms and Procedure) Regulations 2009 and TEN-E Regulation EU347/2013
TERMINAL PYLONDOUBLE CIRCUIT400kV OPERATIONMAXIMUM HEIGHT
LOW HEIGHTLATTICE PYLONDOUBLE CIRCUIT400kV OPERATIONMINIMUM HEIGHT
LOW HEIGHTLATTICE PYLONDOUBLE CIRCUIT400kV OPERATIONMAXIMUM HEIGHT
STANDARD LATTICE PYLONDOUBLE CIRCUIT400kV OPERATIONMINIMUM HEIGHT
STANDARD LATTICE PYLONDOUBLE CIRCUIT400kV OPERATIONMAXIMUM HEIGHT
7.75
38
.3
0
29.20
10.40
44
.4
0
29.50
9.60
43
.8
2
17.53
11.43
61
.0
6
17.07
19.51
16.31
60
.8
0
Date Remarks Checked ApprovedDrawn
Notes
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER DESIGN
DRAWINGS REGULATIONS 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 1 OF 21
MAXIMUM AND MINIMUM
PYLON HEIGHTS
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 1 OF 21
MAXIMUM AND MINIMUM PYLON HEIGHTS
EN020017
PDD-21497-2-OHL-0051
Not to Scale A1 1 of 21 S.56
1. All dimensions in metres unless otherwise stated.
2. All dimensions are indicative and may change subject
to article 5 (Limits of Deviation) of the DCO (Volume 2,
Document 2.1)
A 16/12/2014 S.42 Consultation ETW ROS SS
B 01/12/2015 S.56 Application
ETW ROS SS
C 26/08/2016
CT PF ROS
S.56 Application
0 100 200 300 400 500 600 700 800 900 1000
-100
0
100
-100
0mOD
100
Pa
th
Rive
r S
to
ur
Ca
nte
rb
ury S
ew
ag
e P
ip
e
(E
xa
ct lo
ca
tio
n T
BD
)
Rive
r S
to
ur
Pa
th
Pa
th
Va
uxh
all R
oa
d
MP
G
as P
ip
elin
e (E
xa
ct
po
sitio
n T
BD
)
Existin
g L
V L
in
e
Existin
g L
V L
in
e
Ra
ilw
ay
Pu
blic R
ig
ht o
f W
ay
Existin
g L
V L
in
e
Canterbury Gantry
PC1
PC2
PC3
PC4
Canterbury Gantry
PC1
PC2
PC3
PC4
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 2 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 2 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0401
1:2000 A1 2 of 21 S.56
B 01/12/2015 S.56 Application ETW
PROFILE CANTERBURY GANTRY TO PC4
SCALE 1:2000
PLAN CANTERBURY GANTRY TO PC4
SCALE 1:2000
ROS SS
1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100
-100
0
100
-100
100
Te
le
co
m L
in
e
Sh
allo
ak R
oa
d
Lyn
ne
W
oo
d
Wa
ll
Existin
g L
V L
in
e
HP
G
as P
ip
elin
e (E
xa
ct p
ositio
n T
BD
)
Lyn
ne
W
oo
d
Dra
in
PX
1
32
kV
R
ou
te
- T
o b
e
te
mp
ora
rily d
ive
rte
d
Existin
g L
V L
in
e
Pu
blic R
ig
ht o
f W
ay
Pa
th
Te
mp
ora
ry S
tru
ctu
re
s (P
olytu
nn
els)
Tra
ck
Te
mp
ora
ry S
tru
ctu
re
s (P
olytu
nn
els)
Pa
th
Pu
blic R
ig
ht o
f W
ay
PC4
PC5 PC6
PC7
PC4
PC5
PC6
PC7
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 3 OF 21
PLAN AND PROFILE DRAWINGS
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 3 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0402
1:2000 A1 3 of 21 S.56
B 01/12/2015 S.56 Application
ETW
PROFILE CANTERBURY PC4 TO PC7
SCALE 1:2000
PLAN CANTERBURY PC4 TO PC7
SCALE 1:2000
ROS SS
2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300
-100
0
100
-100
100
Tra
ck
Existin
g L
V L
in
e
Ro
ad
(M
ayto
n L
an
e)
T
ele
co
m L
in
e
Pu
blic R
ig
ht o
f W
ay
Dra
in
Existin
g L
V L
in
e
Ro
ad
(B
arn
ets L
an
e)
PC7
PC8
PC9
PC10
PC7
PC8
PC9
PC10
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 4 OF 21
PLAN AND PROFILE DRAWINGS
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 4 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0403
1:2000 A1 4 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC7 TO PC10
SCALE 1:2000
PLAN CANTERBURY PC7 TO PC10
SCALE 1:2000
ETW ROS SS
3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400
-100
0
100
-100
100
Dra
in
Dra
in
Dra
in
Se
we
r p
ip
e (E
xa
ct p
ositio
n T
BD
)
Se
we
r p
ip
e (E
xa
ct p
ositio
n T
BD
)
Ro
ad
(H
ern
e B
ay R
oa
d - A
29
1)
Se
we
r p
ip
e (E
xa
ct p
ositio
n T
BD
)
Tra
ck
Tra
ck
Po
nd
Ke
mb
erla
nd
W
oo
d
Tra
ck
Se
wa
ge
p
ip
e (E
xa
ct
Po
sitio
n T
BD
)
Pa
th
Pu
blic R
ig
ht o
f W
ay
PC10
PC11
PC12
PC13
PC10
PC11
PC12
PC13
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 5 OF 21
PLAN AND PROFILE DRAWINGS
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 5 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0404
1:2000 A1 5 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC10 TO PC13
SCALE 1:2000
PLAN CANTERBURY PC10 TO PC13
SCALE 1:2000
ETW ROS SS
4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400
-100
0
100
-100
100
LP
G
as P
ip
elin
e (E
xa
ct
Po
sitio
n T
BD
)
Ho
ath
R
oa
d
SW
W
ate
r P
ip
elin
e
(E
xa
ct p
ositio
n T
BD
)
Te
le
co
m L
in
e
PC13 PC14
PC15
PC16
PC13 PC14 PC15 PC16
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 6 OF 21
PLAN AND PROFILE DRAWINGS
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 6 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0405
1:2000 A1 6 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC13 TO PC16
SCALE 1:2000
PLAN CANTERBURY PC13 TO PC16
SCALE 1:2000
ETW ROS SS
5400 5500 5600 5700 5800 5900 6000 6100 6200 6300 6400 6500
-100
0
100
-100
100
Ro
ad
(B
re
dla
nd
s L
an
e)
Existin
g L
V L
in
e
Dra
in
Rive
r
Tra
ck
PC16
PC17
PC18
PC19
PC16
PC17PC18 PC19
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 7 OF 21
PLAN AND PROFILE DRAWINGS
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 7 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0406
1:2000 A1 7 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC16 TO PC19
SCALE 1:2000
PLAN CANTERBURY PC16 TO PC19
SCALE 1:2000
ETW ROS SS
6600 6700 6800 6900 7000 7100 7200 7300 7400 7500 7600
-100
0
100
-100
100
Rive
r
Pu
blic R
ig
ht o
f w
ay
Pu
blic R
ig
ht o
f w
ay
Tra
ck
PC19
PC20
PC21
PC22
PC19
PC20
PC21 PC22
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 8 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 8 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0407
1:2000 A1 8 of 21 S.56
B 01/12/2015 S.56 Application
ETW
PROFILE CANTERBURY PC19 TO PC22
SCALE 1:2000
PLAN CANTERBURY PC19 TO PC22
SCALE 1:2000
ROS SS
7600 7700 7800 7900 8000 8100 8200 8300 8400 8500 8600 8700 8800
-100
0
100
-100
100
Dra
in
Tra
ck
Po
nd
Dra
in
Dra
in
Pu
blic R
ig
ht o
f w
ay
Dra
in
Tra
ck
Wa
ll
Pu
blic R
ig
ht o
f W
ay
Brid
ge
Tra
ck
Rive
r - N
eth
erg
on
g P
en
n
Dra
in
Dra
in
PC22
PC23
PC24
PC25
PC22 PC23
PC24
PC25
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 9 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 9 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0408
1:2000 A1 9 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC22 TO PC25
SCALE 1:2000
PLAN CANTERBURY PC22 TO PC25
SCALE 1:2000
ETW ROS SS
8800 8900 9000 9100 9200 9300 9400 9500 9600 9700 9800
-100
0
100
-100
100
Dra
in
Dra
in
Ro
ad
(S
an
dp
it H
ill)
Dra
in
Up
stre
et W
S
ew
ag
e P
ip
e
(E
xa
ct p
ositio
n T
BD
)
Existin
g L
V L
in
e
Dra
in
Dra
in
PC25 PC26
PC27
PC28
PC25 PC26 PC27
PC28
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 10 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 10 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0409
1:2000 A1 10 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC25 TO PC28
SCALE 1:2000
PLAN CANTERBURY PC25 TO PC28
SCALE 1:2000
ETW ROS SS
9900 10000 10100 10200 10300 10400 10500 10600 10700 10800
-100
0
100
-100
100
Dra
in
Rive
r (S
arre
P
en
)
Pu
blic F
oo
tp
ath
Dra
in
Tra
ck
Dra
in
Dra
in
PC28
PC29 PC30
PC31
PC28
PC29 PC30 PC31
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 11 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 11 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-410
1:2000 A1 11 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC28 TO PC31
SCALE 1:2000
PLAN CANTERBURY PC28 TO PC31
SCALE 1:2000
ETW ROS SS
10900 11000 11100 11200 11300 11400 11500 11600 11700 11800
-100
0
100
-100
100
Dra
in
Dra
in
Dra
in
Existin
g L
V L
in
e
Dra
in
Rive
r (S
eve
nsco
re
D
ike
)
Fo
otb
rid
ge
Dra
in
Dra
in
PC31 PC32
PC33
PC34
PC31 PC32
PC33
PC34
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 12 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 12 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0411
1:2000 A1 12 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC31 TO PC34
SCALE 1:2000
PLAN CANTERBURY PC31 TO PC34
SCALE 1:2000
ETW ROS SS
11900 12000 12100 12200 12300 12400 12500 12600 12700 12800 12900
-100
0
100
-100
100
Existin
g 1
32
kV
(P
X)
Ove
rh
ea
d lin
e
(to
b
e te
mp
ora
rily
dive
rte
d)
Existin
g L
V L
in
e
SW
W
ate
r P
ip
e (E
xa
ct
po
sitio
n T
BD
)
Dra
in
Ro
ad
A
28
(Isla
nd
R
oa
d)
Dra
in
Dra
in
LH
P G
as P
ip
e (E
xa
ct
po
sitio
n T
BD
)
Dra
in
Ra
ilw
ay
Dra
in
Dra
in
Dra
in
Dra
in
PC34 PC35
PC36 PC37
PC34 PC35 PC36 PC37
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 13 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 13 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0412
1:2000 A1 13 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC34 TO PC37
SCALE 1:2000
PLAN CANTERBURY PC34 TO PC37
SCALE 1:2000
ETW ROS SS
12900 13000 13100 13200 13300 13400 13500 13600 13700 13800 13900
-100
0
100
-100
100
Tra
ck
Rive
r W
an
tsu
m
Dra
in
Dra
in
Dra
in
Dra
in
Dra
in
Dra
in
PC37
PC38 PC39
PC40
North
PC37 PC38 PC39 PC40
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 14 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 14 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0413
1:2000 A1 14 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC37 TO PC40
SCALE 1:2000
PLAN CANTERBURY PC37 TO PC40
SCALE 1:2000
ETW ROS SS
14000 14100 14200 14300 14400 14500 14600 14700 14800 14900 15000
-100
0
100
-100
100
SW
W
ate
r p
ip
e
(E
xa
ct p
ositio
n T
BD
)
Ro
ad
(G
ore
S
tre
et)
MP
G
as P
ip
elin
e
(E
xa
ct p
ositio
n T
BD
)
Pa
th
/ P
ub
lic R
ig
ht o
f w
ay
Dra
in
HP
G
as P
ip
elin
e
(E
xa
ct p
ositio
ns T
BD
)
Dra
in
Dra
in
Dra
in
We
ste
rn
M
on
kto
n
Stre
am
(D
ra
in
)
PX
1
32
kV
R
ou
te
- T
o b
e
te
mp
ora
rily d
ive
rte
d
PC40
PC41
PC42
PC43
PC40 PC41 PC42 PC43
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 15 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 15 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0414
1:2000 A1 15 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC40 TO PC43
SCALE 1:2000
PLAN CANTERBURY PC40 TO PC43
SCALE 1:2000
ETW ROS SS
15100 15200 15300 15400 15500 15600 15700 15800 15900 16000
-100
0
100
-100
100
PY
1
32
kV
R
ou
te
- T
o b
e
te
mp
ora
rily d
ive
rte
d
Pu
blic R
ig
ht o
f W
ay
Dra
in
Dra
in
Dra
in
Dra
in
SW
W
ate
r p
ip
e
(E
xa
ct p
ositio
n T
BD
)
PC43
PC44
PC45
PC46
PC43
PC44
PC45 PC46
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 16 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 16 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0415
1:2000 A1 16 of 21 S.56
B 01/12/2015 S.56 Application
ETW
PROFILE CANTERBURY PC43 TO PC46
SCALE 1:2000
PLAN CANTERBURY PC43 TO PC46
SCALE 1:2000
SSROS
16100 16200 16300 16400 16500 16600 16700 16800 16900 17000 17100
-100
0
100
-100
100
Tra
ck
Min
ste
r S
tre
am
(D
ra
in
)
Dra
in
Dra
in
Dra
in
Min
ste
r M
arsh
es
Dra
in
Dra
in
Pu
blic R
ig
ht o
f W
ay
PC46
PC47
PC48
PC49
PC46 PC47 PC48 PC49
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 17 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 17 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0416
1:2000 A1 17 of 21 S.56
B 01/12/2015 S.56 Application
ETW
PROFILE CANTERBURY PC46 TO PC49
SCALE 1:2000
PLAN CANTERBURY PC46 TO PC49
SCALE 1:2000
ROS
SS
17200 17300 17400 17500 17600 17700 17800 17900 18000 18100 18200
-100
0
100
-100
100
Dra
in
Dra
in
Tra
ck (A
bb
ots W
all)
Min
ste
r M
arsh
es
Dra
in
Re
stricte
d B
yw
ay
(M
arsh
F
arm
R
oa
d)
Dra
in
Existin
g L
V L
in
e
Pu
blic R
ig
ht o
f W
ay
Rive
r S
to
ur
Pu
blic R
ig
ht o
f W
ay
PC49
PC50
PC51
PC52
PC49 PC50 PC51 PC52
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 18 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 18 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0417
1:2000 A1 18 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC49 TO PC52
SCALE 1:2000
PLAN CANTERBURY PC49 TO PC52
SCALE 1:2000
ETW ROS SS
18300 18400 18500 18600 18700 18800 18900 19000 19100 19200 19300
-100
0
100
-100
100
Dra
in
Dra
in
Dra
in
Existin
g L
V L
in
e
Dra
in
Dra
in
Dra
in
PC52
PC53
PC54 PC55
PC52 PC53 PC54 PC55
0mOD
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 19 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 19 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0418
1:2000 A1 19 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC52 TO PC55
SCALE 1:2000
PLAN CANTERBURY PC52 TO PC55
SCALE 1:2000
ETW ROS SS
19400 19500 19600 19700 19800 19900 20000 20100 20200 20300 20400 20500 20600
-100
0
100
Dra
in
Tra
ck
Dra
in
Dra
in
SW
W
ate
r P
ip
elin
e (E
xa
ct
po
sitio
n T
BD
)
Dra
in
Dra
in
Dra
in
Ra
ilw
ay
Dra
in
Dra
in
Wa
ll
Dra
in
Tra
ck
PC55 PC56
PC57 PC58
PC59
PC60
PC55 PC56
PC57
PC58
PC59
PC
60
Richborough PC Gantry
-100
100
Pu
blic R
ig
ht o
f W
ay
SW
W
ate
r P
ip
e (E
xa
ct
po
sitio
n T
BD
)
Rive
r S
to
ur
Richborough
PC Gantry
0mOD
20700
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
REPRODUCED FROM ORDNANCE SURVEY MAPS.
BY PERMISSION OF THE ORDNANCE SURVEY ON
BEHALF OF THE CONTROLLER HER MAJESTY'S
ORDNANCE SURVEY. OS LICENCE NO. 100024241
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 20 OF 21
PLAN AND PROFILE DRAWING
1. All dimensions are in metres.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
3. Plan and profiles show proposed 400kV pylon
locations and heights and are subject to change.
4. Proposed profiles based on statutory clearances and
estimates of future maintenance scaffolding.
5. Trees and vegetation are not shown for clarity.
Canterbury - Richborough Circuit 1
Canterbury - Richborough Circuit 2
Earthwire - 160mm Optical Ground Wire
8.1m Ground Clearance Line
Ground Line
Notes
Key
This drawing is scaled at paper size A1, therefore any
prints taken at smaller sizes will affect accuracy of the
measurement units and should not be scaled against.
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 20 OF 21
PLAN AND PROFILE DRAWING
A 16/12/2014 S.42 Consultation ETW ROSSS
EN020017
PDD-21497-2-OHL-0419
1:2000 A1 20 of 21 S.56
B 01/12/2015 S.56 Application
PROFILE CANTERBURY PC55 TO PC60
SCALE 1:2000
PLAN CANTERBURY PC55 TO PC60
SCALE 1:2000
ETW ROS SS
Date Remarks Checked ApprovedDrawn
COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC
Scale: Sheet size: Sheet: Status:
National Grid Drawing Ref:
Application Number:
Version history:
Version
NATIONAL GRID (RICHBOROUGH
CONNECTION PROJECT) ORDER
DESIGN DRAWINGS REGULATION 5(2)(o)
AND TEN-E REGULATION EU347/2013
SHEET 21 OF 21
STAKING TABLE
1. Height of PC8 ad PC9 have been determined using
existing ground levels from NG supplied survey data.
2. All dimensions are indicative and may change
subject to article 5 (Limits of Deviation) of the DCO
(Volume 2, Document 2.1).
Notes
NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER
DESIGN DRAWINGS
REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013
SHEET 21 OF 21
STAKING TABLE
EN020017
PDD-21497-2-OHL-0421
N/A A1 21 of 21 S.56
S.56 Application
A 01/12/2015
GJB ROS SS
Contact us
Call our Freephone number: 0800 157 7878
Visit our project website:www.richboroughconnection.co.uk
Send an email to: richboroughconnection@communitycomms.co.uk
Follow us on Twitter: @NGRichborough
Write to our freepost address at: FREEPOST RICHBCONNECTION
PDD-21497-2-OHL-0058-PDD-21497-2-OHL-0058PDD-21497-2-OHL-0051-OHL-0051PDD-21497-2-OHL-0401-PDD-21497-2-OHL-0401PDD-21497-2-OHL-0402-PDD-21497-2-OHL-0402PDD-21497-2-OHL-0403-PDD-21497-2-OHL-0403PDD-21497-2-OHL-0404-PDD-21497-2-OHL-0404PDD-21497-2-OHL-0405-PDD-21497-2-OHL-0405PDD-21497-2-OHL-0406-PDD-21497-2-OHL-0406PDD-21497-2-OHL-0407-PDD-21497-2-OHL-0407PDD-21497-2-OHL-0408-PDD-21497-2-OHL-0408PDD-21497-2-OHL-0409-PDD-21497-2-OHL-0409PDD-21497-2-OHL-0410-PDD-21497-2-OHL-0410PDD-21497-2-OHL-0411-PDD-21497-2-OHL-0411PDD-21497-2-OHL-0412-PDD-21497-2-OHL-0412PDD-21497-2-OHL-0413-PDD-21497-2-OHL-0413PDD-21497-2-OHL-0414-PDD-21497-2-OHL-0414PDD-21497-2-OHL-0415-PDD-21497-2-OHL-0415PDD-21497-2-OHL-0416-PDD-21497-2-OHL-0416PDD-21497-2-OHL-0417-PDD-21497-2-OHL-0417PDD-21497-2-OHL-0418-PDD-21497-2-OHL-0418PDD-21497-2-OHL-0419-PDD-21497-2-OHL-0419PDD-21497-2-OHL-0421-PDD-21497-2-OHL-0421