  • Drawing Reference Drawing Title

    Sheet No. Version

    PDD-21497-2-OHL-0051

    Dimensions of Typical Poles and Pylons

    1 of 21 B

    PDD-21497-2-OHL-0401

    Plan and Profile Drawing

    2 of 21 B

    PDD-21497-2-OHL-0402

    Plan and Profile Drawing

    3 of 21 B

    PDD-21497-2-OHL-0403

    Plan and Profile Drawing

    4 of 21 B

    PDD-21497-2-OHL-0404

    Plan and Profile Drawing

    5 of 21 B

    PDD-21497-2-OHL-0405

    Plan and Profile Drawing

    6 of 21 B

    PDD-21497-2-OHL-0406

    Plan and Profile Drawing

    7 of 21 B

    PDD-21497-2-OHL-0407

    Plan and Profile Drawing

    8 of 21 B

    PDD-21497-2-OHL-0408

    Plan and Profile Drawing

    9 of 21 B

    PDD-21497-2-OHL-0409

    Plan and Profile Drawing

    10 of 21 B

    PDD-21497-2-OHL-0410

    Plan and Profile Drawing

    11 of 21 B

    PDD-21497-2-OHL-0411

    Plan and Profile Drawing

    12 of 21 B

    PDD-21497-2-OHL-0412

    Plan and Profile Drawing

    13 of 21 B

    PDD-21497-2-OHL-0413

    Plan and Profile Drawing

    14 of 21 B

    PDD-21497-2-OHL-0414

    Plan and Profile Drawing

    15 of 21 B

    PDD-21497-2-OHL-0415

    Plan and Profile Drawing

    16 of 21 B

    PDD-21497-2-OHL-0416

    Plan and Profile Drawing

    17 of 21 B

    PDD-21497-2-OHL-0417

    Plan and Profile Drawing

    18 of 21 B

    PDD-21497-2-OHL-0418

    Plan and Profile Drawing

    19 of 21 B

    PDD-21497-2-OHL-0419

    Plan and Profile Drawing

    20 of 21 B

    PDD-21497-2-OHL-0421

    Staking Table

    21 of 21 A

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    DESIGN DRAWING REFERENCES

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    DRAWING REFERENCES

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0058

    N/A A1 1 of 1 S.56

    B 01/12/2015 S.56 Application

    ETWROS SS

  • STANDARDLATTICE PYLONDOUBLE CIRCUIT400kV OPERATION

    STANDARDEXISTING PYLONDOUBLE CIRCUIT132kV OPERATION

    LOW HEIGHTLATTICE PYLONDOUBLE CIRCUIT400kV OPERATION

    24

    .1

    6

    7.06

    35

    .3

    0

    10

    .2

    5

    10

    .2

    5

    5.00

    5.00

    2.50

    TEMPORARY 'H'WOODEN POLESINGLE CIRCUIT132kV OPERATIONEstimated typical height oftemporary diversions

    TEMPORARY SINGLEWOODEN POLESINGLE CIRCUIT132kV OPERATIONEstimated typical height oftemporary diversions

    LOW HEIGHTLATICE PYLONSINGLE CIRCUIT132kV OPERATION

    29.70

    5.00

    11

    .6

    5

    10.10

    Date Remarks Checked ApprovedDrawn

    Notes

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 1 OF 21

    DIMENSIONS OF TYPICAL POLES

    AND PYLONS

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 1 OF 21

    DIMENSIONS OF TYPICAL POLES AND PYLONS

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0051

    Not to Scale A1 1 of 21 S.56

    B 01/12/2015 S.56 Application

    ETW

    1. All dimensions in metres unless otherwise stated.

    ROS SS

  • 0 100 200 300 400 500 600 700 800 900 1000

    -100

    0

    100

    -100

    0mOD

    100

    Pa

    th

    Rive

    r S

    to

    ur

    Ca

    nte

    rb

    ury S

    ew

    ag

    e P

    ip

    e

    (E

    xa

    ct lo

    ca

    tio

    n T

    BD

    )

    Rive

    r S

    to

    ur

    Pa

    th

    Pa

    th

    Va

    uxh

    all R

    oa

    d

    MP

    G

    as P

    ip

    elin

    e (E

    xa

    ct

    po

    sitio

    n T

    BD

    )

    Existin

    g L

    V L

    in

    e

    Existin

    g L

    V L

    in

    e

    Ra

    ilw

    ay

    Pu

    blic R

    ig

    ht o

    f W

    ay

    Existin

    g L

    V L

    in

    e

    Canterbury Gantry

    PC1

    PC2

    PC3

    PC4

    Canterbury Gantry

    PC1

    PC2

    PC3

    PC4

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 2 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 2 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0401

    1:2000 A1 2 of 21 S.56

    B 01/12/2015 S.56 Application ETW

    PROFILE CANTERBURY GANTRY TO PC4

    SCALE 1:2000

    PLAN CANTERBURY GANTRY TO PC4

    SCALE 1:2000

    ROS SS

  • 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100

    -100

    0

    100

    -100

    100

    Te

    le

    co

    m L

    in

    e

    Sh

    allo

    ak R

    oa

    d

    Lyn

    ne

    W

    oo

    d

    Wa

    ll

    Existin

    g L

    V L

    in

    e

    HP

    G

    as P

    ip

    elin

    e (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Lyn

    ne

    W

    oo

    d

    Dra

    in

    PX

    1

    32

    kV

    R

    ou

    te

    - T

    o b

    e

    te

    mp

    ora

    rily d

    ive

    rte

    d

    Existin

    g L

    V L

    in

    e

    Pu

    blic R

    ig

    ht o

    f W

    ay

    Pa

    th

    Te

    mp

    ora

    ry S

    tru

    ctu

    re

    s (P

    olytu

    nn

    els)

    Tra

    ck

    Te

    mp

    ora

    ry S

    tru

    ctu

    re

    s (P

    olytu

    nn

    els)

    Pa

    th

    Pu

    blic R

    ig

    ht o

    f W

    ay

    PC4

    PC5 PC6

    PC7

    PC4

    PC5

    PC6

    PC7

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 3 OF 21

    PLAN AND PROFILE DRAWINGS

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 3 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0402

    1:2000 A1 3 of 21 S.56

    B 01/12/2015 S.56 Application

    ETW

    PROFILE CANTERBURY PC4 TO PC7

    SCALE 1:2000

    PLAN CANTERBURY PC4 TO PC7

    SCALE 1:2000

    ROS SS

  • 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 3300

    -100

    0

    100

    -100

    100

    Tra

    ck

    Existin

    g L

    V L

    in

    e

    Ro

    ad

    (M

    ayto

    n L

    an

    e)

    T

    ele

    co

    m L

    in

    e

    Pu

    blic R

    ig

    ht o

    f W

    ay

    Dra

    in

    Existin

    g L

    V L

    in

    e

    Ro

    ad

    (B

    arn

    ets L

    an

    e)

    PC7

    PC8

    PC9

    PC10

    PC7

    PC8

    PC9

    PC10

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 4 OF 21

    PLAN AND PROFILE DRAWINGS

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 4 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0403

    1:2000 A1 4 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC7 TO PC10

    SCALE 1:2000

    PLAN CANTERBURY PC7 TO PC10

    SCALE 1:2000

    ETW ROS SS

  • 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400

    -100

    0

    100

    -100

    100

    Dra

    in

    Dra

    in

    Dra

    in

    Se

    we

    r p

    ip

    e (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Se

    we

    r p

    ip

    e (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Ro

    ad

    (H

    ern

    e B

    ay R

    oa

    d - A

    29

    1)

    Se

    we

    r p

    ip

    e (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Tra

    ck

    Tra

    ck

    Po

    nd

    Ke

    mb

    erla

    nd

    W

    oo

    d

    Tra

    ck

    Se

    wa

    ge

    p

    ip

    e (E

    xa

    ct

    Po

    sitio

    n T

    BD

    )

    Pa

    th

    Pu

    blic R

    ig

    ht o

    f W

    ay

    PC10

    PC11

    PC12

    PC13

    PC10

    PC11

    PC12

    PC13

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 5 OF 21

    PLAN AND PROFILE DRAWINGS

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 5 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0404

    1:2000 A1 5 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC10 TO PC13

    SCALE 1:2000

    PLAN CANTERBURY PC10 TO PC13

    SCALE 1:2000

    ETW ROS SS

  • 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400

    -100

    0

    100

    -100

    100

    LP

    G

    as P

    ip

    elin

    e (E

    xa

    ct

    Po

    sitio

    n T

    BD

    )

    Ho

    ath

    R

    oa

    d

    SW

    W

    ate

    r P

    ip

    elin

    e

    (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Te

    le

    co

    m L

    in

    e

    PC13 PC14

    PC15

    PC16

    PC13 PC14 PC15 PC16

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 6 OF 21

    PLAN AND PROFILE DRAWINGS

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 6 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0405

    1:2000 A1 6 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC13 TO PC16

    SCALE 1:2000

    PLAN CANTERBURY PC13 TO PC16

    SCALE 1:2000

    ETW ROS SS

  • 5400 5500 5600 5700 5800 5900 6000 6100 6200 6300 6400 6500

    -100

    0

    100

    -100

    100

    Ro

    ad

    (B

    re

    dla

    nd

    s L

    an

    e)

    Existin

    g L

    V L

    in

    e

    Dra

    in

    Rive

    r

    Tra

    ck

    PC16

    PC17

    PC18

    PC19

    PC16

    PC17PC18 PC19

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 7 OF 21

    PLAN AND PROFILE DRAWINGS

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 7 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0406

    1:2000 A1 7 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC16 TO PC19

    SCALE 1:2000

    PLAN CANTERBURY PC16 TO PC19

    SCALE 1:2000

    ETW ROS SS

  • 6600 6700 6800 6900 7000 7100 7200 7300 7400 7500 7600

    -100

    0

    100

    -100

    100

    Rive

    r

    Pu

    blic R

    ig

    ht o

    f w

    ay

    Pu

    blic R

    ig

    ht o

    f w

    ay

    Tra

    ck

    PC19

    PC20

    PC21

    PC22

    PC19

    PC20

    PC21 PC22

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 8 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 8 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0407

    1:2000 A1 8 of 21 S.56

    B 01/12/2015 S.56 Application

    ETW

    PROFILE CANTERBURY PC19 TO PC22

    SCALE 1:2000

    PLAN CANTERBURY PC19 TO PC22

    SCALE 1:2000

    ROS SS

  • 7600 7700 7800 7900 8000 8100 8200 8300 8400 8500 8600 8700 8800

    -100

    0

    100

    -100

    100

    Dra

    in

    Tra

    ck

    Po

    nd

    Dra

    in

    Dra

    in

    Pu

    blic R

    ig

    ht o

    f w

    ay

    Dra

    in

    Tra

    ck

    Wa

    ll

    Pu

    blic R

    ig

    ht o

    f W

    ay

    Brid

    ge

    Tra

    ck

    Rive

    r - N

    eth

    erg

    on

    g P

    en

    n

    Dra

    in

    Dra

    in

    PC22

    PC23

    PC24

    PC25

    PC22 PC23

    PC24

    PC25

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 9 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 9 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0408

    1:2000 A1 9 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC22 TO PC25

    SCALE 1:2000

    PLAN CANTERBURY PC22 TO PC25

    SCALE 1:2000

    ETW ROS SS

  • 8800 8900 9000 9100 9200 9300 9400 9500 9600 9700 9800

    -100

    0

    100

    -100

    100

    Dra

    in

    Dra

    in

    Ro

    ad

    (S

    an

    dp

    it H

    ill)

    Dra

    in

    Up

    stre

    et W

    S

    ew

    ag

    e P

    ip

    e

    (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Existin

    g L

    V L

    in

    e

    Dra

    in

    Dra

    in

    PC25 PC26

    PC27

    PC28

    PC25 PC26 PC27

    PC28

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 10 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 10 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0409

    1:2000 A1 10 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC25 TO PC28

    SCALE 1:2000

    PLAN CANTERBURY PC25 TO PC28

    SCALE 1:2000

    ETW ROS SS

  • 9900 10000 10100 10200 10300 10400 10500 10600 10700 10800

    -100

    0

    100

    -100

    100

    Dra

    in

    Rive

    r (S

    arre

    P

    en

    )

    Pu

    blic F

    oo

    tp

    ath

    Dra

    in

    Tra

    ck

    Dra

    in

    Dra

    in

    PC28

    PC29 PC30

    PC31

    PC28

    PC29 PC30 PC31

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 11 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 11 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-410

    1:2000 A1 11 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC28 TO PC31

    SCALE 1:2000

    PLAN CANTERBURY PC28 TO PC31

    SCALE 1:2000

    ETW ROS SS

  • 10900 11000 11100 11200 11300 11400 11500 11600 11700 11800

    -100

    0

    100

    -100

    100

    Dra

    in

    Dra

    in

    Dra

    in

    Existin

    g L

    V L

    in

    e

    Dra

    in

    Rive

    r (S

    eve

    nsco

    re

    D

    ike

    )

    Fo

    otb

    rid

    ge

    Dra

    in

    Dra

    in

    PC31 PC32

    PC33

    PC34

    PC31 PC32

    PC33

    PC34

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 12 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 12 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0411

    1:2000 A1 12 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC31 TO PC34

    SCALE 1:2000

    PLAN CANTERBURY PC31 TO PC34

    SCALE 1:2000

    ETW ROS SS

  • 11900 12000 12100 12200 12300 12400 12500 12600 12700 12800 12900

    -100

    0

    100

    -100

    100

    Existin

    g 1

    32

    kV

    (P

    X)

    Ove

    rh

    ea

    d lin

    e

    (to

    b

    e te

    mp

    ora

    rily

    dive

    rte

    d)

    Existin

    g L

    V L

    in

    e

    SW

    W

    ate

    r P

    ip

    e (E

    xa

    ct

    po

    sitio

    n T

    BD

    )

    Dra

    in

    Ro

    ad

    A

    28

    (Isla

    nd

    R

    oa

    d)

    Dra

    in

    Dra

    in

    LH

    P G

    as P

    ip

    e (E

    xa

    ct

    po

    sitio

    n T

    BD

    )

    Dra

    in

    Ra

    ilw

    ay

    Dra

    in

    Dra

    in

    Dra

    in

    Dra

    in

    PC34 PC35

    PC36 PC37

    PC34 PC35 PC36 PC37

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 13 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 13 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0412

    1:2000 A1 13 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC34 TO PC37

    SCALE 1:2000

    PLAN CANTERBURY PC34 TO PC37

    SCALE 1:2000

    ETW ROS SS

  • 12900 13000 13100 13200 13300 13400 13500 13600 13700 13800 13900

    -100

    0

    100

    -100

    100

    Tra

    ck

    Rive

    r W

    an

    tsu

    m

    Dra

    in

    Dra

    in

    Dra

    in

    Dra

    in

    Dra

    in

    Dra

    in

    PC37

    PC38 PC39

    PC40

    North

    PC37 PC38 PC39 PC40

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 14 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 14 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0413

    1:2000 A1 14 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC37 TO PC40

    SCALE 1:2000

    PLAN CANTERBURY PC37 TO PC40

    SCALE 1:2000

    ETW ROS SS

  • 14000 14100 14200 14300 14400 14500 14600 14700 14800 14900 15000

    -100

    0

    100

    -100

    100

    SW

    W

    ate

    r p

    ip

    e

    (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Ro

    ad

    (G

    ore

    S

    tre

    et)

    MP

    G

    as P

    ip

    elin

    e

    (E

    xa

    ct p

    ositio

    n T

    BD

    )

    Pa

    th

    / P

    ub

    lic R

    ig

    ht o

    f w

    ay

    Dra

    in

    HP

    G

    as P

    ip

    elin

    e

    (E

    xa

    ct p

    ositio

    ns T

    BD

    )

    Dra

    in

    Dra

    in

    Dra

    in

    We

    ste

    rn

    M

    on

    kto

    n

    Stre

    am

    (D

    ra

    in

    )

    PX

    1

    32

    kV

    R

    ou

    te

    - T

    o b

    e

    te

    mp

    ora

    rily d

    ive

    rte

    d

    PC40

    PC41

    PC42

    PC43

    PC40 PC41 PC42 PC43

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 15 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 15 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0414

    1:2000 A1 15 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC40 TO PC43

    SCALE 1:2000

    PLAN CANTERBURY PC40 TO PC43

    SCALE 1:2000

    ETW ROS SS

  • 15100 15200 15300 15400 15500 15600 15700 15800 15900 16000

    -100

    0

    100

    -100

    100

    PY

    1

    32

    kV

    R

    ou

    te

    - T

    o b

    e

    te

    mp

    ora

    rily d

    ive

    rte

    d

    Pu

    blic R

    ig

    ht o

    f W

    ay

    Dra

    in

    Dra

    in

    Dra

    in

    Dra

    in

    SW

    W

    ate

    r p

    ip

    e

    (E

    xa

    ct p

    ositio

    n T

    BD

    )

    PC43

    PC44

    PC45

    PC46

    PC43

    PC44

    PC45 PC46

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 16 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 16 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0415

    1:2000 A1 16 of 21 S.56

    B 01/12/2015 S.56 Application

    ETW

    PROFILE CANTERBURY PC43 TO PC46

    SCALE 1:2000

    PLAN CANTERBURY PC43 TO PC46

    SCALE 1:2000

    SSROS

  • 16100 16200 16300 16400 16500 16600 16700 16800 16900 17000 17100

    -100

    0

    100

    -100

    100

    Tra

    ck

    Min

    ste

    r S

    tre

    am

    (D

    ra

    in

    )

    Dra

    in

    Dra

    in

    Dra

    in

    Min

    ste

    r M

    arsh

    es

    Dra

    in

    Dra

    in

    Pu

    blic R

    ig

    ht o

    f W

    ay

    PC46

    PC47

    PC48

    PC49

    PC46 PC47 PC48 PC49

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 17 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 17 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0416

    1:2000 A1 17 of 21 S.56

    B 01/12/2015 S.56 Application

    ETW

    PROFILE CANTERBURY PC46 TO PC49

    SCALE 1:2000

    PLAN CANTERBURY PC46 TO PC49

    SCALE 1:2000

    ROS

    SS

  • 17200 17300 17400 17500 17600 17700 17800 17900 18000 18100 18200

    -100

    0

    100

    -100

    100

    Dra

    in

    Dra

    in

    Tra

    ck (A

    bb

    ots W

    all)

    Min

    ste

    r M

    arsh

    es

    Dra

    in

    Re

    stricte

    d B

    yw

    ay

    (M

    arsh

    F

    arm

    R

    oa

    d)

    Dra

    in

    Existin

    g L

    V L

    in

    e

    Pu

    blic R

    ig

    ht o

    f W

    ay

    Rive

    r S

    to

    ur

    Pu

    blic R

    ig

    ht o

    f W

    ay

    PC49

    PC50

    PC51

    PC52

    PC49 PC50 PC51 PC52

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 18 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 18 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0417

    1:2000 A1 18 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC49 TO PC52

    SCALE 1:2000

    PLAN CANTERBURY PC49 TO PC52

    SCALE 1:2000

    ETW ROS SS

  • 18300 18400 18500 18600 18700 18800 18900 19000 19100 19200 19300

    -100

    0

    100

    -100

    100

    Dra

    in

    Dra

    in

    Dra

    in

    Existin

    g L

    V L

    in

    e

    Dra

    in

    Dra

    in

    Dra

    in

    PC52

    PC53

    PC54 PC55

    PC52 PC53 PC54 PC55

    0mOD

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 19 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 19 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0418

    1:2000 A1 19 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC52 TO PC55

    SCALE 1:2000

    PLAN CANTERBURY PC52 TO PC55

    SCALE 1:2000

    ETW ROS SS

  • 19400 19500 19600 19700 19800 19900 20000 20100 20200 20300 20400 20500 20600

    -100

    0

    100

    Dra

    in

    Tra

    ck

    Dra

    in

    Dra

    in

    SW

    W

    ate

    r P

    ip

    elin

    e (E

    xa

    ct

    po

    sitio

    n T

    BD

    )

    Dra

    in

    Dra

    in

    Dra

    in

    Ra

    ilw

    ay

    Dra

    in

    Dra

    in

    Wa

    ll

    Dra

    in

    Tra

    ck

    PC55 PC56

    PC57 PC58

    PC59

    PC60

    PC55 PC56

    PC57

    PC58

    PC59

    PC

    60

    Richborough PC Gantry

    -100

    100

    Pu

    blic R

    ig

    ht o

    f W

    ay

    SW

    W

    ate

    r P

    ip

    e (E

    xa

    ct

    po

    sitio

    n T

    BD

    )

    Rive

    r S

    to

    ur

    Richborough

    PC Gantry

    0mOD

    20700

    Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    REPRODUCED FROM ORDNANCE SURVEY MAPS.

    BY PERMISSION OF THE ORDNANCE SURVEY ON

    BEHALF OF THE CONTROLLER HER MAJESTY'S

    ORDNANCE SURVEY. OS LICENCE NO. 100024241

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 20 OF 21

    PLAN AND PROFILE DRAWING

    1. All dimensions are in metres.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    3. Plan and profiles show proposed 400kV pylon

    locations and heights and are subject to change.

    4. Proposed profiles based on statutory clearances and

    estimates of future maintenance scaffolding.

    5. Trees and vegetation are not shown for clarity.

    Canterbury - Richborough Circuit 1

    Canterbury - Richborough Circuit 2

    Earthwire - 160mm Optical Ground Wire

    8.1m Ground Clearance Line

    Ground Line

    Notes

    Key

    This drawing is scaled at paper size A1, therefore any

    prints taken at smaller sizes will affect accuracy of the

    measurement units and should not be scaled against.

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 20 OF 21

    PLAN AND PROFILE DRAWING

    A 16/12/2014 S.42 Consultation ETW ROSSS

    EN020017

    PDD-21497-2-OHL-0419

    1:2000 A1 20 of 21 S.56

    B 01/12/2015 S.56 Application

    PROFILE CANTERBURY PC55 TO PC60

    SCALE 1:2000

    PLAN CANTERBURY PC55 TO PC60

    SCALE 1:2000

    ETW ROS SS

  • Date Remarks Checked ApprovedDrawn

    COPYRIGHT NOT TO BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF THE NATIONAL GRID ELECTRICITY TRANSMISSION PLC

    Scale: Sheet size: Sheet: Status:

    National Grid Drawing Ref:

    Application Number:

    Version history:

    Version

    NATIONAL GRID (RICHBOROUGH

    CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS REGULATION 5(2)(o)

    AND TEN-E REGULATION EU347/2013

    SHEET 21 OF 21

    STAKING TABLE

    1. Height of PC8 ad PC9 have been determined using

    existing ground levels from NG supplied survey data.

    2. All dimensions are indicative and may change

    subject to article 5 (Limits of Deviation) of the DCO

    (Volume 2, Document 2.1).

    Notes

    NATIONAL GRID (RICHBOROUGH CONNECTION PROJECT) ORDER

    DESIGN DRAWINGS

    REGULATION 5(2)(o) AND TEN-E REGULATION EU347/2013

    SHEET 21 OF 21

    STAKING TABLE

    EN020017

    PDD-21497-2-OHL-0421

    N/A A1 21 of 21 S.56

    S.56 Application

    A 01/12/2015

    GJB ROS SS

  • Contact us

    Call our Freephone number: 0800 157 7878

    Visit our project website:www.richboroughconnection.co.uk

    Send an email to: [email protected]

    Follow us on Twitter: @NGRichborough

    Write to our freepost address at: FREEPOST RICHBCONNECTION

    PDD-21497-2-OHL-0058-PDD-21497-2-OHL-0058PDD-21497-2-OHL-0051-OHL-0051PDD-21497-2-OHL-0401-PDD-21497-2-OHL-0401PDD-21497-2-OHL-0402-PDD-21497-2-OHL-0402PDD-21497-2-OHL-0403-PDD-21497-2-OHL-0403PDD-21497-2-OHL-0404-PDD-21497-2-OHL-0404PDD-21497-2-OHL-0405-PDD-21497-2-OHL-0405PDD-21497-2-OHL-0406-PDD-21497-2-OHL-0406PDD-21497-2-OHL-0407-PDD-21497-2-OHL-0407PDD-21497-2-OHL-0408-PDD-21497-2-OHL-0408PDD-21497-2-OHL-0409-PDD-21497-2-OHL-0409PDD-21497-2-OHL-0410-PDD-21497-2-OHL-0410PDD-21497-2-OHL-0411-PDD-21497-2-OHL-0411PDD-21497-2-OHL-0412-PDD-21497-2-OHL-0412PDD-21497-2-OHL-0413-PDD-21497-2-OHL-0413PDD-21497-2-OHL-0414-PDD-21497-2-OHL-0414PDD-21497-2-OHL-0415-PDD-21497-2-OHL-0415PDD-21497-2-OHL-0416-PDD-21497-2-OHL-0416PDD-21497-2-OHL-0417-PDD-21497-2-OHL-0417PDD-21497-2-OHL-0418-PDD-21497-2-OHL-0418PDD-21497-2-OHL-0419-PDD-21497-2-OHL-0419PDD-21497-2-OHL-0421-PDD-21497-2-OHL-0421