Design and Practical Implementation of Advanced Reconfigurable Digital Controllers for Low-Power
Multi-Phase DC-DC Converters
by
Zdravko Lukic
A thesis submitted in conformity with the requirements for the degree of Doctor of Philosophy
Graduate Department of Electrical and Computer Engineering University of Toronto
© Copyright by Zdravko Lukic 2011
ii
Design and Practical Implementation of Advanced Reconfigurable Digital
Controllers for Low-Power Multi-Phase DC-DC Converters
Zdravko Lukic
Doctor of Philosophy
Graduate Department of Electrical and Computer Engineering University of Toronto
2011
Abstract
The main goal of this thesis is to develop practical digital controller architectures for multi-phase
dc-dc converters utilized in low power (up to few hundred watts) and cost-sensitive applications.
The proposed controllers are suitable for on-chip integration while being capable of providing
advanced features, such as dynamic efficiency optimization, inductor current estimation,
converter component identification, as well as combined dynamic current sharing and fast
transient response.
The first part of this thesis addresses challenges related to the practical implementation of
digital controllers for low-power multi-phase dc-dc converters. As a possible solution, a multi-
use high-frequency digital PWM controller IC that can regulate up to four switching converters
(either interleaved or standalone) is presented. Due to its configurability, low current
consumption (90.25 μA/MHz per phase), fault-tolerant work, and ability to operate at high
switching frequencies (programmable, up to 10 MHz), the IC is suitable to control various dc-dc
converters. The applications range from dc-dc converters used in miniature battery-powered
electronic devices consuming a fraction of watt to multi-phase dedicated supplies for
communication systems, consuming hundreds of watts.
iii
A controller for multi-phase converters with unequal current sharing is introduced and an
efficiency optimization method based on logarithmic current sharing is proposed in the second
part. By forcing converters to operate at their peak efficiencies and dynamically adjusting the
number of active converter phases based on the output load current, a significant improvement in
efficiency over the full range of operation is obtained (up to 25%). The stability and inductor
current transition problems related to this mode of operation are also resolved.
At last, two reconfigurable digital controller architectures with multi-parameter estimation are
introduced. Both controllers eliminate the need for external analog current/temperature sensing
circuits by accurately estimating phase inductor currents and identifying critical phase
parameters such as equivalent resistances, inductances and output capacitance. A sensorless non-
linear, average current-mode controller is introduced to provide fast transient response (under 5
μs), small voltage deviation and dynamic current sharing with multi-phase converters. To
equalize the thermal stress of phase components, a conduction loss-based current sharing scheme
is proposed and implemented.
iv
Acknowledgments I wish to thank my supervisor, Professor Aleksandar Prodić, for his great support during my
doctoral studies. Professor Prodić’s dedication, scientific vision, and research passion have
served as inspiration and motivation for me to achieve more and perform better than I could have
ever imagined. I am also thankful for his valuable advices that often extended beyond my thesis
work. Professor Prodić was always able to give me honest constructive feedback that helped me
to improve. His wisdom will stay with me, following me in my future career path.
During my doctoral studies, I had the great honor and pleasure to work with my dear
colleagues and friends: Zhenyu Zhao (‘Frank’), Amir Parayandeh, S M Ahsanuzzaman, Andrija
Stupar, Aleksandar Radić, Jason Weinstein, Massimo Tarulli, and Jurgen Alico. We always
acted as a terrific team and helped each other to succeed. I will always remember those mission-
impossible chip tape-outs with Amir, Aleksandar, and Jason, and conference paper deadlines
with Ahsan and Frank.
I would like to also thank our industry partners Lee Clevelend, Dimitry Goder, and Rob de
Nie for sharing with us their faith and excitement for digitally-controlled SMPS. It was a
remarkable experience to work and learn from these leading industry professionals. I am grateful
for their invaluable support to our group during numerous research projects.
I would like to mention family Milenov from Toronto and family Huerta-Calva from Celaya,
Mexico. They shared the warmth of their home with me. I thank them for their generous help and
for all those unforgettable moments that always kept me positive even through hard times.
I am deeply thankful to my mother Slavica, father Rajko, and sister Milijana for their support
and understanding of my passion for scientific work. The hard work of my parents and
persistence always inspired me to be a better student.
Finally, I would like to dedicate this thesis to my wife Santa Concepción Huerta Olivares. I
thank her for unlimited understanding, profound love, and all the sacrifices she made during our
doctoral studies. I am thrilled about our joined future. Forever and ever!
v
Table of Contents Acknowledgments .......................................................................................................................... iv
Table of Contents ............................................................................................................................. v
List of Tables .................................................................................................................................. ix
List of Figures .................................................................................................................................. x
List of Appendices ........................................................................................................................ xiv
Chapter 1 − Introduction .............................................................................................................. 1
1.1 Design Requirements for Modern Power Management Systems in Low-Power Applications ......................................................................................................................... 1
1.2 Multi-Phase Digital Controller Design Challenges ............................................................. 3
1.3 Thesis Objectives and Organization .................................................................................... 4
References ............................................................................................................................ 5
Chapter 2 – Multi-Use and Fault-Tolerant Digital Controller IC ............................................ 9
2.1 Introduction .......................................................................................................................... 9
2.2 System Operation and Controller Architecture ................................................................. 11
2.3 Multi-Phase Digital Pulse-Width Modulator ..................................................................... 11
2.3.1 Operation with 3 Phases and Number Conversion Logic ...................................... 13
2.3.2 Dual-Biased Delay Cell for Wide-Frequency Range ............................................ 14
2.3.3 Segmented Bias Circuit ......................................................................................... 16
2.3.4 Digital Delay-Lock Logic ...................................................................................... 18
2.4 Programmable Dead-Time Circuit .................................................................................... 19
2.5 ADC Implementation ......................................................................................................... 19
2.6 IC Implementation ............................................................................................................. 20
2.7 Experimental Results ......................................................................................................... 21
2.7.1 Open Loop Tests .................................................................................................... 21
vi
2.7.2 Closed Loop Tests ................................................................................................. 22
2.7.3 Fault-Tolerant Operation ....................................................................................... 23
2.8 Conclusion ......................................................................................................................... 24
References .......................................................................................................................... 24
Chapter 3 − Dynamic Efficiency Optimization for Multi-Phase Converters ......................... 29
3.1 Introduction ........................................................................................................................ 29
3.2 System Architecture ........................................................................................................... 31
3.3 Practical Implementation ................................................................................................... 32
3.3.1 Accurate Current Regulation ................................................................................. 33
3.3.2 Jitter Elimination.................................................................................................... 34
3.4 Transient Operation ........................................................................................................... 35
3.5 Design of Converter Phases ............................................................................................... 38
3.6 Experimental System and Results ..................................................................................... 40
3.6.1 Steady-State Operation .......................................................................................... 40
3.6.2 Transient Operation ............................................................................................... 41
3.6.3 Measured Converter Efficiency ............................................................................. 42
3.7 Conclusion ......................................................................................................................... 43
References .......................................................................................................................... 43
Chapter 4 − Reconfigurable Digital Controllers with Multi-Parameter Estimation ............ 46
4.1 Introduction ........................................................................................................................ 46
4.2 Principle of Current-Estimator Operation ......................................................................... 49
4.3 Practical Implementation of the Current Estimator ........................................................... 51
4.3.1 Filter Architecture and Self-Calibration ................................................................ 52
4.3.1.1 Filter Gain Calibration Procedure ........................................................... 53
4.3.1.2 Filter Time Constant Calibration Procedure ........................................... 55
4.3.1.3 Offset Calibration Procedure ................................................................... 57
vii
4.3.2 Steady-State Current Estimator Architecture ........................................................ 58
4.4 Principle of Temperature Monitoring Operation ............................................................... 59
4.5 Inductor and Output Capacitor Identification .................................................................... 60
4.5.1 Inductor Identification ........................................................................................... 61
4.5.2 Output Capacitor Identification ............................................................................. 61
4.6 Oversampled Non-Linear Average Current-Mode Controller for Multi-Phase Converters .......................................................................................................................... 62
4.6.1 Steady-State Mode ................................................................................................. 62
4.6.2 Multi-Phase Current Estimator Tuning and Phase Identification .......................... 63
4.6.3 Conduction Loss-Based Current Sharing Scheme ................................................. 64
4.6.4 Transient Mode ...................................................................................................... 66
4.6.5 Hardware Optimization and Controller On-Chip Complexity .............................. 69
4.7 Experimental Systems and Results .................................................................................... 70
4.7.1 Filter Gain Calibration ........................................................................................... 71
4.7.2 Filter Time Constant Calibration ........................................................................... 72
4.7.3 Offset Calibration .................................................................................................. 74
4.7.4 Calibrated Operation .............................................................................................. 74
4.7.5 Current Estimation with the Steady-State Current Estimator ................................ 75
4.7.6 Temperature Monitoring and Protection ............................................................... 76
4.7.7 Overload Protection ............................................................................................... 76
4.7.8 Multi-Phase Operation with the Non-Linear Average Current-Mode Controller ............................................................................................................... 77
4.7.9 Accuracy of Current and Temperature Estimation ................................................ 80
4.8 Conclusion ......................................................................................................................... 81
References .......................................................................................................................... 81
viii
Chapter 5 − Conclusions and Future Work .............................................................................. 87
5.1 Thesis Contributions .......................................................................................................... 87
5.2 Future Work ....................................................................................................................... 89
Appendix A − Filter Time Constant Calculation ...................................................................... 90
Appendix B − Quantization Error Effects on Current Estimator Accuracy ......................... 92
ix
List of Tables Table 2.1: Summary of the IC parameters. .................................................................................... 20
Table 3.1: Important parameters of the 4-phase logarithmic buck converter……………………40
Table 4.1: The silicon area and gate count of the multi-phase controller when implemented in
TSMC 0.18-µm CMOS process………………………………………………………………….70
Table B.1: Current estimator relative error versus quantization step of the output
voltage ADC…….……………………….………………………………………………………92
x
List of Figures Figure 1.1: Block diagram of a power management system implemented in notebooks (source:
Texas Instruments). .......................................................................................................................... 1
Figure 2.1: A block diagram of the multi-use and fault-tolerant digital controller IC regulating
operation of a 4 phase interleaved buck converter. ....................................................................... 10
Figure 2.2: A block diagram of the proposed multi-phase digital pulse-width modulator............ 12
Figure 2.3: Phase synchronization: a) start signals during 4-phase interleaved operation; b) 3-
phase interleaved operation. .......................................................................................................... 12
Figure 2.4: The 3-phase MDPWM operation: a) the absolute duty cycle error vs. 8-bit duty ratio
command dc[n]; b) actual duty cycle versus dc[n]. ........................................................................ 14
Figure 2.5: A delay cell with adjustable propagation time tpd: a) conventional current-starved
delay cell b) proposed dual-biased current-starved delay cell. ...................................................... 15
Figure 2.6: Proposed adjustment of the current-starved delay cell current im(t) in the delay line
versus the desired switching frequency fsw. ................................................................................... 16
Figure 2.7: Digitally controlled segmented-bias circuit. ............................................................... 17
Figure 2.8: a) A block diagram of digital delay-locking logic; b) MDPWM delay line signals
when 1, 2, or 4 phases are active. .................................................................................................. 18
Figure 2.9: Programmable dead-time circuit. ................................................................................ 19
Figure 2.10: a) Fabricated chip die of the multi-use digital controller IC b) Current consumption
breakdown. ..................................................................................................................................... 20
Figure 2.11: MDPWM linearity test at 100 kHz – Ch1: output converter voltage (1 V/div). ....... 21
Figure 2.12: MDPWM operation at 10 MHz: a) the duty ratio command is changed between 4
consecutive values b) linearly distributed falling edges of the pulse-width modulated signals (8-
bit resolution at 10 MHz). .............................................................................................................. 22
xi
Figure 2.13: Closed-loop operation of the controller IC: a) four 1-MHz buck converters are
regulated to produce four supply rails between 1.2 and 3.3 V; b) transient response of the
controller when the voltage reference is dynamically changed; c) two-phase interleaved steady-
state operation; d) four-phase interleaved steady-state operation; ................................................ 23
Figure 2.14: Fault-tolerant operation in the closed loop. ............................................................... 24
Figure 3.1: Block diagram of a digitally controlled multi-phase converter with logarithmic
current sharing. .............................................................................................................................. 30
Figure 3.2: Detailed system architecture of the proposed controller with a logarithmic current
sharing. ........................................................................................................................................... 31
Figure 3.3: The output voltage regulation is affected by the jitter (shown in the red circle) of
itot[n]. .............................................................................................................................................. 34
Figure 3.4: Operation of the hysteretic logic – output phase enable signal versus input control
value itot[n]. .................................................................................................................................... 35
Figure 3.5: The effect of finite rising Δ1 and falling current slope Δ2 on itot(t) for a step of the
digital current command itot[n] from 5.4Inom A to 3.6Inom. ............................................................. 36
Figure 3.6: Simulated transient operation of the controller during a heavy-to-light load transient
between 5.4Inom and 3.6Inom. .......................................................................................................... 38
Figure 3.7: a) Simulated efficiency characteristics of the converter phases operating at different
switching frequencies b) Simulated efficiency of the whole system. ........................................... 39
Figure 3.8: Steady-state operation with two different load currents: a) 39 A b) 12 A. ................. 40
Figure 3.9: Transient response for a load step from 21 A to 19 A when the phase enable corrector
and transient current estimator are: a) disabled b) enabled. .......................................................... 41
Figure 3.10: Transient response: a) from 9 A to 38 A; b) from 38 A to 9 A. ............................... 42
Figure 3.11: Measured efficiency characteristics of the converter based on: a) logarithmic current
sharing and uniform current sharing b) logarithmic current sharing and phase shadowing. ......... 43
xii
Figure 4.1: a) A digitally-controlled buck converter with the self-tuning current estimator and
remote temperature monitoring system b) A dual-phase buck converter regulated by the non-
linear multi-phase digital average current-mode controller based on the multi-phase self-tuning
current estimator. ........................................................................................................................... 47
Figure 4.2: Current sensing techniques: a) conventional analog implementation b)
implementation with a self-tuning digital filter. ............................................................................ 49
Figure 4.3: Test current sink circuit used for the filter calibration. ............................................... 51
Figure 4.4: Signals of a filter implemented with an over-sampling ADC. .................................... 52
Figure 4.5: The architecture of the tunable IIR filter used in the current estimator. ..................... 53
Figure 4.6: Filter gain calibration procedure: simulated response of the current estimator during
output load change for two cases (bottom curve) the initial value of RL is twice the actual value
(top curve) after the filter adjustment. ........................................................................................... 54
Figure 4.7: The buck converter (a) and its steady-state dc equivalent circuit Req (b) used for
current estimation. ......................................................................................................................... 55
Figure 4.8: Calibration of the time constant: simulated response of the current estimator during
output load change between 2 A and 2.5A; (bottom) for τf=0.5τL; (top) for τf=τL. ....................... 56
Figure 4.9: Offset in the estimated current isense[n] caused by the operation of the dead-time
circuit and converter. ..................................................................................................................... 57
Figure 4.10: The implementation of the steady-state current estimator. ....................................... 59
Figure 4.11: Change of RL_calibrated due to the ambient temperature for different output load
current conditions. ......................................................................................................................... 60
Figure 4.12: Differential output capacitor and phase inductance identification. ........................... 64
Figure 4.13: Mismatch in phase equivalent resistances generates unequal thermal stress on power
switches. ......................................................................................................................................... 65
xiii
Figure 4.14: Transient mode operation of the non-linear average current-mode controller. ........ 68
Figure 4.15: A time-multiplexed N-phase digital current estimator. ............................................. 70
Figure 4.16: System operation. ..................................................................................................... 71
Figure 4.17: The filter gain (1/RL_calibrated) calibration procedure. ................................................. 72
Figure 4.18: The filter time calibration procedure: a) τf=0.5τL ; b) τf ≈ τL. ................................... 73
Figure 4.19: The filter offset calibration procedure ....................................................................... 74
Figure 4.20: The estimated current during load steps between 1.5 A and 4.5 A. .......................... 75
Figure 4.21: The estimated current with a steady-state current estimator during the load step
between 0.8 A and 5.1 A................................................................................................................ 75
Figure 4.22: Thermal monitoring: a) at 45 °C; b) at 105°C. ......................................................... 76
Figure 4.23: Overload protection implemented with the current estimator................................... 77
Figure 4.24: Current estimator tuning and component identification with the multi-phase
converter. ....................................................................................................................................... 78
Figure 4.25: Transient response of the nonlinear average current-mode controller. ..................... 79
Figure 4.26: The effectivness of the conduction-loss based current sharing scheme. ................... 79
Figure 4.27: a) Estimated inductor current versus the output load current with a 1 A sink step
size b) Relative error of the estimated current for two sink step sizes: 1 A and 2 A..................... 80
Figure 4.28: Estimated temperature versus sensor temperature. ................................................... 81
xiv
List of Appendices Appendix A – Filter Time Constant Calculation………………………………………………...90
Appendix B – Quantization Error Effects on Current Estimator Accuracy……………………..92
1
Chapter 1 Introduction
This thesis presents the design and practical implementation of advanced digital controllers for
multi-phase dc-dc converters utilized in low-power applications such as consumer electronics,
computer servers, and telecommunication equipment. In the following sections, common design
requirements in such applications are examined, multi-phase controller design challenges are
identified, and thesis objectives are formulated accordingly.
1.1 Design Requirements for Modern Power Management
Systems in Low-Power Applications
Figure 1.1 shows a complex power management system found in a typical notebook computer.
The power is delivered to internal devices (i.e. processor, graphic card, and memory) by several
high-efficiency, power processing units (PPU). All PPUs are connected to a shared dc-bus
voltage generated from either a lithium-ion battery source or an ac adapter. The PPUs usually
employ multi-phase switching converters regulated by a dedicated controller circuit.
Figure 1.1: Block diagram of a power management system implemented in notebooks (source: Texas Instruments).
CHAPTER 1. INTRODUCTION 2
The multi-phase converters, shown in Fig. 1.1, utilize between two and four dc-dc converter
phases connected in parallel. The primary role of these phases is to step down the dc-bus voltage,
usually between 0.5 V and 3.3 V, and supply and share the output load current. The number of
parallel converter phases depends on the current consumption ratings of the specific load device.
The common design requirements for the controller circuit and multi-phase converters, used
in power management systems for low-power applications (up to 100 W), are:
• small size of required components due the small form factor of electronic devices,
• minimized component count and reduced cost obtained through on-chip integration of
controller circuitry and regulation of a larger number of converter phases with a single
controller integrated circuit,
• high efficiency of the converter and low power consumption of the controller circuitry
required to reduce amount of generated heat, improve the battery life, and energy
efficiency ratings of the device,
• fast transient response required to minimize the size of energy storage components and
provide reliable operation of supplied devices during load current transients,
• over-current and over-temperature protection of the converter components and load
devices,
• proper current sharing between paralleled converters to avoid unequal stress of converter
components, provide equal aging of all converters, and uniform heat distribution.
Digital controllers [1]-[23] that are capable of satisfying some of these stringent requirements
have emerged just recently. To reduce the size of converter components, they usually operate at
high switching frequencies [2]-[5], while having small power consumption and low hardware
complexity suitable for on-chip integration. More advanced digital controllers are also able to
achieve fast transient response [6]-[9] limited by the converter components, identify single-phase
converter parameters, self-compensate [10]-[13], and optimize the efficiency of single-phase
converters by adjusting the size of switching devices [4], [14] and changing modes of the
controller operation [3], [15].
CHAPTER 1. INTRODUCTION 3
Previous controller designs were mainly focused on single-phase converters and practical
controller solutions for multi-phase converters are still missing. The multi-phase converters are
currently used in many applications that could greatly benefit with utilization of advanced
control and power management techniques from single-phase converters. However, applying
these techniques to multi-phase converters is not straightforward due mainly to various design
challenges and implementation problems that will be discussed in the following section.
1.2 Multi-Phase Digital Controller Design Challenges
The utilization of the state-of-the-art digital controller ICs [19], [21], [23] for multi-phase and
multiple standalone dc-dc converters, used in the systems similar to the one shown in Fig. 1.1, is
still restricted to high-end products such as computer servers and data communication
equipment. There are two primary reasons for this limitation: 1) high power consumption of
multi-phase digital controllers (several tens of milliwatts), and 2) higher development/production
costs. The power consumption makes the multi-phase digital controllers impractical for
utilization in battery-powered electronic devices, such as cellphones, ebook readers, and
computer tablets. There are also several major technical problems that remain unsolved.
The first problem is related to dynamic efficiency optimization of multi-phase converters used
in power management systems of Fig. 1.1. To improve efficiency, reduce generated heat, and
increase the battery life, digital controllers commonly utilize efficiency optimization schemes
[24]-[26] based on the phase shedding method. However, controller designs with such schemes
are quite challenging because the controlled plant dynamically changes every time the active
number of phases is adjusted. To avoid potential stability problems, conservative controller
designs that sacrifice transient response of the converter for improved efficiency are utilized in
practice.
The second major problem is associated with the current sensing for single-phase and multi-
phase converters and temperature monitoring. The current information is essential for over-
current protection [27], efficiency optimization [22], [26], [28], [29] and current sharing
purposes [30]-[36]. The converter inductor currents are still measured using analog circuitry
[37]. Implementation of external analog current sensing circuits and their integration with
integrated digital controllers is usually costly and difficult due to the requirement for multiple
CHAPTER 1. INTRODUCTION 4
analog-to-digital converters (ADCs).
The third problem is related to parameter estimation of multi-phase converters. Existing
identification methods [10]-[13] are designed to determine inductor-capacitor products of single-
phase converters. However, they cannot be directly applied to multi-phase converters where
multiple inductor branches are connected to a common output capacitor. If phase components
(i.e. phase inductances and output capacitor) could be identified separately, their values could be
used to improve the transient response of the converter.
Combined fast transient response and dynamic current sharing is also an important design
issue with multi-phase converters. Recent multi-phase digital controllers [38]-[40] provide
proper sharing of the load current between multiple converter phases but they suffer from the
limited controller bandwidth and slow converter response under large load steps.
1.3 Thesis Objectives and Organization In this thesis solutions for the above listed problems are presented. Mainly, new concepts are
introduced and tested on single phase systems, then adapted for multi-phase systems. In other
words, even designs for single-phase converters are implemented with the final goal of multi-
phase application in mind. The thesis goals and content of remaining chapters are briefly
summarized below.
A low-cost flexible multi-phase digital controller IC that can be easily configured and
employed in various applications will be developed in the first part of this thesis. The IC will
operate between 100 kHz and 10 MHz and it will exhibit low power consumption for use in
portable applications. The IC will be utilized for interleaved converters having between 2 and 4
converter phases and/or it will simultaneously regulate up to 4 standalone converters providing
different output voltages. All major controller parameters (i.e. switching frequency, number of
active phases, etc.) of the IC will be externally programmable in order to achieve optimum
performance for a specific application. The design, implementation and experimental operation
of the system will be presented in Chapter 2.
The problem of dynamic efficiency optimization for multi-phase converters will be addressed
and resolved in Chapter 3. This chapter will present a current-program mode digital controller
architecture and a multiphase dc-dc converter with non-uniform current sharing that dynamically
CHAPTER 1. INTRODUCTION 5
optimize converter efficiency over the full load range of operation.
Chapter 4 will introduce advanced reconfigurable digital controllers with multi-parameter
estimation for single-phase and multi-phase converters. They can accurately estimate inductor
currents, perform identification of key converter parameters, and provide remote temperature
monitoring of power switches. In the case of the multi-phase converters, the proposed sensorless
non-linear average current-mode controller will utilize the identified power stage parameters and
estimated inductor currents to provide fast transient response, while maintaining dynamic current
sharing and equalized thermal stress between converter phases.
Chapter 5 concludes this thesis and suggests potential new research directions with author’s
anticipation that presented technical solutions in this thesis will fuel development of digitally-
controlled multi-phase converters that are inexpensive, energy efficient, and environmentally
friendly.
REFERENCES
[1] A. Dancy, R. Amirtharajah, A. Chandrakasan, “High-efficiency multiple-output dc-dc
conversion for low-voltage systems,” IEEE Transactions on VLSI Systems, vol. 8, no. 3, pp. 252–263, 2000.
[2] B. Patella, A. Prodić, A. Zirger, D. Maksimović, ”High-frequency digital controller PWM
controller IC for DC-DC converters,” IEEE Trans. Power Electronics, Special Issue on Digital Control, vol. 18, pp. 438-446, Jan. 2003.
[3] J.Xiao, A.V. Peterchev, J. Zhang, S.R. Sanders, “A 4-μA quiescent-current dual-mode
digitally controlled buck converter IC for cellular phone applications,” IEEE Journal of Solid-State Circuits, vol. 39, pp. 2342–2348, Dec. 2004.
[4] O. Trescases, “Integrated power-supplies for portable applications,” Ph.D. thesis,
University of Toronto, 2007. [5] Z. Lukić, N. Rahman, A. Prodić, "Multi-bit sigma-delta PWM digital controller IC for DC-
DC converters operating at switching frequencies beyond 10 MHz," IEEE Transactions on Power Electronics, vol.22, pp. 1693-1707., Sept. 2007.
[6] G. Feng, E. Meyer, and Y.-F. Liu, “A new digital control algorithm to achieve optimal
dynamic performance in DC-to-DC converters,” IEEE Trans. Power Electron., vol. 22, pp. 1489–1498, July 2007.
[7] Zhenyu Zhao, A. Prodić, “Continuous-time digital controller for high-frequency DC-DC
converters,” IEEE Trans. Power Electron., vol. 23, pp. 564–573, Mar. 2008.
CHAPTER 1. INTRODUCTION 6
[8] L. Corradini, P. Mattavelli, E. Tedeschi, and D. Trevisan, “High-bandwidth multisampled
digitally controlled DCDC converters using ripple compensation,” IEEE Trans. Ind. Electron.,vol. 55, pp. 1501–1508, Apr. 2008.
[9] A. Babazadeh, D. Maksimović, “Hybrid digital adaptive control for fast transient response
in synchronous buck DC–DC converters,” IEEE Trans. Power Electron., vol. 24, pp. 2625 – 2638, Nov. 2009.
[10] Zhenyu Zhao, A. Prodić, “Limit-cycle oscillations based auto-tuning system for digitally
controlled DC-DC power supplies,” IEEE Trans. Power Electron., vol. 22, pp. 2211–2222, Nov. 2007.
[11] L. Corradini, P. Mattavelli, W. Stefanutti, S. Saggini, “Simplified model reference-based
autotuning for digitally controlled smps,” IEEE Trans. Power Electron., vol. 23, pp. 1956–1963, July 2008.
[12] J. Morroni, R. Zane, D. Maksimović, “Design and implementation of an adaptive tuning
system based on desired phase margin for digitally controlled DC-DC converters,” IEEE Trans. Power Electron., vol. 24, pp. 559–564, Feb. 2009.
[13] M. Shirazi, R. Zane, D. Maksimović, “An Autotuning digital controller for DC–DC power
converters based on online frequency-response measurement,” IEEE Trans. Power Electron., vol. 24, pp. 2578 - 2588, Nov. 2009.
[14] O. Trescases, Wai Tung Ng, H. Nishio, M. Edo, T. Kawashima, “A digitally controlled
DC-DC converter module with a segmented output stage for optimized efficiency,” in Proc. International Symposium on Power Semiconductor Devices and IC's, 2006, pp. 1 – 4.
[15] N. Rahman, A. Parayandeh, K. Wang, A.Prodić, “Multimode digital SMPS controller IC
for low-power management,” in Proc. IEEE International Symposium on Circuits and Systems, 2006, 2006, pp.35-40.
[16] A.V. Peterchev, J. Xiao, S.R. Sanders, “Architecture and implementation of a digital VRM
controller,” IEEE Transactions on Power Electronics, vol.18, issue 1, pp. 356 – 364, Jan. 2003.
[17] Xu Zhang, Yang Zhang, R. Zane, D. Maksimović, “Design and implementation of a wide-
bandwidth digitally controlled 16-phase converter,” in Proc. IEEE Workshops on, Computers in Power Electronics, 2006, pp.106-111.
[18] Z. Lukic, C. Blake, Santa C. Huerta, A. Prodić, “Universal and fault-tolerant multiphase
Digital PWM Controller IC for high-frequency DC-DC converters,” in Proc. IEEE Applied Power Electronics Conf., 2007, pp. 42–47.
[19] J. Zhang, S.R. Sanders, “A digital multi-mode multi-phase IC controller for voltage
regulator application,” in Proc. IEEE Applied Power Electronics Conf., 2007, pp. 719–726.
CHAPTER 1. INTRODUCTION 7
[20] Data Sheet, ZL2004, Step-down DC-DC controller with power management, Zilker Labs. [21] Data Sheet, UCD9240, Digital Power Point of Load System Controller, Texas Instruments
Inc. [22] Data Sheet, ZL2005, Step-down DC-DC controller with power management, Zilker Labs. [23] Data Sheet, UCD9220, Digital pwm system controller, Texas Instruments Inc. [24] P. Zumel, C. Fernandez, A. de Castro, O. Garcia, “Efficiency improvement in multiphase
converter by changing dynamically the number of phases,” in Proc. IEEE Power Electronics Specialists Conf., 2006, pp. 1-6.
[25] Jia Wei, F.C. Lee, “Two-stage voltage regulator for laptop computer CPUs and the
corresponding advanced control schemes to improve light-load performance,” in Proc. IEEE Applied Power Electronics Conf., 2004, pp. 1294 - 1300.
[26] J.A. Abu Qahoug, L. Huang, “Highly efficient VRM for wide load range with dynamic
non-uniform current sharing,” in Proc. IEEE Applied Power Electronics Conf., 2007, pp. 543 - 549.
[27] H. Peng, D. Maksimović, “Overload protection in digitally controlled DC-DC converters,"
in Proc. IEEE Power Electronics Specialist Conf., Jun. 2006, pp. 1 – 6. [28] Z. Lukić, Zhenyu Zhao, A. Prodić, D. Goder, “Digital controller for multi-phase DC-DC
converters with logarithmic current sharing,” in Proc. IEEE Power Electronics Specialist Conf., 2007, pp. 119 – 123.
[29] A. Parayandeh, Chu Pang, A. Prodić, “Digitally controlled low-power DC-DC converter
with instantaneous on-line efficiency optimization,” in Proc. IEEE Applied Power Electronics Conf., 2009, pp. 159- 163.
[30] B. Tomescu, H.F. Vanlandingham, “Improved large-signal performance of paralleled DC-DC converters current sharing,” IEEE Trans. Power Electron., vol. 14, pp. 573 – 577, May 1999.
[31] Peng Li, B. Lehman, “A design method for paralleling current mode controlled DC-DC converters,” IEEE Trans. Power Electron., vol. 19, pp. 748 – 756, May 2004.
[32] J. Abu-Qahouq, Mao Hong, I. Batarseh, “Multiphase voltage-mode hysteretic controlled DC-DC converter with novel current sharing,” IEEE Trans. Power Electron., vol. 19, pp. 1397 – 1407, Nov 2004.
[33] Jaber A. Abu Qahouq, Lilly Huang, Doug Huard and Allan Hallberg, “Novel current sharing schemes for multiphase converters with digital controller implementation,” in Proc. IEEE Applied Power Electronics Conf., Feb. 2007, pp. 148 – 156.
CHAPTER 1. INTRODUCTION 8
[34] Y. Zhang, R. Zane, D. Maksimović, “Current sharing in digitally controlled masterless multi-phase DC-DC Converters,” in Proc. IEEE Power Electronics Specialist Conf., Jun. 2005, pp. 2722 – 2728.
[35] Mao Hong, Liangbin Yao, Caisheng Wang, I. Batarseh, “Analysis of inductor current sharing in nonisolated and isolated multiphase DC-DC converters,” IEEE Trans. Power Electron., vol. 54, pp. 3379 – 3388, Dec 2007.
[36] V. Choudhary, E. Ledezma, R. Ayyanar, R.M. Button, “Fault tolerant circuit topology and control method for input-series and output-parallel modular DC-DC converters,” IEEE Trans. Power Electron., vol. 23, pp. 402 – 411, Jan 2008.
[37] H. Forghani-zadeh, G. Rincón-Mora, “Current sensing techniques for DC-DC converters,”
in Proc. IEEE MWSCAS, Aug. 2002, pp. 577– 580.
[38] Jaber A. Abu Qahouq, Lilly Huang, “N-phase sensor-less current sharing digital controller,” in Proc. IEEE Power Electronics Specialist Conf., 2008, pp. 1257 – 1262.
[39] A. Kelly, “Current Share in Multiphase DC–DC Converters Using Digital Filtering Techniques,” IEEE Trans. Power Electron., vol. 24, pp. 212 – 220, Jan 2009.
[40] Xu Zhang, L. Corradini, D. Maksimovic, “Sensorless current sharing in digitally controlled two-phase buck DC-DC converters,” in Proc. IEEE Applied Power Electronics Conf., 2009, pp. 70 – 76.
9
Chapter 2 Multi-Use and Fault-Tolerant Digital Controller IC
2.1 Introduction In multi-phase dc-dc converters, potential advantages of digital controllers over traditional
analog solutions are evident. Digital systems allow implementation of complex power
management techniques and advanced control laws [1]-[13]. It has also been shown that digital
controllers are able to closely match multiple pulse-width modulated signals [14], which is
important in implementing accurate current sharing [14,15].
Despite these advantages, there has been limited utilization of digital controllers in multi-
phase systems, largely due to unsolved practical implementation problems. Compared to analog
solutions [16,17], most existing digital architectures require significantly larger silicon area and
have a relatively high power consumption (usually in the range of tens of mW/MHz) [18,19],
both of which are making them impractical for on-chip implementation required in targeted high-
volume systems. High power consumption presents a very serious limitation in upcoming
converters, which are expected to switch much faster than the existing converters, in order to
reduce the size of energy storage components.
The main goal of this chapter is to introduce a versatile multi-phase digital controller IC
architecture, shown in Fig. 2.1, which has low power consumption and takes small silicon area,
comparable to that of analog systems. The new IC also exploits flexibility of digital
implementation. It can be set to operate as a controller for interleaved converters having 2 to 4
phases and/or simultaneously regulate up to 4 standalone converters providing different output
voltages. Furthermore, in multi-phase mode, this architecture features fault-tolerant operation
providing uninterrupted output voltage in the case of a failure in one of the phases.
The key block of the new IC is a reconfigurable multi-phase digital pulse-width modulator
(MDPWM). The programmable parameters are switching frequency (between 100 kHz and 10
MHz), phase shifts between PWM signals, as well as dead-times.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 10
In this IC, compensator coefficients and voltage references can be also dynamically adjusted
through a digital communication interface based on either a parallel or serial I2C [20]
communication protocol.
All of the features allow the use of this flexible controller in various applications, including
modern voltage regulator modules (VRMs) [21]-[23], multiple output converters for
communication devices and television sets as well as in portable electronics. In interleaved mode
the controller tolerates failures in up to three phases and it automatically switches to operation
with reduced numbers of phase (for example, from 4 to 3). Potentially, the dynamic reduction of
active converter phases can be exploited to improve efficiency at light and medium loads [24]
when up to three phases can be disabled. Although very valuable, these features have not been
presented in other MDPWM architectures [14], [25], [26], mostly due to the lack of solutions for
the operation with an odd number of phases and overly large hardware complexity. In the
following section, the operation of the multi-use controller IC is explained.
Figure 2.1: A block diagram of the multi-use and fault-tolerant digital controller IC regulating operation of a 4 phase interleaved buck converter.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 11
2.2 System Operation and Controller Architecture
Figure 2.1 shows the multi-use controller regulating operation of a 4-phase interleaved buck
converter. The controller consists of four analog-to-digital converters (ADCs) [27], four
programmable look-up table PID compensators [28,29], MDPWM, dead-time circuits, and
master management unit (MMU). The number of active ADCs and PID compensators is
regulated by the MMU, through external mode control and over-current protection signals (mode
and OCP). In interleaved mode, only one ADC and a compensator are used to regulate the
operation of all the phases. When the regulation of multiple outputs is required, a larger number
of these blocks are activated. The MMU generates clock signals for ADCs and PID
compensators, adjusts phase shifts of control signals, and shuts down critical phases if the OCP
signal, activated by a separate measurement circuits, is received. Based on the difference
between the output voltage references Vref, set by a sigma-delta digital-to-analog converter [27],
the ADCs produce error signals e[n] for PID compensators. The PID calculates duty ratio
commands for MDPWM. Depending on the mode of operation, the MDPWM creates up to 4
pulse-width modulated signals, whose duty ratios can be independently adjusted.
2.3 Multi-Phase Digital Pulse-Width Modulator
The architecture of the 4-phase MDPWM, shown in Fig. 2.2, is based on a modification of a
hybrid DPWM [29,30], in which a low-resolution counter and delay line are combined to create
a high-resolution pulse-width modulated signal. In this case, a programmable counter and a
synchronization block are introduced, both of which are shared by all phases to minimize
hardware complexity and improve matching between the phases.
Each phase contains a first-order Σ-∆ modulator [31]-[35], a programmable delay line, a
segmented delay matching circuit and a number conversion block. The system uses an external
clock signal whose frequency never exceeds nine times the switching frequency making
MDPWM power consumption relatively low. At the beginning of each switching cycle, in each
of the phases, a set pulse for the SR latch is created and the rising edge of the corresponding
dpwm signal cpmwi(t), where i=1,…,4, is created. The on-time duration is varied using the counter
and delay lines, which reset the latch. The core steps (3 most significant bits - MSBs) of the
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 12
Figure 2.2: A block diagram of the proposed multi-phase digital pulse-width modulator.
Figure 2.3: Phase synchronization: a) start signals during 4-phase interleaved operation; b) 3-phase interleaved operation.
desired 11-bit duty ratio value di[n] (i =1,..,4) are set by the counter, the fine adjustments (middle
5 bits) are performed through delay lines, and even finer ones (3 least significant bits - LSBs) are
obtained through Σ-∆ modulation. The mode of MDPWM operation depends on phase enable
and phase angle signals, which select the combination of active phases and the angles between
them, respectively. When the number of selected phases is 1, 2 or 4, the counter output changes
from 0 to 7. While operating with 3 phases, it counts from 0 to 8. Based on the phase angle
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 13
signal, the synchronization block creates set pulses spi that set SR latches. As an example, Fig.
2.3 illustrates set and counter’s output signals during interleaved operation with 4 and 3 phases
when phase shifts of 90° and 120° respectively are required.
2.3.1 Operation with 3 Phases and Number Conversion Logic
When operating in the single-phase mode or with an even number of phases, the creation of the
duty ratio value proportional to the 8-bit control input dc[n] (see Fig. 2.2) is quite simple. The
counter output goes through eight cycles and its ramping output r[n] is compared with the 3-
MSBs of dc[n] increased by phase angle value. When the two compared numbers are equal, pulse
δ(t) for the delay line is created. The propagation time of the pulse through the 32-cell-long delay
line is defined with the 5-MSBs of dc[n]. In the 3-phase mode, the situation is more complex.
Now, in each switching cycle the counter goes through 9 steps, which combined with 32 delays,
result in 288 different output duty ratio values. This number is higher than the number of
possible values for dc[n], creating a problem of assigning a duty ratio value to appropriate input.
If wrongly interpreted, the input values can cause non-linear or even non-monotonic input-to-
output DPWM characteristic and consequent closed-loop stability problems.
In order to generate a monotonic characteristic, for each input value dc[n], a portion of the
duty ratio increment is created by the counter and delay line. To determine this mapping, a
minimum-error criterion is used. Here, the difference between the desired increment and sum of
increments of the delay line ∆Dcn = Ncn[n]/9 and the counter ∆Ddl = Ndl[n]/256 is compared.
Where Ncn[n] is a 4-bit value controlling the number of counter steps before the delay line is
triggered and Ndl[n] is a 5-bit value defining the number of delay cells as shown in Fig. 2.2. More
precisely, we look for the minimum of the following function representing the absolute error in
dc[n] representation:
[ ] [ ]
+−=∆
2569256][ nNnNnd dlcnc
d . (2.1)
The solution of this equation gives a set of 256 values of Ncn[n] and Ndl[n] that result in the error
distribution shown in Fig. 2.4.a) limited to less than ±0.5 LSB. As a result, monotonic operation
is obtained as illustrated in Fig. 2.4.b). The values of Ncn[n] and Ndl[n] are stored in two look-up
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 14
tables used for generating proper increment portions during 3-phase operation.
Figure 2.4: The 3-phase MDPWM operation: a) the absolute duty cycle error vs. 8-bit duty ratio command dc[n]; b) actual duty cycle versus dc[n].
2.3.2 Dual-Biased Delay Cell for Wide-Frequency Range
One of the main challenges of DPWM architectures involving a delay line and a counter [36,37]
or segmented delay lines [38,39] is linearity.
When good matching between the counter time increment and the total propagation time of all
delay cells is not achieved, a non-monotonic characteristic can occur [36]. As a result, at certain
duty-ratio operating points, local stability problems [40] occur. In practice this undesirable
behavior is caused by fabrication defects and temperature variations. The delay-locked loop
(DLL) based structures are utilized [25], [37], [39], [41] to adjust the delay cells and allow linear
operation at programmable switching frequencies [41].
Except for the segmented delay-line DPWM [41], existing DLL-based DPWM
implementations are not designed for operation over a wide frequency range of the multi-use
controller from Fig. 2.1. To achieve the 8-bit resolution of the core DPWM (without sigma-delta)
in the frequency range between 100 kHz and 10 MHz, the delay cell propagation time tpd needs
to be varied significantly.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 15
To change the propagation time, current-starved delay cells [42], from Fig. 2.5.a) are often
employed. Their propagation time tpd is regulated by a programmable bias current source Ibias.
The finite steps ΔIbias of the current source are then further reduced through the mirroring stage
1/K1 (K1 >> 100), to obtain very precise control over tpd. The main problem of this circuit is that
it requires a large biasing current (~ 1 mA) to reduce tpd from 39 ns to 390 ps, corresponding
switching frequencies of 100 kHz to 10 MHz, respectively. Such a high bias current value is not
acceptable for low-power applications.
Figure 2.5: A delay cell with adjustable propagation time tpd: a) conventional current-starved delay cell b) proposed dual-biased current-starved delay cell.
To solve for this problem, a power efficient dual-bias delay cell is developed. The proposed
circuit is shown in Fig. 2.5.b). It consists of two CMOS inverters and a dual current mirroring
input stage that discharges the output equivalent capacitance seen at the node A. The propagation
time of a signal entering the cell is inversely proportional to the instantaneous current of the
mirroring stage im(t). This current is formed as a scaled sum of currents produced by two current
sources Icoarse, Ifine and during the delay cell transition period its value is
( )21 K
IKI
ti coarsefinem += , (2.2)
where current ratio K1 is larger than K2. In this way, the need for a single current source having a
wide current range and high power consumption, at high switching frequencies, is eliminated as
shown in Fig. 2.6. Still, a relatively high current im(t) ensuring short propagation time of delay
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 16
cells can be achieved by Icoarse. When long propagation times are required, Icoarse can be reduced
and a precise delay regulation can be achieved through Ifine adjustments. It should be noted that,
in this application, im(t) has a relatively small influence on the delay line’s power consumption.
This is because im(t) occurs only during short state transients, and in the targeted range of
switching frequencies its average value is small. This structure also provides more accurate
regulation of delay times. For large delays, conventional current starved delay cells have poor
regulation of delay times, due to inaccurate adjustment of low bias currents. In this case, this
problem is minimized.
Figure 2.6: Proposed adjustment of the current-starved delay cell current im(t) in the delay line versus the desired switching frequency fsw.
2.3.3 Segmented Bias Circuit
Current sources Icoarse and Ifine , introduced in Fig. 2.5, are designed to be digitally programmable
with fixed current increments ΔIfine and ΔIcoarse. The implementation of the bias circuit is shown
in Fig. 2.7. It can be integrated in deep sub-micron CMOS technologies, due to a requirement for
only two stacked transistors between supply rails. The current source Ifine, consists of 5 binary-
sized PMOS transistors and 20 equally-sized PMOS transistors. This arrangement in the
transistor sizing simplifies the digital logic that controls their operation while providing very
accurate and monotonic change of im(t) provided by Ifine. The precise adjustment of Ifine and tpd is
then achieved by turning on/off the binary-sized PMOS transistors using a 5-bit binary pmos
select input. Even finer current increments are obtained by using the 20-bit point pmos select
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 17
Figure 2.7: Digitally controlled segmented-bias circuit.
input tied to the equally-sized transistor. The coarse change of tpd is achieved by adjusting the 8-
bit range pmos select input. The transistors controlled with this input are sized in a thermometer
code fashion. This was implemented in order to guarantee monotonic behavior of tpd during
coarse bias current change. Additionally, to generate a smooth change of tpd when changing
Icoarse, the current ratio K2 of the right-side mirror has to be sized according to:
21
max
KI
KI coarsefine ∆
= . (2.3)
Due to the smaller current mirror ratio K2, the maximum value of Icoarse required to obtain the
smallest tpd (390 ps) is an order of magnitude smaller than that of the conventional cell, shown in
Fig. 2.5.a. The propagation delay tpd can be also accurately controlled. In this case, over the
proposed switching frequency range, the number of frequencies where propagation delay tpd is
accurately adjusted is 5120 (25 x 20 x 8). The effective frequency resolution of the delay-lock
loop is less than 2 kHz. If further improvement is desired, one can change the number and sizing
of biasing transistors and adjust the current mirror ratios K1 and K2.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 18
2.3.4 Digital Delay-Lock Logic
The block diagram of the digital delay-lock logic [37], [41] that adjusts the segmented bias
circuit based on the input external clock is shown in Fig. 2.8.a). During each switching period,
the reset pulse rpi(t) from the MDPWM is injected into the delay line. Depending on the delay
cell bias current im(t), the rising edge of rpi(t) travels through the delay line with a certain
propagation speed. If im(t) is set properly, when the falling edge of rpi(t) occurs 1/8∙Tsw after the
pulse was created, the rising edge of rpi(t) should reach the last delay line node n32. This situation
is illustrated in Fig. 2.8.b). Similarly, when the MDPWM operates in the three-phase mode, the
output of the last small cell (0.44∙tpd) at node n28a exhibits the rising edge 1/9∙Tsw after the pulse
was generated. However, if im(t) is larger than required, the pulse propagates faster through the
delay line. Consequently, when the falling edge of rpi(t) occurs, all delay cell outputs are set high
including the last two nodes n31 and n32. Similarly, if the bias current is lower, the pulse
propagates slower than desired and logic levels at both node n31 and n32 remain low. Therefore,
by observing only n31 and n32 during the falling edge of rpi(t), an appropriate decision about
increasing/decreasing the bias current can be made. Logic levels at n31 and n32 (1, 2, or 4 phases
are active) or n28 and n28a (3 phases are active) are sampled each switching cycle at the falling
edge of rp(t). Depending on the mode of operation (3-phase/4-phase), the sampled levels are fed
to a current adjust finite-state machine (FSM) in Fig. 2.8.a). The FSM then decides the
adjustment of the bias current for delay cells. For instance, if the total propagation time for the
delay line is not matched initially, the sampled logic levels at n31 and n32 are “00” ( rpi(t)
Figure 2.8: a) A block diagram of digital delay-locking logic; b) MDPWM delay line signals when 1, 2, or 4 phases are active.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 19
propagates too slow) or “10” (to be determined). The bias current is then gradually increased by
the FSM until “11” state (rpi(t) propagates too fast) is detected. The current level is then reduced
until state “10” is reached. In this way, the rising edge of the pulse at node n32 and falling edge of
rpi(t) are tuned as close as possible as shown in Fig. 2.8.b). The bias current is then considered
adjusted and further corrections are not performed unless state “00” or “11” are sensed again. In
the opposite case, if the initial bias current is too large and state “11” is detected, the bias current
is decreased until pulse slows down and state “10” is sampled for the first time. At that point, the
bias current for the delay line is “frozen” and delay line is locked.
2.4 Programmable Dead-Time Circuit A simplified block diagram of the programmable dead-time circuit generating non-overlapping
control signals c(t) and c’(t) is shown in Fig. 2.9. The non-overlapping clock generator circuit
[35] is modified to include two delay lines and two 16/1 multiplexers for dead time value
adjustment. Two multiplexers MUX 16/1 allow selection of the desired falling and rising dead
time values by adjusting the effective length of the delay lines. The maximum dead-time value
that can be obtained with 16 delay cells is 6.25% of Tsw. The dead-time increment is equal to
0.39% of the switching period.
Figure 2.9: Programmable dead-time circuit.
2.5 ADC Implementation The ADCs from Fig. 2.1 are implemented, as described in [27]. This low-power differential
delay-line ADC architecture is suitable for fabrication in deep sub-micron CMOS IC
technologies. To provide tight output voltage regulation (error ≤ 1%) of the digital loop, the
ADC quantization step scales with the analog voltage reference. Each of four analog ADC
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 20
references can be dynamically adjusted with four 10-bit Σ-Δ DACs interfaced with the MMU as
shown in Fig. 2.1. This allows the use of this controller in modern power management systems
with dynamic or adaptive voltage scaling [43].
2.6 IC Implementation
The digital controller of Fig. 2.1, was fabricated in TSMC 0.18-µm CMOS process. A
photograph of the fabricated chip is shown in Fig. 2.10.a) and its important parameters are
summarized in Table 2.1. The four-phase controller blocks occupy 1.72 mm2 of the silicon area,
which is comparable or even smaller than the area required for implementation of analog
solutions [44]. The utilized area can be further reduced by using custom-designed memory
blocks for storing controller parameters instead of flip-flop arrays and by time-sharing digital
hardware blocks (PID compensators, delay-lock loops, etc.) between phases. The measured chip
current consumption is 3.6 mA at the maximum switching frequency of 10 MHz when all 4
Table 2.1: Summary of the IC parameters.
Technology TSMC 0.18 µm CMOS Supply voltage 1.8 V / 3.3 V Switching frequency 100 kHz – 10 MHz No. of phases 4 Max. current consumption 3.6 mA @ 10 MHz Normalized current consumption 90.25 µA/MHz/per phase Controller silicon area 1.7 mm2
Figure 2.10: a) Fabricated chip die of the multi-use digital controller IC; b) Current consumption breakdown.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 21
phases are active and running separately. The current consumption breakdown is also presented
in Fig. 2.10.b). The normalized current consumption figure of 90.25 µA/MHz for each phase is
equivalent to the state-of-art analog solutions [16,17] and much smaller than commercial digital
controllers [18,19], that consume up to 50 mA when regulating four converter phases switching
at 2 MHz. Consequently, this controller could be used in portable applications [41] as well.
2.7 Experimental Results
To verify the operation of the controller IC, open-loop and closed-loop tests with four buck
converters are performed. The buck converter phases used for the closed loop tests are designed
to operate at the nominal switching frequency of 1 MHz and supply up to 5 A of the load current.
All desired controller parameters and configuration settings for different tests are loaded to the
on-chip memory via the built-in communication interface.
2.7.1 Open Loop Tests
To test the monotonic behavior and check linearity of the MDPWM the pulse-width modulated
output is first connected to a buck converter switching at 100 kHz. The MDPWM is set in the
three phase mode. The input 11-bit duty ratio command d[n] was gradually changed between
10% and 90% of its maximum value. The waveform shown in Fig. 2.11 demonstrates that the
output voltage changes linearly. Large non-monotonic regions caused by the MDPWM cannot be
observed due to the automatic delay adjustment performed by the digital delay-lock loop.
Figure 2.11: MDPWM linearity test at 100 kHz – Ch1: output converter voltage (1 V/div).
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 22
In the next step, the external clock frequency is increased in order to create a 10-MHz
switching signals. The input duty ratio command is now varied between four consecutive values
to produce pulse-width modulated signals shown in Fig. 2.12.a). From the zoomed part of the
waveform, shown in Fig. 2.12.b), it can be observed that the propagation time of delay cells is
properly adjusted to 390 ps as required for 8-bit resolution at 10 MHz. The measured current
consumption of one MDPWM phase operating at 10 MHz is 260 µA.
Figure 2.12: MDPWM operation at 10 MHz: a) the duty ratio command is changed between 4 consecutive values b) linearly distributed falling edges of the pulse-width modulated signals (8-bit resolution at 10 MHz).
2.7.2 Closed Loop Tests
The closed loop operation of the controller IC is tested for both multiple-output and interleaved
modes of operation. In the multiple-output mode, 4 buck converters operating at 1 MHz are used
to provide the output voltages of 1.2 V, 1.8 V, 2.5 V, and 3.3 V. The desired voltage references
are set digitally. Fig. 2.13.a) shows the captured waveforms. All output voltages are regulated/ at
their designated values. Fig. 2.13.b) shows the response of the controller when a phase voltage
reference is now dynamically modified through the communication interface. Once the data is
received by the controller, the MMU quickly updates the reference value fed to the dedicated Σ-
Δ DAC. As a result, the ADC reference voltage is increased from 1.5 V to 2.7 V and the
controller regulates the converter output voltage to reach the new steady state within 30 μs,
which is sufficiently fast for a most power saving techniques based on dynamic voltage
adjustment [43], [45], [46]. Finally, the interleaved mode of operation is first verified with two
phases enabled as shown in Fig. 2.13.c). The controller IC recognizes that only two phases are
active, and it adjusts phase shifts between control signals to Tsw/2 to reduce the output voltage
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 23
ripple. In the next step, two additional phases are enabled and phase shift is now again updated to
Tsw/4 by the MMU, as demonstrated in Fig. 2.13.d).
Figure 2.13: Closed-loop operation of the controller IC: a) four 1-MHz buck converters are regulated to produce four supply rails between 1.2 and 3.3 V; b) transient response of the controller when the voltage reference is dynamically changed; c) two-phase interleaved steady-state operation; d) four-phase interleaved steady-state operation;
2.7.3 Fault-Tolerant Operation
The fault tolerant operation is tested by intentionally generating the over-current protection
signal (OCP) (from Fig. 2.1) in one of the phases as shown in Fig. 2.14. Once the OCP is
detected, the faulty phase is turned off by the MMU. The MMU then observes the remaining
number of phases and starts updating phase angles for all active phases until all control signals
are shifted by 1/3 of the switching period. Similarly, if one more phase is turned off, the MMU
will adjust the phase shift to one half of the switching period. The automatic phase shift
reconfiguration can be also utilized for optimizing the multi-phase converter efficiency when the
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 24
number of enabled phases varies with the load current. In other words, at light load currents up to
three phases can be turned off [24] to reduce switching losses and improve the efficiency.
Figure 2.14: Fault-tolerant operation in the closed loop – Ch1: output converter voltage vout(t) at 3.3 V (500 mV/div); Ch2: Output converter voltage vout(t) – AC component (50 mV/div); D1-D4: MDPWM control signals switching at 1 MHz; D5 – OCP signal; Time scale is 2 μs/div.
2.8 Conclusion In this chapter a flexible multi-phase/multi-stage digital controller IC having low power
consumption and occupying a small silicon area is presented. The controller can be used in
various applications including portable electronic devices. To achieve these characteristics, novel
architecture of a multi-phase DPWM is developed and combined with a newly designed current
starved delay cell. The performances of the controller IC are experimentally verified on several
experimental setups, including multiple-output and interleaved dc-dc converters.
REFERENCES
[1] A.V. Peterchev, S.R. Sanders, “Digital loss-minimizing multimode synchronous buck converter,” in Proc. IEEE Power Electronics Specialists Conf., 2004, pp.20-25.
[2] V. Yousefzadeh D. Maksimović, “Sensorless optimization of dead times in DC-DC
converters with synchronous rectifiers,” in Proc. IEEE Applied Power Electronics Conf., 2005, pp. 911-917.
[3] A. Prodić and D. Maksimović, “Digital PWM controller and current estimator for a low-
power switching converter,” in Proc. IEEE Computer in Power Electronics Workshop, 2000, pp. 123-128.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 25
[4] W. Stefanutti, P.Mattavelli, S. Saggini, and M. Ghioni, “Autotuning of Digitally Controlled Buck Converters Based on Relay Feedback,” in Proc. IEEE Power Electronics Specialists Conf., 2005, pp. 2140-2145.
[5] B. Miao, R. Zane, D. Maksimović, “System identification of power converters with digital
control through cross-correlation methods,” IEEE Trans. Power Electron., vol. 20, pp. 1093-1099, Sept. 2005.
[6] A.L. Kelly, K. Rinne, “A self-compensating adaptive digital regulator for switching
converters based on linear prediction,” in Proc. IEEE Applied Power Electronics Conf., 2006, pp.712-718.
[7] Zhenyu Zhao, A. Prodić, “Limit-cycle oscillations based auto-tuning system for digitally
controlled DC-DC power supplies,” IEEE Trans. Power Electron., vol. 22, pp. 2211–2222, Nov. 2007.
[8] A. Prodić, D. Maksimović, and R.W Erickson, “Digital controller chip set for isolated DC
power supplies,” in Proc. IEEE Applied Power Electronics Conf., 2003, pp. 866–872. [9] A. Soto, P. Alou, J.A. Cobos, “Non-Linear Digital Control Breaks Bandwidth Limitations,”
in Proc. IEEE Applied Power Electronics Conf., 2006, pp. 724-730. [10] G. Feng, E. Meyer, and Y.-F. Liu, “A new digital control algorithm to achieve optimal
dynamic performance in DC-to-DC converters,” IEEE Trans. Power Electron., vol. 22, pp. 1489–1498, July 2007.
[11] Zhenyu Zhao, A. Prodić, “Continuous-time digital controller for high-frequency DC-DC
converters,” IEEE Trans. Power Electron., vol. 23, pp. 564–573, Mar. 2008. [12] L. Corradini, P. Mattavelli, E. Tedeschi, D. Trevisan, “High-bandwidth multisampled
digitally controlled DC-DC converters using ripple compensation,” IEEE Trans. Ind. Electron.,vol. 55, pp. 1501–1508, Apr. 2008.
[13] A. Babazadeh, D. Maksimović, “Hybrid digital adaptive control for fast transient response
in synchronous buck DC–DC converters,” IEEE Trans. Power Electron., vol. 24, pp. 2625 – 2638, Nov. 2009.
[14] A.V. Peterchev, J. Xiao, S.R. Sanders, “Architecture and implementation of a digital VRM
controller,” IEEE Transactions on Power Electronics, vol.18, issue 1, pp. 356 – 364, Jan. 2003.
[15] J. A. A. Qahouq, L. Huang, D. Huard, A. Hallberg, “Novel current sharing schemes for
multiphase converters with digital controller implementation,” in Proc. IEEE Applied Power Electronics Conf., 2007, pp. 148–156.
[16] Data Sheet, ISL6264, “Two-phase core controller for AMD mobile Turion CPUs,” Intersil
Corp.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 26
[17] Data Sheet, TPS5210, Synchronous Buck Controller for Pentium Processors, Texas
Instruments Inc. [18] Data Sheet, UCD9240, Digital power point of load system controller, Texas Instruments
Inc. [19] Data Sheet, ZL2005, Step-down DC-DC Controller with power management, Zilker Labs. [20] Data Sheet, I2C bus specification, version 2.1, Philips Semiconductors. [21] Y. Panov, M. Jovanović, "Design considerations for 12-V/1.5-V, 50-A voltage regulator
modules," IEEE Transactions on Power Electronics, vol. 16, issue 6, pp. 776 – 783, Nov. 2001.
[22] Data Sheet, FDMF8700, Driver plus FET Multi-chip Module, Fairchild Semiconductors. [23] Data Sheet, PIP212-12M, DC-to-DC converter powertrain, NXP Semiconductors. [24] P. Zumel, C. Fernandez, A. de Castro, O. Garcia, “Efficiency improvement in multiphase
converter by changing dynamically the number of phases,” in Proc. IEEE Power Electronics Specialists Conf., 2006, pp. 1-6.
[25] R. Kelley, K. Rimme, R.C. Kavanagh, W.P. Marnane, M.G. Egan, ”Multiphase digital
pulsewidth modulator,” IEEE Transactions on Power Electronics, vol. 21, issue 3, pp. 842 – 846, May 2006.
[26] T. Carosa, R. Zane, D. Maksimović, “Implementation of a 16 Phase Digital Modulator in a
0.35μm Process,” in Proc. IEEE Computer in Power Electronics Workshop, 2006, pp.159-165.
[27] A. Parayandeh, A. Prodić, “Programmable Analog-to-Digital Converter for Low-Power
DC–DC SMPS,” IEEE Transactions on Power Electronics, vol. 23, issue 1, pp. 500 – 505, Nov. 2001.
[28] A. Prodić, D. Maksimović, "Design of a digital PID regulator based on look-up tables for
control of high-frequency DC-DC converters," in Proc. IEEE Computers in Power Electronics Conf., June 2002, pp. 18-22.
[29] B. Patella, A. Prodić, A. Zirger, D. Maksimović, ”High-frequency digital controller PWM
controller IC for DC-DC converters,” IEEE Trans. Power Electronics, Special Issue on Digital Control, vol. 18, pp. 438-446, Jan. 2003.
[30] A. P. Dancy, R. Amirtharajah, A.P. Chandrakasan, “High-efficiency multiple-output DC-
DC conversion for low-voltage systems,” IEEE Transactions on Very Large Scale Integration (VLSI) Systems, vol.8, issue 3, pp. 252 – 263, June 2000.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 27
[31] Z. Lu, Z. Qian, Y.Zeng, W. Yao, G. Chen, Y. Wang, “Reduction of digital PWM limit ring with novel control algorithm,” in Proc. IEEE Applied Power Electronics Conf., 2001, pp. 521 – 525
[32] Z. Lukić, K. Wang, A. Prodić, “High-frequency digital controller for dc-dc converters
based on multibit sigma-delta pulse-width modulation,” in Proc. IEEE Applied Power Electronics Conf., 2005, pp. 35-40.
[33] A. Kelly, K. Rinne, “High Resolution DPWM in a DC-DC converter application using
digital sigma-delta techniques,” in Proc. IEEE Power Electronics Specialists Conf., 2005, pp. 1458-1463.
[34] Z. Lukić, “Sigma-Delta DPWM Controllers for 12 MHz DC-DC Switch-Mode Power
Supplies”, M.Sc. thesis, University of Toronto, May 2006. [35] D.A. Johns and K. Martin, Analog Integrated Circuit Design, Wiley, 1997. [36] A. Syed, E. Ahmed. D. Maksimović, E. Alarcon, “Digital Pulse-Width Modulator
Architectures,” in Proc. IEEE Power Electronics Specialists Conf., vol.6, pp. 4689-4695. June 2004.
[37] V. Yousefzadeh, T. Takayama, D. Maksimović, “Hybrid DPWM with Digital Delay-
Locked Loop,” Proc. IEEE Computer in Power Electronics Workshop, 2006, pp. 142-148. [38] O. Trescases, G. Wei, W.T. Ng, “A Segmented Digital Pulse Width Modulator with Self-
Calibration for Low-Power SMPS,” in Proc. IEEE International Conference on Electron Devices and Solid-State Circuits, pp. 367-370, Dec. 19-21, 2005
[39] K. Wang, N. Rahman, Z. Lukić, A. Prodić, "All-digital DPWM/DPFM controller for low-
power DC-DC converters," in Proc. IEEE Applied Power Electronics Conf., 2006, pp. 719-723.
[40] A. Peterchev, S. Sanders, “Quantization resolution and limit cycling in digital controlled
PWM converters,” in Proc. IEEE Power Electronics Specialists Conference, vol. 2, 2001, pp. 465–471.
[41] O. Trescases, “Integrated power-supplies for portable applications,” Ph.D. thesis,
University of Toronto, 2007. [42] M. Maymandi-Nejad, M. Sachdev, “A digitally programmable delay element: design and
analysis,” IEEE Transactions on Very Large Scale Integration (VLSI) Systems, vol. 11, issue 5, pp. 871 – 878, Oct. 2003.
[43] T. Burd, T. Pering, A. Stratakos, and R. Brodersen, “A dynamic voltage scaled
microprocessor system,” in IEEE Journal of Solid-State Circuits, vol. 35, no. 11, pp. 1571-1580, Nov. 2000.
CHAPTER 2. MULTI-USE AND FAULT-TOLERANT DIGITAL CONTROLLER IC 28
[44] Kuo-Hsing Cheng, Chia-Wei Su, and Hsin-Hsin Ko, “A high-accuracy and high-efficiency on-chip current sensing for current-mode control CMOS DC-DC buck converter”, IEEE 15th International Electronics, Circuits and Systems Conference, 2008, pp. 458-461.
[45] Design Guidelines, “Voltage regulator module (VRM) and enterprise voltage regulator-down (EVRD) 11.1”, Intel Corporation.
[46] A. Soto, A. de Castro, P. Alou, J. A. Cobos, J. Uceda, A. Lotfi, ”Analysis of the buck converter for scaling the supply voltage of digital circuits,” IEEE Trans. Power Electronics, vol. 22, pp. 2432-2443, Nov. 2007.
29
Chapter 3 Dynamic Efficiency Optimization for Multi-Phase Converters
3.1 Introduction The efficiency of a typical multi-phase dc-dc switch-mode power supply (SMPS) used in
telecommunication devices, consumer electronics, and personal computers depends on its load
[1]-[3]. Even though the supplied devices usually do not take constant power at all times, the
converters are often designed to be most efficient at a certain load (usually maximum). As a
result the efficiency at light and medium loads is degraded. In modern systems this causes
significant losses, since the devices operate in suboptimal modes over large time intervals.
In multi-phase systems, utilized for high-current applications [4], the load current is usually
shared equally among several converter stages [5]-[8], to reduce the inductor current ripple [9],
stress on components, and improve dynamic response. To optimize efficiency of multiphase
converters over the full load range, several approaches have been proposed. The phase
shadowing techniques [10] improve the efficiency of the converter with uniform current sharing
by switching off phases at lighter loads. This technique provides a significant efficiency
improvement over the full-range of operation but requires a relatively large number of phases to
achieve a flat efficiency curve. The method based on non-uniform current sharing [11] utilizes
multiple power stages with different current ratings. To improve the efficiency in this
implementation, the phases are switched on and off in a predermined fashion similar to the phase
shadowing method while the load current is distributed among converter phases by a current
sharing loop according to their current ratings. This method results in a smaller number of phases
but the shape of the efficiency curve is degraded.
However, in both of the abovementioned methods the power stages are presented but the
controller implementation issues have not been addressed. In particular, controller stability
problems [12] during phase on/off transients, which will be addressed soon, cannot be solved in
a simple manner. Hence, the authors demonstrate steady-state operation of the presented
architectures only and suggest possible controller implementations.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 30
The main goals of this chapter are to address and solve the problems of practical controller
implementation in multi-phase converters and to show a new system that results in a small
number of phases having both a flat and optimized efficiency curve. To achieve these
characteristics the system, shown in Fig. 3.1, utilizes two key elements: a multi-phase digital
current program-mode based controller, which does not require analog-to-digital converters for
the inductor current measurements, and a power stage with logarithmic current sharing. The
system employs N parallel converters operating as binary-weighted constant current sources
based on a concept similar to the method previously used for designing high-frequency resonant
converters [13]. Each of the N phases is optimized by selecting the size of semiconductor
switches, the inductor value, and the switching frequency such that the maximum efficiency at its
designated current Ii = 2i−1 ∙Inom, is achieved, where i = 1, 2,…, N. The instantaneous number of
phases operating at any point of time is dynamically regulated by the digital current program
mode controller (DCPM). Depending on the load current (Iload) requirements, the controller
generates a digital control variable itot[n] that enables or disables the phases, such that Iload = ΣIi.
The state of each phase is controlled through phase enable signals s1, s2,…, sN. In this
implementation, s1 corresponds to the least significant bit (LSB) of itot[n] and sN, controlling the
current of 2N−1∙Inom, is the most significant bit (MSB). Since each of the converters individually
operates at the most efficient point, in this way, the optimal efficiency over the full range of
Figure 3.1: Block diagram of a digitally controlled multi-phase converter with logarithmic current sharing.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 31
operation is dynamically achieved. Also, as discussed in the following section, the hardware
requirements for a relatively complex current loop are minimized.
3.2 System Architecture
Fig. 3.2 shows a 4-phase implementation of the proposed system. Its controller has a digital
voltage loop containing an analog-to-digital converter (ADC) for the output voltage error e[n]
measurement and a PI compensator producing the signal itot[n], controlling the total current of
the converter. The sampling of the output voltage and the update of itot[n] is performed at the
frequency equal to the rate of the fastest-switching converter phase.
Compared to the traditional implementation of a fully-digital current programming controllers
(DCPM) [14]-[16], which requires multiple ADCs for the phase current measurements, the
system of Fig. 3.2 is much simpler. It eliminates the need for a large number of fast ADCs and
Figure 3.2: Detailed system architecture of the proposed controller with a logarithmic current sharing.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 32
instead, as shown in Fig. 3.2, uses a set of comparators with thresholds vnom, 2vnom, and 4vnom that
are proportional to the binary weighted currents. As a result, the peak current-mode control [17]
in all phases is achieved. It should be noted that the elimination of a large number of ADCs
greatly simplifies the controller implementation and complexity. On the other hand, the
comparators of Fig. 3.2 can be fairly simple. They need to be fast but not necessarily very
accurate. Any offset in the comparator threshold is automatically compensated by the voltage
loop and in most cases has only a negligible effect on the phase efficiency.
To provide accurate current regulation and eliminate the stability problem related to the phase
toggling, which will be addressed in the following sections, a digital-to-analog converter (DAC),
an additional low-current phase, and a hysteretic logic block followed by a transient current
estimator and a phase enable corrector blocks are added. Similar to conventional
implementations [17], the controller also has current amplifiers and an SR latch, whose operation
is either enabled or disabled with the phase enable signal si.
3.3 Practical Implementation
One of the advantages of the new controller architecture over the voltage-mode controllers
[10,11] is the simplicity of the compensator implementation. This can be explained by looking at
the control-to-output transfer function of voltage-mode controlled N-phase buck converter [17]
( )( )
20
2
00
1
1)(
ωω
ωs
Qs
s
Vsdsv
sG esrin
outvd
++
+⋅== , (3.1)
where the corner frequency ω0 is
CNL⋅
=1
0ω . (3.2)
It can be seen that the corner frequency ω0 depends on phase inductance L, total output
capacitance C, as well as on the number of active phases N. This dependence on the number of
active phases dynamically changes “transfer function” and creates a serious control problem in
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 33
voltage mode controlled converters using efficiency optimization schemes [10,11] based on the
phase shadowing method. To provide stability under all operating conditions, a slow
compensator is often used, meaning that the dynamic performance of the system is sacrificed to
improve power processing efficiency.
The current-mode controller of Fig. 3.2 does not suffer from the phase-dependent transfer
function variation problem. In this system the phases behave as control-signal dependent current
sources [17], [21] connected to the parallel connection of the load resistance R and the output
capacitance C. The small-signal first-order transfer function Gvic(s) is shown [17] to be:
( )
p
esr
c
outvic s
s
Rsisv
sG
ω
ω
+
+⋅==
1
1
)()( , (3.3)
where the pole frequency ωp is inversely proportional to the RC product:
RCp1
=ω . (3.4)
3.3.1 Accurate Current Regulation
The main problem of the architecture shown in Fig. 3.1 is the accuracy of current regulation.
Since the current can be changed in discrete steps only, related limit cycling problems affecting
system stability and output current/voltage regulation can occur [22]. To eliminate the
quantization effects without a significant increase in the number of phases, the originally
proposed structure is modified as shown in Fig. 3.2. A phase with variable current that can be
continuously changed from 0 to 1.5Inom is added and, for the 4-phase implementation, the
remaining three phases are scaled as Inom, 2Inom, and 4Inom. As described in the following section,
the rating of the variable phase is selected such that jittering of the system is eliminated.
To achieve the desired current regulation, in this case with an 11-bit resolution, the 3 MSBs of
the control signal are used as phase enable/disable variables and the 9 LSBs are fed into a single-
bit Σ-∆ DAC [23], which sets the reference for the phase with variable current. It should be noted
that the implementation of the DAC is significantly simpler than that of an ADC [23,24] and its
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 34
introduction has a relatively small effect on the system complexity. Also, since the power rating
of the variable-current phase is small, its wide-range operation does not significantly affect the
system efficiency.
3.3.2 Jitter Elimination
An additional difficulty in implementing the proposed controller is jittering (chattering) of the
control signal itot[n]. It occurs when the PI controller frequently changes its output between two
approximate values resulting in a phase reconfiguration. For example, assume that a light load
change requires the total inductor current, i.e. current reference itot[n], to change between
3.99Inom and 4.01Inom. Initially, to provide a current of 3.99Inom, two constant current phases are
switched on to produce Inom, 2Inom and the variable current phase produces 0.99Inom. To increase
the current to 4.01Inom, the 4Inom can be turned on and the remaining part, of 0.01Inom, can be
provided by the variable current phase. However, such an operation is undesirable since it
requires inductor currents of all constant-current phases to change from rated values to zero or in
opposite direction. This abrupt change of all currents can negatively affect the output voltage
regulation, as shown in Fig. 3.3.
Figure 3.3: The output voltage regulation is affected by the jitter (shown in the red circle) of itot[n].
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 35
For this reason, a hysteretic logic block of Fig. 3.2 is introduced, and the maximum current of
the variable-current phase is set to 1.5Inom. The operation of the hysteretic logic that creates the
actual phase enabling signal is described using Fig. 3.4.
Figure 3.4: Operation of the hysteretic logic – output phase enable signal versus input control value itot[n].
3.4 Transient Operation
Sudden load current changes ΔIload generate output voltage disturbances. To keep the output
voltage tightly regulated, the PI compensator from Fig. 3.2 immediately reacts by adjusting the
digital command itot[n] until the output voltage returns to steady state (e[n]=0). To achieve a fast
transient minimizing voltage deviation ΔV, it is necessary for the actual total current itot(t)=ΣiLi(t)
from all active phases to quickly follow the digital command itot[n]. This condition is challenging
to satisfy because the current slew rates are limited by the phase inductances and input-output
voltage conditions. For example, in a buck converter, the rising slope Δ1 of a phase current is
significantly larger than the falling slope Δ2 due to large difference between the input voltage vin
and the output voltage vout. The slope Δ1 and Δ2 can be calculated as:
L
vv outin −=∆1 , (3.5)
Lvout=∆ 2 . (3.6)
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 36
The effect of current slopes on itot(t) when the digital current command itot[n] is stepped down
from 5.4Inom to 3.6Inom is illustrated in Fig. 3.5. From Fig. 3.5, such a change in the itot[n] requires
that the largest phase 4Inom is disabled while phases 2Inom and Inom are enabled and the variable
phase is adjusted from 1.4Inom to 0.6Inom. The phases that are enabled quickly reach their nominal
currents within a single switching cycle Tsw since Δ1 is large due to vin>>vout. On the other hand,
for the largest phase it takes several switching cycles of the variable phase until the current in
that phase reaches zero. As a result, itot(t) initially goes in the opposite direction of itot[n],
creating an undesirable large voltage overshoot that will be demonstrated in Section 3.5.
Figure 3.5: The effect of finite rising Δ1 and falling current slope Δ2 on itot(t) for a step of the digital current command itot[n] from 5.4Inom A to 3.6Inom.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 37
To eliminate this problem, two new blocks: phase enable corrector and transient current
estimator are added into the system as shown in Fig. 3.2. The role of the transient current
estimator is to calculate phase currents i4Inom[n], i2Inom[n], iInom[n] and ivar[n] and their total sum
isum[n] during the load transient. This can be achieved by monitoring the digital current command
itot[n-1] and the 4-bit corrected phase enable [n-1] command calculated in the previous switching
cycle. For example, if a corrected phase enable bit associated to a specific phase, changes from 1
to 0, the current in that phase starts to decrease from its nominal value at a rate equal Δ2 ∙ Tsw, in
each switching cycle. Similarly, based on the rising slope Δ1 the phase current can be estimated
when the phase is enabled again. Finally, by summing up all estimated phase currents, isum[n] is
obtained. The value of isum[n] is a digital equivalent of the actual total current itot(t) fed to the
load during the transient. To improve the accuracy of the estimation, when the converter reaches
steady state (e[n]=0 for several switching cycles), the current values for each phase are calibrated
using itot[n] from the PI compensator.
Simultaneously, based on the estimated currents, the phase enable corrector tries to match the
estimated current sum isum[n] to the digital current command itot[n] as close as possible. To
achieve this, it calculates necessary correction of the phase enable signal and the proper current
reference iref1[n] for the variable phase. The decision process starts by calculating the difference
δmax between the current command itot[n] and estimated current sum isum[n] less the estimated
current in the variable phase ivar[n]:
])[][(][ varmax ninini sumtot −−=δ . (3.7)
The value of δmax indicates the value of the maximum current increment that can be handled by
fixed-current phases 4Inom, 2Inom and Inom. Then by comparing the states of phase enable
command and the previous corrected phase enable command and by using δmax, phases are
enabled/disabled in such a way that the sum of all individual current increments in the fixed
phases δest = δ4 + δ2 + δ1 (δ4, δ2, and δ1 are obtained from Δ1 and Δ2 and current levels in the
phases during transient) does not exceed δmax. In the final step, the reference iref1[n] for the
variable phase applied in the next switching cycle is calculated as:
[ ]estsumtotref nininini δ+−−= ])[][(][][ var1 . (3.8)
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 38
Note that iref1[n] cannot exceed 1.5Inom and therefore if iref1[n] becomes larger than 1.5Inom it is
saturated to 1.5Inom.
Fig. 3.6 shows the simulated operation of the controller during a heavy-to-light load transient
between 5.4Inom and 3.6Inom. The PI compensator reacts to the increasing voltage deviation and
decreases itot[n] to the vicinity of the new load current level. Therefore the largest phase 4Inom
needs to disabled while phases 2Inom and Inom enabled. To perform the phase reconfiguration and
improve the converter efficiency without increasing the voltage deviation, the phase enable
corrector and transient current estimator first discharge the inductor current in the largest phase,
and then sequentially enable phases Inom and 2Inom as shown in Fig. 3.6. As a result, the multi-
phase converter is dynamically readjusted to operate at the most efficient phase configuration,
while providing small voltage deviation and fast response.
Figure 3.6: Simulated transient operation of the controller during a heavy-to-light load transient between 5.4Inom and 3.6Inom.
3.5 Design of Converter Phases Converter phases (i.e. power MOSFETs, gate driver circuit, the inductor and the phase switching
frequency) for the proposed system from Figs. 3.1 and 3.2, are selected to obtain high efficiency
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 39
based on the practical converter design guidelines given in [25]. In particular, the power
MOSFETs and gate driver circuits are chosen such that each phase operates at high efficiency
around its nominal operating current as illustrated in Fig. 3.7.a). To improve the overall
efficiency, the switching frequency of the largest phase is reduced to be twice lower than the
phase operating at 2Inom. On the other hand, to provide fast transient response, the variable and
Inom phase are configured to operate at the switching frequency 1.3 times faster than 2Inom phase.
The resulting efficiency curve of the complete system is shown in Fig. 3.7.b). It can be seen that
the resultant efficiency characteristic is improved compared to individual phase efficiency
characteristics and it is nearly constant for most of the load current range allowing for significant
energy loss reductions especially at light and medium load currents. The efficiency simulations,
presented in Fig. 3.7 are performed using loss models, in which detailed switching and
conduction losses of the power stages, as well as those of the gate drive circuits are included.
The models are developed based on the practical guidelines provided in [25].
The non-identical switching frequencies and non-uniform rated currents of the converter
phases impose a larger overall current ripple injected into the output capacitor. To provide small
output voltage ripple, a larger output capacitor is required. However, in portable applications, the
additional cost/size associated with the increased output capacitor can be compensated with the
Figure 3.7: a) Simulated efficiency characteristics of the converter phases operating at different switching frequencies b) Simulated efficiency of the whole system.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 40
reduced battery size due to improved power supply efficiency. In practice, the number of phases,
their rated nominal currents, and switching frequencies can be further customized to suit a
particular application and expected load behavior.
3.6 Experimental System and Results Based on the block diagram of Fig. 3.2 an experimental 4-phase 40-A, 12 V-to-1.8 V system was
built. All digital blocks (PI compensator, hysteretic logic, phase enable corrector and transient
current estimator) are implemented with an Altera FPGA DE2 board as well as the DAC that
also uses an external reference and an RC filter. The main characteristics of the prototype buck
converter are listed in Table 3.1. The nominal current Inom is set to be 5 A, and the switching
frequencies of all stages but the two largest ones are the same.
Table 3.1: Important parameters of the 4-phase logarithmic buck converter
phase current [A]
fsw [kHz]
L [μH]
C [μF]
Ivar 0-7.5 650 0.9
800 Inom 5 650 0.9 2Inom 10 500 0.9 4Inom 20 250 0.9
3.6.1 Steady-State Operation
The steady-state converter operation for two different output load current is shown in Figs. 3.8.a)
Figure 3.8: Steady-state operation with two different load currents: a) 39 A b) 12 A; Ch.1: Output voltage (500 mV/div); Ch.2, Ch.3 and Ch.4: inductor current of variable phase, phase 2Inom, phase 4 Inom respectively – 6.66 A/V; D1-D4: Gate drive signals of all four phases. Time scale is 2 μs/div.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 41
and 3.8.b). Fig. 3.8.a) shows the case when the output load current is 39 A, and all the phases are
turned on (4Inom = 20 A, 2Inom = 10 A, Inom = 5 A, and the current of the variable phase is Ivar = 4
A). The other case shows the situation when the load current is reduced to 12 A. To improve the
efficiency, the controller now turns off the phases 2Inom and 4Inom. A tight output voltage
regulation in both cases can be observed due to the operation of the variable phase that
dynamically changes to accommodate the difference between the load current and other phase
currents.
3.6.2 Transient Operation
To test the dynamic behavior of the proposed system and verify proper operation of the phase
enable corrector and the transient current estimator, both blocks are intentionally disabled first.
Then the output load is stepped down from 21 A to 19 A. The controller response is shown in
Fig. 3.9.a). As it is predicted in Section 3.4, due to the inappropriate transition in the inductor
currents, the output voltage exhibits a large overshoot of 150 mV although the load change is
only 2 A. In the next step, the phase enable corrector and the transient current estimator are
enabled and the controller response is tested again. The voltage deviation is now reduced by a
factor of 6 to 25 mV due to the operation of these blocks as shown in Fig. 3.9.b). The subsequent
phase reconfigurations are also prevented by the operation of hysteretic logic.
Figure 3.9: Transient response for a load step from 21 A to 19 A when the phase enable corrector and transient current estimator are: a) disabled b) enabled; Ch.1: Output voltage (200 mV/div); Ch.2, Ch.3 and Ch.4: inductor current of variable phase, phase 2Inom, and phase 4 Inom respectively – 6.66 A/V; D1-D4: Gate drive signals of all four phases. Time scale is 10 μs/div.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 42
Figure 3.10: Transient response: a) from 9 A to 38 A; b) from 38 A to 9 A; Ch.1: Output voltage (200 mV/div); Ch.2, Ch.3 and Ch.4: inductor current of variable phase, phase 2Inom, and phase 4 Inom respectively – 6.66 A/V.
Finally, the converter operation is also verified with a large light-to-heavy (9 A – 38 A) and
heavy-to-light load step (38 A – 9 A) as shown in Figs. 3.10.a) and 3.10.b) respectively. During
the load transient, since the total current command itot[n] is dynamically changing to
accommodate new load conditions, the phases are turned on and turned off until the output
voltage settles down and itot[n] becomes constant. The response time is around 30 μs while the
maximum voltage deviation is 200 mV. Fast response of variable and Inom phases due to the
higher switching frequency helps also to reduce the peak of the voltage drop at the output
capacitor during the load transient.
3.6.3 Measured Converter Efficiency
Fig. 3.11.a) shows the measured efficiency of the converter with logarithmic current sharing and
that of an equivalent 4-phase power stage with the uniform current distribution. It can be seen
that the converter with logarithmic current sharing has a virtually flat characteristic over the
analyzed range of operation and results in an efficiency improvement of up to 25% at light loads,
and about 6% at medium loads. Compared to a 4-phase converter, switching at 500 kHz and
utilizing a phase shadowing method [10] for efficiency optimization, the converter with the
logarithmic current sharing provides on average a 1.5% efficiency improvement as illustrated in
Fig. 3.11.b) when the output load current is slowly varying. As the frequency of load disturbance
changes increases, the efficiency improvement for the logarithmic current sharing method
increases due to faster selection of the optimum number of the active converter phases.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 43
Figure 3.11: Measured efficiency characteristics of the converter based on: a) logarithmic current sharing and uniform current sharing b) logarithmic current sharing and phase shadowing.
3.7 Conclusion In this chapter, a current-mode based digital controller and power stage with logarithmic current
sharing are introduced. The controller dynamically configures the number of active phases to
improve the efficiency of the converter. It is shown that by using a relatively simple controller
and a small number of phases a virtually flat efficiency characteristic can be achieved. The
digital controller requires no analog-to-digital converters for inductor current measurements and,
as such, is suitable for systems operating at high switching frequencies. In addition, due to the
use of the current-program mode, potential stability problems that exist for similar voltage mode
configurations are eliminated. Quantization effects and phase toggling problems existing due to
coarse current adjustments are addressed and resolved. The new system is implemented on a 4-
phase prototype and efficiency improvements and good dynamic characteristics are verified.
REFERENCES
[1] Y. Panov, M. Jovanović, “Design considerations for 12-V/1.5-V, 50-A voltage regulator modules,” IEEE Trans. Power Electron., vol. 16, pp. 776 – 783, Nov 2001.
[2] Peng Xu, Jia Wei, F.C. Lee, “Multiphase coupled-buck converter-a novel high efficient 12
V voltage regulator module,” IEEE Trans. Power Electron., vol. 18, pp. 74 – 82, Jan 2003.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 44
[3] Z. Xunwei, M. Donati, L. Amoroso, F.C. Lee, “Improved light-load efficiency for synchronous rectifier voltage regulator module,” IEEE Trans. Power Electron., vol. 15, pp. 826 – 834, Sept. 2000.
[4] X. Zhou, P.-L.Wong, P. Xu, F. C. Lee, A. Q. Huang, “Investigation of candidate VRM
topologies for future microprocessors,” IEEE Trans. Power Electron., vol. 15, pp. 1172–1182, Nov. 2000.
[5] S. Luo, Z. Ye, R. Lin, F. C. Lee, “A classification and evaluation of paralleling methods for
power supply modules,” in Proc. IEEE Power Electronics Specialists Conf., vol. 2, 1999, pp. 901–908.
[6] Jung-Won Kim, Hang-Seok Choi, Bo Hyung Cho, “A novel droop method for converter
parallel operation,” IEEE Trans. Power Electron., vol. 19, pp. 25 – 32, Jan 2002. [7] J. Abu-Qahouq, Hong Mao, I. Batarseh, “Multiphase voltage-mode hysteretic controlled
DC-DC converter with novel current sharing,” IEEE Trans. Power Electron., vol. 19, pp. 1397 – 1407, Nov 2004.
[8] Hong Mao, Liangbin Yao, Caisheng Wang, I. Batarseh, “Analysis of inductor current
sharing in nonisolated and isolated multiphase DC–DC converters,” IEEE Trans. Power Electron., vol. 54, pp. 3379 – 3388, Dec. 2007.
[9] J.A. Oliver, P. Zumel, O. Garcia, J.A. Cobos, J. Uceda, “Passive component analysis in
interleaved buck converters,” in Proc. IEEE Applied Power Electronics Conf., 2004, pp. 623 - 628.
[10] P. Zumel, C. Fernandez, A. de Castro, O. Garcia, “Efficiency improvement in multiphase
converter by changing dynamically the number of phases,” in Proc. IEEE Power Electronics Specialists Conf., 2006, pp. 1-6.
[11] J.A. Abu Qahoug, L. Huang, “Highly efficient VRM for wide load range with dynamic
non-uniform current sharing,” in Proc. IEEE Applied Power Electronics Conf., 2007, pp. 543 - 549.
[12] Wenkai Wu, “Multiphase voltage regulator control and design Considerations,” in
Professional Education Seminars Workbook, IEEE Applied Power Electronics Conf., 2009, vol. 2, seminars 7-12, pp. 33 - 37.
[13] J.M. Rivas, R.S. Wahby, J.S. Shafran, D.J. Perreault , “New architectures for radio-
frequency DC–DC power conversion,” IEEE Transactions on Power Electronics, vol. 21, pp.380 – 393, March 2006.
[14] H. Peng, D. Maksimović, "Digital current-mode controller for DC-DC converters," in Proc.
IEEE Applied Power Electronics Conf., 2005, pp.899 – 905. [15] J. Chen, A. Prodić, R.W. Erickson, D. Maksimović, “Predictive digital current programmed
control,” IEEE Transactions on Power Electronics, vol. 18, pp.411 – 419, Jan. 2003.
CHAPTER 3. DYNAMIC EFFICIENCY OPTIMIZATION FOR MULTI-PHASE CONVERTERS 45
[16] S. Chattopadhyay, S. Das, “A digital current-mode control technique for DC-DC
converters,” IEEE Transactions on Power Electronics, vol. 21, pp.1718 – 1726, Nov. 2006. [17] R.W. Erickson and D. Maksimović, Fundamentals of Power Electronics, 2nd edition.
Boston, MA: Kluwer 2000. [18] Y. Kaiwei, “High-frequency and high-performance VRM design for the next generations of
processors,” Ph.D. thesis, Virginia Polytechnic Institute and State University, April 2004. [19] Y. Kaiwei, Q. Yang, X. Ming, F.C. Lee, F.C. Lee, “A novel winding-coupled buck
converter for high-frequency, high-step-down DC-DC conversion,” IEEE Transactions on Power Electronics, vol. 21, pp.1718 – 1726, Nov. 2006.
[20] “PIP212-12M data sheet,” NXP Semiconductors, Eindhoven, Netherlands. [21] C. Deisch, “Simple switching control method changes power converter into a current
source,” in Proc. IEEE Power Electronics Specialist Conf., 1978, pp. 300 – 306. [22] A. Peterchev, S. Sanders, “Quantization resolution and limit cycling in digital controlled
PWM converters,” in Proc. IEEE Power Electronics Specialists Conference, vol. 2, 2001, pp. 465–471.
[23] O. Trescases, Z. Lukić, W. T. Ng, and A. Prodić, “A low-power mixed- signal current-
mode DC-DC converter using a one-bit Delta-Sigma DAC”, in Proc. IEEE Applied Power Electronics Conf., 2006, pp. 700 - 704.
[24] A. Parayandeh, A. Prodić, “Programmable analog-to-digital converter for low-power DC–
DC SMPS,” IEEE Transactions on Power Electronics, vol. 23, pp.500 – 505, Jan. 2008. [25] “AN-6005 Synchronous buck MOSFET loss calculations with Excel model,” Fairchild
Semiconductors, CA, USA, www.fairchildsemi.com/collateral/AN-6005.zip
46
Chapter 4 Reconfigurable Digital Controllers with Multi-Parameter Estimation
4.1 Introduction Power management systems used for low-power electronic devices require dedicated controller
circuits that provide protection from overload conditions [1], increase energy efficiency through
multi-mode operation [2,3] and obtain fast dynamic response [4]-[18]. For multi-phase
converters, controllers are also needed to ensure proper current sharing [19]-[25] between the
converter phases. Even if all phases are comprised of the same components, mismatches in their
actual values can result in serious problems. Some of the phases could take on significantly
larger currents than others, resulting in current-stress related system failures [1] due to
overheating and uneven component stress. To implement these critical features, actual converter
parameters need to be identified [26]-[28] and inductor currents need to be measured and
actively regulated to maintain safe operation.
Generally, the current measurement methods for dc-dc converters can be categorized into
voltage drop and observer based methods. In voltage drop based methods, a current passing
through a sense-resistor or a MOSFET is extracted from the voltage drop it causes [29]-[33]. The
observer-based systems usually estimate current from the voltage across the power stage inductor
[34,35].
In most cases, the existing methods are not well-suited for integration with the rapidly
emerging digital controllers of switch-mode power supplies (SMPS) for battery-powered
electronic devices, where the overall size, the system cost, and the overall efficiency are among
the main concerns [2,3]. The voltage drop methods either decrease efficiency of the converter
[29] or require a wide-bandwidth amplifier, which is very challenging to implement in the latest
CMOS digital processes. This is due to very limited supply voltages of standard digital circuits
(often below 1 V), at which traditional analog architectures cannot be used. Hence, bulkier and
less reliable multi-chip solutions are needed for such architectures, requiring a sensing circuit
and controller implemented in different IC technologies. On the other hand, the observer based
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 47
methods suffer from limited accuracy [36]. The current estimation relies on prior knowledge of
the inductance and equivalent series resistance values [35,36], which depend on operating
conditions and change under external influences.
In addition to the current sensing methods described above, temperature monitoring of
switching components can be used to further improve system reliability. Dedicated temperature
sensors [37,38] can be placed next to the power switches as parts of the over temperature
protection system. They send information to the thermal protection circuit of the controller,
which, in the case of overheating, shuts down the SMPS. Again, the implementation of such a
system requires a multi-chip solution and is therefore unsuitable for low-power systems. Hence,
though very useful, the temperature protection of switching components is seldom applied.
The first goal of this chapter is to introduce a combined digital current and temperature
estimator, shown in Fig. 4.1.a), which is suitable for single-chip integration with modern low-
power digital controllers regulating the operation of single-phase and multi-phase converters.
The self-tuning current estimator, from Fig. 4.1.a), utilizes the flexibility of digital
implementation to compensate for the changes in the inductor parameters and achieve accurate
Figure 4.1: a) A digitally-controlled buck converter with the self-tuning current estimator and remote temperature monitoring system b) A dual-phase buck converter regulated by the non-linear multi-phase digital average current-mode controller based on the multi-phase self-tuning current estimator.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 48
current estimation. In addition to a simple digital IIR filter and a load step circuit, the current
estimator only requires a slow analog to-digital converter for the input voltage measurement.
Therefore, a practical realization of the estimator results in a modest increase in digital controller
complexity. Additionally, from the converter parameters identified during the current estimator
calibration, such as the converter equivalent resistance Req that inherently includes the resistance
of the switching components, the temperature of the switches can be estimated and remotely
monitored in real-time to prevent system failures due to overheating, as shown in Fig. 4.1.a).
Both the current estimator and remote temperature monitoring system are also fully
implementable in the latest digital CMOS technologies allowing for a simple integration with the
upcoming digital controllers.
The second goal of this chapter is to propose a non-linear average current-mode digital
controller, shown in Fig. 4.1.b) that utilizes information about the estimated phase currents and
identified converter parameters (phase inductances and output capacitance) to achieve fast
transient response and dynamic current sharing. Recent digital and analog controllers [7], [12]-
[16], based on a capacitor charge-balance principle [7], are designed to provide superior time-
optimal response of single-phase converters. Unfortunately, their control actions and output
voltage response are sensitive to component tolerances and require both fast and accurate
detection of the voltage valley point. To effectively resolve previous implementation challenges,
the new two-step transient algorithm is introduced. The algorithm takes into account component
mismatches, eliminates the need for fast valley-point detection, and provides a bumpless
transition between two steady states by also considering the inductor current ripple. Uneven
aging and thermal stress of converter phases due the parasitic parameter mismatches are
prevented by dynamically adjusting the current distribution ratio based on the identified
information about phase equivalent resistances Req. As a result, dominant phase conduction
losses at heavy load and heat dissipation are dynamically equalized between all phases.
In the following section the basics of the inductor voltage based current estimation are briefly
reviewed and the principle of the operation of the self-tuning digital current estimator is
explained.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 49
4.2 Principle of Current-Estimator Operation
Figures 4.2.a) and 4.2.b) explain the principle of operation of the conventional analog current
estimator [35] and the self-tuning digital system introduced in this paper, respectively. In the
analog implementation of Fig. 2.a), the inductor current iL(t) is extracted by placing an R-C filter
in parallel with the power stage inductor and measuring the filter’s capacitor voltage vsense(t). The
relationship between the capacitor voltage and the inductor current is given by the following
transfer function:
( ) ( ) ( ) ,11
1
1
f
LLL
ff
LLLsense s
sRsICRs
RLs
RsIsVττ⋅+⋅+
⋅⋅=⋅+
⋅+⋅⋅= (4.1)
where L and RL are the inductance and its equivalent series resistance values, respectively, and Rf
and Cf are the values of the filter components. When the filter parameters are selected so that τf
= Rf ⋅ Cf = L/RL = τL, the capacitor voltage becomes an undistorted scaled version of the inductor
current (the zero and pole cancel each other). This allows the inductor current to be reconstructed
from the capacitor voltage measurements. As mentioned earlier, the main drawback of this
method is that the inductor parameters are not exactly known and change over time, often
causing large errors in the estimation [36]. To compensate for these variations, an analog filter
Figure 4.2: Current sensing techniques: a) conventional analog implementation b) implementation with a self-tuning digital filter.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 50
with programmable resistive networks is proposed in [39,40] where, in the latter publication, an
on-chip implementation of the filter is shown. Even though the method significantly improves
the estimator accuracy, its implementation still requires a relatively large number of analog
components and the sensed current is still an analog signal, making it less suitable for integration
with digital controllers in low-power SMPS.
In the new estimator of Fig. 4.2.b) the analog filter is replaced with a fully-digital and tunable
equivalent. In this implementation, the voltage across the inductor is converted into a digital
value vL[n] and then processed in the digital domain, to extract the output value isense[n], which is
directly proportional to the inductor current.
By manipulating (4.1) and applying a bilinear transformation, the simple difference equation
suitable for the practical digital filter implementation can be derived:
{ },])1[][(]1[1][][ 21 −+⋅+−⋅⋅⋅== nvnvcniRcRR
nvni LLsenseLLL
sensesense (4.2)
where c1 and c2 are filter coefficients:
),21/()12(1sLsL TR
LTR
Lc ⋅+−⋅= (4.3)
,)21( 12
−⋅+=sLTR
Lc (4.4)
and Ts is the filter sampling rate. The estimator adjusts the filter gain factor 1/RL from (4.2) and
coefficients c1 and c2 through a self-calibrating process. This is obtained with the help of a test
current sink connected at the converter output, as shown in Figs. 4.1 and 4.3. Periodically, the
sink implemented with a known resistor and a small switch connected parallel to the load, turns
on for a short time. Then, based on the response of the filter, the Gain/τ Calibration Logic block
adjusts the filter gain and coefficients so that the increase in isense[n] corresponds to the exact
increase in the load current. The calibration technique introduced here is similar to that in [40]
where a known test current is injected into the inductor during the converter start-up phase for
the purpose of calibrating an analog filter for current estimation. However, the limitation
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 51
Figure 4.3: Test current sink circuit used for the filter calibration.
of this method is that it cannot be used during regular converter operation because it requires
both converter switches to be turned off during the filter calibration phase. Since the series
inductor resistance RL and inductance L dynamically change, due to variations of converter
operating conditions (e.g. output load current or temperature), the accuracy of the current
estimation might be compromised. Since the current sink of Fig. 4.3 does not require any change
in converter operation, the method presented here can be used during normal converter operation
and the calibration can be performed regularly.
4.3 Practical Implementation of the Current Estimator
Even though the principle of operation of the self-tuning digital estimator is relatively simple, its
practical implementation is not trivial. It potentially requires a very fast ADC, with a sampling
rate significantly higher than the switching frequency, as well as an equally fast processor for the
filter implementation. These components threaten to make the estimator impractical for
cost-sensitive, low-power applications.
The precision and speed of the estimator depend on the accuracy of the measurement of the
average inductor voltage value. Even a small inaccuracy in this measurement can cause a large
estimation error. To obtain fast estimation, accurate measurement of the inductor voltage over
one switching cycle is required. This could be done with an ADC whose sampling rate is much
higher than the switching frequency. The need for a very high sampling rate converter is
illustrated in Fig. 4.4. In this case, the average value of the inductor voltage can be calculated by
summing the sampled voltage values and dividing the result by the number of samples taken
during one switching cycle. However, as seen in Fig. 4.4, the accuracy of this approach strongly
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 52
depends on the number of samples taken (i.e. the speed of the ADC), especially if the samples
are not perfectly aligned with the inductor voltage transition point.
Figure 4.4: Signals of a filter implemented with an over-sampling ADC.
To alleviate this dependency, the input voltage of the power stage vg(t) is sampled at a rate
lower than the switching frequency and the average value of the inductor voltage is calculated as:
],[][][][ nvnvndnv outinaveL −⋅=− (4.5)
where d[n] is the DPWM’s control variable and vout[n] is the converter output voltage, both of
which are readily available in the control loop of Fig. 4.1. The vout[n] value is provided by the
already existing ADC of the voltage control loop and the duty ratio is provided by the digital PID
compensator. A lower sampling rate is possible because in targeted battery-powered applications
the input voltage often changes in a very slow fashion. It should be noted that the complete
implementation of the new estimator, including ADC-s, is possible in standard CMOS processes.
Recent publications [2], [3], [41], [42] show application-specific ADCs for SMPS that are
implemented in the latest low-voltage CMOS technologies.
4.3.1 Filter Architecture and Self-Calibration
The calculation of the average voltage described in the previous subsection reduces hardware
requirements but concurrently affects the estimation accuracy. The actual average inductor
voltage might differ from (4.5), due to the action of non-overlapping, i.e. dead-time circuit, and
other parasitic effects. To compensate for this effect, as well as for the previously mentioned
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 53
variations in the inductor values, a current sink and calibration logic (Fig. 4.1) are used to tune
the parameters of the infinite impulse response (IIR) digital filter shown in detail in Fig. 4.5. The
calibration of the filter coefficients described with (4.2) and other parameters is performed in
three phases.
In the first phase, a known load current step is introduced by enabling the current sink and the
accurate value of the filter gain 1/RL is found from the variation in the estimated inductor current.
In the second phase, the current sink is disabled and the time constant τL = L/RL, determining
coefficients c1 and c2, is calculated from the estimator output overshoot/undershoot during the
load step-down transient. Finally, in the third phase, any offset in the estimated current due to the
action of the dead-time circuitry is removed by temporarily changing the switching frequency
and monitoring the response of the estimator. A more detailed description of the calibration
procedure is given in the following subsections.
Figure 4.5: The architecture of the tunable IIR filter used in the current estimator.
4.3.1.1 Filter Gain Calibration Procedure
The Calibration Logic block, shown in Fig. 4.1, periodically performs the calibration
procedure. The correct value of filter gain 1/RL is determined from the difference between two
steady state current values, estimated before and after a load step is applied as shown in Fig. 4.6.
The initial steady state is detected by monitoring the error signal e[n] and at the time instant A
(Fig. 4.6), the current before the transient is estimated as I1=isense[n] and stored in a register. After
a step ΔI is introduced and steady state is reached again, the new current I2 = isense[n] is found and
the difference,
ΔIm=I2−I1, (4.6)
is calculated. This value is then compared to the actual value of the current step and the actual
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 54
Figure 4.6: Filter gain calibration procedure: simulated response of the current estimator during output load change for two cases (bottom curve) the initial value of RL is twice the actual value (top curve) after the filter adjustment.
value of RL , named as RL_calibrated , is calculated as:
,__ initalLm
calibratedL RI
IR∆∆
= (4.7)
where RL_inital is the initially set resistance value. The filter gain value is then adjusted as:
.1
_ calibratedLRgainfilter = (4.8)
The value of RL_calibrated includes not only the actual inductor DCR resistance, but also all
parasitic resistances that are in the inductor current path between the input voltage and output
voltage sampling instance: parasitic drain-source on-resistances of switching devices and PCB
trace resistances. This is illustrated in Fig. 4.7.b) showing the steady-state dc equivalent circuit
derived from the converter shown in Fig. 4.7.a). From Fig. 4.7.b), based on Ohm’s law, the
correct filter gain that, in steady state, multiplies the average inductor voltage vL-
ave[n]=d[n]∙vin[n]-vout[n] to obtain the inductor current, is then:
[ ] ,)1(][
1
_2_1 tracesondsondsL RRndRndRgainfilter
+⋅−+⋅+= (4.9)
which is also calculated based on (4.8) as 1/RL_calibrated.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 55
Figure 4.7: The buck converter (a) and its steady-state dc equivalent circuit Req (b) used for current estimation.
4.3.1.2 Filter Time Constant Calibration Procedure
The uncertainties of an actual inductor value L and its parasitic series resistance RL affect the
time constant τf (4.1) and therefore the time response of the filter. This effect is demonstrated in
Fig. 4.8 showing the actual and estimated inductor currents during a load step for different time
constants: the actual time constant τL, and 50% of this value. It can be seen that the estimated
current accurately follows iL(t) only when filter coefficients for the actual inductor value L and
RL are properly set. In other cases, the estimated current exhibits either undershoot or overshoot
as illustrated in Fig. 4.8. The calibration of τf is performed during the transient, at the output
voltage peak point (time instant B in Fig. 4.8), where the inductor current is equal to that of the
load current [12]. At this time instant, the estimated current is compared with the expected value
I1-ΔI and the difference, ΔIpeak, is calculated:
(4.10)
Based on ΔIpeak, the initially selected filter time constant τf, and the measured time interval ΔTpeak
between the moment when the sink circuit is disabled and the peak point is detected, the actual
inductor time constant τL is obtained:
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 56
(4.11)
For instance, for the simulation result shown in Fig. 4.8, τL is selected to be equal to 2τf and the
filter response exhibits a large overshoot when the sink circuit is disabled. By using the
parameters ΔIpeak=0.68 A and ΔTpeak=22 μs, dynamically obtained from the estimator response,
for the τf=32.6 μs and sink step size ΔI of 1 A, the inductor time constant τL according to (4.11)
is calculated to be equal to 2.02τf. As a result, it is possible to adjust the new filter time constant
τf based on the calculated τL from a single action of the sink calibration circuit. Once the correct
τL =L/RL is known, filter coefficients c1 and c2 are adjusted according to (4.3) and (4.4)
respectively.
The filter time constant tuning procedure presented here is significantly faster than previous
iterative-based procedures demonstrated in [39], [40], [43]. This allows the current estimator to
be utilized as a reliable solution for over-current protection and monitoring even if the power
stage components have large tolerances. The detailed derivation of (4.11) is given in Appendix
A.
Figure 4.8: Calibration of the time constant: simulated response of the current estimator during output load change between 2 A and 2.5A; (bottom) for τf=0.5τL; (top) for τf=τL.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 57
4.3.1.3 Offset Calibration Procedure
Due to the operation of the dead-time circuit and unbalanced timing delays of gate driver
circuitry driving parasitic capacitances of power MOSFETs, the duty-ratio value of non-
overlapping control signals is different than the duty ratio command d[n] calculated by the PID
compensator from Fig. 4.1. Although the output voltage regulation is not affected since the
compensator automatically adjusts d[n] to compensate for Δd introduced by the dead-time
circuit, the current estimator produces an incorrect estimate of the inductor current as shown in
Fig. 4.9. The difference between the current estimation and inductor current is caused by the
incorrectly calculated average inductor voltage vL-ave[n] from d[n] according to (4.5). From Fig.
4.9 it can also be observed that the actual inductor voltage obtained as a difference of the voltage
at the switching node vLx(t) and the output voltage vout(t) does not have an ideal square-wave
shape shown in Fig. 4.4. The presence of voltage ringing at vLx(t), caused by converter parasitics,
influences the actual average inductor voltage calculated by the estimator from (4.5).
For instance, in steady state, with a duty ratio mismatch Δd added to the true duty ratio value,
the estimated current becomes equal to:
.][][)][(][][L
outintrue
L
aveLsense R
nvnvdndR
nvni −∆+== − (4.12)
If we rearrange (4.12), an offset in the estimated current becomes proportional to the duty
Figure 4.9: Offset in the estimated current isense[n] caused by the operation of the dead-time circuit and converter.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 58
ratio mismatch Δd:
.][][][][][L
in
L
outintrue
sense Rnvd
Rnvnvndni ⋅∆+
−⋅= (4.13)
To eliminate the offset the following procedure is applied. By monitoring the error signal e[n],
the converter steady state is first detected and current sample I1 of the estimated current is taken.
In the next step, the switching frequency fsw of the DPWM is increased by k-times ( fsw’ = k∙ fsw )
and another sample I2 is taken once the steady state is reached again. Since the duty ratio
mismatch Δd is proportional to the switching frequency:
,swsw
ftT
td ⋅∆=∆
=∆ (4.14)
where Δt is a constant time interval caused by the dead-time circuit, from (4.13) and (4.14), I2
becomes larger than I1. Based on the difference between I2 and I1, the current offset from (4.13)
and (4.14) can be calculated as:
.1
][ 12
−−
=⋅∆
=k
IIR
nvdoffsetL
in (4.15)
In applications, where the input voltage may change significantly between two offset
calibrations, a sample of vin[n] (i.e. Vin_offset) can be also taken during the calibration and then
used to additionally scale the offset value by a factor vin[n]/ Vin_offset . This scaling dynamically
compensates for the offset deviation proportional to vin[n] as predicted by (4.13) and (4.15). The
estimated current is then corrected by subtracting the final offset value in the digital filter
architecture as shown in Fig. 4.5.
4.3.2 Steady-State Current Estimator Architecture
Knowledge about the inductor current in steady state is sufficient for significantly improving
system performance in many applications. For instance, to extend the battery life of portable
systems, multimode operation can be performed by monitoring the steady-state inductor current.
Examples of this include on-line switching between pulse-width and pulse-frequency modes of
operation [2], [44], dynamic sizing of power switches [45], and gate-drive circuit adjustments
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 59
[45]. For these cases, several parts of the current estimator system architecture of Fig. 4.1 can be
further simplified to obtain a steady-state current estimator [46,47] reducing system hardware
requirements and cost. For example, the programmable digital IIR filter calculating current
estimate isense[n] from Fig. 4.5 can be optimized for operation where only the steady-state current
is required. Consequently, the low-pass filtering logic shaping the response of the estimated
current during load transients is now removed. The average inductor voltage vL-ave[n] is fed
directly to the filter gain multiplication and offset adjustment. Since filter coefficients c1 and c2
are not used anymore, externally programmable look-up tables that keep their pre-calculated
values are also eliminated. Also, the calibration logic can be simplified by removing the filter
time-constant procedure that selects the proper set of filter coefficients.
Figure 4.10: The implementation of the steady-state current estimator.
4.4 Principle of Temperature Monitoring Operation
In the previous section, it is demonstrated that resistance RL_calibrated obtained during the gain
calibration procedure for the current estimator is represented by a sum of all parasitic resistances
in the inductor current path between the input voltage and output voltage sampling instance:
[ ] ..)1(][ _2_1_ tracesondsondsLcalibratedL RRndRndRR +⋅−+⋅+= (4.16)
According to (4.16), the parasitic on-resistances Rds1_on and Rds2_on of the converter power
switches are dominant parts of RL_calibrated. In addition to its original purpose of providing
accurate current estimation, the extracted value of RL_calibrated can now be used for monitoring the
temperature of the power switches and for overheating protection. As illustrated in Fig.11,
RL_calibrated depends on the temperature, meaning that, for a given operating condition, the
temperature of the switching components can be found from RL_calibrated and the load value.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 60
As it will be shown later, a fairly accurate estimate of the temperature can be obtained by
using a look up table with pre-stored temperatures for a range of RL_calibrated and the load current
values. In Fig. 4.1, the look-up table is part of the temperature monitoring block. Overly high
temperature in the components causes RL_calibrated to exceed a certain threshold value Rthresh, at
which point the block shuts down the switches and also sends an external overheat signal.
Figure 4.11: Change of RL_calibrated due to the ambient temperature for different output load current conditions.
4.5 Inductor and Output Capacitor Identification
The system shown in Fig. 4.1.a), with little additional hardware, is also capable of providing the
controller with continuous information about key converter parameters: the sizes of the inductor
and output capacitor. These parameters can be further utilized to optimize the controller response
and implement power supply health monitoring [48]. To reduce the required hardware for the L
and C parameter identification, parameters obtained during the filter calibration are simply
reused for this purpose.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 61
4.5.1 Inductor Identification
The inductor value L is estimated from the inductor time constant τL and resistance RL_calibrated.
Both τL and RL_calibrated are already found during the filter gain and time constant calibration
procedure described in Section 4.3. The inductance value L is then simply calculated from their
product:
._ calibratedLL RL ⋅=τ (4.17)
4.5.2 Output Capacitor Identification
The actual size of the output capacitor is estimated during the filter time constant calibration
when the output load current is stepped down by disabling the current sink as shown in Fig. 4.8.
The size of the output voltage deviation ΔVpeak caused by the sink action is obtained from the
voltage error signal e[n] at the peak point:
._ ADCqpeakpeak VeV ∆⋅=∆ (4.18)
where ΔVq_ADC is the quantization step size of the output ADC. Additional electric charge ΔQ
injected into the output capacitor C from the current difference between the inductor and load
current is proportional to the generated output voltage deviation ΔVpeak:
.peakVCQ ∆⋅=∆ (4.19)
Alternatively, if we approximate that the inductor current iL(t) linearly decreases with the slope
ΔI/ΔTpeak as shown in Fig. 4.8, the charge ΔQ during ΔTpeak can be expressed in terms of the sink
step size ΔI and time interval ΔTpeak as:
.21
peakTIQ ∆⋅∆=∆ (4.20)
By combining (4.19) and (4.20), the capacitor value C is estimated as:
peak
peak
VTI
C∆
∆⋅∆=
2, (4.21)
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 62
under the assumption that its ESR value is small. For example, for the waveform shown in Fig.
4.8, the output capacitor used for simulation is 200 μF. According to the waveform parameters
ΔTpeak = 22 μs and ΔVpeak = 54 mV for a sink step size ΔI of 1 A, the estimated capacitance is
equal to 203.7 μF.
4.6 Oversampled Non-Linear Average Current-Mode Controller
for Multi-Phase Converters
Unlike the voltage-mode controller from Fig. 4.1.a), the non-linear average current-mode
controller regulates both the output voltage and phase inductor currents by generating references
for the phase currents. As shown in Fig. 4.1.b), the new architecture is fully-digital, except for
the analog-to-digital converters (ADC) and the current sink. The multiple current-sensing circuits
are replaced with the multi-phase current estimator and current sink, allowing for significant cost
and size reduction of the multi-phase converter. Tight voltage regulation, fast transient response
and dynamic current sharing are obtained by switching between two modes of operation used for
steady-state and during large load transients. The new system is comprised of a PI compensator,
current sharing logic, current-compensator loops based on the multi-phase current estimator, and
a transient compensator. To enable rapid detection of sudden load disturbances and produce a
fast reaction of the controller, the output voltage ADC samples eight times per regular switching
cycle. The operation of the controller and its key blocks are described in the following
subsections.
4.6.1 Steady-State Mode
For light-load changes and in steady state, the controller operates as follows. Based on the error
between the output voltage and its reference, e[n], a PI compensator creates itot[n], a digital value
proportional to the total current of all phases, i.e. to the load current. The value itot[n], is then
passed to the current sharing logic that sets digital references irefi[n] for the currents of all phases
(i=1,…, N). To calculate the phase duty-ratio control signal di[n] such that the average of the
phase currents follows the reference irefi[n], the current compensators apply an average-current
dead-beat algorithm presented in [4], [49]:
[ ] [ ] [ ]( )ninikDnd senseirefiii −⋅+= , (4.22)
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 63
where D is the nominal steady-state duty ratio value, obtained as a ratio of the output voltage
reference Vref and input voltage vin[n]. The gain coefficient ki is proportional to the estimated
phase inductance Li and is dynamically adjusted as vin[n] changes according to:
swrefin
ii f
VnvLk ⋅−
⋅=][
5.0 . (4.23)
4.6.2 Multi-Phase Current Estimator Tuning and Phase Identification
The calibration process used for the single-phase topologies cannot be directly applied for multi-
phase converters regulated by the voltage-mode controllers. For the single-phase converter, the
load step introduced by the current sink must be equal to the inductor current. In multi-phase
converters, this is not the case. The current sink step can be shared between the phases in many
different ways, depending on the mismatch in power stage component values.
To solve this problem, the average current-mode controller is used and a phase-by-phase
calibration process, based on “freezing” the current of all phases but one, is implemented. As a
result only the current in the active phase increases and the increment is equal to that of the test
current sink allowing for proper current estimator calibration, as described in Section 4.3, for that
specific phase and accurate identification of parameters such as phase equivalent resistance Reqi,
where i =1,…,N.
The inherent capability of the current-mode controller from Fig. 4.1.b) to freeze the average
phase currents presents the possibility for a simplified capacitor/inductor identification algorithm
that does not require peak point detection. To eliminate errors in the identified parameters due to
periodic noise introduced by interleaved switching of the converter phases, the output capacitor
and inductances are also estimated based on a difference of two voltage samples. The samples
are taken at identical time instances during two switching cycles as illustrated in Fig. 4.12 so that
the common noise is subtracted. In the first step, the current references are frozen and the current
sink is disabled causing the output voltage to increase at a rate inversely proportional to the
output capacitor value. Shortly after the sink is disabled, the first voltage sample is taken. The
introduced delay eliminates the effect of the capacitor ESR on the capacitor identification. After
n switching cycles Tsw (e.g. n=2), the second voltage sample is then obtained. From the
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 64
accumulated voltage difference ΔV1 between two samples, the output capacitor is now estimated
as:
1VTnI
C sw
∆⋅⋅∆
= , (4.24)
where ΔI is the current sink current. In the second step, the current reference is reduced in the
phase where inductor value estimation is desired. This causes the inductor current to decrease.
After a delay of one switching cycle, the third sample is taken, and from the difference ΔV2 the
phase inductance is identified as:
sw
outswi TIVC
VTL⋅∆+∆⋅
⋅⋅=
2
22. (4.25)
Figure 4.12: Differential output capacitor and phase inductance identification.
4.6.3 Conduction Loss-Based Current Sharing Scheme
The output load current is often equally shared [19,20] between converter phases consisting of
components with identical nominal values and current ratings. Due to the enforced equal current
sharing, parasitic resistance mismatches of power switches and board traces between phases
produce higher conduction power losses in one of the phases. For instance, for modern high-
current integrated converters [50,51] supplying up to 35 A of current per phase, a small
mismatch of 1 mΩ generates more than 1 W extra power loss, or between 5% and 10% of total
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 65
conduction loss per phase at full load. The additional power loss generates more heat and
increases switch temperature [50], as shown in Fig. 4.13, leading to faster aging of components
and premature failure of one of the phases. To eliminate the temperature mismatch, the
controllers that adjust phase currents based on the feedback from external temperature sensors
mounted on the top of the power switches, were introduced in [52,53]. However, in practice,
such controllers are still not widely accepted in high-volume, cost-sensitive low-power
applications due to the increased component count, size, and circuit complexity.
To resolve this problem and eliminate the need for external temperature sensors, the controller
from Fig. 4.1.b) balances phase conduction losses based on the estimated phase resistances Reqi:
2222
211 LNeqNLeqLeq IRIRIR ⋅==⋅=⋅ , (4.27)
obtained during the calibration of the multi-phase current estimator. According to (4.27), for a
two-phase converter, shown in Fig. 4.1.b), the desired current sharing ratio is equal to:
2
1
1
2
eq
eq
ref
ref
RR
ii
ratio == . (4.28)
Figure 4.13: Mismatch in phase equivalent resistances generates unequal thermal stress on power switches.
From the resistance-based current ratio, the current-sharing logic from Fig. 4.1.b), splits total
current command itot[n] to produce current references iref1[n] and iref2[n] as:
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 66
[ ] [ ]niratio
ni totref ⋅+
=1
11 , (4.29)
[ ] ][][ 12 ninini reftotref −= . (4.30)
4.6.4 Transient Mode
The transient compensator block, shown in Fig. 4.1.b), detects large load current changes ΔIload
and dynamically overrides the operation of the conventional PI compensator to provide much
faster transient response and smaller output voltage deviation. It processes error values e[n] eight
times per switching cycle, which is four times faster than the PI compensator. From the error
difference between two consecutive samples e[n-1] and e[n], it calculates the slope of the output
voltage ΔVslope and accordingly estimates ΔIload:
sample
slopeload T
VCI
∆
∆⋅=∆ , (4.31)
where the actual value of the output capacitor C is obtained during the current estimator
calibration. If ΔIload surpasses a threshold (i.e. 1/3 of the maximum load current Iload), the
transient compensator temporarily disables the PI compensator, enters the transient mode and
executes a two-step control algorithm illustrated in Fig. 4.14 for a two-phase buck converter. The
load change threshold is set to prevent triggering of the transient compensator by the inductor
current ripple, switching noise, and more importantly to avoid frequent switch-on/off actions of
the power stage for light load changes that would decrease the power stage efficiency.
In the first step, depending on the sign of ΔIload the transient compensator decides whether to
turn on or turn off all phases in order to equalize the sum of average phase currents with the load
current. For a light-to-heavy load step, +ΔIload, the turn-on time ton is proportional to ΔIload and an
equivalent inductance Leq= L1 || L2 || … || LN of all phases now connected in parallel:
,loadoutin
eqon I
vvL
t ∆⋅−
= (4.32)
For a heavy-to-light load step, −ΔIload, the turn-off time is calculated as:
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 67
).( loadout
eqoff I
vL
t ∆−⋅= (4.33)
At the moment when all phases are switched on/off, the DPWM carrier value, used for the
synchronized generation of all pulse-width modulated signals, is frozen until either ton or toff are
finished. Once unfrozen, the original phase switching sequence resumes exactly where it was
interrupted as shown in Fig. 4.14. The inductor currents are brought to an average level,
accommodating the load current and the output voltage deviation is rectified. Before the first step
of the transient algorithm is fully completed, the transient compensator first updates itot[n] of the
PI compensator by adding an increment of ± ΔIload to its integral portion. The estimated average
phase currents isensei[n] are also modified by adding the transient increments Δvsensei to the
registers holding the sensed voltage vsensei[n]:
i
eqloadeqisensei L
LNI
Rv ⋅∆±
⋅=∆ . (4.34)
Once the voltage deviation is blocked, the transient compensator performs the second step that
quickly brings the output voltage back to steady state. The compensator now takes a voltage
sample, intended for the PI compensator, and measures the deviation ΔVdev at that point as shown
in Fig. 4.14. The total capacitor charge that needs to be recovered to reach the new steady state is
equal to:
devdev VCQ ∆⋅=∆ . (4.35)
To compensate for ΔQdev and achieve a bumpless transition when the PI compensator is
reactivated, the transient compensator increases the duty ratio of all phases to D+Δdi during the
first switching cycle. In the following cycle, the duty cycles are dropped to D−Δdi. As a result,
an additional charge, ΔQi, is injected by each phase but the phase average currents are positioned
properly for the PI compensator to resume as shown in Fig. 4.14. The injected charge by each
phase is proportional to Δdi:
2swi
i
ini Td
LvQ ⋅∆⋅=∆ . (4.36)
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 68
If ΔQdev is now shared between N phases, the required Δdi for each phase is equal to:
in
deviswi v
VN
CLfd ∆⋅
⋅⋅=∆ 2 . (4.37)
Figure 4.14: Transient mode operation of the non-linear average current-mode controller.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 69
To generate increments ±Δdi with minimal additional hardware, the current-loop
compensators are utilized. They are produced by changing the current references by ± Δirefi. The
phase injected charge ΔQi can be expressed in terms of Δirefi from (4.22) and (4.36) as:
2swrefi
i
ini Tik
LvQ ⋅∆⋅⋅=∆ . (4.38)
Finally, by substituting (4.23), and (4.35) to (4.38), Δirefi for each phase is equal to:
devswrefi VCDfN
i ∆⋅⋅−⋅⋅
=∆ )1(2
. (4.39)
If necessary, to avoid current saturation of the inductors, the introduced current reference step
Δirefi can be reduced by extending it across several switching cycles ncycles as:
reficycles
refi in
i ∆⋅
=∆
1' . (4.40)
Once the charge ΔQdev is fully compensated, the transient compensator reactivates the PI
compensator which then continues to regulate the output voltage until the next large load
transient occurs.
4.6.5 Hardware Optimization and Controller On-Chip Complexity
To achieve a cost effective on-chip implementation, the controller hardware from Fig. 4.1.b) is
carefully optimized for multi-phase operation. Since all phase control signals are interleaved, the
current estimator is also time multiplexed to reduce computation resources (logic multipliers and
adders). The block diagram of the multi-phase current estimator is shown in Fig. 4.15. The same
approach is applied to the current compensators which are implemented as a single time-
multiplexed current compensator calculating duty cycles intermittently. Finally, to reduce the
number of internal registers used by both blocks and share partial computation results, the
transient compensator and current estimator tuning logic are merged. Table 4.1 shows the
occupied area and number of digital cells for each digital block when implemented in TSMC
0.18-µm CMOS technology. All digital blocks of the controller, shown in Fig. 4.1.b) occupy
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 70
0.43 mm2 of silicon area or equivalently 15,610 digital logic cells.
Figure 4.15: A time-multiplexed N-phase digital current estimator.
Table 4.1: The silicon area and gate count of the multi-phase controller when implemented in TSMC 0.18-µm CMOS process.
Design Block area [mm2] logic cell count
PI compensator 0.051 1767 Current sharing logic 0.017 632 Two-phase current estimator 0.080 2716 Current compensators 0.022 830 Transient compensator & current estimator tuning logic 0.247 8811 Two-phase DPWM (8-bits resolution) 0.021 854
Total (digital blocks) 0.438 15610
4.7 Experimental Systems and Results
An experimental single-phase system was first built based on the diagrams shown in Figs. 4.1.a),
4.3, and 4.5. The power stage is a 15-W, 1.5-V buck converter (nominal output filter component
values are L=1.5 μH and C=200 μF), switching at fsw=500 kHz, with an input voltage range
between 2 V and 6.5 V. The controller, digital filter, calibration logic, temperature and current
monitoring logic are realized with an Altera DE2 FPGA board by Verilog HDL. Two external
ADCs sampling at fsw and fsw/8 are used for output and input voltage measurements respectively.
The resolution of the ADC sampling the output voltage is 4 mV, while the resolution of the ADC
for the input voltage is 16 mV. The test current sink was set to produce a 1 A pulse current,
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 71
which is only 10% of the maximum output current. To visualize the operation of the estimator,
its digital output was sent to a flash digital-to-analog converter (DAC) and the resulting analog
signal was observed.
Figure 4.16 shows the closed loop operation of the controller during load transients between
1.5 A and 4.5 A (ΔI = 3 A) and demonstrates the self-tuning process of the current estimator. In
the first (uncalibrated) phase due to the mismatch in the converter parameters, the filter gain,
time constant τf , and offset are not properly adjusted and an error in the current estimation
occurs (the step is wrongly recognized as a 2.3 A to 4.3 A transition - ΔIest = 2 A). In the second
Figure 4.16: System operation – Ch1: Output converter voltage (200mV/div); Ch2: actual inductor current iL(t) – 2 A/V; Ch3: estimated average current iL[n] – 2 A/V; D0-D1- load step and sink enable signals; Time scale is 500 μs/div.
(calibration) phase, a 1-A test current sink step is introduced and the filter gain, the filter
coefficients defining time constant τf, and offset are tuned accordingly. The third (calibrated)
phase shows repeated load transient, where the average current is estimated accurately both in
steady state and during the transient, verifying the effectiveness of the self-tuning filter and the
estimator operation.
4.7.1 Filter Gain Calibration
To correct the filter gain (34% lower than its correct value) causing the actual inductor current
step of 3 A to be recognized as a 2-A step in the estimated current during the uncalibrated phase
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 72
in Fig. 4.16, the filter gain calibration procedure based on a current sink is applied. Fig. 4.17
shows explicitly the operation of the current estimator during the filter gain calibration when the
current sink is enabled. By monitoring the voltage error signal e[n], the calibration logic detects
the steady state (e[n]=0 for 8 consecutive cycles) before and after the current sink is enabled and
measures the difference ΔIm in the estimated steady-state currents to be 0.66 A. From ΔIm and the
known value of the current sink step size ΔI=1 A, according to (4.7) and (4.8), RL_calibrated is
calculated and the filter gain is therefore updated as shown in Fig. 4.17. As a result, the estimated
current is increased by approximately ΔI/ ΔIm≈1.51 times. If a real load transient occurs during
the calibration, the obtained parameters are rejected and the procedure is repeated again.
Figure 4.17: The filter gain (1/RL_calibrated) calibration procedure – Ch1: Output converter voltage (100 mV/div); Ch2: actual inductor current iL(t) – 2 A/V; Ch3: estimated average current iL[n] – 2 A/V; D0-D1- load step and sink enable signals; Time scale is 20 μs/div.
4.7.2 Filter Time Constant Calibration
Initially selected filter time constant τf = 25.5 μs during the uncalibrated phase is approximately
half of the inductor time constant τL =L/RL_calibrated=1.5 μH/ 30 mΩ =50 μs resulting in a large
overshoot of the estimated current as shown in Fig. 4.16. Shortly after the filter gain is calibrated
by enabling the current sink, the calibration of τf is performed by disabling the current sink
causing the inductor current to drop by the value of the sink step size ΔI = 1 A. The actual tuning
process of the filter time constant τf is demonstrated in Fig. 4.18.a). The calibration logic first
measures the estimated steady-state current I1 before the current sink is disabled. In the next step,
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 73
the sink enable signal is set to zero and due to the closed-loop operation the inductor current and
its estimate start to decrease. Once the calibration logic detects the output voltage peak recovery
point, meaning that the inductor current is equal to the new steady-state inductor current I1-ΔI,
the difference ΔIpeak between the estimated current and I1-ΔI is calculated to be 0.65 A according
to (4.10). At the same time, the time period ΔTpeak between disabling the sink circuit and the
detection of the peak point is captured to be ΔTpeak= 20 μs. Based on the initially selected τf, and
the parameters obtained from the estimator response ΔIpeak for the sink step size of ΔI, the
calibration logic calculates the inductor time constant τL according to (4.11) to be 52 μs. Once
the actual inductor constant is identified, the filter time constant is matched to τL and the
coefficients c1 and c2 are properly adjusted.
Figure 4.18: The filter time calibration procedure: a) τf=0.5τL ; b) τf ≈ τL – Ch1: Output converter voltage (100 mV/div); Ch2: actual inductor current iL(t) – 2 A/V; Ch3: estimated average current iL[n] – 2 A/V; D0-D1- load step and sink enable signals; Time scale is 20 μs/div.
As a result, the estimator now exhibits proper response even during the transient as shown in
Figs. 4.18.b) and 4.16 (during the calibrated phase). From the parameters obtained during the
filter time constant calibration (ΔTpeak= 20 μs and ΔVpeak= 75 mV), the size of the output ceramic
capacitor is estimated to be 133 μF. The estimated capacitor value is 34% lower than its nominal
data sheet value at zero bias voltage. This is caused by the DC bias effect [52], caused by the
output voltage, that reduces the actual capacitance of ceramic capacitors.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 74
4.7.3 Offset Calibration
Even though the filter gain and time constant are now properly adjusted, the current estimator
still exhibits an offset of 2 A between the estimated and the true inductor current as shown in
Fig. 4.19. To compensate for this offset, the calibration logic samples the estimated steady-state
currents before and after increasing the switching frequency by two times (k=2). Based on (4.15),
the estimated offset is calculated by the calibration logic to be 2 A. Shortly after the switching
frequency is reduced back to the nominal value, the offset value is subtracted in the digital IIR
filter and good matching between the estimated and actual inductor currents is obtained as
demonstrated in Fig. 4.19.
Figure 4.19: The filter offset calibration procedure – Ch1: Output converter voltage (100 mV/div); Ch2: actual inductor current iL(t) – 2 A/V; Ch3: estimated average current iL[n] – 2 A/V; Time scale is 20 μs/div
4.7.4 Calibrated Operation
Figs. 4.20.a) and 4.20.b) demonstrate fast operation of the estimator when the gain, time constant
and offset are properly tuned. They compare actual and estimated inductor current during both
light-to-heavy and heavy-to-light load changes between 1.5 A and 4.5 A. As it can be seen, the
average value of the current over one switching cycle is accurately estimated without any
significant delay, allowing the estimator to be used for overload protection and power stage
efficiency optimization.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 75
Figure 4.20: The estimated current during load steps between 1.5 A and 4.5 A– Ch1: Output converter voltage (200 mV/div); Ch2: actual inductor current iL(t) – 2 A/V; Ch3: estimated average current iL[n] – 2 A/V; Time scale is 10 μs/div.
4.7.5 Current Estimation with the Steady-State Current Estimator
The operation of the simple steady-state current estimator based on Fig. 4.10 is experimentally
verified in Fig. 4.21 by varying the output load current between 0.8 A and 5.1 A. In this case, the
estimated current is calculated from the average inductor voltage with a direct multiplication by
the filter gain without filtering with coefficients c1 and c2. As a result, the estimator provides
accurate information about the inductor current only in steady state but its hardware
Figure 4.21: The estimated current with a steady-state current estimator during the load step between 0.8 A and 5.1 A– Ch1: Output converter voltage (200 mV/div); Ch2: actual inductor current iL(t) – 2 A/V; Ch3: estimated average current iL[n] – 2 A/V; Time scale is 50 μs/div.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 76
implementation is much simpler since it does not require time constant calibration.
4.7.6 Temperature Monitoring and Protection
Figs. 4.22.a) and 4.22.b) verify proper operation of the temperature estimator/protection block
from Fig. 4.1.a). To test its operation, the converter power MOSFETs are intentionally heated
up. As it can be seen from Fig. 4.22.a), this results in an increase of RL_calibrated (see Fig. 4.22.b)
above the threshold resistance Rthresh, and the triggering of the overheating protection signal that
shuts down the converter.
Figure 4.22: Thermal monitoring: a) at 45 °C; b) at 105°C – Ch1: Output converter voltage (1 V/div); Ch2: estimated steady-state current isense[n] – 2 A/V; Ch3: estimated RL_calibrated – 1 mΩ/32.5 mV; Ch4: MOSFET temperature – 25 ºC/V; D1-D2- sink enable and overheat signal. Time scale is 200 μs/div.
4.7.7 Overload Protection
Simple overload protection of the converter circuitry can be obtained by comparing the output of
the current estimator with a predefined digital current threshold. Once the estimated current
exceeds the threshold value, to prevent converter damage, it is immediately turned off and the
estimator stops its operation as shown in Fig. 4.23. The output load current is intentionally
increased from 2 A to 7.5 A above the threshold of 7 A. Therefore the overload protection signal
is activated and the converter is rapidly turned off.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 77
Figure 4.23: Overload protection implemented with the current estimator– Ch1: Output converter voltage (1 V/div); Ch2: actual inductor current iL(t) – 2 A/V; Ch3: estimated average current isense[n] – 2 A/V; Time scale is 20 μs/div.
4.7.8 Multi-Phase Operation with the Non-Linear Average Current-Mode
Controller
To verify the operation of the non-linear average current-mode controller, from Fig. 4.1.b), the
single-phase buck is now replaced with a point-of-load, two-phase, 80-W, 12-V-to-1.8-V buck
converter switching at fsw=500 kHz. The nominal phase inductances are 0.325 µH (±10%
tolerances) while the total nominal output capacitance is 800 µF (-20/+50% tolerance). To
accommodate the increased input voltage range (up to 16 V), the effective input ADC resolution
is decreased to 32 mV by a voltage divider (1/8). On the other hand, the sampling rate of the
output voltage ADC is increased to 8 times per switching cycle. The current sink used for the
calibration of the multi-phase current estimator is increased to 4 A (less than 10% of max. load
current) due to the increased output capacitance. Shortly after the system start-up, when the
output voltage reaches steady state, the controller initiates the tuning of the multi-phase current
estimator parameters and identifies the actual phase component values. Fig. 4.24 presents the
tuning procedure applied on the first phase, while the second phase current is “frozen.” Initially,
both the gain and time constant of the current estimator are incorrect. After injecting the step and
performing the multi-phase calibration procedure described in Section 4.6, the parameters are
identified. From Fig. 4.24 it can be observed that the current step of the sink fully excites the
active phase. After, the calibration is performed; the corrective action is taken and the estimated
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 78
current is now properly tuned. The identified output capacitance is 500 µF, which is 37.5% lower
than its nominal value due to the capacitor DC bias effect [54].
Figure 4.24: Current estimator tuning and component identification with the multi-phase converter – Ch1: Output converter voltage (50 mV/div); Ch2: actual phase 1 inductor current iL1(t) – 10 A /V; Ch3: actual phase 2 inductor current iL2(t) – 10 A /V; Ch4: estimated current isense1[n] – 10 A/V; D1 - sink enable signal. Time scale is 20 μs/div.
After the tuning and power-stage identification are completed, the response of the non-linear
multi-phase controller is tested with a large load step (0 A − 45 A) as shown in Fig. 4.25. As
soon as the sharp voltage drop is detected and ΔIload is estimated, the transient compensator first
turns on both phases to block the voltage deviation. It can be noticed that phase inductances are
significantly mismatched (≈20%), since iL1(t) is able to reach iL2(t) at the end of the turn-on
action. The transient compensator now measures the voltage deviation and performs the control
actions based on the change of current references producing duty ratio increments ±Δdi. The
current-loop compensators recognize the mismatch of phase inductances and current undershoot
in the second phase. To compensate they provide a larger initial current step for the second phase
as shown in Fig. 4.25. Once the output voltage reaches the new steady state within 5 μs, the
current compensator regulate inductor currents until they match the current ratio specified by
their equivalent resistances.
Finally, the effectiveness of the conduction loss-based current scheme that equalizes the
thermal stress of converter phases is verified. Initially, equal duty cycles of control signals c1(t)
and c2(t) are enforced to show that phase equivalent resistances are indeed mismatched. As
shown in Fig. 4.26.a), the average phase currents are now unequally distributed based on the
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 79
ratio of Req1 and Req2. Phase 1, taking significantly larger portion of the output load current than
Phase 2, has also much higher operating temperature (ΔT12 = 17.8 °C) as demonstrated in Fig.
4.26.b). Then, the conduction-loss based current sharing scheme is enabled. The load current
Figure 4.25: Transient response of the nonlinear average current-mode controller – Ch1: Output converter voltage (50 mV/div); Ch2: inductor current iL1(t) – 10 A /V; Ch3: inductor current iL2(t) – 10 A /V; Ch4: estimated phase 2 current isense2[n] – 10 A/V; D1-D3- sink enable and control signals. Time scale is 5 μs/div.
Figure 4.26: The effectiveness of the conduction-loss based sharing scheme – a) current sharing with equal duty cycles of control signals c1(t) and c2(t); b) mismatched phase temperatures with equal duty cycles of c1(t) and c2(t); c) conduction-loss based current sharing; d) phase temperatures with the conduction-loss based sharing scheme.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 80
is now distributed between phases based on the square root ratio of Req1 and Req2 (Fig. 4.26.c)) to
equalize the conduction losses of both phases. Consequently, the phase temperatures are now
well balanced (ΔT12 = 1.4 °C) as demonstrated in Fig. 4.26.d).
4.7.9 Accuracy of Current and Temperature Estimation
The accuracy of the current estimation is assessed by changing the load current and comparing it
to the estimated value. Before the accuracy measurements are performed, the estimator is
calibrated only once at 30% of the maximum load current. Fig. 4.27.a) shows that a fairly good
estimate is obtained. For the full load, the relative error of the estimation is less than 5% while
for 90% of the full load it is less than 10%. At lighter load, the error increases due to
quantization effects. If the sink step size is increased from 1 A to 2 A, the error is reduced on
average by 1.3% as illustrated in Fig. 4.27.b). Fig. 4.28 shows results of the temperature
estimation. It can be seen that the absolute error of the temperature estimation is limited to ±7 °C
while the relative error is less than 10%. The precision of this measurement depends on the size
of the look-up tables and the accuracy of the data stored in the estimator look-up tables.
Figure 4.27: a) Estimated inductor current versus the output load current with a 1 A sink step size b) Relative error of the estimated current for two sink step sizes: 1 A and 2 A.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 81
Figure 4.28: Estimated temperature versus sensor temperature.
4.8 Conclusion This chapter introduces a combined self-tunable digital current and temperature estimator and the
non-linear sensorless average current-mode controller with for multi-phase dc-dc converters.
Based on the measurement of the inductor voltage and its processing in the digital domain the
current estimator calculates the average value of the inductor current over one switching cycle.
To compensate for the variations in power stage parameters that currently limit the accuracy of
equivalent analog methods, the estimator automatically extracts the main converter parameters
and self-adjusts its parameters by using a test current sink and a tunable IIR filter. Compared to
previous iterative-based tuning methods, the tuning procedure is much faster since it requires
only a single action of the sink circuit. From the extracted equivalent resistance, the temperature
of the MOSFETs is remotely estimated and continuously monitored. The fast and accurate
operation of the current and temperature estimator is demonstrated on a digitally controlled buck
converter prototype.
The non-linear average mode controller utilizes the identified power stage parameters and
estimated phase currents to provide fast transient response and dynamic current sharing. To
equalize the thermal stress between phases, a conduction-loss based current sharing scheme is
implemented. The operation of the controller is verified with a two-phase point-of-load, 80-W,
buck converter showing the response time under 5 μs and a voltage deviation smaller than 100
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 82
mV for a 45-A load step. The digital blocks of the controller are suitable for an on-chip
implementation since they occupy only 0.43 mm2 of silicon area when synthesized in a CMOS
0.18-μm process.
REFERENCES
[1] H. Peng, D. Maksimović, “Overload protection in digitally controlled DC-DC converters," in Proc. IEEE Power Electronics Specialist Conf., Jun. 2006, pp. 1 – 6.
[2] J.Xiao, A.V. Peterchev, J. Zhang, S.R. Sanders, “A 4-μA quiescent-current dual-mode digitally controlled buck converter IC for cellular phone applications,” IEEE Journal of Solid-State Circuits, vol. 39, pp. 2342–2348, Dec. 2004.
[3] N. Rahman, A. Parayandeh, K. Wang, A. Prodić, “Multimode digital SMPS controller IC
for low-power management,” in Proc. IEEE International Symposium on Circuits and Systems, 2006, pp. 5327 – 5330.
[4] S. Bibian, H. Jin, “High performance predictive dead-beat digital controller for DC power supplies,” IEEE Trans. Power Electron., vol. 17, pp. 420 – 427, May 2002.
[5] Kelvin Ka-Sing Leung, Henry Shu-Hung Chung, “Dynamic hysteresis band control of the buck converter with fast transient response,” IEEE Trans. Circuits Syst. II, vol. 52, pp. 398–402, July 2005.
[6] A. Soto, P. Alou, J.A. Cobos, “Nonlinear digital control breaks bandwidth limitations,” in Proc. IEEE Applied Power Electronics Conf., 2006, pp. 724–730.
[7] G. Feng, E. Meyer, Y.-F. Liu, “A new digital control algorithm to achieve optimal dynamic performance in DC-to-DC converters,” IEEE Trans. Power Electron., vol. 22, pp. 1489–1498, July 2007.
[8] Feng Su, Wing-Hung Ki, Chi-Ying Tsui, “Ultra fast fixed-frequency hysteretic buck converter with maximum charging current control and adaptive delay compensation for dvs applications,” Proc. IEEE Journal of Solid-State Circuits, vol. 43, pp. 815–822, Apr. 2008.
[9] S. Saggini, P. Mattavelli, M. Ghioni, M. Redaelli, “Mixed-signal voltage-mode control for DC-DC converters with inherent analog derivative action,” IEEE Trans. Power Electron.,vol. 23, pp. 1485–1493, May 2008.
[10] S. Saggini, P. Mattavelli, G. Garcea, M. Ghioni, “A mixed-signal synchronous/ asynchronous control for high-frequency DC-DC boost converters,” IEEE Trans. Ind. Electron., vol. 55, pp. 2053–2060, May 2008.
[11] L. Corradini, P. Mattavelli, E. Tedeschi, D. Trevisan, “High-bandwidth multisampled digitally controlled DCDC converters using ripple compensation,” IEEE Trans. Ind. Electron.,vol. 55, pp. 1501–1508, Apr. 2008.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 83
[12] Zhenyu Zhao, A. Prodic, “Continuous-time digital controller for high-frequency DC-DC converters,” IEEE Trans. Power Electron., vol. 23, pp. 564–573, Mar. 2008.
[13] E. Meyer, Zhiliang Zhang, Y.-F. Liu, “An optimal control method for buck converters using a practical capacitor charge balance technique,” IEEE Trans. Power Electron., vol. 23, pp. 1802–1812, July 2008.
[14] V. Yousefzadeh, A. Babazadeh, B. Ramachandran, E. Alarcon, L. Pao, and D. Maksimovic, “Proximate time-optimal digital control for synchronous buck DC-DC converters,” IEEE Trans. Power Electron., vol. 23, pp. 2018–2026, July 2008.
[15] A. Costabeber, L. Corradini, P. Mattavelli, S. Saggini, “Time optimal, parameters-insensitive digital controller for DC-DC buck converters,” in Proc. IEEE Power Electronics Specialist Conf., 2008, pp. 1243–1249.
[16] S. Effler, A. Kelly, M. Halton, T. Kruger, and K. Rinne, “Digital control law using a novel load current estimator principle for improved transient response,” in Proc. IEEE Power Electronics Specialist Conf., 2008, pp. 4585–4589.
[17] L. Corradini, E. Orietti, P. Mattavelli, S. Saggini, “Digital hysteretic voltage-mode control for DC-DC converters based on asynchronous sampling,” IEEE Trans. Power Electron., vol. 24, pp. 201–211, Jan. 2009.
[18] Santa C. Huerta, P. Alou, J. A. Olivier, O. Garcia, J. A. Cobos, A. Abou-Alfotouh, “A very fast control based on hysteresis of the cout current with a frequency loop to operate at constant frequency,” in Proc. IEEE Applied Power Electronics Conf., 2009, pp. 799–805.
[19] B. Tomescu, H.F.Vanlandingham, “Improved large-signal performance of paralleled DC-DC converters current sharing,” IEEE Trans. Power Electron., vol. 14, pp. 573 – 577, May 1999.
[20] Peng Li, B. Lehman, “A design method for paralleling current mode controlled DC-DC converters,” IEEE Trans. Power Electron., vol. 19, pp. 748 – 756, May 2004.
[21] J. Abu-Qahouq, Mao Hong, I. Batarseh, “Multiphase voltage-mode hysteretic controlled DC-DC converter with novel current sharing,” IEEE Trans. Power Electron., vol. 19, pp. 1397 – 1407, Nov 2004.
[22] Jaber A. Abu Qahouq, Lilly Huang, Doug Huard, Allan Hallberg, “Novel current sharing schemes for multiphase converters with digital Controller implementation,” in Proc. IEEE Applied Power Electronics Conf., Feb. 2007, pp. 148 – 156.
[23] Y. Zhang, R. Zane, D. Maksimović, “Current sharing in digitally controlled masterless multi-phase DC-DC Converters,” in Proc. IEEE Power Electronics Specialist Conf., Jun. 2005, pp. 2722 – 2728.
[24] Mao Hong, Liangbin Yao, Caisheng Wang, I. Batarseh, “Analysis of inductor current sharing in nonisolated and isolated multiphase dc-dc Converters,” IEEE Trans. Power Electron., vol. 54, pp. 3379 – 3388, Dec 2007.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 84
[25] V. Choudhary, E. Ledezma, R. Ayyanar, R.M. Button, “Fault tolerant circuit topology and control method for input-series and output-parallel modular DC-DC converters,” IEEE Trans. Power Electron., vol. 23, pp. 402 – 411, Jan 2008.
[26] Zhenyu Zhao, A. Prodić, “Limit-cycle oscillations based auto-tuning system for digitally controlled DC-DC power supplies,” IEEE Trans. Power Electron., vol. 22, pp. 2211–2222, Nov. 2007.
[27] L. Corradini, P. Mattavelli, W. Stefanutti, and S. Saggini, “Simplified model reference-based autotuning for digitally controlled smps,” IEEE Trans. Power Electron., vol. 23, pp. 1956–1963, July 2008.
[28] J. Morroni, R. Zane, D. Maksimović, “Design and implementation of an adaptive tuning system based on desired phase margin for digitally controlled DCDC converters,” IEEE Trans. Power Electron., vol. 24, pp. 559–564, Feb. 2009.
[29] H. Forghani-zadeh, G. Rincón-Mora, “Current sensing techniques for DC-DC converters,”
in Proc. IEEE MWSCAS, Aug. 2002, pp. 577– 580. [30] P. Givelin, M. Bafleur, “On-chip over-current and open-load detection for a power MOS
high-side switch: a CMOS current-source approach,” in Proc. European Conf. Power Electronics and Applications, 1993, pp. 197–200.
[31] S. Yuvarajan, L.Wang, “Power conversion and control using a current-sensing MOSFET,”
in Proc. Midwest Symp. Circuits and Systems (MWSCAS), 1992, pp. 166–169.
[32] J. Chen, J. Su, H. Lin, C. Chang, Y. Lee, T. Chen, H.Wang, K. Chang, P. Lin, “Integrated current sensing circuits suitable for step-down DC-DC converters,” IEE Electron. Letters, pp. 200–201, Feb. 2004.
[33] C. Lee, P. Mok, “A monolithic current-mode CMOS DC-DC converter with on-chip current-sensing technique,” IEEE Journal of Solid-State Circuits, vol. 39, no. 1, pp. 3–14, Jan. 2004.
[34] P. Midya, P. T. Krein, M. F. Greuel, “Sensorless current mode control-an observer-based
technique for DC-DC converters,” IEEE Trans. Power Electron., vol. 16, pp. 522 – 526, Jul. 2001.
[35] E. Dallago, M.Passoni, G. Sassone, “Lossless current sensing in low-voltage high-current
DC/DC modular supplies,” IEEE Trans. Ind. Electron., vol. 47, pp. 1249 – 1252, Dec. 2000.
[36] L. Hua, S. Luo, “Design considerations of time constant mismatch problem for inductor
DCR current sensing method,” in Proc. IEEE Applied Power Electronics Conf., 2006, pp.1368 – 1374.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 85
[37] Data Sheet, MAX 6697, 7-Channel Precision Temperature Monitor, Maxim.
[38] Data Sheet, TMP 100, I2C Temperature Sensor, Texas Instruments.
[39] G. Garcea, S. Saggini, D. Zambotti, and M. Ghioni, “Digital auto-tuning system for inductor current sensing in VRM applications,” in Proc. IEEE Applied Power Electronics Conf., 2006, pp. 493 – 498.
[40] H. P. Forghani-zadeh, G. A. Rincón-Mora, “An accurate, continuous, and lossless self-
learning CMOS current-sensing scheme for inductor-based DC-DC converters,” IEEE Journal of Solid-State Circuits, vol. 42, pp. 665 – 679, Mar. 2007.
[41] Z. Lukić, N. Rahman, A. Prodić, “Multi-bit Σ-∆ PWM digital controller IC for DC–DC converters operating at switching frequencies beyond 10 MHz,” IEEE Trans. Power Electron., vol. 22, pp. 1693-1707, Sept. 2007.
[42] A. Parayandeh, A. Prodić, “Programmable analog-to-digital converter for low-power DC-DC SMPS,” IEEE Trans. Power Electron., vol. 23, pp. 1719-1730, Jan. 2008.
[43] Z. Lukić, Z. Zhao, S M Ahsanuzzaman, A. Prodić, “Self-tuning digital current estimator for low-power switching converters,” in Proc. IEEE Applied Power Electronics Conf., 2008., pp. 529 – 534.
[44] N. Rahman, A. Parayandeh, K. Wang, and A. Prodić, “Multimode digital SMPS controller IC for low-power management,” in Proc. IEEE International Symposium on Circuits and Systems, 2006, pp. 5327 – 5330.
[45] O. Trescases, W. T. Ng, H. Nishio, M. Edo, T. Kawashima, “A digitally controlled DC-DC converter module with a segmented output stage for optimized efficiency,” in Proc. IEEE Power Semiconductor Devices and ICs, 2006, pp. 1 – 4.
[46] A. Prodić, D. Maksimović, “Digital PWM controller and current estimator for a low-power switching converter,” in Proc. IEEE Computers in Power Electronics Conf., 2000, pp.123 – 128.
[47] Z. Lukić, A. Stupar, A. Prodić, D. Goder, “Current estimation and remote temperature monitoring system for low power digitally controlled DC-DC SMPSs," in Proc. IEEE Power Electronics Specialist Conf., Jun. 2008, pp. 1139 – 1143.
[48] J. Morroni, A. Dolgov, R. Zane, D. Maksimović, “Online health monitoring in digitally controlled power converters,” in Proc. IEEE Power Electron. Specialists Conf., 2007, pp. 112 – 118.
CHAPTER 4. RECONFIGURABLE DIGITAL CONTROLLERS WITH MULTI-PARAMETER ESTIMATION 86
[49] J. Chen, A. Prodić, R.W. Erickson, D. Maksimović “Predictive digital current programmed control,” IEEE Trans. Power Electron., vol. 18, no. 1, pp. 411 – 419, Jan 2003.
[50] “PIP212-12M data sheet,” NXP Semiconductors, Eindhoven, Netherlands.
[51] “FDMF8700 data sheet,” Fairchild Semiconductors, San Jose, USA.
[52] C. Nesgaard, M. A. E. Andersen, “Optimized load sharing control by means of thermal-reliability management,” in Proc. IEEE Power Electronics Specialist Conf., 2004, pp. 4901–4906.
[53] K. Rinne, A. Russel, “A power converter,” International Patent, "WO/2009/010476", Jan. 2009.
[54] Technical Note, “Mechanism of DC bias characteristics”, Murata.
87
Chapter 5 Conclusions and Future Work
This thesis presents advanced reconfigurable digital controllers of multi-phase dc-dc converters
utilized for power management systems in low power applications, up to 100 W. The proposed
architectures are suitable on-chip integration and provide practical hardware solutions for a broad
range of implementation issues related to: controller power consumption, dynamic converter
efficiency optimization, current estimation, temperature monitoring, converter parameter
estimation, and combined fast transient response and dynamic current sharing. In the following
sections the thesis contributions are summarized, and future work is discussed.
5.1 Thesis Contributions The most significant contributions of this dissertation are:
1) Multi-Use and Fault-Tolerant Digital Controller IC: A flexible four-phase digital
PWM controller IC that can be used with interleaved, multi-output, and parallel dc-dc
switching converters operating at frequencies up to 10 MHz is proposed. The IC can be
programmed to operate with any number of converter phases and it is fault-tolerant.
During interleaved mode, if a failure in one of the phases occurs, it automatically
switches to operation with reduced number of phases by disabling the faulted phase and
adjusting the angles of the remaining ones. The key element of this IC is a new
multiphase digital pulse-width modulator (MDPWM) that utilizes a programmable
counter, programmable delay line, and digital logic with variable numbers representation.
The MDPWM produces four pulse-width modulated control signals whose switching
frequency can be adjusted between 100 kHz and 10 MHz with an effective resolution of
11 bits of input duty ratio commands. The controller IC is realized in standard 0.18 μm
CMOS process and exhibits low power consumption of 90.25 μA/MHz per phase. Due to
its flexibility and low-power consumption, the IC can be utilized in various applications
including low-power, battery-powered electronic devices where multiple supply voltages
are required.
CHAPTER 5. CONCLUSIONS AND FUTURE WORK 88
2) System for Dynamic Efficiency Optimization of Multi-phase DC-DC Converters: A
novel current-program mode digital controller and a multiphase dc-dc converter with
non-uniform current sharing that dynamically optimize converter efficiency over the full
range of operation are introduced. The converter phases are operated as binary-weighted
constant current sources, i.e. scaled in a binary-logarithmic fashion. To minimize the
system size and provide fast dynamic response, the phases switch at different frequencies
and their components are selected so that the most efficient operating points correspond
to the set currents. The digital controller operates on a modification of the “phase
shadowing” principle. Depending on the output load, the number of active phases is
dynamically configured. The new architecture of the controller does not require an
analog-to-digital converter for current measurement and is suitable for high-frequency
low power converters. An experimental 4-phase, 70-W, 12 V-to-1.8 V buck converter
utilizing the digital control architecture with logarithmic current sharing is built. A
comparison of the efficiency with an equivalent uniform current shared converter shows
that, at medium and light loads, the presented system results in efficiency improvements
of up to 6% and 25%, respectively.
3) Reconfigurable Digital Controllers with Multi-Parameter Estimation: A
reconfigurable digital controller architectures providing estimation of inductor currents,
identification of key converter parameters, and temperature monitoring of power switches
in single-phase and multi-phase dc-dc converters are presented. To perform component
parameter estimation and current estimator calibration with multi-phase converters, a
method based on “freezing” phase currents is proposed. The non-linear sensorless multi-
phase average current-mode controller utilizes the identified power stage parameters and
estimated inductor currents to provide fast transient response, while maintaining dynamic
current sharing and equalized thermal stress between converter phases. The equal thermal
stress of converter phases is obtained by regulating phase currents in order that the phase
conduction losses are balanced. The new controller eliminates the need for accurate
output voltage valley point detection and can operate at modest oversampling rates of the
output voltage. Both controller architectures are well-suited for on-chip implementation.
They provide a solution for combining a digital controller, current estimator and remote
temperature monitor on a single integrated circuit. The estimation of the average inductor
CHAPTER 5. CONCLUSIONS AND FUTURE WORK 89
current value over one switching cycle is based on the analog-to-digital conversion of the
inductor voltage and consequent adaptive signal filtering. The adaptive digital IIR filter is
used to compensate for variations of the inductance and dc resistance emulating converter
losses and affecting accuracy of the estimation. The operation of both controllers is
verified with a single-phase 5.5 V-to-1.5 V, 15-W buck converter and dual-phase 12 V-
to-1.8 V, 80-W, buck converter, both operating at a switching frequency of 500 kHz. The
results show that the current and temperature estimations are accurate with error less than
10%. The current estimation has the response time of one switching cycle. Dynamic
current sharing combined with small transient response time, under 5 µs for a 45-A load
current step, are obtained with the dual-phase buck converter having an output capacitor
of 500 µF. The digital blocks of the new multi-phase controller occupy only 0.43 mm2 of
silicon area when implemented in 0.18μm CMOS process.
5.2 Future Work
Future work could include a development of a digital controller IC that now intelligently
combines the best features of all presented controllers in this thesis. For instance, a system for
dynamic efficiency optimizations of multi-phase converters could be merged with the sensorless
non-linear average current-mode controller. The operation of the current-mode controller could
be also modified to dynamically balance converter losses from the information about phase
components and phase currents in the presence of high-frequency load steps. Finally, the current
sink for current estimator calibration and oversampling output voltage ADC for load transient
detection and estimation could be potentially eliminated or simplified (in case of the ADC) by
establishing a “digital communication link” between the switch-mode power supply and its load.
From the information passed to the controller about the operating mode, the specific activity of
the load device, and its current consumption, the current estimator could be periodically
calibrated while the requirement for oversampling of the output voltage would be eliminated.
90
Appendix A Filter Time Constant Calculation
To derive the equation that links the filter time constant τf and inductor time constant τL with
properties of the estimated current in order to perform the filter time constant tuning, the
following approximation is made. It is assumed that during the initial transient, the average
inductor current behaves as a ramp signal with a slope k. The Laplace transform of iL(t) in that
case is equal:
( ) .12s
ksI L ⋅= (A.1)
The sensed current according from the output of the RC filter according to (4.1) and (A.1) is then
equal to:
( ) ( ) ,1111
11
22f
L
L
f
f
L
f
LLsense s
ss
kss
sk
sssIsI
ωω
ωω
ττ
ττ
++
⋅⋅⋅=++
⋅⋅=++
⋅= (A.2)
where ωf=1/τf and ωL=1/τL. The sensed current Isense(s) now can decomposed as:
( ) ,2f
sense sC
sB
sAsI
ω+++= (A.3)
where coefficients A, B, and C are:
,Lf
LfkAωωωω⋅
−⋅= (A.4)
,kB = (A.5)
.Lf
LfkCωωωω⋅
−⋅−= (A.6)
APPENDIX A. FILTER TIME CONSTANT CALCULATION 91
91
By using the fact that the middle term of Isense(s) in (A.3) is equal to IL(s) from (A.1) and after
applying the inverse Laplace transform, the sensed inductor current becomes equal to:
( ) ).()1( tiekti Lt
Lf
Lfsense
f +−⋅⋅
−⋅= ⋅−ω
ωωωω
(A.7)
The difference ΔIpeak between the estimated current and actual inductor current when the output
voltage peak point occurs at t= ΔTpeak is then equal:
(A.8)
where the slope k is equal to ΔI/ ΔTpeak.
From an approximation that e-x ≈ 1-x+x2/2, where x= ωf∙ΔTpeak, to simplify (A.8), it can be shown
the ratio between ωf and ωL is:
(A.9)
Finally, by rearranging (A.9) the inductor time constant τL now can be expressed in terms of the
filter time constant τf as:
(A.10)
92
Appendix B Quantization Error Effects on Current Estimator Accuracy
The accuracy of the digital current estimator is affected by quantization errors introduced by
the input and output voltage ADCs. The steady-state estimated inductor current, according to
Ohm’s law is equal:
eq
outinsense R
nvnvdni ][][][ −⋅= . (B.1)
The worst-case absolute error of isense[n] is found from the sum of absolute values of the partial
derivatives of (1) multiplied with the absolute errors of vin and vout :
outout
sensein
in
sensesense v
viv
vii ∆⋅+∆⋅=∆
δδ
δδ
. (B.2)
After substituting the partial derivatives of isense[n], the absolute error of isense[n] then becomes
equal to
outeq
ineq
sense vR
vRdi ∆⋅−+∆⋅=∆
1, (B.3)
where Δvin, Δvout, are absolute errors of the input voltage and output voltage. Both errors Δvin and
Δvout in the worst case are equal to the half of the quantization step for the input and output ADC.
Table B.2: Current estimator relative error versus quantization step of the output voltage ADC.
relative error [%]
Vq[mV]
1.0 1.1 2.0 2.1 4.0 4.3 8.0 8.5
16.0 17.1
For example, we may consider a 12 V-to-1.5 V buck converter operating at a full load of 30 A
and having Req of 15 mΩ, an output voltage quantization step of ΔVq = 4mV and the input one 4
times larger. The relative error of the current estimation then becomes equal to 4.1%. Table B.1
APPENDIX B. QUANTIZATION ERROR EFFECTS ON CURRENT ESTIMATOR ACCURACY 93
93
provides the values of the relative errors for the current estimation calculated for different sizes
of output quantization steps ΔVq.