Capacitacion Troubleshooting Pasolink

Post on 21-Oct-2015

221 views 15 download

Tags:

Transcript of Capacitacion Troubleshooting Pasolink

CAPACITACION

TROUBLESHOOTING

COMPATIBILIDAD FAMILIA PASOLINK

IDU ODU

V4

4PSK

Mx(850M)

4PSK,16Q

NEO

4-128Q/28M

XPIC/BB LRZ

IDU & ODU Compatibility

Module Replacement

IF Freq.

Mx(340M)

4PSK,16Q

NEO compact

4-16Q/28M1+0

1+1/1+0 exp.

(1)(3)

(2)(3)(4)

(1) Up to 40MB/16QAM

(2) Up to 80MB/16QAM

(3) without XPIC

(4) without BB LRZ

NEO compact

5E1-16E1

4-16Q

V3

V4

Mx

850MHz/

70MHz

Protocol

EHG

BB LRZPASO+

SDH/128Q

BB LRZ

PASO+

SDH/32Q

F/W version up

*)future release

NEO standard

5E1-STM-1

4-128Q

XPIC

INSTALACION RECOMENDADA

Recomendaciones de puestas a tierra

Puesta a tierra en la TRP

Puesta a tierra en la MDP

TROUBLE SHOOTING

DESCRIPCION GENERAL RADIOS

PASOLINK

PASOLINK V4

PASOLINK V4

CARACTERISTICAS

Ancho de banda total 34 MB.

Interfase para trafico ETHERNET.

Posibilidades de configuración 1+0 Y

1+1 (HS, SD, TP).

Modulación QPSK.

Bandas de operación

7,8,13,15,18,23,26 Y 38 Ghz.

Gestión por NMS.

Conexión de alarmas externas.

E1 a 75 O 120 OHM.

Potencia de TX ATPC O MTPC.

Fácil configuración.

PASOLINK V4

DEM invertida: Según la tabla anexa, el DEM debe ser configurado deacuerdo al tipo de ODU:

ALARMAS V4

PASOLINK MX

PASOLINK MX

CARACTERISTICAS

Ofrece capacidades de

transmisión de 5 hasta

40x2Mbps ó de 5 hasta

32x2Mbps más dos

señales 10/100 Base-

Tx. Al igual que el

equipo Pasolink V4, la

flexibilidad en su

configuración va desde

1+0 hasta 1+1 con las

opciones HS, TP y SD.

Normal Indication Values

7/8 GHz +27 to –3 dBm ±2.5 dB +21 to –3 dBm ±2.5 dB

13 GHz +25 to –5 dBm ±2.5 dB +19 to –5 dBm ±2.5 dB

15/18/23 GHz +23 to –7 dBm ±2.5 dB +17 to –7 dBm ±2.5 dB

26 GHz +20 to –10 dBm ±2.5 dB +14 to –10 dBm ±2.5 dB

38 GHz +15 to –15 dBm ±2.5 dB +9 to –15 dBm ±2.5 dB

RX Level *2

ODU PS MON *3 7-38 GHz

BER

RF BAND

TX Power *1

Item

–30 dBm

–43 V (–32 to –46 V DC)

less than 3.0E-4 to 3.0E-6

QPSK 16 QAM

PASOLINK MX

Valores típicos de enlace

*1:Depende del los valores de control de Tx.

*2:Varia dependiendo de el plan de desempeño y condiciones de

propagación.

*3:Depende de la longitud de el cable entre la IDU y la ODU

QPSK 16QAM

3.5 MHz - 10 Mbps

7 MHz 10 Mbps 20 Mbps

14 MHz 20 Mbps 40 Mbps

28 MHz 40 Mbps 80 Mbps

Frequency

Separation

Transmission Capacity

PASOLINK MX

Anchos de banda modulación y separación de canal.

PASOLINK MX

Curva de RSL para Pasolink MX

Configuración por PNMT

PASOLINK MX

PASOLINK MX

Link Performance Monitor

EB (Error Block). Se trata del número de bloques errados por

unidad de tiempo (1 seg). Se debe tener en cuenta que un código

del tipo BIP-8 constituye 1 único bloque y no 8 aislados. De este se

deriva la Tasa de Bloques Errados EBR (EB Rate).

ES (Error Second). Es un segundo donde al menos un bloques

tiene uno o más errores. Lo cual da lugar a la Tasa de segundos

con error ESR (ES Rate);

SES (Severaly Error Second). Es un segundo con más de 30% de

bloques con error o al menos un período SDP.

SDP (Severely Disturbed Period) es un período de 4 bloques

consecutivos con una BER>10-2. La persistencia de SDP durante

varios segundos puede producir la desconexión de canales

conmutados. Se desprende entonces la Tasa de segundos con

muchos errores SESR (SES Rate).

BBE (Background Block Error). Estos bloques con error no forman

parte de SES (inferior al 30%). Se obtiene la tasa de error de

bloque de fondo BBER (BBE Rate) (excluyendo los bloques con

SES y US).

US (Unavailability Second). Se cuenta desde 10 SES consecutivos

hasta 10 segundos seguidos sin SES. La indisponibilidad se

considera cuando ocurre el efecto en uno o ambos sentidos. Los

ESR, SESR o BBER solo se evalúan en estado de disponibilidad.

PASOLINK MX

Descarga de archivos de NMS y Equipment.

Login : Admin

Password : ********

12345678

PASOLINK MX

Conexión por LCT.

--- NEC PDH RADIO Ver.

1.0.27 ---

0. Logout

1. Alarm / Status

2. Performance Monitor

3. Provisioning Data

4. System Configuration

5. Inventory Data

6. Relay / House Keeping

7. Maintenance

Enter Selection :

PASOLINK MX

Configuración por LCT

--- RSL Monitor ---

08/15 15:05:01,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:02,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:03,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:04,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:05,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:06,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:07,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:08,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:09,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:10,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:11,-55,+14,-54,+14,1,1,1,0,0,0

08/15 15:05:12,-55,+14,-54,+14,1,1,1,0,0,0

PASOLINK MX

Monitoreo de RSL por LCT

Verificación de inventario por LCT

PASOLINK MX

MODULACIÓN DE

INICIACIÓNCONDICIÓN DE ALARMA

ALARMA INICIADA

INDICACIÓN DE LED EN IDU

RF CKT

Señal de entrada de FI desde IDU perdida.

IF INPUT ALM ODU

Potencia de RF de transmisión disminuye 3 a 6 dB desde nominal

TX PWR ALM ODU

ODU de 7/8/13/18/23/26/38 GHZ:

Bucle de APC del oscilador local de TX o Primer oscilador local para RX se desbloquea.

APC 1 ALMODU

ODU de 7/8/13/18/23/26/38 GHZ:

Bucle de APC del segundo oscilador local RX se desbloquea

APC 2 ALM ODU

El nivel de entrada de recepción disminuye del nivel preajustado desde el

nivel de silenciamiento.RX LEV ALM ODU

Falla la comunicación entre la IDU y ODU OPERATION ALM ODU

PASOLINK MX

PASOLINK MX

PASOLINK PLUS

PASOLINK PLUS

Descripción

El equipo Pasolink+

el cual ofrece 1 STM-

1 ó 2xSTM-1

utilizando la

transmisión co-canal

con doble

polarización y

equipado con XPIC

(Candelador de

Interferencia por

Polaridad Cruzada).

Rendimientos generales del sistema

PASOLINK PLUS

PASOLINK PLUS

Rendimientos generales del sistema

PASOLINK PLUS

IF Pasolink Plus

TIPOS DE TRPs PASOLINK PLUS

PASOLINK PLUS

Instalación de un radio Pasolink Plus Xpic (2STM1)

PASOLINK PLUS

Configuración Xpic con TP

PASOLINK PLUS

Curva de RSL típica para Pasolink Plus.

PASOLINK PLUS

Configuración y monitoreo por PNMT

--- SDH RADIO Ver. 1.4.6 ---

0. Logout

1. Alarm / Status

2. Performance Monitor

3. Provisioning Data

4. System Configuration

5. Inventory Data

6. Relay / House Keeping

7. Maintenance

PASOLINK PLUS

Configuración y monitoreo por LCT.

PASOLINK PLUS

Alarmas IF y MODEM Pasolink Plus

Alarmas MODEM y TRP

PASOLINK PLUS

PASOLINK NEOc

PASOLINK NEOc

Descripción general

Interfaces.

Modulación.

Temperatura de operación.

MDP Híbridos

TRPs

Hardware.

PASOLINK NEOc

Diagrama de flujo básico de la MDP.

PASOLINK NEOc

BW trafico TDM vs. LAN

PASOLINK NEOc

ALARM ODU ALARMS DETECTED

ODU CPU ALM /CBL Open ODU CPU Failure or IF cable open ODU

ODU ALM ODU Total alarm ODU

TX POWER ALM ODU Output power decreased ODU

TX INPUT ALM ODU TX IF Input level decreased ODU

APC ALM ODU Local Oscillator un-lock alarm ODU

RX LEVEL ALM ODU RX Level decreased ODU

LO REF ALM ODU LO reference signal loss ODU

Alarmas en la TRP

PASOLINK NEOc

Alarmas IF y MODEM.

PASOLINK NEOc

Alarm INTERFACE - PDH ALARMS

INTFC UNEQUIPPED Main interface is unequipped CTRL

TYPE MISMATCHMounted interface is different

from the configured CTRL

INTFC MODULE Main interface module failure INTFC

INPUT LOSS CH#Loss of E1 input or E3 input or WS

CH input INTFC

USAGE ERROR CH#E1 signal detected at the input of

“not used” Channel INTFC

AIS GENERATED CH# AIS generated and sent to MUX INTFC

AIS RECEIVED CH# AIS received form MUX INTFC

LAN LINK PORT1/2 LAN port Link status INTFC

LAN COLLISION PORT1/2 LAN collision occurred INTFC

LAN RDI ALM PORT 1/2 LAN RDI alarm received INTFC

Alarmas en la interfase PDH

PASOLINK NEOc

PASOLINK NEO std.

PASOLINK NEO std.

Características generales.

1 2 3 4 5 6 7 8 9 10 11 12 13

14

1. IF In/Out 5. DC 9. AUX/ALM 13. STATUS

2. XIF In/Out 6. Power Switch 10. SC IN/OUT 14. INT CARD

3. XPIC CTRL 7. LCT 11. EOW/CALL/PROTECT

4. Status LEDs 8. NMS 12. MMC

Descripción de la MDP

PASOLINK NEO std.

Descripción tarjeta CTRL y MODEM.

PASOLINK NEO std.

Diagrama de flujo de la MDP

PASOLINK NEO std.

340 MHz

140 MHz

IF Pasolink NEO std.

PASOLINK NEO std.

Baseband INT

PASOLINK NEO std.

Baseband INT

PASOLINK NEO std.

Baseband INT

PASOLINK NEO std.

Baseband INT

PASOLINK NEO std.

Upgrade NEO std.

PASOLINK NEO std.

Configuración Xpic 2xSTM1

PASOLINK NEO std.

Barra de titulo Barra de NEespecifico

Diagrama debloques

DataWindow

Login User

BarradeMenúcomún

Barradeherramientascomún

Administración y monitoreo por PNMT

PASOLINK NEO std.

Menú de aprovisionamiento del radio enlace

.

Frec. de TX y RX.

Potencia de TX.

Modulación e Interfase instalada.

Frame ID.

PASOLINK NEO std.

PASOLINK NEO std.

Menú Inventory.

PASOLINK NEO std.

Niveles RSL.

PASOLINK NEO std.

Menú Mantenance.

PASOLINK NEO std.

Menú Mantenance.

PASOLINK NEO std.

Menú de configuración.

PASOLINK NEO std.

Características de la configuración.

PASOLINK NEO std.

Umbral de Alarma de BER PDH.

Umbral de Alarma de BER SDH.

Umbrales de BER

PASOLINK NEO std.

Configuración de un puerto LAN.

PASOLINK NEO std.

Performance Monitor.

PASOLINK NEO std.

Lectura del EventLog.

PASOLINK NEO std.

Alarmas.

PASOLINK NEO std.

Indicadores interfase 48E1

PASOLINK NEO std.

Indicadores interfase 16E1+LAN.

PASOLINK NEO std.

Indicadores interfase STM1.

PASOLINK NEO std.

Alarmas generadas por la TRP.

PASOLINK NEO std.

Alarmas generadas por el MODEM.

PASOLINK NEO std.

Alarmas Interfase STM1.

PASOLINK NEO std.

Alarmas de la tarjeta CTRL.

PASOLINK NEO std.

• En los radios Nec Pasolink existen diversas versiones de Firmware que habilitan funcionalidades del radio de acuerdo con las necesidades del cliente por ejemplo versiones de Firmware para una determinada interfaz o para conectarse al gestor, un Software Key para habilitar la función XPIC en un equipo etc. De ahí la necesidad de interpretar el menú INVENTORY, para establecer si el equipo tiene habilitada o no la funcionalidad que se requiere, o si la versión de Firmware soporta la tarjeta conectada.

Versiones de Firmware y Software Key.

PASOLINK NEO std.

Visualización de versión de Firmware.

PASOLINK NEO std.

El Software Key define el

aprovisionamiento del radio y sus

aplicaciones habilitadas.

PASOLINK NEO std.

• Los puntos de posible falla se definen de acuerdo a la falla reportada

así:

• Fallas en Modulación-Demodulación.

• Fallas de Tributario, STM1 o Ethernet.

• Fallas en IF.

• Fallas en RF.

• De acuerdo a la falla reportada verificaremos la parte del enlace que

reporta el evento.

Resumen.

PASOLINK NEO std.

• Falla en Tributario, STM1 o Ethernet

• Tributario: Cuando se presentas AIS en los tributarios (AIS CH N) es necesario verificar la ruta física que los cables coaxiales conectados a la I/O Board, el equipo que genera la señal E1, generalmente es una alarma externa al radio por lo que se debe buscar externamente.

• STM1: En los STM1 las fallas mas frecuentes son LOF, LOS y E-BER es importante verificar si la alarma generada proviene del MUX (equipo de donde se origina el STM1) o de DMR (indica perdida en la sección de radio).

• Ethernet: Las alarmas LAN LINK (puerto Lan sin cable conectado), LAN COLLISION (generación de Broadcast excesivo) Y LINK LOSS FORWARDING (caída de conexión en uno de sus extremos) su origen y solución se pueden detectar fácilmente puesto que estas alarmas son locales.

Puntos de falla.

PASOLINK NEO std.

Puntos de falla.

• Fallas en IF

• Las fallas en IF se definen como problemas en la comunicación del

MODEM con la ODU y se pueden generar por los siguientes factores:

• Falla en el MODEM: Por corrosión, presencia de sulfato o daño por

descarga podremos ver en el Log del equipo alarmas relacionadas como

MODEM MODULE. Cuando el EventLog nos muestra la alarma IDU-ODU

LINK es necesario verificar la salida de voltaje DC del MODEM, pues si este

voltaje es cero debemos reemplazar el modulo.

PASOLINK NEO std.

Puntos de falla.

• Fallas en cable IF: Para identificar fallas en el cable IF debemos aclarar que la alarma que define esta falla es IDU-ODU LINK, cuando esta alarma se presenta y hemos descartado el MODEM como fuente de la misma ubicaremos su origen verificando lo siguiente:

• Conectores tipo N o TNC según el caso

• Verificar que los conectores de los extremos del cable IF no presenten cortos ya sea por humedad o por mal ensamblaje de los mismos, o que se encuentren los conectores aislados del cable.

• Cable RG8

• Verificar el correcto encintado de los conectores para que no se conviertan en punto de falla al ingresar agua al conector o al cable IF, de igual manera verificar los puntos donde el cable IF se aterriza en la torre pues debido a que se encuentra vertical es donde el encintado falla frecuentemente permitiendo el paso de agua.

PASOLINK NEO std.

Puntos de falla.

• Fallas en RF

• Se define como fallas en RF las fallas que se presentan entre la TRP del sitio

A y la TRP del sitio B incluyendo los Jumpers, Híbridos y feeder en los dos

extremos. Es importante definir por quien realiza el mantenimiento cual es la

etapa afectada pues en RF una alarma se puede presentar por varios

orígenes, por ejemplo:

• HIGH BER-LOW BER: Esta alarma indica un nivel bajo de RX que se puede

presentar por Jumpers en mal estado, Hibrido o Feeder con Humedad, TRP

atenuada, radio enlace desalineado, interferencia o desvanecimiento por

causas atmosféricas. Las alarmas RX LEVEL y THRESHOLD se pueden

originar por las mismas causas.

PASOLINK NEO std.

• La interferencia es la recepción de una señal de radio indeseada que impide el

normal funcionamiento de un canal de comunicaciones.

• La prueba mas utilizada para la detección de una interferencia en radio

Pasolink se realiza apagando uno de los extremos del punto a punto, y

conectados al radio que no se apaga en el modo LCT, monitoreamos el nivel

segundo a segundo, buscando encontrar una señal no deseada en RX, luego

se invierte apagando el extremo contrario.

Fallas por Interferencia.

PASOLINK NEO std.