Post on 09-Mar-2018
What does it mean for contractors
Structural connections with post-installed rebar
Ensure that the execution of the jobsite is according to the specifications.
Ensure that the installer is capable of correctly installing the anchor.
Should ensure that the change management procedure outlined in clause 10 is followed when an alternative anchor is proposed to that specified.
If aware of any changes to the assumptions made by the specifier in designing / selecting the specified anchor, should Inform the specifier and await instructions.
•
•
•
•
Especially suitable for large-diameter and/or deep embedment depthsETA for rebar: Approved rebar size is stated within ETA on page 3
•
•
Hilti. Outperform. Outlast. Customer Service: 6777-7887
Hilti Far East Pte Ltd | 20 Harbour Drive, #06-06 PSA Vista, Singapore 117612 | T 6777 7887 | F 6777 3057 | www.hilti.com.sg
Hilt
i = r
egis
tere
d t
rad
emar
k o
f H
ilti C
orp
., S
chaa
n | P
rint
ed in
Sin
gap
ore
| M
ay 2
015
| © 2
015
| Rig
ht o
f te
chni
cal a
nd p
rog
ram
me
chan
ges
res
erve
d S
. E. &
O.
BS8539 is the code of practice for selection and installation of post-installed anchoring. It is also linked to the relevant European regulations, especially with respect to selecting products with the CORRECT European Technical Approval or Assessment’s (ETA) for the application. Who does it affect? Everyone; designers, specifiers, contractors, installers, testers, manufacturers and suppliers.
HIT-RE500 (SD) Epoxy Adhesive Anchor designed to meet the most stringent standards of the latest building codes.
Anchoring structural steel connections
Fulfills the requirements of the most demanding ETA C2 approvals for seismic applicationsETA for anchor (cracked / uncracked concrete): Approved anchor size is stated on cover page
•
•
HIT-HY200-R achieves the highest bond strength of all adhesive mortar.
BS8539 Your Roles and Responsibilities for Post-Installation
Hilti offers best in class solutions with international ETA approvals
HILTI can offer support from design to installation.•
••
•
FREE calculation software and design with PROFISInstallation training for contractors on-site to ensure safe useOn-site supportHilti provides 2.5% complimentary on-site pull-out test
(e.g. extension/connection to walls, slabs, stairs, columns, foundations, etc.)
(e.g. steel columns, beams, etc.)
Hilti. Outperform. Outlast.
Eurocode, EC2 Use?
BEST IN CLASS SOLUTIONS WITH
INTERNATIONAL ETA APPROVALS.
Z30836.14 8.06.01-106/14
European Technical Assessment
ETA-12/0083 of 13 May 2014
General Part Technical Assessment Body issuing the European Technical Assessment:
Deutsches Institut für Bautechnik
Trade name of the construction product Injection System Hilti HIT-HY 200-R for rebar connection
Product family to which the construction product belongs
Post-installed rebar connection with Hilti injection mortar HIT-HY 200-R
tfahcsllesegneitkA itliH rerutcafunaM9494 SCHAAN FÜRSTENTUM LIECHTENSTEIN
ekreW itliH tnalp gnirutcafunaM
This European Technical Assessment contains
22 pages including 18 annexes which form an integral part of this assessment
This European Technical Assessment is issued in accordance with Regulation (EU) No 305/2011, on the basis of
Guideline for European technical approval of "Metal anchors for use in concrete", ETAG 001 Part 5: "Bonded anchors", April 2013, used as European Assessment Document (EAD) according to Article 66 Paragraph 3 of Regulation (EU) No 305/2011.
Structural Rebar connections - EC2 / EOTA TR023
Work dustless with the ETA approved SAFEset system for a healthy and reliable working environment
Work dustless with the ETA approved SAFEset system for a healthy and reliable working environment
Applications
Technical data
Productivity plus Productivity plus
Structural rebar connections and extensions can be safely designed like cast-in connections utilizing the design provisions provided within Eurocode 2 and EOTA TR023
*Test in cracked concrete is not required according to TR023.
Approvals
Rebar Diameter Range
ETA for rebar connections
4 hours fire resistance
T8 – T40
ETA 08/0105, ETA11/0492
Structural connections with post-installed rebarsStructural renovation / upgrades with post-installed rebarsSubstitution of misplaced / missing rebarsReinforced concrete waler with post-installed rebars
••••
Eurocode, EC2 use?
On 1st April 2015, Eurocode design standard has replaced British Standards as Singapore’s prescribed building codes for structural design (http://www.bca.gov.sg/Newsroom/pr25032013_EC.html). This also means that there is now a specific set of codes that also addresses the design method post-installed rebar and anchors.
In EC2 Clause <EN1992-1-1:2004 (E)>, it states that the design methods for post-installed rebar connections must follow EC2/Technical Report 023. And for post-installed anchors, the design must follow ETAG 001 Annex C. Thus, the design methods for the two applications are completely different.
Anchor connections - ETAG 001 Annex C / TR 029
Applications
The European Technical Approval Guideline 001 “Metal Anchors for used in Concrete” sets out the basis for assessing anchors to be used in concrete.
Wide range of fastening applications in concreteAnchoring structural steel connections (e.g. steel columns, beams)Anchoring secondary steel structures (e.g. staircases, steel ledgers)Anchoring railings / safety barriersFastening façade bracketsFastening brackets and channels
••
••••
Technical data
Approvals
Mechanical anchor diameter range
Threaded rod diameter range
Rebar diameter range
ETA for cracked or uncracked concrete
2 hours fire resistance
M6 – M24
M8 – M39
M8 – M32
Traditional Method
With Hilti Hollow Drill Bit and VC 20/40 Vacuum
Up to 60% faster!
Hilti PROFIS Rebar for design calculation for rebar connections
Cordless electric dispensers for quick, efforless injection
Injectable mortars for versatile, secure fastenings in concrete
Powerful combihammers for tough drilling jobs
Hilti PROFIS Rebar
Hilti PROFIS Anchor for design calculation for anchor connections
Service and advice to ensure the job is done right
Injectable mortars for versatile, secure fastenings in concrete
Powerful cordless combihammers for tough drilling jobs
Traditional Method
HIT-HY 200 System with HIT-Z rods
Up to 60% faster!
Hilti PROFIS anchor
,