ARCH 2020 ‐TDS Project 3 – Steel Project – REVIT Drawings (Extracts only) DT 175‐02 ARCHITECTURAL TECHNOLOGY
Emma Harrington 11/7/18 Student Number: C17750321
TDS PROJECT 3: Steel Community Building (Main Building & Building B) DT 175 ARCHITECTURAL TECHNOLOGY
Date: 07 November 2018 Page 1 Student Name: Emma Harrington Student Number: C17750321
List of Revit Drawings
1. Site Plan / Location Plan (1: 200) / (1: 5000)
2. Plans & Elevations 1st Floor Plan (1:100) 1st Floor Reflected Ceiling Plan (1:200) 2nd Floor Roof & Roof Finishes (1:200) 2nd Floor Roof Finishes (1:200) 7th Floor Plan with Astrodome ‐ Building B) (1:100)
3. Elevations (North & South) (1:100)
4. Building Section – South Elevation (1:50)
(1:10) (1:10) (1:5) (1:10) (1:10)
(1:20) (1:10) (1:10)
(NTS)
5. Façade Detail & Sections Slim Deck Floor & Column Detail Column & Foundation Detail Cladding Rails & Column Connection Detail Roof Trusses & Column Detail Deck Door Threshold Detail
6. Plan & Details – Toilet & Coffee Dock Toilets ‐ Floor Layout Cross Section – Unisex WC Coffee Dock – Floor Layout
7. Sketches
(NTS)
UP
9
8
7
6
5
4
3
2
1 18
17
16
15
14
13
12
11
10
S1 S2 S3 S4 S5 S6 S7
A
B
C
D
E
F
50 m²
Meeting Room1
9960
5100
50 m²
Meeting Room2
50 m²
Meeting Room3
50 m²
Meeting Room4
TDG M - 1.4.6.1 450mm (min) diameter manoeuvring space provided between the swing of the door, the WC pan and the side wall of the compartment
Sanitary Facilities: Building facilitats 375 people assume 50 / 50 spilt -c. 190 Ladies Toilets: - 2 WC for 50 - 250 females, plus 1 for every additional (or part of 100)- 1 WHB per toilet- 1 handdryer per 2 x WHBNote: As a public assembly building enlarged toilet cubicle added with required dimensions outlined plus 750mm (min activity space clear of door swing).Male Toilets: - 1 WC per 100 - 400 males- 1 Urinal per 50 males- 1 WHB per WC & 1 per 5 UrinalsWheelchair Acceessible Unisex:- 1,800 x 2,500mm to enable 1800 x 1800mm wheelchair turning circle- See highlighted dimensions in drawing 0
2080
3080
Acitivity Space 300mm in front of cubicles & 300mm in front of WHB
750
450
876
750
700 700400
500
600
500
1280
470
180
1800
1800
Reception
1355
1407
Dis
h W
ashe
r O
ven
1500
1
9911
External Deck with Outdoor
Seating11m x 15m
Artificial glass on Metal Deck
Raised Floor:Pedestal Layout for Kingspan Alpha V Pedestals with Kingspan RMG600 Raised Access Floor (600 x 600mm). Class 0 to BS476 fire rating. This floor is suitable for General Office use with heavy equipment, Educational Accomodation and Public Access. To be fitted according to manufacturers instructions
Coffee Dock Seating Area: Note: 1,355mm between tables to allow 2 people to pass comfortably. 50mm minimum space between chair & wall to allow seating access. (Reference: Metric Handbook 6th Edition (P34-35). See Coffee Dock plan & details for TGD M 1.5.5 Refreshment Facilities minimum requirements.
Kitchen Area
Ref
riger
ated
D
ispl
ay
1600
Cas
h R
egis
ter
& D
rinks
C
olle
ctio
n
1,800 x 1,800mm
Wheelchair Turning Circle
8 m²Male WC
9 m²Female WC
6 m²
WheelchairAccessibleUnisex WC
12 m²
Lift Lobby 1stFloor
18 m²
Main Stairs(Fire
Protected)
1620
1800
18 m²
Stairs No 2(Fire Stairs)with Refuge
Area
5000 5000 7500 7500 7500 7500
5000
2000
7000
7000
4000
2500
0
14980
12719
910
1375
1358
1376
114
1344
1344
1365
1357
814
TGD B: Travel Distance 35m
TGD B: Fire Travel Distance 14m
TGD B - Travel Distance 15.5m
TGD B Fire: Means of EscapeNote: Group 5 Public Assembly Buidlings- All travel distances are less than 32m (Seating in Rows) and 45m (Other Areas) in more than one direction- Two escape routes as building will facilitate between 1- 500 people- Building has been fitted with Automatic Fire Detection & Alarm System with Dry Sprinkler system- All Staircases are 1,200mm wide with Refuge Areas for less ambulant visitorsFire Safety- There are 2 x Class A extinguishers on 1st Floor both Located beside Exits plus additional in Kitchen
1,800 x 1,800mm
Wheelchair Turning Circle
1,800 x 1,800mm
Wheelchair Turning Circle
1,800 x 1,800mm
Wheelchair Turning Circle
1,800 x 1,800mm
Wheelchair Turning Circle
Curtain WallKanweer AA110 65mm (See South Elevation for further details)
1
004
-
---
5
005
S1 S2 S3 S4 S5 S6 S7
BC
D
E
F
Suspended Ceilings:(600 x 600mm) Tile have been placed above Meeting Rooms and Bathrooms (3,150mm)They are also placed above Stairs but they are not visible in this level as they go up to the Roof (6,300mm)
S1 S2 S3 S4 S5 S6 S7
A
BC
D
E
F
5000 5000 7500 7500 7500 7500
5000
2000
7000
7000
4000
2500
0
40000
1100
0
Open Deck - No Roof
Roof:- Kingspan Topdek Insulated Panels (Anthracite Grey)PIR Insulation 120mm,U Value 0.15W/m2K,
Panels 1000mm x 12m on Kingspan Multibeam Purlins @ 3m centres.Note: Fit to Manufacturers Instructions- Fall of Roof 1:80 (Slope 0.720)
S1 S2 S3 S4 S5 S6 S7
A
BC
D
E
F
Roof:- Kingspan Topdek Insulated Panels (Anthracite Grey)PIR Insulation 120mm,U Value 0.15W/m2K,
Panels 1000mm x 12m on Kingspan Multibeam Purlins @ 3m centres.Note: Fit to Manufacturers Instructions- Fall of Roof 1:80 (Slope 0.720)
Scale
Checked by
Drawn byDateProject numberOrganisation Name
Project NameSheet Name
Client NameEmma Harrington
DT175-02 2018_19
Asindicated
1st Floor, ReflectedCeiling & Roof Plan
01
DT175 02 TDSProject 2
Noel Brady 11/06/18
Checker002ALinenhall
Dublin Institute ofTechnology Emma Harrington
1 : 1001 First FFL
1 : 2002 First Floor Ref Ceiling Plan
1 : 2002 Second (Roof)
1 : 2002B Top of Parapet (Roof Finish)
1 First FFL3150
-1 Top Found-600
S1 S2 S3 S4 S5 S6 S7 S8 S9 S10
2 Second (Roof)9450
3 Third FFL15750
4 Fourth FFL22050
5 Fifth FFL28350
6 Sixth Floor FFL34650
7 Seveth Floor FFL(Observatory Roof)
37150
1A First6300
2A Second12600
3A Third18900
4A Fourth25200
5A Fifth31500
Construction Notes:
Primary Structure:- Universal Columns - 305 x 305 x 97mm- Universal Beams - 406 x 178 x 60mm (Smallest Span 4m, Largest Span 7.5m):- Cross Bracing: L Equal L Angles - 150 x 150 x 12Span diagonally between each column (every 2nd one on West Elevation due to Car Park Entrance & Exit)
Secondary Structure:- Cladding Rails: PFC Parallel Flange Chanels 100 x 50 x 10mm @ 600mm centres- Kingspan Multibeam Purlins:100 x 50 x10mm @ 3,000mm centres- Kingspan Eaves Beam:
Territary Structure:- Kingspan KS1000RW Insulated Secret Fix Wall Cladding 8mm Anthracite Grey Aluminum Facade with 115mm PIR Insulation, Fire Rating Class 0.
Curtain Walls:Kanweer 110AA 65mm stick system with zoned drainage.
Foundations:Reinforced Concrete Pad Foundation (900 x 600 x 300) with Base Plate
Kingspan Cladding Rails to support
external cladding
3150
Kingspan KS1000RW Insulated Secret Fix Wall Panels
Kanweer AA 110 65mm Curtain Walling has been hidden in this view for illustrative purposes
2B Top of Parapet11000
5
005
0 Ground FFL0
1 First FFL3150
-1 Top Found-600
S8S9S10
2 Second (Roof)9450
3 Third FFL15750
4 Fourth FFL22050
5 Fifth FFL28350
6 Sixth Floor FFL34650
7 Seveth Floor FFL(Observatory Roof)
37150
1A First6300
2A Second12600
3A Third18900
4A Fourth25200
5A Fifth31500
2B Top of Parapet11000
Scale
Checked by
Drawn byDateProject numberOrganisation Name
Project NameSheet Name
Client NameEmma Harrington
DT175-02 2018_19
1 : 100
Elevations - North &South
01
DT175 02 TDSProject 2
Noel Brady 11/04/18
Checker003Linenhall
Dublin Institute ofTechnology Emma Harrington
South Elevation: Main Building and Building B North Elevation: Building B
1 First FFL3150
160
Kingspan RMG600 Raised Access Floor Panel (600x 600mm)
31
Kingspan Alpha V Pedestal System
Kingspan Multideck V146 Slimdeck Floor sitting within Universal beam - reinforced with concrete screed on top
Universal Beam 406 x 178
PIR foil backed insulation attached to underside of concrete floor to stop cold bridge. Insulation within Universal beam
Internal Wall: 1 hour Fire Rating 12.5mm Plasterboard x 2, on 70mm Metal Stud
Universal Column 305 x 305
Kingspan Multi Beam Cladding Rail 100 x 50 x10mm @ 600mm centres, attached to UC and with Bolt on Cleat (See Call Out).
Kingspan KS1000 RW Insulated Secret Fix wall panel 8mm Aluminum metal cladding with 115mm PIR Insulation
175 x175mm Moment End Plate connecting UB and UC
175
175
0 Ground FFL0
-1 Top Found-600
900600
Column to Foundation Connection: - 305 x 305mm Universal Column on 500 x 500mm Steel Base Plate with 4 Bolt connections 305
30
500
2 Second (Roof)9450
2B Top of Parapet11000
Kingspan KS1000 RW Insulated Cladding Panel connected to Cladding Rails (See Call Out Opposite for further detail on connection)
Kingspan Topdek Insulated Roof - 115mm PIR Insulation with 8mm Metal Cladding on surface
Mono pitch Pratt Roof Truss (Fall 1:80) spans of 25m and 14m
Kingspan Multibeam Purlin 315mm on top of Pratt Truss
115
Pratt Roof Truss connected to UC with clip angle
Kingspan Multibeam Cladding Rails 100 x 50 x 10 @ 600mm centres
L Equal Leg Angle Cross Bracing 150 x 150mm
1 First FFL3150
Kanweer AA100 65mm Curtain Wall System with Thermally Broken Windows
Door Head
Door 1500 x 3150mm Glass Door with 12mm thermally broken Glass
Kanweer Vertically Capped Mullion 50 x 150mm
Door Threshold
Outdoor Deck Artifical Grass embedded on Metal Deck (60mm)
Drain
PIR Insulation 120mm secured to underside of floor deck
Interior Exterior
120
406 x 178 mm Universal Beam
Kingspan Multideck V146 Slimdeck Floor
Scale
Checked by
Drawn byDateProject numberOrganisation Name
Project NameSheet Name
Client NameEmma Harrington
DT175-02 2018_19
Asindicated
Details - Callouts fromFacade Section
01
DT175 02 TDSProject 2
Noel Brady 11/04/18
Checker005Linenhall
Dublin Institute ofTechnology Emma Harrington
1 : 10CC - Callout of Slimdeck Flooring
1 : 5Callout of Cladding Connection
1 : 10South - Column & Foundation Detail
1 : 10West - Roof & Column Connection
1 : 10CC - Cross Section of Deck Threshold
TDG M - 1.4.6.1: Standard WC Cubicle- 450mm (min) diameter manoeuvring space provided between the swing of the door, the WC pan and the side wall of the compartment- Clothes hook in each cubicle at 1400mm above floor level
Sanitary Facilities: Building facilitats 375 people assume 50 / 50 spilt -c. 190 Male and 190 Female users.Ladies Toilets: - 2 x WC for 50 - 250 females, plus 1 for every additional (or part of 100)- 1 x WHB per toilet- 1 x handdryer per 2 x WHBNote: As a public assembly building enlarged toilet cubicle added with TGD M access and activity space clear of door swing (750mm x 750mm) outlined.Male Toilets: - 1 WC per 100 - 400 males- 1 Urinal per 50 males- 1 WHB per WC & 1 per 5 UrinalsWheelchair Acceessible:- 1,800 x 2,500mm minimum dimensions to enable 1800 x 1800mm wheelchair turning circle- See highlighted dimensions in drawing above
0
3080
Male & Female WC: Hatched area = Acitivity Space 300mm in front of cubicles & 300mm in front of WHB (minimum)Male Urinal -Recommended Activity spaces around Urinals outlined.Reference: Universal Design (6th Edition) Pages 2 -13 & 14
750
450
876
750
700 700
400
500
600
500
470
200
8 m²Male WC
9 m²Female WC
6 m²
WheelchairAccessibleUnisex WC
1800
1800Vertical Pull Rail
150
Horizontal Grab Rail
Vertical Grab Rail
320
Drop down Rail
350 350 350
Hand Dryer
Hand Dryer
892
Enlarged WC Cubicle
Disposable Bin
Shelf
Alarm Pull Cord
TGD B - Fire: All Bathrooms fitted with Mains Operated Smoke Alarms and Sprinkler systems
Walls:All Internal Walls Fire Rating 1 Hr12.5 Plasterboard x 2, Metal Stud 70; 12.5 Plasterboard x2
Hand Dryer
Urinals
2
006
1
004
800
Shelf - 800 -1,000mm min
740
Hand Rinse Basin 720- 740mm above FFL
Paper Dispenser
TP ARSD
Possible locations of:SD = Soap Dispenser TP = Toilet Paper DispenserAR = Alarm Reset Button
680
Vertical Grab Rail (Top) @ 1,400mm
65
65
95
Foul drainage pipes run from WHB (65mm diameter pipe) and Toilet (100mm diameter pipe) to stack system (100mm diameter pipe) which is held within Universal Column going down to Ground Floor. As pipes are below concrete floor and external they are insulated (PIR 100mm foil backed) to prevent freezing. (As per TGD H).
100
100
Note on FFL: Kingspan Raised Access Floor and Alpha Pedestal have not been included in this section
Reference: TGD M Diagram 16 - Heights of Various Fittings Wheelchair Accessible Unisex WC with Drainage Layout Walls:
All Internal Walls Fire Rating 1 Hr12.5 Plasterboard x 2, Metal Stud 70; 12.5 Plasterboard x2
Kingspan Multideck V146 Slim Deck Concrete Flooring
1407
Dis
h W
ashe
r O
ven
1600
Cas
h R
egis
ter
& D
rinks
C
olle
ctio
n
1,800 x 1,800mm Wheelchair Turning Circle
Ref
riger
ated
D
ispl
ay
1800
1800
20Counter for TraysNote: Must be <850mm above FFL
Coffee Dock Seating Area: Note: Minimum 1,350mm between tables to allow 2 people to pass comfortably. Plus 50mm minimum space between chair & wall to allow seating access. (References: Metric Handbook 6th Edition (P34-35). TGD M 1.5.5 Refreshment Facilities minimum requirements.
Kitchen Area
Seating Area
1376
Fire SafetyIn addition to the fire safety measures outlined in Ground Floor Plan note that there are 2x Class A extinguishers on 1st Floor both Located Close to ExitsIn Kitchen there is an additional Wet Chemical Fire Extinguisher
Scale
Checked by
Drawn byDateProject numberOrganisation Name
Project NameSheet Name
Client NameEmma Harrington
DT175-02 2018_19
Asindicated
Plans & Details -Toilets & Coffee Dock
01
DT175 02 TDSProject 2
Noel Brady 11/04/18
Checker006Linenhall
Dublin Institute ofTechnology Emma Harrington
1 : 201 First FFL (Toilets Layout)
1 : 10AA - Cross Section Unisex WC
1 : 251 First FFL (Coffee Dock Layout)
TDS PROJECT 3: Steel Community Building (Main Building & Building B) DT 175 ARCHITECTURAL TECHNOLOGY
Date: 07 November 2018 Page 1 Student Name: Emma Harrington Student Number: C17750321
Kingspan KS1000 RW Insulated Wall Panel – Installation Details
TDS PROJECT 3: Steel Community Building (Main Building & Building B) DT 175 ARCHITECTURAL TECHNOLOGY
Date: 07 November 2018 Page 1 Student Name: Emma Harrington Student Number: C17750321