Accendo - Retrofit Digital HID (DHID) Ballast Chart for Parking Lot Pole and High Bay Lighting...

Post on 18-Dec-2014

832 views 0 download

description

Retrofit your existing Metal Halide (MH) parking lot pole and high-bay lighting fixture with Digital HID (DHID) energy efficient upgrade ballasts. Applications include Retail, Auto Dealership, Airport Lighting, Factory, Distribution/Warehouse, and Public Space Lighting. For additional information on GloGreen Digital HID ballasts, please visit www.AccendoElectronics.com and www.AccendoElectronics.WordPress.com; or please do not hesitate to contact us at aborges@accendoelectronics.com

Transcript of Accendo - Retrofit Digital HID (DHID) Ballast Chart for Parking Lot Pole and High Bay Lighting...

Retrofit Digital HID (DHID) Ballast Chart for Parking Lot Pole and High-bay Lighting Fixture Applications

Retrofit Your Existing 1000W Metal Halide Parking Lot Pole Fixture With 600W DHID Ballast Applications include Retail, Auto Dealership, Warehouse/Factory, and Airport Lighting

Retrofit Recommendation: - 600W Metal Halide Lamp. - 600W DHID Ballast.

Existing 1000W MH lamp and Magnetic ballast mean lumens will quickly

drop below the initial lumens of the 600W DHID system w/ 95% efficacy.

Retrofit can be done inside existing ballast box or in a weather proof

enclosure if the ballast case temperature will not exceed 72°C/161.6°F.

Model

Input Watts

Voltage

Input Current

Dimensions (mm) LxWxH

B600-480M(D) 636 480 2.19A 322x138x90.5

Cost Savings:

1100W - 636W = 464W x 10 hrs x

365 days = 1693.6kW x $.10kWhr

= $169.36 Savings

Per Fixture Per Year.

With 4hrs at 50% Dimming:

232W x 4 hrs x 365 days x $.10kWhr

= $33.87 + $169.36

= $203.23 Savings

Per Fixture Per Year.

B600-480M(D)X 636 480 2.19A 322x138x90.5

B600-277M(D) 636 277 2.19A 319x138x90.5

B600-240M(D) 636 120-240 2.53A 266x138x90.5

M = non Dimming, D = Dimming , X = Pole Mount, Wet Listed

Retrofit Your Existing 400W Metal Halide Parking Lot Pole Fixture With 250W DHID Ballast Applications include Retail, Auto Dealership, Warehouse/Factory, and Airport Lighting

Retrofit Recommendation: - 250W Metal Halide Lamp. - 250W DHID Ballast.

Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop

below the initial lumens of the 250W DHID system w/ 95% efficacy. Retrofit

can be done inside existing ballast box or in a weather proof enclosure if the

ballast case temperature will not exceed 72°C/161.6°F.

Model

Input Watts

Voltage

Input Current

Dimensions (mm) LxWxH

B250-277M(D) 265 277 .95A 184x108x62

Cost Savings:

440W - 265W = 175W x 10 hrs x

365 days = 639kW x $.10kWhr

= $63.90 Savings

Per Fixture Per Year.

With 4hrs at 50% Dimming:

88W x 4 hrs x 365 days x $.10kWhr

= $12.85 + $63.90

= $76.75 Savings

Per Fixture Per Year.

B250-240M(D) 265 120-240 1.10A 184x108x62

M = non Dimming, D = Dimming

Retrofit Your Existing 400W Metal Halide Parking Lot Pole Fixture With 200W DHID Ballast Applications include Retail, Auto Dealership, Warehouse/Factory, and Airport Lighting

Retrofit Recommendation: - 200W or 250W MH Lamp. - 200/250W DHID Ballast.

Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop

below the initial lumens of the 200W DHID system w/ 95% efficacy. Retrofit

can be done inside existing ballast box or in a weather proof enclosure if the

ballast case temperature will not exceed 72°C/161.6°F.

Model

Input Watts

Voltage

Input Current

Dimension (mm) LxWxH

B200/250-277M(D) 214* 277 0.77A/0.95A 184x108x62

Cost Savings: 440W - 214W = 226W x 10 hrs x 365 days = 825kW x $.10kWhr = $82.50 Savings

Per Fixture Per Year.

With 4hrs at 50% Dimming:

113W x 4 hrs x 365 x $.10kWhr = $16.50 + $82.50 = $99.00 Savings Per Fixture Per Year.

B200/250-240M(D) 214* 120-240 0.89A/1.10A 184x108x62

*When run at 200W setting w/ 200W lamp - M = non Dimming, D = Dimming

Retrofit Your Existing 1000W Metal Halide High-bay Fixture With 575W DHID Ballast Applications include Factory, Distribution/Warehouse, Retail, and Public Space Lighting

Retrofit Recommendation: - 575W Metal Halide Lamp. - 575W DHID Ballast.

Existing 1000W MH lamp and Magnetic ballast mean lumens will quickly drop

below the initial lumens of the 575W DHID system w/ 95% efficacy. Retrofit can

be done inside ballast box if the ballast case temperature will not exceed

72°C/161.6°F; or install ballast outside fixture as shown in image above.

Model

Input Watts

Voltage

Input Current

Dimensions (mm) LxWxH

B575-277M(D) 606 277 2.19A 266x138x90.5

Cost Savings:

1100W - 606W = 494W x 10 hrs x

240 days = 1185.6 kW x $.10kWhr

= $118.56 Savings

Per Fixture Per Year.

With 4hrs at 50% Dimming:

247W x 4 hrs x 240 x $.10kWhr

= $23.71 + $118.56

= $142.27 Savings

Per Fixture Per Year.

B575-240M(D) 606 120-240 2.19A 319x138x90.5

M = non Dimming, D = Dimming

Retrofit Your Existing 400W Metal Halide High-bay Fixture With 250W DHID Ballast Applications include Factory, Distribution/Warehouse, Retail, and Public Space Lighting

Retrofit Recommendation: - 250W Metal Halide Lamp. - 250W DHID Ballast.

Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop

below the initial lumens of the 250W DHID system w/ 95% efficacy. Retrofit can

be done inside ballast box if the ballast case temperature will not exceed

72°C/161.6°F; or install ballast outside fixture as shown in image above.

Model

Input Watts

Voltage

Input Current

Dimensions (mm) LxWxH

B250-277M(D) 265 277 .95A 184x108x62

Cost Savings:

440W - 265W = 175W x 10 hrs x

240 days = 420kW x $.10kWhr

= $42.00 Savings

Per Fixture Per Year.

With 4hrs at 50% Dimming:

88W x 4 hrs x 240 x $.10kWhr

= $8.45 + $42.00

= $50.45 Savings

Per Fixture Per Year.

B250-240M(D) 265 120-240 1.10A 184x108x62

M = non Dimming, D = Dimming

Retrofit Your Existing 400W Metal Halide High-bay Fixture With 200W DHID Ballast Applications include Factory, Distribution/Warehouse, Retail, and Public Space Lighting

Retrofit Recommendation: - 200W or 250W MH Lamp. - 200/250W DHID Ballast.

Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop

below the initial lumens of the 200W DHID system w/ 95% efficacy. Retrofit can

be done inside ballast box if the ballast case temperature will not exceed

72°C/161.6°F; or install ballast outside fixture as shown in image above.

Model

Input Watts

Voltage

Input Current

Dimensions (mm) LxWxH

B200/250-277M(D) 214* 277 0.77A/0.95A 184x108x62

Cost Savings:

440W - 214W = 226W x10 hrs x

240 days = 542 kW x $.10kWhr

= $54.24 Savings

Per Fixture Per Year.

With 4hrs at 50% Dimming:

113W x 4 hrs x 240 x $.10kWhr

= $10.85 + $54.24

= $65.09 Savings

Per Fixture Per Year.

B200/250-240M(D) 214* 120-240 0.89A/1.10A 184x108x62

*When run at 200W setting w/ 200W lamp - M = non Dimming, D = Dimming

Accendo Electronics Ltd. 9-160 Gibson Dr. Markham, ON L3R 3K1 T: 905 475-2067 F: 905 470-0168 E: info@accendoelectronics.com