Accendo - Retrofit Digital HID (DHID) Ballast Chart for Parking Lot Pole and High Bay Lighting...
-
Upload
accendo-electronics-ltd -
Category
Technology
-
view
832 -
download
0
description
Transcript of Accendo - Retrofit Digital HID (DHID) Ballast Chart for Parking Lot Pole and High Bay Lighting...
Retrofit Digital HID (DHID) Ballast Chart for Parking Lot Pole and High-bay Lighting Fixture Applications
Retrofit Your Existing 1000W Metal Halide Parking Lot Pole Fixture With 600W DHID Ballast Applications include Retail, Auto Dealership, Warehouse/Factory, and Airport Lighting
Retrofit Recommendation: - 600W Metal Halide Lamp. - 600W DHID Ballast.
Existing 1000W MH lamp and Magnetic ballast mean lumens will quickly
drop below the initial lumens of the 600W DHID system w/ 95% efficacy.
Retrofit can be done inside existing ballast box or in a weather proof
enclosure if the ballast case temperature will not exceed 72°C/161.6°F.
Model
Input Watts
Voltage
Input Current
Dimensions (mm) LxWxH
B600-480M(D) 636 480 2.19A 322x138x90.5
Cost Savings:
1100W - 636W = 464W x 10 hrs x
365 days = 1693.6kW x $.10kWhr
= $169.36 Savings
Per Fixture Per Year.
With 4hrs at 50% Dimming:
232W x 4 hrs x 365 days x $.10kWhr
= $33.87 + $169.36
= $203.23 Savings
Per Fixture Per Year.
B600-480M(D)X 636 480 2.19A 322x138x90.5
B600-277M(D) 636 277 2.19A 319x138x90.5
B600-240M(D) 636 120-240 2.53A 266x138x90.5
M = non Dimming, D = Dimming , X = Pole Mount, Wet Listed
Retrofit Your Existing 400W Metal Halide Parking Lot Pole Fixture With 250W DHID Ballast Applications include Retail, Auto Dealership, Warehouse/Factory, and Airport Lighting
Retrofit Recommendation: - 250W Metal Halide Lamp. - 250W DHID Ballast.
Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop
below the initial lumens of the 250W DHID system w/ 95% efficacy. Retrofit
can be done inside existing ballast box or in a weather proof enclosure if the
ballast case temperature will not exceed 72°C/161.6°F.
Model
Input Watts
Voltage
Input Current
Dimensions (mm) LxWxH
B250-277M(D) 265 277 .95A 184x108x62
Cost Savings:
440W - 265W = 175W x 10 hrs x
365 days = 639kW x $.10kWhr
= $63.90 Savings
Per Fixture Per Year.
With 4hrs at 50% Dimming:
88W x 4 hrs x 365 days x $.10kWhr
= $12.85 + $63.90
= $76.75 Savings
Per Fixture Per Year.
B250-240M(D) 265 120-240 1.10A 184x108x62
M = non Dimming, D = Dimming
Retrofit Your Existing 400W Metal Halide Parking Lot Pole Fixture With 200W DHID Ballast Applications include Retail, Auto Dealership, Warehouse/Factory, and Airport Lighting
Retrofit Recommendation: - 200W or 250W MH Lamp. - 200/250W DHID Ballast.
Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop
below the initial lumens of the 200W DHID system w/ 95% efficacy. Retrofit
can be done inside existing ballast box or in a weather proof enclosure if the
ballast case temperature will not exceed 72°C/161.6°F.
Model
Input Watts
Voltage
Input Current
Dimension (mm) LxWxH
B200/250-277M(D) 214* 277 0.77A/0.95A 184x108x62
Cost Savings: 440W - 214W = 226W x 10 hrs x 365 days = 825kW x $.10kWhr = $82.50 Savings
Per Fixture Per Year.
With 4hrs at 50% Dimming:
113W x 4 hrs x 365 x $.10kWhr = $16.50 + $82.50 = $99.00 Savings Per Fixture Per Year.
B200/250-240M(D) 214* 120-240 0.89A/1.10A 184x108x62
*When run at 200W setting w/ 200W lamp - M = non Dimming, D = Dimming
Retrofit Your Existing 1000W Metal Halide High-bay Fixture With 575W DHID Ballast Applications include Factory, Distribution/Warehouse, Retail, and Public Space Lighting
Retrofit Recommendation: - 575W Metal Halide Lamp. - 575W DHID Ballast.
Existing 1000W MH lamp and Magnetic ballast mean lumens will quickly drop
below the initial lumens of the 575W DHID system w/ 95% efficacy. Retrofit can
be done inside ballast box if the ballast case temperature will not exceed
72°C/161.6°F; or install ballast outside fixture as shown in image above.
Model
Input Watts
Voltage
Input Current
Dimensions (mm) LxWxH
B575-277M(D) 606 277 2.19A 266x138x90.5
Cost Savings:
1100W - 606W = 494W x 10 hrs x
240 days = 1185.6 kW x $.10kWhr
= $118.56 Savings
Per Fixture Per Year.
With 4hrs at 50% Dimming:
247W x 4 hrs x 240 x $.10kWhr
= $23.71 + $118.56
= $142.27 Savings
Per Fixture Per Year.
B575-240M(D) 606 120-240 2.19A 319x138x90.5
M = non Dimming, D = Dimming
Retrofit Your Existing 400W Metal Halide High-bay Fixture With 250W DHID Ballast Applications include Factory, Distribution/Warehouse, Retail, and Public Space Lighting
Retrofit Recommendation: - 250W Metal Halide Lamp. - 250W DHID Ballast.
Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop
below the initial lumens of the 250W DHID system w/ 95% efficacy. Retrofit can
be done inside ballast box if the ballast case temperature will not exceed
72°C/161.6°F; or install ballast outside fixture as shown in image above.
Model
Input Watts
Voltage
Input Current
Dimensions (mm) LxWxH
B250-277M(D) 265 277 .95A 184x108x62
Cost Savings:
440W - 265W = 175W x 10 hrs x
240 days = 420kW x $.10kWhr
= $42.00 Savings
Per Fixture Per Year.
With 4hrs at 50% Dimming:
88W x 4 hrs x 240 x $.10kWhr
= $8.45 + $42.00
= $50.45 Savings
Per Fixture Per Year.
B250-240M(D) 265 120-240 1.10A 184x108x62
M = non Dimming, D = Dimming
Retrofit Your Existing 400W Metal Halide High-bay Fixture With 200W DHID Ballast Applications include Factory, Distribution/Warehouse, Retail, and Public Space Lighting
Retrofit Recommendation: - 200W or 250W MH Lamp. - 200/250W DHID Ballast.
Existing 400W MH lamp and Magnetic ballast mean lumens will quickly drop
below the initial lumens of the 200W DHID system w/ 95% efficacy. Retrofit can
be done inside ballast box if the ballast case temperature will not exceed
72°C/161.6°F; or install ballast outside fixture as shown in image above.
Model
Input Watts
Voltage
Input Current
Dimensions (mm) LxWxH
B200/250-277M(D) 214* 277 0.77A/0.95A 184x108x62
Cost Savings:
440W - 214W = 226W x10 hrs x
240 days = 542 kW x $.10kWhr
= $54.24 Savings
Per Fixture Per Year.
With 4hrs at 50% Dimming:
113W x 4 hrs x 240 x $.10kWhr
= $10.85 + $54.24
= $65.09 Savings
Per Fixture Per Year.
B200/250-240M(D) 214* 120-240 0.89A/1.10A 184x108x62
*When run at 200W setting w/ 200W lamp - M = non Dimming, D = Dimming
Accendo Electronics Ltd. 9-160 Gibson Dr. Markham, ON L3R 3K1 T: 905 475-2067 F: 905 470-0168 E: [email protected]