Using 3 mm Implants in Narrow Spaces

ANGULAR & LINEAR CORRECTIONS

3 Implants #7 ▪ #10 ▪ #11 Magnetic Guide Posts & Open Sleeves Generation ll Bending Tool Software Analysis

QUATE 2.2013

Invivo5 Anatomage

DIAGNOSTIC Guide

fabrication not shownThe initial treatment plan was:

▪ to place a 3 mm implant in the #7 position ▪ to place a 4 mm implant in the #11 position▪ with a mesial cantilever in the #10 position.However a cantilever would not fit on a 3 mm implant.Therefore 2 different size guide sleeves were used for the final treatment plan.

`

Initial Treatment PlanDIAGNOSTIC guide with two guide sleeves in proposed sites :

2 mm guide sleeve #7 site ▪ 3 mm guide sleeve #11 with mesial cantilever

Preview of Pre-op Corrections

#7LINEAR CORRECTION

1 mm offset toward the buccal

3 mm offset toward the buccal

ANGULAR CORRECTION

12° bend toward the distal

#11LINEAR CORRECTION

PRE OPERATIVE

Software Evaluation

Invivo5Anatomage

`

#7 INITIAL ALIGNMENT in 2 planes: mesio-distal & bucco-lingual

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

`

# 7 LINEAR ALIGNMENT

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

cross sectional view tangential view

Virtual implant in position.# 7

Invivo5Anatomage

cross sectional view

3 mm post X 1 mm offset correction toward the buccal requiredLINEAR CORRECTION# 7

Invivo5Anatomage

`

1 mm offset is measured & requires a 1 mm offset placement toward the buccal

# 7

`

3 mm X 1 mm Offset Magnetic Guide Post required for #7 buccal correction.

#10 ALIGNMENT

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

cross sectional view tangential view

# 10 did not initially have a guide sleeve in the DIAGNOSTIC guide because originally a mesial cantilever was anticipated from the implant in the #11 position.

Invivo5Anatomage

# 10

`

3 mm Straight Magnetic Guide Post for #10

#11 INITIAL ALIGNMENTof virtual implant and guide sleeve

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

cross sectional view axial view

volumetric view tangential view

LINEAR CORRECTION: 3 mm offset ANGULAR CORRECTION: 12° bend toward the distal

Invivo5Anatomage

#11

cross sectional view axial view

tangential view

#11 LINEAR CORRECTION

The guide post/sleeve must be moved 3 mm toward the buccal.

Invivo5Anatomage

cross sectional view tangential view

#11 LINEAR CORRECTION The guide post/sleeve must be moved 3 mm toward the buccal.

3 mm offset guide post is required for correction

Invivo5Anatomage

tangential

SOFTWARE GRID

each square: 5 X 5 mm

each side of the square: 5 mm

center mark is 2.5 mm

Understanding Grid Measurements

2.5 mm

5 mm

Invivo5

`

#11 3 mm offset is measured using the software grid Invivo5

3 mm

tangential view

#11 ANGULAR CORRECTION 12° bend toward the distal is needed.

Invivo5Anatomage

`

A 3 mm offset guide post is required for #11 correction

`

12°

3 mm X 3 mm offset guide post bent 12° toward the distal

Magnetic Guide Posts Open Guide Sleeves

Fabrication of SURGICAL Guide

`

Corrected Magnetic Guide Posts in castA hole was drilled at the #10 site parallel to #11 (5.0 mm apart on center).

5.0 mm apart on center

`

Open Guide Sleeves placed on Magnetic Guide Posts and positioned with cleats to the palatal.

`

Triad® Gel is added to form the SURGICAL guide in two sections

Review of Pre-op Corrections

#7LINEAR CORRECTION

1 mm offset toward the buccal

NO CORRECTION

3 mm offset toward the buccal

ANGULAR CORRECTION

12° bend toward the distal

#11LINEAR CORRECTION

#10

A direction indicator is used in #7 site to check alignment after the 2 mm drill is used.

# 7 3mm X 13 mm implant placement.

`

2 mm direction indicator is placed in the #11 position

`

Final placement for implants in #10 and #11 positions.

`

Atlantis abutments are inserted.

`

Final restorations

1 - 3/32” Drill

1 – 2 mm Drill or #46 Drill

1 - 2 mm Guide Post

1 – 3 mm Guide Post

1 – 2 mm Guide Sleeve

1- 3 mm Guide Sleeve

1 - 3 mm Magnetic Guide Post

1 - 3 X 3.0 mm Offset Magnetic Guide Post

1 - 3 X 1.0 mm Offset Magnetic Guide Post

3 - 3 mm Open Guide Sleeve

Triad® Gel

Generation ll Bending Tool

Guide Right™

Products used in this presentation

1.800.314.0065 • www.deplaque.com

In-office or lab fabrication

Evaluate with 2D & 3D imaging

Allows linear and angular correction

Enables precision implant placement

Cost effective

A System of Components

for the fabrication and correction of DIAGNOSTIC & SURGICAL guides in one or two dimensions

1.800.314.0065 • www.deplaque.com

Guide Right™ Surgical Guide System

Start With Precision. Place With Confidence.™

1.800.314.0065 • www.deplaque.com

fabricate ▪ evaluate ▪ correct ▪ verify ▪ place

DéPlaque