10 use of 3 mm implants in narrow space angular & linear corrections

37
Using 3 mm Implants in Narrow Spaces ANGULAR & LINEAR CORRECTIONS 3 Implants #7 #10 #11 Magnetic Guide Posts & Open Sleeves Generation ll Bending Tool Software Analysis QUATE 2.2013 I nvi vo5 Anatomage

Transcript of 10 use of 3 mm implants in narrow space angular & linear corrections

Page 1: 10 use of 3 mm implants in narrow space angular & linear corrections

Using 3 mm Implants in Narrow Spaces

ANGULAR & LINEAR CORRECTIONS

3 Implants #7 ▪ #10 ▪ #11 Magnetic Guide Posts & Open Sleeves Generation ll Bending Tool Software Analysis

QUATE 2.2013

Invivo5 Anatomage

Page 2: 10 use of 3 mm implants in narrow space angular & linear corrections

DIAGNOSTIC Guide

fabrication not shownThe initial treatment plan was:

▪ to place a 3 mm implant in the #7 position ▪ to place a 4 mm implant in the #11 position▪ with a mesial cantilever in the #10 position.However a cantilever would not fit on a 3 mm implant.Therefore 2 different size guide sleeves were used for the final treatment plan.

Page 3: 10 use of 3 mm implants in narrow space angular & linear corrections

`

Initial Treatment PlanDIAGNOSTIC guide with two guide sleeves in proposed sites :

2 mm guide sleeve #7 site ▪ 3 mm guide sleeve #11 with mesial cantilever

Page 4: 10 use of 3 mm implants in narrow space angular & linear corrections

Preview of Pre-op Corrections

#7LINEAR CORRECTION

1 mm offset toward the buccal

3 mm offset toward the buccal

ANGULAR CORRECTION

12° bend toward the distal

#11LINEAR CORRECTION

Page 5: 10 use of 3 mm implants in narrow space angular & linear corrections

PRE OPERATIVE

Software Evaluation

Invivo5Anatomage

Page 6: 10 use of 3 mm implants in narrow space angular & linear corrections

`

#7 INITIAL ALIGNMENT in 2 planes: mesio-distal & bucco-lingual

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

Page 7: 10 use of 3 mm implants in narrow space angular & linear corrections

`

# 7 LINEAR ALIGNMENT

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

Page 8: 10 use of 3 mm implants in narrow space angular & linear corrections

cross sectional view tangential view

Virtual implant in position.# 7

Invivo5Anatomage

Page 9: 10 use of 3 mm implants in narrow space angular & linear corrections

cross sectional view

3 mm post X 1 mm offset correction toward the buccal requiredLINEAR CORRECTION# 7

Invivo5Anatomage

Page 10: 10 use of 3 mm implants in narrow space angular & linear corrections

`

1 mm offset is measured & requires a 1 mm offset placement toward the buccal

# 7

Page 11: 10 use of 3 mm implants in narrow space angular & linear corrections

`

3 mm X 1 mm Offset Magnetic Guide Post required for #7 buccal correction.

Page 12: 10 use of 3 mm implants in narrow space angular & linear corrections

#10 ALIGNMENT

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

Page 13: 10 use of 3 mm implants in narrow space angular & linear corrections

cross sectional view tangential view

# 10 did not initially have a guide sleeve in the DIAGNOSTIC guide because originally a mesial cantilever was anticipated from the implant in the #11 position.

Invivo5Anatomage

# 10

Page 14: 10 use of 3 mm implants in narrow space angular & linear corrections

`

3 mm Straight Magnetic Guide Post for #10

Page 15: 10 use of 3 mm implants in narrow space angular & linear corrections

#11 INITIAL ALIGNMENTof virtual implant and guide sleeve

cross sectional view axial view

volumetric view tangential view

Invivo5Anatomage

Page 16: 10 use of 3 mm implants in narrow space angular & linear corrections

cross sectional view axial view

volumetric view tangential view

LINEAR CORRECTION: 3 mm offset ANGULAR CORRECTION: 12° bend toward the distal

Invivo5Anatomage

#11

Page 17: 10 use of 3 mm implants in narrow space angular & linear corrections

cross sectional view axial view

tangential view

#11 LINEAR CORRECTION

The guide post/sleeve must be moved 3 mm toward the buccal.

Invivo5Anatomage

Page 18: 10 use of 3 mm implants in narrow space angular & linear corrections

cross sectional view tangential view

#11 LINEAR CORRECTION The guide post/sleeve must be moved 3 mm toward the buccal.

3 mm offset guide post is required for correction

Invivo5Anatomage

Page 19: 10 use of 3 mm implants in narrow space angular & linear corrections

tangential

SOFTWARE GRID

each square: 5 X 5 mm

each side of the square: 5 mm

center mark is 2.5 mm

Understanding Grid Measurements

2.5 mm

5 mm

Invivo5

Page 20: 10 use of 3 mm implants in narrow space angular & linear corrections

`

#11 3 mm offset is measured using the software grid Invivo5

3 mm

Page 21: 10 use of 3 mm implants in narrow space angular & linear corrections

tangential view

#11 ANGULAR CORRECTION 12° bend toward the distal is needed.

Invivo5Anatomage

Page 22: 10 use of 3 mm implants in narrow space angular & linear corrections

`

A 3 mm offset guide post is required for #11 correction

Page 23: 10 use of 3 mm implants in narrow space angular & linear corrections

`

12°

3 mm X 3 mm offset guide post bent 12° toward the distal

Page 24: 10 use of 3 mm implants in narrow space angular & linear corrections

Magnetic Guide Posts Open Guide Sleeves

Fabrication of SURGICAL Guide

Page 25: 10 use of 3 mm implants in narrow space angular & linear corrections

`

Corrected Magnetic Guide Posts in castA hole was drilled at the #10 site parallel to #11 (5.0 mm apart on center).

5.0 mm apart on center

Page 26: 10 use of 3 mm implants in narrow space angular & linear corrections

`

Open Guide Sleeves placed on Magnetic Guide Posts and positioned with cleats to the palatal.

Page 27: 10 use of 3 mm implants in narrow space angular & linear corrections

`

Triad® Gel is added to form the SURGICAL guide in two sections

Page 28: 10 use of 3 mm implants in narrow space angular & linear corrections

Review of Pre-op Corrections

#7LINEAR CORRECTION

1 mm offset toward the buccal

NO CORRECTION

3 mm offset toward the buccal

ANGULAR CORRECTION

12° bend toward the distal

#11LINEAR CORRECTION

#10

Page 29: 10 use of 3 mm implants in narrow space angular & linear corrections

A direction indicator is used in #7 site to check alignment after the 2 mm drill is used.

Page 30: 10 use of 3 mm implants in narrow space angular & linear corrections

# 7 3mm X 13 mm implant placement.

Page 31: 10 use of 3 mm implants in narrow space angular & linear corrections

`

2 mm direction indicator is placed in the #11 position

Page 32: 10 use of 3 mm implants in narrow space angular & linear corrections

`

Final placement for implants in #10 and #11 positions.

Page 33: 10 use of 3 mm implants in narrow space angular & linear corrections

`

Atlantis abutments are inserted.

Page 34: 10 use of 3 mm implants in narrow space angular & linear corrections

`

Final restorations

Page 35: 10 use of 3 mm implants in narrow space angular & linear corrections

1 - 3/32” Drill

1 – 2 mm Drill or #46 Drill

1 - 2 mm Guide Post

1 – 3 mm Guide Post

1 – 2 mm Guide Sleeve

1- 3 mm Guide Sleeve

1 - 3 mm Magnetic Guide Post

1 - 3 X 3.0 mm Offset Magnetic Guide Post

1 - 3 X 1.0 mm Offset Magnetic Guide Post

3 - 3 mm Open Guide Sleeve

Triad® Gel

Generation ll Bending Tool

Guide Right™

Products used in this presentation

1.800.314.0065 • www.deplaque.com

Page 36: 10 use of 3 mm implants in narrow space angular & linear corrections

In-office or lab fabrication

Evaluate with 2D & 3D imaging

Allows linear and angular correction

Enables precision implant placement

Cost effective

A System of Components

for the fabrication and correction of DIAGNOSTIC & SURGICAL guides in one or two dimensions

1.800.314.0065 • www.deplaque.com

Page 37: 10 use of 3 mm implants in narrow space angular & linear corrections

Guide Right™ Surgical Guide System

Start With Precision. Place With Confidence.™

1.800.314.0065 • www.deplaque.com

fabricate ▪ evaluate ▪ correct ▪ verify ▪ place

DéPlaque