2
49 Solar Power Conditioning Unit SOLAR PCU BASED INSTALLATION DIAGRAM OR PV GENERATOR Load Storage Battery POWER CONDITIONING UNIT Grid Generator GENERATION PROFILE PWM Range - Single Phase: 600 VA/24V It is an integrated system consisting of a Solar Charge Controller, Inverter and a Grid charger. It has inbuilt intelligence to utilize the solar power on priority. Working Principle Solar PCU converts energy from solar panel as the first priority and incase the solar power can not support the load grid power is used to charge the battery and supply load. Features • Pure sine wave output In-built heavy duty Solar charge Controller • Excellent overload capabilities • Optimal battery protection • Best reliability High reliability with Minimal maintenance Grid charging enable disable option • Solar and Grid charging current sharing for maximum solar usage • User set-able Solar Mains Battery (SMB) and Solar Battery Mains (SBM) operations Electronic Protection updates • Battery low protection • Battery over voltage shutdown Over temperature and overload protection • Short circuit protection Reverse polarity protection by internal fuse Acoustic alarm in various warning conditions Displays Display showing PV & Inverter output • LCD showing various input and output parameters such as •Output voltage •load •input voltage •battery voltage •PV voltage •current with cumulative solar energy. Operation Short circuit , over load & over heating protection Automatic Charger Restart Time after High Current Remote Monitoring Software Remote monitoring through RS232, Ethernet, GSM, GPRS Certification & patents • IEC61683, IEC60068-2-1,2,14,30,31 (N/A for 6H24); IEC62093 certification Single Phase PWM Range

Transcript of Solar Power Conditioning Unit

Page 1: Solar Power Conditioning Unit

49

Solar Power Conditioning Unit

SOLAR PCU BASED INSTALLATION DIAGRAM

OR

PV GENERATOR Load

Storage Battery

POWER

CONDITIONING UNIT

GridGenerator

GENERATION PROFILE

PWM Range - Single Phase: 600 VA/24VIt is an integrated system consisting of a Solar Charge Controller, Inverter and a Grid charger. It has inbuilt intelligence to utilize the solar power on priority. Working Principle Solar PCU converts energy from solar panel as the first priority and incase the solar power can not support the load grid power is used to charge the battery and supply load.

Features• Pure sine wave output• In-built heavy duty Solar charge Controller• Excellent overload capabilities• Optimal battery protection• Best reliability• High reliability with Minimal maintenance• Grid charging enable disable option• Solar and Grid charging current sharing for maximum solar usage• User set-able Solar Mains Battery (SMB) and Solar Battery Mains (SBM) operationsElectronic Protection updates• Battery low protection• Battery over voltage shutdown• Over temperature and overload protection• Short circuit protection• Reverse polarity protection by internal fuse

• Acoustic alarm in various warning conditionsDisplays• Display showing PV & Inverter output• LCD showing various input and output parameters such as •Output voltage •load •input voltage •battery voltage •PV voltage •current with cumulative solar energy.Operation• Short circuit , over load & over heating protection• Automatic Charger Restart Time after High CurrentRemote Monitoring Software• Remote monitoring through RS232, Ethernet, GSM, GPRSCertification & patents• IEC61683, IEC60068-2-1,2,14,30,31 (N/A for 6H24); IEC62093 certification

Single Phase PWM Range

Page 2: Solar Power Conditioning Unit

Type Single Phase Solar Power Conditioning Unit

Technology DSP Based PWM Technology

Ratings 600VA

PV Charge Controller Rating 600Wp

Model No. PCU 6H24

Power device MOSFETs

INVERTER

INPUT PARAMETERS

Nominal I/P Voltage 24V

Input Voltage Range 22V-30V±0.4V

Low Battery cut off 22.6V ± 0.4V

High Battery shutdown NA

No load shutdown enable

Output Waveform Pure Sine Wave

Overload 200% for 8seconds

THD (on Linear Load) <5%

Power usage Priority From Photovoltaic Array

Crest Factor >3:1

Grid power usage Over Current, Battery over Charge Protection, PV/Battery Reverse Polarity, Reverse Current Flow, High Temperature

GRID CHARGER

Grid I/P Voltage Range WW-175-285

NW-190-265±10V

Charging Current 13A±1A

SOLAR CHARGE CONTROLLER

Type Series Regulator Common Negative

Maximum I/P PV Voltage 25V Per 12V Solar Panel

Solar Array Single Array

Charging Current Imax. > 20A

Bulk Voltage 28.8V±0.4V

Adjustable Bulk Voltage 53V-60V

Transition from float to bulk Below float level for a cumulative period of 1 hour

Float Voltage 27V±0.4V

Protection Over Current, Battery over Charge Protection, PV/Battery Reverse Polarity, Reverse Current Flow, High Temp.

Automatic Charger Restart Time 3.5 Minutes

after High Current

Cooling Forced air

OTHER SPECIFICATIONS

Indications Indications for PV voltage, Battery Voltage, Output Voltage, Output Frequency,

Output Current, Charging Current, Charging Mode, High Temp., High Current, Array Reverse Polarity etc.

Operating Temp. 0°C to + 45°C

Storage Temp. 0°C to + 55°C

Acoustic Noise < 60dB

Relative Humidity 0-95% Non-Condensing

Dimension 245x450x356 mm

Weight 17.6 kg

50

Solar Power Conditioning UnitSingle Phase PWM Range

TECHNICAL SPECIFICATIONS