DAB TRANSMITTER P75-01/DAB Liquid cooled · DAB and Tv standards worldwide. An additional ALC board...

6
TECHNICAL SPECIFICATIONS www.syes.eu Features and specifications subject to change without notice Technical specifications DAB TRANSMITTER Up to 1500W rms DAB transmitter with liquid cooling system in a compact solution made by one/two drivers in redundancy driver and one 1500W amplifier in 44U cabinet. General features VHF-III frequency band (174 to 230 MHz or 160 to 260 MHz*) Fully compliant with standard TS 102 428 - (DAB/DAB+/DMB) transmission High efficiency & Compact size Configurable as Transmitter or Repeater* High reliability: HPA power supplies in 2+1 configuration Inputs: -dual ETI (radio) -Ethernet EDI: 2xGBE(Electrical) + 1xSFP(optical/electrical)* -Sat* (DVB-S/S2-multistr.-CAM slot) -off-air broadcast* (RF) Fully qualified for SFN - Hitless input switching, Frequency agile - “static” or “adaptive” pre-correction (both linear and non-linear) Broadband standardized design Frequency ref: -built-in high stability OCXO, -input for optional external source -Built-in GPS receiver Single phase voltage supply - High efficiency Front-panel display & SNMP / HTTP for direct & remote equipment control. Easy SW/FW update –remote (Ethernet) –local (USB flash key) –ASI stream (OTA service) P75-01/DAB Liquid cooled

Transcript of DAB TRANSMITTER P75-01/DAB Liquid cooled · DAB and Tv standards worldwide. An additional ALC board...

  • TECHNICAL SPECIFICATIONS

    www.syes.eu Features and specifications subject to change without notice

    Technical specifications

    DAB TRANSMITTER

    Up to 1500W rms DAB transmitter with liquid cooling system in a compact solution made by one/two drivers in redundancy driver and one 1500W amplifier in 44U cabinet.

    General features VHF-III frequency band (174 to 230 MHz or 160 to 260 MHz*) Fully compliant with standard TS 102 428 - (DAB/DAB+/DMB)

    transmission High efficiency & Compact size Configurable as Transmitter or Repeater* High reliability: HPA power supplies in 2+1 configuration Inputs:

    -dual ETI (radio) -Ethernet EDI: 2xGBE(Electrical) + 1xSFP(optical/electrical)* -Sat* (DVB-S/S2-multistr.-CAM slot) -off-air broadcast* (RF)

    Fully qualified for SFN - Hitless input switching, Frequency agile - “static” or “adaptive” pre-correction (both

    linear and non-linear) Broadband standardized design Frequency ref:

    -built-in high stability OCXO, -input for optional external source -Built-in GPS receiver

    Single phase voltage supply - High efficiency Front-panel display & SNMP / HTTP for direct & remote

    equipment control. Easy SW/FW update

    –remote (Ethernet) –local (USB flash key)

    –ASI stream (OTA service)

    P75-01/DAB Liquid cooled

  • TECHNICAL SPECIFICATIONS

    www.syes.eu Features and specifications subject to change without notice

    Technical specifications

    Top-level output power in compact size: up to 20kW rms per cabinet, with integrated cooling circulation system to simplify equipment installation and handling. Excellent performance matches with ease of operation and reliability, providing the ideal solution for high-power TV stations. Transmitter configurations are based on a combination of high gain amplifiers, P75 type, directly fed by the exciter. Each module includes redundancy in power supply (2+1). Concerning the whole transmitter, the choice of redundancy configurations includes dual drive (exciter std-by), passive reserve (1+1 or n+1) and active reserve. The equipment parts are installed in 19” cabinets, featuring a remarkably short overall depth.

    Coolant circulation is carried out by redundant pumps, typically integrated in the transmitter cabinet, connected to outdoor heat exchanger(s).Coolant flow, as well as fan speed of the heat exchanger, are adaptively controlled according to the actual cooling needs. The coolant type, non-toxic and easy to dispose of, also allows for long service intervals and optimally preserves the cooling circuit parts. Equipment operation is supervised by the SyES designed control unit. With a large ouch screen display for an easy use

    The core of the transmitter is the multimode, multistandard driver named PCM totally designed and manufactured by SyES. This allows the transmitter to work both analogue and digital and with almost all existing Radio DAB and Tv standards worldwide. An additional ALC board (optional) provides the ability of PCM to drive also third parties amplifiers

    Finally on driver measures of MER and shoulder are done: this allows the performance of the adaptive linear and non linear precorrection based on sampling of the signal and on the optimization of RF performances with a step by step tracking algorithm

    Ambient air for Hot swappable

    power supplies Liquid cooled heat sink: liquid cooled plate to dissipate heat coming from power

    supplies (from the lower part of the amplifier) and from the final stages (from

    the upper part of the amplifier

    Hot coolant to the heat exchanger

    Cold coolant from heat exchanger

    P75 liquid cooled amplifier : cooling principle

  • TECHNICAL SPECIFICATIONS

    www.syes.eu Features and specifications subject to change without notice

    Technical specifications

    Cabinet top:

    -IN/OUT Connections

    (Standard solution, different

    available)

    -Cooling fan /extractor (OPT)

    Probe panel with emergency

    button

    Transmitter control logic

    SyES model UCA

    Transmitter exciter/driver

    SyES model PCM

    (Dual driver solution)

    Transmitter RF amplifier

    SyES model P75

    Transmitter cooling drawer

    with two pumps and

    expansion vessel inside,

    mimic panel and pressure

    gauge in front panel

    Transmitter Power

    distribution

    FRONT LAYOUT

    600 mm

    21

    00

    mm

  • TECHNICAL SPECIFICATIONS

    www.syes.eu Features and specifications subject to change without notice

    Technical specifications

    TECHNICAL FEATURES

    GENERAL

    RF – Output Power – before filter (Wrms) 1600 @ 28 dB MER 1500 @ 30 dB MER 1200 @ 33 dB MER

    Mains Voltage 230Vac ±15% 47÷63Hz Single phase (autorange) 400Vac ± 15% 47÷63 Hz Three phase (3Ph+N+Pe)

    Power consumption (W) 3600

    Cooling Liquid cooling system: two pump in redundancy, close vessel type, 8l/min each amplifier. With external heat exchanger

    Size Width (mm) 600

    Height (mm) 2300

    Depth (mm) 1100

    Weight (kg) 335

    BB INPUTS DAB

    ref. standards TS 102 428

    RF channel width 1.536 MHz blocks

    ASI/ETI inputs 2xASI/ETI (BNC f, 75W) – seamless/hitless switching (SFN)

    IP input 2xGBE (ProMPEG Cop3) – Electrical + 1XSFP GBE – Opt./Elec.*

    SATELLITE RECEIVER

    SatTV standard DVB-S — DVB-S2 – EN300421

    Frequency range 950 – 2150 MHz

    Signal level -65 to -25 dBm

    Connector – Cond. Access SMA f – CAM slot

    LNB control available, through RF input

    PS, polarity / band selection: by standard 13/18VDC and 22kHz signalling

    MONITORING AND CONTROLRF

    Monitoring Connectors FWD/REF: SMA female , 50 W

    Local Control front panel (keys/display/USB port) / standard web browser

    Remote Control Netw. Mgmt.

    web browser / SNMP agent – upgrade also through ASI TS (OTA)

    Direct signalling IEC 60864-1

    FREQUENCY REFERENCES

    Built-in ref. Frequency 10 MHz OCXO

    Stability time: max ±10-7 /year – temperature: max ±2.5 10-8 (-20° to 70°C)

    Ext. ref. Frequency 10 MHz – 1pps

    Level 1 Vpp (0.7 to 1.4 V)

    VCO tuning step 1 Hz

    OPERATING CONDITIONS

    Operating temp. range 0° to 50°C*

    Max rel. air humidity 95% @ 30°C, no condensation

    Max altitude 4000 m a.s.l.

    Safety EN 60215 (IEC 215)

    OTHER FEATURES

    Hitless switching between two of the input signals

    BER and CRC analysis for Hitless switching

    Parameters configuration via ETI: ETI-all (Modulation parameters+ optional from MNSC), EIT-Modulation (only modulation parameters), Local (for manual configuration)

    Automatic analysis and check of ETI Input signal: NI(G703), NA5376(G704), NA5592(G704)

    Measurement and visualization of network delay parameters:

    o network compensation delay

    o Current total delay

    o frame zero delay

    Transmitter delay and delay offset comparison ,analysis and configuration (can be set with 100ns step)

  • TECHNICAL SPECIFICATIONS

    www.syes.eu Features and specifications subject to change without notice

    Technical specifications

    www.syes.eu Features and specifications subject to change without notice

    jitter measurement over network compensation delay(Min and Max network Jitter delay)

    Automatic analysis and check of SSTC Parameters

    o Sub channel ID

    o Start address

    o Type and protection level

    o Number of CU

    o Subchannel bitrate

    Adaptive automatic pre-correction, both linear and nonlinear.

    Can store and load up to 10 different pre-calibrated curves for an easy adaptation to external filtering

    Adaptive pre-correction can be set on-off and run one time, scheduled or continuous

    MER measurement

    Can measure and store up to 7 different configuration. This can be saved ant transferred to other items via USB key or via WEB /SNMP

    Internal GPS high precision receiver for on board synchronization

    High stability OCXO max ±10-7sec /year- temperature: max ±2.5 10-8 (-20° to 70°C), VCO tuning step: 1Hz

    holdover function for loss of 10 MHz external signal or of GPS signal

    Standard transmitter protection (over voltage, over current, over temperature, overload and similar), ROS protection with threshold level selectable

    Standard and advanced Echo cancellation (for gap filler configuration)

    System Block diagram (Output filter optional)

    No. 1 PA (P75 type)

  • TECHNICAL SPECIFICATIONS

    www.syes.eu Features and specifications subject to change without notice

    Technical specifications

    DETAIL ON P75 LIQUID COOLED AMPLIFIER

    P75 amplifier front view Detail on 3 internal power supply hot pluggable 2+1 config.

    P75 amplifier rear view with plug in and no spill connectors

    Amplifier Block diagram

    SY.E.S. S.r.l. Via Zanella, 21- 20851 Lissone (MB) Italy - Tel.+39.039.9897.1 - [email protected]

    mailto:[email protected]