6/0
Contents 0 6 - Pendant control stations and controllers
Pendant control stations with intuitive operationSelection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/2
Double insulated, for control circuits
Complete stations “ready for use”, “Pistol grip”, type XAC A . . . . . . . . page 6/5 Complete stations “ready for use”, type XAC D . . . . . . . . . . . . . . . . . page 6/9
Double insulated, for power circuits (direct switching)
Complete stations “ready for use”, type XAC D . . . . . . . . . . . . . . . . .page 6/11
Double insulated, for control or power circuits
Empty enclosures, type XAC D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/12Separate components and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . page 6/12Variable composition stations, factory assembled . . . . . . . . . . . . page 6/17
Pendant control stationsSelection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/2
Double insulated, type XAC A, for control circuits
Complete stations “ready for use” . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/19Empty enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/23Separate components and spare parts . . . . . . . . . . . . . . . . . . . . . . . page 6/24Variable composition stations, factory assembled . . . . . . . . . . . . page 6/33
Double insulated, type XAC B or metal, type XAC M (1)
Complete stations “ready for use”, type XAC B, for control circuits . . page 6/35Complete stations “ready for use”, type XAC B, for power circuits . . . page 6/37Empty enclosures, type XAC B, for control or power circuits . . . . . . . page 6/39Empty enclosures, type XAC B or XAC M, for control circuits . . . . . . . page 6/41Separate components and spare parts . . . . . . . . . . . . . . . . . . . . . . . page 6/42Variable composition stations, factory assembled . . . . . . . . . . . . . . . page 6/59
Double insulated, type XAC F, for control circuits (1)
Empty enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/61Variable composition stations, factory assembled . . . . . . . . . . . . . . . page 6/65
(1) XAC M and XAC F: products for maintenance purposes only.
b
v
v
b
v
b
v
v
v
b
v
v
v
v
b
v
v
v
v
v
v
b
v
v
Contents 0
6/0
6
6/1
ControllersSelection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6/66
Controllers for “light hoisting” applications, type XKB
Controllers XKB A with predefi ned, non modifi able schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/72Controllers XKB E with variable composition schemes,factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/72Separate components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/75
Controllers for “medium hoisting” applications, type XKD F
Controllers with variable composition schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/78Separate components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/83
Controllers for “heavy hoisting” applications, type XKM
Controllers XKM A and XKM B with variable composition schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/86Controllers XKM C with variable composition schemes, factory assembled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/93Separate components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/95
Potentiometers for controllers
For standard applications, type XKZ A . . . . . . . . . . . . . . . . . . . . . . . page 6/100For applications requiring an extended “neutral zone”, types XKB Z and XKD Z . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6/101
b
v
v
v
b
v
v
b
v
v
v
b
v
v
6
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
6/2
Pendant control stations 6 Complete stations “ready for use” and variable composition stations
Complete stations “ready for use”Applications Control circuits
Simple hoisting: 1 movement Handling-hoisting: 2 movements
Motor control
Number of operators 2 (2-directional)
2 2 4 4
Enclosure material Polypropylene Polypropylene Polypropylene Polyester Polypropylene PolyesterPendant station type reference
XAC A XAC D XAC A XAC B XAC A XAC BPage(s) 6/5 6/9 6/9 6/35 6/20 6/35
Variable composition stationsApplications Control circuitsNumber of cut-outs 1 or 2 2, 3, 4, 5, 6, 8 or 12 2, 3, 4, 6, 8 or 12 in 1 row or 2
rows of 6
Equipment Emergency stop (front mounted) Contact blocks for or 2 speeds
b
b
PushbuttonsSelector/key switchesPilot lightsEmergency stop (front or base mounted)WobblesticksContact blocks for or 2 speeds
bbbb
bb
PushbuttonsSelector/key switchesPilot lightsEmergency stop (front or base mounted)WobblesticksContact blocks for or 2 speeds
bbbb
bb
Enclosure material Polypropylene Polypropylene PolyesterPendant station type reference
XAC D XAC A XAC BPage(s) 6/2 and 6/3 6/23 to 6/29 6/39 to 6/54
Single-speed
2-speed
Emergencystop
Single-speed
2-speed
Emergencystop
Selectionguide 6
1
2
3
4
5
6
7
8
9
10
6/3
6
Power circuitsHandling-hoisting: 3 movements Simple hoisting: 1 movement Handling-hoisting:
2 movements 3 movements
6 6 8 8 (2-directional)
2 4 6
Polypropylene Polyester Polypropylene Polyester Polypropylene Polyester Polyester Polyester
XAC A XAC B XAC A XAC B XAC D XAC B XAC B XAC B6/20 6/35 6/2 6/35 6/ 6/37 6/37 6/38
Power circuits4 or 8 Up to 30 1 or 2 2, 3, 4, 6, 8 or 12 in 2 rows of 6
Products for maintenance purposes only Products for maintenance purposes only
PushbuttonsSelector/key switchesPilot lightsEmergency stop (front or base mounted)WobblesticksContact blocks for or 2 speeds
bbbb
bb
PushbuttonsSelector/key switchesPilot lightsEmergency stop (front or base mounted)WobblesticksContact blocks for or 2 speeds
bbbb
bb
Emergency stop (front mounted) Contact blocks for or 2 speeds
bb
PushbuttonsSelector/key switchesPilot lightsEmergency stop (front or base mounted)WobblesticksContact blocks for or 2 speeds
bbbb
bb
Aluminium Polyester Polypropylene Polyester
XAC M XAC F XAC D XAC B6/4 6/6 6/2 and 6/3 6/37 to 6/54
6
1
2
3
4
5
6
7
8
9
10
6/4
Current in A
Characteristics 6
EnvironmentConformity to standards EN/IEC 60947-5-
EN/IEC 60204-32, UL 508, CSA C22-2 n° 4EN/IEC 60947-5-5 and EN/ISO 3850: 2006 for versions with trigger action Emergency stop
Product certifications UL type 4X A600-Q600, CSA type 4 A600-Q600
Protective treatment Standard version “TH”
Ambient air temperature For operation °C - 25…+ 70For storage °C - 40…+ 70
Vibration resistance 5 gn (0…500 Hz) conforming to IEC 60068-2-6
Shock resistance 00 gn conforming to IEC 60068-2-27
Electric shock protection Class II conforming to IEC 640
Degree of protection IP 65 conforming to IEC 60529 IK 08 conforming to EN 5002
Mechanical durability(in millions of operating cycles)
Enclosure Double insulated polypropylene, coloured yellow throughout
Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7…Ø 5 mm
Contact block characteristicsRated operational characteristics a AC-5: A600 or Ue = 600 V, le = .2 A or Ue = 240 V, Ie = 3 A
c DC-3: Q600 or Ue = 600 V, le = 0 . A or Ue = 250 V, Ie = 0 .27 Aconforming to EN/IEC 60947-5- Appendix A
Thermal current (lthe) A 0
Rated insulation voltage (Ui) V 600, degree of pollution 3, conforming to IEC 60947-
Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-
Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5- Appendix K
Contact operation Slow break
Resistance across terminals MW y 25
Operating force N 3 to 5
Terminal referencing By numbers conforming to CENELEC EN 5003
Short-circuit protection 0 A cartridge fuse type gG (gl)
Connection mm2 Screw and captive cable clamp terminals . Clamping capacity: x 2 .5 or 2 x .5 with or without cable end
Rated operational power Conforming to EN/IEC 60947-5- Appendix C . Utilisation categories AC-5 and DC-3 . Operating rate: 3600 operating cycles/hour . Load factor: 0 .5 .
a.c. supply a 50/60 Hz o Inductive circuit
d.c. supply c Power broken in W for million operating cycles
Voltage V 24 48 120o W 65 48 40
1 2 4 6 100,1
0,2
0,4
0,6
1
230 V 127 V
24...48 V
Ithe
Mill
ions
of o
pera
ting
cycl
es
1 2 4 6 100,1
0,2
0,4
0,6
1
230 V 127 V
24...48 V
Ithe
Mill
ions
of o
pera
ting
cycl
es
References:pages 6/5 and 6/6
Dimensions:page 6/7
Application schemes:page 6/7
References:pages 6/5 and 6/6
Dimensions:page 6/7
Application schemes:page 6/7
References:pages 6/5 and 6/6
Dimensions:page 6/7
Application schemes:page 6/7
References:pages 6/5 and 6/6
Dimensions:page 6/7
Application schemes:page 6/7
Pendant control stations 6 Double insulated with intuitive operation, type XAC A “Pistol grip”For control circuits
1
2
3
4
5
6
7
8
9
10
6/5
References 6
For control of single-speed hoist motors Functions Number of
operatorsType of operators
Contact block(s) and scheme Reference WeightPer direction For Emergency stop kg
2 mechanically interlocked
Standard N/O ZB2 BE0
– XAC A201 0 .270
N/C + N/OZB2 BE02 + ZB2 BE0
– XAC A205 0 .300
Booted N/O ZB2 BE0
– XAC A211 0 .290
N/C + N/OZB2 BE02 + ZB2 BE0
– XAC A215 0 .320
2 mechanically interlocked + trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (1)
Standard N/O ZB2 BE0
N/C ZB2 BE02
XAC A2014 0 .30
N/C + N/OZB2 BE02 + ZB2 BE0
N/C ZB2 BE02
XAC A2054 0 .340
Booted N/O ZB2 BE0
N/C ZB2 BE02
XAC A2114 0 .30
N/C + N/OZB2 BE02 + ZB2 BE0
N/C ZB2 BE02
XAC A2154 0 .340
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
1314
1314
XACA201
DF5
655
5
XACA211
DF5
655
6
XACA201
DF5
655
5
XACA211
DF5
655
6
1314
1112
1314
1112
1314
1314
1314
1112
1314
1112
XACA2014
DF5
655
7
XACA2114
DF5
655
8
XACA2014
DF5
655
7
XACA2114
DF5
655
8 1314
1314
1112
1112
1314
1112
1314
1112
1112
1112
1314
1314
1112
1112
1314
1112
1314
1112
1112
1112
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Pendant control stations 6 Double insulated with intuitive operation, type XAC A “Pistol grip”For control circuitsComplete stations “ready for use”
1
2
3
4
5
6
7
8
9
10
6/6
References 6
For control of 2-speed hoist motors Functions Number of
operatorsType of operators
Contact block(s) and scheme Reference WeightPer direction For Emergency stop kg
2 mechanically interlocked
Standard 2 step N/O + N/O staggered ZB2 BE0 + ZB2 BE20
– XAC A207 0 .320
Booted 2 step N/O + N/O staggered ZB2 BE0 + ZB2 BE20
– XAC A217 0 .320
2 mechanically interlocked + trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (1)
Standard 2 step N/O + N/O staggered ZB2 BE0 + ZB2 BE20
N/C ZB2 BE02
XAC A2074 0 .360
Booted 2 step N/O + N/O staggered ZB2 BE0 + ZB2 BE20
N/C ZB2 BE02
XAC A2174 0 .360
Separate components and spare partsDescription For use with Marking/
FunctionScheme Reference Weight
kgBooted pushbutton operators with fixing screws
XAC A2p XAC A25p (single-speed)
– XAC A921 0 .00
– XAC A922 0 .00
XAC A27p (2-speed)
– XAC A923 0 .00
– XAC A924 0 .00
Contact blocks spring return, slow break
XAC A all models
N/O ZB2 BE101 0 .05
N/C ZB2 BE102 0 .05
N/O staggered ZB2 BE201 0 .05
Protective cable sleeve + suspension ring + cable clamp
Cable Ø 7 to Ø 3 mm
– – XAC A913 0 .070
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
1314
2324
1314
2324
XACA207
DF5
6552
0
XACA217
DF5
655
9
XACA207
DF5
6552
0
XACA217
DF5
655
9
1314
2324
1314
2324
XACA2074
DF5
6552
XACA2174
DF5
6552
2
XACA2074
DF5
6552
XACA2174
DF5
6552
2 1314
2324
1314
2324
1112
1112
1314
2324
1314
2324
1112
1112
XACA921
8039
98
XACA921
8039
98
XACA923
8039
90
XACA923
8039
90
ZB2BEppp
5306
67
ZB2BEppp
5306
67
21
21
XACA913
5306
68
XACA913
5306
68
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Characteristics:page 6/4
Dimensions:page 6/7
Application schemes:page 6/7
Pendant control stations 6 Double insulated with intuitive operation, type XAC A “Pistol grip”For control circuitsComplete stations “ready for use”
1
2
3
4
5
6
7
8
9
10
6/7
Dimensions,applicationschemes 6
DimensionsXAC A2pp XAC A2ppp
(1)WithtriggeractionlatchingØ30mmEmergencystopZA2BS834.
Application schemes (typical examples)For control of single-speed reversing motorXAC A2p1p XAC A2p5p
For control of 2-speed reversing motorXAC A2p7p
11.. .13
71
45,5
7.. .99. . .11
13.. .15
39
235
295
52
internal Ø
11.. .13
71
45,5
7.. .99. . .11
13.. .15
39
235
295
52
internal Ø
39
235
295
52101 (1)
45,5
11...13
7...99...11
13...15
internal Ø
39
235
295
52101 (1)
45,5
11...13
7...99...11
13...15
internal Ø
1314
1314
A1
A2
– KM2
– S1
A1
A2
– KM1
– S2
1112
1314
1314
A1
A2
– KM2
– S1
A1
A2
– KM1
– S2
1112
1314
1112
1314
1112 A
1A
2
– KM1
– S1
A1
A2
– KM2
– S2
1112
1314
1112
1314
1112 A
1A
2
– KM1
– S1
A1
A2
– KM2
– S2
1112
2423
24
13 23
1413
14
A1
A2
– KM1
A1
A2
– KM
– S1
A1
A2
– KM2
– S2
1112
2423
24
13 23
1413
14
A1
A2
– KM1
A1
A2
– KM
– S1
A1
A2
– KM2
– S2
1112
Characteristics:page 6/4
References:pages 6/5 and 6/6
Characteristics:page 6/4
References:pages 6/5 and 6/6
Characteristics:page 6/4
References:pages 6/5 and 6/6
Characteristics:page 6/4
References:pages 6/5 and 6/6
Pendant control stations 6 Double insulated with intuitive operation, type XAC A “Pistol grip”For control circuitsComplete stations “ready for use”
1
2
3
4
5
6
7
8
9
10
6/8
EnvironmentConformity to standards EN/IEC 60947-5-
EN/IEC 60204-32, UL 508, CSA C22-2 n° 4EN/IEC 60947-5-5 and EN/ISO 3850: 2006 for versions with trigger action Emergency stop
Protective treatment Standard version “TH”
Ambient air temperature For operation °C - 25…+ 70For storage °C - 40…+ 70
Vibration resistance 5 gn (0…500 Hz) conforming to IEC 60068-2-6
Shock resistance 70 gn conforming to IEC 60068-2-27
Electric shock protection Class II conforming to IEC 640
Degree of protection IP 65 conforming to IEC 60529IK 08 conforming to EN 5002
Mechanical durability(in millions of operating cycles)
3
Enclosure Double insulated polypropylene, coloured yellow throughout
Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7…Ø 8 mm
Contact block characteristicsRated operational characteristics a AC-5: A600 or Ue = 600 V, le = .2 A or Ue = 240 V, Ie = 3 A
c DC-3: Q600 or Ue = 600 V, le = 0 . A or Ue = 250 V, Ie = 0 .27 Aconforming to EN/IEC 947-5- Appendix A
Thermal current (lthe) XAC D2pA010p A 0XAC D2pA12p1 A 6
Rated insulation voltage (Ui) V 600, degree of pollution 3, conforming to IEC 60947-
Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-
Positive operation Mushroom head pushbutton on XAC D22Apppp: N/C contact with positive opening operation conforming to EN/IEC 60947-5- Appendix K
Contact operation Single-speed contact blocks: slow break2-speed contact blocks: snap action
Resistance across terminals MW y 25
Operating force XAC D2pA010p, XAC D2pA12p1
N 6
Terminal referencing By numbers conforming to CENELEC EN 5003
Short-circuit protection 0 A cartridge fuse type gG (gl)
Connection mm2 Captive screw clamp terminals Clamping capacity: x 2 .5 or 2 x .5 with or without cable end
Operational power Conforming to IEC 60947-5- Appendix C . Utilisation categories AC-5 and DC-3 . Operating rate: 3600 operating cycles/hour . Load factor: 0 .5 .
a.c.supply a 50/60 Hz o Inductive circuit
d.c. supply c Power broken in W for million operating cycles
Voltage V 24 48 120o W 65 48 40
1 2 4 6 100,1
0,2
0,4
0,6
1
230 V 127 V
24...48 V
Ithe
Mill
ions
of o
pera
ting
cycl
es
Current in A1 2 4 6 10
0,1
0,2
0,4
0,6
1
230 V 127 V
24...48 V
Ithe
Mill
ions
of o
pera
ting
cycl
es
Current in A
References:page 6/9
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
References:page 6/9
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
References:page 6/9
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
References:page 6/9
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control circuits
Characteristics 6Characteristics 6
1
2
3
4
5
6
7
8
9
10
6/9
For control of single-speed hoist motorsFunctions Number of
operatorsContact block(s) and scheme Reference Weight
kgPer direction For Emergency stop
Reversing, mechanically interlocked
1 2-directional operator
N/O ZB2 BE0
– XAC D21A0101 0 .340
N/C + N/O ZB2 BE02 + ZB2 BE0
– XAC D21A0105 0 .365
1 2-directional operator + trigger action Emer . stop Ø 30 mm ZA2 BS834 operator(2)
N/O ZB2 BE0
N/C ZB2 BE02
XAC D24A0101 0 .395
N/C + N/O ZB2 BE02 + ZB2 BE0
N/C ZB2 BE02
XAC D24A0105 0 .425
For control of 2-speed hoist motorsFunctions Number of
operatorsContact block(s) and scheme Reference Weight
kgPer direction For Emergency stop
Reversing, mechanically interlocked
1 2-directional operator
N/O + N/O staggered XED S23 (1)
– XAC D21A1231 0 .365
N/C + N/O + N/O staggered XED S24 (1)
– XAC D21A1241 0 .405
1 2-directional operator + trigger action latching Emergency stop Ø 30 mm ZA2 BS834 operator (2)
N/O + N/O staggered XED S23 (1)
N/C ZB2 BE02
XAC D24A1231 0 .420
N/C + N/O + N/O staggered XED S24 (1)
N/C ZB2 BE02
XAC D24A1241 0 .420
(1)Referenceofdoublecontactblockforreversingoperation.(2)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,
Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
1314
1314
XACD21A0101
DF5
6550
3
XACD21A0101
DF5
6550
3
1314
1112
1314
1112
XACD24A0105
DF5
6550
XACD24A0105
DF5
6550
1314
1314
1112
1112
1314
1112
1314
1112
1112
1112
2324
1314
4344
3334
S1
S2
2324
1314
4344
3334
S1
S2
XACD21A1231
DF5
6550
4
XACD21A1231
DF5
6550
4
232452
51 1314
434462
61 3334
S1
S2
232452
51 1314
434462
61 3334
S1
S2
XACD24A1241
DF5
6550
2
XACD24A1241
DF5
6550
2
1112
1112
2324
1314
4344
3334
S1
S2
2324
1314
4344
3334
S1
S2
1112
1112
232452
51 1314
434462
61 3334
S1
S2
232452
51 1314
434462
61 3334
S1
S2
Characteristics:page 6/8
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:page 6/8
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:page 6/8
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:page 6/8
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control circuitsComplete stations “ready for use”
References 6References 6
1
2
3
4
5
6
7
8
9
10
6/0
Characteristics 6
EnvironmentConformity to standards EN/IEC 60947-5-
EN/IEC 60204-32, UL 508, CSA C22-2 n° 4EN/IEC 60947-5-5 and EN/ISO 3850: 2006 for versions with trigger action Emergency stopEN/IEC 60947-3
Protective treatment Standard version “TH”
Ambient air temperature For operation °C - 25…+ 70For storage °C - 40…+ 70
Vibration resistance 5 gn (0…500 Hz) conforming to IEC 60068-2-6
Shock resistance 00 gn conforming to IEC 60068-2-27 except XAC D 2-speed: 70 gn
Electric shock protection Class II conforming to IEC 640
Degree of protection IP 65 conforming to IEC 60529IK 08 conforming to EN 5002
Mechanical durability(in millions of operating cycles)
3
Enclosure Double insulated polypropylene, coloured yellow throughout
Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7…Ø 8 mm
Contact block characteristicsThermal current (lthe) XEN Tpppp A 0
XED Spppp A 6
Rated insulation voltage (Ui) V 500, degree of pollution 3 conforming to IEC 60947-400, degree of pollution 3 for Emergency stop contact on stations XAC D22Ppppp
Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-4 for Emergency stop contact on stations XAC D22Ppppp
Contact operation Snap action
Operating force N Single-speed: 28; 2-speed: 3
Terminal referencing By numbers conforming to CENELEC EN 50005
Short-circuit protection 6 A maximum cartridge fuse type aM
Connection mm2 Screw clamp terminals Clamping capacity: x 2 .5 or 2 x .5 with or without cable end
Operational power Utilisation categories AC-3 and AC-4 conforming to IEC 60947-3 Appendix A3 phases, 2 polesXED S2ppp: . kW-400 VXED S3ppp: 2 .2 kW-400 VBrake contact: 00 V d .c . supply, 0 .7 A, L/R = 00 msUtilisation category AC-23B, mushroom head Emergency stop3 phases, 3 poles, isolating block:XEN Tpppp: 3 kW-400 V
Electrical durability(in millions of operating cycles)
Utilisation categories AC-3 and AC-4 conforming to IEC 60947-3 Appendix ADuty cycle comprising 75% AC-3, 25% AC-4Operating rate: 600 per hour, load factor: 0 .43 phases, 2 polesXED S2ppp: . kW-400 V = millionXED S3ppp: 2 .2 kW-400 V = million
References:page 6/
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
References:page 6/
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
References:page 6/
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
References:page 6/
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor power circuits (direct switching)
1
2
3
4
5
6
7
8
9
10
6/
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor power circuits (direct switching)Complete stations “ready for use”
References 6
For control of single-speed hoist motors Functions Number of
operatorsContact blocks Maximum
operational power/400 V
Reference WeightPer direction For Emergency
stop kg
Reversing, mechanically interlocked
1 2-directional operator
2-pole XED S2 (1)
– . kW XAC D21P2111 0 .355
2-pole XED S3 (1)
– 2 .2 kW XAC D21P3111 0 .355
2-pole + N/O (brake) XED S22 (1)
– . kW XAC D21P2121 0 .355
2-pole + N/O (brake) XED S32 (1)
– 2 .2 kW XAC D21P3121 0 .355
1 2-directional operator + trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (2)
2-pole XED S3 (1)
N/C + N/C + N/CXEN T99
2 .2 kW XAC D24P3111 (2) 0 .40
2-pole + N/O (brake) XED S22 (1)
N/C + N/C + N/CXEN T99
. kW XAC D24P2121 (2) 0 .40
2-pole + N/O (brake) XED S32 (1)
N/C + N/C + N/CXEN T99
2 .2 kW XAC D24P3121(2) 0 .40
For control of 2-speed hoist motors Functions Number of
operatorsContact blocks Maximum
operational power/400 V
Reference WeightPer direction For Emergency
stop kg
Reversing, mechanically interlocked
1 2-directional operator
2-pole XED S223 (1)
– . kW XAC D21P2231 0 .355
2-pole XED S323 (1)
– 2 .2 kW XAC D21P3231 0 .355
2-pole + N/O (brake) XED S224 (1)
– . kW XAC D21P2241 0 .355
2-pole + N/O (brake) XED S324 (1)
– 2 .2 kW XAC D21P3241 0 .355
1 2-directional operator + trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834 (2)
2-pole XED S223 (1)
N/C + N/C + N/CXEN T99
. kW XAC D24P2231(2) 0 .420
2-pole XED S323 (1)
N/C + N/C + N/CXEN T99
2 .2 kW XAC D24P3231(2) 0 .420
2-pole + N/O (brake) XED S324 (1)
N/C + N/C + N/CXEN T99
2 .2 kW XAC D24P3241(2) 0 .420
(1)Referenceofdoublecontactblockforreversingoperation.(2)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,
EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
XACD21P2111
DF5
6550
0
XACD21P2111
DF5
6550
0
XACD24P2121
DF5
6550
XACD24P2121
DF5
6550
XACD21P2231
DF5
6550
4
XACD21P2231
DF5
6550
4
XACD24P3241
DF5
6550
2
XACD24P3241
DF5
6550
2
Characteristics:page 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:page 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:page 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:page 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
1
2
3
4
5
6
7
8
9
10
6/2
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control or power circuitsEmpty enclosures, separate components and spare parts
References 6
Empty enclosuresDescription Enclosure cut-outs Reference Weight
kgEmpty enclosurecomprising:- the enclosure, - protective cable sleeve for Ø 7 to 8 mm cable, - internal cable clamp, - cable tie (for tightening sleeve onto cable), - the directional operator, - legends .
For directional operator XAC D021 0 .345
For directional operator + operating head (Ø 22 .5 mm cut-out)
XAC D022 0 .345
Variable composition stations, factory assembledUse the order form on page 6/7 to define the required configuration.
Equipment: contact blocks and operating heads See separate components, pages 6/3 and 6/4
Contact blocks Description Application Function
(1)Scheme (1)
Max. power/400 V
Reference Weightkg
For control circuitsSingle block spring return, slow break
Single-speed N/O – ZB2 BE101 0 .05
N/C – ZB2 BE102 0 .05
Double block spring return, snap action
2-speed N/O + N/O staggered
– XED S1231 0 .05
N/C + N/O + N/O staggered
– XED S1241 0 .05
For power circuitsDouble block spring return, snap action
Single-speed 2-pole (2) . kW XED S2111 0 .0802 .2 kW XED S3111 0 .090
2-pole + N/O (brake)
(2) . kW XED S2121 0 .0902 .2 kW XED S3121 0 .090
2-speed 2-pole (2) . kW XED S2231 0 .02 .2 kW XED S3231 0 .0
2-pole + N/O (brake)
(2) . kW XED S2241 0 .202 .2 kW XED S3241 0 .20
For Emergency stop operating head (Ø 22 .5 mm cut-out) Single block spring return, slow break
N/C – ZB2 BE102 0 .05
N/C + N/C + N/C
– XEN T1991 0 .040
(1)Functionorschemeperdirectionfordoublecontactblocks.(2)Seeapplicationschemes,page6/15.
XACD021
DF5
6550
5
XACD021
DF5
6550
5
XACD022
DF5
6550
6
XACD022
DF5
6550
6
34
34
ZB2BE10p
DF5
6550
5
ZB2BE10p
DF5
6550
5
21
21
2324
1314
4344
3334
S1
S2
2324
1314
4344
3334
S1
S2
XEDS1231
DF5
6550
5
XEDS1231
DF5
6550
5
232452
51 1314
434462
61 3334
S1
S2
232452
51 1314
434462
61 3334
S1
S2
XEDS2121
DF5
6550
9
XEDS2121
DF5
6550
9
1112
1112
1112
2122
3132
1112
2122
3132
XENT1991
DF5
655
0
XENT1991
DF5
655
0
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
1
2
3
4
5
6
7
8
9
10
6/3
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control or power circuitsSeparate components and spare parts
References 6
Contact block support plates For use with Reference Weight
kg2 movement contact blocks ZB2 BE0p (control circuit stations)
XAC D913 0 .00
1 contact block ZB2 BE02 for operating head XAC D911 0 .005
1 contact block XEN T99 for operating head XAC D912 0 .00
Operating heads for Ø 22.5 mm cut-out Description Colour Reference Weight
kg1 trigger action latching Emergency stop Ø 30 mm operator (1)Turn to release
Red ZA2 BS834 0 .040
1 trigger action latching Emergency stop Ø 30 mm operator Key release, n° 455 (2)Key withdrawal in rest (unactuated) position
Red ZA2 BS934 0 .060
Selector switch, standard handle 2 position, stay put
Black ZA2 BD2 0 .08
Key switch (key n° 455) (2)2 position, stay putKey withdrawal in left-hand position
– ZA2 BG2 0 .020
Key switch (key n° 455) (2)2 position, spring return from right to leftKey withdrawal in left-hand position
– ZA2 BG6 0 .020
Key switch (key n° 455) (2)2 position, stay putKey withdrawal in left and right-hand position
– ZA2 BG4 0 .020
Key switch (key n° 455) (2)(3)3 position, stay putKey withdrawal in left and right-hand position
– ZA2 BG5 0 .020
Key switch (key n° 455) (2)(3)3 position, stay putKey withdrawal in centre position
– ZA2 BG3 0 .020
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
(2) Other key numbers available on request, please consult your Regional Sales Office.(3)Onlysuitableforfrontmounting.
XACD913
875
05
XACD911
875
038
7504
XACD912
XACD913
875
05
XACD911
875
038
7504
XACD912
ZA2BS834
874
95
ZA2BS834
874
95
ZA2BS934
DF5
3849
4
ZA2BS934
DF5
3849
4
ZA2BD2
DF5
655
3
ZA2BD2
DF5
655
3
ZA2BG2
DF5
655
4
ZA2BG2
DF5
655
4
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
Dimensions:page 6/4
Application schemes:page 6/5
Presentation:page 6/6
1
2
3
4
5
6
7
8
9
10
6/4
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control or power circuitsComplementary accessories
Complementary accessoriesProtective cable sleeve for cable Ø 7 to 8 mm – XAC D901 0 .030
Diaphragm for directional operator, polychloroprene Black XAC D902 0 .05
Tightening tool for fixing nut – ZA2 BZ905 0 .060
Directional operator with set of legends (single-speed and 2-speed)
– XAC D905 0 .005
Blanking plug for Ø 22 .5 mm cut-out, with seal and fixing nut
Black ZB2 SZ3 0 .00
Printed labels, pendant station characteristicsDescription Pendant station
circuit typeSold inlots of
Unit reference Weightkg
Self-adhesive labels product identification
Control 50 XAC D950 0 .00
Power, . kW 50 XAC D951 0 .00
Power, 2 .2 kW 50 XAC D952 0 .00
DimensionsXAC Dppp
(1)WithtriggeractionlatchingØ30mmEmergencystopZA2BS834.
XACD901
.87
500
XACD901
.87
500
XACD902
.87
50
XACD902
.87
50
5303
06
ZA2BZ905
5303
06
ZA2BZ905
XACD905
.565
259
XACD905
.565
259
ZB2SZ3
875
06
ZB2SZ3
875
06
91
10…1213…1516…18
Ø8
82
300,
5
240
7......9
118 (1)91
10…1213…1516…18
Ø8
82
300,
5
240
7......9
118 (1)
References,dimensions 6
internal Ø
1
2
3
4
5
6
7
8
9
10
6/5
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control or power circuits
Applicationschemes(typicalexamples) 6
Control circuitsXAC D21A0101 XAC D21A0105
XAC D21A1231 XAC D21A1241
Power circuitsFor control of single-speed reversing motor2-phase switchingXAC D21P2111, XAC D21P3111 XAC D21P2121, XAC D21P3121
(1)Brakesupply.
For control of 2-speed reversing motor (motors with separate windings only)2-phase switchingXAC D21P2231, XAC D21P3231 XAC D21P2241, XAC D21P3241
(1)Brakesupply.
– KM1
131423
24A
1A
2
– KM2
– S1
A1
A2
– S2
– KM1
131423
24A
1A
2
– KM2
– S1
A1
A2
– S2
1314
1112
2324
2122
A1
A2
– KM1
– S1
A1
A2
– KM2– S2
1314
1112
2324
2122
A1
A2
– KM1
– S1
A1
A2
– KM2– S2
2443
44
13 23
1433
34 A1
A2
– KM1
A1
A2
– KM
– S1
A1
A2
– KM2
– S2
2443
44
13 23
1433
34 A1
A2
– KM1
A1
A2
– KM
– S1
A1
A2
– KM2
– S2
2443
44
13 23
14
5152
3334
6162 A
1A
2
– KM2
A1
A2
– KM
– S1A
1A
2
– KM1
– S2
2443
44
13 23
14
5152
3334
6162 A
1A
2
– KM2
A1
A2
– KM
– S1A
1A
2
– KM1
– S2
L1 L2 L3
12
34
56
78
– S1
– S2
U V W
L1 L2 L3
12
34
56
78
– S1
– S2
U V W
L1 L2 L3
12
34
56
78
1314
1516
– S1
– S2
U V W
(1) L1 L2 L3
12
34
56
78
1314
1516
– S1
– S2
U V W
(1)
– S1
– S2
910
1112
R1
R2
R3
R4
56
78
12
34
U2
V2
W2
U1
V1
W1
L1 L2 L3
– S1
– S2
910
1112
R1
R2
R3
R4
56
78
12
34
U2
V2
W2
U1
V1
W1
L1 L2 L3
– S1
– S2
910
1112
R1
R2
R3
R4
56
78
12
34
U2
V2
W2
U1
V1
W1
L1 L2 L3
1314
1516
Y
(1)
– S1
– S2
910
1112
R1
R2
R3
R4
56
78
12
34
U2
V2
W2
U1
V1
W1
L1 L2 L3
1314
1516
Y
(1)
Characteristics:pages 6/8 and 6/0
References:pages 6/9 to 6/3
Dimensions:page 6/4
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
References:pages 6/9 to 6/3
Dimensions:page 6/4
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
References:pages 6/9 to 6/3
Dimensions:page 6/4
Presentation:page 6/6
Characteristics:pages 6/8 and 6/0
References:pages 6/9 to 6/3
Dimensions:page 6/4
Presentation:page 6/6
1
2
3
4
5
6
7
8
9
10
6/6
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control or power circuits Variable composition stations, factory assembled
Presentation 6
1
2
3
4
5
6
7
8
9
10
6/7
Pendant control stations 6 Double insulated with intuitive operation, type XAC DFor control or power circuitsVariable composition stations, factory assembled
D 0 2
Orderform(specimensuitableforphotocopying) 6
Customer Schneider Electric IndustriesCompany Order N° Delivery date Sales office - Subsidiary Co. Order N°
Enter the order with XAC D09 referenceUnit reference of empty enclosure, see page 6/2 Number of identical stations Enclosure price (1)
XAC
The reference of the empty enclosure above comprises:- the enclosure, - internal cable clamp, - cable tie (for tightening sleeve onto cable), - the directional operator with set of legends, XAC D905, - protective cable sleeve for Ø 7 to 8 mm cable, XAC D901, - diaphragm for directional operator, XAC D902 .
Operating headsee page 6/3
Contact blockssee page 6/2
Support platesee page 6/3
Reference Unit price Reference Unit price Reference Unit price Total price
Contact blockssee page 6/2
Support plate (for ZB2 BEppp only)see page 6/3
Reference Qty . Unit price Reference Qty . Unit price Total price
Factory assembly:Add an additional cost for assembly XAC 9VA
Total price of assembled pendant station
(1)Obtaintheemptyenclosureprice.
1
2
3
4
5
6
7
8
9
10
6/8
Pendant control stations 6 Double insulated, type XAC AFor control circuits
Characteristics 6
EnvironmentConformity to standards EN/IEC 60947-5-
EN/IEC 60204-32, UL 508, CSA C22-2 n° 4EN/IEC 60947-5-5 and EN/ISO 3850: 2006 for versions with trigger action Emergency stop
Product certifications Special version, with suffix “H7”: UL Listed A600-Q600, CSA A600-Q600, CCC, GOST
Protective treatment Standard version “TH”
Ambient air temperature For operation °C - 25…+ 70For storage °C - 40…+ 70
Vibration resistance 5 gn (0…500 Hz) conforming to IEC 60068-2-6
Shock resistance 00 gn conforming to IEC 60068-2-27
Electric shock protection Class II conforming to IEC 640
Degree of protection IP 65 conforming to IEC 60529IK 08 conforming to EN 5002
Mechanical durability(in millions of operating cycles)
Enclosure Double insulated polypropylene, coloured yellow throughout
Cable entry Rubber sleeve with stepped entry diameter for cable Ø 8…Ø 26 mm
Contact block characteristicsRated operational characteristics ZB2 BEppp, XEN Gpppp,
XAC Spppp a AC-5: A600 or Ue = 600 V, le = .2 A or Ue = 240 V, Ie = 3 Ac DC-3: Q600 or Ue = 600 V, le = 0 . A or Ue = 250 V, Ie = 0 .27 A
XEN Tpppp a AC-5: A300 or Ue = 240 V, le = 3 Ac DC-3: Q300 or Ue = 250 V, le = 0 .27 A conforming to EN/IEC 60947-5- Appendix A
Thermal current (lthe) A 0
Rated insulation voltage (Ui) ZB2 BEppp, XEN Gpppp, XAC Spppp
V 600, degree of pollution 3
XEN Tpppp V 400, degree of pollution 3, conforming to EN/IEC 60947-Rated impulse withstand voltage (U imp) kV 6, conforming to EN/IEC 60947-
Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5- Appendix K
Contact operation N/C or N/O slow breakResistance across terminals MW y 25Operating force N Operators
- with N/O contact: 0- with N/C contact: 8- with additional N/O contact: + 5- with additional N/C contact: + 3
Terminal referencing Conforming to CENELEC EN 5003Short-circuit protection 0 A cartridge fuse type gG (gl)Connection mm2 Screw and captive cable clamp terminals . Clamping capacity: min . x 0 .5 mm2, max .,
with or without cable end: 2 x .5 mm2 or x 2 .5 mm2 . 6 .3 mm clips (on request), please consult your Regional Sales office.
Operational power Conforming to EN/IEC 60947-5- Appendix C . Utilisation categories AC-5 and DC-3 . Operating rate: 3600 operating cycles/hour . Load factor: 0 .5 .
a.c.supply a 50/60 Hz o Inductive circuit
d.c. supply c Power broken in W for million operating cycles
Voltage V 24 48 120o W 65 48 40
1 2 4 6 100,1
0,2
0,4
0,6
1
230 V 127 V
24...48 V
Ithe
Mill
ions
of o
pera
ting
cycl
es
Current in A1 2 4 6 10
0,1
0,2
0,4
0,6
1
230 V 127 V
24...48 V
Ithe
Mill
ions
of o
pera
ting
cycl
es
Current in A
References:pages 6/9 to 6/22
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
References:pages 6/9 to 6/22
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
References:pages 6/9 to 6/22
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
References:pages 6/9 to 6/22
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/9
Pendant control stations 6 Double insulated, type XAC AFor control circuitsComplete stations “ready for use”
References 6
For control of single-speed motorsFunctions Number of
operatorsContact block(s) and scheme Reference WeightPer direction For Emergency stop kg
2 mechanically interlocked
N/O ZB2 BE0
– XAC A271 0 .475
N/C + N/O ZB2 BE02 + ZB2 BE0
– XAC A281 0 .500
2 mechanically interlocked + trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834(1)
N/O ZB2 BE0
N/C ZB2 BE02
XAC A2714 (1) 0 .575
N/C + N/O ZB2 BE02 + ZB2 BE0
N/C ZB2 BE02
XAC A2814 (1) 0 .600
N/O ZB2 BE0
N/C + N/C + N/C XEN T92
XAC A27141 (1) 0 .65
N/C + N/O ZB2 BE02 + ZB2 BE0
N/C + N/C + N/C XEN T92
XAC A28141 (1) 0 .635
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
1314
1314
XACA271XACA281
DF5
6552
3
XACA271XACA281
DF5
6552
3
1314
1112
1314
1112
1314
1314
1112
1112
XACA2714XACA2814
DF5
6552
4
XACA2714XACA2814
DF5
6552
4
1314
1112
1314
1112
1112
1112
1314
1314
1112
2122
3132
1112
2122
3132
XACA27141XACA28141
DF5
6552
4
XACA27141XACA28141
DF5
6552
4
1314
1112
1314
1112
1112
2122
3132
1112
2122
3132
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/20
Pendant control stations 6 Double insulated, type XAC AFor control circuitsComplete stations “ready for use”
References(continued) 6
For control of single-speed motors (continued)Functions Number of
operatorsContact block(s) and scheme Reference WeightPer direction For Emergency stop kg
4 mechanically interlocked between pairs
N/O ZB2 BE0
– XAC A471 0 .625
N/C + N/O ZB2 BE02 + ZB2 BE0
– XAC A481 0 .675
4 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1)
N/O ZB2 BE0
N/C ZB2 BE02
XAC A4714(1) 0 .800
N/C + N/O ZB2 BE02 + ZB2 BE0
N/C ZB2 BE02
XAC A4814 (1) 0 .85
N/O ZB2 BE0
N/C + N/C + N/C XEN T92
XAC A47141 (1) 0 .835
N/C + N/O ZB2 BE02 + ZB2 BE0
N/C + N/C + N/C XEN T92
XAC A48141 (1) 0 .850
6 mechanically interlocked between pairs
N/O ZB2 BE0
– XAC A671 0 .860
N/C + N/O ZB2 BE02 + ZB2 BE0
– XAC A681 0 .950
6 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1)
N/O ZB2 BE0
N/C ZB2 BE02
XAC A6714 (1) 0 .845
N/C + N/O ZB2 BE02 + ZB2 BE0
N/C ZB2 BE02
XAC A6814 (1) 0 .935
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO3850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
1314
1314
XACA471XACA481
DF5
6552
5
XACA471XACA481
DF5
6552
5
1314
1112
1314
1112
1314
1314
1112
1112
XACA4714XACA4814XACA47141XACA48141
5302
26
XACA4714XACA4814XACA47141XACA48141
5302
26 1314
1112
1314
1112
1112
1112
1314
1314
1112
2122
3132
1112
2122
3132
1314
1112
1314
1112
1112
2122
3132
1112
2122
3132
1314
1314
XACA671XACA681
5302
23
XACA6714XACA6814
5302
24
XACA671XACA681
5302
23
XACA6714XACA6814
5302
24
1314
1112
1314
1112
1314
1314
1112
1112
1314
1112
1314
1112
1112
1112
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/2
Pendant control stations 6 Double insulated, type XAC AFor control circuitsComplete stations “ready for use”
References(continued) 6
For control of single-speed motors (continued)Functions Number of
operatorsContact block(s) and scheme Reference WeightPer direction For Emergency stop kg
6 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844(1)
N/O ZB2 BE0
N/C + N/C + N/C XEN T92
XAC A67141 (1) 0 .880
N/C + N/O ZB2 BE02 + ZB2 BE0
N/C + N/C + N/C XEN T92
XAC A68141 (1) 0 .970
I O
8 mechanically interlocked between pairs
N/O on 7 operators ZB2 BE0 and N/C on the 8th operator ZB2 BE02
– XAC A871 0 .940
N/C + N/O ZB2 BE02 + ZB2 BE0
– XAC A881 .045
For control of 2-speed motors Functions Number of
operatorsContact block(s) and scheme Reference WeightPer direction For Emergency stop kg
2 mechanically interlocked between pairs
N/C + N/O + N/Ostaggered XEN G9
– XAC A291 0 .525
2 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 30 mm operator ZA2 BS834(1)
N/C + N/O + N/Ostaggered XEN G9
N/CZB2 BE02
XAC A2914 (1) 0 .570
N/C + N/O + N/Ostaggered XEN G9
N/C + N/C+ N/C XEN T92
XAC A29141 (1) 0 .605
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
1314
1314
1112
2122
3132
1112
2122
3132
XACA67141XACA68141
DF5
6552
6
XACA67141XACA68141
DF5
6552
6
1314
1112
1314
1112
1112
2122
3132
1112
2122
3132
1314
1112
1314
1112
XACA871XACA881
DF5
6552
7
XACA871XACA881
DF5
6552
7
1314
1112
1314
1112
1314
2122
3334
1314
2122
3334
XACA291
5302
29
XACA291
5302
29
1314
2122
3334
1314
2122
3334
1112
1112XACA2914
XACA29141
5302
30
XACA2914XACA29141
5302
30
1314
2122
3334
1314
2122
3334
1112
2122
3132
1112
2122
3132
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/22
Pendant control stations 6 Double insulated, type XAC AFor control circuitsComplete stations “ready for use”
References(continued) 6
For control of 2-speed motors (continued)Functions Number of
operatorsContact block(s) and scheme Reference WeightPer direction For Emergency stop kg
4 mechanically interlocked between pairs
N/C + N/O+ N/Ostaggered XEN G9
– XAC A491 0 .625
4 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844(1)
N/C + N/O + N/Ostaggered XEN G9
N/CZB2 BE02
XAC A4914 (1) 0 .675
N/C + N/O + N/Ostaggered XEN G9
N/C + N/C + N/C XEN T92
XAC A49141(1) 0 .700
(a)
(b)
4 mechanically interlocked between pairs
N/C + N/O + N/Ostaggered (a) XEN G9
– XAC A492 0 .675
N/O (b)ZB2 BE0
4 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 (1)
N/C + N/O + N/Ostaggered (a) XEN G9
N/CZB2 BE02
XAC A4924 (1) 0 .700
N/O (b)ZB2 BE0
N/C + N/O + N/Ostaggered (a) XEN G9
N/C + N/C+ N/C XEN T92
XAC A49241 (1) 0 .735
N/O (b)ZB2 BE0
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
1314
2122
3334
1314
2122
3334
XACA491
DF5
6552
8
XACA491
DF5
6552
8
1314
2122
3334
1314
2122
3334
1112
1112
XACA4914XACA49141
5302
3
XACA4914XACA49141
5302
3
1314
2122
3334
1314
2122
3334
1112
2122
3132
1112
2122
3132
1314
2122
3334
1314
2122
3334
XACA492
DF5
6552
8
XACA492
DF5
6552
8
1314
1314
1314
2122
3334
1314
2122
3334
1112
1112
XACA4924XACA49241
5377
43
XACA4924XACA49241
5377
43
1314
1314
1314
2122
3334
1314
2122
3334
1112
2122
3132
1112
2122
3132
1314
1314
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/23
Pendant control stations 6 Double insulated, type XAC AFor control circuitsEmpty enclosures
References 6
Empty enclosuresDescription Number of
cut-outsReference Weight
kgEnclosure comprising:- the enclosure, - internal mounting plate, - protective cable sleeve, - internal cable clamp, - suspension ring, - cable tie (for tightening sleeve onto cable) .
2 XAC A02 0 .440
3 XAC A03 (1) 0 .440
4 XAC A04 0 .540
5 XAC A05 (1) 0 .625
6 XAC A06 0 .665
8 XAC A08 0 .770
2 XAC A12 .000
Variable composition stations, factory assembledUse the order form on page 6/33 to define the required configuration.
Equipment: contact blocks, operating heads (control and signalling), complementary accessories
See separate components,pages 6/24 to 6/29
(1) Enclosures with 3 cut-outs XAC A03 and 5 cut-outs XAC A05 cannot be fitted with a mounting adaptor for base mounted units. The first cut-out can only be used for the Emergency stop function.
XACA02
5302
33
XACA02
5302
33
XACA03
5302
34
XACA03
5302
34
XACA12
5302
34
XACA12
5302
34
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/24
Pendant control stations 6 Double insulated, type XAC AFor control circuitsSeparate components and spare parts
References 6
Contact blocks for front mountingDescription Application Function Scheme Reference Weight
kgSingle block, spring return slow break
Single-speed N/O ZB2 BE101 0 .05
N/C ZB2 BE102 0 .05
N/C + N/O + N/O simultaneous (1)
XEN G1491 0 .040
2-speed N/C + N/O + N/O staggered ()
XEN G1191 0 .040
Double block, latching slow break (2)
Single-speedN/O
N/O
XEN G3781 0 .060
N/O
N/C
XEN G3791 0 .060
Isolating switch, slow break, for front mountingFor mounting in enclosures
Application Function Scheme Reference Weightkg
XAC A03 (frontal cut-out)XAC A05, A06, A08 (frontal or base cut-out)
Emergency stop N/C + N/C + N/C with positive opening operation
XEN T1192 0 .050
(1)OnlyforusewithXACA9pppoperators.(2)Notsuitableforusewiththefollowingoperatingheads:ZA2BB,ZA2BD,ZA2BGandZA2BS.
.
34
34
ZB2BE101ZB2BE102
5302
38
ZB2BE101ZB2BE102
5302
38
21
21
13
14
33
34
21
22
13
14
33
34
21
22
13
14
33
34
21
22
13
14
33
34
21
22
XENG1191XENG1491
5302
37
XENG1191XENG1491
5302
37
1314
1314
1314
1314
XENG3781XENG3791
5302
36
XENG3781XENG3791
5302
36
1314
1112
1314
1112
1112
2122
3132
1112
2122
3132
XENT1192
5302
39
XENT1192
5302
39
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/25
Pendant control stations 6 Double insulated, type XAC AFor control circuitsSeparate components and spare parts
References(continued) 6
Contact blocks for base mountingDescription Function Scheme Reference Weight
kgSpring return slow break(1)
N/O XAC S101 0 .030
N/C XAC S102 0 .030
N/O + N/O XAC S103 0 .045
N/C + N/C XAC S104 0 .045
N/C + N/O XAC S105 0 .045
Pilot light bodies for front mountingDescription Supply voltage Scheme Reference Weight
kgDirect supply Bulb not included (2)
y 400 V ZB2 BV006 0 .05
Direct supply, through resistor Incandescent BA 9s base fitting 130 V bulb included
230 V ZB2 BV007 0 .020
(1)Notsuitableforusewith3-positionoperatingheadsZA2BDandZA2BGorformountinginenclosuresXACA039andXACA03.
(2) Bulb type for use with direct supply units: BA 9s base fitting incandescent bulb U y130Vorneonbulb110Vy U y400V.Maximumpower:2.6W,maximumØ:11mm,maximumlength:28mm.See page6/26.
1314
1314
XACS10p
5302
40
XACS10p
5302
40
1112
1112
2324
1314
2324
1314
1112
2122
1112
2122
1112
2324
1112
2324
X1
X2
X1
X2ZB2BV006
5302
4
ZB2BV006
5302
4
X1
X2
X1
X2
ZB2BV007
5302
42
ZB2BV007
5302
42
1
2
3
4
5
6
7
8
9
10
6/26
Pendant control stations 6 Double insulated, type XAC AFor control circuitsSeparate components and spare parts
References(continued) 6
Operating heads for front mountingDescription Colour Sold in
lots ofUnit reference Weight
kgBooted operators White 10 XAC A9411 0 .00
Black 10 XAC A9412 0 .00
Green 10 XAC A9413 0 .00
Red 10 XAC A9414 0 .00
Yellow 10 XAC A9415 0 .00
Blue 10 XAC A9416 0 .00
Brown 10 XAC A9419 0 .00
Operating heads for front or base mountingDescription Colour Type Reference Weight
kgTrigger action latching Emergency stop (1) Turn to release
Red Ø 30 mm ZA2 BS834 0 .040
Ø 40 mm ZA2 BS844 0 .050
Trigger action latching Emergency stop (2) Key release (n° 455) Key withdrawal in rest (unactuated) position
Red Ø 30 mm ZA2 BS934 0 .060
Ø 40 mm ZA2 BS944 0 .065
Selector switches (3), standard handle (Not to be used with XEN Gpppp contact blocks)
Black 2 position, stay put ZA2 BD2 0 .08
3 position, stay put (4) ZA2 BD3 0 .08
Key switches (2)(key n° 455) Key withdrawal in left and right-hand position
– 2 position, stay put ZA2 BG4 0 .042
3 position, stay put (4) ZA2 BG5 0 .042
Key switch (2)(key n° 455) Key withdrawal in left-hand position
– 2 position, stay put ZA2 BG2 0 .042
Key switch (2)(key n° 455) Spring return from right to leftKey withdrawal in left-hand position
– 2-position ZA2 BG6 0 .042
Key switch (4) (2)(key n° 455) Key withdrawal in centre position
– 3 position, stay put ZA2 BG3 0 .042
Wobblesticks (5) Operates in all directions for fast stop
Black – ZA2 BB2 0 .060
Red – ZA2 BB4 0 .060
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
(2) Other key numbers available on request, please consult your Regional Sales Office.(3) Selector switches available with other mechanical functions, please consult your Regional Sales Office.(4)Onlysuitableforfrontmounting.(5)Basemountingrecommended.
XACA94pp
5302
43
XACA94pp
5302
43
ZA2BS834
5302
49
ZA2BS834
5302
49
ZA2BS944
DF5
3849
3
ZA2BS944
DF5
3849
3
ZA2BDp
5302
45
ZA2BDp
5302
45
ZA2BGp
5302
46
ZA2BGp
5302
46
ZA2BBp
DF5
6552
9
ZA2BBp
DF5
6552
9
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/27
Pendant control stations 6 Double insulated, type XAC AFor control circuitsSeparate components and spare parts
References(continued) 6
Pilot light headsDescription Colour Reference Weight
kgFor use with incandescent bulbs
Lens cap with bezel and fixing nut
White ZA2 BV01 0 .05
Green ZA2 BV03 0 .05
Red ZA2 BV04 0 .05
Yellow ZA2 BV05 0 .05
Blue ZA2 BV06 0 .05
Clear ZA2 BV07 0 .05
For use with neon bulbsLens cap with bezel and fixing nut
Green ZA2 BV033 0 .05
Red ZA2 BV043 0 .05
Yellow ZA2 BV053 0 .05
Clear ZA2 BV073 0 .05
Bulbs Description Voltage Sold in
lots ofUnit reference Weight
kgIncandescent BA 9s base fittingMaximum power: 2 .6 W Maximum Ø: mm Maximum length: 28 mm
6 V 10 DL1 CB006 0 .002
2 V 10 DL1 CE012 0 .002
24 V 10 DL1 CE024 0 .002
48 V 10 DL1 CE048 0 .002
30 V 10 DL1 CE130 0 .002
NeonBA 9s base fitting Maximum power: 2 .6 W Maximum Ø: mm Maximum length: 28 mm
0 V 10 DL1 CF110 0 .002
230 V 10 DL1 CF220 0 .002
400 V 10 DL1 CF380 0 .002
Complementary accessories, toolsDescription Reference Weight
kgProtective cable sleeve For cable Ø 8 to 22 mm XAC A950 0 .070
For cable Ø 8 to 26 mm XAC A960 0 .090
Mechanical interlock for 2 operators
With fixing screws XAC A009 0 .003
Blanking plug With seal and fixing nut ZB2 SZ3 0 .005
Tightening tool for fixing nut
– ZA2 BZ905 0 .060
Adaptor for self-supporting cabletype BBAP
Mounted with protective sleeve for cable Ø 8 to 26 mm
XAC B961 0 .025
Lower support ring – XAC A971 0 .00
Protective guards for base mounted units
For selector switch (standard handle)or Emergency stop head pushbutton
XAC A982 0 .025
For key switch or key release latching Emergency stop head pushbutton
XAC A983 0 .045
Bulb extractor For BA 9s base fitting bulbs XBF X13 0 .025
ZA2BV0p
5302
50
ZA2BV0p
5302
50
DL1Cpppp
5302
0
DL1CFppp
5302
02
DL1Cpppp
5302
0
DL1CFppp
5302
02
XACA960
5302
03
XACA009
ZB2SZ3
DF5
6553
D
F565
530
XACA960
5302
03
XACA009
ZB2SZ3
DF5
6553
D
F565
530
5303
06
ZA2BZ905
5303
06
ZA2BZ905
XACB961
5302
05
XACA971
5302
06
XACB961
5302
05
XACA971
5302
06
XACA982
5302
07
XACA982
5302
07
XACA983
5302
08
XACA983
5302
08
XBFX13
5302
00
XBFX13
5302
00
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/28
Pendant control stations 6 Double insulated, type XAC AFor control circuitsLegends 30 x 40 mm with symbols conforming to NF E 52-24
References 6
Function Symbol
Reference Weightkg
Function Symbol
Reference Weightkg
Raise, slow ZB2 BY4901 0 .00 Lower, slow ZB2 BY2904 0 .00
Raise, fast ZB2 BY4902 0 .00 Lower, fast ZB2 BY2905 0 .00
Raise, slow-fast ZB2 BY4903 0 .00 Lower, slow-fast ZB2 BY2906 0 .00
Right, slow ZB2 BY4907 0 .00 Left, slow ZB2 BY2910 0 .00
Right, fast ZB2 BY4908 0 .00 Left, fast ZB2 BY2911 0 .00
Right, slow-fast ZB2 BY4909 0 .00 Left, slow-fast ZB2 BY2912 0 .00
Forward, slow ZB2 BY4913 0 .00 Reverse, slow ZB2 BY2916 0 .00
Forward, fast ZB2 BY4914 0 .00 Reverse, fast ZB2 BY2917 0 .00
Forward, slow-fast ZB2 BY4915 0 .00 Reverse, slow-fast ZB2 BY2918 0 .00
Slew right, slow ZB2 BY4919 0 .00 Slew left, slow ZB2 BY2922 0 .00
Slew right, fast ZB2 BY4920 0 .00 Slew left, fast ZB2 BY2923 0 .00
Slew right, slow-fast ZB2 BY4921 0 .00 Slew left, slow-fast ZB2 BY2924 0 .00
Slow ZB2 BY4933 0 .00 Fast ZB2 BY4934 0 .00
Klaxon ZB2 BY4932 0 .00 Start-Klaxon ZB2 BY4935 0 .00
Start ZB2 BY4930 0 .00 Stop ZB2 BY2931 0 .00
0
White background, black symbol
5302
09
Black background, white symbol
Red background, white symbol
0
White background, black symbol
5302
09
Black background, white symbol
Red background, white symbol
00
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/29
Pendant control stations 6 Double insulated, type XAC AFor control circuitsLegends 30 x 40 mm
References 6
Text Reference Weightkg
Text Reference Weightkg
Start functions: white characters on black background Stop functions: white characters on red background
bb
BlankBlack or red background
ZB2 BY2101 0 .00 White or yellow background
ZB2 BY4101 0 .00
With English text With French textFor pushbuttons For pushbuttons
Start ZB2 BY2303 0 .00 Marche ZB2 BY2103 0 .00
Stop ZB2 BY2304 0 .00 Arrêt ZB2 BY2104 0 .00
Forward ZB2 BY2305 0 .00 Avant ZB2 BY2105 0 .00
Reverse ZB2 BY2306 0 .00 Arrière ZB2 BY2106 0 .00
Up ZB2 BY2307 0 .00 Montée ZB2 BY2107 0 .00
Down ZB2 BY2308 0 .00 Descente ZB2 BY2108 0 .00
Right ZB2 BY2309 0 .00 Droite ZB2 BY2109 0 .00
Left ZB2 BY2310 0 .00 Gauche ZB2 BY2110 0 .00
On ZB2 BY2311 0 .00 En service ZB2 BY2111 0 .00
Off ZB2 BY2312 0 .00 Hors service ZB2 BY2112 0 .00
Power on ZB2 BY2326 0 .00 Sous tension ZB2 BY2126 0 .00
Slow ZB2 BY2327 0 .00 Lent ZB2 BY2127 0 .00
Fast ZB2 BY2328 0 .00 Vite ZB2 BY2128 0 .00
Klaxon ZB2 BY2125 0 .00 Klaxon ZB2 BY2125 0 .00
For selector switches For selector switches– – 0 .00 Arrêt-Marche ZB2 BY2166 –
Off-On ZB2 BY2367 0 .00 Hors-en ZB2 BY2167 0 .00
With special texts Specify text when ordering, 2 lines maximum, characters per line .
bb
White characters on black background
ZB2 BY2002 0 .00 Black characters on white background
ZB2 BY4001 0 .00
White characters on red background
ZB2 BY2004 0 .00 Black characters on yellow background
ZB2 BY4005 0 .00
Other versions Legends with texts in other languages .Please consult your Regional Sales Office.
5302
ZB2BY2101
RedWhite
Black5302
ZB2BY2101
RedWhite
Black
5302
2
ZB2BY4101
YellowBlack
White5302
2
ZB2BY4101
YellowBlack
White
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
Dimensions:page 6/30
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/30
Pendant control stations 6 Double insulated, type XAC AFor control circuits
Dimensions 6
DimensionsXAC A pendant stations for control circuits
internal Ø
Number of operators 2 3 4 5 6 8 12b 34 34 440 440 500 560 680b 90 90 250 250 30 370 490c 80 80 80 80 80 80 92(1)For2and3-wayXACAstations.(2)For4to8-wayXACAstations.(3)WithtriggeractionEmergencystopheadoperator.
Protective guardsXAC A982 XAC A983
80
33
80
33
80
57
80
57
Characteristics:page 6/8
References:pages 6/9 to 6/29
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
References:pages 6/9 to 6/29
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
References:pages 6/9 to 6/29
Application schemes:page 6/3
Presentation:page 6/32
Characteristics:page 6/8
References:pages 6/9 to 6/29
Application schemes:page 6/3
Presentation:page 6/32
1
2
3
4
5
6
7
8
9
10
6/3
Pendant control stations 6 Double insulated, type XAC AFor control circuits
Applicationschemes 6
Application schemes (typical examples)For control of single-speed reversing motor For control of 2-speed reversing motorContact blocks ZB2 BE101 + ZB2 BE102 2 contact blocks XEN G1191
KM: high speed contactor
1314
1112
1314
1112
A1
A2
– KM2
– S1
A1
A2
– KM1
– S2
1314
1112
1314
1112
A1
A2
– KM2
– S1
A1
A2
– KM1
– S2
3433
34
13 33
14
2122
1314
2122
A1
A2
– KM2
A1
A2
– KM
– S1
A1
A2
– KM1
– S2 – S1
– S2
3433
34
13 33
14
2122
1314
2122
A1
A2
– KM2
A1
A2
– KM
– S1
A1
A2
– KM1
– S2 – S1
– S2
Characteristics:page 6/8
References:pages 6/9 to 6/29
Dimensions:page 6/30
Characteristics:page 6/8
References:pages 6/9 to 6/29
Dimensions:page 6/30
Characteristics:page 6/8
References:pages 6/9 to 6/29
Dimensions:page 6/30
Characteristics:page 6/8
References:pages 6/9 to 6/29
Dimensions:page 6/30
1
2
3
4
5
6
7
8
9
10
6/32
Pendant control stations 6 Double insulated, type XAC AFor control circuitsVariable composition stations, factory assembled
Presentation 6
1
2
3
4
5
6
7
8
9
10
6/33
Pendant control stations 6 Double insulated, type XAC AFor control circuitsVariable composition stations, factory assembled
A
Orderform(specimensuitableforphotocopying) 6
Customer Schneider Electric IndustriesCompany Order N° Delivery date Sales office - Subsidiary Co. Order N°
Enter the order with XAC A09 referenceUnit reference of empty enclosure, see page 6/23 Number of identical stations Enclosure price (1)
XAC
Legendssee pages 6/28 and 6/29
Contact blocks or pilot light bodiessee pages 6/24 and 6/25
Operating heads or pilot light heads or blanking plug see pages 6/26 and 6/27
Reference Unit price Reference Unit price Reference Unit price Total price1
2
3
4
5
6
7
8
9
10
11
12
Unit mounted in base of enclosure (if required) (Except when using XAC A03 and XAC A05)13
Complementary accessories, see page 6/27 (cross the appropriate box or boxes)Description Reference Unit price
14 Adaptor for self-supporting cable type BBAP for use with cable entry sleeve Ø 8 to 26 mm
XAC B961
15 Lower support ring XAC A971
16 Protective guard for selector switch (std . handle) or Emergency stop head pushbutton, mounted in base
XAC A982
17 Protective guard for key switch or key release Emergency stop head pushbutton, mounted in base
XAC A983
Mechanical interlocking (2)Reference Quantity Unit price
XAC A009Factory assembly: Number of heads or blanking
plugs to be fittedAdditional cost XAC 9VA for fitting of head or blanking plug
X
Total price of assembled pendant station
(1)Obtaintheemptyenclosureprice.(2)Connectwithalinethe2wayswhichrequiremechanicalinterlocking.Examples: combinations possible Combinations not possible
17
16
15
13
14
1
2
3
4
5
6
7
8
9
10
12
11
17
16
15
13
14
1
2
3
4
5
6
7
8
9
10
12
11
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
2
3
4
5
1
2
3
4
5
6
7
8
9
10
6/34
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control circuits
Characteristics 6
EnvironmentConformity to standards EN/IEC 60947-5-, CSA C22-2 n° 4
Product certifications XAC B Standard version: CSA 300 V type 4XAC M Standard version: CSA 300 V type 4
Protective treatment XAC B Standard version: “TH”XAC M Standard version: “TC”, (“TH” on request)
Ambient air temperature For storage °C - 40…+ 70For operation °C - 25…+ 70
Vibration resistance 5 gn (0…500 Hz) conforming to IEC 60068-2-6
Shock resistance 00 gn conforming to IEC 60068-2-27
Electric shock protection XAC B Class IIXAC M Class I conforming to IEC 640
Degree of protection IP 65 conforming to IEC 60529; IK 08 conforming to EN 5002Mechanical durability(in millions of operating cycles)
Enclosure XAC B Double insulated glass-reinforced polyester (colour: yellow)XAC M Aluminium enclosure . Painted yellow
Cable entry Rubber sleeve with stepped entry diameter for cable Ø 7…3 mm, Ø 0…22 mm or Ø 22…35 mm
Contact block characteristicsRated operational characteristics a AC-5: A300 or Ue = 240 V, le = 3 A
c DC-3: Q300 or Ue = 250 V, le = 0 .27 A conforming to EN/IEC 60947-5- Appendix A
Thermal current (lthe) A 0Rated insulation voltage (Ui) XEN Cpppp, XEN D3ppp,
XEN D4ppp, XES B2011, XAC S4, XES D1181, XES D1281
V 500, degree of pollution 3, conforming to IEC 60947-
XEN Bpppp, XEN D1ppp, XEN D2ppp
400, degree of pollution 3, conforming to IEC 60947-
Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-
Positive operation Mushroom head pushbutton: N/C contact with positive opening operation conforming to EN/IEC 60947-5- Appendix K
Contact operation Slow break or snap action
Resistance across terminals MW y 25
Operating force With booted operator N XAC S4ppp: 0 (N/O), 8 (N/C); XEN Cpppp: 6 (N/O), 4 (N/C);XEN Bpppp, XEN D1ppp, XEN D2ppp: Single-speed: 9; 2-speed: 20 (st speed), 30 (2nd speed); XEN D3ppp, XEN D4ppp: 25; XES B2011: 7; XES D1181, XES D128: 5 (st speed), 25 (2nd speed)
With spring return mushroom head operator
N 0
With latching mushroom head operator
N 40
Terminal referencing By numbers conforming to CENELEC EN 5003
Short-circuit protection 0 A cartridge fuse type gG (gl)
Connection mm2 Screw and captive cable clamp terminals . Clamping capacity: x 2 .5 or 2 x .5 with or without cable end
Operational powerconforming to EN/IEC 60947-5- Appendix CUtilisation categories AC-5 and DC-3For million operating cyclesOperating rate: 3600 operating cycles/hourLoad factor: 0 .5o Inductive circuit
Contact blocks XEN Cpppp, XEN D3ppp, XEN D4ppp, XAC S4ppp
a.c. supply a 50/60 Hz d.c. supply cVoltage V 24 48 127 230 Voltage V 24 48 120
o VA 40 385 525 455 o W 60 45 42
Contact blocks XEN Bpppp, XEN D1ppp, XEN D2ppp
a.c. supply a 50/60 Hz d.c. supply cVoltage V 24 48 127 230 Voltage V 24 48 120
o VA 40 20 640 680 o W 48 3 35
Contact blocks XES B2011, XES D1181, XES D1281a.c. supply a 50/60 Hz d.c. supply cVoltage V 24 48 127 230 Voltage V 24 48 120
o VA 50 00 450 750 o W 40 40 95
References:page 6/35
Dimensions:page 6/55
Application schemes:page 6/56
References:page 6/35
Dimensions:page 6/55
Application schemes:page 6/56
References:page 6/35
Dimensions:page 6/55
Application schemes:page 6/56
References:page 6/35
Dimensions:page 6/55
Application schemes:page 6/56
1
2
3
4
5
6
7
8
9
10
6/35
Pendant control stations 6 Double insulated, type XAC BFor control circuitsComplete stations “ready for use” (with snap action contact blocks)
References 6
For control of single-speed motorsFunctions Number of
operatorsContact blocks and scheme Reference Weight
kgPer direction2without mechanical interlocking
C/O snap action XES B20
XAC B281 0 .850
4without mechanical interlocking
C/O snap action XES B20
XAC B481 .00
6without mechanical interlocking
C/O snap action XES B20
XAC B681 .300
I
O
8without mechanical interlocking
C/O snap action XES B20
XAC B881 .550
342
1 342
1
XACB281
DF5
6556
4
XACB281
DF5
6556
4
342
1 342
1XACB481
DF5
6556
5
XACB481
DF5
6556
5
342
1 342
1
XACB681
DF5
6556
6
XACB681
DF5
6556
6
342
1 342
1
XACB881
DF5
6556
7
XACB881
DF5
6556
7
Characteristics:page 6/34
Dimensions:page 6/55
Application schemes:page 6/56
Characteristics:page 6/34
Dimensions:page 6/55
Application schemes:page 6/56
Characteristics:page 6/34
Dimensions:page 6/55
Application schemes:page 6/56
Characteristics:page 6/34
Dimensions:page 6/55
Application schemes:page 6/56
1
2
3
4
5
6
7
8
9
10
6/36
Pendant control stations 6 Double insulated, type XAC BFor power circuits (direct switching)
Characteristics 6
EnvironmentConformity to standards EN/IEC 60947-5-
EN/IEC 60204-32, UL 508, CSA C22-2 n° 4EN/IEC 60947-5-5 and EN/ISO 3850: 2006 for versions with trigger action Emergency stop EN/IEC 60947-3
Product certifications Standard version CSA type 4
Protective treatment Standard version “TH”
Ambient air temperature For storage °C - 40…+ 70For operation °C - 25…+ 70
Vibration resistance 5 gn (0…500 Hz) conforming to IEC 60068-2-6
Shock resistance 00 gn conforming to IEC 60068-2-27
Electric shock protection Class II conforming to IEC 640
Degree of protection IP 65 conforming to IEC 60529
Mechanical durability(in millions of operating cycles)
except for XAC B9p and XAC CB92p: 0 .4
Enclosure Double insulated glass-reinforced polyester (colour: yellow)
Cable entry Rubber sleeve with stepped entry diameter for cable Ø 0…Ø 22 mm
Contact block characteristicsThermal current (lthe) XES D1191, XES D1291 A 2
XES D2201, XES D2241, XES D2251
A 20
Rated insulation voltage (Ui) XES Dpppp V 500, degree of pollution 3, conforming to IEC 60947-XAC Sp99 V 400, degree of pollution 3, conforming to IEC 60947-XES D1ppp V 600, conforming to CSAXES D2ppp V 300, conforming to CSA
Rated impulse withstand voltage (U imp) kV 6, conforming to IEC 60947-
Contact operation Snap action
Operating force XES D1ppp N 7XES D2ppp N 32
Terminal referencing By numbers conforming to CENELEC EN 50005
Short-circuit protection XES D1ppp 0 A maximum cartridge fuse type aMXES D2ppp 2 A maximum cartridge fuse type aM
Connection mm2 Captive screw clamp terminalsClamping capacity: x 2 .5 or 2 x .5 with or without cable end
Operational power 3 phases, 2 poles Utilisation categories AC-3 and AC-4 conforming to EN/IEC 60947-3 Appendix AXES D1ppp 2 .2 kW-240 V
2 .2 kW-400 V3 phases, 3 polesXES D2ppp 3 kW-240 V
3 kW-400 V3 phases, 3 poles, isolating block
Utilisation category AC-23B
XAC Sp99 3 kW-400 V3 phases, 2 poles CSA certificationXES D1ppp 2 hp-240 V
5 hp-400 V3 hp-600 V
3 phases, 3 polesXES D2ppp 3 hp-240 V
Mechanical durability(in millions of operating cycles)Utilisation categories AC-3 and AC-4 conforming to EN/IEC 60947-3 Appendix ADuty cycle comprising 75% AC-3, 25% AC-4Operating rate: 600 operating cycles per hourLoad factor: 0 .4
3 phases, 2 polesXES D1ppp .5 kW-240 V = 0 .5
2 .2 kW-240 V = 0 .3 .5 kW-400 V = 0 .82 .2 kW-400 V = 0 .3
3 phases, 3 polesXES D2ppp 3 kW-240 V = 0 .7
3 kW-400 V =
References:pages 6/37 and 6/38
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
References:pages 6/37 and 6/38
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
References:pages 6/37 and 6/38
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
References:pages 6/37 and 6/38
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
1
2
3
4
5
6
7
8
9
10
6/37
Pendant control stations 6 Double insulated, type XAC BFor power circuits (direct switching)Complete stations “ready for use”
References 6
For control of single-speed motorsFunctions Number of
operatorsContact blocks Maximum
operational power/400 V
Reference WeightPer direction For Emergency
stop kg2 mechanically interlocked
2-pole XES D9(1)
– 2 .2 kW XAC B219 0 .355
3-pole XES D220(1)
– 3 kW XAC B220 0 .355
2 mechanically interlocked + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844
2-pole XES D9(1)
N/C + N/C + N/CXAC S499
2 .2 kW XAC B3195 r 0 .940
3-pole XES D220(1)
N/C + N/C + N/CXAC S499
3 kW XAC B3205 r .000
4 mechanically interlocked between pairs
2-pole XES D9(1)
– 2 .2 kW XAC B491 .200
3-pole XES D220(1)
– 3 kW XAC B493 .330
4 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844
2-pole XES D9(1)
N/C + N/C + N/CXAC S499
2 .2 kW XAC B4916 r .260
3-pole XES D220(1)
N/C + N/C + N/CXAC S499
3 kW XAC B4936 r .390
4 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 mounted in base
2-pole XES D9(1)
N/C + N/C + N/CXAC S399
2 .2 kW XAC B4915 r .350
3-pole XES D220(1)
N/C + N/C + N/CXAC S399
3 kW XAC B4935 r .480
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
XACB219XACB220
DF5
6556
8
XACB219XACB220
DF5
6556
8
XACB3195XACB3205
DF5
6556
9
XACB3195XACB3205
DF5
6556
9
XACB491XACB493
DF5
6557
0
XACB491XACB493
DF5
6557
0
XACB4916XACB4936
DF5
6557
XACB4916XACB4936
DF5
6557
XACB4915XACB4935
DF5
6557
2
XACB4915XACB4935
DF5
6557
2
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
r Available 3rd quarter of 2008
1
2
3
4
5
6
7
8
9
10
6/38
Pendant control stations 6 Double insulated, type XAC BFor power circuits (direct switching)Complete stations “ready for use”
References(continued) 6
For control of single-speed motors (continued)Functions Number of
operatorsContact blocks Maximum
operational power/400 V
Reference WeightPer direction For Emergency
stop kg6 mechanically interlocked between pairs
2-pole XES D9(1)
– 2 .2 kW XAC B691 .350
3-pole XES D220(1)
– 3 kW XAC B693 .550
6 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844
2-pole XES D9(1)
N/C + N/C + N/CXAC S499
2 .2 kW XAC B6916 r .40
3-pole XES D220(1)
N/C + N/C + N/CXAC S499
3 kW XAC B6936 r .60
6 mechanically interlocked between pairs + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844 mounted in base
2-pole XES D9(1)
N/C + N/C + N/CXAC S399
2 .2 kW XAC B6915 r .500
3-pole XES D220(1)
N/C + N/C + N/CXAC S399
3 kW XAC B6935 r .700
For control of 2-speed motorsFunctions Number of
operatorsContact blocks Maximum
operational power/400 V
Reference WeightPer direction For Emergency
stop kg2mechanically interlocked
2-pole XES D29(1)
– 2 .2 kW XAC B229 0 .405
2 mechanically interlocked + trigger action latching Emergency stop Ø 40 mm operator ZA2 BS844
2-pole XES D29(1)
N/C + N/C + N/CXAC S499
2 .2 kW XAC B3295 r 0 .990
(1)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
XACB691XACB693
DF5
6557
3
XACB691XACB693
DF5
6557
3
XACB6916XACB6936
DF5
6557
4
XACB6916XACB6936
DF5
6557
4
XACB6915XACB6935
DF5
6557
5
XACB6915XACB6935
DF5
6557
5
XACB229
DF5
6557
6
XACB229
DF5
6557
6
XACB3295
DF5
6557
7
XACB3295
DF5
6557
7
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Characteristics:page 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
r Available 3rd quarter of 2008
1
2
3
4
5
6
7
8
9
10
6/39
Pendant control stations 6 Double insulated, type XAC BFor control or power circuitsEmpty enclosures
References 6
Empty enclosures for control circuits or power circuits (1)Description Protective
cable sleeveNumber of cut-outs
Cut-out in base of enclosure
Reference Weightkg
Empty enclosures (1) Double insulated for “Small hoist” applications Operator cut-out centres: 40 mm
For cable Ø 7…3 mm
2 Without XAC B020 0 .760
3 Without XAC B030 0 .760
Empty enclosures (1) Double insulated for “General purpose” applications Operator cut-out centres: 40 mm
For cable Ø 0…22 mm
2 Without XAC B02 0 .760
With XAC B021 0 .760
4 Without XAC B04 .000
With XAC B041 .000
6 Without XAC B06 .60
With XAC B061 .60
8 Without XAC B08 .330
With XAC B081 .330
2 in 2 rows of 6 Without XAC B12 .460
With XAC B121 .460
(1)Enclosurecomprising:-theenclosure,-protectivecablesleeve,-cabletie(fortighteningsleeveontocable),-internalcableclamp,-suspensionring,-bezeltighteningkey.
XACB020
DF5
6557
8
XACB020
DF5
6557
8
XACB030
DF5
6557
9
XACB030
DF5
6557
9
XACB02p
DF5
6558
0
XACB02p
DF5
6558
0
XACB04p
DF5
6558
XACB04p
DF5
6558
XACB06p
DF5
6558
2
XACB06p
DF5
6558
2
XACB08p
DF5
6558
3
XACB08p
DF5
6558
3
XACB12p
DF5
6558
4
XACB12p
DF5
6558
4
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/40
Pendant control stations 6 Double insulated, type XAC BFor control or power circuitsEmpty enclosures
References(continued) 6
Empty enclosures for control circuits or power circuits (1)(continued)Description Protective
cable sleeveNumber of cut-outs
Cut-out in base of enclosure
Reference Weightkg
Empty enclosures (1) Double insulated for “General purpose” applications Operator cut-out centres: 40 mm
For cable Ø 22…35 mm
2 Without XAC B025 0 .960
With XAC B0215 0 .960
4 Without XAC B045 .200
With XAC B0415 .200
6 Without XAC B065 .360
With XAC B0615 .360
8 Without XAC B085 .530
With XAC B0815 .530
2 in 2 rows of 6 Without XAC B125 .660
With XAC B1215 .660
(1)Enclosurecomprising:-theenclosure,-protectivecablesleeve,-cabletie(fortighteningsleeveontocable),-internalcableclamp,-suspensionring,-bezeltighteningkey.
XACB02pp
DF5
6558
0
XACB02pp
DF5
6558
0
XACB04pp
DF5
6558
XACB04pp
DF5
6558
XACB06pp
DF5
6558
2
XACB06pp
DF5
6558
2
XACB08pp
DF5
6558
3
XACB08pp
DF5
6558
3
XACB12pp
DF5
6558
4
XACB12pp
DF5
6558
4
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/4
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control circuitsEmpty enclosures (XAC M: products for maintenance purposes only)
References 6
Empty enclosures for control circuits (1)Description Protective
cable sleeveNumber of cut-outs
Cut-out in base of enclosure
Reference Weightkg
Empty enclosures (1) Double insulated for “General purpose” applications Operator cut-out centres: 30 mm
For cable Ø 0…22 mm
2 in row Without XAC B120 .330
With XAC B1201 .330
For cable Ø 22…35 mm
2 in row Without XAC B1205 .530
With XAC B12015 .530
Empty enclosures (1) Metal for “General purpose” applications Operator cut-out centres: 40 mm
For cable Ø 0…22 mm
4 Without XAC M04 .540
With XAC M041 .540
8 Without XAC M08 2 .20
With XAC M081 2 .20
For cable Ø 22…35 mm
4 Without XAC M045 .740
With XAC M0415 .740
8 Without XAC M085 2 .40
With XAC M0815 2 .40
Variable composition stations, factory assembledUse the order form on page 6/59 to define the required configuration
Equipment: contact blocks, operating heads (control and signalling), complementary accessories
See separate components, pages 6/42 to 6/54
(1)Enclosurecomprising:-theenclosure,-protectivecablesleeveforcableØ10…22mmorØ22…35mm,-cabletie(fortighteningsleeveontocable),-internalcableclamp,-suspensionring,-bezeltighteningkey.
XACB120
DF5
6558
5
XACB120
DF5
6558
5
XACM04p
DF5
6558
6
XACM04p
DF5
6558
6
XACM08p
DF5
6558
7
XACM08p
DF5
6558
7
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/42
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control circuitsSeparate components and spare parts
References 6
Contact blocks for front mounting, slow breakDescription Application Function Scheme Operator
centresReference Weight
mm kgSpring return
Single block spring return operator
Single-speed N/O 30 or 40 XEN C1111 0 .020
N/C 30 or 40 XEN C1121 0 .020
N/O + N/O 30 or 40 XEN C1131 0 .020
N/C + N/C 30 or 40 XEN C1141 0 .020
N/C + N/O 30 or 40 XEN C1151 0 .020
C/O + N/O 30 or 40 XEN B1491 0 .050
2-speed 2 step N/O + N/O staggered
30 or 40 XEN B1181 0 .050
2 step C/O + N/O staggered
30 or 40 XEN B1191 0 .050
Double block 2 spring return operators mechanically interlocked
Single-speed N/O + N/Osimultaneous
30 XEN D1611 0 .0
40 (1) XEN D2611 0 .0
2-speed 2 step N/O + N/O staggered
30 XEN D1621 0 .0
40 (1) XEN D2621 0 .0
(1)ThesecontactblockscannotbemountedinenclosuresXACB120p(12operatorsin1row).
1314
1314
XENC1111
DF5
6558
8
XENC1111
DF5
6558
8
1112
1112
1314
2324
1314
2324
1112
2122
1112
2122
2324
1112
2324
1112
131432
31 2324
131432
31 2324
434434
33 434434
33
XENB1181
DF5
6558
9
XENB1181
DF5
6558
9
131432
31 2324
131432
31 2324
1314
2324
3334
4344
1314
2324
3334
4344
XEND2611
DF5
6559
0
XEND2611
DF5
6559
0
1314
2324
3334
4344
1314
2324
3334
4344
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/43
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control circuitsSeparate components and spare parts
References(continued) 6
Contact blocks for front mounting, slow break (continued)Description Application Function Scheme Operator
centresReference Weight
mm kgSpring return (continued)
Double block 2 spring return operators mechanically interlocked
Single-speed C/O + N/O 30 XEN D1631 0 .0
40 (1) XEN D2631 0 .0
2-speed 2 step C/O + N/O staggered
30 XEN D1641 0 .0
40 (1) XEN D2641 0 .0
LatchingDouble block latching operator released by spring return operator
Single-speed N/C + N/O 30 XEN D3801 0 .70
40 (1) XEN D4801 0 .70
Double block 2 latching operators
Single-speed N/C + N/O 30 XEN D3811 0 .70
40 (1) XEN D4811 0 .70
Contact blocks for front mounting, snap actionDescription Application Function Scheme Operator
centresReference Weight
mm kgSpring return
Single block spring return operator(2)
Single-speed C/O 40 (1) XES B2011 0 .030
Double block 2 spring return operators mechanically interlocked
Single-speed C/O 40 (1) XES D1181 0 .40
2-speed C/O + N/O staggered
40 (1) XES D1281 0 .90
(1)ThesecontactblockscannotbemountedinenclosuresXACB120p (12operatorsin1row).(2)OnlyformountingwithoperatorsXACB91pp.
131432
31 2324
434462
61 5354
131432
31 2324
434462
61 5354
131432
31 2324
434462
61 5354
131432
31 2324
434462
61 5354
XEND2641
DF5
6559
3
XEND2641
DF5
6559
3
232412
11
232412
11
232412
11
232412
11
XEND3801
DF5
6559
2
XEND3801
DF5
6559
2
232412
11
232412
11
232412
11
232412
113
421 3
421
XESB2011
DF5
6559
XESB2011
DF5
6559
1314
1112
2324
2122
1314
1112
2324
2122
XESD1181
DF5
6559
4
XESD1181
DF5
6559
4
131412
11 3334
232422
21 4344
131412
11 3334
232422
21 4344
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/44
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control circuitsSeparate components and spare parts
References(continued) 6
Contact blocks for front mounting (1)Description Function Scheme Reference Weight
kgSpring return Slow breakOperator centres 30 or 40 mm
N/O XAC S411 0 .070
N/C XAC S412 0 .070
N/O + N/O XAC S413 0 .070
N/C + N/C XAC S414 0 .070
N/C + N/O XAC S415 0 .070
Contact blocks for base mounting (1)Description Function Scheme Reference Weight
kgSpring return Slow break
N/O XAC S4111 0 .00
N/C XAC S4121 0 .00
N/O + N/O XAC S4131 0 .00
N/C + N/C XAC S4141 0 .00
N/C + N/O XAC S4151 0 .00
Pilot light bodies for front mountingDescription Supply voltage Scheme Reference Weight
kgDirect supply Bulb not included (2)
y 400 V XAC V06 0 .050
Direct supply, through resistor Incandescent BA 9s base fitting 30 V bulb included
230 V XAC V07 0 .055
(1)MountingwithoperatingheadsZA2Bppp(seepage6/47).(2) Bulb type for use with direct supply units: BA 9s base fitting incandescent bulb U y130Vorneonbulb110Vy U y400V.
Maximumpower:2.6W,maximumØ:11mm,maximumlength:26mm.Seepage6/50.
1314
1314
XACS41p
5302
40
XACS41p
5302
40
1112
1112
1314
2324
1314
2324
1112
2122
1112
2122
2324
1112
2324
1112
1314
1314
XACS4111
5302
40
XACS4111
5302
40
1112
1112
1314
2324
1314
2324
1112
2122
1112
2122
2324
1112
2324
1112
X1
X2
X1
X2
XACV06
DF5
6559
5
XACV06
DF5
6559
5
X1
X2
X1
X2
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
Characteristics:pages 6/34
Dimensions:page 6/55
Application schemes:pages 6/56
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/45
Pendant control stations 6 Double insulated, type XAC BFor power circuits (direct switching)Separate components and spare parts
References 6
Contact blocks, snap actionDescription Application Function Max. power/
400 VScheme Reference Weight
kgDouble block 2-pole 2 spring return operators mechanically interlocked (operator centres: 40 mm)
Single-speed
N/O + N/O 2 .2 kW XES D1191 0 .40
2-speed N/O + N/O + C/O staggered auxiliary contact (1)
2 .2 kW XES D1291 0 .90
Double block 3-pole 2 spring return operators mechanically interlocked (operator centres: 40 mm)
Single-speed
N/O + N/O + N/O
3 kW XES D2201 0 .200
N/O + N/O + N/O + N/O simultaneous auxiliary contact (1)
3 kW XES D2241 0 .20
N/O + N/O + N/O + N/O staggered auxiliary contact (1)
3 kW XEN D2251 0 .20
Isolating block, slow breakIn the interests of safety, it is imperative that these isolating blocks only be used with a stay put or latching type operating head to ensure complete isolation when the pendant station is not in use .Mounting position Application Function Max.
power/400 V
Scheme Reference Weight kg
On front 40 mm centres (2)
Emergency stop
N/C + N/C + N/C with positive opening operation
3 kW XAC S399 0 .00
On front 30 mm centres (2)
Emergency stop
N/C + N/C + N/C with positive opening operation
3 kW XAC S499 0 .00
In base (3) Emergency stop
N/C + N/C + N/C with positive opening operation
3 kW XAC S3991 0 .0
(1)Auxiliarycontactsareslowbreak.(2)MountingwithoperatingheadsZA2Bppp,exceptZA2BDpandZA2BGp(seepage6/47).(3)MountingwithoperatingheadZA2BS944(seepage6/47).
1314
2324
3334
4344
1314
2324
3334
4344
1314
2324
3334
4344
1314
2324
3334
4344
XESD1191
DF5
6559
4
XESD1191
DF5
6559
4
232414
13 51
54
434434
33 61
64
5262
232414
13 51
54
434434
33 61
64
5262
1314
2324
5354
6364
3334
7374
1314
2324
5354
6364
3334
7374
XESD2201
5303
68
XESD2201
5303
68
23
1413
1453
54
2463
64
3334
7374
4344
8444
23
1413
1453
54
2463
64
3334
7374
4344
8444
23
1413
1453
54
2463
64
3334
7374
4344
8444
23
1413
1453
54
2463
64
3334
7374
4344
8444
1112
2122
3132
1112
2122
3132
XACS399
5303
69
XACS399
5303
69
1112
2122
3132
1112
2122
3132
XACS499
5303
9
XACS499
5303
9
1112
2122
3132
1112
2122
3132
XACS3991
5303
66
XACS3991
5303
66
Characteristics:pages 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/46
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuitsSeparate components and spare parts
References 6
Booted operators For use with contact block
Travel Operating temperature
Colour of insert
Sold in lots of
Unit reference Weightkg
XEN BppppXEN CppppXEN DppppXES B20XES D220XES D224XES D225
4 mm - 25…+ 70 °C (1)
White 10 XAC B9111 0 .005
Black 10 XAC B9112 0 .005
Green 10 XAC B9113 0 .005
Red 10 XAC B9114 0 .005
Yellow 10 XAC B9115 0 .005
Blue 10 XAC B9116 0 .005
Brown 10 XAC B9119 0 .005
- 40…+ 70 °C (2)
White 10 XAC B9121 0 .005
Black 10 XAC B9122 0 .005
Green 10 XAC B9123 0 .005
Red 10 XAC B9124 0 .005
Yellow 10 XAC B9125 0 .005
Blue 10 XAC B9126 0 .005
Brown 10 XAC B9129 0 .005
XES D8XES D9XES D28XES D29
6 mm - 25…+ 70 °C (1)
White 10 XAC B9211 0 .005
Black 10 XAC B9212 0 .005
Green 10 XAC B9213 0 .005
Red 10 XAC B9214 0 .005
Yellow 10 XAC B9215 0 .005
Blue 10 XAC B9216 0 .005
Brown 10 XAC B9219 0 .005
- 40…+ 70 °C (2)
White 10 XAC B9221 0 .005
Black 10 XAC B9222 0 .005
Green 10 XAC B9223 0 .005
Red 10 XAC B9224 0 .005
Yellow 10 XAC B9225 0 .005
Blue 10 XAC B9226 0 .005
Brown 10 XAC B9229 0 .005
Booted operators (silicone boot)For use with contact block
Operating temperature
Colour of boot
Reference Weightkg
XAC S4p - 25…+ 70 °C Black ZA2 BP2 0 .05
Green ZA2 BP3 0 .05
Red ZA2 BP4 0 .05
Yellow ZA2 BP5 0 .05
Blue ZA2 BP6 0 .05
(1)Polychloropreneboots.(2)Siliconeboots.
XACB911p
DF5
6559
6
XACB911p
DF5
6559
6
XACB921p
DF5
6559
7
XACB921p
DF5
6559
7
ZA2BPp
DF5
6559
8
ZA2BPp
DF5
6559
8
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/47
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuitsSeparate components and spare parts
References 6
Operating heads for front or base mounting(1)Description Colour Type Reference Weight
kgTrigger action latching Emergency stop (2) Turn to release (Emergency stop function)
Red Ø 30 mm ZA2 BS834 0 .028
Ø 40 mm ZA2 BS844 0 .033
Trigger action latching Emergency stop (2)(3) Key release (n° 455) Key withdrawal in rest (unactuated) position (Emergency stop function)
Red Ø 30 mm ZA2 BS934 0 .060
Ø 40 mm ZA2 BS944 0 .065
Selector switches, standard handle (4)
Black 2 position, stay put ZA2 BD2 0 .083 position, stay put (5) ZA2 BD3 0 .08
Key switches (key n° 455) (3) Key withdrawal in left and right-hand positions
– 2 position, stay put ZA2 BG4 0 .0423 position, stay put(5) ZA2 BG5 0 .042
Key switches (key n° 455) (3) Key withdrawal in left-hand position
– 2 position, stay put ZA2 BG2 0 .042
Key switches (key n° 455) (3)Spring return from right to left Key withdrawal in left-hand position
– 2 position ZA2 BG6 0 .042
Key switches (key n° 455) (4)(3) Key withdrawal in centre position
– 3 position, stay put (5) ZA2 BG3 0 .042
Wobblesticks (6) Operates in all directions for fast stop
Black – ZA2 BB2 0 .060Red – ZA2 BB4 0 .060
Operating head for isolating blockDescription Colour Type Reference Weight
kgMushroom head, latchingKey release (n° 455) Key withdrawal in rest (unactuated) position (Emergency stop function)
Red Ø 40 mm ZA2 BS14 0 .065
Pilot light headsDescription Colour Reference Weight
kgFor use with incandescent bulbs
Lens cap with fixing bezel White ZA2 BV01 0 .05
Green ZA2 BV03 0 .05
Red ZA2 BV04 0 .05
Yellow ZA2 BV05 0 .05
Blue ZA2 BV06 0 .05
Clear ZA2 BV07 0 .05
For use with neon bulbsLens cap with fixing bezel Green ZA2 BV033 0 .05
Red ZA2 BV043 0 .05
Yellow ZA2 BV053 0 .05
Clear ZA2 BV073 0 .05
(1)ThetechnicalcharacteristicsofpendantcontrolstationsXACBandXACMcanonlybeguaranteedbyusingtheoperatingheadsZA2Bpplistedabove.
(2)TriggeractionmechanicallylatchingEmergencystoppushbuttonsconformtostandardsEN/IEC60204-32,EN/ISO13850:2006,Machinerydirective98/37/ECandstandardEN/IEC60947-5-5.
(3) Other key numbers available on request, please consult your Regional Sales Office.(4) Selector switches or key switches with other mechanical functions: please consult your Regional Sales Office.(5)Onlysuitableforfrontmounting.(6)Basemountingrecommended.
ZA2BS844
DF5
3849
2
ZA2BS844
DF5
3849
2
ZA2BS944
DF5
3849
3
ZA2BS944
DF5
3849
3
ZA2BDp
5303
82
ZA2BDp
5303
82
ZA2BGp
5303
83
ZA2BGp
5303
83
ZA2BBp
5303
8
ZA2BBp
5303
8
ZA2BV0p
5303
90
ZA2BV0p
5303
90
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/48
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control circuitsSeparate components: pushbuttons with analogue output (1)
Characteristics 6
EnvironmentConformity to standards EN/IEC 60947-5-
Ambient air temperature For storage °C - 40…+ 70For operation °C - 25…+ 70
Degree of protection IP 65 conforming to IEC 60529
Pushbutton operator travel mm
Operating force N 4 (start of travel) 9 (end of travel)
Mechanical durability(in millions of operating cycles)
Connection mm2 Terminal connectors, maximum clamping capacity: 2 x .5 mm2 or x 2 .5 mm2
Contact block characteristicsThermal current (lthe) A 6
Rated insulation voltage (Ui) V 250, degree of pollution 3, conforming to IEC 60947-
Rated operational characteristics conforming to 947-5- Appendix CUtilisation categories AC-5 and DC-3
a.c. supply a 50/60 Hz d.c. supply cPower broken in VA for million operating cycles
Power broken in W for million operating cycles
o Inductive circuit Voltage V 48 110 230 Voltage V 48 110o VA 30 30 30 o W 48 2
Analogue circuit characteristicsType of current d .c .
Rated supply voltage V 5
Voltage limits V 4…8
Current consumption mA < 5
Analogue signal output curves and schemesAnalogue signal output curves Equivalent output schemes
with 5 V supply voltage XEA p15361 XEA p25361
Note: supplyvoltage=15V,outputvoltage=10V(ifsupplyvoltage<15V,outputvoltage<10 V)
Contact state
(1)Pushbuttonsprovidingananalogueoutputsignalproportionaltothedistancetravelledbythepushbuttonoperator.
- 10 V 0 + 10 V
XEA 15631 XEA 25361
5
10
11
Trav
el o
npu
shbu
tton
oper
ator
(
mm
)
- 10 V 0 + 10 V
XEA 15631 XEA 25361
5
10
11
Trav
el o
npu
shbu
tton
oper
ator
(
mm
)
11
12
23
2433
34
0 10 V
– 15 V
0 V
S1 kΩ
10 kΩ
11
12
23
2433
34
0 10 V
– 15 V
0 V
S1 kΩ
10 kΩ
11
12
23
2433
34
0 10 V
+ 15 V
0 V
S1 kΩ
10 kΩ
11
12
23
2433
34
0 10 V
+ 15 V
0 V
S1 kΩ
10 kΩ
23 - 2411 - 1233 - 34
0,5 mm
0 11,5 mm0,4 mm
contact closed
contact open
23 - 2411 - 1233 - 34
0,5 mm
0 11,5 mm0,4 mm
contact closed
contact open
References:page 6/49
Dimensions:page 6/49
References:page 6/49
Dimensions:page 6/49
References:page 6/49
Dimensions:page 6/49
References:page 6/49
Dimensions:page 6/49
1
2
3
4
5
6
7
8
9
10
6/49
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control circuitsSeparate components: pushbuttons with analogue output (1)
References,dimensions 6
ReferencesComplete pushbuttons (body + operating head), non booted (2)Supply voltage Contact block Reference Weight
kg0…- 5 V N/C + N/O at start of travel
N/O at end of travelXEA C15361 0 .065
0…+ 5 V N/C + N/O at start of travel N/O at end of travel
XEA C25361 0 .065
Complete pushbuttons (body + operating head), booted (2)Supply voltage Contact block Reference Weight
kg0…- 5 V N/C + N/O at start of travel
N/O at end of travelXEA B15361 0 .065
0…+ 5 V N/C + N/O at start of travel N/O at end of travel
XEA B25361 0 .065
Mounting accessoriesDescription For use with Reference Weight
kgTightening key for fixing nut XEA Cp536 ZA2 BZ905 0 .060
XEA Bp536 XAC X1 0 .00
Separate components and spare partsDescription Colour of insert Unit reference Weight
kgBooted operator (Sold in lots of 0)
White XAC B9111 0 .005
Black XAC B9112 0 .005
(1)Pushbuttonsprovidingananalogueoutputsignalproportionaltothedistancetravelledbythepushbuttonoperator.(2)Pushbuttonsuppliedwith1whiteinsertand1blackinsert.
DimensionsXEA Bp5361 XEA Cp5361
Panel cut-out
E = support panel thickness, to 3 .5 mm .(1) Minimum fixing centres between 2 operators.
XEACp5361
5303
86
XEACp5361
5303
86
XEABp5361
5303
92
XEABp5361
5303
92
ZA2BZ905
5303
06
ZA2BZ905
5303
06
XACX1
5303
05
XACX1
5303
05
XACB9112
DF5
6560
XACB9112
DF5
6560
1744
26
55
E
= =
30
1744
26
55
E
= =
30
1844
26
55
E
= =
30
1844
26
55
E
= =
30
30 (
1)
Ø22,3 +0,40
30 (
1)
Ø22,3 +0,40
Characteristics:page 6/48Characteristics:page 6/48Characteristics:page 6/48Characteristics:page 6/48
1
2
3
4
5
6
7
8
9
10
6/50
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuitsSeparate components and spare parts
References 6
BulbsDescription Voltage Sold in
lots ofUnit reference Weight
kgIncandescent BA 9s base fittingMaximum power: 2 .6 W Maximum Ø: mm Maximum length: 28 mm
6 V 10 DL1 CB006 0 .002
2 V 10 DL1 CE012 0 .002
24 V 10 DL1 CE024 0 .002
48 V 10 DL1 CE048 0 .002
30 V 10 DL1 CE130 0 .002
NeonBA 9s base fitting Maximum power: 2 .6 W Maximum Ø: mm Maximum length: 28 mm
20 V 10 DL1 CF110 0 .002
230 V 10 DL1 CF220 0 .002
400 V 10 DL1 CF380 0 .002
Accessories for booted operatorsDescription Travel Material/
ColourOperating temperature
Sold in lots of
Unit reference Weightkg
Boots with circlip, without coloured insert
4 mm Polychloroprene - 25…+ 70° C 10 XAC B911 0 .002
Silicone - 40…+ 70° C 10 XAC B912 0 .002
6 mm Polychloroprene - 25…+ 70° C 10 XAC B921 0 .002
Silicone - 40…+ 70° C 10 XAC B922 0 .002
Coloured inserts for booted operators (4 and 6 mm travel)
White – 10 XAC B901 0 .00
Black – 10 XAC B902 0 .00
Green – 10 XAC B903 0 .00
Red – 10 XAC B904 0 .00
Yellow – 10 XAC B905 0 .00
Blue – 10 XAC B906 0 .00
Brown – 10 XAC B909 0 .00
DL1Cpppp
5303
07
DL1Cpppp
5303
07
DL1CFppp
5303
08
DL1CFppp
5303
08
XACB91p
5303
XACB91p
5303
XACB92p
5303
0
XACB92p
5303
0
XACB90p
5303
09
XACB90p
5303
09
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/5
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuitsSeparate components and spare parts
References(continued) 6
Complementary accessoriesDescription For use with Reference Weight
kgProtective cable sleeve with cable tie (for tightening sleeve onto cable)
Enclosures XAC B29 and XAC B220 (2 operators)
For cable Ø 7…3 mm XAC B913 0 .065
Enclosures XAC Bppp with 4 to 2 operators and XAC Mppp with 4 and 8 operators
For cable Ø 0…22 mm XAC B960 0 .0
For cable Ø 22…35 mm XAC B965 0 .60
Blanking plug with seal and fixing nut
– ZB2 SZ3 0 .005
Adaptorfor use with protective cable sleeve for cable Ø 0…22 mm
Self-supporting cable type BBAP XAC B961 0 .025
Lower support ring Single row enclosures XAC B and XAC M XAC B971 0 .05
2 row enclosures XAC B XAC B972 0 .020
Protective guards for base mounted units
Emergency stop pushbutton XAC B982 0 .050
ToolsDescription For use with Reference Weight
kgTightening key Bezels XAC X1 0 .00
Units mounted in base of enclosure XAC X905 0 .05
Bulb extractor BA 9s base fitting bulbs XBF X13 0 .003
XACB913
5303
2
5303
3
XACB960
XACB913
5303
2
5303
3
XACB960
XACB971
5303
4
XACB971
5303
4
XACB972
DF5
6560
2
XACB972
DF5
6560
2
XACB982
DF5
6560
4
XACB982
DF5
6560
4
XACX1
5303
8
5303
9
XACX905XACX1
5303
8
5303
9
XACX905
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/52
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuitsLegends 30 x 40 mm (with symbols conforming to NF E 52-24)
References 6
Symbol Reference Symbol Reference Weight Symbol Reference Symbol Reference WeightVertical mounting 40 mm centres
Horizontal mounting 30 mm centres kg
Vertical mounting 40 mm centres
Horizontal mounting 30 mm centres kg
Raise, slow Lower, slowZB2 BY4951 ZB2 BY4901 0 .00 ZB2 BY2954 ZB2 BY2904 0 .00
Raise, fast Lower, fastZB2 BY4952 ZB2 BY4902 0 .00 ZB2 BY2955 ZB2 BY2905 0 .00
Raise, slow-fast Lower, slow-fastZB2 BY4953 ZB2 BY4903 0 .00 ZB2 BY2956 ZB2 BY2906 0 .00
Right, slow Left, slowZB2 BY4901 ZB2 BY4907 0 .00 ZB2 BY2904 ZB2 BY2910 0 .00
Right, fast Left, fastZB2 BY4902 ZB2 BY4908 0 .00 ZB2 BY2905 ZB2 BY2911 0 .00
Right, slow-fast Left, slow-fastZB2 BY4903 ZB2 BY4909 0 .00 ZB2 BY2906 ZB2 BY2912 0 .00
Forward, slow Reverse, slowZB2 BY4963 ZB2 BY4913 0 .00 ZB2 BY2966 ZB2 BY2916 0 .00
Forward, fast Reverse, fastZB2 BY4964 ZB2 BY4914 0 .00 ZB2 BY2967 ZB2 BY2917 0 .00
Forward, slow-fast Reverse, slow-fastZB2 BY4965 ZB2 BY4915 0 .00 ZB2 BY2968 ZB2 BY2918 0 .00
Slew right, slow Slew left, slowZB2 BY4919 ZB2 BY4919 0 .00 ZB2 BY2922 ZB2 BY2922 0 .00
Slew right, fast Slew left, fastZB2 BY4920 ZB2 BY4920 0 .00 ZB2 BY2923 ZB2 BY2923 0 .00
Slew right, slow-fast Slew left, slow-fastZB2 BY4921 ZB2 BY4921 0 .00 ZB2 BY2924 ZB2 BY2924 0 .00
Slow FastZB2 BY4933 ZB2 BY4933 0 .00 ZB2 BY4934 ZB2 BY4934 0 .00
Klaxon Start-KlaxonZB2 BY4982 ZB2 BY4932 0 .00 ZB2 BY4985 ZB2 BY4935 0 .00
Start StopZB2 BY4980 ZB2 BY4930 0 .00 ZB2 BY2931 ZB2 BY2931 0 .00
3040
DF5
6566
6
Vertical mounting 40 mm centres
Horizontal mounting 30 mm centres
3040
DF5
6566
6
Vertical mounting 40 mm centres
Horizontal mounting 30 mm centres
White background, black symbol
DF5
6566
5
Black background, white symbol
Red background, white symbol
White background, black symbol
DF5
6566
5
Black background, white symbol
Red background, white symbol
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/53
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuitsLegends 30 x 40 mm
References 6
Text Reference Weightkg
Text Reference Weightkg
Start functions: white characters on black backgroundStop functions: white characters on red background
bb
BlankBlack or red background
ZB2 BY2101 0 .00 White or yellow background
ZB2 BY4101 0 .00
With French text With English textFor pushbuttons For pushbuttons
Marche ZB2 BY2103 0 .00 Start ZB2 BY2303 0 .00
Arrêt ZB2 BY2104 0 .00 Stop ZB2 BY2304 0 .00
Avant ZB2 BY2105 0 .00 Forward ZB2 BY2305 0 .00
Arrière ZB2 BY2106 0 .00 Reverse ZB2 BY2306 0 .00
Montée ZB2 BY2107 0 .00 Up ZB2 BY2307 0 .00
Descente ZB2 BY2108 0 .00 Down ZB2 BY2308 0 .00
Droite ZB2 BY2109 0 .00 Right ZB2 BY2309 0 .00
Gauche ZB2 BY2110 0 .00 Left ZB2 BY2310 0 .00
En service ZB2 BY2111 0 .00 On ZB2 BY2311 0 .00
Hors service ZB2 BY2112 0 .00 Off ZB2 BY2312 0 .00
Sous tension ZB2 BY2126 0 .00 Power on ZB2 BY2326 0 .00
Lent ZB2 BY2127 0 .00 Slow ZB2 BY2327 0 .00
Vite ZB2 BY2128 0 .00 Fast ZB2 BY2328 0 .00
Klaxon ZB2 BY2125 0 .00 – – –
For selector switches For selector switchesArrêt-Marche ZB2 BY2166 0 .00 – – –
Hors-En ZB2 BY2167 0 .00 Off-On ZB2 BY2367 0 .00
With special texts Specify text when ordering,2 lines maximum, characters per line .
bb
White characters on black background
ZB2 BY2002 0 .00 Black characters on white background
ZB2 BY4001 0 .00
White characters on red background
ZB2 BY2004 0 .00 Black characters on yellow background
ZB2 BY4005 0 .00
Other versions Legends with texts in other languages .Please consult your Regional Sales Office.
DF5
6566
7
ZB2BY2101
RedWhite
Black
DF5
6566
7
ZB2BY2101
RedWhite
Black
DF5
6566
8
ZB2BY4101
YellowBlack
White
DF5
6566
8
ZB2BY4101
YellowBlack
White
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/54
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuitsTwin legends for tower cranes
References 6
Legends with white symbols on black backgroundFunction Symbol Reference Weight
kgFunction Symbol Reference Weight
kg40 mm operator centres (for enclosures with 2 to 8 operators and 2 operators in 2 rows)
HoistRaiseLower
XAC Y4970 0 .002 Long travelForwardReverse
XAC Y4972 0 .002
SlewRightLeft
XAC Y4971 0 .002 TrolleyForwardReverse
XAC Y4973 0 .002
30 mm operator centres (for enclosures with 2 operators in row)HoistRaiseLower
XAC Y3970 0 .002 Long travelForwardReverse
XAC Y3972 0 .002
SlewRightLeft
XAC Y3971 0 .002 TrolleyForwardReverse
XAC Y3973 0 .002
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
Dimensions:page 6/55
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/55
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M For control or power circuits(XAC M: products for maintenance purposes only)
Dimensions 6
Pendant control stationsXAC Bppp (2 and 3-way) XAC Bppp (2 to 2-way, row)
XAC Mppp (4 to 8-way, row)XAC Bppp (2-way, 2 rows)
Protective cable sleeves
(1)Withmushroomheadoperator.
Number of operators 2 4 6 8 12 (1 row) 12 (2 rows)b 409 499 589 679 679 593b 220 30 400 490 490 404c 98 98 98 98 98 58d 40 40 40 40 30 40
Protective guards Lower support ringsXAC B982 XAC B971, B972
74,5 85
200
265
4040
74,5 85
200
265
4040
c
d
b
b1
76
100 (1)
c
d
b
b1
76
100 (1)
76
100 (1)
c
d
b
b1
60
76
100 (1)
c
d
b
b1
60
Ø9
Ø11
Ø14
Ø7
internal Ø
Ø9
Ø11
Ø14
Ø7
internal Ø
Ø10…13
Ø13…16
Ø16…19
Ø19…22
internal Ø
Ø10…13
Ø13…16
Ø16…19
Ø19…22
internal ØØ22…26
Ø26…29
Ø29…32
Ø32…35
internal ØØ22…26
Ø26…29
Ø29…32
Ø32…35
internal Ø
4848
2424
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Application schemes:pages 6/56 and 6/57
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/56
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuits
Applicationschemes(typicalexamples) 6
Control circuitsFor control of single-speed reversing motor For control of 2-speed reversing motorContact block XES D1181 Contact block XES D1281
KM: high speed contactor
Power circuitsFor control of single-speed reversing motor. 2-phase switchingContact block XES D1191 Application example:
Combined with 3-pole isolating block XAC S399 or XAC S399, shown in the unoperated position (pendant station “supplied”), fitted with key release trigger action latching Emergency stop operator (ZA2 BS944) .
1314
1112
2324
2122
A1
A2
– KM2
– S1
A1
A2
– KM1
– S2
1314
1112
2324
2122
A1
A2
– KM2
– S1
A1
A2
– KM1
– S2
3443
44
13 33
14
1112
2324
2122
A1
A2
– KM2
A1
A2
– KM
– S1
A1
A2
– KM1
– S2
3443
44
13 33
14
1112
2324
2122
A1
A2
– KM2
A1
A2
– KM
– S1
A1
A2
– KM1
– S2
– S1
L1 L2 L3
– S2
1314
2324
3334
4344
U WV11 21 31
12 22 32
Q
– S1
L1 L2 L3
– S2
1314
2324
3334
4344
U WV11 21 31
12 22 32
Q
– S1
L1 L2 L3
– S2
1314
2324
3334
4344
U WV
– S1
L1 L2 L3
– S2
1314
2324
3334
4344
U WV
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/57
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuits
Applicationschemes(typicalexamples)(continued) 6
Power circuits(continued)For control of 2-speed reversing motor (motors with separate windings only). 2-phase switchingContact block XES D1291 Application example:
Combined with 3-pole isolating block XAC S399 or XAC S399, shown in the unoperated position (pendant station “supplied”), fitted with key release trigger action latching Emergency stop operator (ZA2 BS944) .
For control of single-speed reversing motor. 3-phase switching, reversing by 2-phase inversionContact block XES D2201 Contact block XES D2241 with line contactor
– S1
– S2
54
L1
1112
L2
2122
Q
1314
2324
5152
3334
4344
6162 64
U2
V2
W2
U1
V1
W1
Y
L3
3132
– S1
– S2
54
L1
1112
L2
2122
Q
1314
2324
5152
3334
4344
6162 64
U2
V2
W2
U1
V1
W1
Y
L3
3132
L1 L2 L3
– S1
– S2
1314
2324
5152
3334
4344
6162 64
U2
V2
W2
U1
V1
W1
Y
54L1 L2 L3
– S1
– S2
1314
2324
5152
3334
4344
6162 64
U2
V2
W2
U1
V1
W1
Y
54
L1 L2 L3
1314
2324
3334
5354
6364
7374
– S1
– S2
Y
U V W
L1 L2 L3
1314
2324
3334
5354
6364
7374
– S1
– S2
Y
U V W
A1
A1
L1 L2 L3
1314
2324
3334
5354
6364
7374
12
24
36
– S1
– S2
U V W
– F1 21
4344
8444
– KM1
Y
A1
A1
L1 L2 L3
1314
2324
3334
5354
6364
7374
12
24
36
– S1
– S2
U V W
– F1 21
4344
8444
– KM1
Y
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
Characteristics:pages 6/34 and 6/36
References:pages 6/35 to 6/54
Dimensions:page 6/55
Presentation:page 6/58
1
2
3
4
5
6
7
8
9
10
6/58
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC MFor control or power circuits
Presentation 6
ZB2 SZ3
ZA2 BV0 p
ZB2 BYpppp
ZB2 BY pppp
ZB2 BYpppp
XAC B911p
XAC B921p
ZA2 BBp
ZA2 BGp
ZA2 BDp
ZA2 BS934
ZA2 BS844
ZA2 BS944
ZA2 BS834
ZA2 BS844
ZA2 BS944
XAC B982
XAC S3991
XAC S499
XAC S399
XAC S41p
XAC S41p1
XAC V0 p
XES B2011
XEN C1111XEN D2611
XEN D3801
XEN B1181
XES D1pp 1
XES D22p 1
XEA B p5361
XEA Cp 5361
ZB2 SZ3
ZA2 BV0 p
ZB2 BYpppp
ZB2 BY pppp
ZB2 BYpppp
XAC B911p
XAC B921p
ZA2 BBp
ZA2 BGp
ZA2 BDp
ZA2 BS934
ZA2 BS844
ZA2 BS944
ZA2 BS834
ZA2 BS844
ZA2 BS944
XAC B982
XAC S3991
XAC S499
XAC S399
XAC S41p
XAC S41p1
XAC V0 p
XES B2011
XEN C1111XEN D2611
XEN D3801
XEN B1181
XES D1pp 1
XES D22p 1
XEA B p5361
XEA Cp 5361
1
2
3
4
5
6
7
8
9
10
6/59
Pendant control stations 6 Double insulated, type XAC B Metal, type XAC M (XAC M: products for maintenance purposes only) For control or power circuitsVariable composition stations, factory assembled
Orderform(specimensuitableforphotocopying) 6
Customer Schneider Electric IndustriesCompany Order N° Delivery date Sales office - Subsidiary Co. Order N°
Enter the order with XAC B09 reference (for enclosures XAC B) or XAC M09 reference (for enclosures XAC M)
Unit reference of empty enclosure, see pages 6/39 to 6/4 Number of identical stations Enclosure price (1)
XAC
Legendssee pages 6/52 to 6/54
Contact blocks or pilot light bodiessee pages 6/42 to 6/45
Operating heads or pilot light heads or blanking plug see pages 6/46 and 6/47
Reference Unit price Reference Unit price Reference Unit price Total price1
2
3
4
5
6
7
8
9
10
11
12
Unit mounted in base of enclosure (if required)13
Factory assembled: Number of heads or blanking plugs to be fitted
Additional cost XAC 9VA for fitting of 1 head or 1 blanking plug
X
Complementary accessories, see page 6/5 (cross the appropriate box or boxes)Description Reference Unit price
14 Adaptor for self-supporting cable type BBAP for use with cable entry sleeve Ø 0 to 22 mm
XAC B961
15 Lower support ring for single row enclosures XAC B971
15 Lower support ring for 2 row enclosures XAC B972
16 Protective guard for key release latching mushroom head pushbutton, mounted in base
XAC B982
Total price of assembled pendant station
(1)Obtaintheemptyenclosureprice.
14
1316
1211
910
78
65
34
12
5303
43
12 cut-outs, centres: 40 mm
14
1316
1211
910
78
65
34
12
5303
43
12 cut-outs, centres: 40 mm
14
15138
7
65
43
21
5256
84
2 to 8 cut-outs, centres: 40 mm
14
15138
7
65
43
21
5256
84
2 to 8 cut-outs, centres: 40 mm
14
1513
87654321
9101112
5256
85
12 cut-outs, centres: 30 mm
14
1513
87654321
9101112
5256
85
12 cut-outs, centres: 30 mm
1
2
3
4
5
6
7
8
9
10
Top Related