Wires & Cables
Area
Cond.Min.No.ofWires
Thicknessof EBXL /
XLPEInsulation
(Nom.)
ApproxOverall
diameter
Approx.NetWt.ofCable
Max.D.CResistanceat 20 deg.C
Current RatingFor EBXL -XLPECables (125°C)
Directin
Ground
Current RatingFor Chemically Cured XLPE Cables (90°C)
ShortCircuitRating
for 1secDirectin
Ground
Thicknessof PVCInner
Sheath
Dimensionof
ArmWire
Thicknessof
OuterSheath
Area
Cond.Min.No.ofWires
Thicknessof EBXL /
XLPEInsulation
(Nom.)
ApproxOverall
diameter
Approx.NetWt.ofCable
Max.D.CResistanceat 20 deg.C
Current RatingFor EBXL -XLPECables (125°C)
Directin
Ground
InDuct
InAir
Current RatingFor Chemically Cured XLPE Cables (90°C)
ShortCircuitRating
for 1 secDirect
inGround
InDuct
InAir
Sq.mm Nos mm mm Kg/Km Ω/KM
Dimensionof
Armstrips
Thicknessof
OuterSheath
mm mm Cu Cu Cu Cu Cu Cu Cu
Product Construction
Wires & Cables
üConductor : Annealed Plain copper conductor complying with BS 6360 üInsulation : Electron Beam Cross Linked Polyethylene 120°CüArmour : GI StripsüJacket : PVC Complying with BS 6746
Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467
Application
Features
Technical Data
üOperating Temperature : -15°C to +120°C High Insulation resistance at elevated temperature üShort Circuit Temperature : 280°CüBending radius (min) : 12 x Cable diaüRated Voltage :600/1000 VüTest Voltage : 3.5 kV for 5 mins.üSpecification : BS 5467
PartNumber
749E3002
749E3202
749E3402
749E3702
749E3802
749E4102
749E4202
749E4402
749E4602
749E4802
749E4902
25
35
50
70
95
120
150
185
240
300
400
7
7
19
19
19
37
37
37
61
61
61
0.9
0.9
1.0
1.1
1.1
1.2
1.4
1.6
1.7
1.8
2.0
1.6
1.7
1.8
1.9
2
2.1
2.2
2.4
2.5
2.5
2.5
28.7
32.6
37.3
42.5
48.0
52.8
58.4
64.8
72.1
79.4
89.7
1274
1623
2068
2642
3341
4015
4813
5830
7148
8620
10895
3.6
5.0
7.1
10.0
13.6
17.1
21.4
26.4
34.3
42.9
57.1
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.9991
0.0754
0.0601
0.0470
198
234
273
343
408
451
511
576
660
745
803
178
211
255
309
368
417
472
530
606
683
770
173
203
281
317
387
432
495
576
680
770
872
152
180
210
264
314
347
393
443
508
573
618
137
162
196
238
283
321
363
408
466
525
592
133
156
216
244
298
332
381
443
523
592
671
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
0.8 X 4
üTransmission and distribution of Power Industrial unitsüCommercial and residential placesü Indoor and outdoor usesüCable ducts, cable trays conduits Direct burial and underground burial where mechanical damage risk for cables.
üElectron Beam Cross Linked.üEnhanced Mechanical, Electrical, Thermal & Weathering properties.üSoldering iron resistantüResistance to corona effect.üEasy jointing & terminationüBetter resistance to most chemicals & acidsüLow direct electric losses.üHigh current carrying capacity.
Siechem 2 Core APC Conductor EBXL - XLPE 120°C Insulated GI Strips Armoured PVC Sheathed 600/1000 V Power cable as per BS 5467
Cable conforming to IEC 60502 & VDE-0271 also available according to customer requirement.
749E
Catalogue No
www.siechem.com
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
34
CM/L-6819184
IS : 7098 (Pt.1)IS : 7098 (Pt.1)
OHSAS 18001
AS 9100
ISO45001
ISO 9001
ISO 14001