Download - Well Heads

Transcript
Page 1: Well Heads

Cameron Conventional Surface Wellheads

WR6563-TC1261 Conv Brochure 1/14/99 1:56 PM Page 2

Page 2: Well Heads

Table of Contents

Cameron Conventional Wellhead SystemsSelecting a Wellhead System ..........................................1Major Considerations for Casing Hanger Selection..........1S Wellhead System..........................................................2

S Casing Head Housings ............................................4S Casing Head Spools ................................................4S Casing Hangers ......................................................6

IC Wellhead System ........................................................3IC-2 Casing Head Housings........................................8IC-2 Casing Head Spools............................................8IC Casing Hangers ..................................................10

Cameron Tubing Spools and HangersSelecting a Completion System ....................................12Major Considerations for Tubing Hanger Selection........12Single Completions

C Tubing Spool ........................................................13Tubing Hangers..................................................14, 15

Dual CompletionsCD-2 Tubing Spool ..................................................16Tubing Hangers ........................................................17

Critical Service ApplicationsMTBS Tubing Spool ..................................................18MTBS Tubing Hanger ..............................................18

Auxiliary EquipmentCasing Head Housing Bottom Connections ..................19

Casing Box Thread ..................................................19Slip-on Weld ............................................................19CAMFORGE™ Casing Connection System ..............19SlipLock™ Casing Connection System......................19

Secondary Seals ......................................................20, 21Lock Screws ..................................................................21Test Ports ......................................................................21Injection Ports ..............................................................21

WR6563-TC1261 Conv Brochure 1/14/99 1:56 PM Page 3

Page 3: Well Heads

Cameron Conventional Wellhead Systems

1

Cameron Conventional Wellhead Systems provide the flexibility,compatibility and interchangeability required for a wide range of surface applications. With the proven features of Cameronsystems comes reduced inventory requirements, lower costs andthe ability to provide standard components.

Cameron provides two Conventional Wellhead Systems, the S Wellhead and IC Wellhead. The Cameron S ConventionalWellhead System offers the industry’s highest capacity conven-tional spool-type wellhead and is designed for use with all welldepths and types of completions. The IC Wellhead is a cost-effective, reliable system for a variety of applications. Althoughcomponents are not interchangeable, the S Wellhead may be usedin place of the IC Wellhead for all applications. In addition, bothwellheads are compatible with most Cameron tubing spool andhanger configurations.

Cameron has earned a reputation for quality wellhead productsthat meet or exceed API 6A specifications. Cameron offers acomplete line of conventional wellheads and Christmas trees tosuit all casing and tubing programs for working pressures up to30,000 psi. Equipment for surface applications ranges from lowpressure, conventional equipment to systems for severe serviceand geothermal applications. For equipment requirements notcovered in this brochure, contact your Cameron representative.

Selecting a Wellhead System

The first step in determining which Cameron wellhead system is best for your application is to determine the casing hangerstyle to be used. Each hanger profile is unique and is generallycompatible with only a limited number of casing head/spoolbowls. Cameron has a complete line of slip-type casing hangersdivided into two segments, SB and IC, each serving differentapplications.

Casing Hanger Selection Chart

API

TEMPERATURE

RANGE

250°F121°C

180°F82°C

150°F65°C

100°F38°C

50°F10°C

0°F-17°C-20°F-29°C

0 10% 20% 30% 40% 50% 60% 70% 80%

U T S P

Hang-Off Capacity (% of Pipe Body Yield)

(Operating conditions verified by API 6A, 17th Edition, Appendix F testing)

SB-5

SB-3

Major Considerations for Casing Hanger Selection

• Temperature Range

-20°F to 150°F (-29°C to 65°C) . . . . . . . . . . .IC-1, IC-1-P, IC-2 -20°F to 180°F (-29°C to 82°C) . . . . . . . . . . . . . . . . . . . . .SB-6 -20°F to 250°F (-29°C to 121°C) . . . . . . . . . . . . .SB-3 and SB-5Note: Although final production may be at one temperature, operating temperature at the casing hanger may be lower.

• Hang-Off Capacity

Up to 50% of pipe body yield . . . . . . . . . . .IC-1, IC-1-P, IC-2Up to 70% of pipe body yield . . . . . . . . . . . . . . . . . . . . . .SB-6Up to 80% of pipe body yield . . . . . . . . . . . . . . . . .SB-3, SB-5

• Working Pressure

5000 psi WP . . . . . . . . . . . . . . . . . . . . . . . . . . .IC-1, SB-3, SB-610,000 psi WP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IC-1-P, IC-210,000 and 15,000 psi WP . . . . . . . . . . . . . . . . . . . . . . . . .SB-5

• Method to Set Annulus Seal

Manual . . . . . . . . . . . . . . . . . . . .SB-3, SB-5, SB-6, IC-1, IC-1-PAutomatic . . . . . . . . . . . . . . . . . . . . . . . .SB-3, SB-5, SB-6, IC-2

• Seal Replaceable with Load on Hanger

Yes . . . . . . . . . . . . . . . . . . . . . . . SB-3, SB-5, SB-6, IC-1, IC-1-PNo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .IC-2

• Spool/Housing Compatibility

Single 45° shoulder (IC-2 Series) . . . . . . . . .IC-1, IC -1P, IC-2Double 45° shoulder (S Series) . . . . . . . . . . . .SB-3, SB-5, SB-6

IC -1IC-1-PIC-2

SB-6

WR6563-TC1261 Conv Brochure 1/14/99 1:56 PM Page 4

Page 4: Well Heads

2

Cameron S Wellhead System

S Conventional Wellhead SystemThe Cameron S Conventional Wellhead System offers the industry’s highest capacityconventional spool-type wellhead and is designed for use with all well depths and all types of completions. The Cameron S Wellhead incorporates the lower casinghead housing and hanger and the subsequent casing head spools and hangers. Thiswellhead is the preferred wellhead for the conditions noted below. It is compatiblewith any of the Cameron tubing spool and hanger configurations shown on pages12-18.

Features: Two 45° shoulders. Upper shoulder supports the pack-off hydraulic pressure and testloads. Lower shoulder provides independent support for the casing load. Selectionof secondary seals and pack-off bushings provide versatility.

Working Pressure: Up to 15,000 psi (Excluding tubing spool)Operating Temperatures: -20°F to +250°F (-29°C to +121°C)Hang-Off Capacity: Up to 80% of pipe body yieldCasing Head Housings: S, S-11, S-3 (See page 4)Casing Head Spools: S, S-11, S-3 (See page 4)Casing Hangers: SB-3, SB-5, SB-6 slip and seal assemblies

(See page 6)Tubing Spools and Hangers: C tubing spool: HT, HT-2, T, T-CL,

C-SRL, CXS hangersMTBS tubing spool: MTBS hangerCD-2 tubing spool: CD-2, CD-T,

CD-T-CL hangers

S Casing Hanger Application Chart

API

TEMPERATURE

RANGE

250°F121°C

180°F82°C

150°F65°C

100°F38°C

50°F10°C

0°F-17°C

-20°F-29°C

0 10% 20% 30% 40% 50% 60% 70% 80%

U T S P

Hang-Off Capacity (% of Pipe Body Yield)

(Operating conditions verified by API 6A, 17th Edition, Appendix F testing)

SD24383

N Lock Screw

T Tubing Hanger

Tubing Spool

NX Bushing

SB-3 Casing Hanger

S Casing Head Spool

Double P Seal

S Casing Head Housing

SB-3 Casing Hanger

SB-5

SB-3

SB-6

Cameron Conventional Wellhead Systems

WR6563-TC1261 Conv Brochure 1/14/99 1:57 PM Page 5

Page 5: Well Heads

3

Cameron IC Wellhead System

IC Casing Hanger Application Chart

IC Conventional Wellhead SystemThe Cameron IC Conventional Wellhead System incorporates the lower casing head housing and hanger and the subsequent casing head spools and hangers. This wellhead is the preferred wellhead for the conditions noted below. Althoughcomponents are not interchangeable, the S Wellhead may be used in place of the IC Wellhead for these applications as well. Both wellheads are compatible with anyof the Cameron tubing spool and hanger configurations shown on pages 12-18.

Features: Straight-bore design with 45° load shoulder. Selection of secondary seals and pack-off bushings provide versatility.

Working Pressure: Up to 10,000 psi (Excluding tubing spool)Operating Temperatures: -20°F to +150°F (-29°C to +65°C)Hang-Off Capacity: Up to 50% pipe body yieldCasing Head Housings: IC-2, IC-2-BP (See page 8)Casing Head Spools: IC-2, IC-2-BP, IC-2-L (See page 8)Casing Hangers: IC-1, IC-1P, IC-2 slip and seal assemblies

(See page 10)Tubing Spools and Hangers: C tubing spool: HT, HT-2, T, T-CL,

C-SRL, CXS hangersMTBS tubing spool: MTBS hangerCD-2 tubing spool: CD-2, CD-T,

CD-T-CL hangers

API

TEMPERATURE

RANGE

150°F65°C

100°F38°C

50°F10°C

0°F-17°C-20°F-29°C

0 10% 20% 30% 40% 50% 60% 70% 80%

U T S P

Hang-Off Capacity (% of Pipe Body Yield)

(Operating conditions verified by API 6A, 17th Edition, Appendix F testing)

IC-1IC-1-PIC-2

N Lock Screw

T Tubing Hanger

Tubing Spool

NX Bushing

IC-2 Casing Hanger

IC-2 Casing Head Spool

Single P Seal

IC-2 Casing Head Housing

IC-2 Casing Hanger

SD24384

Cameron Conventional Wellhead Systems

WR6563-TC1261 Conv Brochure 1/14/99 1:57 PM Page 6

Page 6: Well Heads

CXS(Single)

CD-SRL(Single)

CD-2(Dual)

CD-T(Dual)

CD-T-CL(Dual)

MTBS(Metal)

HT-2(Single)

HT(Single)

CD-2(Single or Dual Completions)

MTBS(Metal)

C(Single Completions Only)

S IC-2

T-CL(Single)

T(Single)

Single P Double P Single T Double T NX BushingCANH™

(For use with S spool only)

IC-1* IC-1-P* IC-2SB-3 SB-5* SB-6

IC-1* IC-1-P* IC-2SB-3 SB-5* SB-6

S/IC-2 S-11/IC-2-BP

S

CAMFORGE™ CR Landing Base(Optional)

Casing BoxThread

Slip-On Weldwithout O-Ring

Slip-On Weldwith O-Ring(Standard)

Slip Lock

S-3/IC-2-L

Casing HangersThree slip-type casing hangersare available for the S and IC Casing Head Housings. Eachhanger has a specific applica-tion. In addition, there are mandrel-type casing hangersavailable for both bowl types.

Casing HangersThree slip-type casing hangerdesigns are available for the Sand IC-2 Casing Spools. Eachhanger has specific applications.In addition, there are mandrel-type casing hangers available for both bowl types.

Bottom ConnectionsThe S and IC-2 Casing Head Housings are available with a selection of bottom connections to match installation requirements.

CR Landing BaseThe CR landing base canbe used with any stylehousing to transfer loadsto the conductor.

Casing Head HousingThe S and IC-2 Casing Head Housings have several options for top connections. One option features no lock screws; another features two lock screws 180°apart; and the final option features multiple lock screws depending on the flange size.

Secondary SealsA variety of secondary seals areavailable to fit S and IC-2 CasingSpools as well as the C, CD-2and MTBS Tubing Spools.

Tubing HangersTubing hangers are available for single, dual and metal-sealing completions.

Tubing SpoolsTwo tubing spool designs are available for standard service applications. The CD-2 Tubing Spool has the same bowl configuration as the C Tubing Spool and is compatible with dual tubing hangers. The MTBS Spool is all-metal-sealing for critical applications.

Casing SpoolsThe S and IC-2 Casing Spoolshave several options for top connections. One option features no lock screws; anotherfeatures two lock screws 180°apart; and the final option features multiple lock screwsdepending on the flange size.

IC-2

S/IC-2 S-11/IC-2-BP S-3/IC-2-L

Top flange lock screw configurations available for S and IC-2 Casing Spools.*Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

Top flange lock screw configurations available for S and IC-2 Casing Head Housings.*Note: Lock screws may not be used with SB-5, IC-1 or IC-1-P slips.

Cameron Conventional Wellhead Systems

Bottom Connections available for S and IC-2 Casing Head Housings

WR6563/TC1261 Fold out 1/15/99 9:30 AM Page 1

Page 7: Well Heads

The S Casing Head Housing seals off the surface casing and provides a landing bowl for the next casing string as well as anattachment for the BOP stack. The S Casing Spool seals off thesurface casing string and its landing bowl provides support forthe next casing string.

• Bowl Design

Dual 45° shoulder design provides capability to hang heavycasing strings without damage. The upper shoulder supportspack-off hydraulic pressure and test loads while the lowershoulder provides independent support for the casing load.

• Casing Hanger Compatibility

Compatible with the SB-3, SB-5 and SB-6 Casing Hangerseries. See pages 6 and 7 for more information.

• Lock Screw Configurations

S Housings and Spools are available with or without Type NLock Screws in the top flange as follows: S Housing and Spool - no lock screws.S-11 Housing and Spool - two lock screws 180° apart for reten-tion of the wear bushing during drilling.S-3 Housing and Spool - a full compliment of lock screws usedfor retention of the casing hanger (exact number dependent onflange size). See page 21 for more information on Type NLock Screws.

• Side Outlets

Available with line pipe threaded and studded outlets.Studded outlets are threaded for valve removal plugs.

• Housing Bottom Connections

S Housings are available with casing box threads, slip on weld(with and without O-ring), SlipLock and CAMFORGE bottomconnections. See page 19 for more information.

• Secondary Seals

S Spools are available with Single and Double P, Single andDouble T, NX Bushing and CANH secondary seals. Spoolssupplied with CANH secondary seals are not intended for useover spools other than Cameron S type. See page 20 for moreinformation.

• Test and Injection Ports

All test ports are metal sealing and are designed to allow vent-ing. Injection ports include buried check valves. See page 21for more information.

• Landing Base

Type CR landing bases can be provided to transfer loads tothe conductor. These landing bases do not require welding tothe casing head housing.

S Casing Head Housings and Spools

4

S Casing Head Housing S Casing Head Spool

SD17055 SD17056

7-12 1/14/99 3:54 PM Page 1

Page 8: Well Heads

5

S Casing Head Housings and Spools

S Casing Head Housing Dimensions

Top Flange Outlets

Nominal Size WP Casing Size Threaded Studded Dimensions (in.) Dimensions (mm)

(in.) (psi) (in.) Size (in.) Size (in.) WP (psi) A B C A B C

9 2000 8-5/8 2 2-1/16 2000 16.62 10.25 8.00 422.15 260.35 203.209 3000 8-5/8 2 2-1/16 5000 17.88 10.62 8.00 454.15 269.75 203.20

11 3000 8-5/8 2 2-1/16 5000 20.50 12.50 8.03 520.70 317.50 203.9611 3000 9-5/8 2 2-1/16 5000 20.50 12.50 8.91 520.70 317.50 226.3111 3000 10-3/4 2 2-1/16 5000 20.50 12.50 9.95 520.70 317.50 252.7311 5000 8-5/8 2 2-1/16 5000 19.25 12.81 8.03 488.95 325.37 203.9611 5000 9-5/8 2 2-1/16 5000 19.25 12.81 8.91 488.95 325.37 226.3111 5000 10-3/4 2 2-1/16 5000 19.25 12.81 9.95 488.95 325.37 252.73

13-5/8 3000 11-3/4 2 2-1/16 5000 19.31 11.00 10.91 490.47 279.40 277.1113-5/8 3000 13-3/8 2 2-1/16 5000 18.00 11.00 12.62 457.20 279.40 320.5513-5/8 5000 11-3/4 2 2-1/16 5000 19.50 12.81 10.91 495.30 325.37 277.1113-5/8 5000 13-3/8 2 2-1/16 5000 19.50 12.81 12.62 495.30 325.37 320.55

16-3/4 3000 16 2 2-1/16 2000 17.50 11.21 15.12 444.50 284.73 384.05

21-1/4 3000 20 2 2-1/16 2000 20.25 11.25 19.00 514.35 285.75 482.6021-1/4 3000 18-5/8 2 2-1/16 5000 20.25 13.62 17.62 514.35 345.95 447.5521-1/4 3000 20 2 2-1/16 5000 20.25 13.62 19.00 514.35 345.95 482.6021-1/4 5000 20 2 2-1/16 5000 24.32 16.00 19.00 617.73 406.40 482.60

S Casing Head Spool Dimensions

Top Flange Bottom Flange Outlets

Nominal Size WP Nominal Size WP Threaded Studded Dimensions (in.) Dimensions (mm)

(in.) (psi) (in.) (psi) Size (in.) Size (in.) WP (psi) A B C A B C

11 3000 13-5/8 3000 2 2-1/16 5000 20.75 9.94 10.00 527.05 252.48 254.0011 5000 11 3000 2 2-1/16 5000 26.25 12.88 10.00 666.75 327.15 254.0011 5000 11 5000 2 2-1/16 5000 26.25 12.88 10.00 666.75 327.15 254.0011 5000 13-5/8 3000 2 2-1/16 5000 26.00 13.44 10.00 660.40 341.38 254.0011 5000 13-5/8 5000 2 2-1/16 5000 26.31 13.63 10.00 668.27 346.20 254.0011 5000 16-3/4 3000 2 2-1/16 5000 26.25 13.12 10.00 666.75 333.25 254.0011 10,000 11 10,000 2 2-1/16 10,000 31.25 15.38 10.00 793.75 390.65 254.0011 10,000 13-5/8 5000 2 2-1/16 10,000 29.25 14.88 10.00 742.95 377.95 254.0011 10,000 13-5/8 10000 2 2-1/16 10,000 29.88 14.06 10.00 758.95 357.12 254.00

13-5/8 5000 13-5/8 5000 2 2-1/16 5000 26.50 13.25 12.62 673.10 336.55 320.5513-5/8 5000 20-3/4 3000 2 2-1/16 5000 25.25 12.25 12.62 641.35 311.15 320.55

Dimensional Data:

A = Maximum heightB = Height from centerline of outlet to top of flangeC = Maximum through bore

Note: All dimensions are estimates and finished dimensions may vary.

Note: C dimensions for spools may be smaller in order to match casing ID.S Housing S Spool

SD24645 SD24646

7-12 1/14/99 3:55 PM Page 2

Page 9: Well Heads

Cameron S Casing Head Spools and Housings accept all threehangers in the SB hanger family. SB hangers can be loweredthrough the BOP as soon as the cement plug hits bottom. Once inplace, they support the entire casing weight and seal the annulus.Mandrel style casing hangers can also be supplied.

The unique slip design of the SB family of hangers achievescontrolled friction when precision-machined slips with sharpinner teeth securely bite casing, while dull outer teeth on the backside contact the slip bowl. Because these hangers are installed inthe double 45° shoulder housing design, the mechanical load iscompletely separated from the hydraulic load. This allows theassembly to hold full test pressure while varying the slip loadfrom zero to full joint strength without changing deflection of casing in the pressured zone.

• SB-3 Casing Hanger

The SB-3 Casing Hanger is a wrap-around slip and sealassembly designed for 5000 psi WP service. It is rated for ahang-off capacity of 80% of pipe body yield. Like the otherslips in the SB family, it requires a load of only 15,000 lb to setthe seal. In addition, the seal can be re-energized by tighten-ing the cap screws. The seal can be replaced with the fullrated load on the hanger.

• SB-5 Casing Hanger

The SB-5 Casing Hanger is a wrap-around slip and sealassembly designed for 10,000 and 15,000 psi WP service. It is rated for a hang-off capacity of 80% of pipe body yield.Like the other slips in the SB family, it requires a load of only 15,000 lb to set the seal. In addition, the seal can be

re-energized by tightening the cap screws. The seal can bereplaced with the full rated load on the hanger. The SB-5 CasingHanger can only be used in the Type S spool (i.e. cannot be usedwith spools supplied with lock screws).• SB-6 Casing Hanger

The SB-6 Casing Hanger is a wrap-around slip and sealassembly designed for 5000 psi WP service. It is rated for ahang-off capacity of 70% of pipe body yield. Like the otherslips in the SB family, it requires a load of only 15,000 lb to set the seal. In addition, the seal can be re-energized bytightening the cap screws. The seal can be replaced with thefull rated load on the hanger.

Casing Hangers for S Casing Head Housings and Spools

6

SB-3 Casing Hanger

SB-5 Casing Hanger SB-6 Casing Hanger

SD24654

SD24655 SD24656

7-12 1/14/99 3:55 PM Page 3

Page 10: Well Heads

7

Casing Hangers for S Casing Head Housings and Spools

SB Casing Hanger Comparison

Spool Hanger Operating Working Rated Load Method to Seal ReplaceableModel Compatibility Type Temperature Pressure (psi) Capacity Set Seal with

Load on Hanger

SB-3 S, S-11, S-3 Wrap-Around -20° to 250°F 5000 80% minimum Casing Weight YesSlip and Seal -29° to 121°C pipe body yield or Manual

Assembly

SB-5 S Wrap-Around -20° to 250°F 10,000/15,000 80% minimum Casing Weight YesSlip and Seal -29° to 121°C pipe body yield or Manual

Assembly

SB-6 S, S-11, S-3 Wrap-Around -20° to 180°F 5000 70% minimum Casing Weight YesSlip and Seal -29° to 82°C pipe body yield or Manual

Assembly

SB-6 Casing Hanger S-11 Casing Head Spool

SD24647 SD24648

7-12 1/14/99 3:55 PM Page 4

Page 11: Well Heads

IC-2 Casing Head Housings and Spools

8

The IC-2 Casing Head Housing seals off the surface casing andprovides a landing bowl for the next casing string as well as anattachment for the BOP stack. The IC-2 Casing Spool seals offthe surface casing string and its landing bowl provides supportfor the next casing string.

• Bowl Design

A straight bore with a single 45° shoulder design providessupport for the casing load and reduces the risk of bowl damage due to drill stem rotation. This design minimizeshoop load on the housing while maintaining high hangingcapacity.

• Casing Hanger Compatibility

Accommodates a wide variety of slip-type and mandrel hangers including the IC-1, IC-1-P and IC-2. See pages 10 and 11 for more information.

• Lock Screw Configurations

IC-2 Housings and Spools are available with or without Type N Lock Screws in the top flange as follows:

IC-2 Housing and Spool - no lock screws.

IC-2-BP Housing and Spool - two lock screws 180° apartfor retention of the wear bushing during drilling.

IC-2-L Housing and Spool - a full complement of lockscrews used for retention of the casing hanger (exact number dependent on flange size).

See page 21 for more information on Type N Lock Screws.

• Side Outlets

Available with line pipe threaded and studded outlets.Studded outlets are threaded for valve removal plugs.

• Housing Bottom Connections

IC-2 Housings are available with casing box threads, slip onweld (with and without O-ring), SlipLock and CAMFORGEbottom connections. See page 19 for more information.

• Secondary Seals

IC-2 Spools are available with Single and Double P, Singleand Double T, and NX Bushing secondary seals. See page 20for more information.

• Test and Injection Ports

All test ports are metal sealing and are designed to allow venting. Injection ports include buried check valves. See page 21 for more information.

• Landing Base

Type CR landing bases can be provided to transfer loads tothe conductor. These landing bases do not require welding to the casing head housing.

IC-2 Casing Head Housing IC-2 Casing Head Spool

SD17058 SD17057

7-12 1/14/99 3:56 PM Page 5

Page 12: Well Heads

9

IC-2 Casing Head Housings and Spools

IC-2 Housing IC-2 Spool

Dimensional Data:

A = Maximum heightB = Height from centerline of outlet to top of flangeC = Maximum through bore

Note: All dimensions are estimates and finished dimensions may vary.

Note: C dimensions for spools may be smaller in order to match casing ID.

IC-2 Casing Head Housing Dimensions

Top Flange Outlets

Nominal Size WP Casing Size Threaded Studded Dimensions (in.) Dimensions (mm)

(in.) (psi) (in.) Size (in.) Size (in.) WP (psi) A B C A B C

9 2000 8-5/8 2 2-1/16 2000 16.62 10.25 8.00 422.15 260.35 203.209 3000 8-5/8 2 2-1/16 5000 17.88 10.62 8.00 454.15 269.75 203.20

11 3000 8-5/8 2 2-1/16 5000 20.50 12.50 8.03 520.70 317.50 203.9611 3000 9-5/8 2 2-1/16 5000 20.50 12.50 8.91 520.70 317.50 226.3111 3000 10-3/4 2 2-1/16 5000 20.50 12.50 9.95 520.70 317.50 252.7311 5000 8-5/8 2 2-1/16 5000 19.25 12.81 8.03 488.95 325.37 203.9611 5000 9-5/8 2 2-1/16 5000 19.25 12.81 8.91 488.95 325.37 226.3111 5000 10-3/4 2 2-1/16 5000 19.25 12.81 9.95 488.95 325.37 252.73

13-5/8 3000 11-3/4 2 2-1/16 5000 19.31 11.00 10.91 490.47 279.40 277.1113-5/8 3000 13-3/8 2 2-1/16 5000 18.00 11.00 12.62 457.20 279.40 320.5513-5/8 5000 11-3/4 2 2-1/16 5000 19.50 12.81 10.91 495.30 325.37 277.1113-5/8 5000 13-3/8 2 2-1/16 5000 19.50 12.81 12.62 495.30 325.37 320.55

16-3/4 3000 16 2 2-1/16 2000 17.50 11.21 15.12 444.50 284.73 384.05

21-1/4 3000 20 2 2-1/16 2000 20.25 11.25 19.00 514.35 285.75 482.6021-1/4 3000 18-5/8 2 2-1/16 5000 20.25 13.62 17.62 514.35 345.95 447.5521-1/4 3000 20 2 2-1/16 5000 20.25 13.62 19.00 514.35 345.95 482.6021-1/4 5000 20 2 2-1/16 5000 24.32 16.00 19.00 617.73 406.40 482.60

IC-2 Casing Spool Dimensions

Top Flange Bottom Flange Outlets

Nominal Size WP Nominal Size WP Threaded Studded Dimensions (in.) Dimensions (mm)

(in.) (psi) (in.) (psi) Size (in.) Size (in.) WP (psi) A B C A B C

11 3000 13-5/8 3000 2 2-1/16 5000 20.75 9.94 10.00 527.05 252.48 254.0011 5000 11 3000 2 2-1/16 5000 26.25 12.88 10.00 666.75 327.15 254.0011 5000 11 5000 2 2-1/16 5000 26.25 12.88 10.00 666.75 327.15 254.0011 5000 13-5/8 3000 2 2-1/16 5000 26.00 13.44 10.00 660.40 341.38 254.0011 5000 13-5/8 5000 2 2-1/16 5000 26.31 13.63 10.00 668.27 346.20 254.0011 5000 16-3/4 3000 2 2-1/16 5000 26.25 13.12 10.00 666.75 333.25 254.0011 10,000 11 10,000 2 2-1/16 10,000 31.25 15.38 10.00 793.75 390.65 254.0011 10,000 13-5/8 5000 2 2-1/16 10,000 29.25 14.88 10.00 742.95 377.95 254.0011 10,000 13-5/8 10000 2 2-1/16 10,000 29.88 14.06 10.00 758.95 357.12 254.00

13-5/8 5000 13-5/8 5000 2 2-1/16 5000 26.50 13.25 12.56 673.10 336.55 319.0213-5/8 5000 20-3/4 3000 2 2-1/16 5000 25.25 12.25 12.56 641.35 311.15 319.02

SD24649 SD24650

7-12 1/14/99 3:56 PM Page 6

Page 13: Well Heads

Cameron IC-2 Casing Head Spools and Housings accept all threehangers in the IC hanger family. IC hangers offer a selection ofmanually energized seals or weight set seals, depending uponapplication requirements. They also offer a choice of one-pieceand two-piece design so that use of IC-2 equipment for differentapplications can be varied by slip selection alone. IC Hangersland on the single 45° shoulder in IC-2 bowls. Mandrel style casing hangers can also be supplied.

• IC-1 Casing Hanger

The IC-1 Casing Hanger is an independent slip and sealassembly. The slip assembly is latched around the casing andlowered into the casing head. The seal assembly is installedover the casing after it is cut-off. Pressure applied to the topof the seal assembly is transferred to the casing head, not theslips. This hanger can only be used in the IC-2 bowl profile(i.e. cannot be used with spools provided with lock screws).

• IC-1-P Casing Hanger

The IC-1-P Casing Hanger is a one-piece, non-automatic,wrap-around hanger which is ideal for use where casingweight is insufficient to energize the hanger seal. The seal isenergized using cap screws and can be replaced with ratedload on the hanger. This hanger can only be used in theIC-2 bowl profile (i.e. cannot be used with spools providedwith lock screws).

• IC-2 Casing Hanger

The IC-2 Casing Hanger is a wrap-around hanger with anannulus seal which is energized by casing weight. Theweight to energize the seal varies with the casing and slipsize. The hanger uses a heavy duty latch and hinge designwhich creates a reliable, strong and stable hanger structureafter closing. The hinge mechanism enables the hangerhalves to pivot out of the way during “wrap-around.”Tapered “rough backs” allow a quick, secure bite of thecasing, restrict continued downward movement, and prevent collapse of the casing. A guide ring maintains slip alignment during installation and operation.

Casing Hangers for IC-2 Casing Head Housings and Spools

10

IC-1 Casing Hanger

IC-1-P Casing Hanger IC-2 Casing Hanger

SD24659 SD24658

SD24657

WR6563-TC1261 Conv Brochure 1/14/99 2:08 PM Page 13

Page 14: Well Heads

11

Casing Hangers for IC-2 Casing Head Housings and Spools

IC Casing Hanger Comparison

Spool Hanger Operating Working Rated Load Method Seal ReplaceableModel Compatibility Type Temperature Pressure (psi) Capacity to Set Seal with

Load on Hanger

IC-1 IC-2 Independent -20° to 150°F 5000 50% minimum O-rings YesSlip and Seal -29° to 65°C pipe body yield

Assembly

IC-1-P IC-2 Wrap-around -20° to 150°F 10,000 50% minimum Cap Screws YesSlip and Seal -29° to 65°C pipe body yield

Assembly

IC-2 IC-2, IC-2-BP, IC-2-L Wrap-around -20° to 150°F 10,000 50% minimum Casing Weight NoSlip and Seal -29° to 65°C pipe body yield

Assembly

IC-2 Casing Hanger IC-2 Casing Head Spool

SD24651 SD24510

WR6563-TC1261 Conv Brochure 1/14/99 2:08 PM Page 14

Page 15: Well Heads

Cameron offers a wide variety of tubing spools and hangers forall types of completions: single, dual, high pressure, and severeservice.

The standard Cameron C bowl design is utilized in both theC and CD-2 Tubing Spool designs. Use of this profile as standardallows Cameron to offer the widest possible array of tubing hang-er choices while minimizing tubing spool requirements. Of thetubing hangers offered all but one, the MTBS (designed for criti-cal service applications), fit the C profile.

Like our wellhead components, all Cameron completion com-ponents meet or exceed API 6A specifications. Included in theseproducts is a complete line of completion equipment andChristmas trees to suit all tubing programs for working pressuresup to 30,000 psi. Equipment for surface applications range fromlow pressure, conventional equipment to systems for severe ser-vice and geothermal applications. For completion equipment notcovered in this brochure, contact your Cameron representative.

Selecting a Completion System

The first step in determining which Cameron completion systemis best for your application is to determine the tubing hangerstyle to be used. Each hanger profile is unique and is generallycompatible with only a limited number of casing head/spoolbowls.

Major Considerations for Tubing Hanger Selection

• Completion Type

Single . . . . . . . . . .HT, HT-2, T, T-CL, C-SRL-CL, CXS, MTBSDual . . . . . . . . . . . . . . . . . . . . . . . . . . . .CD-2, CD-T, CD-T-CL

• Tubing Hanger Type

Coupling Assembly . . . . . . . . . . . . . . . . . . . . . . . . . .HT, HT-2Mandrel . . . . . . . . . . . . . . . . .T, T-CL, C-SRL-CL, CXS, MTBSSplit Dual Split Mandrel . . . . . . . . . . . .CD-2, CD-T, CD-T-CL

• Working Pressure

5000 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CXS, CD-210,000 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .HT, HT-2 15,000 psi . . . . . . . . . . . . .T, T-CL, C-SRL-CL, CD-T, CD-T-CL20,000 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MTBS

• Annulus Seal Type

Elastomer . . . . . . . . . . . . . . . . .HT, HT-2, T, T-CL, C-SRL-CL, . . . . . . . . . . . . . . . . . . . . . . . . . . . .CXS, CD-2, CD-T, CD-T-CLMetal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MTBS

• Neck Seal Type

Elastomer . . . . . . . . . . . . . . . . . . . . . . . .HT, HT-2, CXS, CD-2Metal . . . . . . . . . .T, T-CL, C-SRL-CL, CD-T, CD-T-CL, MTBS

• Control Line Capability

No . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .HT, HT-2, T, CD-TStandard, continuous . . . .T-CL, C-SRL-CL, MTBS, CD-T-CLOptional, non continuous . . . . . . . . . . . . . . . . . . . .CXS, CD-2

Cameron Tubing Spools and Hangers

12

Tubing Spool, Tubing Hanger Compatibility Chart

Tubing Hangers Tubing Spools

C CD-2 MTBS

HT Tubing Hanger Assembly • •

HT-2 Tubing Hanger Assembly • •

T Tubing Hanger • •

T-CL Tubing Hanger • •

C-SRL-CL Tubing Hanger • •

CXS Tubing Hanger • •

MTBS Tubing Hanger •

WR6563-TC1261 Conv Brochure 1/14/99 2:09 PM Page 15

Page 16: Well Heads

13

C Tubing Spool Dimensions

C Tubing Spool

The C Tubing Spool is Cameron’s standard spool for single completions in 7-1/16” and 9” nominal top flange sizes. For 11”and 13-5/8” nominal tubing spools, the IC-2-L Spool is utilized.Features include:

• Bowl Design

A straight bore with a single 45° shoulder design providessupport for the tubing load and reduces the risk of bowl damage due to drill stem rotation. This design minimizeshoop load on the spool while maintaining high hangingcapacity.

• Tubing Hanger Compatibility

Accommodates a wide variety of tubing hangers for singlecompletions including HT, HT-2, C-SRL-CL, T, T-CL, and CXSdesigns. See pages 14 and 15 for more information.

• Type N Lock Screws

Reliable Type N Lock Screws feature packing installed in frontof the threads. This prevents contamination of threads bywellbore fluids and helps eliminate build-up of solids behindthe screw. See page 21 for more information on Type N LockScrews.

• Side Outlets

Available with line pipe threaded and studded outlets.Studded outlets are threaded for valve removal plugs.

• Secondary Seals

C Tubing Spools are available with Single and Double P,Single and Double T, and NX Bushing and CANH secondaryseals. See page 20 for more information.

• Test and Injection Ports

All test ports are metal sealing and are designed to allowventing. Injection ports include buried check valves. Seepage 21 for more information.

Cameron Tubing Spools and Hangers

C Tubing Spool

Bottom Flange Top Flange Outlets

Nominal Size WP Nominal Size WP Threaded Studded Dimensions (in.) Dimensions (mm)

(in.) (psi) (in.) (psi) Size (in.) Size (in.) WP (psi) A B C A B C

11 2000 7-1/16 3000 2 2-1/16 3000 20.88 10.30 6.81 530.23 261.62 173.0411 3000 7-1/16 3000 2 2-1/16 3000 20.88 10.30 6.81 530.23 261.62 173.0411 3000 7-1/16 5000 2 2-1/16 5000 22.00 11.44 6.81 558.80 290.58 173.0411 3000 9 5000 2 2-1/16 5000 22.56 12.10 8.22 573.09 307.34 208.7911 3000 7-1/16 5000 2 2-1/16 5000 25.00 11.44 6.81 635.00 290.58 173.0411 5000 7-1/16 10,000 2 2-1/16 10,000 25.00 11.85 6.77 635.00 300.99 171.9611 5000 9 5000 2 2-1/16 5000 22.56 11.13 8.22 573.09 282.70 208.7911 10,000 7-1/16 10,000 2 2-1/16 10,000 25.50 11.50 6.77 647.70 292.10 171.96

Dimensional Data:

A = Maximum heightB = Height from centerline of outlet to top

of flangeC = Maximum through bore

Note: All dimensions are estimates and finished dimensions may vary.

Note: Spool through bore may be smaller to match casing ID.

C Spool

SD17073

SD24653

WR6563-TC1261 Conv Brochure 1/14/99 2:09 PM Page 16

Page 17: Well Heads

14

Tubing Hangers for Single Completions

Model Spool Hanger Working Method to Annulus Neck Control BPVCompatibility Type Pressure Set Seal Seal Seal Line Preparation

HT C and CD-2 Coupling Assembly with 10,000 Radial Elastomer Elastomer Not Available StandardType C Wrap-Around Hanger Interference

HT-2 C and CD-2 Rotatable Coupling Assembly 10,000 Radial Elastomer Elastomer Not Available Standardwith Type C Wrap-Around Hanger Interference

T C and CD-2 Mandrel 15,0001 Lock Screws Elastomer Metal Not Available Standard

T-CL C and CD-2 Mandrel 15,0001 Lock Screws Elastomer Metal Continuous Standard

C-SRL-CL C and CD-2 Mandrel 15,000 Lock Screws Elastomer Metal Continuous Standard

CXS C and CD-2 Mandrel 5000 Lock Screws Elastomer Elastomer Optional Standard

MTBS MTBS Mandrel 20,000 Lock Screws Metal Metal Continuous Standard

Comparison of Tubing Hangers for Single Completions

The HT and HT-2 Tubing Hanger Assemblies are all single com-pletion hanger assemblies for use in either the C Tubing Spool orthe CD-2 Tubing Spool. Both designs are made up of a coupling,adapter and Type C wrap-around style casing hanger. The HT-2also includes a suspension nut which allows installation withoutrotating the Christmas tree. The HT-2 is preferred for stainlesssteel hanger and adapter applications due to decreased risk ofgalling. Both assemblies are rated up to 10,000 psi WP and aresimple and quick to install without special running tools.

• HT and HT-2 Couplings

Both designs include coarse ACME threads which make upeasily with minimum risk of damage. Self-energizing sealsisolate threads from well fluids, allowing testing of flange ring gasket.

• HT and HT-2 Adapters

Both adapter top and bottom connections are normally configured with a flanged bottom and studded top. Thedesigns provides a test port for verification of adapter flangeconnection and coupling seal integrity.

• HT-2 Suspension Nut

The HT-2 Suspension nut is made of a high-strength, low-alloy, gall resistant material. A coupling seal isolates the nutfrom flow pressure, preventing corrosion.

• C Tubing Hanger

The C Tubing Hanger is a wrap-around slip and seal assembly.The annulus seal is energized by tubing weight or tiedownscrews and controls pressure in the casing annulus duringinstallation of the Christmas tree.

HT Tubing Hanger Assembly HT-2 Tubing Hanger Assembly

HT Coupling

HT Adapter

C Tubing Hanger

C Tubing Hanger

HT-2 Suspension Nut

HT-2 Adapter

HT-2 Coupling

HT and HT-2 Tubing Hanger Assemblies

1 Not recommended for use in 7-1/16” 10,000 psi Type C Spools.

SD24660

SD24661

WR6563-TC1261 Conv Brochure 1/14/99 2:09 PM Page 17

Page 18: Well Heads

15

The T, T-CL, C-SRL-CL and CXS Tubing Hangers are all singlecompletion, mandrel-type hangers for use in either the C TubingSpool or the CD-2 Tubing Spool.

• T Tubing Hanger

The T Tubing Hanger withstands stress of high pressure, corrosive/erosive elements associated with well flow. Its flexible neck maintains the metal seal despite thermal or pressure cycling.

• T-CL Tubing Hanger

The T-CL Tubing Hanger withstands stress of high pressure,corrosive/erosive elements associated with well flow. Acontrol line exit block is available in either a bull plug style or block needle valve style.

• C-SRL-CL Tubing Hanger

The C-SRL-CL Tubing Hanger incorporates a pressure ener-gized SRL neck seal which accommodates vertical movementin the tubing hanger during BOP testing. A control line exitblock is available in either a bull plug style or block needlevalve style. The C-SRL-CL hanger should be used in 7-1/16”10,000 psi Type C Tubing Spools.

• CXS Tubing Hanger

The CXS Tubing Hanger includes two neck seals which maybe used to isolate one control line.

Tubing Hangers for Single Completions

T Tubing Hanger

C-SRL-CL Tubing HangerCXS Tubing Hanger

T-CL Tubing Hanger

T, T-CL, C-SRL-CL and CXS Tubing Hangers

SD24662 SD24663

SD24665

SD24664

WR6563-TC1261 Conv Brochure 1/14/99 2:10 PM Page 18

Page 19: Well Heads

Tubing Spools for Dual Completions

16

The CD-2 Tubing Spool features the same bowl as the C TubingSpool but incorporates alignment pins for dual completions. TheCD-2 can also be used for single completions by retracting thealignment pins. Features include:

• Bowl Design

A straight bore with a single 45° shoulder design providessupport for the tubing load and reduces the risk of bowl damage due to drill stem rotation. This design minimizeshoop load on the spool while maintaining high hangingcapacity.

• Tubing Hanger Compatibility

Accommodates a wide variety of tubing hangers for singlecompletions including HT, HT-2, C-SRL-CL, T, T-CL, and CXSdesigns for single completions and the CD-2, CD-T and CD-T-CL hangers for dual completions.

• Type N Lock Screws

Reliable Type N Lock Screws feature packing installed in frontof the threads. This prevents contamination of threads bywellbore fluids and helps eliminate build-up of solids behindthe screw. See page 21 for more information.

• Alignment Pins

Alignment pins for dual completions are located below theload shoulder to avoid test plug interference and providealignment without reducing load shoulder capacity.

• Side Outlets

Available with line pipe threaded and studded outlets.Studded outlets are threaded for valve removal plugs.

• Secondary Seals

CD-2 Tubing Spools are available with Single and Double P,Single and Double T, and NX Bushing secondary seals. Seepage 19 for more information.

• Test and Injection Ports

All test ports are metal sealing and are designed to allowventing. Injection ports include buried check valves. Seepage 21 for more information.

CD-2 Tubing Spool

CD-2 Tubing Spool

Dimensional Data:

A = Maximum heightB = Height from centerline of outlet to top

of flangeC = Maximum through bore

Note: All dimensions are estimates and finished dimensions may vary.

Note: Spool through bore may be smaller to match casing ID.

CD-2 Tubing Spool Dimensions

Bottom Flange Top Flange Outlets

Nominal Size WP Nominal Size WP Threaded Studded Dimensions (in.) Dimensions (mm)

(in.) (psi) (in.) (psi) Size (in.) Size (in.) WP (psi) A B C A B C

11 2000 7-1/16 3000 2 2-1/16 3000 20.88 10.30 6.81 530.23 261.62 173.0411 3000 7-1/16 3000 2 2-1/16 3000 20.88 10.30 6.81 530.23 261.62 173.0411 3000 7-1/16 5000 2 2-1/16 5000 22.00 11.44 6.81 558.80 290.58 173.0411 3000 9 5000 2 2-1/16 5000 22.56 12.10 8.22 573.09 307.34 208.7911 3000 7-1/16 5000 2 2-1/16 5000 25.00 11.44 6.81 635.00 290.58 173.0411 5000 7-1/16 10,000 2 2-1/16 10,000 25.00 11.85 6.77 635.00 300.99 171.9611 5000 9 5000 2 2-1/16 5000 22.56 11.13 8.22 573.09 282.70 208.7911 10,000 7-1/16 10,000 2 2-1/16 10,000 25.50 11.50 6.77 647.70 292.10 171.96

SD17074

SD24666

CD-2 Spool

WR6563-TC1261 Conv Brochure 1/14/99 2:16 PM Page 19

Page 20: Well Heads

17

Cameron’s dual completion tubing hangers include three designs:the CD-2 Tubing Hanger, CD-T Tubing Hanger and CD-T-CLTubing Hanger. These hangers are used with the CD-2 TubingSpool.

These hangers are split dual mandrel style hangers which can berun and pulled independently. Alignment slots located below theload shoulder protect the alignment pins and allow maximumload capacity.

• CD-2 Tubing Hanger

The CD-2 Tubing Hanger is a two-piece mandrel hangerwhich provides a reliable, economical elastomer seal for usewith pressures up to 10,000 psi. It is available with one or twocontinuous control lines per string.

• CD-T Tubing Hanger

The CD-T Tubing Hanger is a one-piece mandrel style hangerwith a tapered metal-to-metal neck seal for superior sealingup to 15,000 psi.

• CD-T-CL Tubing Hanger

The CD-T-CL Tubing hanger is identical to the CD-T TubingHanger except that it includes standard control line exits forone or two continuous control lines per string.

Tubing Hangers for Dual Completions

Comparison of Tubing Hangers for Dual Completions

CD-2 Tubing Hanger CD-T Tubing Hanger CD-T-CL Tubing Hanger

CD-2, CD-T, CD-T-CL Tubing Hangers

Model Spool Hanger Working Method to Annulus Neck Control BPVCompatibility Type Pressure Set Seal Seal Seal Line Preparation

CD-2 CD-2 Split Dual Mandrel (two piece) 10,000 Lock Screws Elastomer Elastomer Optional, Continuous Standard

CD-T CD-2 Split Dual Mandrel( one piece) 15,000 Lock Screws Elastomer Metal Not Available Standard

CD-T-CL CD-2 Split Dual Mandrel (one piece) 15,000 Lock Screws Elastomer Metal Standard, Continuous Standard

SD24667 SD24668 SD24669

WR6563-TC1261 Conv Brochure 1/14/99 2:17 PM Page 20

Page 21: Well Heads

18

MTBS Spool Dimensions

The MTBS Tubing Spool is a single completion, metal-to-metalsealing spool for critical service applications to 20,000 psi WP.Features include:

• Metal-to-Metal SealingThe MTBS Tubing Spool and MTBS Tubing Hanger providecomplete metal-to-metal sealing. The annulus seal is radiallysqueezed into contact with parallel cylindrical sealing surfacesin the spool bore. The annulus and neck seals are simultane-ously pressure-energized with flange makeup. The annulusseal is retrieved when the hanger is pulled from mating bowlpreparation.

• MTBS Tubing HangerThe MTBS Tubing Hanger is made of high alloy materials towithstand corrosive and high temperature environments. Theextended neck ensures positive alignment for the seal duringinstallation. The hanger is reusable and the metal seals arereplaceable.

• Bowl DesignA straight bore bowl design provides a large through bore andallows a 7-1/16” flange to be used over a 7-5/8” casing string.

• Type N Lock ScrewsReliable N Lock Screws feature packing installed in front of the threads. This prevents contamination of threads bywellbore fluids and helps eliminate build-up of solids behindthe screw. See page 21 for more information on N LockScrews.

• Side OutletsMTBS Spools are available with studded outlets threaded forvalve removal plugs.

• Secondary SealsMTBS Tubing Spools are available with Single and Double P,Single and Double T, and NX Bushing and CANH secondaryseals. See page 20 for more information.

• Test and Injection PortsAll test ports are metal sealing and are designed to allow vent-ing. Injection ports include buried check valves. See page 21for more information.

Tubing Spools and Hangers for Critical Service Applications

MTBS Tubing Spool

MTBS Tubing Hanger

MTBS Tubing Spool and MTBS Tubing Hanger

Top Flange Bottom Flange Outlets

Nominal Size WP Nominal Size WP Threaded Studded Dimensions (in.) Dimensions (mm)

(in.) (psi) (in.) (psi) Size (in.) Size (in.) WP (psi) A B C A B C

7-1/16 10,000 11 5000 2 2-1/16 10,000 25.00 11.87 6.38 635.00 301.50 162.057-1/16 10,000 11 10,000 2 2-1/16 10,000 24.88 11.50 6.38 631.95 292.10 162.057-1/16 15,000 11 10,000 2 2-1/16 15,000 25.50 12.13 6.31 647.70 308.10 160.277-1/16 15,000 11 15,000 2 2-1/16 15,000 32.00 15.00 6.31 812.80 381.00 160.277-1/16 20,000 11 15,000 2 2-1/16 20,000 32.25 15.75 6.25 819.15 400.05 158.75

9 15,000 11 10,000 2 2-1/16 15,000 30.50 15.50 7.25 774.70 393.70 184.159 15,000 11 15,000 2 2-1/16 15,000 32.00 15.50 7.25 812.80 393.70 184.159 15,000 13-5/8 10,000 2 2-1/16 15,000 32.00 15.50 7.25 812.80 393.70 184.15

11 10,000 13-5/8 5000 2 2-1/16 10,000 29.25 14.88 9.88 742.95 377.95 250.9511 10,000 13-5/8 10,000 2 2-1/16 10,000 29.88 14.00 9.88 758.95 355.60 250.9511 15,000 13-5/8 10,000 2 2-1/16 15,000 32.62 16.62 9.85 828.55 422.15 250.19

Dimensional Data:

A = Maximum heightB = Height from centerline of outlet to top

of flangeC = Maximum through bore

Note: All dimensions are estimates and finished dimensions may vary.

Note: Spool through bore may be smaller to match casing ID.

SD24670

SD24672

SD24671

MTBS Spool

WR6563-TC1261 Conv Brochure 1/14/99 2:17 PM Page 21

Page 22: Well Heads

19

SlipLock Casing Connection System

CAMFORGE Casing Connection System

Casing Box Thread Slip-On Weldwithout O-Ring

Slip-On Weldwith O-Ring

Auxiliary Equipment

• SlipLock™ Casing Connection System

The SlipLock Casing Connection System is a simple slip mechanism which reduces installation time because welding iseliminated. Sealing is achieved with elastomeric P Seals. TheSlipLock system can be used for working pressures up to10,000 psi and is reusable for exploration wells.

• CAMFORGE™ Casing Connection System

The CAMFORGE Casing Connection System requires nowelding and no premachining of casing. The casing ismechanically cut so that existing production does not have tobe shut in. The connection is made using hydraulic pressureto expand the surface casing and housing. The system estab-lishes a pressure-tight, metal sealing connection suitable forworking pressures up to 10,000 psi. The CAMFORGE systemminimizes rig time and duration of open hole time withoutBOP protection. Annulus hydro-testing simulates workingconditions prior to BOP nipple up.

• Slip-On Weld

Slip on weld bottom connections are standard with O-rings forboth S and IC-2 casing heads with 10-3/4” or smaller casingpreparations. For larger casing sizes, the O-ring seal option isnot available. If utilized, the O-ring seal requires only oneexternal weld. Slip-on weld connections include a 1/2” linepipe test port to validate the integrity of both the weld andthe O-ring seals.

• Casing Box Thread

Casing threads are intended for use where threaded connections are specified for casing heads. In this case, the lower connection outside diameter is standardizedwhere possible to allow use of raw material for either S or IC-2 style heads.

Casing Head Housing Bottom Connection Options

SD016801 SD24673

SD24674 SD24674SD24675

WR6563-TC1261 Conv Brochure 1/14/99 2:17 PM Page 22

Page 23: Well Heads

20

Auxiliary Equipment

Cameron offers a wide range of secondary seals for use in casingand tubing spools. These secondary seals are installed in the bottom of spools with corresponding preps.

• Single and Double P Seals

The Single and Double P Seals are ideal for use as crossoverswhere moderately severe service is expected. Each P Seal consists of a large elastomer seal with separate anti-extrusionrings. Both Single and Double P Seals are sized to accommo-date the tolerance range of casing and may be used onmachined hanger necks. Double P Seals can be tested withpressure applied between the seals.

• Single and Double T Seals

Single and Double T Seals are interference-fit, elastomericseals for use with casing sizes 10-3/4” and smaller. They areideal for use as crossovers where moderately severe service is expected. Both Single and Double T Seals are sized toaccommodate the tolerance range of casing and may be usedon machined hanger necks. Double T Seals can be tested withpressure applied between the seals.

• NX Bushing

NX Bushings accommodate variations in casing programs.The NX Bushing utilizes a P seal and is retained in the spoolwith a retainer wire. Either integral or separate bit guides can be provided.

• CANH™ Seal

The CANH Seal is a metal-to-metal crossover seal which hasbeen designed for severe service and corrosive environments.This seal can be installed and tested on standard “rough” pipewith minimal cleanup. Field machining is not required in normal applications. Its simple, flange-energized designachieves a gas-tight seal. Sealing occurs at four nibs machinedinto the inner and outer seal rings. Note: The CANH Seal isnot recommended for use with IC-2 slips. Spools equippedwith CANH Seal bottoms require special CANH Seal supportrings when making up to an IC-2 Spool.

Secondary Seals Comparison Chart

Double P SealSingle P Seal

Double T SealSingle T Seal

Secondary Seals

Model Casing Spool Tubing Spool Maximum Working Seal Type Means of Compatibility Compatibility Service Rating Pressure (psi) Energizing Seal

Single P Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 5000 Elastomeric Plastic Packing

Double P Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 15,000 Elastomeric Plastic Packing

SIngle T Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Standard 3000 Elastomeric Radial Interference

Double T Seal S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 5000 Elastomeric Radial Interference

NX Bushing S, S-11, S-3, IC-2, IC-2-BP, IC-2-L C, CD-2, MTBS Moderately Severe 5000 Elastomeric Plastic Packing

CANH Seal S, S-11, S-3 C, CD-2, MTBS Severe/Corrosive 20,000 Metal Flange Make-up

SD24677

SD24679

SD24678

SD24680

WR6563-TC1261 Conv Brochure 1/14/99 2:18 PM Page 23

Page 24: Well Heads

Test Port

Injection Port (15,000 psi WP and Above)

21

Auxiliary Equipment

NX Bushing CANH Seal

Lock Screws, Test Ports and Injection Ports

• N Lock Screw

All Cameron spools and housings utilize N Lock Screws.This design features packing in front of the threads to helpprevent contamination of the threads by wellbore fluids and eliminate build-up of solids behind screw which couldprevent proper retraction. An external oil seal protectsthreads from atmospheric corrosion. N Lock Screws are field replaceable.

• Test Ports

All test ports in Cameron conventional wellhead equipmentare the API 6A Type II metal seal design for safety and relia-bility. These ports are applicable to all pressure ratings andcan be safely vented.

• Injection Ports

For casing and tubing spools which require injection ofsealant in order to energize or re-energize the secondary seal,two styles of fittings are available. Each style has a buriedball check (without spring). For applications 10,000 psi WPand below, the port features a simple plug with a 1” NPTthread. For working pressures above 10,000 psi WP, plugsincorporate a two-piece plug with a pressure vent.

Injection Port (10,000 psi WP and Below)

N Lock Screw

SD24681 SD24682

SD24683

SD24684

SD24686SD24685

WR6563-TC1261 Conv Brochure 1/14/99 2:18 PM Page 24

Page 25: Well Heads

© Cooper Cameron Corporation, Cameron Division, Printed in USA, 11/98, TG/5M, WR6563/TC1261

Western Hemisphere

Cameron

PO Box 1212

Houston Texas 77251-1212

Tel 713 939 2211

Fax 713 939 2620

http://www.camerondiv.com

Eastern Hemisphere

Cooper Cameron (U.K.) Ltd.

5 Mondial Way

Harlington

Hayes UB3 5AR

Tel 44 181 9901800

Fax 44 181 9901888

http://www.camerondiv.com

Asia Pacific/Middle East

Cooper Cameron (Singapore) Pte. Ltd.

No. 2 Gul Circle, Jurong Industrial Est

Locked Bag Service No. 3

Jurong Town Post Office

Singapore 629560

Republic Of Singapore

Tel 65 8613355

Fax 65 8616197

http://www.camerondiv.com

Cameron, CAMFORGE, SlipLock and CANH are trademarks of Cooper Cameron Corporation.

WR6563-TC1261 Conv Brochure 1/14/99 1:55 PM Page 1