Scientific
JohnMorris John Morris Scientific
Service plus Solutions
2
Free Call: 1800 251 799 Australia www.johnmorris.com.au
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Different Applications Require Specialised Pumps
John Morris Scientific is proud to be the authorised distributor of Vacuubrand vacuum systems in Australia, New Zealand & the South Pacific Region.
Vacuubrand is the world leader in vacuum technology & offer the most comprehensive range of vacuum pumps, state-of-the-art vacuum gauges plus vacuum controllers (for rough & fine vacuum) to meet your individual requirements.
This brochure contains information to help you select the right equipment for your application.
The pumping speed of all Vacuubrand pumps is measured according to ISO 21360 plus production conforming to ISO 9001 & ISO 14001
To ensure you select the right equipment for your needs, simply contact John Morris Scientific for professional assistance.
Selecting the Right Pump for Your Application • Rotary/Parallel Evaporation Page 3• Rotational Vacuum Concentrators Page 4• Vacuum Drying Oven Page 4• Gel Drying Page 5• Filtration & SPE Page 5• Local Vacuum Networks (VACUU-LAN) Page 6• Freeze Drying/Schlenk Line Page 7• Turbo Backing Page 7• Liquid Aspiration Page 8Overview of Pump Types Page 9Vacuum Gauges & Controllers Page 10Benefits of Vacuubrand Diaphragm Pumps Page 11
INDEX
20
5
1
10-3
High Vacuum
Pum
ping
Spe
ed (m
3 /hou
r)
Application Chart
Low VacuumUltimate Vacuum (mbar)
1 100
Local Vacuum Networks (VACUU-LAN)
Vacuum Drying Oven
Rotational Vacuum Concentrator
Rotary/Parallel Evaporation
Turbo Backing
Freeze Drying
Gel Drying
Filtration & SPE
Liquid Aspiration
Chemistry Diaphragm Pumps
Recommended Pump Type per Application
LEGEND
Chemistry Hybrid Pumps
Rotary Vane Vacuum Pumps
Diaphragm Pumps
Liquid Aspiration Systems
Schlenk Line
3
Toll Free: 0800 651 700 New Zealand www.jms.co.nz
Selecting the Right Pump for Your ApplicationThis section provides an overview of the process & pump requirements for each separate application to assist you in selecting the most appropriate pump - plus examples of our most popular pumps.
Many more pump options are available from John Morris Scientific for each separate application - simply contact us for more details
Base
Pum
p
Ulti
mat
e Va
cuum
mba
r (w
ithou
t gas
bal
last
)
Chem
ical
Res
istan
t
AK EK Man
ual C
ontr
ol
VARI
O C
ontr
ol
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Ulti
mat
e Va
cuum
mba
r (w
ith g
as b
alla
st)
Pum
ping
Spe
ed
(m3 /h
) 50
Hz
Model
Process Requirements
Rotary/ Parallel Evaporation
Pump Requirements
Comments
For teaching/low boiling solvents- - -
-
-
-
-
-
-
-
Our best selling Rotary Evaporator Pump for general use
Includes vacuum control & manometer on pump
High boilers, fully automatic with speed control, shorter process times - see page 11 for more details
Perfect for controlling 2 x Rotary Evaporators simultaneously
MZ 1C
• Mediumtohighvacuum• Fast&highlysensitivevacuumcontrolwithsamplesthat tendto‘superheat’orfoam• Vacuumcontrolforshortprocesstimes&high reproducibility• Optimumcondensationinrotaryevaporatorcooler• Recoveryofresidualsolventvapoursafterthepump
M = Diaphragm (membrane) pump E = Single pump stage (up to 70 mbar) Z = Two pump stages (up to 7 mbar)D = Three pump stages (up to 1.5 mbar) V = Four pump stage (up to 0.6 mbar) NT = Pumps comprising the New Technology
LEGEND - Pump specification terminology abbreviations for each application
C = Chemistry design (with fluoropolymer flowpath)TE = Dry ice or water ice cooled emission condenser for solvent recovery
AK = Separator catchpot for inlet/outlet condensates,collectsparticles&dropletsPC = ‘Pumping Unit, Chemistry’ - Chemistry pump with vacuum control & solvent recovery
EK = Exhaust vapour (emission) condenser for ≈100%solventrecoverySYNCHRO = Pumping unit for simultaneous operationof2independentvacuum applicationsby1pump
• Excellentchemical&condensatecompatibility• Effectivegasballastsystemtopreventcondensationinthepump• Verygoodultimatevacuumevenwithgasballastoperationfor continuousevaporation• Lowultimatevacuumforlowevaporationtemperaturesorhigh boilingsolvents• Emissioncondenserforsolventrecovery&minimiseairpollution• ATEXCat3approvalforvapourpathtopreventignitionof flammablesolvents
MZ 2C NT+AK+EK
PC 101 NT
PC 3001 VARIO
Pro
PC 520 NT
-
MZ 2C NT
MZ 2C NT
MD 1C VARIO
-SP
MZ 2C NT
12
7
7
2
7
20
12
12
4
12
0.75
2.0
2.0
2.0
2.0
Chemistry Diaphragm Pumps are the most suitable (refer product recommendations below)
4
Free Call: 1800 251 799 Australia www.johnmorris.com.au
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Model
Process Requirements
Rotational Vacuum Concentrators
Pump Requirements
CommentsBase
Pum
p
Ultim
ate
Vacu
um m
bar
(with
out g
as b
alla
st)
Chem
ical R
esist
ant
AK EK Man
ual C
ontro
l
VARI
O C
ontro
l
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Ultim
ate
Vacu
um m
bar
(with
gas
bal
last
)
Pum
ping
Spe
ed
(m3 /h
) 50
Hz
Our best selling Chemical Vacuum Pump for general use
-
-
-
-
- For larger/ high volume concentrators
High boilers, fully automatic with speed control, shorter process times
MZ 2C NT+AK+EK
• Mediumtohighvacuum• Optimumheattransfertosamplevessel• Fast&highlysensitivevacuumcontrolwithsamplesthat tendto‘superheat’orfoam• Vacuumcontrolforshortprocesstimes&high reproducibility• Optimumcondensationincoolerofvacuumpump• Recoveryofresidualsolventvapoursafterthepump
• Excellentchemical&condensatecompatibility• Effectivegasballastsystemtopreventcondensationinthepump• Verygoodultimatevacuumevenwithgasballastoperationfor continuousevaporation• Highpumpingspeeds• Lowultimatevacuumforhighboilingsolvents• Inletseparator&emissioncondenserforsolventrecovery&to minimiseenvironmental/labairpollution• ATEXCat3approvalforvapourpathtopreventignitionof flammablesolvents
MD 4C NT+AK+EK
PC 3001 VARIO
Pro
MZ 2C NT
MZ 4C NT
MD 1C VARIO
-SP
7
1.5
2
12
3
4
2.0
3.4
2.0
Process Requirements
Vacuum Drying Oven
Pump Requirements
• Mediumtohighvacuum• Optimumheattransfertothesample• Largeamountsofvapourproduced• Vacuumcontrolforshortprocesstimes&high reproducibility• Condensate&dropletseparationbetweenthepump&oven• Recoveryofresidualsolventvapoursafterthepump
• Excellentchemical&condensatecompatibility• Effectivegasballastsystemtopreventcondensationinthepump• Verygoodultimatevacuumevenwithgasballastoperationfor continuousevaporation• Lowultimatevacuumforhighboilingsolvents• Inletseparator&missioncondenserforsolventrecovery&to minimiseenvironmental/labairpollution• ATEXCat3approvalforvapourpathtopreventignitionof flammablesolvents
Our best selling Chemical Vacuum Pump for general use
-
-
-
-
- For larger/high volume ovens
For high boiling solvents at low temp (fully automatic with speed control, shorter process times)
MZ 2C NT+AK+EK
MD 4C NT+AK+EK
PC 3003 VARIO
MZ 2C NT
MD 4C NT
MV 2C NT
VARIO
7
1.5
0.6
12
3
2
2.0
3.4
2.8
Model CommentsBase
Pum
p
Ultim
ate
Vacu
um m
bar
(with
out g
as b
alla
st)
Chem
ical R
esist
ant
AK EK Man
ual C
ontro
l
VARI
O C
ontro
l
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Ultim
ate
Vacu
um m
bar
(with
gas
bal
last
)
Pum
ping
Spe
ed
(m3 /h
) 50
Hz
Chemistry Diaphragm Pumps are the most suitable (refer product recommendations below)
Chemistry Diaphragm Pumps are the most suitable (refer product recommendations below)
5
Toll Free: 0800 651 700 New Zealand www.jms.co.nz
Process Requirements
Gel Drying
Pump Requirements
• Mediumvacuum• Highflowratesduetoleakageacrossthegel• Vacuumregulationtopreventgeltearing• Condensate&dropletseparationbetweenthepump& geldryer
• Excellentchemical&condensatecompatibility• Effectivegasballastsystemtopreventcondensationinthepump• Highpumpingspeeds• Inletseparator&emissioncondenserforsolventrecovery• Vacuumregulationtopreventgeltearing
Our best selling Chemical Vacuum Pump for general use
--2 -MZ 2C NT +2AK
MZ 2C NT
7 12 2.0
-Based on popular MZ 2C NT pump & includes vacuum control plus manometer on the pump
PC 101 NT MZ 2C NT
7 12 2.0
Model CommentsBase
Pum
p
Ultim
ate
Vacu
um m
bar
(with
out g
as b
alla
st)
Chem
ical R
esist
ant
AK EK Man
ual C
ontro
l
VARI
O C
ontro
l
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Ultim
ate
Vacu
um m
bar
(with
gas
bal
last
)
Pum
ping
Spe
ed
(m3 /h
) 50
Hz
Chemistry Diaphragm Pumps are the most suitable (refer product recommendations below)
Process Requirements Pump Requirements
Perfect for single filtrations & small SPE manifolds - vacuum regulation is optional
-
-
-
-
--
-- -2
-
-
-
--
-- Higher pumping speeds for multiple filtrations
For Aqueous filtration only
Multiple filtrations with pump inlet/outlet protection against condensation
ME 1C
ME 1
• Mediumvacuum• Subjecttofiltersize&leakagerate,flowratecould beimportant• Speedoffiltrationispartlyinfluencedbyconsistencyof thefiltercake• Vacuumregulationisbeneficialtocontrolthefiltration /SPErate
• Singlestagediaphragmpumpwith70-100mbarultimate vacuumisideal• Excellentchemical&condensatecompatibilityforsolvent filtration/SPE• Vacuumregulationtodefineflow/driprateisideal• Forautomatedprocessesadigitalvacuumcontrol/program ispossible
ME 2C NT
ME 4C NT +2AK
-
-
-
ME 4C NT
100
100
70
70
-
-
-
-
0.7
0.7
2.1
3.9
Model CommentsBase
Pum
p
Ultim
ate
Vacu
um m
bar
(with
out g
as b
alla
st)
Chem
ical R
esist
ant
AK EK Man
ual C
ontro
l
VARI
O C
ontro
l
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Ultim
ate
Vacu
um m
bar
(with
gas
bal
last
)
Pum
ping
Spe
ed
(m3 /h
) 50
Hz
Diaphragm / Chemistry Diaphragm Pumps are the most suitable (refer product recommendations below)
Filtration & Solid Phase Extraction
6
Free Call: 1800 251 799 Australia www.johnmorris.com.au
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Local Vacuum Networks (VACUU-LAN)
Description
• VACUU•LANvacuumnetworksaremodular indesignallowingyoutotailoryourspecific needs&makeiteasytosupplyseveraldifferent applicationswith1vacuumpump (supplyingseveralapplications&workstations)
• Theyareextremelyversatileplussaveboth money&spacewheremanyusersareworking withvacuuminalaboratory(avoidsthedrawbacks ofacentral‘house’vacuumsupply)
• Forthevacuumoutletsatworkplacesvery versatilemodulesareobtainable (whichcanbeeasilyupgraded)
• Modulesareresistanttochemicals(built-in checkvalvesensureadjacentapplicationsdonot contaminateorinterferewithoneanother)
• Idealforneworexistinglaboratories
• Easilyupgradablewithquick&costeffective replacementofcomponents
For further information & options available, simply contact John Morris Scientific for professional assistance.
Base
Pum
p
Ulti
mat
e Va
cuum
mba
r (w
ithou
t gas
bal
last
)
Chem
ical
Res
istan
t
AK EK Man
ual C
ontr
ol
VARI
O C
ontr
ol
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Ulti
mat
e Va
cuum
mba
r (w
ith g
as b
alla
st)
Pum
ping
Spe
ed
(m3 /h
) 50
Hz
Model Comments
Adaptive, demand-driven pumping speed, 20% more flow, lowest energy demand
-
-
PC 3004 VARIO
PC 3016 NT VARIO
EK Peltronic
Fittings
MD 4C NT VARIO
ME 16C NT VARIO
A coolant-free emission condenser. All wetted parts are highly chemically resistant, the condenser is especially designed to be added to existing pumping units & allows the replacement of common condensers working with external coolant. The condenser is ideally suited for applications where cooling water is not available or desired.
Large selection of modular fittings for vacuum workstations & also for benchtops & fume hoods
1.5
70
3
100
4.6
19.3
Chemistry Diaphragm Pumps are the most suitable (refer product recommendations below)
7
Toll Free: 0800 651 700 New Zealand www.jms.co.nz
Perfect for small hybrid turbo <70L/sec-
-
-
-Higher pumping speeds for medium sized hybrid turbo pumps <500L/sec
Ideal for larger turbo pumps >500L/sec & vibration sensitive analytical equipment (SEMs)
MD 1
MD 4 NT
MV 10 NT VARIO
1.5
1
0.3
1.2
3.8
12.1
Most popular Freeze Drying/ Schlenk Line rotary vane pump, available with cold trap upgrade for Schlenk Lines
--
Unique Rotary Vane/Diaphragm combination pump for unrivalled chemical resistance (ideal for solvent freeze drying & Schlenk Lines)
RZ 6
RC 6 Hybrid
-
-
2 x 10-3
2 x 10-3
1 x 10-2
1 x 10-2
5.7
5.9
Base
Pum
pU
ltim
ate
Vacu
um m
bar
(with
out g
as b
alla
st)
Ulti
mat
e Va
cuum
mba
r (w
ithou
t gas
bal
last
)
Pum
ping
Spe
ed
(m3 /h
)50
Hz
Chem
ical
Res
istan
t
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Oil
Pum
p
VARI
O C
ontr
ol
Exha
ust F
ilter
Cont
rolle
r - C
VC 3
000
Ulti
mat
e Va
cuum
mba
r (w
ith g
as b
alla
st)
Pum
ping
Spe
ed
(m3 /h
) 50
Hz
Model
Model
Process Requirements
Process Requirements
Freeze Drying (Lyophilisation)
Turbo Backing
and Schlenk Line
Pump Requirements
Pump Requirements
Comments
Comments
• Highvacuum• Volumeflowrateappropriatetofreezedryer• Hightolerancetowatervapour• Vacuumregulationiscriticaltokeeptheproductfrozen• Continuous24/7operation• Chemicalresistanceifsolventistobefreezedried
• Roughingpumpvacuumlevelmustmeettheminimum backingpressuredemandsoftheturbopump• Turbomustbeprotectedduringpowerfailure• BackingPumpneedstobeabletostartundervacuum• Lowvibrationforanalyticalequipment(SEMs)
• Ultimatevacuumto10-3mbar• Highflowrateatlowvacuumlevels• Highvacuumpressureswithgasballastopenformaximumwater vapourtolerance• Continuousdutycycleratedwiththermalcut-outprotectionon themotor• ChemistryHybridRC6pumpisrecommendedforsolvent vapourdrying
• Ultimatevacuumdownto1mbarisgenerallysufficientfor modernturbohybridpumps• Highpumpingspeedatlowvacuumlevelsduetouniqueplanar diaphragmdesign• Diaphragmpumpshaveintegratedanti-suckbackvalvesto preventventingunderpowerfailure• Reliablestartingundervacuum• VARIOpumpsofferzerovibration&lowultimatevacuumdueto uniquevariablespeeddriveturbobackingmode
Rotary Vane Vacuum Pumps or Chemistry Hybrid Pumps are the most suitable (refer product recommendations below)
Rotary Vane Vacuum Pumps or Chemistry Hybrid Pumps are the most suitable (refer product recommendations below)
8
Free Call: 1800 251 799 Australia www.johnmorris.com.au
Ideal for labs with house central vacuum
--
-
--
-
- - -
-
--
With integrated ME 1C Vacuum pump - quiet & vibration free
Advanced system with integrated vacuum pump & non-contact liquid level sensor
BVC Basic
BVC Control
BVC Professional
ME 1C
ME 1C
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Custom Designed Solutions
Accessories
Repairs & Maintenance
John Morris Scientific is also able to customer design configurations, with complete installation capabilities, to meet your individual requirements - satisfying the highest technical, economic & environmental standards.
John Morris Scientific also has an extensive range of Vacuubrand accessories & spare parts.
Our Instrument Services Division provides a choice of Service Agreements to suit your needs & performs routine maintenance & repairs on all Vacuubrand vacuum equipment to ensure it is operating to its optimum capacity.
We also offer calibration of vacuum gauges in our own calibration laboratory (with DAkkS accreditation).
Base
Pum
p
4L P
P Co
llecti
on F
lask
Prot
ectio
n Fi
lter (
0.2
µm)
Mec
hani
cal P
ress
ure
Switc
h
Touc
h Pa
nel
Adju
stab
le S
uctio
n Po
wer
Non
-Con
tact
Liq
uid
Le
vel S
enso
r
Auto
mati
c O
n/O
ff Sw
itch
Self-
Clos
ing
Qui
ck
Coup
lings
Vacu
u Ha
nd C
ontr
ol
VHC
Pro
2L B
oros
ilica
te G
lass
Bo
ttle
Rack
Model
Process Requirements
Liquid Aspiration
Pump Requirements
Comments
• Mediumvacuum• Adjustablevacuumsource• Delicateaspirationofsensitivesamples-rapidaspirationof largesamplevolumes• Minimaldistractionofvacuumcontrolwhilehandling biologicalmaterials
• Singlestagediaphragmpumpwithgoodsuctionpower• Excellentchemicalcompatibilityforsolventsample&disinfecting• Vacuumregulationtodefinetheaspirationflowrate• Collectionflaskwithsterilefiltertoprotectthepump& workplacefrombiologicalhazards
Liquid Aspiration Systems are the most suitable (refer product recommendations below)
9
Toll Free: 0800 651 700 New Zealand www.jms.co.nz
Overview of Pump Types
Chemistry Diaphragm Pumps
100%oil-free&freeofabrasion,quiet&requirelittleservice Typicalapplicationsincludeevacuatingchemicallyaggressivegases&vapours (egrotaryevaporators,vacuumdryingcabinets¢rifugalconcentrators) 2,3&4-stagepumpsalsohaveagasballastvalve Hermeticallyseparatedpumpingchambersfromthedrivesystem Eliminatecostofwater&itscontamination PC 3001
VARIO Pro
MV 10 NT VARIO
HB 40 B2
Diaphragm Pumps
100%oil-free&freeofabrasion,quiet&requirelittleservice Hermeticallysealeddrivespacefromthepumpingchamber(protects mechanicalpartsfromcorrosionwhichextendsoperatinglife) Highperformancepumps(highpumpingchambervolumerelativeto theminimaldeadspace)
Rotary Vane Vacuum Pumps
Up to 10-3 mbar Innovativelubricationsystemincludesabuilt-inoilpump(withlargeoilvolume) Highvapourpumpingcapabilityforwater&solvents Protectionagainstventing&oilbackflow(asaggregateisvacuum-sealedafter switch-off)
Chemistry Hybrid Pumps
RC6ChemistryHybridpumpisacombinationofa2-stagerotaryvanepump &a2-stagechemistrydiaphragmpumpforoptimisedcorrosionresistance Highersolventvapourpumpingcapability&resistancetoaggressivegases thanconventionalrotaryvanepumps Thepumpingunitversion(PC8withRC6)hasexcellentenvironmental friendlinessduetoefficientsolventrecovery
High-Vacuum Pumping Units
Up to 10-6 mbar High-performance & reliable Compriseair-cooleddiffusionpump,2-stagerotaryvanepump(asabacking pump)&allconnectingparts(includinghigh-vacuumvalve,ventilationvalve &abypassline)
RC 6 Hybrid
RZ 2.5 +FO + VS16
10
Free Call: 1800 251 799 Australia www.johnmorris.com.au
-
1,000 to 0.1
- -
-
Optional Optional Optional Optional
1,000 to 1 x 10-3
1,100 to 1
1,000 to 1 x 10-3
1,000 to 0.1
-
-
-
-
-
-
-
-
CVC 3000 Detect
(bench top)
CVC 3000
VNC 2
CVC 3000 + VSP 3000, KF
DN 16 (pump not included)
CVC 3000 + VSP 3000, KF DN 25 (pump not included)
- -
- - -
- 1
- -- 5 x 10-9
-1 x 10-3
0.1
1
-
-
--
- -
--
-
-
--
-
DVR 3
DVR 2
DCP 3000+ VSK 3000
DCP 3000+ VSP 3000
DCP 3000+ MPT 100
Scientific
JohnMorris John Morris Scientific
Service plus Solutions
Batte
ry P
ower
ed
ATEX
- Ca
tego
ry 2
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Chem
ical
Res
istan
t
Low
er M
easu
ring
Lim
it (m
bar)
Mea
surin
g Pr
inci
ple
Diap
hrag
m (C
apac
itive
)
Mea
surin
g Pr
inci
ple
Heat
Co
nduc
tion
(Pira
ni)
Mea
surin
g Pr
inci
ple
Cold
Ca
thod
e
Mea
sure
men
t Gas
Typ
e In
depe
nden
t
Model
Vacuum Gauges
Mea
surin
g Pr
inci
ple
Cold
Ca
thod
e
ATEX
- Ca
tego
ry 3
(in
tern
al A
tm o
nly)
Chem
ical
Res
istan
t
Cont
rol R
ange
(mba
r)
Mea
surin
g Pr
inci
ple
Diap
hrag
m (C
apac
itive
)
Mea
surin
g Pr
inci
ple
Heat
Co
nduc
tion
(Pira
ni)
Mea
sure
men
t Gas
Typ
e In
depe
nden
t
Model
Vacuum Controllers
Vacuum Gauges & Controllers
To ensure you select the right vacuum system for your needs or for servicing your equipment, simply contact John Morris Scientific for professional assistance.
11
Toll Free: 0800 651 700 New Zealand www.jms.co.nz
Benefits of Vacuubrand Diaphragm Pumps
PC 3001 VARIO Pro
German manufactured, Vacuubrand pumps are regarded as the most reliable chemistry diaphragm pumps on the market plus offer an extensive product range.
This diaphragm assembly cut-away highlights Vacuubrand’s unique metal stability core design. All media contacted parts within the chemistry diaphragm pump range are manufactured from Fluro polymers and perfluro elastomers for exceptional chemical resistance of aggressive solvents & acids.
No other diaphragm pump offers the same stability, reliability or long-term vacuum performance within harsh chemical environments - with the VARIO pumps offering up to 40,000 hours (close to 5 years) diaphragm lifetime.
As the benchmark for chemistry vacuum pumps & our most popular vacuum pump for rotary evaporation, the PC 3000 VARIO Pro offers:
No Programming Required: The CVC3000 with VARIO control automatically optimises the vacuum throughout the evaporation process for unattended operation, high process reproducibility & shorter process times, even for large amounts of vapour Easy Evaporation of High Boiling Solvents: Low 2 mbar ultimate vacuum (4 mbar with
gas ballast) enables reliable evaporation of high boiling point solvents (DMF, DMSO) even with low rotary evaporator bath temperatures Exceptional Service Lifetime: VARIO technology means the pump runs as fast as
the process requires (often the motor switches off) - extending service intervals with the diaphragm lifetime of up to 40,000 hours (up to 5 years) continuous use, minimises energy consumption & reduces noise levels
Competitor unit in auto mode - only detects & holds at first boiling point (& evaporation stops as vacuum does not adapt to additional boiling points)
VARIO control detects each boiling point & continuously adapts to optimise vacuum conditions plus:• Avoids sample loss by eliminating bumping & foaming• Waste vapour recovery rates near 100% keeps lab air clean
PC 3001 VARIO Pro at a working pressure of 20 mbar provides:• ≈50%moresuctionthancompetitor1• ≈100%morepumpingspeedthancompetitor2
VARIOprovidessignificantlybetterultimatevacuumwithopen gasballast(continuouspurge)valve:• Competitor1offersnogasballast(purge)valve• Competitor2can’treach20mbarwithanopengasballastvalve
Benefits of PC 3001 VARIO Pro v’s Competition
Fully Automatic Processing Up to 100% More Pumping Speed
Metal Stability Core
For Over 50 YearsFor Over 50 Years
Scientific
JohnMorris John Morris Scientific
Service plus SolutionsAustraliaAddress 61-63 Victoria Avenue Chatswood NSW 2067 AustraliaFree Call 1800 251 799Enquiries +61 (0) 2 9496 4200 Email [email protected] www.johnmorris.com.au
At John Morris Scientific we offer more than just the product - we provide the full package -
sales and servicing of instrumentation plus design tailored solutions to meet your needs.
We offer more than 'just the box'
SupportSalesSolutions Service
New ZealandAddress 78 Wellesley Street Auckland NZ 1010Toll Free 0800 651 700Enquiries +64 (0) 9 366 3999 Email [email protected] www.jms.co.nz
Top Related