Ustroń 10-12.09.2012Design monitoring systems based on XBMS
Presents: M.Sc. Adam Jakubowski
Web-basedOpen Building Management System
Reasons to design monitoring based on XBMS:
The comprehensive (includes the widest range of subsystems).
An easy way to design different types of monitoring systems.
Fully web-based and real-time system.
Supports a wide range of open communication standards.
Possibility of integration various manufacturers devices.
Full support for XBMS development (specialized appliactions & drivers)
Support for users & groups rights for access to the system.
Multimedia visualization interfaces in Adobe Flash technology.
Easier and faster installation and commissioning BMS.
Easier and cheaper diagnostics and service management system.
Technical support services and maintenance of the system.
Safe-class UNIX operating system.
BuildingManagementSystem
SecurityManagementSystem
ConferenceRoomSystems
XBMS
Lighting Power Solar power plants Photovoltaic power plants Substations Water technology HVAC Measurements of media
consumption VoIP doorphones
Fire alarm centrals Early smoke detectors Intruder detection systems Access control systems
Adjustable lighting Blinds & screens Audio/Video matrix Projectors Sound
Comprehensive integration concept
The estimated size of building
(BMS points or m2)
BMS
building
installations
SMS
security systems
CRS
Conference rooms
Typical
equipment
DELL servers
512 – 1000 do 300 m2 NEURON BOX ASTRO BOX CRS BOX ADVANTECH UNO
1000 – 4000 do 2000 m2 NEURON BMS Server ASTRO SMS Server CRS Server DELL R210
4000 – 10000 do 10000 m2 NEURON BMS Server ASTRO SMS Server CRS Server DELL R210
10000 – 20000 do 40000 m2 NEURON BMS Server ASTRO SMS Server CRS ServerDELL R410
20000 – 50000 pow.40000 m2 NEURON BMS Server ASTRO SMS Server CRS ServerDELL R510
XBMS servers family:
Client-Server Technology (client presents the data received from the server)
Access to the system only by web browsers based on individual privilages
Multimedia user interface in Adobe Flash
Presentation of the event and the physical values in real-time
Support user rights to visualization scenes and objects in the scene
VDL - library of ready to use visualization objects
Web-based user interface:
SIP (VoIP) OPC SNMP DMXSIP (VoIP) OPC SNMP DMX
Online real-time information system, which supports open communication standards
Supported open network protocols
Full support for XBMS project development (device and network drivers and others with their own documented protocol).
The ability to create specialized applications, based on the data stored in the SQL database
Technical support services and maintenance of the system
Customizable universal signal boxes:
Universal signal box’es as XBMS supplement
to monitor digital and analog signals
monitoring and control systems (eg solar power plants)
Reason to design universal signal box’es
The designer does not need to know the automation details.
Defines only the number of signals and their type, selected sensors.
Digital and analog signals should be reduced to a switchboard
Subsequently the signals is sufficient to bring to an Ethernet network.
Block diagram of the BMS becomes simpler.
For more complex functions sufficient to describe the algorithm
Examples of typical XBMS installations:
Central BMS, SMS and CRS in objects of different types (office buildings, hotels, apartment buildings, shopping centers, etc.)
Data Processing Centres (known as server rooms)
Automation of an apartment or hotel room
Water Parks or Aquaparks
Hospitals (metering media)
Global Monitoring for distributed objects
Monitoring Specialist (eg linear temperature measurement)
Museums and monuments
Conference rooms
The monitoring system in the data center :
Precision cooling Emergency Power System Power analyzers Measurements of temperature
and humidity UPS Fire Alarm System Early warning smoke detectors Intruder Alarm System Access Control System VoIP doorphones
Apartment or hotel room automation:
HVAC Reed doors and windows Multiroom zone Heating Measurement of temperature
and humidity. Touch panels Biometric access control. LED Lighting Sunblinds
Water Park Monitoring System:
Ventilation Water Technology The heating substation Lighting Photovoltaic Power Plant Solar Power Plant
Monitoring system in hospital:
Ventilation Glycol energy measurement Electricity consumption. Technical steam consumption Water consumption Gas consumption Photovoltaic Power Plant Solar Power Plant
Example of SMS system:
Intruder Detection System Fire Detection System Early warning smoke detect. Automatic extinguish Gas detection system Personnel Identity Audible Warning System
Example CRS system:
Sunblinds Lighting Projector Audio/Video Matrix Sound Portable Tablet PC CD / DVD Screens
Data Center of PGNiG S.A. (Polish Oil and Gas Company) BMS in Customs House in Warsaw Data Center in KGHM S.A. (Polish Copper & Silver producer) BMS in CHP „Kraków” S.A. (Heat and Power Plant in Krakow) Data Center EUROBANK S.A. Data Center Kredyt Bank S.A. Date Center DB Shenker Transportation & Logistics BMS of Apartament, Mokotowska 59 in Warsaw BMS in Polish Academy of Science Branch in Katowice Technical University In Warsaw Automation Lab Technical University In Lodz BMS in Water Park in Elk BMS in Water Park in Olsztyn SMS in Palmiry Museum (Warsaw) Linear temperature measurement in Polaniec Power Plant
Selected projects in Poland:
Top Related