ForReferenceofNECA2016BostonAttendeesOnly 1
October10,2016
Enhance System Models With Real Electrical Components
Enhance System Models With Real Electrical Components
Judy MillerSysQue
This session is eligible for 1 Contact Hour.
For these hours to appear on your certificate, you must:– Have your badge scanned at the door– Attend 90% of this presentation– Fill out the online evaluation for this session
ForReferenceofNECA2016BostonAttendeesOnly 2
October10,2016
Design to Construction Revit MEP
• Real Content - Example: Electrical
Design to Construction Revit MEP
• Real Content - Example: Electrical
ForReferenceofNECA2016BostonAttendeesOnly 3
October10,2016
Design to Construction Revit MEP
• Real Content - Example: Electrical
Design to Construction Revit MEP
• Real Content - Example: Electrical
ForReferenceofNECA2016BostonAttendeesOnly 4
October10,2016
Design to Construction Revit MEP
Design to Construction Revit MEP
• Real Content - Example: Electrical
ForReferenceofNECA2016BostonAttendeesOnly 5
October10,2016
SysQue Electrical• SysQue Electrical adds LOD
300-400 real world content to electrical BIM coordination with 3D Revit families
• Revit families based on manufacturers’ bent conduit tube, basket, cable tray, busway and rack.
• Manufacturers, such as B-Line and Allied, provide Revit BIM with accurate PDF specifications sheets, including dimensions and installation methods.
Design to Construction Revit MEP
• Real Content - Example: Electrical
ForReferenceofNECA2016BostonAttendeesOnly 6
October10,2016
Converting Generic Conduit• Select the SysQue system to convert
the conduit to (material, panel/circuit, or wirefill)
• If you want to specify the Service Type and color, edit the straight length of conduit icon by right clicking and select edit
• Select all like sizes of generic conduit to be converted
• If you don’t want cut lengths and couplings to be placed during the conversion, click on “Process Fittings”
• Select “Change System”
Converting Generic Conduit• Select the SysQue system to
convert the conduit to (material, panel/circuit, or wirefill)
• If you want to specify the Service Type and color, edit the straight length of conduit icon by right clicking and select edit
• Select all like sizes of generic conduit to be converted
• If you don’t want cut lengths and couplings to be placed during the conversion, click on “Process Fittings”
• Select “Change System”
ForReferenceofNECA2016BostonAttendeesOnly 7
October10,2016
Converting Generic Cable Tray• Select the SysQue system to
convert the cable tray to• If you don’t want cut lengths
and couplings to be placed during the conversion, click on “Process Fittings”
Converting Generic Conduit• If you want to specify the
Service Type and color, edit the straight length of cable tray icon by right clicking and select edit
• Select all like heights of generic tray to be converted
• Select “Change System”
ForReferenceofNECA2016BostonAttendeesOnly 8
October10,2016
Common Steps for Converting Content
Select “Change System”
Step3
Select generic content
Step2
Select SysQue System
Step1
Supports for ElectricalSysQueSupportsautomaticallypopulatesyourPipes,Ducts,CableTrays,Conduitsaccordingtothehangerparts,hardware,andspecsyoudefine,andletsyoucreatedetailedhangermapsandprefabdrawings.
Top Related