Toshiba V-Series
Toshiba International Corporation
Control System Requirements
Flexibility Scalability Open Architecture
Networks Engineering Environment
Connectivity Security Serviceability / Maintainability Integrated Solution
Flexibility / Scalability
Flexibility:• The ability of a platform to implement the
control requirements across the Plant. Scalability:
• The ability of a common platform to be scaled to suit the control requirements.
Flexibility
Information
Computer
I/O
HMI
Conventional System
Electrical
PLC
Tool
HMI
Direct I/O
Instrumentation
DCS
Tool
HMI
Process I/O
Tc-net (SCAN Transmission)
FA3100TOSHIBAPOWER
TOSHIBA
Ethernet
HMI
Ethernet
Internet
V series-based System
Field NetworkProcess I/O
S L C Network
Fieldnet
Network
Direct I/O
Tool
Station Bus
V Series vs Conventional Platform
BusinessPC
One-LoopController
IndustrialPC
PLC
Scale
Large
Small
Mini
DCS
S: Sequence Control
Motion, Logic
L: Loop Control
LoopC: Computer Control
Data processingPurpose
V series
Flexibility – I/O Style
VVV
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
~PS
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
~PS
IF
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DirectI/O bus
IF
Direct I/O
Serial Bus(Duplex)
Process I/O
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
~PS
IF
DirectI/O bus
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
~PS
IF
DI335
123456789101112
123456789101112
123456789101112
123456789101112
DI335
123456789101112
123456789101112
123456789101112
123456789101112
Direct I/O
Serial Bus(Duplex)
Process I/O
EthernetTC-net
Direct I/O & or
Process I/O
Direct I/O for discrete application. Process I/O for analog loops and
redundancy. Ease of access to each I/O from S and L.
Scalability
Integrated Controller
V series
Scalability
S: Sequence Control
L: Loop Control
C: Computer Control
S3 L3 C3
S2 L2 C2
L1
Model 3000 series
Model 1000 series
Scale
Large
Small
Mini
Purpose
Model 2000 series
Open Architecture
Networks– Ethernet – TCP/IP, UDP/IP– DeviceNet– FieldBus
Engineering Environment– IEC61131-3
Interfacing– OPC
Open Architecture - Networks
TC-net
DeviceNetModel3000
Model 1000
Touch Panel
Ethernet
PC • Monitoring & Control Network: Ethernet
Foundation Fieldbus
Model 2000
• High-speed Control Network: TC-net
Open Architecture - Networks• Ethernet Supervising and Information LAN
(Duplicated Transmission Optional)
• TC-net 100 Time Critical Application
Metal Industries, General purpose, etc.
• TC-net 10 PLC/PLC Communication
System and Control Global Variable
• FL-Net Remote I/O High Speed Network
• ProfiBus European Based Field Bus
• DeviceNet FA Device Open Network
• FieldBus Foundation Field Bus
• TL-S20 PLC/PLC Communication, TOSHIBA Drive
• ControlNet AB Data LAN
•OPC OLE for Process Control
Eng
inee
ring
Env
iron
men
tIEC61131-3 Summary
5 languages– Select and combine any of them
User definable function block– Software components, reusability
Integrated Engineering environment– No boundary between PA & FA
Layered Engineering User definable data type Strict data type & syntax check Common language and terminology for
application engineers worldwide
Engineering EnvironmentIntegrated Engineering Tool
Engineering Environment
C2PU63
V
PS692
Ethernet
Engineering &
MaintenanceServer on C2
DI635
DO635
S2PU72
V
PS692 DI635
DO635
EN631
DI635
DO635
VWireless
LANTransmitt
er
ISP
ISP
ISP
In-houseTool
Client
MobileTool Client
RemoteTool
ClientCli
ent
& S
erve
r b
ased
En
gin
eeri
ng
tool
Ease of Engineering Data Management– One set of Engineering data stored in one place, ready for on-line maintenance anytime– Prevents confusion over engineering data management– Industrial PC based platform for 24 hours/365 days operation with reliability
Team Engineering & Remote Access– Enables team engineers working on the engineering data concurrently– Remote access through internet/intranet
Connectivity
Internet
Internet Access Line
WAPGateway
MobilePhone
WAPGateway
MobileTerminal
ISP
PC at Central Control Station
Bringing together of mobile technology with the control system Efficient and secured remote monitoring by image transmission on site
S2&C2
Inte
grat
ed S
olut
ions
Pre-configured Faceplate & 8 Loop Keyboard
Multi-loop manual operation Flexible layout of faceplates for commissioning Just configure tag grouping, no need to prepare graphic picture
Inte
grat
ed S
olut
ions
COGEN System
S module
L module
C module
HRSGGas Turbine
V-SeriesController
OIS-DS1 OIS-DS2
EWS-Printer
EWS
V 2000Primary
V 2000Secondary
Process I/O
V 2000Primary
V 2000Secondary
Process I/O
V 2000Primary
V 2000Secondary
Process I/O
V 2000Primary
V 2000Secondary
Process I/O
OIS-DS3
Hard CopyAlarm Prt
Unit #1 Unit #2 Unit #3 Unit #4
Functional System Layout
Inte
grat
ed S
olut
ions
• High-speed linkage between C2 and S2.• Data sharing, with easy connection to HMI.• Sophisticated operation and advanced control.
C2 with Windows NT
S2
Data link through station bus
Machinery control via Direct I/O
Machine Control Application
Panel Display
Inte
grat
ed S
olut
ions
Compact Solutions - L1
SCADAPackage
Compact SCADA
Graphic Panel
Hybrid Controller with Graphic Panel
Loop Display
Loop Controller
Integrated Engineering Tool
Integrated Controller V series
Variable Variable
Variable
DCS: Loop Control
PLC: Sequence Control
Computer: New Mode of Control
Top Related