Zeshan Aqeel Senior Application ScientistZeshan loves to collect watches and the Back to the Future Trilogy. He has twin boys who drive him crazy! He is an Apple Fanboy for life and he likes being in the lab more than anywhere else.
TN-7002
Page 1 of 4
APPLICATIONS
Having trouble reproducing this method? We would love to help! Visit www.phenomenex.com/LiveChat to get in touch with one of our Technical Specialists
How to Install a Claricep™ Flash Column onto an ISCO CombiFlash® Rf InstrumentZeshan Aqeel and Rola El abaji Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA
IntroductionClaricep columns are compatable with the ISCO CombiFlash Rf instrument and installing them is easily done using this step by step procedure.
When you first install a Claricep Flash Column on a CombiFlash Rf instrument, the following notification will appear on the instru-ment screen: “Unable to Identify RediSep Rf Column”. This simply means that the system does not recognize the flash column and you need to program your CombiFlash Rf instrument for use with the Claricep flash column.
If you are using Claricep Screw-on i-series or s-series column, you will need a stopcock (AH0-6049) to aid with installation.
Step 1: Install Flash ColumnInstall a Claricep Flash Column on the CombiFlash Rf instrument.
1
2
3
Step 2: Press “MANUAL SELECT”As you lower the inlet port-valve to the top of the column, an on-screen message will appear matching either Figure 1 or Figure 2. In either case, you will then click on the “MANUAL SELECT” button to take you to the settings menu.
Claricep™ Flash Columns
Figure 2
Figure 1
TN-7002
Page 2 of 4
Step 4: Select Column SizeOnce you have chosen the type of material, you need to designate the gram size of the column. Just go back to the “REDISEP” tab (Figure 5) and find the gram level that is most similar to the size of the Claricep™ column you want to install.
For example, the CombiFlash® Rf has preset gram sizes of 4, 12, 24, 40, 80, 120, 220 and 330 grams, so for a 20 g Claricep col-umn you would select 24 g as the appropriate setting. Note: please refer to Table 1 for a comparison of corresponding Claricep and RediSep® column sizes.
Step 3: Select Media TypeAt the bottom screen select the menu toggle labeled “REDISEP” (Figure 3).
Choose the last option, “SELECT MEDIA” and then select the type of material you will be using (for example: Silica, C18, Amine, etc.) Figure 4.
Figure 3
Figure 4
Figure 5
Table 1
Claricep Packing Amount
(g)
Corresponding RediSep Preset
(g)
RecommendedFlow Rate
(mL)
4 4 18
12 12 30
20 24 35
40 40 40
80 80 60
120 120 85
220 220 150
330 330 200
Step 5: Select the desired “EQUILIBRATION” and “FLOW RATE” as you would normally do. Different columns will have varying flow rates depending on the size, so enter the appropriate flow rate from Table 1.
Step 6: Find “RUN LENGTH” from the chart on the right of the screen.
Step 7:Select the desired “RUN LENGTH”.
ConclusionIt is easy to install a Claricep column on a CombiFlash Rf system by simply programming the instrument. Once you have set up your method, be sure to save it in the instrument. The next time you run the method, simply go to the saved method and enjoy all the benefits and COST SAVINGS you get from using the Claricep flash columns.
TN-7002
Page 3 of 4Having trouble reproducing this method? We would love to help! Visit www.phenomenex.com/LiveChat to get in touch with one of our Technical Specialists
Spherical Bonded Phase; Average Particle Size: 20-35 μm; Pore Size: 100 Å
TYPE Claricep Part No. Silica Amount (g) Quantity (pk)
C18
SO230004-0 4 20
SO230012-0 12 20
SO230020-0 20 20
SO230040-0 40 10
SO230080-0 80 5
SO230120-0 120 5
SO230330-0 330 1
Also available in i-series, s-series & c-series (12 g, 20 g, 40 g, 80 g, & 120 g) per request (Contact your Sales Rep)
Spherical Bonded Phase; Average Particle Size: 20-35 μm; Pore Size: 100 Å
TYPE Claricep Part No. Silica Amount (g) Quantity (pk)
AQ C18
SQ230004-0 4 20
SQ230012-0 12 20
SQ230020-0 20 20
SQ230040-0 40 10
SQ230080-0 80 5
SQ230120-0 120 5
SQ230330-0 330 1
Also available in i-series, s-series & c-series (12 g, 20 g, 40 g, 80 g, & 120 g) per request (Contact your Sales Rep)
Irregular Silica; Average Particle Size: 40-60 μm; Average Pore Size: 60 Å
TYPE Claricep Part No. Silica Amount (g) Quantity (pk)
Silica (CS) Standard Silica
CS140004-0 4 20
CS140012-0 12 20
CS140020-0 20 20
CS140040-0 40 10
CS140080-0 80 5
CS140120-0 120 5
CS140330-0 330 1
CS140800-0 800 1
CS1401500-0 1500 1
Also available in i-series, s-series & c-series (12 g, 20 g, 40 g, 80 g, & 120 g) per request (Contact your Sales Rep)
Spherical Silica; Average Particle Size: 20-35 μm; Pore Size: 60 Å
TYPE Claricep Part No. Silica Amount (g) Quantity (pk)
Spherical Silica
SS130004-0 4 20
SS130012-0 12 20
SS130020-0 20 20
SS130040-0 40 10
SS130080-0 80 5
SS130120-0 120 5
SS130330-0 330 1
Also available in i-series, s-series & c-series (12 g, 20 g, 40 g, 80 g, & 120 g) per request (Contact your Sales Rep)
Spherical Bonded Phase; Average Particle Size: 40-60 μm; Pore Size: 100 Å
TYPE Claricep Part No. Silica Amount (g) Quantity (pk)
C18
SO240004-0 4 20
SO240012-0 12 20
SO240020-0 20 20
SO240040-0 40 10
SO240080-0 80 5
SO240120-0 120 5
SO240330-0 330 1
SO240800-0 800 1
SO2401500-0 1500 1
Also available in i-series, s-series & c-series (12 g, 20 g, 40 g, 80 g, & 120 g) per request (Contact your Sales Rep)
Ordering InformationClaricep™
Your happiness is our mission. Take45 days to try our products. If you are not happy, we’ll make it right.
guarantee
www.phenomenex.com/behappy
TN-7002
Page 4 of 4
APPLICATIONS
TN64
4810
18_W
Terms and Conditions Subject to Phenomenex Standard Terms and Conditions which may be viewed at www.phenomenex.com/TermsAndConditions Trademarks Claricep is a trademark of Tianjin Bonna-Agela Technologies Co. Ltd. CombiFlash® Rf Systems and RediSep® are registered trademarks of Teledyne Instruments, Inc. DBA Teledyne ISCO, and are used only to identify for purposes of compatibility.Disclaimer Phenomenex is in no way affiliated with Teledyne Instruments, Inc. FOR RESEARCH USE ONLY. Not for use in clinical diagnostic procedures. © 2018 Phenomenex, Inc. All rights reserved.
Australiat: +61 (0)2-9428-6444
Austriat: +43 (0)1-319-1301
Belgiumt: +32 (0)2 503 4015 (French)t: +32 (0)2 511 8666 (Dutch)
Canadat: +1 (800) 543-3681
Chinat: +86 400-606-8099
Denmarkt: +45 4824 8048
Finlandt: +358 (0)9 4789 0063
Francet: +33 (0)1 30 09 21 10
Germanyt: +49 (0)6021-58830-0
Indiat: +91 (0)40-3012 2400
Irelandt: +353 (0)1 247 5405
Italyt: +39 051 6327511
Luxembourgt: +31 (0)30-2418700
Mexicot: 01-800-844-5226
The Netherlandst: +31 (0)30-2418700
New Zealandt: +64 (0)9-4780951
Norwayt: +47 810 02 005
Portugalt: +351 221 450 488
Singaporet: +65 800-852-3944
Spaint: +34 91-413-8613
Swedent: +46 (0)8 611 6950
Switzerlandt: +41 61 692 20 20
United Kingdomt: +44 (0)1625-501367
USAt: +1 (310) 212-0555
All other countries Corporate Office USA
t: +1 (310) 212-0555 [email protected]
www.phenomenex.comPhenomenex products are available worldwide. For the distributor in your country, contact Phenomenex USA, International Department at [email protected]
Top Related