THERMOTEK™ SELF ADHESIVE MEMBRANE OVER METAL SYSTEM DESCRIPTION
SELF ADHESIVE SYSTEM METAL (10 YR) AP-SABS-SACS
SYSTEM COMPONENTS AND WEIGHTS
Note: Detail system information in file SELF ADHESIVE SYSTEM METAL (10 YR) AP-SABS-SACS (attached USB.)
No ProductCoverage
(100 sq. ft.)
1 ASPHALT PRIMER 1 gallon
2THERMOTEK SELF ADHESIVE 1.5 FV
SMOOTH180 sq ft
3THERMOTEK SELF ADHESIVE 3.0 FP
GRANULE89 sq ft
THERMOTEK DURAMASTIC Variable
THERMOTEK SELF ADHESIVE 1.5 FV
SMOOTHVariable
SILVER + GOLD + PLATINUM + SILVER + GOLD + PLATINUM +
1 THERMOTEK COATING 1 gallons 6.24 LB/SQ 7.25 LB/SQ 7.67 LB/SQ 6.86 Mils 8.06 Mils 8.2 Mils
2 THERMOTEK COATING 1 gallons 6.24 LB/SQ 7.25 LB/SQ 7.67 LB/SQ 6.86 Mils 8.06 Mils 8.2 Mils
+ 12.48 LB/SQ + 14.5 LB/SQ + 15.34 LB/SQ +13.72 Mils +16.12 Mils +16.4 Mils
+ 0 years + 1 years + 2 years + 0 years + 1 years + 2 years
10 years 10 years
OPTIONAL
TITLE 24
ADD TO SYSTEM
ADDITIONAL WARRANTY ( + YEARS )
40.5 LB/SQ
183.36 Mils
118.11 Mils
59.05 Mils
Dry Weight Lb Dry Mils
Warranty
SYSTEM
3.23 LB/SQ 6.2 Mils
SYSTEM
CRITICAL
POINTS
84.55 LB/SQ
128.28 LB/SQ
Variable Variable
Variable Variable
0. SUBSTRATE
1. ASPHALT PRIMER
2. THERMOTEK™ SELF ADHESIVE 1.5 FV SMOOTH
3. THERMOTEK™ SELF ADHESIVE 3.0 FP GRANULE
0
3
1
2
2
1 800 542 2334 | [email protected] | www.thermotekgroup.com V21310-VI1410
META
L
PART 1 – GENERAL
1.1 GENERAL
This document provides specifications for the application of product to roofing surface. This specification should be used only as a
general guide, with the addition of specific details as different job conditions warrant.
These tools include roofing products, coverage rate , installation procedures with THERMOTEK™ Roofing Products and complementary
products. Final determination of the fitness of the application of any THERMOTEK™ product shall not be made by anyone other than an
authorized representative of THERMOTEK™ Roofing Products.
1.1 APPLICABLE PUBLICATIONS: The publications listed below form a part of this specification to the extent referenced. The publications
are referred to in the text by the basic designation only.
A. American Society for Testing and Materials Publication (ASTM)
B. Underwriters Laboratories Inc. (U.L.)
C. CRRC – Cool Roof Rating Council
D. California Building Standards Code - Title 24
E. THERMOTEK™ Details, Drawings and Notes
1.2 QUALITY CONTROL
A. Warranty: The contractor shall warrant 5 years, from the date of completion of the work by waterproof system is free
from defects in materials and workmanship, all work repairs during this period must be performed by the contractor.
Any additional warranty must be provided by the contractor to the owner.
B. The manufacturer shall certify that the materials submitted have been used in like application and that they have
been actively engaged in the manufacture of these materials for a minimum period of 10 to 13 years prior to
Submittals, as required. The manufacturer shall certify that the contractor is authorized and approved for the
Application of their materials.
C. Applicator Qualifications
1) The applicator shall have general knowledge and general understanding of roofing as well as all
THERMOTEK™ Roofing products for any given specified project.
2) For all warranties, a firm, which has complete business stability, shall perform the work in this section, present
a copy of certification upon request by the Architect or the owner.
3) The installer, owner or Architect must review all the documents related all critical points and check list.
4) For different roofing details the installer, owner or Architect must contact a THERMOTEK™ roofing
representative for details, terms and conditions for warranty, All issues concerning the roof must be resolved
by written way.
1.3 SUBMITTALS
A. In the normal course of bidding, descriptive literature, technical data, and wet or dry samples of all materials
proposed for use under this specification shall be submitted upon request.
1.4 JOB CONDITIONS
A. To proceed with proper conditions, the applicator must be aware of the following:
1) UV curing time for all products is critical. The applicator must allow for sufficient cure time for each product.
Please be aware that outside temperatures will be a factor.
2) Do not begin work if rain or heavy dew is expected within twenty-four to forty-eight (24-48) hours of
application.
3) Do not begin work if temperatures are expected to fall below 50 degrees Fahrenheit and over 104 degrees
Fahrenheit during the duration of the job.
4) Other environmental conditions such as humidity, mist, dew, extreme temperatures, and condensation can
affect products in an inconsistent way.
1.5 PRODUCT STORAGE AND HANDLING
A. All products should be stored in a warm, dry, clean, well-ventilated area. Store above 40 degrees Fahrenheit at all
times.
1.6 PROTECTION OF PROPERTY:
A. Contractor shall take proper precautions to protect owners property against damage and overspray. The use of shield
boards, maskings and protective coverings shall be used as necessary. THERMOTEK™ is not responsible for damages
caused by the overspray of any of its products.
3
1 800 542 2334 | [email protected] | www.thermotekgroup.com V21310-VI1410
META
L
SYSTEM COMPONENTS AND WEIGHTS
*APPROXIMATE
OPTIONAL COATING TO REFLECTIVE FINISHED (TITLE 24 COMPLIANCE)
PART 2 – PRODUCTS
2.1 MATERIALS
A. THERMOTEK™ Self Adhesive 3.0 FP Granule
B. THERMOTEK™ Self Adhesive 1.5 FV Smooth
C. Asphalt Primer (ASTM D 41)
OPTIONAL COATING TO REFLECTIVE FINISHED (TITLE 24 COMPLIANCE)
A. THERMOTEK™ SILVER PLUS.
B. THERMOTEK™ GOLD PLUS
C. THERMOTEK™ PLATINUM PLUS
2.2 PRELIMINARY DETAIL INSPECTION
Inspect Preliminary Work/Flashing Details for problem areas (e.g., gaps, cracks, fishmouths, air pockets, etc.) to ensure
that work is complete and satisfactory. Inform Project Architect and THERMOTEK™ Technical Territory Representative
when all preliminary work and flashing details will be complete and the Installer is ready to proceed with application of
THERMOTEK™ ROOFGUARD Elastomeric Roofing Membrane. Allow a minimum of two weeks for the interim inspection.
Any final roofing installation prior to this interim inspection is subject to rejection by the Project Architect and/or the
THERMOTEK™. Please be advised that technical on-site support for instructing certified contractors in the proper
application of the THERMOTEK™ ROOFGUARD Roofing System is available.
2.3 PROCEDURE, COVERAGE RATE & APPLICATION INSTRUCTIONS.
A. Surface Preparation: Surface to be repaired or coated must be clean, dry and free of dust, dirt, grease, wax, or other
incompatible substances. THERMOTEK™ Self Adhesive restoration System is approved for application over CONCRETE roofs
having positive drainage.
1) Add additional fasteners to tighten laps where gaps exist. Gaps should not exceed ¼ inch in width.
2) Stripped, loose or missing fasteners should be replaced with the next larger diameter fastener size. Check all
fasteners to ensure they are tight.
3) Unsound rust should be scraped, wire brushed or sand blasted to remove all loose rust
4) Panels that are rusted to the point where their structural integrity may be compromised should be replaced with
new panels to match the existing.
5) Damaged panels should be replaced. New metal must be clean and oil free.
6) Remove all asphaltic-based patching and flashing materials. Do not apply solvents to remove asphaltic-based
materials. Remove asphalt coating with power washing, scraping or brushing.
7) Remove all silicone caulks and sealants. Acrylic coatings, primers and flashing grade products will not bond to
silicone caulks, sealants or coatings.
4
1 800 542 2334 | [email protected] | www.thermotekgroup.com V21310-VI1410
META
L
8) Remove and replace deteriorated pipe boots and other flexible flashing materials.
9) Surface to be repaired or coated must be clean, dry and free of dust, dirt, grease, wax, or other incompatible
substances, with THERMOTEK™ WASH and clean water, using power wash machine (1500 psi- 1 feet away).
10) All necessary repairs shall be made to the existing roof according to NRCA (National Roofing Contractors Association)
guidelines.
B. Apply a ASPHALT PRIMER (ASTM D 41) over the surface.
1) The coverage rate for ASPHALT PRIMER (ASTM D 41 is 1 gallon per 100 square feet.
2) In areas with mild rust apply an extra coat of ASPHALT PRIMER (ASTM D 41) at a coverage rate of 1 gallon per 100 square feet.
3) In areas with deep rust it is recommended to change the metal sheet.
C. Review all critical points over the Surface and repair them with THERMOTEK™ DURAMASTIC or Base Sheet THERMOTEK™ SELF
ADHESIVE 1.5 FV.
D. Apply THERMOTEK™ SELF ADHESIVE 1.5 FV smooth
1) The coverage rate for THERMOTEK™ SELF ADHESIVE 1.5 FV Smooth is a 1.80 SQ (theoretical coverage).
E. Apply THERMOTEK™ SELF ADHESIVE 3.0 FP GRAVEL.
1) The coverage rate for THERMOTEK™ SELF ADHESIVE 3.0 FP GRANULE is a 0.89 SQ (theoretical coverage).
OPTIONAL COATING TO REFLECTIVE FINISHED (TITLE 24 COMPLIANCE)
F. Reflective Surfacing THERMOTEK™ ROOF COATING.
1) The coverage rate for THERMOTEK™ ROOF COATING is a 2.0 gallons per 100 square feet, two coats of 1.00 gallon per 100
square feet each.
G. The applicator shall repair and/or replace any defective work found at the end of the job, before any warranties will be issued.
PART 3 – WARRANTY*
3.0 WARRANTY A. This system is eligible for a
1. THERMOTEK™ SELF ADHESIVE 1.5 FV SMOOTH + THERMOTEK™ SELF ADHESIVE 3.0 FP GRANULE, 10 YEARS LIMITED WARRANTY
B. This system is eligible for a TITLE 24
1. THERMOTEK™ SELF ADHESIVE 1.5 FV SMOOTH + THERMOTEK™ SELF ADHESIVE 3.0 FP GRANULE + THERMOTEK™ COATING SILVER
PLUS = 10 YEARS LIMITED WARRANTY
2. THERMOTEK™ SELF ADHESIVE 1.5 FV SMOOTH + THERMOTEK™ SELF ADHESIVE 3.0 FP GRAVILE + THERMOTEK™ COATING GOLD
PLUS = 11 YEARS LIMITED WARRANTY
3. THERMOTEK™ SELF ADHESIVE 1.5 FV SMOOTH + THERMOTEK™ SELF ADHESIVE 3.0 FP GRANULE + THERMOTEK™ COATING
PLATINUM PLUS = 12 YEARS LIMITED WARRANTY
Product Warranty – a Product Warranty states that our product is free of any defects in manufacturing . THERMOTEK™ will replace the
product when such product proves to be defective in manufacture as determined by THERMOTEK™.
PART 4 – CARE AND MAINTENANCE
4.0 CARE AND MAINTENANCE PROGRAM In order to ensure that your THERMOTEK™ Roofing Products will continue to perform to its fullest, you should follow, implement and satisfy this Care
and Maintenance program.
A. Maintain a file for all records relating to this roof, including the THERMOTEK™ Roofing Products agreements, reports, invoices, repair and
maintenance bills, original drawings and specifications, etc.
B. Inspect the roof and coating at least twice each year, typically in the spring and fall. The most common areas of damage or distress are at
drainage points, penetrations, perimeter flashings and in traffic areas.
C. Pressure wash the coating as needed (and not less often than once every 12 months) in order to remove all dirt and debris on the surface.
Wash using THERMOTEK™ WASH and clean water with appropriate pressure washing equipment (1500 psi – 1 feet away). Surface should be
maintained in clean white condition. Do not use anything but clean water unless directed by THERMOTEK™ Roofing Products and in such
case, use only approved wash products.
D. Inspect for damage from the elements after severe weather conditions, such as hailstorms, heavy rains, high winds, acts of God, etc.
E. Arrange for prompt repairs necessary to correct non-guaranteed conditions affecting the roof surface. Repairs to the surface must be
promptly performed by THERMOTEK™ Roofing Products approved contractors with approved products and repair methods that are
consistent with the type and quality of the warranted coating so that such repairs will last as long as the THERMOTEK™ Roofing Products.
F. Regularly remove any debris, such as leaves, branches, dirt, rocks, bottles, refuse, that may accumulate on the roof surface. Clean gutters,
downspouts, scuppers, and surrounding roof areas ensure proper drainage.
G. Examine all metal flashings, counter flashings, expansion joints and pitch pockets for rust, detachment, deteriorated sealant, and damage.
Reattach loose metalwork. Replace sealant as necessary. Prepare and paint rusted surfaces.
H. Examine masonry walls and copings for cracks, bad mortar joints, deteriorated sealant, loose masonry/coping stones, and indications of
water absorption. Repair all such conditions to prevent water infiltration.
I. Examine rooftop equipment such as air conditioners, ductwork, gooseneck vents, powered ventilators, evaporative coolers, antennas,
equipment screens, skylights, satellite dishes, etc. for excessive movement, spillage of coolant , condensation, oil, grease, water/liquid
release, etc., and damage to sheet metal cabinets and rubber or fabric gaskets that may allow water infiltration. Employ, keep and
maintain drainage systems for release of water, etc. from rooftop equipment to avoid surface water buildup. Keep all roof top equipment in
good condition.
J. Regularly examine for any cracks, blistering, or flaking. Promptly contact THERMOTEK™ Roofing Products representative regarding any such
cracks, blistering or flaking and recoat/patch any such areas with approved THERMOTEK™ products.
5
1 800 542 2334 | [email protected] | www.thermotekgroup.com V21310-VI1410
META
L
K. Minimize rooftop traffic. Establish paths which confine roof traffic to designated areas only. Service personnel should take care to avoid
dropping tools, equipment, parts, etc. on the roof surface. Service personnel should not make any penetrations of or repairs to the coating.
All work affecting the coating must be performed by an approved THERMOTEK™ Roofing Products contractor.
This THERMOTEK™ Roofing Products Care and Maintenance information is intended to address conditions commonly found on buildings. Other conditions may exist that
require special maintenance considerations. It is the responsibility of the Building Owner to ensure that the care and maintenance program followed for a particular
building is adequate, given that building’s specific conditions.
END OF SECTION