1
The Tradition and Science of Window Installations – Where are We Headed with More Highly Insulated Buildings?
EUROLINE TECHNOLOGY FORUM, OCTOBER 20, 2016
GRAHAM FINCH, MASC, P.ENG
2
A Brief History of Window Installation Practices in BC
Best Practices for Current BC Window Installations
Trends and Impacts of New Materials & Higher Performance Buildings
Integration of Windows into More Highly Insulated Walls – Do’s and Don'ts
Case Studies
Outline
4
The Perpetual Question
+ ?
5
We Have Come A Long Way in BC
6
Vancouver Early 20th Century
7
Early Window Installation “Best Practices”
8
Pre 1930’s Architectural Graphic Standards
From Ramsey & Sleeper – Architectural Graphics Standards
9
An Appreciation for Slope & Flashings
From Ramsey & Sleeper – Architectural Graphics Standards
10
Then Some Things were Forgotten in the 1980s
?
11
Building Enclosure Detailing Guidance Mid 1990s?
12
No Joke…
13
Oh and the Windows Leaked Too…
14
And We Had Lots of Condensation Problems
15
The Catastrophic Result…
16
Early Attempts at Sub-Sill Flashings without Good Water Shedding or Interface Details
17
Continually Evolving Best Practices in BC
18
Fundamentals: Following & Connecting the Critical Barriers
Water Shedding Surface (WSS) Water Resistive Barrier (WRB) Air barrier (AB)
19
Current Best Practices in BC for Rainscreen Window Installation
20
Evolving BC Practices
21
TOO MUCH Impermeable Peel and Stick
22
So What is Changing in BC? Trend towards more efficiently
insulated building enclosures due to higher energy code targets & uptake of passive design strategies
Greater attention to reducing thermal bridging in building enclosures
Many new building materials being introduced and imported into local market
Window installation practices are evolving to incorporate new and/or imported window frames into more highly insulated wall
Ongoing need to balance thermal and durability considerations
23
Evolution of Wall Assemblies to Passive Levels
Base 2x6 Framed Wall <R-16 (wood)
Exterior InsulationR-20 to R-60+
Deep Stud, Double Stud, SIPSR-20 – R-80+
Split Insulation R-20 to R-60+
Interior InsulationR-20 to R-30+
24
Deep Stud & Double Walls - w/ or w/o Service Wall
25
Consideration for Window Installs – Deep Walls
26
Exterior and Split Insulated Walls
27
Consideration for Window Installs – Exterior Insulation
Lots of Options including buck-outs with Varying Levels of Complexity!
Key detail – drain outboard of the insulation
33
City of Vancouver – R-22 Wall & Window Details
34
Industry Trends Impacting Walls & Windows Shift away from mechanically attached sheathing
membranes/WRBs like building paper & even synthetic membranes for more air-tight and taller buildings
Building Paper
RIP 2016
35
Trend Towards Combined Exterior Air Barrier (AB) Water Resistive Barrier (WRB) Approaches
Mechanically attached AB/WRB
Self-adhered vapour permeable sheet AB/WRB
Fluid applied vapour permeable sheet AB/WRB
36
Trend Towards Combined Exterior Air Barrier (AB) Water Resistive Barrier (WRB) Approaches
Sealed sheathing AB (adhesive tapes or sealants) with additional overlay WRB
Sealed coated sheathing AB/WRB
Sealed rigid foam insulation AB/WRB (special tapes)
38
Desire for More Vapour Permeable Materials?
39
New Good and Some Not-So-Good Vapour Permeable AB/WRB Membranes
40
Ongoing Research – Use of Vapour Permeable Liquid Flashings on Wood-frame Window Sills?
Can or should horizontal flashing membranes be vapour permeable like the jambs & head?
41
Assessing the Risk of Vapour Permeable Flashings on Window Rough Opening Devised a test which looks at the uptake of moisture ponding on a
horizontal window sill flashing into the framing lumber & sheathing over time
Compare results with control membranes that are known to fail or work well
42
0
5
10
15
20
25
30
35
40
45
0 Days 7 Days 14 Days 21 Days 28 Days 35 Days 42 Days
Moi
stur
e Co
nten
t (%
)
Plywood Edge - At Center
Are Vapour Permeable Liquids Safe for Use on Wood-frame Window Sills?
Safe MC <20%
not safe with these liquids or permeable SAM
safe with this liquid & impermeable SAM
maybe okay with these liquids?
Moisture Content of Edge of Plywood at Window Sill
43
Impact of the Wrong Liquid Applied Vapour Permeable Flashing on a Wood Window Sill
Mould after 30 days due to absorption into OSB sheathing below a relatively absorptive & permeable liquid applied window sill flashing
44
Definitely Not the Right Product for This Application
45
Oops! Someone Missed the Memo
46
Tapes as “Flashing” on a Horizontal Window Sill?
47
High Performance Buildings & Passive House Voluntary ultra-low energy construction standard Rapidly gaining interest & acceptance in North America Some codes targeting PH levels in next decade
>R-38
49
Some of BC’s First Passive Houses
50
Passive House Window Considerations Every single Watt (Btu/hr)
of heat loss matters within a Passive House It is a fine balance of a
building’s passive solar & internal gains compared to all of the conductive & convective losses
Heat loss through windows and installation details around perimeter becomes very important and often becomes a focal point for improvement (especially during construction!)
51
Standard Window Installation Details Aren’t Often Good Enough for PH Projects
Key considerations:• Avoid metal flashings that bypass
framing or insulation• Reduce wood framing around
window• Over-insulate the window frames
where feasible • Air tight (and properly water
managed)
Too much insulation displaced & too large of metal flashing
Too much wood
Too much wood
52
PH Details May Look more Like This!
53
PH Details May Look more Like This!
54
Some Frames Are Made to Hide With Insulation
55
Perimeter Heat Loss from Window Installations aka Linear Transmittance, psi-value - Window placement within the rough opening and the
detailing around the frame directly impacts the window perimeter heat loss & installed U-value/R-value
This factor is referred to as a linear transmittance, psi-value Bad psi-values = >0.040 W/m∙K Better psi-values = <0.020 W/m∙K Excellent psi-values = <0.010 W/m∙K
The psi-value is multiplied by the perimeter length of the window and energy added to the uninstalled window U-value to get an installed window U-value (i.e. it always worsens it) Impact on whole house with lots of windows can be significant,
especially when trying to meet stringent PH targets Typically modeled/calculated for specific details with some
baseline values provided by PH window suppliers
56
Certified Passive House Window Report Information
Window U-values
Frame U-values
Psi-values & Installed U-values
60
Window Installation Linear Transmittance Thermal Modeling
Window installation heat loss is the additional heat flow through the interface/gap/framing/flashings between the wall and window
62
Psi-Value Case Study: What Matters & How Much? Window:
Euroline 4700 ThermoPlus inswing tilt & turn with high performance triple glazing (U-0.75 W/m2∙K, R-7.6 IP)
Walls: Split insulated 2x6 wood frame filled
with fiberglass batt and 6” exterior mineral wool with long screws through insulation to support cladding (R-40 effective)
Windows installed at inner, middle and exterior of wall with and without additional insulation over the frames
Additional data for deep stud 2x10 w/ interior 2x4 service wall (R-40) also provided in handouts (no time today!)
63
Split Insulated Wall – Standard Install, No Insulation Over Frames
This means that the window U-value gets 16% worse just by installing it Seems small but it does matter when talking about the performance of Windows
64
Split Insulated Wall – Impact of Over Insulating Frames
16% loss in window U-value for no over insulation vs 8% with
No impact to worst case modeled window surface temperature, <1°C at jamb/head
Watch temperatures if insulating on inside!
If over-insulatingat sill watch drainage!
65
Split Insulated Wall – Impact of Placement in R.O.
Based on window size of 1.2 x 1.5 m. Cladding not modeled for conservative estimate
Window towards the exterior is better thermally, small impact on interior surface temperatures
66
Split Insulated Wall – Impact of Placement in R.O. with Over Insulating Frames
Based on window size of 1.2 x 1.5 m. Cladding not modeled for conservative estimate
Over insulation drops psi-value by about half
Placement impact is similar, middle is slightly better
71
Window Size Matters!
0
2
4
6
8
10
0 2 4 6 8 10
R-Va
lue
(IP)
Length and Width of Frame (ft)
Thermal Performance of Euroline 4700 Frame - Center of Glass vs Window vs Final Installed By Size of Frame
Center of Glass Window InstalledWhat really matters
72
Rigid Foam Below & Supporting Window Frames? Thought by some PH designers or
modelers that it may be worth replacing one of the wood sill plates (200 to 900 psi compressive strength) with XPS insulation (30 psi compressive strength @ 10% compression)
Weight on setting block shims for a typical triple glazed passive house window (several hundred pounds) will be in the order of 100 to 200 pounds well over 30psi unless large distributed
shims or over more wood? Most shims are only a few square
inches in area – therefore foam compresses initially or over time damaging installation, seals and potentially window
73
Possible Benefit of XPS Below Window Sill – If Bearing Capacity Can Be Addressed
Can see why it might be suggested but for a 2% difference I would look for other improvements unless bearing issues are addressed
76
Bella Bella Passive House Case Study Design Build project for Vancouver
Coastal Health for a 6-plex staff housing to replace housing that had burned down
Target of passive house certification and delivery in 6 months
First modular Passive House in Canada
First Passive House in a First Nations Community
77
The Window Details!
2x6 wood frame wall with 6” exterior insulation
78
Split Insulated Passive House Window Installation
79
Split Insulated Passive House Window Installation
80
Split Insulated Passive House Window Installation
81
Split Insulated Passive House Window Installation
82
Split Insulated Passive House Window Installation
83
Modular Passive House Construction
84
Modular Shipping
85
Site Assembly & Completion
86
Key Conclusions Long history of iterative progress in
the installation of windows in British Columbia – many past failures and successes
Evolution is continuing with higher performance windows (imported and locally made in more highly insulated wall assemblies
Be careful with the selection of new membranes, flashings, tapes, sealants and foams – ensure durability and moisture control while balancing thermal needs
Always look at continually improving the thermal performance of your window installation details!