Teaching equipmenT designer and manufacTurer
Turbines .................................................... p. 181
radiaTion ................................................ p. 185
engines ................................................... p. 187
eVaporaTion-condensaTion . p. 188
ThermicaLs eXchange ............... p. 190
ThermodYnamics .......................... p. 197
conVecTion ....................................... p. 198
conducTion ...................................... p. 203
compressor ........................................ p. 204
3
5
6
8
7
9
2
4
1
Teaching equipmenT designer and manufacTurer
thermodynamiCS
180
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
181
Thermodynamics Turbines1
• presentation constituent elements of an impulse turbine• determination of the characteristics of power and torque of the tur-
bine as a function of the rotational speed.• study of the influence of the air flow rate on the power• study of the influence of the number of nozzle used• cycle plotting on diagram Ts (-entropie temperature)• isentropic efficiency of the turbine
EXPERIMENTAL CAPABILITIES
Turbine• Turbine single stage with axial flux ; maximum speed: 35000tr/
min; max power: 45W
injecTion nozzles• four nozzles with isolation valves.
brake• brake with belt mounted on the shaft of the turbine. The cooling is
assured by a compressed air supply
TorquemeTer• force sensor with strain gauge and indicator on the panel
TemperaTure• measurement of the air inlet and outlet of the turbine by probe pt
100 three wires
air flowraTe• float flowmeter with glass tube at the turbine outlet
roTaTion speed• optical sensor with npn converter
pressure manomeTer• manometer with bourdon tube scale of -1 to +1 bar
safeTy valve:• prevents the overpressures in the turbine
filTer regulaTor:• purifies the compressed air supplying the machine and reduces
the pressure
needle• ensures the adjustment of the tension of the belt of the brake of
the turbine
TEChNICAL dETAILS
supply• electricity: 230 V / 50 hz• compressed air: 7 bars
dimensions• LxWxh: 800x500x600 (mm)/Weight: 25kg
SERVICES REQUIREd
Impulse turbIne
TAA 100
182
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
Turbines1
• study of the operation of a gas turbine with two shaft lines inde-pendent to propane.
• flow rate measurement, pressure, temperature, angular velocity and torque
• measurement of electrical power.• angular speed regulation• Yields• safeties
EXPERIMENTAL CAPABILITIES
cenTrifugal venTilaTor• compression 0.5 to 0.7 bars• air flow rate up to 500m3/h• Two operating modes
- Ventilator - auto supply
• filters to the supply
generaTing Turbine • a single stage centrifugal compressor
- compression ratio of 1.2 to 3 - air flow rate of 100 to 700 kg/h
• a single stage turbine - Keyed onto the compressor shaft - powered by the expansion of the gases coming from the com-bustion chamber
combusTion chamber• resistant stainless steel• Visualization hublot of flame• air supply by the compressor• propane supply• propane-air mixture• ignition by electric arc
circuiT propane• mano pressure reducer• solenoid Valve of ignition• solenoid valve normal operation• flowmeter of propane
a power Turbine• fueled by the expansion of gases escaping from the generating
turbine• speed reduction ¼• dc generator
- speed max 3750 rev/ min - power max 1.5 KW
cenTral of lubricaTion Turbines• distribution on the two shafts• exchanger water / oil
measures• 6 temperature measurements• 6 pressure measurements• 2 flow rate measurements• 2 rotation speed measurements turbines• 1 power measurement
manual seTTings• propane pressure• propane flow rate• powered by ventilator and self-power• power turbine speed
safeTies• combustion chamber temperature• Lubricating oil temperature• combustion chamber inlet air pressure• cooling system water pressure• detection of the flame• dc generator speed• speed variator default
TEChNICAL dETAILS
supply• electricity: 400V three-phase + n + T – 25kW• Water: mains network supply• propane: standard bottle
dimensions• LxWxh: 2000x825x2000 (mm)
SERVICES REQUIREd
Gas turbIne unIt two shafts
TgT 1,5 kw
183
Thermodynamics Turbines1
operaTion of a sTeam Turbine uniT• steam boiler• steam turbine• alternator• Yields
measuring devices on The differenT circuiTs• Temperature• Level• pressure• flow rate
calculaTion of yields• steam boiler• superheater• steam turbine• steam condenser• cooling tower
sTudy and analysis on a waTer TreaTmenT sTaTion
EXPERIMENTAL CAPABILITIES
sTeam boiler• permanent presence boiler with safeties• control box with alarm signaling by siren• 10 bar utilization pressure• oil burner
sTeam Turbine• steam turbine 1kW• rotation speed: 3000rpm• supply pressure: 10 bar• mechanical overspeed regulator• power-off valve
alTernaTor• direct mechanical connection to the turbine• production: 1000W-50hz to 1500rpm• production control by potentiometer dissipation of energy on elec-
tric resistors
cooling Tower• open tower with forced ventilation• power used: 90KW• Water circuit in continuous flow rate 6 m3/h
sTeam condenser• Tubular exchanger (water in the tubes)• recovery of condensates towards the feedwater tank by mecha-
nical pump
waTer Tank• Volume: 250L• material: stainless steel• controls: level, temperature• heating by the steam with injection nozzle• boiler supply pump
Tank fuel oil supply• Volume: 250L• material: stainless steel• controls: level, temperature• retention bin in the lower part
waTer TreaTmenT• automatic softener with regeneration of the resins• salt bins• Water treatment by adding specific product by dosing pump
elecTrical superheaTer• steam outlet temperature: 210 °c• digital pid temperature control
TEChNICAL dETAILS
supply• electricity: 400V three-phase + n + T – 20kW• Water: mains supply
evacuaTions• fumes of the boiler• Wastewater• Valve discharge ducts
dimensions• boiler:
- LxWxh: 2000x1200x2000 (mm)• utilities group:
- LxWxh: 2300x1000x2000 (mm)• Turbine group:
- LxWxh: 1800x1000x2000 (mm)• cooling tower:
- LxWxh: 1200x1200x2200 (mm)
SERVICES REQUIREd
steam turbIne unIt 1kw
TvT 1 kw
184
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
Turbines1
operaTion of a ThermoelecTric uniT• steam boiler• steam turbine• Yields
measuring devices• Temperature• Level• pressure• flow rate
safeTy devicesThermal exchanges• steam water• electric steam • Water combustion • Water air
waTer TreaTmenT
EXPERIMENTAL CAPABILITIES
sTeam boiler 134 000kcal / h• 4.1m² heating surface• maximum temperature 192 °c• steam production 210kg/h• maximum pressure 12 bar• diesel burner• sensors temperatures, flow rate, level, pressure and safety.
sTeam user group 3600 rpm• steam turbine output atmos pressure or vacuum 3kW• Vortex effect flowmeter• pressure and temperature safety sensors
3. dynamomeTer 4.6 kva• connected directly to the turbine• data• rotational speed Torque, ammeter, Voltmeter• braking of the turbine• charge dissipation resistors
cooling Tower• open air circuit flow rate 1.7m3/s • Water circuit in continuous flow rate 15 m3/h
sTeam condenser• exchange surface 2.7m²
waTer Tank and condensaTes 250l• stainless steel• Temperature level safeties controls• steam heating• boiler supply pump
fuel supply conTainer 250l• stainless steel• glass level• sensor temperature and safeties
waTer TreaTmenT• automatic softener with regeneration of the resins• salt bins 100L• dose group with volumetric pump 100L
elecTrical superheaTer• 8kW power• measurements of temperature, pressure and safety• steam flow rate 210 kg/h• steam temperature 240 °c
desuperheaTer• exchanger plates 0.6m²• circulation pump 3.5m3/h• inlet temperature 240 °c• outlet temperature 188 °c• control and regulation outlet temperature
TEChNICAL dETAILS
supply• electricity: 400V three-phase + n + T – 12kW• Water: mains network supply
dimensions• LxWxh: 4000x3000x3000 (mm)
SERVICES REQUIREd
steam turbIne unIt 3kw
TvT 3kw
185
Thermodynamics radiaTion2
• study of thermal radiation• emission - absorption.• demonstration of the laws of Kirchoff and LamberT and in-
verse squares.• surface temperature measurement by infrared.• influence of the distance and of the orientation of the source.
EXPERIMENTAL CAPABILITIES
rail guides• profile anodized aluminum, graduated, mounted on adjustable
feet
infrared ThermomeTer• output 4-20 ma• With sighting device
Thermal source• mounted on graduated rotary support• heating element 675 watts• extension black surface at high yield • ssr variable power• pid digital regulation
differenT aluminum plaTes equipped wiTh probes pT100 Ω of surface:• shiny black plate• matt black plate• White plate• plate without paint
radiomeTer 0-1000 mw / cm²• measuring probe of radiance 0.2 to 1000 W/cm²
insTrumenTaTion• plates temperature indicator• indicator of surface temperature• (infrared thermometer)• programmable pid temperature controller
TEChNICAL dETAILS
supply• electricity: 230 V mono - 50/60 hz - 16 amp.
dimensions• LxWxh: 2000x500x900 (mm)/Weight: 30kg
SERVICES REQUIREd
study of thermal radIatIon
pbr 010
186
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
radiaTion2
• study of thermal and luminous radiation.• demonstration of the laws of Kirchoff and LamberT and the
inverse squares.• Thermal and luminous energy according to the distance.• emission, absorption, reflection.
EXPERIMENTAL CAPABILITIES
rail guides• profile anodized aluminum, graduated• mounted on adjustable feet
luminous source• mounted on graduated rotary support• 100 watt lamps - adjustable diffusion
colour filTers
plaTe wiTh variable orifice iris Type
lux meTer 0 – 100 000 lux• With analog output 0-1 Vdc
Thermal source• mounted on graduated rotary support• heating element 675 Watt• extension black surface at high yield • ssr variable power• pid digital regulation
differenT meTallic plaTes equipped wiTh probes pT100 of surface
radiomeTer 0 – 1000 mw/cm2• With analog output 0-1 Vdc
insTrumenTaTion• indicator of surface temperature• indicator of luminous intensity and of thermal energy
infrared ThermomeTer• output 4-20 ma
TEChNICAL dETAILS
supply• electricity: 230 V mono - 50/60 hz - 16 a
dimensions• LxWxh: 2000x500x900 (mm)/Weight: 30kg
SERVICES REQUIREd
study of thermal and lumInous radIatIon
pbr 100
187
Thermodynamics engines3
• identification of components of a diesel engine and gas• determination of the torque and of the power according of the speed
of rotation• comparison of the practical results and the theoretical results• determining the overall efficiency of a diesel or gasoline engine (fuel
consumption and air, output power ...)• study of a four-stroke gasoline engine single cylinder• study of a single cylinder diesel engine.
EXPERIMENTAL CAPABILITIES
gasoline engine wiTh The following specificaTions• Type: single cylinder, cooling air• cylinder: 270 cm3• power: 6.3Kw (8.5hp) @ 3600rev / min• maximum speed: 3700rpm• compression rate: 8.5: 1• bore x stroke: 77x58mm
diesel engine wiTh The following specificaTions• Type: single cylinder, cooling air• cylinder: minimum 349cm3• power: 5.5Kw (7.5hp) @ 3600rev / min• speed maximum: 3700rev /min• Torque: 16.6nm@2400rev/min• bore x stroke: 82x66mm
an elecTric brake (brushless moTor) wiTh The fol-lowing specifications:• dc-motor with variator• fan of cooling• maximum speed: 4000rev/min• maximum power: 10.5kW• adjustment of the rotational speed by potentiometer
Two Tanks (one for each fuel) compatible with diesel and gasoline. The connec-tion towards the engine is done via quick connectors. The tanks also included a filler cap, a blowhole, and a return connection for the diesel
an elecTric box• comprising the switching on buttons, Leds, the circuit breakers
necessary for safe operation of the equipment.
The engine parT is equipped wiTh a safeTy posiTion deTecTor
all The insTrumenTaTion below• measure of engine torque• measure of the speed of rotation• measure of the exhaust temperature• measure of the air flow rate• measure of a fuel consumption
The sysTem comes wiTh compleTe documenTaTion in english including:• Technical manual of use• Technical documentation of components• electrical diagram• a series of practical work• The documents are provided in electronic form in pdf or word
format
TEChNICAL dETAILS
supply• electricity: 400Vac-tri-phase + neutral + earth-50hz• diesel (20L)• gasoline (20L)
dimensionsengine part:• LxWxh: 1500x800x1300 (mm)/Weight: 350kg
utilities part:• LxWxh: 1100x800x1900 (mm)/Weight: 130kg
SERVICES REQUIREd
test bench of combustIon enGInes
TmT 400
188
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
eVaporaTion-condensaTion4
• observation of the change in phase from liquid to vapour while heating the refrigerant. This unit permits observation of - convection currents - heat transfer - Various states of the refrigerant from supercooled liquid to overheated vapour.
• observation of the disruptive effect of air in a condenser
EXPERIMENTAL CAPABILITIES
• glass concentric tube exchanger• pump and thermoregulator 500 W• refrigerating fluid tank with water condenser• air ejector with fountain (vacuum pump)• control valve for the condenser water flow rate• emptying and vacuum valve• safety valve• manometer• flow rate valve of the refrigerant.
TEChNICAL dETAILS
supply• electricity: 230 V single-phase - 50 hz – 0.5 kW• Water: 0.15 m3/h (refrigeration)• 0.5 m3/h (vacuum pump) 2 bars
dimensions• LxWxh: 400x400x1800 (mm)/Weight: 35kg
SERVICES REQUIREd
demonstratIon of boIlInG
pbe 010
189
Thermodynamics eVaporaTion-condensaTion4
study bench of the condensatIon
bec 010
• Visualization of the condensation in drops and in film and of the boil• study of heat transfers• study of the relation temperature / pressure for the water at saturation.• Visualization of the effect of air in a condenser.
EXPERIMENTAL CAPABILITIES
• glass Tube• heating resistance• heating control (3 kW maxi)• flowmeters (two)
- 50 to 800mL / min - 0.3 to 3 L / min
• condensers (two) (with drops, - With film)
• separator• cooler• manometer -1 to 1.5bars bar• safety valve• air ejector with water jet (vacuum generator)• exhaust air valve• ejector control valve• eleven temperature measurements
- Three by condenser - four for the inputs and outputs of water - one for the boiling temperature.
TEChNICAL dETAILS
supply• electricity: 230 V mono 50 hz – 3 Kw• Water: 3L/min maxi (2,5 bars required)
dimensions• LxWxh: 700x700x600 (mm)/Weight: 50kg
SERVICES REQUIREd
190
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
ThermicaLs eXchange5
• co-current thermal exchanges.• Thermal exchanges counter-current.• Laminar or turbulent regime.• Thermal balance on the exchanger.
EXPERIMENTAL CAPABILITIES
waTer reheaTer• capacity: 5 liters• settings of + 25°c to + 100°c• power 2000 W• agitation system included
hoT circuiT• closed circuit
exchanger• With concentric tubes• material: stainless steel• exchange surface: 168.6cm²
TemperaTure sensors T• 4 sensors: inputs and outputs• T type thermocouple• input and output of each exchanger circuit
flowmeTers• 2 flowmeters: hot and cold circuit• circuit hot: 50 to 800mL/min• cold circuit: 0.2 to 1.5L/min
valves• 2 setting valves hot and cold flow rate • multi-turn valves with needle
circulaTion pump• centrifugal pump
cold circuiT• connected to the network
TEChNICAL dETAILS
supply• electricity : 230 V single phase-20a– 50 hz• Water : 2 l/mn-3bars
dimensions• LxWxh: 1000x500x620 (mm)/Weight: 40kg
SERVICES REQUIREd
bench of thermal exchanGe mono-tubular
beT 010
191
Thermodynamics ThermicaLs eXchange5
• Visualization of boiling and condensation processes• effect of temperature and pressure on the evaporation process• highlighting of the increased efficiency of the heat exchanger with the
increased of number of interchange circuits for a constant flow rate• measuring the effect of the increase of the flow velocity of the cooling
fluid and the number of interchange circuits on the heat transfer coef-ficient
• study of the relation pressure/saturation temperature for water at low pressure..
EXPERIMENTAL CAPABILITIES
• Three heating resistance • power regulation
- realize with a potentiometer • glass cylinder 1200 ml
- realize the evaporating liquid and condensation liquid on the exchangers
• four tubes coolers in stainless steel - with possibility of connection of several different ways (using the distributor)
• Temperature sensor probes (7) - 7 x Thermocouple : type T, 0...100°c
• differential manometer - measuring the losses in selected exchangers
• flowmeter and with control valve and sensor of flow - range cooling water : 0,2-1,5 l/min
• distributor - selection 1 circuit….4 circuit exchange
• steam manometer and pressure sensor - measuring the pressure in the chamber, range 0-10 bars
• overpressure valve 5 bars• drain Valve• Water inlet valve• Low level sensor to protect the resistances
TEChNICAL dETAILS
supply• electrical supply: 230 V mono – 50 hz – 16 a • Water supply: 2L/min – 3 bars
dimensions• LxWxh: 450x400x620 (mm)/Weight: 30kg
SERVICES REQUIREd
boIlInG process heat exchanGer steam – water
beT 020
192
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
ThermicaLs eXchange5
sTudy of Thermal exchanges:• convection in a copper tube• exchange coefficient between the copper and the water (reY-
noLds number, brandT and nusseLT)• Thermal resistance due to copper• coefficient of exchange between the copper and the steam• power balance received by the water and deduction of heat losses• calculation of the specific heat of the refrigerant fluid r141b
laminar and TurbulenT regime• Vaporization phenomenon (evaporation and boiling) and
condensation.
EXPERIMENTAL CAPABILITIES
• Low voltage indicator• Voltmeter• ammeter• Temperature indicator• manometer• power regulator• Temperature selection• Turning on the heating resistance• button that allows you to read the electrical power
TEChNICAL dETAILS
supply• electricity: 230 Vac mono - 50/60 hz - • Water: network - 16 l/h
dimensions• LxWxh: 650x450x650 (mm)/Weight: 40kg
SERVICES REQUIREd
bench of thermal exchanGe VaporIzatIon prIncIpe
beT 030
193
Thermodynamics ThermicaLs eXchange5
• co-current thermal exchanges• counter-current thermal exchanges• highlighting the laminar and turbulent regimes
EXPERIMENTAL CAPABILITIES
• a heat exchanger with concentric tubes• a tank for returning of the hot water
- stainless steel - Volume 70 liters
• centrifugal pump with magnetic drive• electrical resistance (3 KW) of heating the water• Low level probe• safety thermostat• Temperature probe for heating regulation• hot water flowmeter 1-10 l/min 9.• flowmeter hot water 10-90 l/h• cold water flowmeter 10. 20-180 l/h• flowmeter cold water 1-10 l/min• 6 thermocouples type T• filling valve• 4 selection valves co-current • cold water inlet valve• drain Valve• Valve of bypass
TEChNICAL dETAILS
supply• electricity: 230 V mono – 4 KW• Water network
dimensions• LxWxh: 1700x700x1600 (mm)/Weight: 100kg
SERVICES REQUIREd
concentrIc tubes exchanGer
beT 040
194
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
ThermicaLs eXchange5
• comparative study of three technologies of exchangers: plates, stainless steel tubular beam with glass calender, glass tubular beam with glass calender
• comparison of a co-current circulation and of a counter-current• calculation of thermal power• calculation of exchange coefficient• study of the influence of water flow rates
EXPERIMENTAL CAPABILITIES
The bench beT100 allows the study of three industrial type heat exchan-gers. The bench comprises a reserve bin with a resistor which produces the hot water. cold water comes from the establishment network. The students will first need to select the exchanger to study and connect the inputs and outputs of water using hose equipped with self-sealing cou-plings. The flow rates are adjusted using multi-turn valves with handle.after a stabilization period, students must identify the operating parame-ters (temperature, flow rate) to calculate the different values required for the practical exercisesThe robust design of this equipment makes it suitable for use in schools.anodized aluminum structure on wheels gives it a very robust as well as a high flexible integration into your premises. The manufacturing of this equipment meets european machine directive• flowmeters of cold water with needle adjusting valve and selection
valve of the flowmeter used. scales: 15-150L/h and 100-1000 L/h• stainless exchanger plates, surface equal to 0.5m² minimum. equip-
ped with four temperature measurement at the input and output of cold water and hot water, circulation mode selection using self-sea-ling quick couplings
• stainless exchanger with stainless tubular beam, surface equal to 0.5m² minimum. calender glass with drain valve at the lower part. equipped with four temperature measurement at the input and output
of cold water and hot water, circulation mode selection using self-sea-ling quick couplings
• hot water tank with stainless steel and with lid. effective volume: 100L. heating resistors: 15KW. Low level sensor and built-in safety thermostat
• electrical supply box. including: protection (circuit breakers ..) power supply switch, button to switch on, multi lane indicator for tempera-ture probes of the exchangers and tank temperature indicator with thermostat
• flowmeters of hot water with needle adjustment valve and valve se-lection of the flowmeter used. scales: 15-150L/h and 100-1000L/h
• exchanger with glass tubular beam, surface equal to 0.5m² mini-mum. calender glass with drain valve at the lower part. equipped with four temperature measurement at the input and output of cold water and hot water, circulation mode selection using self-sealing quick couplings
• pump for circulating the hot water in stainless steel. max pressure: 2.3bars. max flow: 3000L/h. maximum temperature of the pumped water: 100 °c
TEChNICAL dETAILS
supply• power supply: 400 Vac - 50 hz - 32 a• power supply type: 3phase (s) + neutral + earth.• Water supply: 20 L/min - 2 bars• Water drain: at ground level• Water capacity: 100 L• dimensions (LxWxh mm): 1800x800x1780• Weight (kg): 180
dimensions• LxWxh: 1800x800x1780 (mm)/Weight: 180kg
SERVICES REQUIREd
study bench of 3 exchanGers
beT 100
195
Thermodynamics ThermicaLs eXchange5
study bench of the thermal exchanGes
STL 600
• study of a plate thermal exchanger• calculation of the thermal balance• calculation of effectiveness of the exchanger• calculation of the exchange coefficient• influence of the flow rate of cold water• influence of the hot water temperature
EXPERIMENTAL CAPABILITIES
flowmeTer of cold waTer• scale from 0.2 to 1.5L/min• glass tube• stainless floater
brazed plaTe exchanger• input at low point• output at high point• possibility to switch to counter-current
T. TemperaTure probe• Type pt100• connection 3 wires• four probes placed at the entrance and exit of the heat exchanger
insTrumenTaTion:• The bench includes a digital display for temperature probes. it
simultaneously displays 3 temperatures. The scrolling can be ma-nual or automatic.
TEChNICAL dETAILS
supply• electricity: 230 Vac mono – 50 hz-10a• cold water: 1,5 l/mn (network)-20°c maxi• or supply by the bench sTL050• hot water: 0,5 l/mn-40°c mini• (supply by the bench sTL100)
dimensions• LxWxh: 580x400x660 (mm)/Weight: 20kg
SERVICES REQUIREd
196
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
ThermicaLs eXchange5
coolInG tower
pTr 010
chamber of air disTribuTionvariable flow raTe cenTrifugal fan
cooling Tower TransparenT• With three different linings:• coarse honeycomb • fine honeycomb • honeycomb with perforated surface
diaphragm for The measuremenT of The air flow raTe
differenTial pressure manomeTer connecTed To The diaphragm
group of waTer heaTing• Water volume : 7L• power : 3500W• Low-level security for the prote the resistance
genTrifugal pump of circulaTion• 1,8 m3/h – 21 mce
h. floaT flowmeTer • 0 – 150 L/h
valve flow raTe regulaTing of hoT waTerauxiliary auTomaTic waTer• Water is contained in a graduated tank• (consumption measurement)• The solenoid valve auxiliary is controlled by a level sensor in the
group f
TemperaTure measuremenT• t1: water of group• t2: departure water tower• t3: return water tower• t4: air inlet tower• t5: air outlet tower•
measuring relaTive humidiTy• h1: air humidity input tower • h2: air humidity output tower
TEChNICAL dETAILS
supply• electrical supply: 230 Vac – 50 hz – 20 a • Water: filling tank, very low consumption
dimensions• LxWxh: 900x600x1200 (mm)/Weight: 45kg
SERVICES REQUIREd
• study of the thermal exchange water/air-thermal balance yield.• monitoring the evolution of the air on the psychrometric diagram.
EXPERIMENTAL CAPABILITIES
197
Thermodynamics ThermodYnamics6
• study of the rankine cycle.• plotting of the combined cycles on enthalpy diagram.• calculating the cooling capacities at the evaporator, to the condenser
with the ejector-compressor, as well as steam generator.• calculation of thermal balances to the exchangers• calculation of the yields.
EXPERIMENTAL CAPABILITIES
refrigeranT sTeam generaTor• Volume 0,68 l• preheat liquid coil 1/4Ø
ThermoregulaTor group• capacity 5 l• heat transfer fluid: oil• power 2 kW
ejecTor-compressor• suction and compression of the refrigerant steam
condenser• glass casing - copper coil• cooled by water
a diaphragm pump wiTh variable flow raTe• equipped with nonreturn valves at the suction and discharge• maximum pressure: 10 bar• maximum flow rate: 20 l/h
evaporaTor• glass calender• Variable power cartridge heater• expansion Valve
insTrumenTaTion• Three measures of pressure• Ten temperature measurements by thermocouple T (Ti)• digital temperature indicator• Variable area flowmeter and control valve on the water to the
condenser• ammeter, voltmeter on the supply to the heating cartridge with
variable power.
TEChNICAL dETAILS
supply• electricity: 230 Vac-20a - 50hz• Water: 250 l/h
dimensions• LxWxh: 1000x670x650 (mm)/Weight: 80kg
SERVICES REQUIREd
study of the rankIne cycle
crr 100
198
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
conVecTion7
• determination of heat transfer and of the exchange coefficient for a transversely placed tube in a flux
• determination of the coefficient of exchange for a tube placed in a bundle of tubes in staggered rows
• determination of the exchange coefficient for a cross exchanger tubes in staggered rows
• determination of the numbers reYnoLds prandTL, nusseLT• same applications for a finned tube in an exchanger in staggered
rows.
EXPERIMENTAL CAPABILITIES
fan-moTor ensemble• equipped with an output damper for control of the flow rate
measuring ducT equipped wiTh a manomeTer for flow raTe measuremenT, Two Thermocouples for TemperaTure measuremenT• This duct can be equipped with one of the three arrangements
described above.
conTrol panel wiTh:• a power on button• fan control• The heater control of the heating cylinder (the cartridge is equip-
ped with a thermocouple) with indication of the power• The display of the temperature of the air duct
TEChNICAL dETAILS
supply• electricity: 230 V mono – 50 hz
dimensions• LxWxh: 800x500x1800 (mm)/Weight: 30kg
SERVICES REQUIREd
exchanGer by conVectIon
pTc 050
199
Thermodynamics conVecTion7
highlighting the free and forced convection. heat transfer measure-ment in free or forced convection in the following cases:• flat vertical plate• exchanger consists of several lines of cylinders• exchanger with vertical thin plates
EXPERIMENTAL CAPABILITIES
• air duct rectangular and its chassis• Test turntable (three possible arrangements)• Variable speed fan• hot wire anemometer• Temperature probes• control box with:
- heater control - control of the fan speed - Temperatures display
TEChNICAL dETAILS
supply• electricity: 230 V mono - 50/60 hz
dimensions• LxWxh: 800x500x1800 (mm)/Weight: 30kg
SERVICES REQUIREd
free and forced conVectIon
pTc 060
200
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
conVecTion7
study bench of heat transmIssIon
pTc 100
• study of thermal exchanges on a plate by forced convection.• influence of the inclination of the plate on the transmission of heat to the
ambient air by free convection and radiation.• study of the different thermal conductivity of insulating materials.
EXPERIMENTAL CAPABILITIES
The bench of the heat transmission is composed of:• an aluminum profile chassis equipped with a heating plate sup-
port with tilt and variable positioning and an inclined plane console.
• a heating plate - homogeneous heating with power below 300 watts - Very low thermal inertia
• a set of plates of different insulating materials of which their ther-mal conductivity will be determined.
• a variable speed fan (variable flow rate) to study the transmission of heat by forced convection.
• The instrumentation: - a temperature regulator associated with a power metering - setpoint between the ambient and 70 °c
- a fan speed controller - a voltmeter and an ammeter for the holding power measure-ment in temperature
- a surface temperature probe and ambient temperature - electrical safety.
TEChNICAL dETAILS
supply• electricity: 230 V mono - 50/60 hz
dimensions• LxWxh: 880x530x570 (mm)/Weight: 20kg
SERVICES REQUIREd
201
Thermodynamics conVecTion7
heaTing• Temperature range: 0 to 299 °c• heating method: electrical resistance• Type of regulation: digital by regulator with thyristor block• accuracy: 0.1 °c
cooling• Type of cooling: water exchanger (coil) supply by network• cooling control: manual multi-turn valve• measurement: float flowmeter and digital display of the exchanger
temperature (input and output)
pressure• measurement: digital vacuometer connected to a pressure sensor• measuring range: 1 to –0.95 bar• production of vacuum: vacuum pump (included in the bench)• pressure range: 1 to –1 bar
elemenTs of measuremenT (sensor)• shape: circular• quantity: 2• colors: gray and black• measurement: digital display of the temperature of each sensor
TEChNICAL dETAILS
• calculation of exchanges by radiation and convection• draw the warm-up and cooling curves of the two bodies• draw the absorption and emission curves of the two bodies under
vacuum.
EXPERIMENTAL CAPABILITIES
supply• electricity : 220/240 Vac single phase + earth – 50 hz –600W• Water: network 0,4l/min-2bars.
dimensions• LxWxh: 800x600x700 (mm)/Weight: 45kg
SERVICES REQUIREd
study bench of natural conVectIon and radIatIon
pTc 040
202
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
conducTion8
• study of thermal exchanges by conduction.• study of the laws of linear and radial conduction.• determining the thermal conductivity of different materials.• study of the resistance of a contact surface and of the variation.• List of temperature gradients according to different transfer levels.• study of the influence of the addition of a conductive paste
between the samples and the heat source..
EXPERIMENTAL CAPABILITIES
The sTudy uniT of The Thermal conducTion is com-posed of: • an aluminum chassis profile with a linear conduction study mo-
dule and a study module of the radial conduction; the whole equipped with a connectable cooling circuit.
• an electric console comprising: power regulation / temperature of the heating elements, analog interface / digital of the set of modules temperature probes. usb output for visualize in real time the heat transfer and the temperature measurements.
• The linear conduction study unit• metal cylinder Ø 25 mm heat emitter, isolated from the outside,
with three temperature probes distributed linearly.• metallic cylinder of heat receptor, isolated from the outside, with
three temperature probes. This element is cooled by the circula-tion of cold water.
• The demonstration cylinders, Ø25 brass, stainless Ø25, Ø15 brass, of different metals, are isolated from the outside, and are equipped with three temperature probes spaced apart linearly. The sample change occurs rapidly by simple action on a spring clamping lever. This module allows to study the influence of the nature of the materials and the contact surface between the ele-ments on the transmission of heat energy.
• study module of the radial conduction• a metal disk, isolated from the outside, is heated in its center.
six probes spread linearly between the center and the periphery (cooled by circulating water) allow to follow the propagation of heat.
TEChNICAL dETAILS
supply• electricity: 230 V mono phase – 50/60 hz• Water network supply:3 l/min• pc not supplied
dimensions• LxWxh: 800x500x1800 (mm)/Weight: 30kg
SERVICES REQUIREd
study of the thermal conductIon
pcT 010
203
Thermodynamics conducTion8
• measuring of the conductivity of liquid and gas after calibration of the unit with the air.
EXPERIMENTAL CAPABILITIES
• cold source of cooling - supply by water circulation type « WaTer JacKeT »
• cylindrical hot source - internal cylinder equipped with a heating cartridge
• heating cartridge (100 W)• annular space containing the fluid to be studied
- disposition of the liquids or the gas• control box including:
- The power regulator and its indicator - a temperature indicator with channel selector
• a voltmeter / ammeter
TEChNICAL dETAILS
supply• power supply: 230 V mono - 50hz - 20a• Water supply: 3 to 5 L/min – 3 bars
dimensions• LxWxh: 300x300x300 (mm)/Weight: 9kg
SERVICES REQUIREd
study of the thermal conductIVIty of lIquIds and Gases
pcT 020
204
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
compressor9
• study of a compressor• power• Yield• Work• flow rate• pressure• study of diaphragms• pressure-flow rate report.
EXPERIMENTAL CAPABILITIES
• Tank 200 Liters• Three-phase asynchronous motor 3KW• compressor single cylinder, swept volume 30 m3/h• The tank purge valve• measuring point at the air inlet (p1; T1)• measuring point at the outlet of the compressor (p2, T2)• measuring point at the outlet of the tank (p3, T3)• measuring point at the outlet of air (p4, T4)• diaphragms• operation and control of the casing• pressure switch• air filter• silencers• quarter-turn valve• needle valve of pressure adjusting with:
- differential pressure sensor - digital indicator: - electrical power consumption - pressure differential to the diaphragm
supply• 230 V mono phase - 50/60 hz
dimensions• LxWxh: 1800x750x2000 (mm)/Weight: 300kg
SERVICES REQUIREd
TEChNICAL dETAILS
test bench of aIr compressor
pcb 050
205
Thermodynamics compressor9
air filTer
measured air flow inTake for diaphragm and ma-nomeTer in u
air compressor• built according to ce standards• Two-stage• swept volume: 42 m3/h• power 4 kW• electric motor belt transmission• Tank capacity 270 liters
air exchanger - waTer firsT floor• part air equipped with a water separator and a tank• part water: exchange against the current
air exchanger - waTer second sTage • identical to the 1st stage
flow raTe measuremenT by diaphragms
insTrumenTaTion• Ten temperature sensors and digital display• five pressure sensors and manometers• four safety valves• a differential pressure manometer• four diaphragms• an air flowmeter• Two cooling water flowmeters• a wattmeter• a digital differential pressure sensor
TEChNICAL dETAILS
• study of a compressor• power• Yield• Work• flow rate• pressure• study of diaphragms• pressure-flow rate report
EXPERIMENTAL CAPABILITIES
supply• electricity : 400 Tri• Water network
dimensions• LxWxh: 300x300x300 (mm)/Weight: 9kg
SERVICES REQUIREd
two-staGe aIr compressor and dIaphraGm study
pcb 100
206
thermodynamics
fLu
ids
dYn
am
ics
mea
sure
men
TTh
erm
od
Yna
mic
spr
oc
ess
eng
inee
rin
gh
Ydra
uLic
spn
eum
aTic
seL
eVaT
ors
app
Lied
mec
ha
nic
s
pro
du
cTi
on
ac
TiVi
Ties
hVa
c a
nd
Th
erm
aL
eng
inee
rin
g
• study of a two-stage air compressor• overall yield, polytropic, isentropic and isothermal• influence of the rotational speed on the yield• heat balances on the intermediate exchangers• air flow rate measurement by a diaphragm
EXPERIMENTAL CAPABILITIES
air filTer
measuremenT of The inTake air flow raTe for The diaphragm and manomeTer in u
air compressor• Two-stage piston compressor• aspirated volume: 39 m3/h• maximum pressure: 10 bar• rotation speed 1290tr / min
elecTric engine• power: 4Kw• rotation speed: 3000tr / min• engine in balance for torque measurement• control of the speed of rotation by variator (1800 to 3000tr/ min)
exchanger air-waTer firsT sTage• Tubular exchanger cooled by water (exchange against the current)• Water separator with automatic air vent at the output
exchanger air-waTer second sTage• identical to that of the first stage
sTorage Tank of compressed air • accordance with the guidelines of pressurized equipment• 100L Volume• purge valve in the lower part and safety valve
measuremenT of The flow raTe of compressed air• automatic reducer for the output pressure regulation (3 bar)• float flowmeter• control valve at the output and exhaust silencer
insTrumenTaTion• Ten temperature sensors with a digital indicator• six pressure manometers• Three safety valves• a differential pressure manometer• a diaphragm• a float air flowmeter• Two cooling water flowmeters• a wattmeter• an engine rotational speed sensor with digital indicator• an engine torque sensor with digital indicator
TEChNICAL dETAILS
supply• electricity: 400Vac three phase + neutral + earth- 50hz-10a• Water : 10L/min-2bars
dimensions• LxWxh: 2000x800x1900 (mm)/Weight: 250kg
SERVICES REQUIREd
two-staGe aIr compressor
pcb 200
compressor9
Top Related