suntec technicalmanual
Dear Partner,
SUNTEC designs, manufactures and markets an unrivalled range of gear pumps and accessories. Thanks to its two production sites, one in the United States in Kentucky, the other in Europe, in France, in the heart of Burgundy, SUNTEC has an extensive network of customers and distributors.The quality, reliability and performance of its products have always enabled SUNTEC to offer innovative and pioneering products on the market.
This manual describes the operation and installation of SUNTEC low flow oil pumps. Conversion tables (replacement of models from other pump manufacturers by SUNTEC models), presentation of our AUV/ATUV Service pumps and a Frequently Asked Question section will give you answers to the questions you face about the maintenance and troubleshooting of your installations.
We hope this manual will help you in your daily service.
Your SUNTEC Team
1
TABLE OF CONTENTS1. Pump working principle ......................................................................................................................... 2
2. SUNTEC pump identification ............................................................................................................. 3
3. Conversion SUNTEC AE, AS, AL, ALE -> SUNTEC AUV ................................................ 6
4. Conversion SUNTEC AT2, ATE2 -> SUNTEC ATUV ......................................................... 16
5. Conversion DANFOSS -> SUNTEC ................................................................................................ 20
6. Conversion DELTA -> SUNTEC .......................................................................................................... 34
7. Conversion ECKERLE -> SUNTEC ................................................................................................... 38
8. Spare parts......................................................................................................................................................... 50
9. Connections ...................................................................................................................................................... 59
10. One-pipe↔two-pipeconfiguration ..................................................................................... 62
11. Pipe dimensions ........................................................................................................................................... 63
12. FAQs.......................................................................................................................................................................... 66
2
1. Pump working principle
1- Oilundersuctionfromtank2- Oil under pressure3- Oil pressure adjustment4- Delivery of oil under pressure to the nozzle5- Solenoidvalvecontrollingcut-offfunctiononnozzleline
Pressure adjustment
Solenoid valve
Shaftseal
Gear set
Return from tank
Inlet from tank
Oil under pressure
To nozzle
Oilundersuction
3
5
4
2
1
1
3
2. SUNTEC pump identification2.1 Choice of SUNTEC pump configuration (shaft rotation and nozzle outlet)
Notes :ThiscodificationisvalidforanySUNTECpumpexceptA2L,AUVandATUVpumps.ForA2L,theconfigurationisdeterminedbytheshaftrotationandthesidepressuregaugeportlocation.TA,TARandTpumpsexistonlyinAandCconfigurations.
A:Pumpseenfromshaftend, clockwiserotation, right hand nozzle outlet. Example:AL35A95266P0700
B :Pumpseenfromshaftend, clockwiserotation, lefthandnozzleoutlet. Example:AN67B13356P
C:Pumpseenfromshaftend, anti-clockwiserotation, lefthandnozzleoutlet. Example:AS47C15386P0700
D:Pumpseenfromshaftend, anti-clockwiserotation, right hand nozzle outlet. Example:AE47D13856P
2
4
R: Pumpseenfromshaftend clockwiserotation Example: -AUV47R98766P0700 -ATUV45R98616P0700
L: Pumpseenfromshaftend anti-clockwiserotation Example: -AUV47L98776P0700 -ATUV45L98606P0700
2.2 Choice of SUNTEC service pump configuration (shaft rotation) - AUV and ATUV models
2
5
2.3 Marking
Revisionnumber
Revisionnumber
Internal Code
Internal Code
Manufacturing dateDD/MM/YY
Manufacturing dateDD/MM/YYPump type
Pump type and modelnumber
Modelnumber
2
6
3. Conversion SUNTEC AE, AS, AL, ALE -> SUNTEC AUV
AE AUV RemarksAE35C9850xP AUV47L98776P0700 + Kit 991401
AE37C1376xP AUV47L98776P0700 + Kit 991401AE : pressure gauge port on the top of the body
AE45C1301xP AUV47L98776P0700 + Kit 991401
AE45C1360xP AUV47L98776P0700 + Kit 991401
AE45C1370xM AUV47L98776P0700+ Kit 991401+ G1/4 - G1/8 Adapters x2 (ref. 3729745)+ G1/8 - R1/8 connections (ref. 3723760)
AE45C1392xP AUV47L98776P0700 + Kit 991401+ G1/4-M14 connections (ref. 3759801)
AE45D1307xP AUV47L98776P0700 + Kit 991401
AE45D1308xP AUV47L98776P0700 + Kit 991401
AE47A1384xP AUV47R98766P0700 + Kit 991401
AE47B1366xP AUV47R98766P0700 + Kit 991401
→ The data given are also valid for one-pipe installations (AUV pumps are convertible into a one-pipe configuration).
3
7
AE AUV Remarks
AE47B7267xP AUV47R98766P0700AE : 2 pressure ports on the body + Kit 991401 + Hub adaptor Ø32-Ø54 (ref. 3759833)
AE47C1386xP AUV47L98776P0700 + Kit 991401AE pressure range : 2-12 bars
AE47C1387xP AUV47L98776P0700 + Kit 991401
AE47C1397xP AUV47L98776P0700 + Kit 991401
AE47C7274xM AUV47L98776P0700AE : 2 pressure ports on the body AUV to convert in one-pipe configuration+ Kit 991401 + Flange adaptor Ø32-Ø54 (ref. 3719003)
AE47C7368xP AUV47L98776P0700 AE : 2 pressure ports on the body + Kit 991401
AEV47C1394xP AUV47L98776P0700 + Kit 991401AE pressure range : 3-12 bars
AEV47C1398xM AUV47L98776P0700 + Kit 991401AE pressure range : 2-12 bars
AE47D1378xM AUV47L98776P0700 + Kit 991401AUV to convert in one-pipe configuration
AE47D1385xP AUV47L98776P0700 + Kit 991401
3
8
→ The data given in this table are valid for one-pipe installations (AUV pumps are convertible into a one-pipe configuration).
AS AUV RemarksAS47A1536xP0500/0700 AUV47R98766P0700
AS47A1589xP0500/0700 AUV47R98766P0700
AS47A1619xP0200 AUV47R98766P0700 Change the coil (24V AC ref. 3713823)
AS47A7432xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47A7436xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body + Hub adaptor Ø32-Ø54 (ref. 3759833)
AS47A7509xP0500/0700 AUV47R98766P0700AS : 2 pressure ports on the body Keep the AS pump nozzle connections+ G1/4 - G1/8 Adapters x2 (ref. 3729745)
AS47A7536xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body
AS47A7592xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body
AS47AK1564xP0500/0700 AUV47R98766P0700
AS47AK1602xP0500/0700 AUV47R98766P0700
AS47AK1612xM0500/0700 AUV47R98766P0700 AUV to convert in one-pipe configuration
AS47AK1613xP0500/0700 AUV47R98766P0700
AS47AK7469xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47AK7564xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body
3
9
AS AUV RemarksASV47A1636xP0500/0700 AUV47R98766P0700
ASV47A7472xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
ASV47AK7512xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body
AS47B1537xP0500/0700 AUV47R98766P0700
AS47B1616xP0500/0700 AUV47R98766P0700
AS47B7445xP0500/0700 AUV47R98766P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47B7470xP0500/0700 AUV47R98766P0700 AS : pressure port on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47BK1551xP0500/0700 AUV47R98766P0700
ASV47B1618xP0500/0700 AUV47R98766P0700
ASV47B1637xP0500/0700 AUV47R98766P0700
AS47C1538xP0500/0700 AUV47L98776P0700
AS47C1569xP0500/0700 AUV47L98776P0700
AS47C1578xP0500/0700 AUV47L98776P0700
AS47C1603xP0500/0700 AUV47L98776P0700
AS47C1604xP0500/0700 AUV47L98776P0700
3
10→ The data given are also valid for one-pipe installations (AUV pumps are convertible into a one-pipe configuration).
AS AUV RemarksAS47C1620xP0100/0600 AUV47L98776P0700 Change the coil (110V AC ref. 3713824)
AS47C1621xP0200 AUV47L98776P0700 Change the coil (24V AC ref. 3713823)
AS47C1625xP0500/0700 AUV47L98776P0700
AS47C7434xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47C7438xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body + Hub adaptor Ø32-Ø54 (ref. 3759833)
AS47C7444xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47C7461xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47C7538xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body
AS47C7541xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body
AS47CK1554xP0500/0700 AUV47L98776P0700
AS47CK1582xP0500/0700 AUV47L98776P0700 AS : horizontal pressure port on the body
AS47CK1623xP0500/0700 AUV47L98776P0700
AS47CK7451xM0500/0700 AUV47L98776P0700AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)AUV to convert in one-pipe configuration
ASV47C1627xP0500/0700 AUV47L98776P0700
3
11
AS AUV RemarksASV47C1638xP0500/0700 AUV47L98776P0700
ASV47CK1624xM0500/0700 AUV47L98776P0700 AUV to convert in one-pipe configuration
AS47D1539xP0500/0700 AUV47L98776P0700
AS47D1550xP0500/0700 AUV47L98776P0700
AS47D1557xP0500/0700 AUV47L98776P0700
AS47D1568xP0500/0700 AUV47L98776P0700 + G1/8 - M8 connections (ref. 3723838) + G1/4 - M14 connections (ref. 3759801)
AS47D1596xP0500/0700 AUV47L98776P0700
AS47D1615xP0500/0700 AUV47L98776P0700
AS47D7435xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body + Flange adaptor Ø32-Ø54 (ref. 3719003)
AS47D7439xP0500/0700 AUV47L98776P0700 AS : 2 pressure ports on the body + Hub adaptor Ø32-Ø54 (ref. 3759833)
AS47DK1562xP0500/0700 AUV47L98776P0700
AS47DK1573xM0500/0700 AUV47L98776P0700 AUV to convert in one-pipe configuration
AS47DK1586xP0500/0700 AUV47L98776P0700
AS47DK1597xP0500/0700 AUV47L98776P0700
ASV47D1640xP0200 AUV47L98776P0700 Change the coil (24V AC ref. 3713823)
3
12→ The data given are also valid for one-pipe installations (AUV pumps are convertible into a one-pipe configuration).
AL AUV RemarksASV47D1696xP0500/0700 AUV47L98776P0700
AL30C9518xP0500/0700 AUV47L98776P0700+ G1/4-M10 inlet connections (ref. 3723850)+ G1/4 - G1/8 return connection (ref. 3729745)+ G1/8 - M8 nozzle connection (ref. 3723838)
AL30C9535xP0500/0700 AUV47L98776P0700 + G1/8 - M8 connections (3723838)
AL30C9537xP0500/0700 AUV47L98776P0700 + G1/4-M10 connections (ref. 3723850)+ G1/8 - M8 connections (ref. 3723838)
AL30CK9516xP0500/0700 AUV47L98776P0700 + G1/4-M10 connections (ref. 3723850)+ G1/8 - M8 connections (ref. 3723838)
ALV30C9608xP0500/0700 AUV47L98776P0700 + G1/4-M10 connections (ref. 3723850)+ G1/8 - M8 connections (ref. 3723838)
ALV30C9611xP0500/0700 AUV47L98776P0700 + G1/4-M10 connections (ref. 3723850)+ G1/8 - M8 connections (ref. 3723838)
ALV30CK9612xP0500/0700 AUV47L98776P0700 + G1/4-M10 connections (ref. 3723850)+ G1/8 - M8 connections (ref. 3723838)
AL35A9501xP0100/0600 AUV47R98766P0700 Change the coil (110V AC ref. 3713824)
AL35A9526xP0500/0700 AUV47R98766P0700
AL35A9570xP0500/0700 AUV47R98766P0700 AL : side pressure port on the body on the nozzle side
AL35A9596xP0500/0700 AUV47R98766P0700 AL : pressure port on the body on the nozzle side
ALV35A9626xP0500/0700 AUV47R98766P0700
3
13
AL AUV RemarksAL35B9580xP0500/0700 AUV47R98766P0700 AL : 2 pressure ports on the body
AL35C9503xP0500/0700 AUV47L98776P0700
AL35C9514xP0100/0600 AUV47L98776P0700 Change the coil (110V AC ref. 3713824)
AL35C9519xP0500/0700 AUV47L98776P0700
AL35C9521xP0500/0700 AUV47L98776P0700
AL35C9528xP0500/0700 AUV47L98776P0700
AL35C9533xP0500/0700 AUV47L98776P0700
AL35C9540xP0500/0700 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
AL 35 C 9542 2P 25 AUV47L98776P0700
AL35C9545xP0500/0700 AUV47L98776P0700 + G1/8 - M8 connections (ref. 3723838)
AL35C9553xP0500/0700 AUV47L98776P0700
AL35C9578xP0500/0700 AUV47L98776P0700 AL : 2 pressure ports on the body
AL35CK9536xP0500/0700 AUV47L98776P0700 AL : 2 pressure ports on the body
ALV35C9573xP0500/0700 AUV47L98776P0700
ALV35C9614xP0100/0600 AUV47L98776P0700 Change the coil (110V AC ref. 3713824)
ALV35C9619xP0500/0700 AUV47L98776P0700
ALV35C9625xP0500/0700 AUV47L98776P0700 Keep the AL pump nozzle connections
3
14
AL AUV RemarksALV35C9628xP0500/0700 AUV47L98776P0700
AL35D9529xP0500/0700 AUV47L98776P0700
ALV35D9622xP0500/0700 AUV47L98776P0700
→ The data given are also valid for one-pipe installations (AUV pumps are convertible into a one-pipe configuration).
ALE AUV Remarks
ALE30C9336xP0500/0700 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)+ G1/8 - M8 connections (ref. 3723838)
ALEV30C9300xP0500/0700 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)+ G1/8 - M8 connections (ref. 3723838)
ALE35C9319xP0500/0700 AUV47L98776P0700
ALE35C9321xP0500/0700 AUV47L98776P0700
ALE35C9324xP0500/0700 AUV47L98776P0700
ALE35C9327xP0500/0700 AUV47L98776P0700 ALE : 2 pressure ports on the body
ALE35C9329xP0500/0700 AUV47L98776P0700
ALE35C9331xP0500/0700 AUV47L98776P0700
ALE35C9333xP0500/0700 AUV47L98776P0700
ALE35C9334xP0500/0700 AUV47L98776P0700 ALE : 2 pressure ports on the body
3
15
ALE AUV RemarksALE35CK9328xP0500/0700 AUV47L98776P0700 ALE : 2 pressure ports on the body
ALEV35C9317xP0500/0700 AUV47L98776P0700
ALEV35C9339xP0500/0700 AUV47L98776P0700
ALEV35C9356xP0500/0700 AUV47L98776P0700
ALEV35D9337xP0500/0700 AUV47L98776P0700
→ The data given are also valid for one-pipe installations (AUV pumps are convertible into a one-pipe configuration).
3
16
4. Conversion SUNTEC AT2, ATE2 -> SUNTEC ATUV
AT2 ATUV RemarksAT245A9547xP0500/0700 ATUV45R98616P0700
AT245A9574xP0500/0700 ATUV45R98616P0700
AT245AK9507xP0500/0700 ATUV45R98616P0700
AT2V45A9647xP0500/0700 ATUV45R98616P0700
AT245B9506xP0500/0700 ATUV45R98616P0700 + Flange adaptor Ø32-Ø54 (ref. 3719003)
AT245BK9601xP0500/0700 ATUV45R98616P0700
AT245BK9601xP0600 ATUV45R98616P0700 + Change the coils (ref. 3713824)
AT2V45B9651xP0500/0700 ATUV45R98616P0700
AT245C9541xP0500/0700 ATUV45L98606P0700
AT245C9543xP0600 ATUV45L98606P0700 + Change the coils (ref. 3713824)
AT245C9543xP0500/0700 ATUV45L98606P0700
AT245C9563xP0500/0700 ATUV45L98606P0700 + Nozzle fitting (ref. 3723838)+ Inlet and return fittings G1/4-G1/8 (ref. 3729745)
AT245C9594xP0500/0700 ATUV45L98606P0700
4
17
AT2 ATUV Remarks
AT2V45C9602xP0500/0700 ATUV45L98606P0700 + Nozzle fitting (ref. 3723838)+ Inlet and return fittings G1/4-G1/8 (ref. 3729745)
AT2V45C9604xP0500/0700 ATUV45L98606P0700
AT2V45C9616xP0500/0700 ATUV45L98606P0700
AT245D9513xP0500/0700 ATUV45L98606P0700 + Inlet/return and nozzle fittings from the old pump
AT245D9538xP0500/0700 ATUV45L98606P0700
AT245D9544xP0500/0700 ATUV45L98606P0700
AT245D9555xP0500/0700 ATUV45L98606P0700 + Inlet/return and nozzle fittings from the old pump
AT245D9584xP0500/0700 ATUV45L98606P0700
AT2V45D9603xP0500/0700 ATUV45L98606P0700
AT2V45D9615xP0500/0700 ATUV45L98606P0700 + Nozzle fitting (ref. 3723838)+ Inlet and return fittings G1/4-G1/8 (ref. 3729745)
AT2V45D9633xP0500/0700 ATUV45L98606P0700
AT2V45D9638xP0500/0700 ATUV45L98606P0700
AT255B9406xP0500/0700 ATUV45R98616P0700 + Flange adaptor Ø32-Ø54 (ref. 3719003)
AT255B9515xP0500/0700 ATUV45R98616P0700
4
18
AT2 ATUV Remarks
AT255C9504xP0500/0700 ATUV45L98606P0700
AT255C9549xP0500/0700 ATUV45L98606P0700
AT255C9572xP0500 ATUV45L98606P0700
AT255CK9571xP0500 ATUV45L98606P0700 + Nozzle fitting (ref. 3753948)
AT2V55C9672xP0500/0700 ATUV45L98606P0700
AT2V55CK9605xP0500/0700 ATUV45L98606P0700 + Nozzle fitting (ref. 3753948)
AT255C9572xP0500 ATUV45L98606P0700
AT255CK9571xP0500 ATUV45L98606P0700 + Nozzle fitting (ref. 3753948)
AT2V55C9672xP0500/0700 ATUV45L98606P0700
AT2V55CK9605xP0500/0700 ATUV45L98606P0700 + Nozzle fitting (ref. 3753948)
ATE2 ATUV Remarks
ATE2V45C9305xP0500/0700 ATUV45L98606P0700
ATE2V45C9306xP0500/0700 ATUV45L98606P0700
ATE2V45C9315xP0500/0700 ATUV45L98606P0700
4
19
ATE2 ATUV Remarks
ATE2V45C9355xP0500/0700 ATUV45L98606P0700
ATE255D9351xP0500/0700 ATUV45L98606P0700
ATE255D9353xP0500/0700 ATUV45L98606P0700
ATE2V55D9354xP0500/0700 ATUV45L98606P0700
4
20
5. Conversion DANFOSS -> SUNTEC
DANFOSS SUNTEC Remarks
BFP10L6071N0272 AE57C73734P
BFP10L6071N0276 AE57C73734P AE to convert in one-pipe configuration
BFP10L8071N6111 AE67C73614P
BFP10L11071N6107 AE77C73802P
BFP10L13071N6103 AE97C73902P + Kit 991492
BFP10R3071N0177 AUV47R98766P0700+Kit991401
BFP10R3071N0288 AUV47R98766P0700+Kit991401 AUV to convert in one-pipe configuration
BFP10R5071N0166 AUV47R98766P0700+Kit991401
BFP10R6071N0273 ANV57A73594P AN: Hydraulic cut-off, 14 bars max.
BFP10R6071N0277 ANV57A73594P AN: Hydraulic cut-off, 14 bars max., to convert in one-pipe configuration
BFP10R8071N6112 AN67A73454P AN: Hydraulic cut-off
BFP10R11071N6108 AN77A73462P AN: Hydraulic cut-off
BFP10R13071N6104 AN97A73912P AN: Hydraulic cut-off
BFP11L3071N0101 AUV47L98776P0700
BFP11L3071N0114 AUV47L98776P0700
5
21
DANFOSS SUNTEC Remarks
BFP11L3071N0141 AUV47L98776P0700 AUV to convert in one-pipe configuration
BFP11L3071N0142 AUV47L98776P0700 AUV to convert in one-pipe configuration
BFP11L3071N0144 AUV47L98776P0700
BFP11L3071N0146 AUV47L98776P0700
BFP11L3071N0152 AUV47L98776P0700
BFP11L3071N0153 AUV47L98776P0700 AUV: Change the coil (24V ref. 3713823)
BFP11L3071N0184 AUV47L98776P0700
BFP11L3071N0210 AUV47L98776P0700
BFP11L3071N0213 AUV47L98776P0700
BFP11L3071N7141 AUV47L98776P0700
BFP11L5071N0105 AUV47L98776P0700
BFP11L5071N0178 AUV47L98776P0700
BFP11L6071N1270 AS57C15836P0700 AS: 14 bars max.
BFP11L6071N1274 AS57C15836P0700 AS: 14 bars max., to convert in one-pipe configuration
BFP11L8071N6109 AL65C95896P0700 AL: 15 bars max.
BFP11R3071N0143 AUV47R98766P0700
BFP11R3071N0145 AUV47R98766P0700
5
22
DANFOSS SUNTEC Remarks
BFP11R3071N0155 AUV47R98766P0700
BFP11R3071N0181 AUV47R98766P0700
BFP11R3071N0183 AUV47R98766P0700
BFP11R3071N7155 AUV47R98766P0700
BFP11R6071N0271 AS57A75914P0700
BFP11R6071N0275 AS57A75914P0700 AS to convert in one-pipe configuration
BFP11R6071N1271 AS57A75914P0700 AS: 14 bars max.
BFP11R6071N1275 AS57A75914P0700 AS: 14 bars max., to convert in one-pipe configuration
BFP11R8071N6110 AL65B95326P0700
BFP11R11071N6106 AL75B95396P0700 AL: 15 bars max. and left nozzle outlet
BFP12L6071N6217 A2L65CK97044P0700
BFP12L8071N6210 A2L65CK97044P0700
BFP12L11071N6202 A2L75CK97014P0700
BFP12L13071N6203 A2L95D97024P0700
BFP12R6071N6218 A2L65A97084P0700
BFP12R8071N6219 A2L65A97084P0700
BFP12R11071N6214 A2L95B97114P0700
5
23
DANFOSS SUNTEC Remarks
BFP12R13071N6220 A2L95B97114P0700
BFP20L3071N0108 AUV47L98776P0700+Kit991401
BFP20L3071N0125 AUV47L98776P0700+Kit991401
BFP20L3071N0127 AUV47L98776P0700+Kit991401
BFP20L3071N0161 AUV47L98776P0700+Kit991401
BFP20L3071N0212 AUV47L98776P0700+Kit991401
BFP20L3071N0267 AUV47L98776P0700+Kit991401
BFP20L5071N0126 AUV47L98776P0700+Kit991401
BFP20R3071N0118 AUV47R98766P0700+Kit991401
BFP20R3071N0128 AUV47R98766P0700+Kit991401
BFP20R3071N0162 AUV47R98766P0700+Kit991401
BFP20R3071N0169 AUV47R98766P0700+Kit991401
BFP20R3071N0229 AUV47R98766P0700+Kit991401
BFP20R3071N0298 AUV47R98766P0700+Kit991401 AUV to convert in one-pipe configuration
BFP20R5071N0129 AUV47R98766P0700+Kit991401
BFP20R5071N0180 AUV47R98766P0700+Kit991401
BFP21L2071N2123 AUV47L98776P0700
5
24
DANFOSS SUNTEC Remarks
BFP21L3071N0102 AUV47L98776P0700
BFP21L3071N0103 AUV47L98776P0700
BFP21L3071N0104 AUV47L98776P0700
BFP21L3071N0111 AUV47L98776P0700
BFP21L3071N0113 AUV47L98776P0700
BFP21L3071N0119 AUV47L98776P0700
BFP21L3071N0122 AUV47L98776P0700
BFP21L3071N0123 AUV47L98776P0700 AUV: Change the coil (110V ref. 3713824)
BFP21L3071N0130 AUV47L98776P0700
BFP21L3071N0132 AUV47L98776P0700
BFP21L3071N0147 AUV47L98776P0700
BFP21L3071N0148 AUV47L98776P0700
BFP21L3071N0150 AUV47L98776P0700
BFP21L3071N0151 AUV47L98776P0700
BFP21L3071N0156 AUV47L98776P0700 AUV to convert in one-pipe configuration
BFP21L3071N0164 AUV47L98776P0700
BFP21L3071N0170 AUV47L98776P0700
5
25
DANFOSS SUNTEC Remarks
BFP21L3071N0175 AUV47L98776P0700
BFP21L3071N0176 AUV47L98776P0700 AUV: Change the coil (110V ref. 3713824)
BFP21L3071N0179 AUV47L98776P0700
BFP21L3071N0182 AUV47L98776P0700
BFP21L3071N0185 AUV47L98776P0700
BFP21L3071N0189 AUV47L98776P0700 AUV: Change the coil (24V ref. 3713823)
BFP21L3071N0193 AUV47L98776P0700
BFP21L3071N0197 AUV47L98776P0700
BFP21L3071N0204 AUV47L98776P0700
BFP21L3071N0209 AUV47L98776P0700
BFP21L3071N0217 AUV47L98776P0700
BFP21L3071N0226 AUV47L98776P0700
BFP21L3071N0228 AUV47L98776P0700
BFP21L3071N0295 AUV47L98776P0700
BFP21L3071N1214 AUV47L98776P0700 AUV to convert in one-pipe configuration
BFP21L3071N1217 AUV47L98776P0700
BFP21L3071N1219 AUV47L98776P0700
5
26
DANFOSS SUNTEC Remarks
BFP21L3071N7170 AUV47L98776P0700
BFP21L3L2071N2130 AUV47L98776P0700
BFP21L3LE071N2103 AUV47L98776P0700
BFP21L3LE071N2104 AUV47L98776P0700
BFP21L3LE071N2108 AUV47L98776P0700
BFP21L3LE071N2110 AUV47L98776P0700
BFP21L3LE071N2112 AUV47L98776P0700
BFP21L3LE071N2113 AUV47L98776P0700
BFP21L3LE071N2114 AUV47L98776P0700
BFP21L3LE071N2118 AUV47L98776P0700
BFP21L3LE071N2119 AUV47L98776P0700
BFP21L3LE071N3118 AUV47L98776P0700
BFP21L3LE071N3119 AUV47L98776P0700
BFP21L3LE071N4105 AUV47L98776P0700
BFP21L3LE-S071N0233 AUV47L98776P0700
BFP21L3LE-S071N0264 AUV47L98776P0700
BFP21L3LE-S071N2116 AUV47L98776P0700
5
27
DANFOSS SUNTEC Remarks
BFP21L3LE-S071N2125 AUV47L98776P0700
BFP21L3LE-S071N2128 AUV47L98776P0700
BFP21L3LE-S071N2225 AUV47L98776P0700
BFP21L3LE-S071N2303 AUV47L98776P0700
BFP21L3LE-S071N3136 AUV47L98776P0700
BFP21L3LE-S071N3225 AUV47L98776P0700
BFP21L5071N0107 AUV47L98776P0700
BFP21L5071N0116 AUV47L98776P0700
BFP21L5071N0158 AUV47L98776P0700
BFP21L5071N0172 AUV47L98776P0700
BFP21L5071N0194 AUV47L98776P0700
BFP21L5071N0202 AUV47L98776P0700
BFP21L5071N0227 AUV47L98776P0700
BFP21L5071N0292 AUV47L98776P0700
BFP21L5071N7172 AUV47L98776P0700
BFP21L5LE-S071N2131 AUV47L98776P0700
BFP21R3071N0109 AUV47R98766P0700
5
28
DANFOSS SUNTEC Remarks
BFP21R3071N0112 AUV47R98766P0700
BFP21R3071N0136 AUV47R98766P0700
BFP21R3071N0154 AUV47R98766P0700
BFP21R3071N0157 AUV47R98766P0700 AUV to convert in one-pipe configuration
BFP21R3071N0167 AUV47R98766P0700
BFP21R3071N0171 AUV47R98766P0700
BFP21R3071N0198 AUV47R98766P0700
BFP21R3071N0208 AUV47R98766P0700
BFP21R3071N0214 AUV47R98766P0700
BFP21R3071N0215 AUV47R98766P0700
BFP21R3071N0231 AUV47R98766P0700 AUV to convert in one-pipe configuration
BFP21R3071N1215 AUV47R98766P0700 AUV to convert in one-pipe configuration
BFP21R3071N7171 AUV47R98766P0700
BFP21R5071N0120 AUV47R98766P0700
BFP21R5071N0159 AUV47R98766P0700
BFP21R5071N0163 AUV47R98766P0700
BFP21R5071N0165 AUV47R98766P0700
5
29
DANFOSS SUNTEC Remarks
BFP21R5071N0173 AUV47R98766P0700
BFP21R5071N0195 AUV47R98766P0700
BFP21R5071N0207 AUV47R98766P0700
BFP21R5071N7173 AUV47R98766P0700
BFP31L3071N0115 AUV47L98776P0700
BFP31L3071N0133 AUV47L98776P0700 AUV to convert in one-pipe configuration
BFP31L3071N0149 AUV47L98776P0700
BFP31L3071N0190 AUV47L98776P0700
BFP31L3071N0191 AUV47L98776P0700
BFP31L3071N0192 AUV47L98776P0700
BFP31L3071N1201 AUV47L98776P0700
BFP31L3071N1203 AUV47L98776P0700
BFP31L3LE071N2109 AUV47L98776P0700
BFP41L3071N0135 AUV47L98776P0700
BFP41L3071N0160 AUV47L98776P0700 AUV: Coil on top
BFP41L3071N0174 AUV47L98776P0700 AUV: Coil on top
BFP41L3071N0188 AUV47L98776P0700 AUV: Coil on top
5
30
DANFOSS SUNTEC Remarks
BFP41L3071N0224 AUV47L98776P0700 AUV: Coil on top
BFP41L3071N0225 AUV47L98776P0700 AUV: Coil on top
BFP41L3071N1213 AUV47L98776P0700 AUV: Coil on top
BFP41L3071N7174 AUV47L98776P0700 AUV: Coil on top
BFP41L3LE-S071N3137 AUV47L98776P0700 AUV: Coil on top
BFP41R3071N0137/138 AUV47R98766P0700 AUV: Coil on top
BFP41R3071N0196 AUV47R98766P0700 AUV: Coil on top
BFP41R3071N0235 AUV47R98766P0700 AUV: Coil on top
BFP41R3071N7137 AUV47R98766P0700 AUV: Coil on top
BFP51L6071N6204 AP265C95114P0700
BFP51L8071N6222 AP265C95114P0700
BFP51L11071N6205 AP295C95904P0700
BFP51L13071N6225 AP295C95904P0700
BFP51R6071N6221 AP265B95234P0700
BFP51R8071N6223 AP265B95234P0700
BFP52L6071N6206 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52: P1=7-15 bars
BFP52L8071N6207 AT265C95564P0700
5
31
DANFOSS SUNTEC Remarks
BFP52L11071N6209 AT275C95834P0700
BFP52L13071N6211 AT295C95854P0700
BFP52R6071N6227 ATUV45R98616P0700ATUV: P1=2-12 bars, nozzle= up to 3 GPH @1,8 cSt & 5 GPH @5 cStBFP52: P1=7-15 bars
BFP52R8071N6208 AT265B95874P0700
BFP52R11071N6210 AT275B95914P0700
BFP52R13071N6212 AT295B95924P0700
BFP52EL3071N2201 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3071N2209 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3071N2211 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3071N2213 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3071N2264 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3071N3201 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3LE-S071N2222 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
5
32
DANFOSS SUNTEC Remarks
BFP52EL3LE-S071N3213 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3LE-S071N3214 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3LE-S071N3215 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL3LE-S071N4222 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL5071N2202 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL5071N2205 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL5071N2212 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL5071N2217 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL5071N2220 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL5071N2265 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52EL5071N3202 ATUV45L98606P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
5
33
DANFOSS SUNTEC Remarks
BFP52ER3071N2203 ATUV45R98616P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52ER3071N3203 ATUV45R98616P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52ER5071N2204 ATUV45R98616P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP52ER5071N3204 ATUV45R98616P0700 ATUV: P1=2-12 barsBFP52E: P1=7-15 bars
BFP53L6071N6213 AT355C95504P0700
BFP53L8071N6229 AT365C95614P0700
5
34
6. Conversion DELTA -> SUNTEC
DELTA SUNTEC Remarks
A1-L1 AUV47L98776P0700 AUV to convert in one-pipe configuration
A1-L2 AUV47L98776P0700
A1-R1 AUV47R98766P0700 AUV to convert in one-pipe configuration
A1-R2 AUV47R98766P0700
A2-L1 AUV47L98776P0700 AUV to convert in one-pipe configuration
A2-L2 AUV47L98776P0700
A2-R1 AUV47R98766P0700 AUV to convert in one-pipe configuration
A2-R2 AUV47R98766P0700
AD1-L1 AN47C13426PAN47D13396P
AN : Left nozzle outlet*, to convert in one-pipe configurationAN : Right nozzle outlet*, to convert in one-pipe configuration
AD1-L2 AN47C13426PAN47D13396P
AN : Left nozzle outlet*AN : Right nozzle outlet*
AD1-R1 AN47A13266PAN47B13956P
AN : Right nozzle outlet*, to convert in one-pipe configurationAN : Left nozzle outlet*, to convert in one-pipe configuration
AD1-R2 AN47A13266PAN47B13956P
AN : Right nozzle outlet*AN : Left nozzle outlet*
AD2-L1 AN57C73494PAN57DK13036P
AN : Left nozzle outlet*, to convert in one-pipe configurationAN : Right nozzle outlet*, to convert in one-pipe configuration
6*Seenfromshaftend.
35
DELTA SUNTEC Remarks
AD2-L2 AN57C73494PAN57DK13036P
AN : Left nozzle outlet*AN : Right nozzle outlet*
AD2-R1 ANV57A73594PAN57B13306P
AN : Right nozzle outlet*, to convert in one-pipe configurationAN : Left nozzle outlet*, to convert in one-pipe configuration
AD2-R2 ANV57A73594PAN57B13306P
AN : Right nozzle outlet*AN : Left nozzle outlet*
V1LL1 AN47D13396P AUV to convert in one-pipe configuration
V1LL2 AN47D13396P
V1LR1 AN47C13426P AUV to convert in one-pipe configuration
V1LR2 AN47C13426P
V1RL1 AN47A13266P AUV to convert in one-pipe configuration
V1RL2 AN47A13266P
V1RR1 AN47B13956P AUV to convert in one-pipe configuration
V1RR2 AN47B13956P
V2LL1 AN57D13036P AUV to convert in one-pipe configuration
V2LL2 AN57D13036P
V2LR1 AN57C73494P AUV to convert in one-pipe configuration
V2LR2 AN57C73494P
V2RL1 ANV57A73594P AUV to convert in one-pipe configuration
6
36*Seenfromshaftend.
DELTA SUNTEC Remarks
V2RL2 ANV57A73594P
V2RR1 AN57B13306P AUV to convert in one-pipe configuration
V2RR2 AN57B13306P
VD1LL1 AN47D13396P AUV to convert in one-pipe configuration
VD1LL2 AN47D13396P
VD1LR1 AN47C13426P AUV to convert in one-pipe configuration
VD1LR2 AN47C13426P
VD1RL1 AN47A13266P AUV to convert in one-pipe configuration
VD1RL2 AN47A13266P
VD1RR1 AN47B13956P AUV to convert in one-pipe configuration
VD1RR2 AN47B13956P
VD2LR1 AN57C73494P AUV to convert in one-pipe configuration
VD2LR2 AN57C73494P
VD2LL2 AN57D13036P
VD2RL1 ANV57A73594P AUV to convert in one-pipe configuration
VD2RL2 ANV57A73594P
VD2RR1 AN57B13306P AUV to convert in one-pipe configuration
6
37*Seenfromshaftend.
DELTA SUNTEC Remarks
VD2RR2 AN57B13306P
VM1LL1 AUV47L98776P0700 AUV to convert in one-pipe configuration
VM1LL2 AUV47L98776P0700
VM1LR1 AUV47L98776P0700 AUV to convert in one-pipe configuration
VM1LR2 AUV47L98776P0700
VM1RL1 AUV47R98766P0700 AUV to convert in one-pipe configuration
VM1RL2 AUV47R98766P0700
VM1RR1 AUV47R98766P0700 AUV to convert in one-pipe configuration
VM1RR2 AUV47R98766P0700
VM2LL1 AUV47L98776P0700 AUV to convert in one-pipe configuration
VM2LL2 AUV47L98776P0700
VM2LR1 AUV47L98776P0700 AUV to convert in one-pipe configuration
VM2LR2 AUV47L98776P0700
VM2RL1 AUV47R98766P0700 AUV to convert in one-pipe configuration
VM2RL2 AUV47R98766P0700
VM2RR1 AUV47R98766P0700 AUV to convert in one-pipe configuration
VM2RR2 AUV47R98766P0700
6
38
7. Conversion ECKERLE -> SUNTEC
ECKERLE SUNTEC Remarks
UNI 1.1 L5 L64 -10 AN47C13426P + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 1.1 L5 L64-M1 AN47C13426P + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 1.2 L1 L64-50 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 1.2 L5 L14-50 AUV47L98776P0700
UNI 1.2 L5 M14-50 AUV47L98776P0700
UNI 1.2 L5 M64-50-W AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 1.2 L62 M14-01-W AL65C95896P0700
UNI 1.42 L6 A64-W ATUV45L98606P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI1.72L62L14-W AL75CK95346P0700
UNI 2.1 G22 L1 L10 AN47C13426P AN: Shaft with one flat (1), no top pressure gauge port
UNI 2.1 G41-21 L1 L10 AN47C13426P AN: Shaft with one flat (1)
UNI 2.1 L1 L44-21 AN47C13426P
UNI 2.1 L1 L44-H1-21 AN47C13426P AN: Shaft with one flat (1),no top pressure gauge port
7
(1)ECKERLEmodelwith2flatsontheshaft;changecoupling.
39
ECKERLE SUNTEC Remarks
UNI 2.1 L5 L40-21 AN47C13426P AN: Shaft with one flat (1)
UNI 2.1 L5 L42-21 AN47C73424P AN: Shaft with one flat (1) + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI 2.1 L5 L44-21-05 AN47C13426P
UNI 2.1 L5 R44-21 AN47D13396P
UNI 2.1 L5 R94-05 AN47D13396P + G1/4 - G1/8 Adapters x2 (ref. 3729745)AN: Pressure range 7 - 14 bars
UNI 2.1 L6 L54-05 AN67C13366P AN: Pressure range 7 - 14 bars
UNI 2.1 R1 L40 AN47B73274P AN: Shaft with one flat (1)
UNI 2.1 R1 L44-21 AN47B73274P
UNI 2.1 R5 L42-UI-21 AN47B73274P AN: Shaft with one flat (1) + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI 2.1 R5 L43-UI-21 AN47B73274P AN: Shaft with one flat (1) + Flange adaptor Ø32-Ø54 (Ref. 3719003)
UNI 2.1 R5 L44-21 AN47B73274P
UNI 2.1 R5 L54 AN47B13956P
UNI 2.1 R5 R44-21-05 AN47A13266P
7
40(1)ECKERLEmodelwith2flatsontheshaft;changecoupling.
ECKERLE SUNTEC Remarks
UNI 2.1 R5 R45-21 AN47A72264P
UNI 2.1 R5 R80-05 AN47A13266P AN: Shaft with one flat (1),+ G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.1 R6 L25 AN67B72874P
UNI 2.1 R6 L54-05 AN67B13356P
UNI 2.12 L1 L14 AUV47L98776P0700
UNI 2.12 L1 L64 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.12 L1 M14 AUV47L98776P0700
UNI 2.12 L1 M64 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.12 L1 M64-65 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.12 L6 M14 AL65C95896P0700
UNI 2.12 L6 M14-65 AL65C95896P0700
UNI2.17L6M14-65 AL75CK95346P0700
UNI 2.2 L1 L14-21 AUV47L98776P0700
UNI 2.2 L1 L16-K1-21 AUV47L98776P0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)
UNI 2.2 L1 R14-C1-21 AUV47L98776P0700
7
41
ECKERLE SUNTEC Remarks
UNI 2.2 L5 L14-21-05 AUV47L98776P0700
UNI 2.2 L5 L14-Q-21 AUV47L98776P0700
UNI 2.2 L5 L15-21-05 AUV47L98776P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI 2.2 L5 L42 AUV47L98776P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI 2.2 L5 M14-C1 AUV47L98776P0700
UNI 2.2 L5 S20-21 AUV47L98776P0700
UNI2.2L5S20-21-BUD AUV47L98776P0700
UNI2.2L5S74-05 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.2 L6 L16-K1 AS67C74564P0700 AS: pressure range 10 - 15 bars
UNI 2.2 L6 L24-05 AS67C15706P0700 AS: pressure range 10 - 15 bars
UNI 2.2 R1 L40 AUV47R98766P0700
UNI 2.2 R1 M14-21-05 AUV47R98766P0700
UNI 2.2 R1 R24 AUV47R98766P0700
UNI 2.2 R5 L14-21-05 AUV47R98766P0700
UNI 2.2 R5 M45 AUV47R98766P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
7
42
ECKERLE SUNTEC Remarks
UNI 2.2 R5 R14-21 AUV47R98766P0700
UNI 2.2 R5 R60-21 AUV47R98766P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.2 R5 S60 AUV47R98766P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.2 R6 M24-05 AS67B15756P0700 AS: pressure range 10 - 15 bars
UNI 2.3 L1 L56-I D45C73893PF
UNI 2.3 L5 L54-S-05 D45C73743P
UNI 2.3 L5 L56-I D45C73893PF
UNI 2.3 R5 L54-05 D45B73473P
UNI 2.3 R5 R54-L D47A73833P
UNI 2.4 L1 M10-V2 AP47C75564P0700 AP: Shaft with one flat (1)
UNI 2.4 L1 M14-C1 AP47C75564P0700
UNI 2.4 L1 R14-C1-21 AP245D95664P0700
UNI 2.4 L1 R44 AP245D95664P0700
UNI 2.4 L5 L24 AP47C75564P0700
UNI 2.4 L5 M24 AP47C75564P0700
(1)ECKERLEmodelwith2flatsontheshaft;changecoupling.
7
43
ECKERLE SUNTEC Remarks
UNI 2.4 L5 M20-21 AP245C95694P0700
UNI 2.4 L5 S24 ATUV45L98606P0700
UNI 2.4 L6 L24-05 AP67C75594P0700
UNI 2.4 L6 M24-C1 AP67C75594P0700
UNI2.4L7L24-05 AP295C95904P0700
UNI2.4L7L56 AP295C95904P0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)
UNI2.4L7M25 AP295C95904P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI2.4R5S70-ET AP47A15934P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.4 R6 S24-ET AP67A15946P0700
UNI 2.42 L5 L64-65 ATUV45L98606P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI2.42R5R70 ATUV45R98616P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI2.42R5R70-ET ATUV45R98616P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI 2.6 L6 L44 AN67C13366P AN to convert in one-pipe operation
UNI2.91L7L44-05 AE97C73902P
UNI 2.96 L5 L44-05 AN47C13426P + Low pressure kit 991500
7
44
ECKERLE SUNTEC Remarks
UNI-E 2.1 G22 AN47C13426P AN: Shaft with one flat (1),no top pressure gauge port
UNI-E 2.1 G41 AN47C13426P AN: Shaft with one flat (1)
UNI-E2.1 G41-13 AUV47L98776P0700 + Kit 991401
UNI-E 2.1 L1 L10 AN47C13426P AN: Shaft with one flat (1)
UNI-E 2.1 L1 L10-22 AN47C13426P AN: Shaft with one flat (1)
UNI-E 2.1 L1 L10-30 AN47C13426P AN: Shaft with one flat (1),no top pressure gauge port
UNI-E 2.1 L1 L14 AN47C13426P
UNI-E 2.1 L1 L64 AN47C13426P + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.1 L1 L64-21 AN47C13426P + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.1 L5 L10 AN47C13426P AN: Shaft with one flat (1)
UNI-E 2.1 L5 L12 AN47C73424P AN: Shaft with one flat (1) + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI-E 2.1 L5 L14 AN47C13426P
UNI-E 2.1 L5 L14-13 AUV47L98776P0700 + Kit 991401
UNI-E 2.1 L5 R14 AN47D13396P
(1)ECKERLEmodelwith2flatsontheshaft;changecoupling.
7
45
ECKERLE SUNTEC Remarks
UNI-E 2.1 L5 R14-13 AUV47L98776P0700 + Kit 991401
UNI-E2.1L5R74 AN47D13396P + G1/4 - G1/8 Adapters x2 (ref. 3729745)AN: Pressure range 7 - 14 bars
UNI-E 2.1 L6 L16-11 AE67C72854P
UNI-E 2.1 L6 L24 AN67C13366P AN: Pressure range 7 - 14 bars
UNI-E 2.1 R1 L10 AN47B73274P AN: Shaft with one flat (1)
UNI-E 2.1 R1 L14 AN47B73274P
UNI-E 2.1 R5 L12-80 AN47B73274P AN: Shaft with one flat (1) + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI-E 2.1 R5 L13-80 AN47B73274P AN: Shaft with one flat (1) + Flange adaptor Ø32-Ø54 (Ref. 3719003)
UNI-E 2.1 R5 L14 AN47B73274P
UNI-E 2.1 R5 L24 AN47B13956P
UNI-E 2.1 R5 R14 AN47A13266P
UNI-E 2.1 R5 R15 AN47A72264P
UNI-E 2.1 R5 R60 AN47A13266P AN: Shaft with one flat (1)+ G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.1 R6 L24 AN67B13356P
7
46
ECKERLE SUNTEC Remarks
UNI-E 2.1 R6 L25 AN67B72874P
UNI-E 2.2 L1 L10 AUV47L98776P0700
UNI-E 2.2 L1 L14 AUV47L98776P0700
UNI-E 2.2 L1 L16-10 AUV47L98776P0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)
UNI-E 2.2 L1 R14-12 AUV47L98776P0700
UNI-E 2.2 L5 L12 AUV47L98776P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI-E 2.2 L5 L14 AUV47L98776P0700
UNI-E 2.2 L5 L14-92 AUV47L98776P0700
UNI-E 2.2 L5 L15 AUV47L98776P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI-E 2.2 L5 L60 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.2 L5 M14-12 AUV47L98776P0700
UNI-E 2.2 L5 S20 AUV47L98776P0700
UNI-E2.2L5S20-BUD AUV47L98776P0700
UNI-E2.2L5S74 AUV47L98776P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.2 L6 L14 AS67C15706P0700 AS: Pressure range 10 - 15 bars
(1)ECKERLEmodelwith2flatsontheshaft;changecoupling.
7
47
ECKERLE SUNTEC Remarks
UNI-E 2.2 L6 L16-10 AS67C74564P0700 AS: pressure range 10 - 15 bars
UNI-E 2.2 L6 L24 AS67C15706P0700 AS: pressure range 10 - 15 bars
UNI-E 2.2 L6 LR14-61 A2L65D97034P0700
UNI-E2.2L7L26 AL95C94124P0700
UNI-E2.2L7LR14-61 A2L95D97024P0700
UNI-E 2.2 R1 L10 AUV47R98766P0700
UNI-E 2.2 R1 M14 AUV47R98766P0700
UNI-E 2.2 R1 R24 AUV47R98766P0700
UNI-E 2.2 R1 S14 AUV47R98766P0700
UNI-E 2.2 R5 L14 AUV47R98766P0700
UNI-E 2.2 R5 M14 AUV47R98766P0700
UNI-E 2.2 R5 M15 AUV47R98766P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI-E 2.2 R5 R14 AUV47R98766P0700
UNI-E 2.2 R5 R60 AUV47R98766P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.2 R5 S14 AUV47R98766P0700
7
48
ECKERLE SUNTEC Remarks
UNI-E 2.2 R5 S60 AUV47R98766P0700 + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.2 R6 M24 AS67B15756P0700 AS: pressure range 10 - 15 bars
UNI-E 2.3 L1 L26-80 D45C73893PF
UNI-E 2.3 L5 L24-13 D45C73743P
UNI-E 2.3 L5 L26-80 D45C73893PF
UNI-E 2.3 L5 L64 D45C73743P + G1/4 - G1/8 Adapters x2 (ref. 3729745)
UNI-E 2.3 R5 L24 D45B73473P
UNI-E 2.3 R5 R24-93 D47A73833P
UNI-E 2.4 L1 M10-22 AP47C75564P0700 AP: Shaft with one flat (1)
UNI-E 2.4 L1 M14-12 AP47C75564P0700
UNI-E 2.4 L1 R14 AP245D95664P0700
UNI-E 2.4 L1 R14-12 AP245D95664P0700
UNI-E 2.4 L5 L20 AP245C95694P0700
UNI-E 2.4 L5 L24 AP47C75564P0700
UNI-E 2.4 L5 M20 AP245C95694P0700
UNI-E 2.4 L5 M24 AP47C75564P0700
UNI-E 2.4 L5 S24 ATUV45L98606P0700
(1)ECKERLEmodelwith2flatsontheshaft;changecoupling.
7
49
ECKERLE SUNTEC Remarks
UNI-E 2.4 L6 L24 AP67C75594P0700
UNI-E 2.4 L6 M24-12 AP67C75594P0700
UNI-E2.4L7L22 AP295C95904P0700 AP2: Shaft with one flat (1)+ Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI-E2.4L7L24 AP295C95904P0700
UNI-E2.4L7L26 AP295C95904P0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)
UNI-E2.4L7L26-05 AP295C95904P0700 + Flange adaptor Ø32-Ø54 (Ref. 3719003)
UNI-E2.4L7M25 AP295C95904P0700 + Hub adaptor Ø32-Ø54 (Ref. 3759833)
UNI-E2.4R5S70 AP47A15934P0700
UNI-E 2.4 R6 S24 AP67A15946P0700
UNI-E2.42R5R70 ATUV45R98616P0700
UNI-E 2.6 L5 L14 AN47C13426P AN to convert in one-pipe operation
UNI-E 2.6 L6 L14 AN67C13366P AN to convert in one-pipe operation
UNI-E2.91 L5 L14 AN47C13426P + Low pressure kit 991500
UNI-E2.91L7L14 AE97C73902P
UNI-E 2.96 L5 L14 AN47C13426P + Low pressure kit 991500
(1)ECKERLEmodelwith2flatsontheshaft;changecoupling.
7
50
8. Spare parts
1
6
8
7
2
3
4 5
1 Shaftseal2 By-passplug3 G 1/4 steel plug4 Filter5 Cover gasket6 Coil7 Solenoidtube8 Solenoid valve
8
51
Description Pump type Reference
Shaft seal (1) AN, AE, AS, AL, ALE, AUV, A2L, AR, AP, AT, ATUV 991552
By-pass plug (2) AN, AE, AS, AL, ALE, AUV, A2L, AR, AP, AT 3779858
Plug (3)
AN, AE, AS, AL, ALE, AUV, A2L, AR, AP, ATG 1/4 steel plug 3779191
AN, AE, AS, AL, ALE, AUV, A2L, AR, AP, AT, ATUVG 1/8 steel plug 3779835
Coil (6)
AS, AL, ALE, AUV, A2L, AR, AP, AT, ATUV220-240V;50/60Hz 3713871SAV
AS, AL, ALE, AUV, A2L, AR, AP, AT, ATUV110-120V;50/60Hz 3713824
AS, AL, ALE, AUV, A2L, AR, AP, AT, ATUV24V;50/60Hz 3713823
8
52
Description Pump type Reference
Filter (4)
AN, AE, AS, AP 47/57/67Series7000-Rev.3,4,5,6Series 1000 - Rev. 1, 4, 5, 6
991530 (Height 20 mm)
AN, AE, AS, AP 47/57/67Series7000-Rev.2
3715732(Height28mm)(onlyforpumpsmanufacturedafter1988)
AN, AE 77/97Series7000-Rev.3,4Series 1000 - Rev. 1, 6
3715750(Height23mm)
AN, AE 77/97Series7000-Rev.2
3715732(Height28mm)(onlyforpumpsmanufacturedafter1988)
AL, ALE, A2L, AR 35/55/65991530 (Height 20 mm)
AP2, AP3, AT2, AT3 45/55/65
AL, ALE, A2L, AR 75/953715750(Height23mm)
AP2, AT2 75/95
AUV, ATUV 991530 (Height 20 mm)
8
53
Description Pump type Reference
Cover gasket (5)
AN, AE, AS, AP 47/57/67/77/97Series7000-Rev.4,6Series 1000 - Rev. 4, 6
991524
AN, AE, AS, AP 47/57/67/77/97Series7000-Rev.2,3,5Series 1000 - Rev. 1, 5
991523
AL, ALE, A2L, AR, AP2, AT2, AP3, AT3 35/45/55/65/75/95Series 9000 - Rev. 4, 6 991524
AL, ALE, A2L, AR, AP2, AT2, AP3, AT3 35/45/55/65/75/95Series 9000 - Rev. 1, 2, 5 991523
AUV, ATUV 991524
Service kitAN, AE, AS, AL, ALE, AUV, A2L, AR, AP, AT, ATUV - Low cover 991533
AN, AE, AS, AL, ALE, A2L, AR, AP, AT - High cover 991510
8
54
Description Pump type Reference
Solenoid tube (7)
AS, AP2, AP3ATUV (SV2)* 991430
AL rev. 2, 4, 5, 6
991502
AR, A2L
ALE, AUVATUV (SV1)* 991600
*Refer to page 618
55
Description Pump type Reference
Solenoid tube (7)
AP 991430
AT2, AT3rev. 2, 4, 6 991503
8
56
Description Pump type Reference
Solenoid valve (8)
AS, ATUV (SV2)*220-240V;50/60Hz 991435
AS, ATUV (SV2)*110-120V;50/60Hz 991431
AS, ATUV (SV2)*24V;50/60Hz 991432
AL, A2L, AR220-240V;50/60Hz 3713871SAV+991502
AL, A2L, AR110-120V;50/60Hz 3713824+991502
AL, A2L, AR24V;50/60Hz 3713823+991502
*Refer to page 618
57
Description Pump type Reference
Solenoid valve (8)
ALE, AUV, ATUV (SV1)*220-240V;50/60Hz 3713871SAV+991600
ALE, AUV, ATUV (SV1)*110-120V;50/60Hz 3713824+991600
ALE, AUV, ATUV (SV1)*24V;50/60Hz 3713823+991600
AP220-240V;50/60Hz 991455
*Refer to page 61
8
58
Description Pump type Reference
Solenoid valve (8)
AP2, AP3220-240V;50/60Hz 991488
AT2, AT3220-240V;50/60Hz 3713871SAV+991503
8
59
9. Connections
AN/AE AS/AL/ALE
AN/AE/AS/AL/ALE pumps
Figures are for "C" shaft rotation and nozzle outlet.
Figures are for "C" shaft rotation and nozzle outlet.
S: SuctionG1/8orG1/4N : Nozzle outlet G 1/8R : Return G 1/8 or G 1/4V : Vacuum gauge port G 1/8P : Pressure gauge port G 1/8A : Pressure adjustmentr: Rotationdirectionbp: By-passplugfor2-pipeoperation
V V
A A
P PP P
P P
N N
S Sr rR + bp R + bp
9
60
AUV 47 L 9877 6P 0700 AUV 47 R 9876 6P 0700
S: SuctionG1/4R : Return G 1/4N1 : Nozzle outlet G 1/8N2 : OptionalnozzleoutletG1/8V : Vacuum gauge port G 1/8P : Pressure gauge port G 1/8A : Pressure adjustmentr : Rotationdirectionbp: By-passplugfor2-pipeoperation
V V
N2 N1
A A
P P
N1 N2
S Sr rR + bp R + bp
AUV one-stage service pump
Combined with a nozzle incorporating a cut-off function, these models allow to take advantage of the additional nozzle line pressure relief solenoid valve feature.
9
61
ATUV 45 L 9860 6P 0700 ATUV 45 R 9861 6P 0700
S: SuctionG1/4R : Return G 1/4N1 : Nozzle outlet G 1/8N2 : OptionalnozzleoutletG1/8SV1:Blockingsolenoidvalve(NC)SV2 : Switching low/high modes (1/2)V : Vacuum gauge port G 1/8P : Pressure gauge port G 1/8A1 : Low pressure adjustmentA2 : High pressure adjustmentr : Rotationdirection
V
N2
SV2 SV2
A2
P P
N1
SV1 SV1
RrS
ATUV two-stage service pump
A1
V
N2
A2
N1
RrSA1
Combined with a nozzle incorporating a cut-off function, these models allow to take advantage of the additional nozzle line pressure relief solenoid valve feature.
9
62
10. One-pipe ↔ two-pipe configuration
Most SUNTECpumps aredeliveredprepared for two-pipe installations. They canbe converted, exceptATUVmodels,toone-pipeoperationbyremovingtheinternalby-passplugandfittingaplugandawashertothereturnportthuscreatinganinternalrecirculationcircuit.
1-pipe(Removeby-passplug)
2-pipe(By-passpluginsertedinreturn)
10
63
11. Pipe Dimensions
Ratedspeed:2850rpm-Viscosity:5mm²/s(cSt)-Pressure:9barsTheannexedchartsgivethemaximumlength(inmeters)ofsuctionlineasafunctionof3variables:liftbetweenfuelunitandtank(H),nozzlecapacityorpumptype,pipediameter(d),foranaltitudeof200mabovesealeveland0,45barsvacuum.Thelengthindicated(intersectionofhorizontallinesandcolumns)assumesthefittingof4rightanglebends,1stopvalve,1nonreturnvalve;ifadditionalrestrictionsexist(particularlythefilterofthesuctionline),thelengthmustbereducedaccordingly.Onlymentioneddiameterscanbeused,biggerpipesarenotsuitable.Altitude correction:ifXisthealtitude(differentfrom200m), - Lift system:addthevalue(X-200)/1000totherealliftheight"H",toobtaintheequivalentlift, thendeterminethemaximumlengthwiththeannexedcharts. - Siphon feed system:reducetherealheadheight"H"by(X-200)/1000.E.g.:AS47pumpintwo-pipeliftsystem,withliftheight=1,5m,altitude=700m,pipediameter=8mm.Equivalentliftheight:1,5+(700-200)/1000=2m,maximumpipelength=26m.Pressure correction: only for one-pipe system.IfPisthepressure(differentfrom9bars),usethetheoreticalequivalentnozzlecapacity=(√P/3)xrealnozzle capacity.E.g.:one-pipeliftsystem,withnozzle=0,60GPH,pressure=22bars,pipediameter=4mm,suctionheight=3m.Equivalentnozzlecapacity=(√22/3)x0,60=0,94GPH.Themaximumpipelengthiscomprisedbetween17m(correspondingto0,80GPH)and14m(correspondingto1,00GPH),thatmeansaround15m.
11
64
One-pipe siphon feed system
One-pipeliftsystemNozzle
Nozzle
11
65
Two-pipe siphon feed system
Two-pipeliftsystem
*Q = pump capacity @ 0 bar
Pump
Pump 35/45/47
35/45/47
55/57
55/57
65/67
65/67
75/77
75/77
95/97
95/97
11
66
12. FAQs
12.1 Pump is not running
Check if… Probable explanation Solution
…the motor is turning.
YES Motor coupling is defectiveor hascame loose
Check coupling and repair or replace as appropriate.
NO
Pump has seized
Remove pump cover and check pump. If rust and / or an abnormal amountof dirt are found, check tank for water andcheckconditionoffilters.Replacepump.
Motor does not workTestmotorandconnectionsandrepairor replace if necessary, having firstexaminedthepump.
12
67
Check if… Probable explanation Solution
…oil flows out of the high-pressure port when it is loosened.
YES
Nozzle or in-line solenoid valve is blocked
Inspect nozzle and valve for blockage(dirt, grit, fuel,...)
Solenoid valve or pressure regulator isdefective
Switchonthecoilandcheckformagneticpull. If there is no pull, check the current. If the current is OK, change the coil.
When the coil is in order, check the pressure regulating valve or replace thepump.
12.2 Pump is running but does not deliver oil
12
68
Check if… Probable explanation Solution
…no oil flows from the high-pressure port when it is loosened.
NO
Oil level in tank is low Checktankandrefill.
Inlet pipe valve is closed Open the valve.
On a new installation, the checkvalve is the wrong way round
Check that all valves are facing the right way.
…and vacuum gauge shows a high vacuum.
YESBlockageup-stream Checkin-linefilterandnon-returnvalve.
Pipe is undersized Check pipe dimensions.
12
69
Check if… Probable explanation Solution
…no oil flows from the high-pressure port when it is loosened.
…and vacuum gauge shows a low vacuum.
YES
Pumpfilterisplugged Remove pump cover and check filtercondition.
Air leakCheckthetightnessofpumpcover(especiallyif the filter has recently been changed/cleaned) and check the cover gasket.
Pipe is oversized Very important for one-pipe systems. Check pipe diameter.
Pump rotates in a wrong way
Iftheinstallationisnew,besurethatmotorand pump rotation are the same. A pumpturning inthewrongdirectioncannotdrawoil.
By-passplugismissingintwo-pipeinstallation Checkiftheby-passplugisinstalled.
12
70
Check if… Probable explanation Solution
…no oil flows from the high-pressure port when it is loosened.
…and vacuum gauge shows a low vacuum.
YES
Suction and return lines havebeenswapped Checktheyhavebeencorrectlyfitted.
Pump is worn out Checkthisbycarryingoutapressuretest.
12
71
Check if… Probable explanation Solution
…the pressure can be adjusted.
…and pressure gauge shows a low pressure.
YES
Pump is not properly sized for the nozzle performance (rememberingfuel viscosity) or any hydraulic attachmentsi.e.hydraulicallyopenedairflap
Change pump or nozzle as appropriate.
Pump is worn out Checkthisbycarryingoutapressuretest.Replace pump.
…and pressure gauge shows a high pressure.
YES Dirtinregulatingvalve Dismantle pressure regulator or replace pump.
12.3 Nozzle pressure is too high / too low
12
72
Check if… Probable explanation Solution
…the pressure can be adjusted.
…and the pump pressure oscillates.
YES
Air in the oil Checkvacuumdoesnotexceed0,45bars.Checksuctionlineforleaks.
Pressure regulating valve isdefectiveorclogged
Dismantle pressure regulator or replace pump.
Motor coupling is slipping Check coupling and check for speed variations.
…the pressure can not be adjusted.
…and the pressure is constantly too high or too low.
YES Pressure regulating valve isdefectiveorclogged
Dismantle pressure regulator or replace pump.
NO Pressure gauge is defective orincorrectly installed Checkpressuregauge.Bleedwhenfitting.
12
73
Check if… Probable explanation Solution
…an increasingly loud whine is coming from the pump.
YES Vacuum is too high (check with a vacuum gauge)
Check for closed valves, blocked filters,check valves that are stuck.
…the pump generates a cracking noise and the pressure gauge oscillates.
YES Airbubblesinthesuctionline Checksuctionlineforleaks.Bleedpumpifinstallationisone-pipe.
12.4 The oil pump makes noise
12
74
Check if… Probable explanation Solution
…a small nozzle flow is used with a one-pipe installation.
YESHeat build-up from recirculationin pump plus heat radiated from motor etc.
Converttotwo-pipeorfitfilterupstreamfrom pump with return from pump to filter. This circulation outside of theburnerwillhelptocoolthesystem.
12.5 Excessive pump temperature
12
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
77Allrightsreserved–Informationanddataaresubjecttochangewithoutpriornotice.Edition2018
www.suntec.fr
Top Related