138
Our SCALA laboratory furniture system provides you the greatest possible selection of storage variations for quick access and safe storage.
All storage cabinets are variably equipable and allow for the optimal use of space in all sorts of laboratories.
Designed with a sophisticated appearance – manufac-tured with Wadner‘s high quality.
The laboratory cabinets can be extended, upgraded and are, of course, compatible – for problem-free adapta-tion to new requirements.
We place special value on durability. Even after thou-sands of load changes, hinges, pull-out rails and surfaces must not give in. First-class materials, carefully processed, guarantee long durability – with certainty.
Along with laboratory cabinets, suspended cabinets, top-mounted cabinets, underbench cabinets and pull-out cabinets, we have exhaust cabinets for the safe storage of typical laboratory items such as solvents, acids, bases and gas cylinders as well as for the disposal of chemicals.
4 Storagecabinets
139
Sto
rag
e ca
bin
ets
34
Underbench units 142Underbenchonplinth 142Underbenchunitoncasters 144Suspendedunderbenchunit 146Self-supportingunderbenchunitforfumehoods 148Pushed-inunderbenchunitforfumehoods 151Underbenchunitforsinks 152
Suspended cabinets 155
Laboratory cabinets 157Laboratorycabinet 157Emergencycabinet 161
Top-mounted cabinets 162
Pull-out cabinets 163
Exhaust cabinets 165Laboratorycabinetforstorageofacidsandbases 165Underbenchunitforfumehoods,forthestorageofacidsandbases 167FWF90underbenchunitforfumehoods,forthestorageofflammableliquids 169FWF90laboratorycabinetforthestorageofflammableliquids 171G90cabinetforgascylinders 173
140
GreatnumberofoptionsFor the highest flexibility in the laboratory we provide
our cabinets and underbench units in the widest variety of designs. Pushed-in underbench units in plinth and movable designs are in best position under C-frames, H-frames, cantilever frames or under fume hoods with individual support structures.
Suspended underbench units are attached directly under the worktop, or as a sliding variant in cantilver sup-port frames.
DesignandfunctiongohandinhandThe jointless handles made from die-cast aluminum
are chemical resistant and can be cleaned easily. Special emphasis can be placed in the laboratory design through the use of walnut decor set into the fronting. The attach-ment of our suspended cabinets on the service spines or on the wall can be effected without an observable gap.
MoremobilityinthelaboratoryWith four smooth-running casters, two of them
lockable, our movable underbench units can be posi-tioned simply in the frame on add-on tables or laboratory benches. The caster height is also harmonized and flush with the plinth height of our fixed cabinets.
MoresafetydetailsOur movable underbench units are made tilt-resistant
through self-locking protection and the pull-out catch of the drawer compartment. Our tall cabinets have an inte-grated rail on the inside for safely suspending a ladder.
Storagecabinets3 Storagecabinets4
141
Sto
rag
eca
bin
ets
34
MoreuseablestoragespaceWith an underbench depth of 21.65 in (550 mm) and
the drawer compartment depth of 19.69 in (500 mm) we provide the best usable storage space on the market. Even in corner cabinets, we have expanded the usable storage space by means of new service outlets.
SurfacesandedgesareoptimallyprotectedThe melamine resin coated faces are easy to clean
and robust against the effects in the laboratory. The front edges on the carcass and on the shelves are equipped with impact resistant 0.08 in (2 mm) polypropylene edg-es. In addition, the foil-coated plinths of our furnishings are manufactured out of waterproof bonded plywood.
OptimalpositioningDue to four height-adjustable feet, our laboratory
cabinets and underbench units can be set up straight and absolutely stable with plinths.
Fullyextendabledrawercompartmentswithcon-cealedrollerrails
The double-wall steel frame with concealed roller rails is more stable, protected against soiling and thus operates more easily than single wall frames with open roller rails. Our standard full extension creates a complete overview. With soft close upon request.
SafetyforproblematicsubstancesOur security cabinets for gasses, acids and bases as
well as flammable liquids meet the highest requirements on material properties and function. Naturally, in accor-dance with current standards.
142
Sto
rag
eca
bin
ets
UnderbenchunitsUnderbenchunitonplinth
4Use�� For storage of instruments and chemicals, according to DIN EN 14727�� For working heights of 29.53 in (750 mm) and 35.43 in (900 mm)
�� Not to be used for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Variants
Underbenchunitonplinth
143
Sto
rag
eca
bin
ets
UnderbenchunitsUnderbenchunitonplinth
4TechnicalData
Dimensions
Width [in] (mm) 17.72 (450) 23.62 (600) 35.43 (900) 47.24 (1200)
Depth [in] (mm) 21.65 (550)
Total height [in] (mm) 28.35 (720)34.25 (870)
Height, drawer compartments [in] (mm) 5.91 (150)7.87 (200)
15.75 (400)For possible combinations, see variants
Height, plinth [in] (mm) 4.33 (110)
Loadbearingcapacity
Each shelf/drawer compartment [lb] (kg) 66.14 (30)
Relevantfeatures
Design For working heights of 29.53 (750) and 35.43 in (900 mm)Hinged door with 270° hingesFully extendable drawer compartmentsOpen top, detachable rear wallShelf, height-adjustableWithout doors as a rack4 height-adjustable feet
Possible combinations See variants
Handle Handle bar SCALAU handle stainless steel
Drawer compartments with change pull-out catch
Optional
Full-height drawers Optional
Move-in damper for drawer compartments Optional
Extract air spigot Optional
Locking device Optional
144
Sto
rag
eca
bin
ets
UnderbenchunitsUnderbenchunitoncasters
4Use�� For flexible storage of instruments and chemicals, according to DIN EN 14727�� For working heights of 29.53 in (750 mm) and 35.43 in (900 mm)
�� Not to be used for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Variants
Underbenchunitoncasters
145
Sto
rag
eca
bin
ets
UnderbenchunitsUnderbenchunitoncasters
4TechnicalData
Dimensions
Width [in] (mm) 17.72 (450) 21.46 (545) 23.62 (600) 33.27 (845) 35.43 (900) 45.08 (1145) 47.24 (1200)
Depth [in] (mm) 21.65 (550)
Total height [in] (mm) 25.2 (640)31.1 (790)
Height, drawer compartments [in] (mm) 5.91 (150)7.87 (200)
13.78 (350)For possible combinations, see variants
Height, casters [in] (mm) 4.33 (110)
Loadbearingcapacity
Each shelf/drawer compartment [lb] (kg) 66.14 (30)
Each caster [lb] (kg) 154.32 (70)
Relevantfeatures
Design For working heights of 29.53 (750) and 35.43 in (900 mm)Hinged door with 270° hingesFully extendable drawer compartments and change-pull-out catchesShelf, height-adjustableWithout doors as a rackTop covered, rear wall firmly connected with carcass4 swivelling casters, front casters lockable
Possible combinations See variants
Handle Handle bar SCALAU handle stainless steel
Move-in damper for drawer compartments Optional
Locking device Optional
146
Sto
rag
eca
bin
ets
UnderbenchunitsSuspendedunderbenchunit
4Use�� For flexible storage of instruments and chemicals, according to DIN EN 14727�� For working heights of 29.53 in (750 mm) and 35.43 in (900 mm)
�� Not to be used for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Variants
Suspendedunderbenchunit
147
Sto
rag
eca
bin
ets
UnderbenchunitsSuspendedunderbenchunit
4TechnicalData
Dimensions
Width [in] (mm) 17.72 (450) 21.46 (545) 23.62 (600) 33.27 (845) 35.43 (900) 45.08 (1145) 47.24 (1200)
Depth [in] (mm) 19.69 (500) (depth of frame, 22.52 (572))21.62 (550) (depth of frame, 26.46 (672))
Height [in] (mm) 14.96 (380)20.87 (530)
Height, drawer compartments [in] (mm) 5.91 (150)7.87 (200)
13.78 (350)For possible combinations, see variants
Loadbearingcapacity
Each shelf/drawer compartment [lb] (kg) 66.14 (30)
Relevantfeatures
Design For working heights of 29.53 (750) and 35.43 in (900 mm)2 service outlets for replacements in the profile rail of the bench frameHinged door with 270° hingesFully extendable drawer compartmentsTop covered, rear wall firmly connected with carcassShelf, height-adjustableWith C frame/cantilever frame, laterally movable over the table gridHinged door(s) with 1 shelf, height 20.87 in (530 mm)Height of 20.87 in (530 mm) without doors, with 1 shelf
Possible combinations See variants
Handle Handle bar SCALAU handle stainless steel
Drawer compartments with change pull-out catch
Optional
Move-in damper for drawer compartments Optional
Locking device Optional
148
Sto
rag
eca
bin
ets
UnderbenchunitsSelf-supportingunderbenchunitforfumehoods
4Use�� For storage of instruments and chemicals, according to DIN EN 14727�� For fume hoods with services on baffle and side walls
�� Not to be used for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Forfumehoodswithservicesonbaffle
Forfumehoodswithservicesonsidewalls
Self-supportingunderbenchunitforfumehoods
149
Sto
rag
eca
bin
ets
UnderbenchunitsSelf-supportingunderbenchunitforfumehoods
4Variants
Forfumehoodswithservicesonbaffle
Forfumehoodswithservicesonsidewalls
150
Sto
rag
eca
bin
ets
UnderbenchunitsSelf-supportingunderbenchunitforfumehoods
4TechnicalData
Dimensions
Width [in] (mm) 23.62 (600) 35.43 (900) 47.24 (1200)
Depth [in] (mm) 21.65 (550)
Total height [in] (mm) 27.95 (710)32.28 (820)
Height, plinth [in] (mm) 4.33 (110)
Loadbearingcapacity
Each shelf [lb] (kg) 66.14 (30)
Relevantfeatures
Design Hinged door with 270° hingesService panel on top of the storage cabinet for fume hoods with services on baffleCovered top, detachable rear wallShelf, height-adjustable4 height-adjustable feet
Possible combinations See variants
Full-height drawers Optional
Extract air duct Optional
Underbench exhaust Optional
Acids-bases-equipment Optional
Locking device Optional
Handle Handle bar SCALAU handle stainless steel
151
Sto
rag
eca
bin
ets
UnderbenchunitsPushed-inunderbenchunitforfumehoods
4Use�� For storage of instruments and chemicals, according to DIN EN 14727�� For fume hoods with services on baffle and side walls, on steel support frame
�� Not approved for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not approved for storage of acids and bases
Design
Variants
TechnicalData
Dimensions
Width [in] (mm) 21.46 (545) 23.62 (600) 33.27 (845) 35.43 (900) 45.08(1145) 47.24 (1200)
Depth [in] (mm) 21.65 (550)
Total height [in] (mm) pushed-in underbench unit for bench-mounted fume hood, with services on baffle
25.2 (640)
Total height [in] (mm) pushed-in underbench unit for bench-mounted fume hood, with services on side walls
28.19 (716)
Height, plinth [in] (mm) 4.33 (110)
Loadbearingcapacity
Each shelf [lb] (kg) 66.14 (30)
Relevantfeatures
Design Hinged door with 270° hingesOpen top, detachable rear wallShelf, height-adjustable4 height-adjustable feet
Possible combinations See variants
Handle Handle bar SCALAU handle stainless steel
Full-height drawers Optional
Extract air duct Optional
Underbench exhaust Optional
Locking device Optional
Pushed-inunderbenchunitforfumehoods
152
Sto
rag
eca
bin
ets
UnderbenchunitsUnderbenchunitforsinks
4Use�� As underbench unit for sinks, for storage of instruments and chemicals, according to DIN EN 14727
�� Not to be used for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Sinkwithunderbenchunitforservicespinesoronthewall
Frontendsinkforislandbenches
Underbenchunitforsinks
153
Sto
rag
eca
bin
ets
UnderbenchunitsUnderbenchunitforsinks
4Variants
Sinkwithunderbenchunitforservicespinesoronthewall
Frontendsinkforislandbenches
154
Sto
rag
eca
bin
ets
UnderbenchunitsUnderbenchunitforsinks
4TechnicalData
Dimensions
Width [in] (mm) 23.62 (600)1) 35.43 (9001)) 47.24 (12001)) 55.91 (14202)) 67.72 (17202))
Depth [in] (mm) 21.65 (550) 21.65 (550) 21.65 (550) 27.56 (700) 27.56 (700)
Total height [in] (mm) 34.25 (870) 34.25 (870) 34.25 (870) 34.25 (870) 34.25 (870)
Height, plinth [in] (mm) 4.33 (110) 4.33 (110) 4.33 (110) 4.33 (110) 4.33 (110)
1) For sinks on service spines or on the wall2) For front end sinks
Loadbearingcapacity
Each shelf/drawer compartment [lb] (kg) 66.14 (30)
Relevantfeatures
Design Hinged door with 270° hinges 4 height-adjustable feet Inclined swivel door with waste bin 7.93 gal (30 l) Waste bin 2 x 3.96 gal (15 l) with full-height drawer Waste bin 2 x 9.24 gal (35 l) with full-height drawer Hinged door(s), full-height drawer Combination possibilities see variants
Handle Handle bar SCALAU handle stainless steel
Locking device Optional
155
Sto
rag
eca
bin
ets
SuspendedcabinetsSuspendedcabinet
4Use�� For storage of instruments and chemicals, according to DIN EN 14727
�� Not approved for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not approved for storage of acids and bases
Design
Variants
Suspendedcabinet
156
Sto
rag
eca
bin
ets
SuspendedcabinetsSuspendedcabinet
4
TechnicalData
Dimensions
Width [in] (mm) 17.72 (450) 23.62 (600) 35.43 (900) 47.24 (1200)
Depth [in] (mm) 13.78 (350)
Height [in] (mm) 18.11 (460)29.92 (760)
Loadbearingcapacity
Each shelf [lb] (kg) 66.14 (30)
Total load bearing capacity [lb] (kg) 132.28 (60)
Relevantfeatures
Design Automatic level fitting for fastening to wall/service spineWidth of 47.24 in (1200 mm) with central panelShelf, height-adjustable
Possible combinations See variants
Handle U handle SCALAU handle stainless steelPlastic handle affixed to glass sliding door
Shelf with inclined side walls Optional
Locking device Optional
157
Sto
rag
eca
bin
ets
LaboratorycabinetsLaboratorycabinet
4Use�� For storage of instruments and chemicals, according to DIN EN 14727
�� Not approved for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not approved for storage of acids and bases
Design
Laboratorycabinet
160
Sto
rag
eca
bin
ets
LaboratorycabinetsLaboratorycabinet
4TechnicalData
Dimensions
Width [in] (mm) 17.72 (450) 23.62 (600) 35.43 (900) 47.24 (1200)
Depth [in] (mm) 13.78 (350)21.65 (550)
Total height [in] (mm) 82.28 (2090)
Height, plinth [in] (mm) 4.33 (110)
Loadbearingcapacity
Each shelf/drawer compartment [lb] (kg) 66.14 (30)
Relevantfeatures
Design Hinged door with 270° hingesShelves, height-adjustableFully extendable drawer compartments4 height-adjustable feet
Possible combinations See variants, drawers only with depth 21.65 in (550 mm)
Handle U handle SCALAU handle stainless steel
Shelves, extendable Optional (with cabinet depth of 21.65 in (550 mm))
Drawer compartments with change pull-out catch
Optional (with cabinet depth of 21.65 in (550 mm))
Move-in damper for drawer compartments Optional
Extract air duct Optional
Locking device Optional
161
Sto
rag
eca
bin
ets
LaboratorycabinetsEmergencycabinet
4Use�� For storage of protective equipment and rescue equipment (fire extinguisher, first aid kit etc.)
�� Not approved for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not approved for storage of acids and bases
Design
TechnicalData
Dimensions
Width [in] (mm) 23.62 (600)
Depth [in] (mm) 13.78 (350)21.65 (550)
Total height [in] (mm) 82.28 (2090)
Height, plinth [in] (mm) 4.33 (110)
Relevantfeatures
Design Hinged door with 270° hinges2 shelves, height-adjustable4 height-adjustable feet
Optional equipment 1 first aid kit1 CO2 fire extinguisher, 11.02 lb (5 kg)2 fiber glass fire blankets2 sand boxes1 sand shovel1 instruction label with first aid instructions
Emergencycabinet
162
Sto
rag
eca
bin
ets
Top-mountedcabinetsTop-mountedcabinet
4Use�� For storage of instruments and chemicals, according to DIN EN 14727�� Only suitable as permanently installed top part for the following Waldner cabinets: Laboratory cabinet, pull-out cabinet, emergency cabinet as well as acid and base cabinet
�� Not approved for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not approved for storage of acids and bases
Design
TechnicalData
Dimensions
Width [in] (mm) 17.72 (450) 23.62 (600) 35.43 (900) 47.24 (1200)
Depth [in] (mm) 13.785 (350)21.65 (550)
Height [in] (mm) 24.02 (610)29.92s (760)
Loadbearingcapacity
Each shelf [lb] (kg) 66.14 (30)
Relevantfeatures
Design With integrated rail for suspending a ladderFor laboratory cabinets with or without extract air spigot1 shelf, height-adjustable
Door Hinged door(s)
Handle U handle SCALAU handle stainless steel
Connecting ladder Optional
Locking device Optional
Top-mountedcabinet
163
Sto
rag
eca
bin
ets
Pull-outcabinetsPull-outcabinet
4Use�� For storage of liquid or solid substances in suitable containers containers, according to DIN EN 14727
�� Not approved for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances�� Not approved for storage of acids and bases
Design
2
1
1 Wire basket with tray 2 Pull-out
Pull-outcabinet
164
Sto
rag
eca
bin
ets
Pull-outcabinetsPull-outcabinet
4TechnicalData
Dimensions
Width [in] (mm) 23.62 (600) 35.43 (900)
Depth [in] (mm) 21.65 (550)
Total height [in] (mm) 82.28 (2090)
Height, plinth [in] (mm) 4.33 (110)
Full-height drawer, width x depth [in] (mm) 11.81 (300) x 19.69 (500)
Tray, width x depth x height [in] (mm) 9.45 (240) x 16.73 (425) x 1.57 (40)
Loadbearingcapacity
Each pull-out [lb] (kg) 220.46 (100)
Each tray [lb] (kg) 22.05 (10)
Relevantfeatures
Design 5 wire baskets with trays for each drawer, height-adjustable Wall fastening4 height-adjustable feet
Door Pull-out doors with pull-outs accessible from both sides
Handle U handle SCALAU handle stainless steel
Move-in damper Optional
Compartment partitioning Optional
Extract air spigot Optional
Locking device Optional
Material
Trays Polyethylene
165
Sto
rag
eca
bin
ets
ExhaustcabinetsLaboratorycabinetforstorageofacidsandbases
4Use�� For storage of limited quantites of acids and bases�� Not to be used for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances
Design
Laboratorycabinetforstorageofacidsandbases
166
Sto
rag
eca
bin
ets
ExhaustcabinetsLaboratorycabinetforstorageofacidsandbases
4TechnicalData
Dimensions
Width [in] (mm) 23.62 (600)
Depth [in] (mm) 21.65 (550)
Total height [in] (mm) 82.28 (2090)
Height, plinth [in] (mm) 4.33 (110)
Loadbearingcapacity
Fixed shelf [lb] (kg) 66.14 (30)
Extendable shelves [lb] (kg) 44.09 (20)
Relevantfeatures
Design Connection to permanently working ventilation system4 shelves, fixed or extendableSeparate compartments for acids and basesPolypropylene collecting trayCoated fittings4 height-adjustable feet
Door Hinged doors
Handle U handle SCALAU handle stainless steel
Ventilationdata
Volume flow [cfm] (m³/h) 58.9 (100)
Ventilation connection Ø [in] (mm) 3.54/4.33 (90/110)
Connection height extract air spigot [in] (mm) 85.67 (2176)
167
Sto
rag
eca
bin
ets
4Exhaustcabinets
Use�� Pushed-in or self-supporting underbench unit for bench-mounted fume hoods, for storage of limited quantities of acids and bases
�� Not to be used for storage of flammable liquids, gas cylinders, and spontaneously flammable or decomposing substances
Design
Variants
Pushed-inunderbenchunits
Self-supportingunderbenchunitsforfumehoodswithservicesonbaffle
Self-supportingunderbenchunitsforfumehoodswithservicesonsidewalls
Underbenchunitforfumehoodsforthestorageofacidsandbases
168
Sto
rag
eca
bin
ets
4 ExhaustcabinetsUnderbenchunitforfumehoodsforthestorageofacidsandbases
TechnicalData
Dimensions
Width [in] (mm) 23.62 (600) 35.43 (900)
Depth [in] (mm) 21.65 (550)
Total height [in] (mm) for pushed-in underbench units for bench-mounted fume hood, with services on baffle
25.2 (640)
Total height [in] (mm) for pushed-in underbench units for bench-mounted fume hood, with services on side walls
28.19 (716)
Total height [in] (mm) for self-supporting underbench units for bench-mounted fume hood, with services on baffle/side walls
27.95 (710)
Height for plinth [in] (mm) 4.33 (110)
Loadbearingcapacity
Extendable shelves [lb] (kg) 44.09 (20)
Relevantfeatures
Design Connection to permanently working ventilation systemCoated fittings2 extendable shelves, with collecting trays 4 height-adjustable feet
Door Hinged doorFor possible combinations, see variants
Handle Handle bar SCALAU handle stainless steel
Ventilationdata
Volume flow [cfm] (m³/h) 17.7 (30)
Ventilation connection to the ascending duct Ø [in] (mm)
3.54 (90)
169
Sto
rag
eca
bin
ets
4Exhaustcabinets
Use�� Pushed-in underbench unit for bench-mounted fume hoods for storage of limited quantities of flammable liquids�� Not to be used for gas cylinders and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Variants
FWF90underbenchunitforfumehoodsforthestorageofflammableliquids
170
Sto
rag
eca
bin
ets
4 ExhaustcabinetsFWF90underbenchunitforfumehoodsforthestorageofflammableliquids
TechnicalData
Dimensions
Width [in] (mm) 23.62 (600) 35.43 (900) 43.31 (1100) 55.12 (1400)
Depth [in] (mm) 23.62 (600)
Total height [in] (mm) 25.0 (635)
Height, plinth [in] (mm) 1.38 (35)
Weight, max. [lb] (kg) 286.6 (130) 374.78 (170) 485.01 (220) 639.33 (290)
Loadbearingcapacity
Fixed shelf [lb] (kg) 66.14 (30)
Drawer [lb] (kg) 55.12 (25)
Relevantfeatures
Design Connection to permanently working ventilation systemConnection to grounding line with potential equalizationWith locking deviceBasin bed with perforated sheet metal elementAutomatic locking through current-independent thermal activation, in case of fireHinged doorDrawer
Possible combinations See variants
Handle Stainless steel U handle
Additional tray extension Optional for drawers
Ventilationdata
Volume flow [cfm] (m³/h) 17.7 (30)
Ventilation connection to the ascending duct Ø [in] (mm)
3.54 (90)
Material
Underbench unit Powder-coated steel exterior, color: Light gray RAL 7035
Ventilation connection PPS
171
Sto
rag
eca
bin
ets
4Exhaustcabinets
Use�� For storage of limited quantities of flammable liquids�� Not to be used for gas cylinders and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Variants
FWF90laboratorycabinetforthestorageofflammableliquids
172
Sto
rag
eca
bin
ets
4 ExhaustcabinetsFWF90laboratorycabinetforthestorageofflammableliquids
TechnicalData
Dimensions
Width [in] (mm) 23.62 (600) 35.43 (900) 47.24 (1200)
Depth [in] (mm) approx. 23.62 (600)
Total height [in] (mm) approx. 78.74 (2000)
Height, plinth [in] (mm) approx. 3.15 (80)
Weight, max. [lb] (kg) 639.33 (290) 793.66 (360) 1036.16 (470)
Loadbearingcapacity
Basin bed [lb] (kg) Dependent on design
Relevantfeatures
Design Connection to permanently working ventilation systemConnection to grounding line with potential equalizationIn case of fire, automatic locking through current-independent thermal activation3 basin beds, height-adjustableBasin bed with perforated sheet metal elementWith locking device4 height-adjustable feetHinged door
Possible combinations See variants
Additional designs and equipment Available on request
Regulations and standards DIN EN 14470-1TRbF 20 (German ordinance on flammable liquids)
Ventilationdata
Volume flow [cfm] (m³/h) 17.7 (30)
Ventilation connection Ø [in] (mm) 2.95 (75)
Material
Laboratory cabinet Powder-coated steel exterior, color: Light gray RAL 7035
Ventilation connection Galvanized steel
173
Sto
rag
eca
bin
ets
4Exhaustcabinets
Use�� For storage of gas cylinders in buildings�� Not to be used for storage of flammable liquids and spontaneously flammable or decomposing substances�� Not to be used for storage of acids and bases
Design
Variants
G90cabinetforgascylinders
174
Sto
rag
eca
bin
ets
4 ExhaustcabinetsG90cabinetforgascylinders
TechnicalData
Dimensions 23.62(600) 35.43(900) 47.24(1200) 55.12(1400)
Width [in] (mm) 23.2 (600) 35.43 (900) 47.24 (1200) 55.12 (1400)
Depth [in] (mm) approx. 23.62 (600)
Total height [in] (mm) approx. 78.74 (2000)
Empty weight max. [lb] (kg) 859.79 (390) 1168.44 (530) 1455.04 (660) 1631.4 (740)
Relevantfeatures 23.62(600) 35.43(900) 47.24(1200) 55.12(1400)
Design Connection to permanently working ventilation systemMounting rails for incorporation of compressed gas reduction unitsRamp for rolling in gas cylindersWith locking device4 height-adjustable feetDucts for piping and cables in cabinet cover
Door Hinged door(s)
Max. number of 13.2 gal (50 l) by cabinet width
1 3 4 5
Additional designs and equipment Available on request
Ventilationdata 23.62(600) 35.43(900) 47.24(1200) 55.12(1400)
Volume flow [cfm] (m³/h) by cabinet width 35.3 (60) 53 (90) 70.6 (120) 82.4 (140)
Ventilation connection Ø [in] (mm) 2.95 (75)
Material
Laboratory cabinet Powder-coated steel exterior, color: Light gray RAL 7035
Ventilation connection Galvanized steel
Top Related