STEAM SEPARATORS
Size Range: 1,000 lbs/hr to 50,000lbs/hr nominal steam rate
These horizontal steam separators were designed specifically for use with Maxim heat recovery equipment and usage on reciprocating engines and gas turbines.
Functions
• Separates liquid and vapor entering the HSS• Serves as a liquid reservoir and liquid level control point for the system• Serves as a trap and blow down point for sludge and other contaminants circulated in the system• Mounts safety valves, level alarm switches, pressure gauges and other devices for protection of the system
First stage separation is accomplished by an impact plate which provides constant steam quality regardless of water velocity and allows major nozzles to be located on the centerline of the vessel. Additional baffling and surface control plates minimize frothing and liquid carryover. Standard configurations give a minimum steam quality of 98%. With optional mesh type mist eliminators, solids carry over is limited to 1 part per million from liquid concentrations as high as 2,000 parts per million.
Standard Trim Components
• Liquid level controller• Safety valve• Visual liquid level gauge• Surface blow-off valve• Automatic air venting• Liquid drain valve• Pressure indicator• High liquid level indicator• Low liquid level indicator
MAXIM SILENCERS, INC. Rev. 12.01.08
HSS
Liquid-Vapor Separation in Steam Generating Systems
AP
PLI
CA
TIO
NS:
CO
DE
CO
MP
LIA
NC
E The Maxim HSS heat recovery unit is designed and fabricated in compliance with Section VIII or Section I, Division I, ASME Code.
• Hospitals• Schools• Office buildings• Shopping centers• Offshore platforms• Oil & Gas production facilities• Industrial plants• Marine
DRAWINGS
MAXIM SILENCERS, INC. Rev. 12.01.08
HSS
HSS
10
20
56 5 ⁄8
29
5 ⁄16
22 5 ⁄1
6 44
5 ⁄8
11
8 5
5 7 ⁄8
11
39
3 ⁄8
29 3 ⁄8
15
18
16
1 ⁄8
6 1 ⁄8
4
3 3
1 67
0 89
0 11
10H
SS 2
0 24
64
5 ⁄8
33 5 ⁄1
6 26
5 ⁄16
52 5 ⁄8
13
11
6
7 3 ⁄4
14
43
3 ⁄8
31 3 ⁄8
17
20
16
1 ⁄8
7 7 ⁄8
6
4 4
1 84
0 12
09
1578
HSS
40
30
73 5 ⁄8
37
13⁄16
30
13⁄16
61
5 ⁄8
16
13
7 1 ⁄2
9
3 ⁄4
17
49 3 ⁄8
34
3 ⁄8
20
23
16 1 ⁄8
10
7 ⁄16
8 6
6 1
1230
19
17
2604
HSS
60
36
80 5 ⁄8
41
5 ⁄16
34 5 ⁄1
6 68
5 ⁄8
17
15
9 10
3 ⁄4
19
55 3 ⁄8
37
3 ⁄8
23
26
18 11
⁄16
13 1 ⁄1
6 8
6 6
1 1 ⁄2
15
60
2659
37
58H
SS 8
0 42
87
3 ⁄4
44 7 ⁄8
37
7 ⁄8
75 3 ⁄4
19
17
10
1 ⁄2
12 3 ⁄8
21
61
3 ⁄8
40 3 ⁄8
26
29
18
11⁄16
15
11⁄16
10
8
6 1
1 ⁄2
2180
38
23
5467
HSS
100
48
94
7 ⁄8
48 7 ⁄1
6 41
7 ⁄16
82 7 ⁄8
19
18
12
13
3 ⁄8
23
67 3 ⁄8
43
3 ⁄8
29
32
18 11
⁄16
18 1 ⁄4
10
8
8 1
1 ⁄2
2680
50
12
7345
HSS
150
54
93
3 ⁄4
47 7 ⁄8
40
7 ⁄8
81 3 ⁄4
17
16
13
1 ⁄2
12 3 ⁄8
21
72
3 ⁄8
46 3 ⁄8
32
35
19
7 ⁄8
20 7 ⁄8
12
8
10
2 34
80
6365
92
50
MO
DE
LD
RY
AB
QC
RD
HI
JK
LM
NP
ST
UV
WE
FG
DIM
EN
SIO
NS
IN IN
CH
ES
INTE
RFA
CE
SIZ
ES
OP
ER
-A
TIN
GFL
OO
DE
D
WE
IGH
TS IN
PO
UN
DS
SIZED FOR APPLICATION
HSS
200
60
10
2 7 ⁄8
52
7 ⁄16
45 7 ⁄1
6 90
7 ⁄8
22
16
15
14 1 ⁄2
24
3 ⁄8
79 3 ⁄8
49
3 ⁄8
35
38
19 7 ⁄8
23
11⁄16
14
10
12
2
4,54
0 8,
489
12,4
38H
SS 2
50
66
111
7 ⁄8
56 15
⁄16
49 15
⁄16
99 7 ⁄8
25
17
16
1 ⁄2
16 3 ⁄4
27
3 ⁄8
85 3 ⁄8
52
3 ⁄8
38
41
19 7 ⁄8
26
5 ⁄16
16
12
14
2 5,
440
10,6
97 1
5,95
5H
SS 3
00
72
120
7 ⁄8
61 7 ⁄1
6 54
7 ⁄16
108
7 ⁄8
28
18
18
18
3 ⁄4
30 3 ⁄8
91
3 ⁄8
55 3 ⁄8
41
44
24
1 ⁄4
28 7 ⁄8
18
14
16
3
6,86
0 13
,696
20,
533
HSS
400
78
13
7 7 ⁄8
69
7 ⁄16
62 15
⁄16
125
7 ⁄8
35
21
19 1 ⁄2
22
7 ⁄8
37 3 ⁄8
97
3 ⁄8
58 3 ⁄8
44
47
24
1 ⁄4
31 1 ⁄2
20
16
18
3
9,06
0 18
,421
27,
783
HSS
500
84
15
3
77
1 ⁄2
70 1 ⁄2
14
1
42
28
21
26 3 ⁄4
38
3 ⁄8
103
3 ⁄8
61 3
/8
47
50
24 1 ⁄4
34
1 ⁄16
20
18
20
3
10
,780
23,
202
35,6
25
MO
DE
LD
RY
AB
QC
RD
HI
JK
LM
NP
ST
UV
WE
FG
DIM
EN
SIO
NS
IN IN
CH
ES
INTE
RFA
CE
SIZ
ES
OP
ER
-A
TIN
GFL
OO
DE
D
WE
IGH
TS IN
PO
UN
DS
SIZED FOR APPLICATION
1*
4" ty
pica
l 2*
1"
3*
3"
1*
5" ty
pica
l 2*
11 ⁄8
"
3*
37 ⁄8
"
DRAWING NOTES
MAXIM SILENCERS, INC. Rev. 12.01.08
HSS
NO
TES:
• Design pressure: 165 psi• Design temperature: -20 to 500 °F• Operating pressure range: 10 to 150 psig• Maximum safety valve settings: 165 psig• Tolerance on all dimensions ± ¼" unless otherwise specified• Dimensions not guaranteed unless certified• Connections 3" and larger are flanged ANSI 150# RF unless otherwise specified• Flange bolt holes straddle centerlines• Exterior painted with (1) shop coat high temperature black• Control items may be removed for shipment• Responsibility for installation is assumed by purchaser• Vessel must be insulated for heat retention
CO
NTR
OLS
:O
PTI
ON
S:
• Thermal insulation• Feed valve block and bypass manifold• Other support arrangements
A Steam and water inlet – S x 150# ANSI RF flangeB Water outlet – T x 150# ANSI RF flangeC Steam outlet – U x 150# ANSI RF flangeD Feed water inlet – V FNPTE Safety valve(s) outlet – WF Surface blowoff – 1" MNPTG Bottom blowdown – 1" MNPTH Pressure conn – ¼" FNPT (plugged)I Drain valve – ¼" FNPTJ Drain valve – FNPTK Drain valve – 1" FNPTL Test gauge conn – ¼ FNPT (plugged)IN
TER
FAC
E P
OIN
TS:
1 Level controller (pneumatic modulating)2 Air actuated feed water valve (not shown) mounts by others3 Level alarm sensor; relay panel (not shown) mounts by others4 Water gauge5 Pressure gauge6 Manual air vent valve7 Isolation valve8 Drain valve9 Safety valve(s)
10 Automatic air vent11 Surface blowoff valve12 Bottom blowdown valve13 Feed stop valve14 Feed check valve15 Isolation valve