Download - Specimen Guide for Peritoneal Dialysis Fluid TestingSpecimen Guide for Peritoneal Dialysis Fluid Testing Purpose: Indicates adequacy of dialysis Specimen Requirements: • Serum: BUN,

Transcript
Page 1: Specimen Guide for Peritoneal Dialysis Fluid TestingSpecimen Guide for Peritoneal Dialysis Fluid Testing Purpose: Indicates adequacy of dialysis Specimen Requirements: • Serum: BUN,

Specimen Guide for Peritoneal Dialysis Fluid Testing

Purpose:Indicates adequacy of dialysis

Specimen Requirements:• Serum:BUN,Creatinine-SST• PDFluid:Creatinine,Glucose, UreaNitrogen -YellowConicalTube-Timed 24Hr.• Urine:ResidualRenalFunction (Creatinine&UreaClearances) -YellowConicalTube-Timed 24Hr.(ifavailable)Shipping Requirements:Refrigerateallsamplespriortoshipment.Be suretoshipallsampleswithicepacks.

PD Kt/V, CREATININE CLEARANCE PD FLUID TESTING

Purpose:Chemistrytestingofrandom,overnightPDFluid

Specimen Requirements:• PDFluid:Creatinine, Glucose,UreaNitrogen,Total Protein,Sodium -YellowConicalTubeShipping Requirements:Refrigerateallsamplespriortoshipment.Be suretoshipallsampleswithicepacks.

PERITONEAL EQUILIBRATION TEST (PET) PERITONEAL FUNCTION TEST (PFT) (No calculations)Specimen Requirements:• Serum:BUN,Creatinine, Glucose,TotalProtein, Albumin-SST• PDFluid:Creatinine,Glucose, Urea,TotalProtein (foreachofthe6bagsplus QAbagPDFluid) -YellowConicalTube• Urine:Creatinine,UreaNitrogen -YellowConicalTubeShipping Requirements:Refrigerateallsamplespriortoshipment.Be suretoshipallsampleswithicepacks.

Urine Collection Devices

Use:Female/Maleurinecollectiondevicesfortimedspecimen

Note:Keepallcollectedurinerefrigeratedduringcollectiontime.

URINE COLLECTION AND TRANSPORT KIT

Use:PDFluid,UrineChemistryPreparation:Affixauniquebarcodetotheyellowtopconicaltube.Transfercollectedspecimentoyellowtopconicaltube.Refrigerate(36º-46ºF).Sendonlytheyellowtopconicaltubeanddisposeofcollectioncupasacontaminatedsharp.Shipping Requirements:Placeyellowtopconicaltubeindiagnosticspecimentrayandshipwithotherspecimens.

BD, BD Logo and all other trademarks are the property of Becton, Dickinson and Company.

© 2009 Fresenius Medical Care Holdings, Inc. All rights reserved.

Spectra and the Spectra logo are trademarks of Fresenius Medical Care Holdings, Inc. or its

affiliated companies. All other trademarks are the property of their respective owners.

POSTPD Rev. 8/09

525SycamoreDrive•Milpitas,CA95035•800-433-37738KingRoad•Rockleigh,NJ07647•800-522-4662www.spectra-labs.com

URINE HAT & URINE JUG

Purpose:TodeterminesolutetransportandUFcharacteristicsofperitonealmembrane.ReportincludesD/P&D/D0ratiosandinterpretations.Ifrequested,measuresureanitrogentransportcharacteristicsorlossofproteinacrosstheperitonealmembrane.

Specimen Requirements:• Serum:Glucose,Creatinine, and/orBUN,TotalProtein, Sodium-SST• PDFluid:Creatinine,Glucose, (and/orUrea,TotalProtein) -YellowConicalTubeat0Hr. -YellowConicalTubeat2Hr. -YellowConicalTubeat4Hr.

Fast PET Only:• Serum:Creatinine,Glucose -SST• PDFluid:Creatinine,Glucose -YellowConicalTubeat4Hr.Shipping Requirements:Refrigerateallsamplespriortoshipment.Be suretoshipallsampleswithicepacks.